RCD Inspection Log Book

Upload: vannguyet

Post on 02-Mar-2019

218 views

Category:

Documents


0 download

TRANSCRIPT

RCD Inspection Log Book

RCD Inspection Log Book

2 © Clipsal Australia Pty Ltd

This book is the property of:

Date Commenced: / / .

Date Completed: / / .

Location

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

3© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

4 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

5© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

6 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

7© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

8 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

9© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

10 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

11© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

12 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

13© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

14 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

15© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

16 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

17© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

18 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

19© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

20 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

21© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

22 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

23© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

24 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

25© Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

26 © Clipsal Australia Pty Ltd

Test Device Used:

DateSerial No. Location

Results/Repairs Comments

Lic. No. Sig.

RCD Test Results RCD Inspection Log Book

27© Clipsal Australia Pty Ltd

Test Device Used:

RCD Test Results RCD Inspection Log Book

28 © Clipsal Australia Pty Ltd

TEST/INST. CHECKED LAB

RCD Inspection Log Book

29© Clipsal Australia Pty Ltd

Note: the following information is provided as a guide only. Refer to the appropriate standards for compliance.

AS/NZS 3760: 2003

Clause 2.3.3.4 Test for Operation of RCDs

When tested in accordance with Appendix D at intervals not exceeding those specified in Table 2, the maximum tripping time for RCDs shall not exceed the values shown in Table 1.

Notes:

1. The test for operating time using a.c. for Type A RCDs (a.c. and d.c. pulse sensitive) is acceptable as d.c. calibration is linked to a.c. calibration and verified by type test.

2. Portable RCDs which are permanently wired to terminals in equipment may be tested by push button only, observing the operating time, which should be without undue delay. In case of doubt, use an external timer circuit, capable of detecting the test current start and finish, to measure disconnect time of not more than 150mS for a 30mA unit and 40mS for a 10mA unit (the test button current is assumed to be 200% x rated residual current).

RCD TypeA.C. RMS Test Current (mA)

Maximum Tripping Time (mS)

Type I 10 40

Type II 30 300

Table 1 Maximum Tripping Times

RCD Test Results

RCD Inspection Log Book

30 © Clipsal Australia Pty Ltd

Typ

e o

f en

viro

nm

ent

and

/or

equ

ipm

ent

(a)

Inte

rval

bet

wee

n in

spec

tio

n a

nd

tes

ts

Co

rd

exte

nsi

on

set

s an

d E

PO

Ds

(h)

Cla

ss o

f eq

uip

men

tR

esid

ual

cu

rren

t d

evic

es (

RC

Ds)

Cla

ss I

(pro

tect

ivel

y ea

rth

ed)

(b)

Cla

ss II

(d

ou

ble

in

sula

ted

)(c

)

Pu

sh b

utt

on

tes

t by

use

rO

per

atin

g t

ime

RC

D t

este

r

Po

rtab

le(d

)F

ixed

(e)

Po

rtab

le(f

)F

ixed

(g)

1. F

acto

ries,

wor

ksho

ps: P

lace

s of

wor

k fo

r re

pair,

man

ufac

turin

g, a

ssem

bly,

mai

nten

ance

or

fabr

icat

ion.

6 m

onth

s12

mon

ths

Dai

ly, o

r be

fore

eve

ry

use

(whi

chev

er

is lo

nger

)

6 m

onth

s12

mon

ths

12 m

onth

s6

mon

ths

2. L

abor

ator

ies,

hea

lth c

are

and

educ

atio

nal

esta

blis

hmen

ts, t

ea r

oom

s an

d of

fice

kitc

hens

.12

mon

ths

12 m

onth

s

3 m

onth

s,or

be

fore

eve

ry

use

(whi

chev

er

is lo

nger

)

6 m

onth

s2

year

s2

year

s12

mon

ths

3. O

ffice

env

ironm

ent:

Whe

re th

e eq

uipm

ent o

r su

pply

flex

ible

cor

d is

sub

ject

to fl

exin

g in

nor

mal

us

e O

R is

ope

n to

abu

se O

R is

in a

hos

tile

envi

ronm

ent.

12 m

onth

s12

mon

ths

3 m

onth

s6

mon

ths

2 ye

ars

2 ye

ars

12 m

onth

s

4. O

ffice

env

ironm

ent:

Whe

re th

e eq

uipm

ent o

r su

pply

cor

d is

NO

T s

ubje

ct to

flex

ing

in n

orm

al

use

and

is N

OT

ope

n to

abu

se a

nd is

NO

T in

a

host

ile e

nviro

nmen

t.

5 ye

ars

5 ye

ars

3 m

onth

s6

mon

ths

2 ye

ars

2 ye

ars

5 ye

ars

Tab

le 2

Te

stin

g a

nd

insp

ecti

on

inte

rval

s fo

r el

ectr

ical

eq

uip

men

t

(CA

UT

ION

: Th

is p

age

mu

st b

e re

ad in

co

nju

nct

ion

wit

h t

he

AS

/NZ

S 3

760:

2003

Sta

nd

ard

as

a w

ho

le a

nd

par

ticu

larl

y C

lau

se 2

.1)

RCD Inspection Log Book

31© Clipsal Australia Pty Ltd

Typ

e o

f en

viro

nm

ent

and

/or

equ

ipm

ent

(a)

Inte

rval

bet

wee

n in

spec

tio

n a

nd

tes

ts

Co

rd

exte

nsi

on

set

s an

d E

PO

Ds

(h)

Cla

ss o

f eq

uip

men

tR

esid

ual

cu

rren

t d

evic

es (

RC

Ds)

Cla

ss I

(pro

tect

ivel

y ea

rth

ed)

(b)

Cla

ss II

(d

ou

ble

in

sula

ted

)(c

)

Pu

sh b

utt

on

tes

t by

use

rO

per

atin

g t

ime

RC

D t

este

r

Po

rtab

le(d

)F

ixed

(e)

Po

rtab

le(f

)F

ixed

(g)

5. H

ire e

quip

men

t (N

ote

3).

Insp

ect b

efor

e ea

ch h

ire. T

est

mon

thly

.

Insp

ect b

efor

e ea

ch h

ire. T

est

mon

thly

.

Prio

r to

eac

h hi

re. T

est

mon

thly

.N

/AP

rior

to e

ach

hire

. Tes

t m

onth

ly.

N/A

Insp

ect b

efor

e ea

ch h

ire. T

est

mon

thly

.

6. R

epai

red/

serv

iced

/sec

ond-

hand

equ

ipm

ent.

Afte

r re

pair

or s

ervi

ce, w

hich

cou

ld a

ffect

ele

ctric

al s

afet

y or

on

re-in

trod

uctio

n to

ser

vice

7. E

quip

men

t use

d fo

r co

mm

erci

al c

lean

ing.

6 m

onth

s12

mon

ths

3 m

onth

sN

/A2

year

sN

/A12

mon

ths

8. R

esid

entia

l typ

e ar

eas:

Res

iden

tial

inst

itutio

ns, h

otel

s, b

oard

ing

hous

es, h

ospi

tals

, ac

com

mod

atio

n ho

uses

, mot

els,

hot

els

and

the

like.

2 ye

ars

2 ye

ars

6 m

onth

s6

mon

ths

2 ye

ars

2 ye

ars

2 ye

ars

NO

TE

S:

1.

Mul

tiple

env

ironm

ents

may

exi

st in

any

loca

tion

e.g.

an

‘offi

ce’ c

lass

ifica

tion

and

a ‘la

bora

tory

’ cla

ssifi

catio

n m

ay e

xist

with

in a

‘fac

tory

’ est

ablis

hmen

t. 2.

R

egul

ator

y au

thor

ities

, oth

er S

tand

ards

, wor

kpla

ce s

afet

y re

quire

men

ts o

r m

anuf

actu

rers

’ ins

truc

tions

may

spe

cify

inte

rval

s ap

prop

riate

to p

artic

ular

indu

strie

s or

spe

cific

type

s of

equ

ipm

ent.

3.

RC

Ds

in tr

ansp

orta

ble

equi

pmen

t sha

ll be

reg

arde

d as

por

tabl

e R

CD

s.4.

T

he fo

llow

ing

stan

dard

s re

fer

only

to th

e in

spec

tion

and

test

ing

met

hod

of C

laus

e 2.

3 of

this

Sta

ndar

d, b

ut n

ot to

the

inte

rval

s of

test

ing

in T

able

2 a

bove

. Ref

er to

the

appr

opria

te s

tand

ard

for

spec

ific

test

inte

rval

s:•A

S/N

ZS

300

1 -

Ele

ctric

al in

stal

latio

ns -

mov

able

pre

mis

es (

incl

udin

g ca

rava

ns)

and

thei

r in

stal

latio

ns

•AS

/NZ

S 3

002

- E

lect

rical

inst

alla

tions

- s

how

s an

d ca

rniv

als

•AS

/NZ

S 3

003

- E

lect

rical

inst

alla

tions

- p

atie

nt tr

eatm

ent a

reas

of h

ospi

tals

and

med

ical

and

den

tal p

ract

ices

•A

S/N

ZS

300

4 -

Ele

ctric

al in

stal

latio

ns -

mar

inas

and

ple

asur

e cr

aft a

t low

vol

tage

•AS

/NZ

S 3

012

- E

lect

rical

inst

alla

tions

- c

onst

ruct

ion

and

dem

oliti

on s

ites

•A

S/N

ZS

4249

- E

lect

rical

inst

alla

tions

- fi

lm, v

ideo

and

tele

visi

on s

ites.

RCD Inspection Log Book

32 © Clipsal Australia Pty Ltd

Test for Operating Time of RCDs (Residual Current Devices)

(Normative)

D1 General The operating time of RCDs shall be checked to Clause 2.3.3.4 with maximum values to Table 1.

D2 Instrumentation An RCD tester to apply rated tripping current ±5% and measure time ±2.5%.

D3 Test Conditions A current, equal to the rated tripping current, shall be suddenly applied between active and protective Earth and the operating time measured.

Notes:

1. Tests are applied by the instrument test button (suddenly applied). In case of doubt, the number of test operations, up to five, may be required.

2. Some RCDs may have a different result (approximately 10mS) depending on the point on wave of the test current. In case of doubt, operating time at both 00 and 1800 should be tested.

3. Load leakage and stored energy can affect the result and increase the meter trip time indication. In case of doubt all load on the circuit should be disconnected.

4. A 240V test meter, used on 230V may give a low test current and corresponding longer times. Ensure the correct rating and tolerance of the test instrument.

5. Tests on three-phase units are carried out on one phase only. In case of doubt, as the vector of the test current and the load leakage current are important, the load should be disconnected.

6. The test from Active to Earth involves the complete Earth fault loop and the resistance of the Earth wire, or current flowing in the Earth wire may affect results. In case of doubt, a bench test may be required.

Appendix D

RCD Inspection Log Book

33© Clipsal Australia Pty Ltd

7. Portable RCDs which are permanently wired to terminals in equipment may be tested by push button only, observing the operating time, which should be without undue delay. In case of doubt, use an external timer circuit capable of detecting the test current start and finish, to measure disconnect time of not more than 150mS for a 30mA unit and 40mS for a 10mA unit. (The test button current is assumed to be 200% x rated residual current).

The following tests are not required by this Standard:

(a) Calibration sensitivity at slowly rising current

(b) Non trip threshold (50% rated sensitivity)

(e) d.c. pulse tests for class A. The test for operating time using a.c. for type A RCDs (a.c. and d.c. pulse half wave sensitive) is acceptable as d.c. calibration is linked to a.c. calibration and verified by type test. The test for operating time, ensures that both type AC (sine wave a.c.) and type A have retained their type test calibration.

RCD Inspection Log Book

34 © Clipsal Australia Pty Ltd

AS/NZS 3760:2003

Clause 2.3.2 Inspection

The following equipment checks shall be made by visual and physical inspection on all equipment:

• Checkforobviousdamageordefectsintheaccessories,connectors,plugs or extension outlet sockets.

Note:

(a) For low voltage portable equipment and cord extension sets fitted with AS/NZS 3112 type (flat pin) plugs and extension sockets, the use of clear backed or integrally moulded (non-rewireable) plugs, and cord extension sockets is recommended. Clear backed plugs and sockets facilitate the easy inspection of the effectiveness of the sheath grip.

(b) Check that flexible cords are effectively anchored to equipment, plugs and cord extension sockets.

Note:

• Thisinspection,includingflexingandstrainingatpointsofentryand clamping points, may be carried out in conjunction with the continuity test to Clause 2.3.3.1. This may detect broken strands or loose connections.

(c) Check for damage to flexible cords:

(i) The inner cores of flexible supply cords are not exposed or twisted.

(ii) The external sheaths are not cut, abraded, twisted, or damaged to such an extent that the insulation of the inner cores is visible.

(iii) Unprotected conductors or insulation tape are not in evidence.

RCD Inspection Log Book

35© Clipsal Australia Pty Ltd

Note:

• Running the supply cord through the hand will often detect internal damage.

(d) For portable outlet devices, check that the warning indicating the maximum load to be connected to the device is intact and legible.

(e) Check that any controls are in good working order i.e. they are secure, aligned and appropriately identified.

(f) Check that covers, guards and the like are secured in the manner intended by the manufacturer or supplier.

(g) Check that safety facilities and devices are in good working order.

(h) Check that ventilation inlets and exhausts are unobstructed.

F757/03 CLIPCOM 19571

Clipsal Australia Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.

© Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted.

Clipsal Australia Pty LtdA member of Schneider Electric

Contact us: clipsal.com/feedback

National Customer Care Enquiries:

Tel 1300 2025 25 Fax 1300 2025 56

clipsal.com