quick reference guide spain4. in alarm data, choose on which category of equipment, part and data...
TRANSCRIPT
© 2
016
-201
7 M
arpo
rt. A
ll R
igh
ts r
eser
ved.
No
part
of
this
doc
umen
t m
ay b
e re
prod
uced
, sto
red
in a
ret
riev
al s
yste
m o
r tr
ans-
mit
ted
in a
ny
form
by
any
mea
ns;
ele
ctro
nic
, mec
han
ical
, ph
otoc
opyi
ng
or o
ther
wis
e,
wit
hou
t th
e ex
pres
s w
ritt
en p
erm
issi
on f
rom
Mar
port
. “M
arpo
rt”,
th
e M
arpo
rt lo
go
and
Soft
war
e D
efin
ed S
onar
are
reg
iste
red
trad
emar
ks o
f M
arpo
rt. A
ll o
ther
bra
nds
, pr
oduc
ts a
nd
com
pan
y n
ames
men
tion
ed a
re t
he
trad
emar
k an
d pr
oper
ty o
f it
s re
-sp
ecti
ve o
wn
ers
only
. Mar
port
is a
div
isio
n o
f A
irm
ar T
ech
nol
ogy
Corp
orat
ion
.
Offi
ces
Icel
and
Mar
port
EH
F Fo
ssal
eyn
i 16
11
2 R
eykj
avík
, Ice
lan
d
supp
orti
cela
nd@
mar
port
.com
USA
Mar
port
Sto
ut I
nc.
USA
1212
3 H
arbo
ur R
each
Dri
veM
ukil
teo,
WA
982
75 U
SA
supp
ortu
sa@
mar
port
.com
Fran
ceM
arpo
rt F
ran
ce S
AS
Parc
Tec
hn
olog
ique
de
Soye
, Es
pace
MED
IA, 2
Rue
Gal
ilée
56
270
Ploe
meu
r, F
ran
ce
supp
ortf
ran
ce@
mar
port
.com
Spai
nM
arpo
rt S
pain
SR
L Ca
min
o Ch
ouzo
1 3
620
8 V
igo
(Pon
teve
dra)
Sp
ain
su
ppor
tspa
in@
mar
port
.com
QU
ICK REFERENCE G
UIDE
• D
isplay up to four simultan
eous echogram
presentation
s on a
single page.
• U
se drag and drop possibilities to custom
ize your page layout.•
Choose from
existing gauges, h
istograms or 3D
views or create
your own
layout with
any n
umber of sen
sors displayable on
screen.
• A
djust win
dows an
d graphs accordin
g to your needs.
• Com
pare data from equivalen
t sensors usin
g existing m
ultiple h
istory plots.•
Easily play back recorded data.
Scala collects, processes, stores and displays data sen
t from
multiple sen
sors, sounders an
d other con
nected devices.
In order to suit th
e workin
g condition
s, gear and sen
sor data type available, th
is mon
itoring system
offers un
paralleled flexibility.
It is easily confi
gurable:
Mac Basics
Switch
ing on
:
Open
ing application
s and fi
les via the Dock:
Switchin
g off:
Window
s
Open
ing a page in
a new
win
dowR
ight-click the page nam
e, click Move to N
ew W
indow
an
d drag the new
win
dow to an
other screen.
Movin
g pages between
win
dows
From the m
ain w
indow
, right-click a page nam
e and
click Move to W
indow
2 (or 3, 4...). O
r from w
indow
2, right-click a page nam
e and click
Move to M
ain W
indow
.
If you closed a secondary w
indow
, you can fi
nd it back
from the m
enu:
Main
win
dow =
Control pan
els
Troubleshooting
Problem
Possible causes
SolutionSen
sor data are n
ot displayed, LED
s are red or oran
ge.
You may h
ave closed th
e virtual m
achine th
at an
alyzes receiver data w
hen you
started Scala or w
hen you plugged
in a device.
1. Check if this icon
is in
the D
ock. If not, restart
the system.
A virtual m
achine starts
automatically w
hen startin
g the com
puter and is
necessary for Scala
function
ing. T
he virtual m
achin
e win
dow can
appear w
hen startin
g Scala. D
o not close it.
I cann
ot fi
nd a
win
dow.
You may h
ave closed th
e w
indow
.
Click Men
u >
Open
W
indow
X
I can
not
see pages that w
ere displayed before on
the top toolbar.
You may h
ave m
oved these pages to a n
ew
win
dow.
1. Check th
e other win
dows
to see if the page appears
in it. If you created a
win
dow an
d cann
ot fi
nd it, see the previous
troubleshootin
g case.2. If the page is in
another
win
dow, right-click the
page nam
e and select
Move to M
ain W
indow
to m
ove it to the w
indow
w
ith the con
trol panels,
or Move to W
indow
X
to move it to an
other w
indow
.You m
ay have
closed this page
(Customize m
ode on
ly)
If the page was saved in
Custom
Pages, you can fi
nd
it back in the Custom
Pages list. Click th
e plus icon on
the toolbar.
A V
Mw
are Fusion
m
essage appears w
hen
addin
g a n
ew U
SB
key.
This m
essage is due to the virtual m
achine.
It appears when
addin
g external
an U
SB device.
1. Select Rem
ember m
y ch
oice and do n
ot ask again
.2. Click C
onn
ect to Mac.
I cann
ot con
nect
to the
intern
et.
Intern
et netw
ork m
ight be too far in
the n
etwork
list.
1. From th
e top left corner
of the screen click A
pple M
enu
> System
P
references >
Netw
ork.2. From
the bottom
of the
netw
ork list, click the
wh
eel icon an
d select Set Service O
rder.
3. D
rag the n
etwork you use
to have intern
et on top
of the list. It can be for
example your ph
one W
iFi, your router W
iFi, a USB
to Ethern
et adapter...
SCALA
MA
RPORT
Th
is guide is an in
troduction to Scala. If you w
ant to learn
more about
confi
guration an
d advanced custom
ization of display, see Scala U
ser G
uide.
Starting Scala
• Scala softw
are dongle m
ust always be plugged in
the com
puter.
From th
e Dock at th
e bottom of the screen
, click Scala icon
.
Th
e followin
g win
dow is a softw
are that analyzes
sensors data. T
his program
is necessary for the
function
ing of th
e receiver. D
O N
OT
CLO
SE th
is win
dow.
If it appears, click min
imize
to hide it. This icon
sh
ould always appear at th
e bottom of your desktop
screen:
If you close the w
indow
, restart the system.
Scala_qrg / R
ev1
Alarms
Incoming Data
Control PanelsData Display
Receiver Activity
Toolbar for Page Display
Menu
EchogramTime Stamp
3D view of trawl doors If you have sensors placed on your trawl doors, you can display a 3D view of the doors to see their mouvements.To create a new page with the view of the doors:
1
2
Examples of data you can display
Echogram In the part Sensors Data of the control panels, Sonar Data correspond to echograms.Echograms are a representation of what is detected by the sensors with the acoustic signals. The strength of a detected target is expressed in Decibels (dB), that correspond to specific colors on the echogram. Blue usually represents the lowest target strengths and red the highest target strengths.To add an echogram, click + drag Sonar Data to a page.
Scroll to zoom in and out of the echogram. To change colors, right-click the echogram and select Show Palettes.
Data received from sensors are displayed on pages. Pages are organized in tabs on the top toolbar.
To edit pages, first click the menu, then Customize. Enter the password eureka.
Adding data to a page1. Open the control panels: click the small rectangle at the right side of the
screen.2. From Sensors Data, you can see the name of the sensors (e.g. Catch,
Trawl Explorer, Spread Master...) and data they receive (e.g pitch, roll, depth...). Click one tab to display the corresponding
page.
Multiple history plotsYou can add multiple data in one history plot in order to easily compare different data at the same time.1. From Sensors Data in the control
panel, click + drag data, for example Depth from a Trawl Explorer, to a page.
2. From the window that appears, select History Plot.
3. Drag other similar data, for example Depth from a Spread Master, to the first Depth history plot.
4. The second data appear in the history plot in another color.
When you have finished customizing pages, you need to deactivate the Customize mode: click Menu > Customize again.
Removing data from a pageRight-click data element and select Remove.
Saving a pageIf you made changes to a page, you need to save them.1. Right-click the page tab and select Save in Custom Pages.
2. From the Save page template as dialog box, click Save.3. The page is added to the Custom Pages. To see them, click the icon on
the top toolbar.
4. Right-click the page tab again and select Save Page Changes.
Receiver is active
Receiver is detected
The communication with the receiver has just been lost. There is a connection problem.
The communication with the receiver has been lost for at least 20 seconds.
1. Click Menu > Settings2. Select the tab Alarms.3. Click Add.
4. In Alarm Data, choose on which category of equipment, part and data type you want to set the alarm.
5. In Alarm Conditions, choose the conditions on which the alarm is triggered.
6. In Alarm Notifications, choose if you want to display a visual notification in the status bar (like in the big Scala picture) and a sound.
7. For example, with these parameters you are alerted when the catch is full:
Setting an AlarmYou can be alerted by an alarm when data received have a given value.
(blinking) data are receivedCommunication with the receiver has been lost for a few sec. There is a connection problem.There is no communication with the receiver.
Renaming a page1. Right-click the page tab and select
Rename.2. Write a name.3. Press Enter.
Changing the display of page elementsYou can change the title of the elements or the element itself (dial, gauge or history plot).1. To change the title, right-click the title
and choose:
2. To change the display of a dial, gauge or plot, right-click the element and choose among the different options.
• Font size• Font color: it
changes only the color of numerical data, except for history plots where it changes the line color.
• Custom title to change the default title.
On the top of the echogram, you can see:• Name of the sensor, followed by a
number corresponding to its location on the trawl (see Scala user guide for more details).
• Battery level of the sensor• Target Strength if using V3 Explorer
sensors (helps you differentiate species and sizes of fish).
3. Click data, for example Pitch, and hold your click. After 3 sec. a rectangle with data appears. Drag it to the middle of the screen, above grey stripped areas. The area becomes yellow when you can place data.
4. Stop clicking to drop data in this area.
5. From the window that appears, choose how you want to display data: dial, history plot, text...
6. Drag the lines around data to resize them.