reach-in unit coolers - refplusrefplus.com/wp-content/uploads/2016/02/es-ed-ec-ew-1.pdf · 3 esa /...
TRANSCRIPT
![Page 1: REACH-IN UNIT COOLERS - Refplusrefplus.com/wp-content/uploads/2016/02/es-ed-ec-ew-1.pdf · 3 esa / ese wiring diagrams - air and electric defrost capacity fan motors unit dimensions](https://reader030.vdocuments.us/reader030/viewer/2022012318/5a7878747f8b9a1f128b75e0/html5/thumbnails/1.jpg)
FOR COOLERS ABOVE +34ºF• Top or wall mounted compact units from 1,000 to 1,500 BTU/HR./10ºF TD
EWA
ECA
FOR COOLERS ABOVE +34ºF• Wall or mullion mounted units from 1,300 to 2,300 BTU/HR./10ºF TD
FOR COOLERS ABOVE +34ºF• Top mounted single flow units from 1,000 to 5,500 BTU/HR./10ºF TD
FOR COOLERS ABOVE +34ºF• Top mounted dual flow units from 1,000 to 3,300 BTU/HR./10ºF TD
ESAFOR COOLERS AND FREEZER FROM -20ºC TO 34ºF• Top mounted single flow units from 1,000 to 5,500 BTU/HR./10ºF TD ESE
EDA
REACH-IN UNIT COOLERS
Certified ISO-9001
![Page 2: REACH-IN UNIT COOLERS - Refplusrefplus.com/wp-content/uploads/2016/02/es-ed-ec-ew-1.pdf · 3 esa / ese wiring diagrams - air and electric defrost capacity fan motors unit dimensions](https://reader030.vdocuments.us/reader030/viewer/2022012318/5a7878747f8b9a1f128b75e0/html5/thumbnails/2.jpg)
2
EDA / ECA / EWA
F°43+ EVOBA SRELOOC ROFTSORFED RIA - ADE
1/2 O.D.REMOVABLE DRAIN FITTING
1/4 DIA.
1/216 5/8
15 5/810 1/4 MAX
7 1/4
73/
4
AIR5
1/2
1/2
1/2 O.D.REMOVABLE DRAIN FITTING
AIR5 3/4
1 TYP.
1/4
1/2 TYP.D
2 7/8
181/
4
181/
2
91/
26
1/2
1/4 DIA4 MOUNTING HOLES
CAPACITY FAN MOTORS UNIT DIMENSIONS CONNECTIONS R-134A SHIPPINGTHGIEWGNITAREPO.TCUS.QIL)SEHCNI(V021).RH/UTB(CFMMODEL
8°F TD 10°F TD 12°F TD 15°F TD QTY FLA W H D A B F.N. O.D. CHARGE (LB.) (LB.)
MODEL CFM8°F TD 10°F TD 12°F TD 15°F TD QTY FLA
CAPACITY(BTU/HR.)
FAN MOTORS CONNECTIONS120V LIQ.
F.N.SUCT.O.D.
R-134AOPERATING
CHARGE (LB.)
SHIPPINGWEIGHT
(LB.)
CAPACITY FAN MOTORS UNIT DIMENSIONS CONNECTIONS R-134A SHIPPINGTHGIEWGNITAREPO.TCUS.QIL)SEHCNI(V021CFMMODEL
8°F TD 10°F TD 12°F TD 15°F TD QTY FLA D F.N. O.D. CHARGE (LB.) (LB.)(BTU/HR.)
06/1/042 rof 2 xiffus ,06/1/021 rof 1 xiffus esU•noitcus F°52 ta ropav %07 ,diuqil %03 no desab egrahc gnitarepO•05/1/022-002 rof 29.0 yb yticapac ylpitlum dna 2 xiffus esU•22-R rof trahc 431-R esU•
2 3/8 B 3 A4/
H
1
WDAIR
1/4 DIA4 MOUNTING HOLES
1/2 O.D.REMOVABLE DRAIN FITTING
1 3/4
ECA - AIR DEFROST FOR COOLERS ABOVE +34°F
EWA - AIR DEFROST FOR COOLERS ABOVE +34°F
EDA
ECA
EWA
EDA102-1 195 800 1,000 1,200 1,500 1 0.7 18 1/8 3 1/2 14 1/8 17 10 1/2 3/8 0.3 11.5 EDA132-1 185 1,040 1,300 1,560 1,950 1 0.7 18 1/8 3 1/2 14 1/8 17 10 1/2 3/8 0.4 12.5 EDA152-1 245 1,200 1,500 1,800 2,250 1 0.7 18 1/8 4 1/2 14 1/8 17 10 1/2 3/8 0.4 13.0 EDA182-1 225 1,440 1,800 2,160 2,700 1 0.7 18 1/8 4 1/2 14 1/8 17 10 1/2 3/8 0.6 14.0 EDA232-1 505 1,840 2,300 2,760 3,450 2 1.4 20 1/8 5 1/2 17 1/8 19 13 1/2 3/8 0.5 17.0 EDA282-1 450 2,240 2,800 3,360 4,200 2 1.4 20 1/8 5 1/2 17 1/8 19 13 1/2 3/8 0.7 18.5 EDA332-1 430 2,640 3,300 3,960 4,950 2 1.4 20 1/8 5 1/2 17 1/8 19 13 1/2 3/8 0.9 20.0
ECA101-1 220 800 1,000 1,200 1,500 1 0.7 1/2 3/8 0.3 10.5 ECA131-1 200 1,040 1,300 1,560 1,950 1 0.7 1/2 3/8 0.4 11.5 ECA151-1 190 1,200 1,500 1,800 2,250 1 0.7 1/2 3/8 0.6 12.5
EWA130-1 220 1,040 1,300 1,560 1,950 1 0.7 15 3/4 1/2 3/8 0.4 13.0 EWA180-1 200 1,440 1,800 2,160 2,700 1 0.7 15 3/4 1/2 3/8 0.6 14.0 EWA230-1 380 1,840 2,300 2,760 3,450 2 1.4 21 3/4 1/2 3/8 0.9 17.0
![Page 3: REACH-IN UNIT COOLERS - Refplusrefplus.com/wp-content/uploads/2016/02/es-ed-ec-ew-1.pdf · 3 esa / ese wiring diagrams - air and electric defrost capacity fan motors unit dimensions](https://reader030.vdocuments.us/reader030/viewer/2022012318/5a7878747f8b9a1f128b75e0/html5/thumbnails/3.jpg)
3
ESA / ESE
WIRING DIAGRAMS - AIR AND ELECTRIC DEFROST
CAPACITY FAN MOTORS UNIT DIMENSIONS CONNECTIONS R-134A SHIPPINGTHGIEWGNITAREPO.TCUS.QIL)SEHCNI(V021).RH/UTB(CFMMODEL
8°F TD 10°F TD 12°F TD 15°F TD QTY FLA W H D A B F.N. O.D. CHARGE (LB.) (LB.)
2 1/2
W
A
H
1 1/814 MOUNTING HOLES
1REMOVABLE DRAIN FITTING
AIR
DB
CAPACITY FAN MOTORS HEATERS UNIT DIMENSIONS CONNECTIONS R-134A SHIPPING.TCUS.QIL)SEHCNI(ALFV042V021
YTQ).RH/UTB(CFMMODEL OPERATING WEIGHT
-20°F 0°F +20°F FLA FLA KW 120V 240V W H D A B F.N. O.D. CHARGE (LB.) (LB.)
M : FAN MOTOR INTERNALLY PROTECTED:TERMINAL BLOCK: BY OTHERS
USE COPPER CONDUCTOR ONLY
M4120(240)/1/60
N
L1
M2M1 M3 M5
(L1)
(L2)
ESA
120 V 120 V 240V
DTFD: DEFROST TERMINATION FAN DELAY
M1: FAN MOTOR INTERNALLY PROTECTED
WTH: WALL THERMOSTATLS: LIQUID LINE SOLENOID
DT: DEFROST TIMER
TM: TIMER MOTOR
DH: DEFROST HEATER
HS: HEATER SAFETY
:TERMINAL BLOCK : BY OTHERS
WTH
3N
LS
4X
M2M1 M3
120(240)/1/60
1TM
DT
2N (L2)
L1(L1)
DH
ESE 182 TO 552
N
ESE 102 TO 152
H3 N H3 N
DH
ESE 182 TO 552
H3
DTFD
BLACK
BROWN
RED
M
X
3
4
N
USE COPPER CONDUCTOR ONLY
HS
H3
H2
ESE
F°43+ EVOBA SRELOOC ROFTSORFED RIA - ASE
ESE - ELECTRIC DEFROST FOR COOLERS AND FREEZERS FROM -20°F TO +34°F
ESA / ESE
ESA102-1 195 800 1,000 1,200 1,500 1 0.7 17 1/4 4 1/2 15 13 13 1/4 1/2 3/8 0.4 9.0 ESA132-1 185 1,040 1,300 1,560 1,950 1 0.7 17 1/4 4 1/2 15 13 13 1/4 1/2 3/8 0.5 10.0 ESA152-1 195 1,200 1,500 1,800 2,250 1 0.7 21 3/4 4 1/2 15 17 1/2 13 1/4 1/2 3/8 0.6 11.5 ESA182-1 225 1,440 1,800 2,160 2,700 1 0.7 25 3/4 4 1/2 15 21 1/2 13 1/4 1/2 3/8 0.7 13.0 ESA232-1 395 1,840 2,300 2,760 3,450 2 1.4 33 3/4 4 1/2 15 29 1/2 13 1/4 1/2 3/8 0.8 17.0 ESA282-1 385 2,240 2,800 3,360 4,200 2 1.4 33 3/4 4 1/2 15 29 1/2 13 1/4 1/2 3/8 0.9 18.5 ESA332-1 420 2,640 3,300 3,960 4,950 2 1.4 33 3/4 5 1/2 15 29 1/2 13 1/4 1/2 3/8 1.2 20.0 ESA452-1 625 3,600 4,500 5,400 6,750 3 2.1 43 3/4 5 1/2 17 39 1/2 15 1/4 1/2 1/2 1.5 27.5 ESA552-1 615 4,400 5,500 6,600 8,250 3 2.1 43 3/4 5 1/2 17 39 1/2 15 1/4 1/2 1/2 1.8 32.5
ESE102-1 195 850 925 1,000 1 0.7 NA 0.64 5.3 NA 17 1/4 4 1/2 15 13 13 1/4 1/2 3/8 0.6 9.0 ESE132-1 185 1,105 1,203 1,300 1 0.7 NA 0.64 5.3 NA 17 1/4 4 1/2 15 13 13 1/4 1/2 3/8 1.0 10.0 ESE152-1 195 1,275 1,388 1,500 1 0.7 NA 0.80 6.7 NA 21 3/4 4 1/2 15 17 1/2 13 1/4 1/2 3/8 1.3 11.5 ESE182-(1)(2) 225 1,530 1,665 1,800 1 0.7 0.42 0.96 8.0 4.0 25 3/4 4 1/2 15 21 1/2 13 1/4 1/2 3/8 1.0 13.0 ESE232-(1)(2) 395 1,955 2,128 2,300 2 1.4 0.84 1.28 10.7 5.3 33 3/4 4 1/2 15 29 1/2 13 1/4 1/2 3/8 1.5 17.0 ESE282-(1)(2) 385 2,380 2,590 2,800 2 1.4 0.84 1.28 10.7 5.3 33 3/4 4 1/2 15 29 1/2 13 1/4 1/2 3/8 2.0 18.5 ESE332-(1)(2) 420 2,805 3,053 3,300 2 1.4 0.84 1.28 10.7 5.3 33 3/4 5 1/2 15 29 1/2 13 1/4 1/2 3/8 2.5 20.0 ESE452-(1)(2) 625 3,825 4,163 4,500 3 2.1 1.26 1.60 13.3 6.7 43 3/4 5 1/2 17 39 1/2 15 1/4 1/2 3/8 2.9 27.5 ESE552-(1)(2) 615 4,675 5,088 5,500 3 2.1 1.26 1.60 13.3 6.7 43 3/4 5 1/2 17 39 1/2 15 1/4 1/2 3/8 3.6 32.5
![Page 4: REACH-IN UNIT COOLERS - Refplusrefplus.com/wp-content/uploads/2016/02/es-ed-ec-ew-1.pdf · 3 esa / ese wiring diagrams - air and electric defrost capacity fan motors unit dimensions](https://reader030.vdocuments.us/reader030/viewer/2022012318/5a7878747f8b9a1f128b75e0/html5/thumbnails/4.jpg)
APPLICATIONSESA, EDA, ECA, and EWA Models for coolers +34°F and above.ESE Models for coolers and freezers ranging from –20 to +34°F and above.
SPECIFICATIONSESA, ESE, and ECA Models are of a single coil construction for an air distribution directed towards the back of the cooler or the freezer. Fans draw air through the fan guards and discharge it through the evaporator coil on the back of the unit.
EDA Models are of a dual coil construction for an equal air distribution on both sides of the unit. The fans draw air upward through the fan guards and discharge it through each evaporator coil.
EWA Models are of a single coil construction for either up or down airflow and can be wall or mullion mounted. Stan-dard configuration is down flow and can be field modified to up flow.
ECA Models can be top or wall mounted, whereas ESA, EDA, and ESE Models are top mounted.
Coils are manufactured with seamless deoxidized heavy wall smooth copper tubes and aluminum plate fins. For a maximum heat transfer, tubes are mechanically expanded into self-spaced plate fins with full collar for a permanent bond. Connections and bends are brazed with high tem-perature brazing alloy. Coils are factory leak tested at 400 psig and purged with a –40°F dew point dry air. Coils are circuited for HCFC and HFC refrigerants.
The Reach-In Unit Cooler casings are heavy-gauge tex-tured aluminum with stainless steel or plated hardware for a light weight and corrosion-free assembly.
All units are provided with a removable 1/2” O.D. alumi-num drain fitting for easier installation and cleaning.
Heavy-duty fan motors are provided for long life and dependable service. They are permanently lubricated, thermally protected, and available for 120/1/60 or 208-240/1/60. Note: 208/240/1/60 volt motors can be used for 200-220/1/50.
For full protection of moving parts, fan blades and fan guards are injection-moulded polymer for corrosion protection and for consistency of dimensions.
All models are provided with a terminal block for easier field wi-ring. Terminals are clearly identified to match the wiring diagram supplied with the unit.
ESE Models are provided with a sealed non-adjustable fan delay/defrost termination thermostat and a heater safety thermostat. All units use incoloy, low-watt density, tubular heaters for a po-sitive defrost.
All Reach-In Unit Coolers are of a modular design using a mini-mum number of parts to simplify replacement and to reduce in-ventory.
REACH-IN UNIT COOLERS
ES-ED-EC-EW-02/2016-R0Refplus Inc. reserves the right to make any changes in the design or
specifications of any product at any time without notice. © Copyright 2016 by RefPlus Inc.
USA & CANADA 1-888-816-2665 / refplus.com2777 Grande-Allée,Saint-Hubert, Québec,Canada,J4T 2R4 T 450 641-2665 F 450 641-4554
ISO-9001