radiochemistry shielding solutions...lead lined cabinetry shielded workstations contact your...
TRANSCRIPT
RADIOCHEMISTRY SHIELDING SOLUTIONSSHIELDED NUCLEAR RADIATION CONTAINMENT CHAMBERS
2 Visit our web site for up-to-date information & specifications. www.capintec.com / www.mirion.com
Lead-Lined CabinetryRadiochemistry shielding solutions
Everything about Mirion Technologies (Capintec), Inc’s Hot Cells conveys quality. Attention to detail is what you expect from Mirion...and that’s what you get.
Hot cells are required to protect individuals from radioactive isotopes by providing a safe containment box in which they can control and manipulate the equipment required.
When quality and performance count, you deserve the peace of mind that comes from your decision to select our products. For over 50 years, we have been relied on and trusted for all of your nuclear medicine product needs. Now, you can rely on our quality for all of your radiation shielding products!
RADIOCHEMISTRY SHIELDING SOLUTIONS
3
Radiochemistry shielding solutions
CONTENTS
Multiple Function Hot Cell .......................................................... 5
All-In-One Hot Cell ............................................................................ 6
Tele-Tong Hot Cell ..............................................................................7
Production Hot Cell .......................................................................... 8
Dispensing Hot Cell ......................................................................... 9
Manipulator Hot Cell ......................................................................10
Dual Synthesis Hot Cell .................................................................11
Bio-Safety Cabinet ...........................................................................12
Radiation Fume Hoods .................................................................13
CAP-Cell® Isolator ............................................................................14
Elution Dispensing Safety Cabinet ......................................16
Recommended Products ............................................................. 17
Additional Great Capintec™ Products .................................18
4 Visit our web site for up-to-date information & specifications. www.capintec.com / www.mirion.com
Radiochemistry shielding solutions
WE HAVE MORE SOLUTIONS FOR YOUR POSITRON EMISSION TOMOGRAPHY (PET) NEEDSMirion provides a full line of Capintec PET products including, hot cells, mini cells, shielded hoods, calibrators, dose drawing stations and personnel shielding. In addition, our engineers are glad to work with you to design the product that best meets your needs.
Pass-Thru Wall Systems
PET SoftwareWaste Containers and Brick Kits
Dose Drawing Station
Shielding Accessories
Dose Calibrators
Lead Lined Cabinetry
Shielded Workstations
Contact your Capintec Account Manager for more information to customize a PET solution for you at 201-825-9500 or email us at: [email protected]
5
Radiochemistry shielding solutions
Lead glass viewing window
HEPA pressure gauge
Smart touch control panel
Lead glass viewing window
Air ventilated pass-through
drawer
Air ventilated product drawer and lifter
Trays
Tongs
Shielded glove ports
Shielded door
ITEM NUMBERSMultiple Function Hot Cell (75/75 mm lead shielding) 5730-00001
Multiple Function Hot Cell (75/60 mm lead shielding) 5730-00002
Multiple Function Hot Cell (60/50 mm lead shielding) 5730-00003
FEATURES: • An innovative vacuum sealing
technology ensures chamber air tightness.
• A HEPA filter is equipped to ensure the air quality complies with Grade A (Class 100/ISO 5).
• The Smart Touch Control Panel integrates all operating functions and real-time monitoring of temperature, humidity, air pressure, air flow rate, air change rate, and radiation level.
• It is perfect for daily production and also ideal for research operations
DIMENSIONS: • External Size: 270 cm x 120 x 120
cm (H x W x D) • Internal Size: 65 x 96 x 77 x cm
(H x W x D) • Weight: 6800 kg (lead thickness
60 mm on front side, and 50 mm on back and other sides.)
MULTIPLE FUNCTION HOT CELLThe multiple function hot cell has two operation platforms both with lead glass viewing windows. One equipped with two shielded glove ports, another equipped with one tong. It is available for two operators to handle the isotope simultaneously. It is not only for research purpose but also for GMP production.
6 Visit our web site for up-to-date information & specifications. www.capintec.com / www.mirion.com
Radiochemistry shielding solutions
FEATURES: • The working chamber is SUS 316 stainless steel with
rounded corners to minimize dust accumulation. The external surface is SUS 304 stainless steel.
• 75 mm of lead shields the front of the hot cell. All other sides have 60 mm or 75 mm of lead shielding.
• The Laminar Flow Dispensing Chamber includes HEPA filtration that provides air quality to comply with Grade A (Class 100/ISO 5).
• Unidirectional air flow in the Synthesis Chambers have HEPA filtration to comply with Class C or B (depending on the lab environment) requirements. Exhaust air passes through charcoal filtration.
• An innovative air vacuum technology system seals the inner containment door to ensure air tightness.
• The Smart Touch Control Panel integrates all operating functions and real-time monitoring information.
• The front of the Dispensing Cell has a lead glass viewing window and a tele-tong. The Synthesis Cells have a viewing CCTV monitor on the upper shielded hinged door.
• A shielded sliding door located on the side of the Dispensing Cell enables easy movement of material or products between the cells.
• The Dispensing Cell has a side door with a shielded glove port. An air ventilated lifter is equipped below the glove port to ensure the material and product deliver in or out the clean air chamber without cross contamination.
• Radiation detectors measure the level of activity in each working chamber. When the radiation exceeds a preset safety level the interlock system prevents the door from opening (optional).
• It accommodates auto dispensers ADG-500 and ADG-500S.
DIMENSIONS: • External Size: 270 x 180 x 113 cm (H x W x D) • Internal Size:
– Dispensing Chamber: 70 x 60 x 79 cm (H x W x D) – Synthesis Chamber: 65 x 70 x 64 x cm (H x W x D)
• Weight: 11800 kg
ALL-IN-ONE HOT CELLIt consists of dual synthesizing cell and a dispensing cell to save space and cost, as well as comply with GMP guidelines. It is ideal for upgrading or renovating your current laboratory to achieve GMP requirement.
ITEM NUMBERSAll-In-One Hot Cell (75/60/50 mm lead shielding) 5730-00004
All-In-One Hot Cell (75/75/60 mm lead shielding) 5730-00005
Smart Touch Control Panel
7
Radiochemistry shielding solutions
FEATURES: • The working chamber is SUS 316 stainless steel with
rounded corners to minimize dust accumulation. The external surfaces are SUS 304 stainless steel.
• 75 or 60 mm of lead shields the front of the hot cell. All other sides have 75, 60 or 50 mm of lead shielding.
• The Laminar Flow Dispensing Chamber has HEPA filtration that provides air quality to comply with Grade A (Class 100/ISO 5).
• An innovative air vacuum technology system seals the inner containment door to ensure air tightness.
• The Smart Touch Control Panel integrates all operating functions, real-time monitoring information and readings from the dose calibrator.
• The hinged front door has a lead glass viewing window. • Two tongs enable manipulative work in the dispensing
area. • A product elevator enables materials or products to
be moved into and out of the dispensing area without contamination.
• A 60 mm lead dose calibrator housing is equipped below the working level.
• A radiation detector measures the radioactivity level in the working chamber. When the radiation exceeds a preset safety level the interlock prevents the doors from opening (optional).
• It accommodates auto dispensers ADG-500, ADG-500S, MVD-20, and APDS.
DIMENSIONS: • External Size: 240 x 120 x 130 cm (H x W x D) • Internal Size: 80 x 92 x 87 cm (H x W x D) • Weight:
– 7800 kg (75/60 mm lead shielding) – 6800 kg (75/60/50 mm lead shielding)
TELE-TONG HOT CELLIt is equipped with two tele-tongs for handling and processing isotope and radiopharmaceuticals under Grade A (Class 100/ISO 5) environment to comply with GMP regulations.
Smart Touch Control Panel
ITEM NUMBERSTele-Tong Hot Cell (75/60 mm lead shielding) 5730-00006
Tele-Tong Hot Cell (75/60/50 mm lead shielding) 5730-00007
Tele-Tong Hot Cell (75/75 mm lead shielding) 5730-00008
8 Visit our web site for up-to-date information & specifications. www.capintec.com / www.mirion.com
Radiochemistry shielding solutions
FEATURES: • The working chamber is SUS 316 stainless steel with
rounded corners to minimize dust accumulation. The external surfaces are SUS 304 stainless steel.
• 75 or 60 mm of lead shields the front of the hot cell. All other sides have 75, 60 or 50 mm of lead shielding.
• The Laminar Flow Dispensing Chamber has HEPA filtration that provides air quality to comply with Grade A (Class 100/ISO 5).
• An innovative air vacuum technology system seals the inner containment door to ensure air tightness.
• The Smart Touch Control Panel integrates all operating functions, real-time monitoring information and readings from the dose calibrator.
• The hinged front door has a lead glass viewing window. • Two shielded glove ports and one tele-tong enable
manipulative work in the dispensing area. • An air ventilated product elevator enable materials or
products to be moved into and out of the dispensing area without contamination.
• A 60 mm lead dose calibrator housing is equipped below the working level.
• A radiation detector measures the radioactivity level in the working chamber. When the radiation exceeds a preset safety level the interlock prevents the doors from opening (optional).
• It is ideal for accommodating auto dispenser MVD-20.
DIMENSIONS: • External Size: 260 x 152 x 120 cm (H x W x D) • Internal Size: 65 x 120 x 75 x cm (H x W x D) • Weight: 7800 kg
PRODUCTION HOT CELLThis hot cell is equipped with two shielded glove ports, one tele-tong, and two lead glass viewing windows in the front. It is available for two operators to handle the isotopes simultaneously. It is not only for research purpose but also for GMP production.
Smart Touch Control Panel
ITEM NUMBERSProduction Hot Cell (75/60 mm lead shielding) 5730-00009
Production Hot Cell (60/50 mm lead shielding) 5730-00010
Production Hot Cell (75/75 mm lead shielding) 5730-00011
9
Radiochemistry shielding solutions
FEATURES: • The working chamber is SUS 316 stainless steel with
rounded corners to minimize dust accumulation. The external surfaces are SUS 304 stainless steel.
• The front face of the hot cell is shielded with either 75 or 60 mm of lead. All other sides have 75, 60, or 50 mm of lead shielding.
• The Laminar Flow Dispensing Chamber has HEPA filtration that provides air quality to comply with Grade A (Class 100/ISO 5).
• An innovative air vacuum technology system seals the inner containment door to ensure air tightness.
• The Smart Touch Control Panel integrates all operating functions, real-time monitoring information, and readings from the dose calibrator.
• The hinged front door has a lead glass viewing port and two shielded glove ports (the gloves are not shielded).
• Air ventilated elevator functioning in a Class 100 environment enable materials to be transferred into and out of the dispensing area without contamination.
• A 60 mm lead dose calibrator housing is equipped below the working level.
• A GM detector measures the radioactivity level in the working chamber. When the radiation exceeds a preset safety level the interlock prevents the doors from opening (optional).
• It accommodates auto dispenser ADG-2000.
DIMENSIONS: • External Size:
– 240 x 113 x 110 x cm (H x W x D) (75/60 mm lead shielding)
– 260 x 113 x 110 x cm (H x W x D) (75/60 or 50 mm lead shielding)
• Internal Size: 70 x 88 x 70 x cm (H x W x D) • Weight: 6500 kg
DISPENSING HOT CELLThis hot cell is for operators to handle the lower activity radiopharmaceuticals or isotopes through two shielded glove ports either by an automatic or semi-auto dispenser. It is ideal for PET center or nuclear medicine department to dispense the radiopharmaceuticals from bulk vial into syringes (unit dose) in a Grade A (Class 100/ISO 5) environment to comply with GMP.
Smart Touch Control Panel
ITEM NUMBERSDispensing Hot Cell (75/60 mm lead shielding) 5730-00012
Dispensing Hot Cell (60/50 mm lead shielding) 5730-00013
Dispensing Hot Cell (75/75 mm lead shielding) 5730-00014
10 Visit our web site for up-to-date information & specifications. www.capintec.com / www.mirion.com
Radiochemistry shielding solutions
FEATURES: • The working chamber is SUS 316 stainless steel with
rounded corners to minimize dust accumulation. The external surfaces are SUS 304 stainless steel.
• The front face of the hot cell is shielded with either 60 or 75 mm of lead. All other sides have 50, 60, or 75 mm of lead shielding.
• The Laminar Flow Dispensing Chamber includes HEPA filtration that provides air quality to comply with Grade A (Class 100/ISO 5).
• An innovative air vacuum technology system seals the inner containment door to ensure air tightness.
• The Smart Touch Control Panel integrates all operating functions, real-time monitoring information, and readings from the dose calibrator.
• The hinged front door has a lead glass viewing window. • A pair of manipulator is equipped for handling and
processing the isotope or radiopharmacy under Grade A condition (optional).
• Air ventilated elevator functioning in a Class 100 environment enable materials to be transferred into and out of the dispensing area without contamination.
• A 60 mm lead dose calibrator housing is equipped below the working level.
• A GM detector measures the radioactivity level in the working chamber. When the radiation exceeds a preset safety level the interlock prevents the doors from opening (optional).
• It accommodates dispensers ADG-500, ADG-500S, MVD-20, and APDS.
DIMENSIONS: • External Size: 270 x 140 x 130 x cm (H x W x D) • Internal Size: 100 x 100 x 80 x cm (H x W x D) • Weight: 8200 kg
MANIPULATOR HOT CELLCan be equipped with a pair of manipulators for handling and processing the high activity isotopes or radiopharmaceuticals under Grade A (Class 100/IOS 5) environment to comply with GMP regulations.
Smart Touch Control Panel
ITEM NUMBERSManipulator Hot Cell (60/50 mm lead shielding) 5730-00015
Manipulator Hot Cell (75/60 mm lead shielding) 5730-00016
Manipulator Hot Cell (75/75 mm lead shielding) 5730-00017
11
Radiochemistry shielding solutions
FEATURES: • The working chambers are SUS 316 stainless steel with
rounded corners to minimize dust accumulation. The external surfaces are SUS 304 stainless steel.
• 75 mm of lead shields the face of the hot cell. All other sides can be supplied with 60 mm or 75 mm lead shielding.
• A unidirectional air flow system in the synthesis chamber passes through a HEPA filter to ensure compliance with Classes C or B (depending on the lab environment). Exhaust air passes through a charcoal filter.
• An innovative air vacuum technology system seals the inner containment door to ensure air tightness.
• The Smart Touch Control Panel integrates all operating functions and real-time monitoring information.
• Hinged front doors allow complete access to the working chambers.
• A video monitor displays the output from a CCTV installed in each cell.
• A GM detector measures the radioactivity level in the working chamber. When the radiation exceeds a preset safety level the interlock prevents the doors from opening (optional).
• The optional side chamber with 20 mm of lead shielding is available as optional.
DIMENSIONS: • External Size:
– 260 x 102 x 107 cm (H x W x D) (75/60 mm lead shielding)
– 260 x 150 x 107 x cm (H x W x D) (75/60 mm lead shielding with 20 mm lead shielded side chamber)
• Internal Size: – 100 x 72 x 80 x cm (H x W x D) (75/60 mm lead shielding)
– 68 x 72 x 65 x cm (H x W x D) (75/60 mm lead shielding with 20 mm lead shielded side chamber)
• Weight: – 8200 kg (75/60 mm lead shielding) – 9000 kg (75/60 mm lead shielding with 20 mm lead shielded side chamber)
DUAL SYNTHESIS HOT CELLThis hot cell has two segregated cabinets to accommodate two chemical modules (chemical synthesizer) in a vertical position. The shielded side cabinet is ideal to enlarge the space for placing the accessories of chemical modules or as a transfer box to delivery material or product in/out the hot cell.
Smart Touch Control Panel
ITEM NUMBERSDual Synthesis Hot Cell (75/60 mm lead shielding) 5730-00018
Dual Synthesis Hot Cell (75/75 mm lead shielding) 5730-00019
Dual Synthesis Hot Cell (60/50 mm lead shielding) 5730-00029
12 Visit our web site for up-to-date information & specifications. www.capintec.com / www.mirion.com
Radiochemistry shielding solutions
BIO-SAFETY CABINET
ITEM NUMBERS4 ft. Shielded A2 Bio-Safety Cabinet with Sliding L-block
5730-30342
4 ft. Shielded B2 Bio-Safety Cabinet with Sliding L-block
5730-30346
6 ft. Shielded A2 Bio-Safety Cabinet with Sliding L-block
5730-30350
6 ft. Shielded B2 Bio-Safety Cabinet with Sliding L-block
5730-30354
Whether your requirement is for an eighth of an inch of lead surrounding a work area or 2.38 in. (60 mm) of PET thick shielding and an integral lead glass mobile body shield for quality assurance or dose preparation, we can design custom hood shielding to your specifications. If you are not sure of an exact shielding design, contact us for typical design characteristics, specifications and pricing.
The photo on this page is a fully shielded Laminar Flow Hood and Radioisotope Fume Hood. These units feature a mobile body shield with lead glass, to view the working area while protecting the worker. The mobile body shield can be moved to allow replacement of filters and to service the hood. The mobile body shield, although weighing several hundred pounds, moves smoothly into place or out of the way. Our mechanical engineers will be glad to work with you to design the product that suits your application best.
FEATURES: • Standard shielding is 1 ft. or 2 in. with custom shielding
available • Optional lead glass mobile body shield • Flush mounting for dose calibrator ion chambers • Environmental shielding for dose calibrator or other
equipment • 4 ft. (122 cm) and 6 ft. (183 cm) configurations available.
Note that dimensions vary with shielding selection • NSF listed • Optional UV lighting
As a leading manufacturer of shielded enclosures for a variety of Nuclear Medicine, PET and 511 SPECT applications, our Capintec products can provide custom shielding for any of the hoods or enclosures listed on these pages.
13
Radiochemistry shielding solutions
RADIATION FUME HOODS
The hoods are constructed of type 304 stainless steel and include an integral bottom with cup sink option. The one piece interior is free of joints, cracks, or crevices which prevents buildup of residue and simplifies decontamination procedures. These radiation fume hoods can be configured for a seated or standing working height. Because of the unique air flow and accessory requirements that are typical for radiation fume hood applications please contact us to discuss your special needs.
ITEM NUMBERRadiation Fume Hood 4 ft. 5730-0025
FEATURES: • Capintec hood offers both shielded and standard
configurations • 4 and 6 ft. widths available • 1 and 2 in. lead shielding also available • Custom configuration services available • Optional integrated mobile lead glass work shields • Three remotely controlled service fixtures • Dedicated remote blower for superior exhaust
characteristics
Radiation Fume Hoods in a wide variety of configurations are now available from Mirion.
14 Visit our web site for up-to-date information & specifications. www.capintec.com / www.mirion.com
Radiochemistry shielding solutions
FEATURES:Isolator: • Sealed glove box design with sealed interchange chamber • Unit shall maintain ISO Class 5 (Federal Standard 209E
Class 100) within workzone and interchange chamber • Negative pressure, with sufficient interchange chamber
pressure differential to maintain sterility in glove box • Interchange door is interlocked to prevent inadvertent
opening when outer door is open • Two removable work trays with cove corners for main and
interchange chambers • HEPA filter for supply air protected by non-flammable
perforated metal diffuser • HEPA filter seal is spring loaded Neoprene • Partial recirculating or total exhaust choice • Externally mounted fluorescent lighting • Hospital grade duplex outlet on back wall with drip proof
cover • Hinged front face, ergonomically slanted at 10° from
vertical • 16 GA, Type 304 stainless steel liner with reinforced U
channels • Top/Front filter removal access without disassembly of
control panel • Two 8 in. diameter glove ports • Two circular nitrile rubber gloves • Two circular nitrile rubber sleeves • Three position IV bar with six hooks • Key locks included on external front face
CAP-CELL® ISOLATORThe Capintec CAP-Cell® Isolator is designed to provide an ISO Class 5 (Class 100) clean air environment to meet the new and more stringent requirements of USP <797> for aseptic sterile compounding.
ITEM NUMBERSCAP-Cell with .125 in. lead 5530-3140
CAP-Cell with .25 in. lead 5530-3141
This shielded negative pressure recirculating isolator is the ideal system for compounding and dispensing injectable Nuclear Medicine radiopharmaceuticals. The unit incorporates a sealed glove box and interchange chamber, with .125 in. (optional .25 in.) of lead shielding to front door, sides, and floor. Additional shielding on front face provides a full .25 in. lead body shield. The sealed isolator also eliminates the costly requirement for placement in an exterior ISO Class 7 (Class 10,000) clean room. The standard system uses HEPA filtered air with partial recirculation and room air exhaust. This feature eliminates the need for HVAC hookup and reduces operating costs. Optional external exhaust accessories are available for HVAC hookup if desired. The model has a fully hinged front panel to allow easy access for cleaning and equipment placement. The sealed interchange chamber allows the user to transfer materials without compromising the air quality of the primary cell.
15
Radiochemistry shielding solutions
Shielding/Base • Viewing window: 1/2 in. of 4.8 g/cm3 leaded glass, 25 in. wide
x 7 1/2 in. height • .125 in. lead shielding on base, back and sides
(optional .25 in.) • .125 in. lead shielding on hinged front panel excluding glove
ports and viewing window • .25 in. lead body shield in center of front panel • Base penetrations are sized for sharps container and flush
mount dose calibrator chamber • .125 in. lead shielding for sharps container (Optional .25 in.) • Articulating arm for calibrator readout mounted on base • Exterior steel cosmetic panels painted epoxy enamel • Heavy duty base support-adjustable height with 10 in. range • Height adjustment to center of glove port – 42.5 in. to 52.5 in. • Electrical/Control Panel • Exhaust interlock to prevent positive pressure workzone and
interchange • Centrally located control panel for adjustable airflow and
lights • Airflow adjustment via solid state motor voltage regulator • Fuses located in control panel • Two Minihelic gauges • Meets UL requirements for U.S. and Canada for electrical
safety • UL/UL-C Listed 115 V, ac 60 Hz, 6 Amps (220 V/50 Hz option) • 12 ft. Hospital Grade Power Cord • Exhaust rate 65 CFM (110 CMH) @ 0.1 in. w.g. (external exhaust
option only)
Installation • Unit is designed for customer installation • Disassembled unit will fit through standard 36 in. doorway • Base adjustment must be set before placing shielded glove
box
Options • Thimble kit for external exhaust • Additional lead shielding (1/4 in. total) on sides, floor, and
sharps shield
DIMENSIONS: • Overall Dimensions:
– 80.5 - 90.5 x 51.5 x 31 in. (204.4 - 229.9 x 130.8 x 78.7 cm) (H x W x D), depending upon adjustable base setting
• Workzone Dimensions: – Main Cell 27.375 x 35.25 x 23.25 in. (89.5 x 59 x 69.5 cm) (H x W x D)
• Interchange Chamber Dimensions: – 27.375 x 14.125 x 24 in. (35.8 x 60.9 x 69.5 cm) (H x W x D)
• Interior sliding door: – 8.5 x 18 in. (21.6 x 45.7 cm) (H x W)
• Weight: – .125 in. 1,200 lb. (.3175 cm 544 kg) – .25 in. option 1,600 lb. (.635 cm 725.7 kg)
16 Visit our web site for up-to-date information & specifications. www.capintec.com / www.mirion.com
Radiochemistry shielding solutions
FEATURES: • The internal chamber is SUS 316 stainless steel with round
concerns to prevent dust accumulation and chemical erosion. The external body is carbon steel with epoxy painting.
• The working chamber is shielded by 5 mm thickness of lead, the front top is shielded by lead glass.
• Two sliding lead glasses and two side foldable lead glasses are equipped on the front of working area to prevent radiation exposure to worker.
• A moveable generator cart with 50 mm lead shielded is equipped on front. It may accommodate two generators.
• A dose calibrator housing with 30 mm lead shielding is built beneath the working level.
• The laminar flow with HEPA filter is equipped to meet the IOS 5 air cleanliness (or Federal Standard 209E Class 100).
• The exhausted air passes through a charcoal filter with 70% recycled and 30% exchanged air.
• A touch control panel integrated all the functions is equipped on front top.
• It accommodates dispenser MADD-3, ADS-100, 02-A201.
DIMENSIONS: • External Size: 225 x 150 x 90 cm (H x W x D) • Internal Size: 70 x 120 x 70 cm (H x W x D) • Weight: 750 kg
ELUTION DISPENSING SAFETY CABINETThis is an ideal solution for elution, compounding and dispensing the SPECT or low activity PET drugs in a Class 100 air environment to comply with USP 797 regulations in an imaging center, or unit dose distribution pharmacy.
ITEM NUMBERElution Dispensing Safety Cabinet 2500-6405
17
Radiochemistry shielding solutions
RECOMMENDED PRODUCTS
ITEM NUMBERS1 cc 4300-00302 cc 4300-10593 cc 4300-00315 cc 4300-003210 cc 4300-0033
ITEM NUMBER5130-2086
ITEM NUMBER0665-0002
ITEM NUMBER5550-0002
ITEM NUMBER5130-2090
ITEM NUMBER5530-2017
ITEM NUMBERS1 cc 4300-00342 cc 4300-00603 cc 4300-00355 cc 4300-003610 cc 4300-0037
ITEM NUMBERSW/Body Shield 5510-3003
No Body Shield 5510-3004
ITEM NUMBERS5 cc 0665-201710 cc 0665-201120 cc 0665-2018
ITEM NUMBER0665-2014
ITEM NUMBER5530-2077
ITEM NUMBERS5 cc 0665-202010 cc 0665-201520 cc 0665-2021
ITEM NUMBERSPIG-30 5730-2030PIG-50 5730-2027
ITEM NUMBER0550-0003
ITEM NUMBER5530-2014
Mini L-Shield
T-Vial Shield
Stainless Steel L-Shield
C-Tec™ Syringe Shield
Standard L-Shield
PIN-TEC™ Syringe Shield
Illuminated Vial Shield
511 Spring Armed Dose Drawing Station
511 Adjustable L-Block Table Top Shield511 L-Block Table Top Shield511 C-Tec Syringe Shield
511 C-Tec Syringe Shield Universal 511 T-Vial Shield PIG-30 and PIG-50
511 Dose-Drawing Syringe Shield
18 Visit our web site for up-to-date information & specifications. www.capintec.com / www.mirion.com
Radiochemistry shielding solutions
Recommended Productscontinued
ADDITIONAL GREAT CAPINTEC™ PRODUCTS
ITEM NUMBERSHL System 5130-30255
RPh System 5130-30256HL Chamber 5130-20253
RPh Chamber 5130-20254
ITEM NUMBERSWith PC Software 5250-0022
Without PC Software 5250-0031
ITEM NUMBER5430-3136
ITEM NUMBER5250-0212
ITEM NUMBER5130-2216
CAPRAC-t™ Wipe Counter
CapTLC™ Scanner
CRC®-PC Smart Chamber
CRC®-55tw Dose Calibrator
CAP-RAD™ Area Monitor
19
Radiochemistry shielding solutions
Capintec is a leading worldwide supplier of energy measurement products and services. Capintec is dedicated to continuous quality improvement that leads to uncompromising quality in the development of the most advanced technology and services in the industry.
For over 50 years, Capintec has been recognized as a world leader in the development, manufacturing and marketing of state-of-the-art radiation measuring and monitoring instrumentation. With thousands of instruments in use world-wide, the company continually provides new and innovative solutions to applications in nuclear medicine, nuclear cardiology, oncology, endocrinology, diagnostic radiology, and radiation therapy, the company continues to grow.
CAPINTEC IS LOCATED IN FLORHAM PARK, NEW JERSEY7 Vreeland Road, Florham Park, NJ 07932201.825.9500 or 800.631.3826
ISO 13485 CERTIFIEDWe are proud to state that we have received ISO 13485 certification.
This attests to the seriousness with which we approach quality control, and it allows us to continue CE listings of our products for the international market. Together with the new and expanded FDA Quality System Regulation, Capintec continues to provide our customers with the highest quality products and systems available.
AS OUR QUALITY POLICY STATES:Capintec will be the leading worldwide supplier of energy measurement products and services of uncompromising quality, on time, to our customers. We will do this by using the best technology and people in the industry, while striving for continuous improvement.
ISO certification validates our effort to provide our customers with the highest quality products available.
OPS-1843 - 05/2020
Copyright © 2020 Mirion Technologies, Inc. or its affiliates. All rights reserved. Mirion, the Mirion logo, and other trade names of Mirion products listed herein are registered trademarks or trademarks of Mirion Technologies, Inc. or its affiliates in the United States and other countries. Third party trademarks mentioned are the property of their respective owners.
7 Vreeland Road, Florham Park, NJ 07932201.825.9500 or 800.631.3826
www.capintec.com
www.mirion.com