CERTIFICATECertified Passive House Component
Passive House InstituteDr. Wolfgang Feist64283 Darmstadt
GermanyComponent-ID 0170cw03 valid until 31st December 2017
www.passivehouse.com
Category: Curtain WallManufacturer: RAICO Bautechnik GmbH,
Pfaffenhausen,Germany
Product name: THERM+ 50 S-i T-Profil
This certificate was awarded based on the followingcriteria for the cool, temperate climate zone
Comfort UCW = 0.80 ≤ 0.80 W/(m2 K)UCW ,installed ≤ 0.85 W/(m2 K)with Ug = 0.70 W/(m2 K)
Hygiene fRsi=0.25 ≥ 0.70
CERTIFIEDCOMPONENTPassive House Institute
cool, temperate climate
phAPassive House
efficiency class phE phD phC phB phA
RAICO Bautechnik GmbHGewerbegebiet Nord 2, 87772 Pfaffenhausen, GermanyT +49 8265 911 0 |B [email protected] | Í http://www.raico.de |
20 o
C
18 o
C
16 o
C
14 o
C
12 o
C
10 o
C
8 o
C
6 o
C
4 o
C
2 o
C
0 o
C
-2 o
C
-4 o
C
-6 o
C
-8 o
C
-10 o
C
Calculation model Isothermal
Description
Steel construction wit wedled system carrier. Aluminium covering- and pressure-strip. PE-foam insu-lator in the glazing rebate (0,038 W/(mK)). inside covered by reflecting Aluminium foil (ε=0,05). Plasticglass-carier on stainless steel screws. The losses by the screws werde determined by measurement(ift), the losses caused by the glass carrier by 3D-simulation (PHI). Used Pane: 48 mm (6/16/4/16/6),intersection of the Glass: 12 mm. Used spacer: Swisspacer V
Explanation
The element U-values were calculated for the test element size of 1.20 m× 2.50 m with Ug = 0.70 W/(m2 K).If a higher quality glazing is used, the element U-values will improve as follows:
Glazing Ug = 0.70 0.69 0.58 0.53 W/(m2 K)↓ ↓ ↓ ↓
Element UCW 0.80 0.79 0.69 0.64 W/(m2 K)
Transparent building components are classified into efficiency classes depending on the heat lossesthrough the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, andthe glazing edge lengths are included in these heat losses. A more detailed report of the calculationsperformed in the context of certification is available from the manufacturer.The Passive House Institute has defined international component criteria for seven climate zones. Inprinciple, components which have been certified for climate zones with higher requirements may alsobe used in climates with less stringent requirements. In a particular climate zone it may make senseto use a component of a higher thermal quality which has been certified for a climate zone with morestringent requirements.
Further information relating to certificationcan be found on www.passivehouse.com and passipedia.org.
2/4 THERM+ 50 S-i T-Profil
www.passivehouse.com
Frame width U-value frame Ψ -glass edge Temp. Factorbf Uf
1 Ψg fRsi=0.25Framevalues mm W/(m2 K) W/(m K) [-]
Topfixed
(tof) 50 0.85 0.037 0.81
Sidefixed
(sf) 50 0.85 0.037 0.81
Bottomfixed
(bof) 50 0.85 0.037 0.81
Mullionfixed
(m) 50 0.85 0.037 0.81
Transomfixed
(tf) 50 0.85 0.037 0.81
Spacer: SWISSPACER V Secondary seal: Polysulfide
Thermal glass carrier bridge 2 χGT = 0.006 W/K
1Includes ∆U = 0.19 W/(m2 K). Determined through measurement2Determined through 3D - FEM Simulation . Glas support type : Non-Metallic Glass Carrier with Screws
3/4Component-ID: 0170cw03
www.passivehouse.com
www.passivehouse.com