rcu510 description
DESCRIPTION
Remote controller unitTRANSCRIPT
![Page 1: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/1.jpg)
1
Kongsberg Maritime
RCU 510
Remote Controller UnitRCU 510
![Page 2: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/2.jpg)
2
Kongsberg Maritime
RCU510 Technical data
Remote Controller Unit (RCU) is a real-time single board computer and remote IO bus driver and IO handling controller.
RCU 510 is based on PowerPC Host Processor MPC 8245 running at 400MHz.
32 MByte SDRAM (133MHz), 16 Mbyte Flash memory.
![Page 3: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/3.jpg)
3
Kongsberg Maritime
RCU510 Interfaces
32 IO channels:
• Ch 1-16: DI, DO, AI, AO
• Ch 17-20: DI, DO, AI
• Ch 21-24: Relay outputs
• Ch 25-32: AI, AO
7 serial line interfaces (RS232/RS422/RS485)
Dual Ethernet LAN interface
SPBus interface to RIO400 modules
Dual CAN-bus interface
Dual Profibus interface
![Page 4: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/4.jpg)
4
Kongsberg Maritime
RCU 510 layout
Status leds
IO
IO
Ethernet AEthernet B
Profibus/CANbusAddress/mode setting
Console connection
NMI/Reset
IO
IO
7 x serial lines
SPBus
X1
X2
P4
P3
P6
X3
X4
X5
P2
![Page 5: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/5.jpg)
5
Kongsberg Maritime
RCU 510 start-up sequence
ST3, downmost
HW test
ST0ST1ST2ST3
Status LEDs
ST0, uppermost
![Page 6: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/6.jpg)
6
Kongsberg Maritime
RCU 510 connector X1-X4: IO connection and power
All 32 IO channels are connected via thefour X connectors.
Power to the RCU510 is providedthrough the four X connectors.The four power terminals areinterconnected on the circuit board.
RCU510
X1
X2
X3
X4
![Page 7: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/7.jpg)
7
Kongsberg Maritime
MODE0FE
DCB
A987654321
The hexadecimal MODE switch set SW-mode and is used only for advanced servicing and debugging purposes.
The switch
has to be set to 0
(Zero) for normal operation
RCU 510 MODE: Mode setting
S7: MAC1
S6: MAC2
S5: MAC3
S4: MODE
![Page 8: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/8.jpg)
8
Kongsberg Maritime
012345
6789ABCDEF
MAC1
MAC2
MAC3
MSD
LSD
012345
6789ABCDEF
012345
6789ABCDEF
Network A and B Internet Protocol addresses (IP-addresses) (SW address)
Example of IP address of RCU1:157.237.143.151 net A 157.236.143.151 net B
Network A and B MAC addresses (HW address)
Example of MAC address RCU1:02:41:4c:42:12:01 for net A02:41:4c:42:22:01 for net B
RCU 510 MAC1-3: Address setting
![Page 9: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/9.jpg)
9
Kongsberg Maritime
RCU 510 connector X1-X4: Loop Typicals
![Page 10: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/10.jpg)
10
Kongsberg Maritime
RCU 510 connector P4: Ethernet connection
Dual female RJ45 8 pin socket for 10Base-T/100Base-TX
Port A is above port B.
P4
![Page 11: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/11.jpg)
11
Kongsberg Maritime
RCU 510 connector X5: Serial lines
7 serial lines can be connected to X5.Each serial line can be configured as RS232, RS422 or RS485
X5
TBSS for serial line connection
![Page 12: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/12.jpg)
12
Kongsberg Maritime
RCU 510: Loop typical SL001
![Page 13: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/13.jpg)
13
Kongsberg Maritime
RCU 510 connector P6: Console connection
RS232 serial line for console connection P6
![Page 14: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/14.jpg)
14
Kongsberg Maritime
RCU 510 connector P2: SPBus
SPBus-TERM
RIO MODULES
SPBus-TERMor SPBus-Hub
RCU510
![Page 15: RCU510 Description](https://reader030.vdocuments.us/reader030/viewer/2022020320/55cf94e4550346f57ba51d3c/html5/thumbnails/15.jpg)
15
Kongsberg Maritime
RCU 510 connector P2: SPBus example
Drw:1002088