Page 1: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

1

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009

Page 2: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

2

Unit Data - RCA 051Pe

rfor

man

ce

Dat

a

Net Cooling

Total Capacity (Btu/h) 46,500

Electric Power (W) 3,550

Energy Efficiency Ratio (EER) 13.1

Integrated Energy Efficiency Ratio (IEER) 14.4

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 3.5 - Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 230/1/60 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 21.8 13.7 6.2 4.8

Locked Rotor Amps (LRA) 117 83 41 33

Condenser Fan Motor(s)

Qty - Horsepower (HP) 1 - 1/2

FLA (ea) 6.2 5.4 2.7 1.3

Type PSC

UnitUnit Minimum Circuit Ampacity 33.5 22.5 10.5 7.3

Max. Time Delay Fuse or HACR Breaker 50 35 15 15

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 4,000

Diameter (in)-Pitch (deg) 24 - 36

Condenser Coil(s)

Quantity 2

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 15.4

Rows - Fins per Inch 4 - 12

Refrigerant Connection(s)

Suction Line (in OD) 3/4 (Qty 1)

Liquid Line (in OD) 1/2 (Qty 1)

Optional Hot Gas Bypass (in OD) 3/8 (Qty 1)

Optional Hot Gas Reheat (in OD) 3/8 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 24

WeightsUnit Weight (lbs) 565

Shipping Weight (lbs) 615

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Cool

ing

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0Total Capacity (Btu/h) 39,000 37,400 36,000

Electric Power (W) 3,370 3,560 3,765

40.0Total Capacity (Btu/h) 42,500 41,000 39,500

Electric Power (W) 3,380 3,575 3,780

45.0Total Capacity (Btu/h) 46,500 44,500 43,000

Electric Power (W) 3,400 3,590 3,800

50.0Total Capacity (Btu/h) 50,500 48,500 47,000

Electric Power (W) 3,420 3,615 3,815

55.0Total Capacity (Btu/h) 54,500 52,500 50,500

Electric Power (W) 3,440 3,635 3,840

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 3: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

3

Perf

orm

ance

D

ata

Net Cooling

Total Capacity (Btu/h) 55,600

Electric Power (W) 4,244

Energy Efficiency Ratio (EER) 13.1

Integrated Energy Efficiency Ratio (IEER) 14.2

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 4.5 - Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 230/1/60 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 26.4 16.0 7.8 7.6

Locked Rotor Amps (LRA) 134 110 52 54

Condenser Fan Motor(s)

Qty - Horsepower (HP) 1 - 1/2

FLA (ea) 6.2 5.4 2.7 1.3

Type PSC

UnitUnit Minimum Circuit Ampacity 39.2 25.3 12.3 8.4

Max. Time Delay Fuse or HACR Breaker 60 40 20 15

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 4,000

Diameter (in)-Pitch (deg) 24 - 36

Condenser Coil(s)

Quantity 2

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 15.4

Rows - Fins per Inch 4 - 12

Refrigerant Connection(s)

Suction Line (in OD) 7/8 (Qty 1)

Liquid Line (in OD) 1/2 (Qty 1)

Optional Hot Gas Bypass (in OD) 3/8 (Qty 1)

Optional Hot Gas Reheat (in OD) 3/8 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 24

WeightsUnit Weight (lbs) 590

Shipping Weight (lbs) 640

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Unit Data - RCA 061 Co

olin

g

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0Total Capacity (Btu/h) 45,000 43,000 42,000

Electric Power (W) 4,250 4,485 4,775

40.0Total Capacity (Btu/h) 53,500 47,000 46,000

Electric Power (W) 4,355 4,530 4,785

45.0Total Capacity (Btu/h) 55,000 51,000 50,000

Electric Power (W) 4,380 4,615 4,865

50.0Total Capacity (Btu/h) 57,000 56,000 54,000

Electric Power (W) 4,435 4,675 4,930

55.0Total Capacity (Btu/h) 62,000 60,000 58,000

Electric Power (W) 4,530 4,770 5,035

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 4: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

4

Perf

orm

ance

D

ata

Net Cooling

Total Capacity (Btu/h) 74,500

Electric Power (W) 6,422

Energy Efficiency Ratio (EER) 11.6

Integrated Energy Efficiency Ratio (IEER) 12.7

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 6.3 - Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 23.2 11.2 7.7

Locked Rotor Amps (LRA) 164 75 54

Condenser Fan Motor(s)

Qty - Horsepower (HP) 1 - 1/2

FLA (ea) 5.4 2.7 1.3

Type PSC

UnitUnit Minimum Circuit Ampacity 34.4 16.7 11.2

Max. Time Delay Fuse or HACR Breaker 50 25 15

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 4,000

Diameter (in)-Pitch (deg) 24 - 36

Condenser Coil(s)

Quantity 2

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 15.4

Rows - Fins per Inch 4 - 12

Refrigerant Connection(s)

Suction Line (in OD) 7/8 (Qty 1)

Liquid Line (in OD) 1/2 (Qty 1)

Optional Hot Gas Bypass (in OD) 3/8 (Qty 1)

Optional Hot Gas Reheat (in OD) 1/2 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 25

WeightsUnit Weight (lbs) 610

Shipping Weight (lbs) 660

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Unit Data - RCA 071Co

olin

g

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0Total Capacity (Btu/h) 60,200 58,000 56,000

Electric Power (W) 6,285 6,585 6,905

40.0Total Capacity (Btu/h) 66,000 63,000 61,000

Electric Power (W) 6,415 6,720 7,045

45.0Total Capacity (Btu/h) 71,000 69,000 66,000

Electric Power (W) 6,600 6,860 7,245

50.0Total Capacity (Btu/h) 77,000 74,000 71,000

Electric Power (W) 6,695 7,005 7,330

55.0Total Capacity (Btu/h) 82,000 80,000 77,000

Electric Power (W) 6,840 7,150 7,480

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 5: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

5

Perf

orm

ance

D

ata

Net Cooling

Total Capacity (Btu/h) 107,500

Electric Power (W) 9,430

Energy Efficiency Ratio (EER) 11.4

Integrated Energy Efficiency Ratio (IEER) 12.8

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 9.0 - Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 30.1 16.7 12.2

Locked Rotor Amps (LRA) 225 114 80

Condenser Fan Motor(s)

Qty - Horsepower (HP) 1 - 1

FLA (ea) 5.4 2.7 2.0

Type PSC

UnitUnit Minimum Circuit Ampacity 41.6 23.1 19.3

Max. Time Delay Fuse or HACR Breaker 70 35 30

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 6,200

Diameter (in)-Pitch (deg) 26 - 26

Condenser Coil(s)

Quantity 3

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 23.1

Rows - Fins per Inch 4 - 12

Refrigerant Connection(s)

Suction Line (in OD) 11/8 (Qty 1)

Liquid Line (in OD) 5/8 (Qty 1)

Optional Hot Gas Bypass (in OD) 1/2 (Qty 1)

Optional Hot Gas Reheat (in OD) 5/8 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 30

WeightsUnit Weight (lbs) 825

Shipping Weight (lbs) 900

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Unit Data - RCA 101Co

olin

g

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0TTotal Capacity (Btu/h) 89,000 86,000 83,000

Electric Power (W) 8,910 9,435 9,840

40.0Total Capacity (Btu/h) 97,000 94,000 90,000

Electric Power (W) 9,130 9,515 10,075

45.0Total Capacity (Btu/h) 105,000 101,000 98,000

Electric Power (W) 9,300 9,750 10,225

50.0Total Capacity (Btu/h) 113,000 109,000 106,000

Electric Power (W) 9,465 9,935 10,395

55.0Total Capacity (Btu/h) 122,000 118,000 113,000

Electric Power (W) 9,660 10,110 10,680

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 6: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

6

Perf

orm

ance

D

ata

Net Cooling

Total Capacity (Btu/h) 137,100

Electric Power (W) 12,578

Energy Efficiency Ratio (EER) 10.9

Integrated Energy Efficiency Ratio (IEER) 12.2

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 12.0 - Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 48.1 18.6 15.1

Locked Rotor Amps (LRA) 245 125 100

Condenser Fan Motor(s)

Qty - Horsepower (HP) 1 - 1

FLA (ea) 5.4 2.7 2.0

Type PSC

UnitUnit Minimum Circuit Ampacity 64.0 25.4 22.4

Max. Time Delay Fuse or HACR Breaker 110 40 35

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 6,200

Diameter (in)-Pitch (deg) 26 - 26

Condenser Coil(s)

Quantity 3

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 23.1

Rows - Fins per Inch 4 - 12

Refrigerant Connection(s)

Suction Line (in OD) 13/8 (Qty 1)

Liquid Line (in OD) 5/8 (Qty 1)

Optional Hot Gas Bypass (in OD) 1/2 (Qty 1)

Optional Hot Gas Reheat (in OD) 5/8 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 35

WeightsUnit Weight (lbs) 900

Shipping Weight (lbs) 975

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Unit Data - RCA 141Co

olin

g

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0Total Capacity (Btu/h) 113,000 110,000 106,000

Electric Power (W) 12,000 12,470 13,085

40.0Total Capacity (Btu/h) 124,000 119,000 115,000

Electric Power (W) 12,150 12,845 13,340

45.0Total Capacity (Btu/h) 133,000 129,000 124,000

Electric Power (W) 12,535 13,005 13,615

50.0Total Capacity (Btu/h) 143,000 139,000 134,000

Electric Power (W) 12,710 13,295 13,905

55.0Total Capacity (Btu/h) 153,000 148,000 144,000

Electric Power (W) 13,070 13,710 14,210

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 7: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

7

Unit Data - RCA 171Pe

rfor

man

ce

Dat

a

Net Cooling

Total Capacity (Btu/h) 165,900

Electric Power (W) 13,598

Energy Efficiency Ratio (EER) 12.2

Integrated Energy Efficiency Ratio (IEER) 13.6

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 13.5 - Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 51.3 23.1 19.9

Locked Rotor Amps (LRA) 300 150 109

Condenser Fan Motor(s)

Qty - Horsepower (HP) 2 - 1

FLA (ea) 3.4 / 5.4 1.7 / 2.7 2.0/2.0

Type PSC

UnitUnit Minimum Circuit Ampacity 74.8 33.4 28.9

Max. Time Delay Fuse or HACR Breaker 125 50 45

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 12,400

Diameter (in)-Pitch (deg) 26 - 32

Condenser Coil(s)

Quantity 4

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 30.8

Rows - Fins per Inch 4 - 12

Refrigerant Connection(s)

Suction Line (in OD) 13/8 (Qty 1)

Liquid Line (in OD) 7/8 (Qty 1)

Optional Hot Gas Bypass (in OD) 5/8 (Qty 1)

Optional Hot Gas Reheat (in OD) 5/8 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 50

WeightsUnit Weight (lbs) 1,250

Shipping Weight (lbs) 1,345

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Cool

ing

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0Total Capacity (Btu/h) 144,000 138,000 133,000

Electric Power (W) 12,265 12,865 13,540

40.0Total Capacity (Btu/h) 157,000 151,000 146,000

Electric Power (W) 12,400 13,015 13,670

45.0Total Capacity (Btu/h) 170,000 164,000 158,000

Electric Power (W) 12,560 13,170 13,820

50.0Total Capacity (Btu/h) 183,000 177,000 171,000

Electric Power (W) 12,775 13,390 14,015

55.0Total Capacity (Btu/h) 198,000 191,000 185,000

Electric Power (W) 12,980 13,560 14,180

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 8: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

8

Unit Data - RCA 201Pe

rfor

man

ce

Dat

a

Net Cooling

Total Capacity (Btu/h) 192,000

Electric Power (W) 16,271

Energy Efficiency Ratio (EER) 11.8

Integrated Energy Efficiency Ratio (IEER) 13.2

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 15.0 - Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 55.8 26.9 23.7

Locked Rotor Amps (LRA) 340 173 132

Condenser Fan Motor(s)

Qty - Horsepower (HP) 2 - 1

FLA (ea) 3.4 / 5.4 1.7 / 2.7 2.0/2.0

Type PSC

UnitUnit Minimum Circuit Ampacity 78.8 40.0 57.6

Max. Time Delay Fuse or HACR Breaker 125 60 80

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 12,400

Diameter (in)-Pitch (deg) 26 - 32

Condenser Coil(s)

Quantity 4

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 30.8

Rows - Fins per Inch 4 - 12

Refrigerant Connection(s)

Suction Line (in OD) 13/8 (Qty 1)

Liquid Line (in OD) 7/8 (Qty 1)

Optional Hot Gas Bypass (in OD) 5/8 (Qty 1)

Optional Hot Gas Reheat (in OD) 3/4 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 58

WeightsUnit Weight (lbs) 1,300

Shipping Weight (lbs) 1,400

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Cool

ing

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0Total Capacity (Btu/h) 167,000 161,000 155,000

Electric Power (W) 14,500 15,230 16,020

40.0Total Capacity (Btu/h) 182,000 176,000 170,000

Electric Power (W) 14,740 15,415 16,175

45.0Total Capacity (Btu/h) 197,000 191,000 185,000

Electric Power (W) 14,955 15,665 16,355

50.0Total Capacity (Btu/h) 213,000 207,000 199,000

Electric Power (W) 15,170 15,865 16,635

55.0Total Capacity (Btu/h) 230,000 223,000 215,000

Electric Power (W) 15,390 16,100 16,850

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 9: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

9

Unit Data - RCA 271Pe

rfor

man

ce

Dat

a

Net Cooling

Total Capacity (Btu/h) 241,300

Electric Power (W) 22,343

Energy Efficiency Ratio (EER) 10.8

Integrated Energy Efficiency Ratio (IEER) 12.4

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 21.0 - Tandem Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 33.3 17.9 12.8

Locked Rotor Amps (LRA) 239 125 80

Condenser Fan Motor(s)

Qty - Horsepower (HP) 2 - 1

FLA (ea) 3.4 / 5.4 1.7 / 2.7 2.0/2.0

Type PSC

UnitUnit Minimum Circuit Ampacity 85.7 45.7 32.8

Max. Time Delay Fuse or HACR Breaker 110 60 45

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 12,400

Diameter (in)-Pitch (deg) 26 - 32

Condenser Coil(s)

Quantity 4

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 30.8

Rows - Fins per Inch 4 - 12

Refrigerant Connection(s)

Suction Line (in OD) 15/8 (Qty 1)

Liquid Line (in OD) 7/8 (Qty 1)

Optional Hot Gas Bypass (in OD) 5/8 (Qty 1)

Optional Hot Gas Reheat (in OD) 7/8 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 58

WeightsUnit Weight (lbs) 1,400

Shipping Weight (lbs) 1,500

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Cool

ing

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0Total Capacity (Btu/h) 213,000 205,000 197,000

Electric Power (W) 19,315 20,310 21,360

40.0Total Capacity (Btu/h) 232,000 224,000 216,000

Electric Power (W) 19,590 20,570 21,620

45.0Total Capacity (Btu/h) 252,000 243,000 236,000

Electric Power (W) 20,020 21,000 21,895

50.0Total Capacity (Btu/h) 273,000 264,000 254,000

Electric Power (W) 20,360 21,330 22,365

55.0Total Capacity (Btu/h) 294,000 284,000 275,000

Electric Power (W) 20,720 21,700 22,730

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 10: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

10

Unit Data - RCA 361Pe

rfor

man

ce

Dat

a

Net Cooling

Total Capacity (Btu/h) 288,600

Electric Power (W) 24,879

Energy Efficiency Ratio (EER) 11.6

Integrated Energy Efficiency Ratio (IEER) 12.8

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 24.0 - Tandem Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 48.1 18.6 15.1

Locked Rotor Amps (LRA) 245 125 100

Condenser Fan Motor(s)

Qty - Horsepower (HP) 4 - 1

FLA (ea) 3.4 / 3.4 / 5.4 / 5.4 1.7 / 1.7 / 2.7 / 2.7 2.0 / 2.0 / 2.0 / 2.0

Type PSC

UnitUnit Minimum Circuit Ampacity 125.6 51.6 41.1

Max. Time Delay Fuse or HACR Breaker 150 70 50.0

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 28,000

Diameter (in)-Pitch (deg) 26 - 32

Condenser Coil(s)

Quantity 4

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 70.0

Rows - Fins per Inch 2 - 14

Refrigerant Connection(s)

Suction Line (in OD) 15/8 (Qty 1)

Liquid Line (in OD) 11/8 (Qty 1)

Optional Hot Gas Bypass (in OD) 7/8 (Qty 1)

Optional Hot Gas Reheat (in OD) 7/8 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 65

WeightsUnit Weight (lbs) 1,700

Shipping Weight (lbs) 1,820

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Cool

ing

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0Total Capacity (Btu/h) 240,000 231,000 221,000

Electric Power (W) 23,635 24,700 26,050

40.0Total Capacity (Btu/h) 260,000 251,000 243,000

Electric Power (W) 24,090 25,140 26,135

45.0Total Capacity (Btu/h) 283,000 274,000 264,000

Electric Power (W) 24,410 25,485 26,620

50.0Total Capacity (Btu/h) 306,000 296,000 285,000

Electric Power (W) 24,890 26,010 27,190

55.0Total Capacity (Btu/h) 332,000 320,000 309,000

Electric Power (W) 25,085 26,360 27,570

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 11: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

11

Unit Data - RCA 421

Perf

orm

ance

D

ata

Net Cooling

Total Capacity (Btu/h) 369,700

Electric Power (W) 33,609

Energy Efficiency Ratio (EER) 11.0

Integrated Energy Efficiency Ratio (IEER) 12.2

Elec

tric

al D

ata

Compressor(s)

Qty-Nominal Tons-Type 1 - 31.5 - Tandem Scroll

Capacity Reduction 0/50/100 (HGBP) or 0/10-100 (Digital)

Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60

Run Load Amps (RLA) 55.8 26.9 23.8

Locked Rotor Amps (LRA) 340 173 132

Condenser Fan Motor(s)

Qty - Horsepower (HP) 4 - 1

FLA (ea) 3.4 / 3.4 / 5.4 / 5.4 1.7 / 1.7 / 2.7 / 2.7 2.0 / 2.0 / 2.0 / 2.0

Type PSC

UnitUnit Minimum Circuit Ampacity 142.4 70.5 61.4

Max. Time Delay Fuse or HACR Breaker 175 90 85

Mec

hani

cal D

ata

Condenser Fan(s)Airflow (CFM) 28,000

Diameter (in)-Pitch (deg) 26 - 32

Condenser Coil(s)

Quantity 4

Tube Material - Fin Material Copper - Aluminum

Face Area (sq. ft) 70.0

Rows - Fins per Inch 2 - 14

Refrigerant Connection(s)

Suction Line (in OD) 21/8 (Qty 1)

Liquid Line (in OD) 11/8 (Qty 1)

Optional Hot Gas Bypass (in OD) 7/8 (Qty 1)

Optional Hot Gas Reheat (in OD) 7/8 (Qty 1)

Cabinet

Sheet Metal G90 Galvanized

Finish Polyester Coating

Top Pan Thickness (ga) 16

Sides and Panels Thickness (ga) 18

Bottom Pan Thickness (ga) 16

Refrigerant - R410A Charge based on 25' line set (lbs per circuit) 75

WeightsUnit Weight (lbs) 1,770

Shipping Weight (lbs) 1,900

NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see “Reference Information” tables on pages 18 - 19.

Cool

ing

Saturated Suction Temperature (°F)

Ambient Temperature (°F)

95.0 100.0 105.0

35.0Total Capacity (Btu/h) 306,000 294,000 285,000

Electric Power (W) 31,685 33,335 34,495

40.0Total Capacity (Btu/h) 334,000 322,000 309,000

Electric Power (W) 32,350 33,705 35,465

45.0Total Capacity (Btu/h) 359,000 350,000 338,000

Electric Power (W) 33,355 34,440 35,885

50.0Total Capacity (Btu/h) 391,000 375,000 365,000

Electric Power (W) 33,900 35,550 36,695

55.0Total Capacity (Btu/h) 421,000 407,000 391,000

Electric Power (W) 34,815 36,165 37,925

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009.

Page 12: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

12

NOTES: 1. Condensing unit disconnect is not provided with condensing unit as standard. Disconnect may be obtained from factory as optional equipment or provided by others. 2. Air handler, air handler disconnect, interconnecting control wiring, all refrigerant line piping and sleeve/flashing materials are by others. 3. Suction, hot gas bypass, and hot gas reheat lines should be insulated with 5/8” minimum thickness closed cell foam insulation. Liquid line exposed to high ambient temperatures should be insulated 5/8” minimum thickness closed cell foam insulation.

Typical Split System Installation

Typical Wiring Diagram

L1

L2

L3

Condensing UnitControl Panel

G

R

C

Condensing Unit

Disconnect

Y

24VAC, Switched

Compressor

Supply Fan

24VAC, Common, Unswitched

NOTES: 1. All electrical wiring and connections, including electrical grounding must comply with: a. United States: Refer to NFPA 70- latest revision, National Electrical Code, and local ordinances. b. Canada: Refer to CSA C22.1, Part 1- latest revision, Canadian Electrical Code and local ordinances. 2. Class 1 circuit 3. Condensing unit disconnect is not provided with condensing unit as standard. Disconnect may be obtained from factory as optional equipment or provided by others. 4. Terminal Y2 is only used on dual-circuit units.

Outside Air or Return Air

Liquid Line

Suction Line

Sleeve And Flashing

Disconnect

Interconnecting Control Wiring

Condensing Unit

Optional Hot Gas ReheatOptional Hot Gas Bypass

Air HandlerSupply Air

Disconnect

Trap And Drain Connection

Page 13: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

13

Typical Installation with Unit on Bottom

NOTES: 1. To prevent oil migration, lines should slope downwards towards the condensing unit and should slope downward away from the air handler. 2. Vertical risers greater than 4' in height should have a “P” trap installed at the base of the air handler. 3. Vertical risers greater than 20' in height require an extra “P” trap for every 20' of riser height in addition to the “P” trap installed at the base of the air handler. The trap is inverted at the top of the vertical rise.

NOTES: 1. To prevent oil migration, lines should slope downwards towards the condensing unit and should slope downward away from the air handler. 2. Vertical risers greater than 4' in height should have a “P” trap installed at the base of the air handler. 3. Vertical risers greater than 20' in height require an extra “P” trap for every 20' of riser height in addition to the “P” trap installed at the base of the air handler. The trap is inverted at the top of the vertical rise.

Typical Installation with Condensing Unit on Top

Optional Hot Gas Reheat

Optional Hot Gas Bypass

Condensate Trap And PipeLoop To Top Of Coil

Suction

Liquid

Slope Down Towards Condensing Unit

Slope Down From Air Handler

Condensate Trap And Pipe

Suction

Liquid Optional Hot Gas

Reheat

Optional Hot Gas Bypass

Page 14: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

14

Dimensions - RCA 051/061/071

A B C D E F G H K L M N P Q R(in) 3.00 47.38 42.25 52.25 0.75 40.38 39.13 2.00 3.50 5.00 9.00 13.00 20.00 3.25 53.38

COIL

CO

IL

CO

NTR

OLS

ELE

CTR

ICA

L

COMPRESSOR

OPTIONAL HOT GAS BYPASS

LIQUIDOPTIONAL HOT GAS REHEAT

SUCTION

G

F

H A K

L MN

P

Q

DC

B

A

Ø E

R

TOP VIEW MULTI-DIMENSIONAL VIEW

SIDE VIEW BACK VIEW

Page 15: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

15

Dimensions - RCA 101/141

ØE

J

COMPRESSOR

ELE

CTR

ICA

L

B

FG

HA

A

CD

A

CO

IL

CO

IL

COIL

SUCTION

Q

N

P

KL

M

OPTIONAL HOT GAS REHEAT

LIQUID

OPTIONAL HOT GAS BYPASS

TOP VIEW MULTI-DIMENSIONAL VIEW

SIDE VIEW FRONT VIEW

A B C D E F G H J K L M N P Q(in) 3.00 68.00 45.50 55.50 0.88 41.38 40.13 49.50 4.00 5.56 8.56 8.38 11.38 14.13 74.00

Page 16: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

16

Dimensions - RCA 171/201/271

A B C D E F G H J(in) 64.25 52.88 51.38 79.00 22.00 25.50 29.00 16.00 21.00

ELECTRICALCOMPRESSOR

B

C

D A

A

COIL

FG

E

HJ

SUCTIONOPTIONAL HOT GAS REHEAT

LIQUID

OPTIONAL HOT GAS BYPASS

TOP VIEW MULTI-DIMENSIONAL VIEW

SIDE VIEW BACK VIEW

Page 17: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

17

Dimensions - RCA 361/421

A B C D E F G H J(in) 101.25 53.63 52.13 84.00 22.00 25.50 29.00 16.00 21.00

GF

A

D A

COMPRESSOR

BC

ELECTRICAL

COIL

SUCTION

OPTIONAL HOT GAS BYPASS

LIQUID

E

J

H

OPTIONAL HOT GAS REHEAT

TOP VIEW MULTI-DIMENSIONAL VIEW

SIDE VIEW BACK VIEW

Page 18: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

18

Reference InformationAmbient Temperature Correction Factors

Ambient Temperature (°F) 85 90 95 100 105 110 115Total Capacity (Btu/h) 1.05 1.03 1.00 0.98 0.95 0.91 0.87

Sensible Capacity (Btu/h) 1.03 1.02 1.00 0.99 0.97 0.97 0.93Electric Power (W) 0.95 0.98 1.00 1.03 1.05 1.08 1.11

Recommended Refrigerant Line Sizes- Air Handler Below Condensing Unit (in OD)

Nominal Capacity (Btu/h)0-25 ft. Equivalent Length 26-50 ft. Equivalent Length

Suction Liquid Hot Gas Reheat

Hot Gas Bypass

Suction Liquid Hot Gas Reheat

Hot Gas Bypass

36,000 5/8, 5/8 3/8 1/2 3/8 3/4, 3/4 1/2 1/2 3/848,000 3/4, 3/4 3/8 5/8 3/8 3/4, 3/4 1/2 5/8 3/860,000 3/4, 3/4 1/2 5/8 1/2 7/8, 7/8 1/2 5/8 1/272,000 7/8, 7/8 1/2 5/8 1/2 7/8, 7/8 1/2 5/8 1/284,000 7/8, 7/8 1/2 3/4 1/2 1-1/8, 7/8 1/2 3/4 1/296,000 7/8, 7/8 1/2 3/4 1/2 1-1/8, 7/8 1/2 3/4 1/2

120,000 1-1/8, 7/8 1/2 3/4 5/8 1-3/8, 1-1/8 5/8 3/4 5/8150,000 1-1/8, 1-1/8 5/8 7/8 5/8 1-3/8, 1-1/8 5/8 7/8 5/8180,000 1-1/8, 1-1/8 5/8 7/8 5/8 1-3/8, 1-3/8 5/8 7/8 5/8220,000 1-3/8, 1-3/8 5/8 1-1/8 3/4 1-3/8, 1-3/8 3/4 1-1/8 3/4250,000 1-3/8, 1-3/8 5/8 1-1/8 3/4 1-3/8, 1-3/8 3/4 1-1/8 3/4300,000 1-3/8, 1-3/8 3/4 1-1/8 3/4 1-5/8, 1-3/8 3/4 1-1/8 3/4360,000 1-3/8, 1-5/8 3/4 1-1/8 7/8 1-5/8, 1-5/8 7/8 1-1/8 7/8420,000 1-5/8, 1-5/8 3/4 1-3/8 7/8 1-5/8, 1-5/8 7/8 1-3/8 7/8

Nominal Capacity (Btu/h) 51-75 ft. Equivalent Length 76-100 ft. Equivalent Length

Suction Liquid Hot Gas Reheat

Hot Gas Bypass

Suction Liquid Hot Gas Reheat

Hot Gas Bypass

36,000 7/8, 5/8 1/2 5/8 1/2 7/8, 3/4 1/2 5/8 N/A48,000 7/8, 3/4 1/2 3/4 1/2 7/8, 7/8 1/2 5/8 N/A60,000 1-1/8, 3/4 1/2 3/4 1/2 7/8, 7/8 1/2 3/4 N/A72,000 1-1/8, 7/8 1/2 3/4 5/8 1-1/8, 7/8 5/8 3/4 N/A84,000 1-1/8, 7/8 5/8 7/8 5/8 1-1/8, 7/8 5/8 3/4 N/A96,000 1-1/8, 1-1/8 5/8 7/8 5/8 1-1/8, 1-1/8 5/8 3/4 N/A

120,000 1-1/8, 1-1/8 5/8 7/8 3/4 1-1/8, 1-1/8 5/8 7/8 N/A150,000 1-3/8, 1-1/8 5/8 1-1/8 3/4 1-3/8, 1-1/8 3/4 7/8 N/A180,000 1-3/8, 1-3/8 3/4 1-1/8 3/4 1-3/8, 1-3/8 3/4 1-1/8 N/A220,000 1-3/8, 1-3/8 3/4 1-1/8 7/8 1-5/8, 1-3/8 3/4 1-3/8 N/A250,000 1-3/8, 1-3/8 3/4 1-3/8 7/8 1-5/8, 1-3/8 7/8 1-3/8 N/A300,000 1-5/8, 1-3/8 7/8 1-3/8 1-1/8 2-1/8, 1-5/8 7/8 1-3/8 N/A360,000 2-1/8, 1-5/8 7/8 1-3/8 1-1/8 2-1/8, 1-5/8 1-1/8 1-3/8 N/A420,000 2-1/8, 1-5/8 1-1/8 1-3/8 1-1/8 2-1/8, 1-5/8 1-1/8 1-5/8 N/A

NOTES: 1. Line sizes are calculated assuming single scroll compressors in Models 051-201 and tandem scroll compressors in Models 271-421. Contact the factory for any other compressor configuration. 2. All piping must comply with standard refrigeration piping techniques. Consult the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Handbook-Refrigeration. 3. Suction, hot gas bypass and hot gas reheat lines should be insulated with a 5/8” minimum thickness closed cell foam insulation. Liquid line exposed to high ambient temperatures should be insulated with a 5/8” minimum thickness closed cell foam insulation. 4. First suction line diameter size is for horizontal runs. Second suction line diameter size is for vertical risers. 5. Maximum suction line vertical lift is 60’. Riser-sized traps are required for every 20’ of vertical riser starting at the lowest point. 6. If ordered, hot gas reheat and hot gas bypass require only one line. 7. Standard hot gas bypass is not recommended for use with greater than 75’ of equivalent line length. Internal hot gas bypass should be used as an alternative. 8. Contact factory for applications with digital scroll compressors. 9. Contact factory for layouts requiring more than 75’ of actual line length.

Page 19: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

19

Reference InformationRecommended Refrigerant Line Sizes- Air Handler Level with or Above Condensing Unit (in OD)

Nominal Capacity (Btu/h) 0-25 ft. Equivalent Length 26-50 ft. Equivalent Length

Suction Liquid Hot Gas Reheat

Hot Gas Bypass

Suction Liquid Hot Gas Reheat

Hot Gas Bypass

36,000 5/8 3/8 1/2 3/8 3/4 3/8 1/2 3/848,000 3/4 3/8 5/8 3/8 7/8 1/2 5/8 3/860,000 3/4 1/2 5/8 1/2 7/8 1/2 5/8 1/272,000 7/8 1/2 5/8 1/2 1-1/8 1/2 5/8 1/284,000 7/8 1/2 3/4 1/2 1-1/8 5/8 3/4 1/296,000 7/8 1/2 3/4 1/2 1-1/8 5/8 3/4 1/2

120,000 1-1/8 5/8 3/4 5/8 1-1/8 5/8 3/4 5/8150,000 1-1/8 5/8 7/8 5/8 1-3/8 3/4 7/8 5/8180,000 1-1/8 3/4 7/8 5/8 1-3/8 3/4 7/8 5/8220,000 1-3/8 3/4 1-1/8 3/4 1-3/8 7/8 1-1/8 3/4250,000 1-3/8 3/4 1-1/8 3/4 1-3/8 7/8 1-1/8 3/4300,000 1-3/8 7/8 1-1/8 3/4 1-5/8 7/8 1-1/8 3/4360,000 1-3/8 7/8 1-1/8 7/8 1-5/8 7/8 1-1/8 7/8420,000 1-5/8 1-1/8 1-3/8 7/8 1-5/8 1-1/8 1-3/8 7/8

Nominal Capacity (Btu/h) 51-75 ft. Equivalent Length 76-100 ft. Equivalent Length

Suction Liquid Hot Gas Reheat

Hot Gas Bypass

Suction Liquid Hot Gas Reheat

Hot Gas Bypass

36,000 3/4 3/8 5/8 1/2 3/4 1/2 5/8 N/A48,000 7/8 1/2 3/4 1/2 7/8 1/2 5/8 N/A60,000 7/8 1/2 3/4 1/2 7/8 1/2 3/4 N/A72,000 7/8 1/2 3/4 5/8 7/8 1/2 3/4 N/A84,000 1-1/8 5/8 7/8 5/8 1-1/8 5/8 3/4 N/A96,000 1-1/8 5/8 7/8 5/8 1-1/8 5/8 3/4 N/A

120,000 1-1/8 3/4 7/8 3/4 1-3/8 5/8 7/8 N/A150,000 1-3/8 3/4 1-1/8 3/4 1-3/8 3/4 7/8 N/A180,000 1-5/8 3/4 1-1/8 3/4 1-3/8 3/4 1-1/8 N/A220,000 1-5/8 7/8 1-1/8 7/8 1-5/8 3/4 1-3/8 N/A250,000 1-5/8 7/8 1-3/8 7/8 1-5/8 7/8 1-3/8 N/A300,000 1-5/8 7/8 1-3/8 1-1/8 1-5/8 7/8 1-3/8 N/A360,000 2-1/8 1-1/8 1-3/8 1-1/8 2-1/8 1-1/8 1-3/8 N/A420,000 2-1/8 1-1/8 1-3/8 1-1/8 2-1/8 1-1/8 1-5/8 N/A

NOTES: 1. Line sizes are calculated assuming single scroll compressors in Models 051-201 and tandem scroll compressors in Models 271-421. Contact the factory for any other compressor configuration. 2. All piping must comply with standard refrigeration piping techniques. Consult the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Handbook-Refrigeration. 3. Suction, hot gas bypass and hot gas reheat lines should be insulated with a 5/8” minimum thickness closed cell foam insulation. Liquid line exposed to high ambient temperatures should be insulated with a 5/8” minimum thickness closed cell foam insulation. 4. Maximum suction line vertical lift is 60’. Loop piping to the top of the coil. 5. Maximum liquid line vertical lift is 60’. 6. If ordered, hot gas reheat and hot gas bypass require only one line. 7. Standard hot gas bypass is not recommended for use with greater than 75’ of equivalent line length. Internal hot gas bypass should be used as an alternative. 8. Contact factory for applications with digital scroll compressors. 9. Contact factory for layouts requiring more than 75’ of actual line length.

Page 20: RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 A.pdf · 2014. 12. 19. · 3 Performance Data Net Cooling Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio

Weather-Rite LLC616 North 5th StreetMinneapolis, MN 55401Telephone: +1.612.338.1401Fax: +1.612.338.6783Toll Free: 1.800.589.3691www.weather-rite.com

Printed in the USA WRRCADSGNA 0114 Rev A

Thank you for your business!

Installation Code and Annual Inspections: All installation and service of WEATHER-RITE™ equipment must be performed by a contractor qualified in the installation and service of equipment sold and supplied by Weather-Rite LLC and conform to all requirements set forth in the WEATHER-RITE™ manuals and all applicable governmental au-thorities pertaining to the installation, service, operation and labeling of the equipment. To help facilitate optimum performance and safety, Weather-Rite LLC recommends that a qualified contractor conduct, at a minimum, annual inspections of your WEATHER-RITE™ equipment and perform service where necessary, using only replacement parts sold and supplied by Weather-Rite LLC.Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is available through WEATHER-RITE™ representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual.There are references on this document to various trademarks. All trademarks mentioned herein, whether registered or not, are the property of their respective owners. Weather-Rite LLC is not sponsored by or affiliated with any of the trademark or registered trademark owners, and make no representations about them, their owners, their products or services. Weather-Rite LLC is not sponsored by or affiliated with BACnet® or LonWorks®.These products (with the exception of the CGTH and UHA[X][S] 30 - 75) are not for residential use.This document is intended to assist licensed professionals in the exercise of their professional judgment.

© 2014 Weather-Rite LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without written permission of Weather-Rite LLC.