recent developments in light detection

35
Recent Developments In Light Detection Konstantinos Nikolopoulos University of Athens Experimental Methods I, 4 th July 2005 Not Final Version

Upload: selene

Post on 18-Jan-2016

34 views

Category:

Documents


0 download

DESCRIPTION

Recent Developments In Light Detection. Konstantinos Nikolopoulos University of Athens Experimental Methods I, 4 th July 2005. Not Final Version. Pierre Auger Prototype Fluorescence telescope camera (440 photomultiplier tubes). Super – Kamiokande 20- inch PMT tube (Venetian Blind). - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Recent Developments  In Light Detection

Recent Developments In Light Detection

Konstantinos NikolopoulosUniversity of Athens

Experimental Methods I, 4th July 2005

Not F

inal V

ersio

n

Page 2: Recent Developments  In Light Detection

2K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Why detect light? Usage of Light detection in High Energy Physics*

Light is used in many aspects of HEP experiments• Calorimetry • Tracking

– Scintillating Fiber Trackers

• Particle Identification – Cherenkov

• Medical Imaging – PET– SPECT

Light Detectors are used in enormous numbers at HEP• Super – Kamiokande

– Cherenkov Counters 13.000 PMTs

• Pierre Auger Observatory– Fluoresence Detectors 10.560 PMTs

Light detection is crucial for every kind of high energy physics experiment.

Aim of this presentation is summarize current trends in light detection

Super – Kamiokande 20- inch PMT tube (Venetian Blind)Super – Kamiokande 20- inch PMT tube (Venetian Blind)

*short list of indicative examples

Pierre Auger Pierre Auger Prototype Fluorescence telescope Prototype Fluorescence telescope camera (440 photomultiplier tubes) camera (440 photomultiplier tubes)

Page 3: Recent Developments  In Light Detection

3K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Physics of Light Detection• Photoelectric Effect

– When a photon impinges on the surface of any material, it can liberate an electron provided that the photon energy is higher than the photoelectric workfunction Φ. The liberated electron carries kinetic energy W=hν-Φ, which can be sufficient to bring the electron not only from the surface, but also from the volume of the material to the free space.

– Semiconductors have a very small workfunction Φ.

• Electron lift from Valence Band to Conduction Band in a Semiconductor– When an photon impinges on a semiconductor, then an electron from the

valance band can be lifted to the conduction band. When the electron cannot recombine with the hole, due to the electric field of a silicon photodiode, it can be collected and the signal amplified.

The second process is far more efficient in light detection both in terms of detection efficiency and wavelength sensitivity, because it needs less energy O(1 eV) than the photoelectric effect one O(10 eV).

Page 4: Recent Developments  In Light Detection

4K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Main Characteristics of Light Detectors• Quantum Efficiency

– The efficiency in single photon detection

• Gain – Multiplication of the initial signal

• Sensitivity – Minimum # of photons required for output signal

• High – Voltage Supply• Timing and Positioning

– Capability of providing time and position information of the incoming photon

• Noise– Dark current– Nuclear counter effect (=The extra amount of charge produced in the photodiode by a

charged particle directly hitting it, on the top of the charge produced by th scintillation light).

• Experimental Conditions– B-field, Temperature, Radiation Levels, Particle Rate, e.t.c.

• Complexity of construction– Physical Shapes of Detectors– Price

Page 5: Recent Developments  In Light Detection

5K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Types of Light Detectors

• Vacuum Devices• Solid – State Devices

• Hybrid Devices• Gaseous Detectors

Page 6: Recent Developments  In Light Detection

6K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Vacuum Devices

Features:• Low noise amplification

– Due to the dynode – chain amplification scheme. Only noise contribution is the stochastic nature of the secondary e- emission

• High Gain O(106) – Output read by standard electronics No need for amplification No additional noise

– Gain = f(# dynodes)

• Good Energy resolution – Calorimeters with scintillating crystals

• Single photon detection

The first photoelectric tube was produced by Elster and Geiter in 1913. The first photomultiplier tube was invented by the RCA laboratories in 1936.

Page 7: Recent Developments  In Light Detection

7K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Many dynode chain design exists, with different properties!• Linear Focused Type

– Fast Response– Linearity– Large Output Current

• Box - and - Grid Type – Consist of a series of quarter cylindrical dynodes.– Electron collection efficiency– Uniformity

• Circular Cage Type– Compactness– Fast Response– High gain (with relatively low High—Voltage)

• Venetian Blind Type– Large dynode area (large photocathode area)– Uniformity– Large Output current

Vacuum Devices II

Circular Cage Circular Cage

Linear Focused Linear Focused

Box – and – gridBox – and – grid

Venetian BlindVenetian Blind

Page 8: Recent Developments  In Light Detection

8K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Vacuum Devices III

Drawbacks:• Q.E. typically constrained to ≈25%

– Reflection of photons by the glass of the window– Passage of photons through the photocathode without interaction– The produced photoelectrons may stop inside the cathode material

• Shape dictated by technical restrictions in the fabrication of the vacuum container

– Hand work involved Expensive to construct

• Very sensitive to B – field– Defocusing of the e-

Page 9: Recent Developments  In Light Detection

9K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Further Innovations in Vacuum Devices

• Sensitivity to B—field– Dynodes from meshes with small distance O(1mm) and high field between them.

• Information on the position of the incoming photons– Metal – channel devices. The single dynode chain is replaced by many chains in

parallel and there is a segmented anode.

• New photocathode and window materials

Metal – Channel DeviceMetal – Channel Device

Mesh DynodesMesh Dynodes

Page 10: Recent Developments  In Light Detection

10

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Solid – State Devices

Photosensors made of semiconductor material gained much attention in recent years.

• High Q.E.– Main negative contribution is the reflection at the surface

• Insensitivity to magnetic fields– Theoretical Limit ≈ 15 T

• Produced in standard fully – automated processes– Inexpensive

• Fairly easy to be tailored for individual needs– In short time

• Low mass• Small space consumption

– Thickness < 1/2 mm

They open new areas of application!

Page 11: Recent Developments  In Light Detection

11

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

PIN Photodiode• The PIN photodiode is a semiconductor device, typically

fabricated using doped silicon. In a photodiode, absorption of an incoming photon produces a single electron-hole pair. A small electric field within the photodiode causes these charge carriers to migrate in opposite directions towards external electrodes. This results in a measurable current or voltage, which has a linear relationship to the incident light flux.

• The silicon PIN diode is a very successful device. All major experiments in high-energy physics used it in big numbers in the last 2 decades. The operation is simple and reliable but since it has no gain it needs a charge-sensitive amplifier that adds to the cost and creates noise in the readout system. Single photon detection with silicon photodiodes is therefore not possible and the very good timing properties (1–2 ns) are destroyed by the signal rise time of the amplifier which is 10 ns or more.

• Arrays of photodiodes are easy to produce and are commercially available

Page 12: Recent Developments  In Light Detection

12

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Schematic Diagram of an APDSchematic Diagram of an APD

Avalanche Photodiodes

• Avalanche Photodiodes provide gain due to the high internal field at the junction of positively and negatively doped silicon.

– The incoming photon produces an e-h pair.– The electron gain enough energy due to the high internal

field to produce secondary electrons by impact ionization– An electron avalanche is created

• Gain is 50 – 200. – Higher gains (up to 104) can achieved

• Q.E. is of O(80%).• Large Dynamic range• Excellent energy resolution• Position information

– Only with dedicated setup position resolution O(0.3mm)

• Drawback: Very stable environment of operation needed for gains over a few hundreds.

– 1% gain variation δT= 0.1 K or δV/V=10-4 Hamamatsu S8148Hamamatsu S8148

Page 13: Recent Developments  In Light Detection

13

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Avalanche Photodiodes in Geiger Mode

• In this case the APD is operated at a bias voltage higher than the breakdown voltage.

• Any photon or thermally liberated electron starts an avalanche.• The avalanche persists until the voltage is lowered actively or when

the voltage drops on a properly chosen serial resistance.• The output signal is proportional to the over – voltage and the

capacitance of the APD.• Drawback: There is a long dead time O(1 ms) after each

breakdown.

Page 14: Recent Developments  In Light Detection

14

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Silicon Photomultipliers (SiPM)

• The SiPM is a novel type of APD.• It is a multipixel silicon photodiode with a number of micropixels of

size O(20 μm) joined together on common substrate and working on common load.

• The operational bias voltage is ≈15% higher than the breakdown voltage.

– The pixels are electrically decoupled from each other. – Each SiPM pixel operates in Geiger mode

• Each SiPM pixel operates as a binary device• The SiPM as a whole is an analogue detector.

The SiPM intend to solve the problem of long dead time in the APDs functioning in Geiger mode.

Page 15: Recent Developments  In Light Detection

15

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Single Photon Detection Efficiency of a SiPM, a APD Single Photon Detection Efficiency of a SiPM, a APD and a classical PMTand a classical PMT

Silicon Photomultipliers II

• Detection efficiency. – Q.E. is of O(80%).

– εgeometrical=Ssensitive/Stotal, is of O(25%).

• Gain O(106) – Independent of primary carrier number.

• Excellent energy resolution.

• Dynamic range O(10^3/mm^2).– <#photons/pixel> << 1 (signal saturation)

• Electronics noise is negligibly small– High gain

– Electronic noise contribution < 0.1 e-

• Main noise contribution is the dark rate.– Originates from carriers created thermally in sensitive volume or due to effects of high

electric fields.

– O(1 MHz/mm2) @ room temperature

– ≈1kHz/mm2 @ 100 K

– However, dark rate limits SiPM performance only in detection of very small light intensities O(1 ph.e.).

Page 16: Recent Developments  In Light Detection

16

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Response of SiPM to light of very low Response of SiPM to light of very low intensity. The number of photons can intensity. The number of photons can

be counted for each event.be counted for each event.

Silicon Photomultipliers (SiPM) III

• Insensitive to B – fields• Excellent time resolution (≈100 ns) for single

photo – electron detection– Time Resolution obeys the Poissonian law of

1/√Npixelsfired

• Fast rise time ≈1ns– The discharge is contained within a limited region in

the depletion zone (due to the voltage distribution) small duration

• Does not suffer from nuclear counter effects • Stable operation in room temperature

– Low gain variation with temperature– ΔΤ = 2.5 Κ for 1% gain variation.

• Does not exhibit any serious radiation damage

– Perhaps Neutrons are an exception to this rule

Page 17: Recent Developments  In Light Detection

17

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Simulated potential Simulated potential distribution and electron distribution and electron

trajectorytrajectory

Schematic view of the Pixel HPDSchematic view of the Pixel HPD

Hybrid Detectors (HPD)

• These detectors combine the advantages of the vacuum devices and the solid – state devices

– Pixel – HPD– Pad – HPD

• The vacuum container and the photocathode are the same as in the classical PMT.

• The photo – electrons are accelerated in a high electric field and are focused onto an anode:

– A silicon PIN photodiode, an amplification of 4000 is achieved with an electric field of 15kV.

– An APD, a gain of more than 105 can be achieved, allowing usage of simple readout electronic circuit.

Page 18: Recent Developments  In Light Detection

18

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Hybrid Detectors (HPD) II

• Q.E. is of O(20%) @ 270 – 400 nm

• εgeometrical is of O(80%).– Using electron optics.

• Position information– When the anode is segmented.

• The HPDs have a very good energy resolution, even for light of very low intensity.

Typical photoelectron spectrumTypical photoelectron spectrum

Page 19: Recent Developments  In Light Detection

19

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Electric Field profile in a VLPCElectric Field profile in a VLPCSchematic Layout of a VLPCSchematic Layout of a VLPC

Visible Light Photon Counters (VLPC)

• The operation principle of VLPCs is the effect of impurity band. – Occurs when a semiconductor is heavily doped with shallow donors or acceptors.

– The impurity atoms are close together electrical transport occuring by charge hopping from impurity site to impurity site!

• The standard 1.12 eV gap of Si is used to absorb photons

• The small gap with the impurity band is used for creating an electron – D+ avalanche multiplication.

– Small gap O(0.05eV) Relatively low field is required for avalanche the required field for producing an avalanche is low.

– Localized and self– limiting avalanche(due to local field collapse, D+ have low mobility)

• The drift region can been seen as an internal resistor in series with an ideal VLPC

VLPCs are solid state photo – detectors, originally invented at Rockwell International and presently developed and manufactured by Boeing.

Page 20: Recent Developments  In Light Detection

20

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Visible Light Photon Counters II

• High Q.E. (80%).• High gain O(5* 10^4).• Low gain dispersion.• Operational in a high background radiation enviroment.• Drawback: Cryogenic temperatures needed!

– In order to freeze out the intrinsic carriers!

VLPC Single Photoelectron VLPC Single Photoelectron counting capabilitiescounting capabilities

Page 21: Recent Developments  In Light Detection

21

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Gaseous Detectors• These detectors have been developed for cases that large areas

are needed to be covered.• Their functionality principle relies on photo – conversion and

subsequent multiplication in a gas avalanche.• The photo--conversion can be in the gas itself or in a CsI

photocathode, which can be made in large areas.• Readout: MWPC e.t.c.

Page 22: Recent Developments  In Light Detection

22

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Gaseous Detectors II

• Main problem: Ion and photon feedback– Ion Feedback, ionization of the residual gas (Vacuum)

or the gas used (gaseous detectors) in the detector. Collision of the gas molecules with electrons can cause the ionization of the gas then a pulse can be created

– Positive ions striking the front dynodes or the photocathode may produce many secondary electrons large noise pulse

– This new pulse usually follows a true photo –electric pulse after pulsing

• Solved to some extent by “the gas electron multiplier (GEM) foil” technique

Field Distribution in the Gas – Field Distribution in the Gas – Electron Multiplier foilElectron Multiplier foil

Page 23: Recent Developments  In Light Detection

23

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

The ATLAS detectorThe ATLAS detector

The ATLAS Tile Calorimeter

• A Torodial LHC ApparatuS is general purpose detector to study proton – proton collisions @ √s=14 TeV (some Heavy – Ions Program is foreseen as well)

• ATLAS is mostly known for its Muon System, however as a general purpose apparatus, ATLAS should be able to perform accurate calorimetry as well.

• The ATLAS calorimetry system is quite complicated, incorporating different approaches

– Liquid Argon Sampling Electromagnetic Calorimeter |η|<3.2– Liquid Argon Hadronic Calorimeter 1.5<|η|<3.2– Tile Hadronic Calorimeter |η|<1.7– Forward Calorimeter 3.2<|n|<4.9 (Liquid Argon)

ATLAS Tile Calorimeter Schematic LayoutATLAS Tile Calorimeter Schematic Layout

Page 24: Recent Developments  In Light Detection

24

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

The ATLAS Tile Calorimeter II

• Tile Calorimeter– Active medium: Tiles of polysterene (emission

maximum ≈100 nm)

– Absorber :Steel

– Wavelength Shifter Fibers (≈100nm ≈400nm)

– Photo – Multiplier Tubes (10.500) (max sensitivity ≈420nm)

• PMT characteristics– Min/Max wavelength = 300nm/650nm

– Max sensitivity @ 420nm

– Window : Borosilicate

– Photocathode : Bialkali

– Gain = 3 105

– Dark Current = 2 nA

– Rise Time = 1.5 ns

– Transit Time = 7 ns

– Transit Time Spread = 0.26 ns

– Number of dynodes = 8

– Operation Voltage = 800 Volt

Tile Calorimeter: Operation PrincipleTile Calorimeter: Operation Principle

ATLAS polysterene tilesATLAS polysterene tiles

Page 25: Recent Developments  In Light Detection

25

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

The KLOE Electromagnetic Calorimeter

• The main aim of KLOE is to do high precision CP – Violation studies in K0 decays a the Frascati Φ – Factory DAFNE.

• The Electromagnetic Calorimeter– Sampling calorimeter: Scintillating Fibers are glued inside thin grooved lead layers.

Volume ratio of the composite Pb:scint:glue of 42:48:10 and X0 =1.5 cm.

– Total depth is 23 cm (15 X0) . Containment: 98% of 500 MeV e/m showers (Maximum shower energy at KLOE).

• Scintillating fibers – Excellent time resolution for long detectors.– Relatively long attenuation lenght – Total fibers lenght is 15000 Km!

• PMTs with Mesh dynodes are used– E/M Calorimeter inside B-field.– B- filed strength ≈0.1-0.2 T at the readout.– The total number of PMTs is 4880.

KLOE Electromagnetic Calorimeter

ππ00 mass reconstruction using KLOE’s mass reconstruction using KLOE’s calorimetercalorimeter

Page 26: Recent Developments  In Light Detection

26

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Schematic layout of the Schematic layout of the CMS ECALCMS ECAL

The CMS Electromagnetic Calorimeter

• CMS is a general purpose detector for the Large Hadron Collider

• CMS Electromagnetic Calorimeter– Homogenous calorimeter

– 75.000 PbW04 scintillating crystals used.

– Calorimeter dimensions:

Longitudinal 25 X0 = 22.2 cm

Transverse 1 RM = 2.2 cm– Operation in high B-field 4T– Very High radiation leves– One APD mounted on each side of the crystal depth

of interaction.(Sufficient pulse height from the APDs)

• Many sources to be kept under control:– Longitudinal uniformity of light collection– Strong light yield variation with temperature (-2.3%/0C)– APD gain variation with applied tension (-3%/Volt) and

termperature (-2.3%/0C)– Light collection uniformity– light transmission due to radiation damage– Leakage front and rear Energy Resolution measured with 180 GeV Energy Resolution measured with 180 GeV

electrons in 3x3 crystal matrix with 2 electrons in 3x3 crystal matrix with 2 APDs/crystal readoutAPDs/crystal readout

The CMS apparatusThe CMS apparatus

The PbW04 scintillating crystals used by The PbW04 scintillating crystals used by CMS ECalCMS ECal

Page 27: Recent Developments  In Light Detection

27

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

LHCb Ring Imaging Cherenkov

• LHCb is a single arm forward spectrometer designed to perform various B – physics measurements in the LHC.

• 2 Ring Imaging Cherenkovs– RICH 1 Aerogel n =1.03 ( 2 – 10 GeV)

C4F10 n =1.0014 (10 – 60 GeV)

– RICH 2 CF4 n =1.0005 (16 – 100 GeV)

– HPDs 61 pixel/HPD– Magnetic Field, High Radiation Dose

Cherenkov rings produced by 120 GeV Cherenkov rings produced by 120 GeV ππ--, ,

radiator Cradiator C44FF10 .10 .The circle is guide to the eye.The circle is guide to the eye.

LCHb Schematic LayoutLCHb Schematic Layout

Typical Event from RICH1Typical Event from RICH1Schematic Layout of RICH1Schematic Layout of RICH1

Page 28: Recent Developments  In Light Detection

28

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

The D0 SciFi Tracker

• D0 is a general purpose apparatus to study √s=2 TeV proton – antiproton collisions at Tevatron.

• Central Scintillating Fiber Tracker – Consists of 74.000 multi – clad scintillating fibers– refraction index 1.591.491.42 for improvement of

light trapping

• VLPCs– Q.E. 70%,– Gain 20.000– Rate capability > 10 MHz– Noise Rate <0.1 %– Impurity band 0.05 below the conduction band– Operation at 9K

VLPC waferVLPC wafer

Schematic view of the D0 apparatusSchematic view of the D0 apparatus

Page 29: Recent Developments  In Light Detection

29

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

The GlueX Barrel Electromagnetic Calorimeter

• The goal of the GlueX experiment at Jefferson Laboratory is to search for gluonic excitations manifested in exotic hybrid vector mesons with masses up to 2.5 GeV, using linearly polarized photons of 8 – 10 GeV energy.

• Electromagnetic Barrel Calorimeter– Sampling calorimeter– Scintillating fiber

Layout of the GlueX apparatusLayout of the GlueX apparatus

Page 30: Recent Developments  In Light Detection

30

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

ConclusionsPMT APD HPD SiPM

γ- Detection Efficiency

Blue 20% 50% 20% 12%

Green –yellow A few % 60 – 70% A few % 15%

Red <1% 80% <1% 15%

Gain 106-107 100 - 200 103 106

High – Voltage 1-2 kV 100 – 500 V 20 kV 25 V

Operation in B-field problematic O.K. O.K. O.K.

Threshold Sensitivity S/N>>1

1 ph.e. ≈10 ph.e. 1 ph.e. 1 ph.e.

Timing / 10 ph.e. ≈100 ps A few ns ≈100 ps 30 ps

Dynamic Range ≈106 large large ≈103/mm2

Complexity High (vacuum,HV)

Medium (low noise electronics)

Very High(hybrid technology,

very HV)

Relatively low

Page 31: Recent Developments  In Light Detection

31

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Conclusions (continued)

As concluding remarks we would like to focus on the following:• Light detection is crucial for every kind of High Energy Physics

experiment. – One should also note that we didn’t mention at all a very closely related topic,

that of light detection for medical purposes (PET e.t.c.).

• The progress in the field of light detection is enormous. Today, the market offers light detectors for almost every need and funding.

• Semiconductor devices are a very promising development in the field. It is expected to be further improved.

• Further progress in the field can be expected.

Page 32: Recent Developments  In Light Detection

32

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

ReferencesGeneral• D. Renker, Photosensors, Nucl. Instr. And Meth. A 527 (2004), p.15• Hamamatsu Photonics , http://www.hamamatsu.com/

Vacuum Devices• Hamamatsu Photonics, Photomultiplier Tubes (PMTs) – Construction and Operating Characteristics, http://www.hpk.co.jp/APDs• I. Britvitch et al., Avalanche photodiodes now and possible developments, Nucl. Instr. And Meth. A 535 (2004), p.523SiPMHPDE. Albrecht et al., Nucl. Instr. And Meth. A 442 (2000), p.164L. Somerville, Pixel hybrid photon detectors for the ring imaging Cherenkov, Nucl. Instr. And Meth. A 546 (2005), p.81A. Braem et al., Nucl. Instr. And Meth. A 504 (2003), p.19

VLPCs• M.D. Petroff, et al., Appl. Phys. Lett. 51 (1987) p. 406

A. Bross et al., Nucl. Instr. And Meth. A 477 (2002), p.172

GaseousExperiments• The ATLAS experiment, http://atlas.web.cern.ch/Atlas/• The CMS experiment, http://cmsinfo.cern.ch/Welcome.html/• The LHCb experiment, http://lhcb.web.cern.ch/lhcb/• The KLOE experiment, http://www.lnf.infn.it/kloe/• The D0 experiment, http://www-d0.fnal.gov/• The GlueX experiment, http://www.gluex.org/• The Pierre Auger Obervatory, http://www.auger.org/• Super-Kamiokande, US Collaboration homepage, http://neutrino.phys.washington.edu/~superk/

Page 33: Recent Developments  In Light Detection

33

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Back-

Up Slid

es

Page 34: Recent Developments  In Light Detection

34

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

• PET produces images of the body by detecting the radiation emitted from radioactive substances. These substances are injected into the body, and are usually tagged with a radioactive atom, such as (C-11, F-18, O-15, or N-13), that has a short decay time. (bombardment of normal chemicals with neutrons)

• PET detects the gamma rays given off at the site where a positron emitted from the radioactive substance collides with an electron in the tissue.

• PET provides images of blood flow or other biochemical functions, depending upon the type of molecule that is radioactively tagged. For example, PET can show images of glucose metabolism in the brain, or rapid changes in activity in various areas of the body. However, there are few PET centers in the country because they must be located near a particle accelerator device that produces the short-lived radioisotopes used in the technique.

Positron Emission Tomography

Schematic of a PET scannerSchematic of a PET scanner

Page 35: Recent Developments  In Light Detection

35

K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005K. Nikolopoulos (Univ. of Athens) – Recent Developments in Light Detection – July 4 th 2005

Single Photon Emission Computed Tomography

• Single Photon Emission Computed Tomography (SPECT)SPECT is a technique similar to PET.

– The radioactive substances (Xenon-133, Technetium-99, Iodine-123) have longer decay times than those used in PET

– Single photon emittance instead of double gamma rays.

• SPECT can provide information about blood flow and the distribution of radioactive substances in the body.

• Its images have less sensitivity and are less detailed than PET images.

• SPECT technique is less expensive than PET. • SPECT centers are more accessible than PET centers because

they do not have to be located near a particle accelerator.