ral integration issues
DESCRIPTION
RAL Integration Issues. Elwyn Baynham, Paul Drumm, Yury Ivanyushenkov, Tony Jones RAL. MICE Collaboration Meeting, Osaka, August 1-3, 2004. Scope. Layout Beam height Support structure Beam line shielding layout. MICE layout. Height of MICE beam. Dia 650. Aperture in ISIS wall. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/1.jpg)
1
RAL Integration IssuesRAL Integration Issues
MICE Collaboration Meeting, Osaka, August 1-3, 2004
Elwyn Baynham, Paul Drumm, Yury Ivanyushenkov, Tony Jones
RAL
![Page 2: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/2.jpg)
2
• Layout
• Beam height
• Support structure
• Beam line shielding layout
Scope
![Page 3: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/3.jpg)
3
MICE layout
![Page 4: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/4.jpg)
4
Concrete floor
Support structure
Dia 650Aperture in ISIS wall
1684.2
160*
1524*
Height of MICE beam
![Page 5: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/5.jpg)
5
MICE support structure : Concept
• Requirements/specification: - to move MICE modules out the beam (to the side direction) for various MICE stages
( Qs: Do we need to move ALL modules?; Is the side direction preferable?)
• Accuracy/tolerances: - along the beam +/- 1 mm - across the beam +/- 1 mm
(Q: What position accuracy is required for module-to-module connection ?)
• Adjustment: - adjustment possibility is required.• Locking mechanism: - required.• Loads: - max load is 3 (?) tonnes.• Force transfer function: - gravity force to the floor; - module-to-module axial force to the floor ?
![Page 6: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/6.jpg)
6
MICE support structure : Options
• Commercial rail system: - usually high accuracy (+/- 0.1 mm )
( Q: Do we need it?)
- proven design; - delivery times – days ( if off-the-shelf product);
BUT high cost.
• Simple slides arrangement: - accuracy; - cost; - prototype.
![Page 7: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/7.jpg)
7
HEPCO SL2 stainless steel based slide system
Item Price/each, £ No./MICE Total No. Total price, with VAT, module k£ k£
Stock SL2 carriage (type AU SS L 76) 460 4 28 12.880 15.134 in assembled and adjusted condition
Spacer slide (rail) SS NL 76 Length of 4.5 m in 3-m and 1.5-m sections 2475 2 14 34.650 40.714
Grand total, k£ 55.848
Delivery time: 3-5 days
Hepco Slide Systems Ltd, Devon England EX16 6TG
MICE support structure: Commercial system
![Page 8: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/8.jpg)
8
MICE support structure: Commercial system (2)
![Page 9: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/9.jpg)
9
Concrete floor
Simple slides arrangement
MICE support structure: Alternative solution
Rails
Low-friction material blocks
Sliding carriages
Platform
![Page 10: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/10.jpg)
10
MICE support structure vs. MICE stages
Problem: some of MICE modules will be located in various positions along the beam for different stages of the experiment.
Possible solution: sliding rails (rails on rails).
Concrete floor
Platform
Steel plate
HEPCO rail system
Beam
Bottom rails 20
40
80
20
160*
MICEmodule
![Page 11: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/11.jpg)
11
Beam line and shielding layout
Beam line shielding:
• shields MICE against full beam loss in the ISIS beam pipe (-> 2m of steel is required);
• is removable for access to PSI solenoid;• ideally allows to work on the beam line components in the MICE hall even when the ISIS beam is on -> concept of temporary shielding.
![Page 12: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/12.jpg)
12
Beam line and shielding layout
![Page 13: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/13.jpg)
13
Steel shielding
Concrete shielding17-tonne magnetPSI solenoid
Crane zone limits
ISIS wall
Beam line shielding
Existing steelshielding
![Page 14: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/14.jpg)
14
PSI solenoid support structure and shielding
Concrete ISIS wall
Steelshielding
![Page 15: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/15.jpg)
15
Temporary shielding arrangement
These two magnets are in Off-beam position
PSI solenoid is in Test position
Temporary steel shielding
![Page 16: RAL Integration Issues](https://reader035.vdocuments.us/reader035/viewer/2022081506/56813144550346895d97c211/html5/thumbnails/16.jpg)
16
Next steps
• MICE general layout: - start implementing MICE sub-systems (RF power system, hydrogen system etc.) and magnetic shielding (requires more modelling).
• Support structure: - agree on requirement/specs; - agree on concept; - get cost estimations for various options.
• Beam line and shielding layout: - finish detailed design; - get OK from ISIS Radiation Safety Officer