rc ii_ch_03-2_flat slab.pdf

Upload: eph

Post on 14-Jan-2016

11 views

Category:

Documents


0 download

TRANSCRIPT

  • 1

    3.2 Flat slabs

    3.2.1 Introduction

    Slabs which are not supported by beams or walls along the edges but are supported directly

    by columns are known as flat slabs (Fig. 3.2.1). The required slab depth for such a system is

    generally less than for a one-way spanning slab system but greater than for a two-way

    spanning slab system. However, the use of flat slabs results in a reduced depth of structure

    overall as beams, when they are present, govern the structural depth. Another great advantage

    of this system is that it only requires simple shuttering there are no beams for which

    formwork must be prepared. One disadvantage of flat slab construction is that the

    arrangement of reinforcement can be very complex, particularly adjacent to columns where

    punching shear reinforcement is often required if the slab depth is kept to a minimum.

    Flat slabs are often provided with drops or enlarged column heads, as illustrated in Fig.

    3.2.2, to increase the shear strength of the slab around the column supports. However, this

    substantially increases the complexity of the shuttering, countering one of the principal

    advantages of the system.

    Figure 3.2.1 Flat slab construction

  • 2

    3.2.2 Methods of Analysis

    A flat slab including supporting columns or walls may be analyzed using the equivalent

    frame method or, where applicable, the simplified method. The provision in the methods are

    for the design of flat slabs supported by a generally rectangular arrangement of columns and

    where the ratio of the longer to the shorter spans does not exceed 2. A flat slab is subdivided

    into column and middle strips (Fig. 3.2.3). Column strip is a design strip with a width on each

    side of a column center-line equal to 0.25Lx or if drops with dimension not less than Lx/3 are

    used, a width equal to the drop dimension. Middle strip is a design strip bounded by two

    column strips.

    For both methods of analysis, the negative moments greater than those at a distance hc/2 from

    the center-line of the column may be ignored provided the moment Mo obtained as the sum of

    the maximum positive design moment and the average of the negative design moments in any

    one span of the slab for the whole panel width is such that:

    Figure 3.2.2 Flat slab construction details: (a) no column head; (b) flared column head;

    (c) slab with drop panel; (d) flared column head and drop panel.

  • 3

    2

    12

    03

    2

    8

    cdd

    hL

    LqgM

    Where L1 = panel length parallel to span, measured from centers of columns.

    L2 = panel width, measured from centers of columns

    hc = effective diameter of a column or column head.

    When the above condition is not satisfied, the negative design moments shall be increased.

    The effective diameter of a column or column head hc is the diameter of a circle

    whose area equals the cross-sectional area of the column or, if column heads are used,

    the area of the column head based on the effective dimensions as defined below. In no

    case shall hc be taken as greater than one-quarter of the shortest span framing into the

    column.

    Figure 3.2.3 Division of Panels in Flat Slabs

  • 4

    The effective dimensions of a column head for use in calculation of hc are limited

    according to the depth of the head. In any direction, the effective dimension of a head

    Lh shall be taken as

    The lesser of the actual dimension Lh o , or Lh,max, where Lh,max is given by:

    Lh,max = Lc + 2dh

    For a flared head, the actual dimension Lho is that measured to the center of the

    reinforcing steel (see Fig. 3.2.4).

    A drop may only be considered to influence the distribution of moments within the

    slab where the smaller dimension of the drop is at least one third of the smaller

    dimension of the surrounding panels. Smaller drops may, however, still be taken into

    account when assessing the resistance to punching shear.

    Equivalent Frame Method

    Structure may be divided longitudinally and transversely into frames consisting of

    columns and strips of slab

    The width of slab used to define the effective stiffness of the slab will depend upon

    the aspect ratio of the panels and the type of loading, but the following provisions

    may be applied in the absence of more accurate methods:

    In the case of vertical loading, the full width of the panel, and

    Figure 3.2.4 Types of Column Head

  • 5

    For lateral loading, half the width of the panel may be used to calculate the

    stiffness of the slab.

    The moment of inertia of any section of slab or column used in calculating the relative

    stiffness of members may be assumed to be that of the cross section of the concrete

    alone.

    Moments and forces within a system of flat slab panels may be obtained from analysis

    of the structure under the single load case of maximum design load on all spans or

    panels simultaneously, provided:

    The ratio of the characteristic imposed load to the characteristic dead load

    does not exceed 1.25.

    The characteristic imposed load does not exceed 5.0 kN/m2 excluding

    partitions.

    Where it is not appropriate to analyze for the single load case of maximum design

    load on all spans, it will be sufficient to consider the following arrangements of

    vertical loads:

    All spans loaded with the maximum design ultimate load, and

    Alternative spans with the maximum design ultimate load, and all other spans

    loaded with the minimum design ultimate load (1.0Gk)

    Each frame may be analyzed in its entirety by any elastic method. Alternatively, for

    vertical loads only, each strip of floor and roof may be analyzed as a separate frame

    with the columns above and below fixed in position and direction at their extremities,

    In either case, the analysis shall be carried out for the appropriate design ultimate

    loads on each span calculated for a strip of slab of width equal to the distance between

    center lines of the panels on each side of the columns.

    Simplified Method

    Moments and shear forces in non-sway flat slab structures may be determined using

    Table 3.2.1, subject to the conditions described below.

    The following limitations shall be observed when using the simplified method:

    Design is based on the single load case of all spans loaded with the maximum

    design ultimate load.

    There are at least three rows of panels of approximately equal span in the direction

    being considered.

    Successive span length in each direction shall not differ by more than one-third of

    the longer span.

  • 6

    Maximum offsets of columns from either axis between center lines of successive

    columns shall not exceed 10% of the span (in the direction of the offset).

    Table 3.2.1 Bending Moment and Shear Force Coefficients for Flat Slabs of Three or

    More Equal Spans

    Outer support

    Near

    Center of

    first span

    First

    Interior

    support

    Center of

    interior

    span

    Interior

    support

    Column

    Wall

    Moment

    Shear

    Total column

    moments

    -0.040FL

    0.45F

    0.040FL

    -0.020FL

    0.40F

    -

    0.083FL

    -

    -

    -0.063FL

    0.60F

    0.022FL

    0.071FL

    -

    -

    -0.055FL

    0.50F

    0.022FL

    NOTE 1. F is the total design ultimate load on the strip of slab between adjacent columns considered.

    2. L is the effective span = L1 -2hc/3.

    3. The limitations in section 3.2.2 need not be checked.

    4. The moments shall not be redistributed.

    Figure 3.2.5 Building idealization for equivalent frame analysis

  • 7

    Division of Moments between Column and Middle Strips

    The design moments obtained from analysis of the continuous frames using the

    Equivalent Frame method or from simplified method shall be divided between the

    column and middle strips in the proportions given in Table 3.2.2.

    Table 3.2.2 Distribution of Design Moments in Panels of Flat Slabs

    Apportionment between column and middle strip expressed as

    percentages of the total negative or positive design moment

    Column strip (%) Middle strip (%)

    Negative

    Positive

    75

    55

    25

    45

    NOTE: For the case where the width of the column strip is taken as equal to that of the drop,

    and the middle strip is thereby increased in width, the design moments to be resisted by the

    middle strip shall be increased in proportion to its increased width. The design moments to be

    resisted by the column strip may be decreased by an amount such that the total positive and

    the total negative design moments resisted by the column strip and middle strip together are

    unchanged.

    3.2.3 Design Considerations

    General

    Details of reinforcement in flat slabs shall be as follows:

    The reinforcement in flat slabs shall have minimum bend point locations and

    extensions for reinforcement as prescribed in Fig. 3.2.6.

    Where adjacent spans are unequal, extension of negative reinforcement beyond the

    face of support as prescribed in Fig. 3.2.6 shall be based on requirements of longer

    span.

    Bent bars may be used only when depth-to-span ratio permits use of bends 450 or

    less.

    For flat slabs in frames not braced against side sway and for flat slabs resisting lateral

    loads, lengths of reinforcement shall be determined by analysis but shall not be less than

    those prescribed in Fig. 3.2.6.

  • 8

    Figure 3.2.6 Minimum Bend Point Location and Extension for Reinforcement in Flat

    Slabs

  • 9

    Internal panels

    The column and middle strips shall be designed to withstand the design moments

    obtained from section 3.2.2.

    Two-thirds of the amount of reinforcement required to resist the negative design moment

    in the column strip shall be placed in a width equal to half that of the column strip and

    central with the column. This concentration of reinforcement over the column will

    increase the capacity of the slab for transfer of moment to the column by flexure (see

    Section 3.2.4)

    Edge panels

    The design moments shall be apportioned and designed exactly as for an internal panel,

    using the same column and middle strips as for an internal panel.

    3.2.4 Moment Transfer between Slab and Column

    (a) When gravity load, wind, earthquake, or other lateral forces cause transfer of moment

    between slab and column, a fraction of the unbalanced moment shall be transferred by

    flexure. Fraction of unbalanced moment not transferred by flexure shall be transferred

    by eccentricity of shear in accordance with Section 3.2.4.

    (b) A fraction of the unbalanced moment given by

    shall be considered transferred by flexure over an effective slab width between lines

    that are one and one half slab or drop panel thickness (1.5h) outside opposite faces of

    the column or capital.

    (c) Concentration of reinforcement over the column by closer spacing as specified in

    Section 3.2.2, or additional reinforcement must be used to resist the unbalanced

    moment on the effective slab width defined in (b).

    (d) The design for transfer of load from slab to supporting columns or walls through shear

    and torsion shall be in accordance with Section 3.2.4.

    (e) As an alternative to (b) above, the slab may be designed for the minimum bending

    moments per unit width, msdx and msdy in the x and y direction, respectively, given by

    Equation below (see Fig. 3.2.7).

    211

    1

    bb

  • 10

    Msdx (or msdy) nVsd

    Where Vsd is the shear force developed along the critical section

    n is the moment coefficient given in Table 3.2.3.

    (f) In checking the corresponding resisting moments, only those reinforcing bars shall be

    taken into account, which are appropriately anchored beyond the critical area (Fig.

    3.2.8)

    (g) Where analysis of the structure indicates a design column moment larger than the

    moment Mt,max which can be transferred by flexure and shear combined (in accordance

    with (b) and (d) above), the design edge moment in the slab shall be reduced to a value

    not greater than Mt,max and the positive design moments in the span adjusted

    accordingly. The normal limitations on redistributions and neutral axis depth may be

    disregarded in this case.

    (h) Moments in excess of Mt,max may only be trsnsferred to a column if an edge beam or

    strip of slab along the free edge is reinforced to carry the extra moment into the column

    by torsion.

    (i) In the absence of an edge beam, an appropriate breadth of slab may be assessed by using

    the principles illustrated in Fig. 3.2.9, for transfer of moment between the slab and an

    edge or corner column.

    Table 3.2.3 Moment Coefficient nfor Equation (A.10)

    Position of

    column

    n for msdy

    Effective

    width

    n for msdy

    Effective

    width

    top

    bottom

    top bottom

    Internal column

    Edge columns

    Edge of slab

    Parallel, to x-

    axis

    Edge columns

    Edge of slab

    Parallel to y-axis

    Corner column

    -0.125

    -0.25

    -0.125

    -0.5

    0

    0

    0.125

    0.5

    0.3Ly

    0.15Ly

    (per m)

    (per m)

    -0.125

    -0.125

    -0.25

    -0.5

    0

    0.125

    0

    0.5

    0.3Lx

    (per m)

    0.15.Lx

    (per m)

  • 11

    Figure 3.2.7 Bending Moments mSdx and mSdy in Slab-Column Joints subjected to

    Eccentric Loading, and Effective Width for resisting these Moments.

    Figure 3.2.8 Detailing Reinforcement over Edge and Corner Columns

  • 12

    3.2.5 Design of slabs for punching shear

    The punching shear failure mechanism illustrated in Fig. 3.2.10 can occur in any two-way

    spanning members which are supported directly by columns or which are acted on by heavy

    concentrated loads. The cross-sectional shape of the supporting column or the concentrated

    load, known as the loaded area, determines the shape of the failure surface in the concrete

    slab. In particular, circular loaded areas cause conical wedges to form and rectangular loaded

    areas cause pyramidal wedges to form. For design purposes, the inclined surfaces are

    represented by vertical ones. It is assumed that these vertical surfaces occur at a constant

    distance from the edges of the loaded area as illustrated in Fig. 3.2.11. The corresponding

    perimeter, illustrated in both figures, is known as the critical perimeter.

    Figure 3.2.9 Definition of Breadth of Effective Moment Transfer Strip be for

    Typical Cases

  • 13

    Figure 3.2.10 Punching shear failure at column

    support

    Figure 3.2.11 Critical perimeters for punching shear

  • 14

    Checking for punching shear in slabs with constant depth

    As for regular shear, the average applied shear stress in a member with punching shear is

    given by equation:

    = V/bwd

    However , in the case of members with punching shear, the breadth of the section in shear

    is equal to the length of the critical perimeter. Further , with punching shear, there are two

    effective depths, one for reinforcement running parallel to the X-axis and one for

    reinforcement running parallel to the Y-axis (the layers of reinforcement will, of

    necessity, be at different depths as one must rest on the other). Thus, for punching shear,

    the average shear stress becomes:

    = V/udav

    where u = length of the critical perimeter

    dav = average of the two effective depths.

    The shear strength, c, for members subjected to punching, is calculated differently

    c = 0.25fctdk1k2udav

    Where: 0.25011 ek

    0.16.12 dk - scale effect parameter (d in meters)

    2yxav ddd

    015.021 eyexe - effective longitudinal reinforcement ratio.

    ex and ex = geometric ratios longitudinal reinforcement parallel to x and y,

    respectively

    When the punching shear force due to applied loads is eccentric to the loaded area or the

    force is combined with a moment as would happen in an edge or corner column (see Fig.

    3.2.12), the adverse effect of the applied load is significantly increased. This effect is

    allowed for by the multiplication of the applied force, Vsd , by a factor . When no

    eccentricity of loading is possible, =1. In other cases, can be taken from equation

    below or Fig. 3.2.12.

    Veq = Vsd

  • 15

    Where: Zeud 1

    e = eccentricity of the load or reaction with respect to the centroid of the

    critical section, always positive.

    Z = section modulus of the critical section, corresponding to the direction of

    the eccentricity.

    1211 bb - fraction of moment which is considered transferred by eccentricity of the shear about the centroid of the critical section.

    b1 and b2 = sides of the rectangle of outline u, b1 being parallel to the direction

    of the eccentricity e.

    Figure 3.2.12 Factor to allow for eccentricity of loading