3 | Table of ContentsContents

Waterproof Lollipop Min/Max Thermometer, #11050 . . . . . . . . . . . . . . . . . . . . 4

FlashCheck Jumbo Display Digital Probe Thermometer, #11061 . . . . . . . . . . . . . . . 5

FlashCheck Jumbo Display Digital Probe Thermometer, #11062 . . . . . . . . . . . . . . . 6

FlashCheck Jumbo Display Auto!Cal Needle Probe Thermometer, #11063 . . . . . . . . . . . 7

Min/Max Alarm Digital Thermometer, #12207 . . . . . . . . . . . . . . . . . . . . . . . 8

Waterproof Dishwasher Thermometer Kit, #12214 . . . . . . . . . . . . . . . . . . . . . 9

Analog Brix Meter - Sugar Refractometer, #12220 . . . . . . . . . . . . . . . . . . . . . 10

Digital Brix Meter - Sugar Refractometer, #12223 . . . . . . . . . . . . . . . . . . . . . . 11

Jumbo Display Thermo!Hygrometer, #13307 . . . . . . . . . . . . . . . . . . . . . . . . 14

Flash Check Folding Probe Electronic Thermometer, #15000 . . . . . . . . . . . . . . . . . 20

ThermoTrace Waterproof Infrared Thermometer, #15006 . . . . . . . . . . . . . . . . . . 21

ThermoTrace Waterproof Infrared Thermometer, #15006-40 . . . . . . . . . . . . . . . . . 22

ThermoTrace Infrared Laser Thermometer, #15036 . . . . . . . . . . . . . . . . . . . . . 23

ThermoTrace Combo Infrared Thermometer, #15038/#15013 . . . . . . . . . . . . . . . . 24

ThermoTrace Infrared Gun Thermometer, #15041 . . . . . . . . . . . . . . . . . . . . . . 25

On-Line Infrared Thermometer, #15201 - #15204 . . . . . . . . . . . . . . . . . . . . . . 26

In-Transit Temperature Recorder, #16000 - #16403 . . . . . . . . . . . . . . . . . . . . . 27

HVAC/R Disposable Temperature Recorder, #17100-17101 . . . . . . . . . . . . . . . . . . 28

Digital Display Environmental Temperature Recorder, #18020 - #18031 . . . . . . . . . . . . 29

FlashLink Wireless Repeater, #20121 . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

FlashLink Wireless Ambient Temperature Sensor, #20124 . . . . . . . . . . . . . . . . . . 31

FlashLink Wireless Ultra-Low Cryogenic Sensor, #20125 . . . . . . . . . . . . . . . . . . . 32

FlashLink Wireless Temperature & Humidity Sensor, #20126 . . . . . . . . . . . . . . . . . 33

FlashLink Wireless External Sharp Temperature Probe, #20129 . . . . . . . . . . . . . . . . 34

FlashLink 900 MHz Wireless Receiver, #20132 . . . . . . . . . . . . . . . . . . . . . . . 35

FlashLink Wireless Dry-Ice Sensor with External Thermistor Probe, #20151 . . . . . . . . . . 36

FlashLink 418 MHz Wireless Ethernet Receiver, #20156 . . . . . . . . . . . . . . . . . . . 37

FlashLink 900 MHz Wireless Ethernet Receiver, #20158 . . . . . . . . . . . . . . . . . . . 38

FlashLink 2.4 GHz Wireless Receiver, #20170 . . . . . . . . . . . . . . . . . . . . . . . . 39

FlashLink 2.4 GHz Wireless Repeater, #20171 . . . . . . . . . . . . . . . . . . . . . . . . 40

FlashLink 2.4 GHz Wireless RF Logger - Temperature, #20172 . . . . . . . . . . . . . . . . 41

FlashLink 2.4 GHz Wireless RF Logger - Temperature and Humidity, #20173 . . . . . . . . . . 42

FlashLink 2.4 GHz Wireless RF Bluetooth Range Extender, #20188 . . . . . . . . . . . . . . 43

FlashLink 2.4 GHz Wireless RF Logger - External RTD Probe, #20175 . . . . . . . . . . . . . 44

FlashLink Electronic Data Logger, #20202 . . . . . . . . . . . . . . . . . . . . . . . . . 45

FlashLink Electronic Data Logger, #20204 . . . . . . . . . . . . . . . . . . . . . . . . . 46

Page 4: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

DELTATRAK PRODUCT BINDER | 2FlashLink Electronic Data Logger, #20205 . . . . . . . . . . . . . . . . . . . . . . . . . 47

FlashLink Electronic Data Logger, #20207 . . . . . . . . . . . . . . . . . . . . . . . . . 48

FlashLink Electronic Data Logger, #20209 . . . . . . . . . . . . . . . . . . . . . . . . . 49

FlashLink Pro Display Data Logger, #20261. . . . . . . . . . . . . . . . . . . . . . . . . 50

FlashLink Pro Display Data Logger, #20268. . . . . . . . . . . . . . . . . . . . . . . . . 51

T1 Two-Channel Temperature Data Logger, #20500 . . . . . . . . . . . . . . . . . . . . . 52

T2 Four-Channel Temperature Data Logger, #20501. . . . . . . . . . . . . . . . . . . . . 53

TE3 Four-Channel Temperature Data Logger, #20502 . . . . . . . . . . . . . . . . . . . . 54

PT3 Three-Channel Pulse/Temperature Data Logger, #20503. . . . . . . . . . . . . . . . . 55

PTH4 Five-Channel Pressure/Temperature/Humidity Data Logger, #20504 . . . . . . . . . . 56

TC6 Seven-Channel Thermocouple Signal Data Logger, #20506 . . . . . . . . . . . . . . . 57

PS7 Eight-Channel Process Signal Data Logger, #20507 . . . . . . . . . . . . . . . . . . . 58

TC8 Eight-Channel Temperature Logger, #20508 . . . . . . . . . . . . . . . . . . . . . . 59

IC-200 Multi-Logger Interface Cable, #20525. . . . . . . . . . . . . . . . . . . . . . . . 60

High Temp Stainless Steel Data Logger, #20615 . . . . . . . . . . . . . . . . . . . . . . 61

High Temp Stainless Steel Data Logger Thermal Shield, #20623 . . . . . . . . . . . . . . . 62

High Temp Stainless Steel Data Logger, #20616 . . . . . . . . . . . . . . . . . . . . . . 63

Ultra Low Temperature Data Logger, #20621 . . . . . . . . . . . . . . . . . . . . . . . . 64

FlashLink CT-80 Data Logger, #20734 - #20737 . . . . . . . . . . . . . . . . . . . . . . . 65

FlashLink VU In-Transit Data Logger, #20741 - #20748 . . . . . . . . . . . . . . . . . . . 66

FlashLink USB Reusable Data Logger, #20901 . . . . . . . . . . . . . . . . . . . . . . . 67

FlashLink USB Reusable Data Logger with External Probe, #20902-20903 . . . . . . . . . . . 68

FlashLink USB In-Transit Data Logger, #20910-20917 . . . . . . . . . . . . . . . . . . . . 69

FlashLink USB In-Transit Tanker Logger, #20920-20921 . . . . . . . . . . . . . . . . . . . 70

Analog Salt Meter - Salinity Refractometer, #24240. . . . . . . . . . . . . . . . . . . . . 71

Hand Held pH Meter, #24300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

Pocket ISFET pH Meter, #24004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

Digital Thermocouple Thermometer Kit (K Type Probes), #25002 - #25040 . . . . . . . . . . 74

Digital Thermocouple Thermometer Kit (K Type Probes), #25002 - #25040 . . . . . . . . . . 75

FlashCheck Ruggy Thermocouple Thermometer Kit, #25054 - #25056. . . . . . . . . . . . . 76

FlashCheck Ruggy Thermocouple Thermometer Kit, #25054 - #25056. . . . . . . . . . . . . 77

Heat/Cool Digital Cooking Thermometer, #26003 . . . . . . . . . . . . . . . . . . . . . . 78

Pocket Dial Thermometer, #29001/#29007/#29009 . . . . . . . . . . . . . . . . . . . . . 79

Pocket Dial Thermometer, #29002/#29003. . . . . . . . . . . . . . . . . . . . . . . . . 80

Freezer/Refrigerator Thermometer, #29004 . . . . . . . . . . . . . . . . . . . . . . . . 81

Oven Thermometer, #29005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Freezer/Refrigerator Thermometer, #29006 . . . . . . . . . . . . . . . . . . . . . . . . 83

Page 5: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

DELTATRAK PRODUCT BINDER | 3Grill Thermometer, #29010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

FlashLink Mini Intransit Data Logger, #30013-30016 . . . . . . . . . . . . . . . . . . . . 85

Kitchen Timer, Count Down/ Up, #50007 . . . . . . . . . . . . . . . . . . . . . . . . . . 86

Alcohol Wipes, #50009. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

pH Plastic Indicator Strips, #50012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88

Quat Ammonium Test Papers, #50013 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

Chlorine Test Papers, #50014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

FlashCheck Bacteria Enzyme Detection Kit - Real-time Surface Assay, #50025-50026 . . . . . . 91

FlashCheck Bacteria Enzyme Detection Kit - Real-time Food Surface Assay, #50027 . . . . . . 92

FluoreCheck Bacteria Enzyme Detection - FluoreCheck Real-time Fluorometer, #50028-50029 93

FluoreCheck Bacteria Enzyme Detection Kits - Real-Time Assay, #50031-50037 . . . . . . . . 94

High Temperature Thermolabels, page 1, #50109 - #50809 . . . . . . . . . . . . . . . . . 95

High Temperature Thermolabels, page 2, #50109 - #50809 . . . . . . . . . . . . . . . . . 96

Coldmark Thermolabels, page 1, #51001 - #51002 . . . . . . . . . . . . . . . . . . . . . 97

Coldmark Thermolabels, page 2, #51001 - #51002 . . . . . . . . . . . . . . . . . . . . . 98

WarmMark Thermolabels. page 1, #51013 - #51035 . . . . . . . . . . . . . . . . . . . . 99

WarmMark Thermolabels, page 2, #51013 - #51035 . . . . . . . . . . . . . . . . . . . 100

Tempdot Time-Temperature Labels, Model #51030 - #51032 . . . . . . . . . . . . . . . 101

FreezeCheck Thermolabels, #54000 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

TempDot High Temperature Thermal Label, #54114/#53146 . . . . . . . . . . . . . . . . 103

Air Repair Ethylene Absorbers, #19007 - 19011. . . . . . . . . . . . . . . . . . . . . . 104

Air Repair - Application Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

Air Repair - Application Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

PrimePro EAP, #19030 - #19032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

Page 6: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

4

Waterproof Lollipop Min/Max Thermometer, #11050

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

SS0008_11C1

Waterproof Lollipop Min/Max Thermometer

°C/°F selectableMin/Max reading memoryCan be auto calibrated, NSF Certifi edSee-through probe cover with pocket clip on backWaterproof housing - completely submersibleContinuous min/max temperature recording until thermometer shuts off or resetsSmall-diameter probe ideal for measuring temperature of "thin mass" food such as meat patties and chicken/fi sh fi llets (FDA Food Code 4-302.12 (B))

Applications:Use to measure temperature of food that is being cooked, cooled or held. Ideal for use in commercial dishwashers.

Model 11050

Measurement Range -40°F to 311°F (-40°C to 155°C)Accuracy ±1°C (±1.8°F) from -31°F to 212°F(-35°C to 100°C);

±1.5°C (±2.7°F) from 212°F to 266°F(100°C to 130°C); ±2.0°C (±3.6°F) from 266°F to 311°F(130°C to 155°C)

Sensor ThermistorTemperature Resolution 0.1°F (0.1°C)Display Reading Update 1 secondDisplay Window Size 0.77 in W x 0.37 in H (19.5 mm W x 9.5 mm H)Calibration Auto calibration featureBattery LR44 button (A76)Body Casing Polycarbonate and ABS plasticProbe Dimensions Stainless steel, 0.14 in. (Dia.) x 4.13 in. (L) (3.56 mm x 105

mm)Weight 1.3 oz (37.6g)Waterproof Rating IP67Certification CE Mark, NSF

NSF Certified

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 7: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

5

FlashCheck Jumbo Display Digital Probe Thermometer, #11061

FlashCheck®

Measurement Range -40°F to 311°F (-40°C to 155°C)

Accuracy 1°F from -4°F to 113°F (1.8°F otherwise)0.5°C from -20°C to 45°C (1°C otherwise)

Response Time Less than 6 seconds 32°F to 77°F (0°C to 25°C)

Resolution 0.1°(F or C)

Display Size/Update 1.5” x 0.5” (38mm x 12.7mm)/Every 2 Seconds

Waterproof Rating IP56

Probe Length and Tip Diameter

Stainless steel probe, length 3.9 +/- 0.004 in. (99 +/- 0.1mm); Reduced probe tip 0.1 in (2.6mm) dia.

Body ABS plastic

Factory Calibration NIST traceable calibration certified

Compliance Certificate Manufacturers certificate of compliance available from DeltaTRAK, NIST Traceable, CE

Battery 1.5V button

Jumbo Display Auto-Cal Digital Probe Thermometer

10J1

Model 11061

This unique, next-generation, Digital Pocket Probe Thermometer is engineered to set the industry standard for accuracy, durability and readability. It is designed and constructed under exacting standards to meet and exceed specifications required for commercial and professional uses.

Indicates °F or °C. Flashes in display “HOLD” mode.

PATENT NO. 5,709,476

Rotating pocket Clip (backside)

Probe protection cap

One piece ABS unibody and O-Ring sealed construction for superior strength and durability.

Smooth membrane surface and Touch-Pad™

efficiently seal against water, dirt, grease, and other intrusions.

Magnet (backside)

5,801,968

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

New "Auto-Calibration" feature

Reduced tip probe provides less than six (6) second response time

Probe cover with a magnet designed to attach thermometer to a vent

Sealed unibody construction and RoHS-compliant

IP56 waterproof and grease resistant

Velcro strap included to secure thermometer to refrigerant pipes

High visibility yellow casing

Page 8: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

6

FlashCheck Jumbo Display Digital Probe Thermometer, #11062

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FlashCheck®

Temperature Range -40°F to 302°F (-40°C to 150°C)

Accuracy ± 1.0°F (20°F to 194°F) ±0.5°C (-7°C to 90°C) Otherwise ±1.8°F (±1°C)

Display Resolution 0.1°F (0.1°C)

Environmental Operating Range 14°F to 140°F (-10°C to 60°C)

Waterproof Rating IP56

Display Size/Update 1.5 in(W) x 0.5 in (H) (38mm x 12.8mm)/ Every 2 seconds

Probe Length and Tip Diameter 3.9 ± 0.004 in(99 ± 0.1mm), tip diameter: 0.1 in (2.3mm)

Body/Dimensions Polycarbonate and ABS plastics/6.98 in (177.3mm) long

Battery (Type / Life) 1.5 volt size LR44 button alkaline or equivalent / 3,000 hours typical usage

Factory Calibration NIST traceable calibration certified

Certification CE Mark, N.I.S.T. traceable by lot

Jumbo Display Auto-Cal Digital Probe Lab Thermometer

11C1

PATENT NO. 5,709,476 5,801,968

One piece ABS unibody and O-Ring sealed construction for superior strength and durability

Indicates °F or °C. Flashes in display “HOLD” mode.

Smooth membrane surface and Touch-Pad™

efficiently seal against water, dirt, and other intrusions.

Rotating pocket Clip (backside)

Model 11062

Magnet (back)

Clear probe protection cap

This unique, next generation, jumbo display digital probe thermometer is engineered to set the industry standard for accuracy and durability.

Ideal for scientific, laboratory and veterinary use!

New "Auto-Calibration" feature

Highly visible dual scale jumbo LCD Display

Small stainless steel round tip probe (0.1 in/2.3mm diameter)

Sealed unibody construction and RoHS-compliant

Water resistant and washable

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 9: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

7FlashCheck Jumbo Display Auto!Cal Needle Probe Thermometer, #11063

FlashCheck®

Measurement Range -40°F to 311°F (-40°C to 155°C)Accuracy 1.0°F (-4°F to 113°F) ±0.5°C (-20°C to 45°C);

otherwise ±1.8°F (±1.0°C)Response Time Less than 5 seconds (0°C to 25°C/32°F to 77°F)Resolution 0.1°(F or C)Display Size/Update 1.5” x 0.5” (38mm x 12.7mm)/Every 2 SecondsWaterproof Rating IP56Probe Length and Tip Diameter Stainless steel probe, length 3.90 +/- 0.004 in.

(99 +/- 0.1mm); 14 Gauge - Needle probe 0.067 in. (1.7mm) dia. Body ABS plasticFactory Calibration NIST traceable calibration certifiedCompliance Certificate Manufacturers certificate of compliance available from DeltaTRAK,

NIST Traceable, NSF, CE Battery 1.5V

Jumbo Display Auto-Cal Needle Probe Thermometer

SS0012_10J1

Model 11063

This unique, next-generation, Needle Probe Thermometer is engineered to set the industry standard for accuracy, durability and readability. It is designed and constructed under exacting standards to meet and exceed specifications required for commercial and professional uses.

Indicates °F or °C. Flashes in display “HOLD” mode.

PATENT NO. 5,709,476

Rotating pocket Clip (backside)

Clear probe protection cap

Needle probe One piece ABS unibody and O-Ring sealed construction for superior strength and durability.

Smooth membrane surface and Touch-PadTMefficiently seal against water, dirt, grease, and other intrusions.

Magnet (backside)

5,801,968

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

NSF Certified

New "Auto-Calibration" featureNeedle probe thermometer provides fastest response timeSmall-diameter needle probe ideal for measuring temperature of “thin mass” food such as meat patties, chicken, and fish fillets per FDA Food Code 4-302.12(B)Sealed unibody construction and RoHS-compliantIP56 waterproof & grease resistant

Page 10: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

8

Min/Max Alarm Digital Thermometer, #12207

Min/Max Alarm

Temperature Range Internal Sensor: 14°F to 122°F (-10°C to 50°C) External Sensor: -58°F to 158°F (-50°C to 70°C)

Accuracy ±1.8°F (±1.0°C)Resolution 0.1°F (0.1°C)Display Reading Update 10 secondsSensor ThermistorExternal Sensor Cable Length 10 ft (3m)Display Window Size 1.9 in. (W) x .8 in. (H) (48 mm x 21 mm)Product Size 2.9 in. (W) x 2 in. (H) x 6 in. (D) (73 mm x 52 mm x 15 mm)Weight 2.5 oz. (70 g)Body Casing Polycarbonate and ABS plasticProbe Stainless steel probe, .875 in. (L) (17.8 mm)Battery (included) 1.5 volt AAA/ UM4 or equivalentCertification / Calibration CE mark, N.I.S.T. traceable by lot

Digital Thermometer

SS0013_10J1

Model 12207

* Extreme temperatures within the display range cannot be verified for accuracy.DeltaTRAK manufactures products under an ISO 9000 registered quality management system

High/low temperature alarm settingInternal/External sensor switchable Display backlight°C / °F selectableMin/Max memory for internal or external sensor - lowest & highest reading stored for instant recall.Memory function holds up to 99 points of temperature data

Page 11: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

9

Waterproof Dishwasher Thermometer Kit, #12214

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

NSF certifi ed thermometer

°C/°F selectable

Min/Max reading memory

Can be auto calibrated

IP67 waterproof housing

Waterproof plastic protective heat shield with velcro strap

Use to comply with FDA Food Code 4-703.11 (B)

Waterproof DishwasherThermometer Kit

Model 12214Mod

Applications:Ideal for use in commercial dishwashers.

Temperature Range -40°F to 311°F (-40°C to 155°C)Accuracy ±1°C (±1.8°F) from -31°F to 212°F(-35°C to 100°C);

±1.5°C (±2.7°F) from 212°F to 266°F(100°C to 130°C); ±2.0°C (±3.6°F) from 266°F to 311°F(130°C to 155°C)

Sensor Thermistor

Temperature Resolution 0.1°F (0.1°C)Display Reading Update 1 secondDisplay Window Size 0.77 in W x 0.37 in H (19.5 mm W x 9.5 mm H)Calibration Auto calibration featureBattery LR44 button (A76)Body Casing Polycarbonate and ABS plasticProbe Dimensions Stainless steel, 0.14 in. (Dia.) x 4.13 in. (L) (3.56 mm x 105 mm)Weight 1.3 oz (37.6g)Waterproof Rating IP67Certification CE Mark

SS0016_11K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 12: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

10

Analog Brix Meter - Sugar Refractometer, #12220

Scale Brix

Range 0% to 32%

Resolution 0.2%

Accuracy ±0.2%

Automatic Temperature Compensation (ATC) 50°F to 86°F (10°C to 30°C)

Dimension 30mm width x 163 mm length

Weight 147.4 grams

Focus Manual, adjustable

11D3

Hand-held, analog meter

Light-weight, portable, includes protective carrying case

Measures concentration of sugar and dissolved solids in aqueous solution

Automatic Temperature Compensation (ATC)

Ideal for on-site measurement of juices and other sugar-based liquids

Determine fruit quality during harvest, shipping, receiving, processing, storage

Analog Brix Meter

Model 12220

Sugar Refractometer

Page 13: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

11

Digital Brix Meter - Sugar Refractometer, #12223

Scales Brix Refractive Index

Range 0 - 45% 1.3330 - 1.4098

Divisions 0.1 0.0001

Accuracy ±0.1% ±0.0003

Temperature Measurement Range 32°F to 104°F (0°C to 40°C)

Temperature Accuracy ±1°F (±0.5°C)

Measurement Temperature Resolution 0.1°C

Measurement Response Time ! 3 seconds

Minimum Sample Volume 0.3 ml

Dimensions 135 x 65 x 40 mm

Weight 200g

Power Supply 2 x AAA Batteries

Battery Life " 2000 Readings

Automatic Temperature Compensation 41°F to 104°F (5°C to 40°C)

Automatic Shut Off Yes

11D2

Hand-held, digital meter

Light-weight, portable, includes protective carrying case

Measures concentration of sugar and dissolved solids in aqueous solution

Automatic Temperature Compensation (ATC)

Ideal for on-site measurement of juices and other sugar-based liquids

Determine fruit quality during harvest, shipping, receiving, processing, storage

Digital Brix Meter

Model 12223

Sugar Refractometer

Page 14: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

12

Penetrometer - Fruit Firmness Meter, #12226-12228

Model 12226 12227 12228

Measurement Range 0.2 - 15 Kg/cm2 (!105 Pa) 0.2 - 4 Kg/cm2 (!105 Pa) 1-24 Kg/cm2 (!105 Pa)

0.5 - 12 Kg/cm2 (!105 Pa)

Resolution ±0.1 ±0.2 ±0.1 ±0.2

Precision ±0.5 ±0.5 ±0.3-±0.5

Pressure Diameter 3.5mm 3.5mm 8mm 11mm

Accuracy ±0.1% ±0.022% ±0.1%

Show Mode Analog Analog Analog

Out-size L140mm x W60m x H30mm

Insertion Depth: 10mm 10mm 10mm

Weight 0.3 kg 0.3kg 0.3kg

Application bananas, berries,cherries, grapes

apricots, peaches,plums, citrus, melons, persimmons, tomatoes

avocados, pears, nectarines, kiwi

apples

11D2

Model 12226 Model 12227 Model 12228

Hand-held, analog meter

Light-weight, portable, includes protective carrying case

On-site measurement of fruit firmness indicates maturity or ripeness

Easy to read scale - trailing pointer indicates highest resistance point

Plunger tip marked for accurate penetration depth

Determine fruit quality during harvest, shipping, receiving, processing, storage

PenetrometerFruit Firmness Meter

Page 15: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

13

Certi! ed Alarm Thermometer - Internal and External Sensors #12215

Certified Alarm Thermometer

SS0122_11K3

Internal sensor for ambient air temperature

External sensor with high/low alarm setting

Switchable internal/external temperature display

Minimum/Maximum memory for temperature readings

Jumbo LCD display with back light

Switchable ˚F/˚C scale

Magnetic attachment and fold away stand

Model 12215

Internal and External Sensors

A temperature-buffered sensor enclosed in a bottle of propylene glycol solution ensures accurate measurements that are not impacted by rapid temperature fl uctuations caused by frequent refrigerator or freezer door openings. The propylene glycol solution is GRAS (generally recognized as safe) and mimics temperature readings in a medium similar to common fl uids stored in food and laboratory refrigerators, freezers and cold display cases.

Internal Sensor Range 14˚F to 122˚F (-10˚C to 50˚C)

External Probe Range -58˚F to 158˚F (-50˚C to 70˚C)

Accuracy ±1.8˚F (±1.0˚C)

Sampling Rate 10 seconds

Display Resolution 0.1˚

Display Size 1.8in W x 0.87in H (46mm W x 22mm H)

Instrument Size 3.15in W x 2.05in H x 0.67in D (80mm W x 52mm H x 17mm D)

External Probe Type/Size Stainless Steel, 0.43in L x 0.2in Dia (11mm L x 5mm Dia)

External Sensor Bottle Polystyrene with PE cap, 1.6in L x 0.79in Dia (41mm L x 20mm Dia)

External Sensor Buffer Propylene glycol (GRAS classified – Generally Recognized As Safe)

External Sensor Cable 9.84ft x 0.08in Dia (3 meters x 2mm Dia)

Battery CR2032, 3 volt x 1

Certification CE mark, NIST traceable, WEEE

Page 16: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

14

Jumbo Display Thermo!Hygrometer, #13307

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Jumbo Display

Temperature Range Internal: 32°F to 122°F (0°C to 50°C) External Probe: -58°F to 158°F (-50°C to 70°C)

Humidity Range Internal: 20% to 90% Temperature Accuracy(Int. & Ext.) ±1.8°F (1°C) from -40°F to 158°F (-40°C to 70°C)

Humidity Accuracy(Internal) ±3% R.H. from 35% to 85% R.H. at 77°F (25°C)External Temperature Sensor Cable length: 10 ft/3meters; probe: 30cm (L) x 0.5cm (dia.) tipResolution R.H.1%, temperature 0.1°F /0.1°CDisplay Reading Update 10 SecondsDisplay Window Size 3.11 in. (W) x 2.79 in. (H) (79 mm x 66 mm)Character Height within Display 1.06 in. (17mm)Product Size 3.85 in. (W) x 4.33 in. (H) x .82 in. (D) (98 mm x 110 mm x 21 mm)Weight 2.4 oz. (68 g)Body Casing Polycarbonate and ABS plasticSensor Type Temperature: thermistor

Humidity: electronic capacitance polymer film Battery 1.5 volt AAAFreeze Alarm Setting If set, alarm will sound when external temperature is < 32°F (0°C) Waterproof Rating IP67 (Probe Only)Certification/ Calibration CE mark/ N.I.S.T. traceable

Thermo-Hygrometer

Model 13307

An indispensable QC and test instrument when constant temperature and humidity monitoring is required

°C/°F selectable

Freeze alert

Jumbo display for temperature and humidity

Internal/ external temperature sensors

Min/Max memory - lowest and highest readings stored for instant recall

SS0019_12A1

Internal humidity sensor

Page 17: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

15

Pocket-Type Thermo Hygrometer, #13308P R O D U C T S P E C I F I C AT I O N S

800-962-6776 www.deltatrak.comP.O. Box 398 Pleasanton CA 94566 (925) 249-2250 Fax (925) 249-2251

Pocket-TypeThermo-Hygrometer

Model 13308

°C/°F selectable

Dual display for humidity & temperature

Large and clear display

Fast reading update

Maximum & minimum reading memory

Pen shape design with a pocket clip attached to back side

SPECIFICATIONS (Display accuracy between the measurement range below ONLY)

Humidity Temperature

Measurement Range20-90% RH in 15-50°C/59-122°F range

0-50°C/32-122°F25-90% RH in 5-50°C/41-122°F range

30-90% RH in 0-50°C/32-122°F range

Display Accuracy ±3% (in 30-90% range only) ±1°C/±2°F

Display Resolution 1% 1°C/2°F

Display Reading Update 5 seconds

Battery 1.5 volt, type AAA or equivalent x1 piece

Display Size 52mm(W) x 13mm(H)/2.05 in. (W)x 0.51 in. (H)

Product Size 138mm (W) x 23mm(H) x20mm(D)/5.43 in.(W) x 0.91 in.(H) x 0.79 in.(D)

Product Weight 35.9g/1.27 oz

10J1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 18: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

16

Electronic Circular Chart Temperature Recorder, #14010 - #14012

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Electronic Circular Chart

Temperature Range Selectable -40°F to 30°F / -20°F to 50°F / 50°F to 120°F -40°C to 0°C / -30°C to 10°C / 10°C to 50°CChart Speed Selectable 6 hours, 24 hours, 7 days, 31 daysChart Speed Accuracy ±1%Chart Diameter 6 inches (152.4mm)Temperature Display 3 digit LED 0.5 inches highTemperature Accuracy ±2°F (±1°C)Temperature Sensor Stainless steel probe 2 7/8"L x ¼"D solid state integrated circuit, on 15’ ft. cord Recording Pen Ink typePower Supply 120 VAC, 50/60 Hz., (220/240 VAC, 50 Hz. optional)Battery Backup Holder for 8 alkaline AA cells (batteries not included)Battery Life 48 hoursOperating Temperature 32°F to 120°F (0°C to 49°C)Relative Humidity 96% maximumDimensions 9 in x 6.875 in x 2.33 in (228mm x 174mm x 59mm)Weight 1 lbs 12 oz. (0.7 kg.)

Back-up batteries allow continuous function (up to 48 hrs) during power failures

Stainless steel probe allows you to measure the temperature of air, gas, liquids, powders, and semi-solids

SS0021_11L1

Model 14010(°C) 220v

Select single or continuous chart rotation

Temperature Recorder

Model 14012(°F) 110v

Model 14011(°C) 110v

Page 19: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

17

Electronic Circular Chart Temperature Recorder Replacement Charts and Accessories, #14597 - 14623

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

SS0021_11L1

ChartsTEMPERATURE

RANGESCHART SPEEDS

12 HOURS 24 HOURS 7 DAYS 31 DAYS-20 to +120°F 14600 14601 14602 14603-20 to +50°F 14604 14605 14606 14607+40 to +110°F 14608 14609 14610 14611-30 to +50°C 14612 14613 14614 14615-30 to +10°C 14616 14617 14618 14619+5 to +45°C 14620 14621 14622 14623

*NOTE: For 1.5 Hour, 3 Hour and 6 Hour readings, use the 12 Hour charts.

Recorder Accessories14597 Probe14598 Blue Pen14599 Red Pen

Page 20: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

18

Chart Recorder with Temperature/Humidity/Dew Point Sensor, page1, #14013 - #14014

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Chart Recorder With Temperature / Humidity / Dew Point Sensor

Model 14013115V Recorder

Model 14014220V Recorder

Easy-to-read LCD display shows temperature and humidity

Full function alarm

48-hour battery backup in case of power failure

Operating Ambient Temperature Range +32°F to +120°F (0 to +50°C)

Storage Temperature 0°F to +120°F (-18°C to +50°C)

Primary Power Model 14013 - 115VAC, 50/60 Hz. Plug-in Adapter Model 14014 - 220-240VAC, 50 Hz.

Optional Backup Power 8 AA alkaline batteries (Approx. 48 Hrs.)

Temperature Accuracy +/- 2°F (+/- 1°C)

Relative Humidity Range 10-90%

Relative Humidity Accuracy +/- 3% from 20% to 80% @ 77.0°F (25°C)

Dew Point Range +32°F to +130°F (0°C to +50°C)

Sensor Combined Temperature/Humidity with 6’ cable (extended cable length is available)

Chart 6” Circular chart

Chart Rotation Speeds 31 Days, 7 Days, 24 Hours, 12 Hours, 6 Hours, 3 Hours or 1.5 Hours

Chart Rotation Mode User Selectable — Single turn or continuous

Chart Speed Accuracy +/- 1 %

Display Alphanumeric backlit LCD, 16 Characters, 2 Lines

Temperature Alarm Range -20°F to +120°F (-30°C to +50°C)

Alarm Delay Range User Selectable: No Delay, 10 Min., 30 Min., 1 Hr. or 2 Hr.

Remote Alarm Connection Normally open contacts 48V AC/ DC, 0.1 Amp., dry contacts

Mounting Vertical or horizontal; Free standing or wall mounted

Dimensions 9.25” x 7.25” x 2.75”

Weight 2.5 lb.

Power Consumption 3.5 Watts maximum

10J1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 21: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

19

Chart Recorder with Temperature/Humidity/Dew Point Sensor, page2, #14013 - #14014

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Chart Recorder With Temperature / Humidity / Dew Point Sensor

10J1

ChartsTEMPERATURE

RANGESCHART SPEEDS

12 HOURS 24 HOURS 7 DAYS 31 DAYS-20 to +120°F 14600 14601 14602 14603-20 to +50°F 14604 14605 14606 14607+40 to +110°F 14608 14609 14610 14611-30 to +50°C 14612 14613 14614 14615-30 to +10°C 14616 14617 14618 14619+5 to +45°C 14620 14621 14622 14623

*NOTE: For 1.5 Hour, 3 Hour and 6 Hour readings, use the 12 Hour charts.

Recorder Accessories14597 Probe14598 Blue Pen14599 Red Pen

Page 22: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

20

Flash Check Folding Probe Electronic Thermometer, #15000

Check min/max dishwasher temperature

Reduced probe tip .09" (2.3mm)

Completely waterproof

6 second response time

Rubber molded case can withstand 6' drop

Precision accuracy, can be field calibrated

FlashCheck®

Temperature Range -40°F to 293°F (-40°C to 145°C)Accuracy 1.0°F from ±32°F + 185°F

(±0.5°C from 0°C to +85°C)Display Resolution 0.1°F (0.1°C)Display Update 2.7 secondsWater Resistant Rating IP67, NEMA 6Unit Weight 4.5 ozProbe Stainless steel, 4.4" (111mm)Tapered Tip .75" (19.5mm)Body Polycarbonate & ABS with silicon overmoldCalibration Factory calibrated to NIST traceable standards. Post sale

calibration and certifacates available from DeltaTRAK.Response Time Updates every 6 seconds.

Folding Probe Electronic Thermometer

SS0023_10J4DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Model 15000

Page 23: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

21

ThermoTrace Waterproof Infrared Thermometer, #15006

Instant non-contact surface temperature measurement.

Useful with moving products or for hard to reach places.

Completely waterproof (IP67 compliant)

Two measuring modes: normal and continuous

Alarm settings for high and low temperature limits

Memory function holds up to 99 points of temperature data

ThermoTrace®

Field of View D:S=15:1 At D=1 meter (39.4"); S=66.7mm (2.6")Temperature Range 32°F to 932°F (0°C to 500°C)Display Range* 14°F to 1202°F (-10°C to 650°C)Environmental Operating Range 14°F to 122°F (-10°C to 50°C)Response Time Less than 1 secondAccuracy ±3.6°F (±2°C) from 32°F to 392° (0°C to 200°C) otherwise 1% of

readingEnvironmental Humidty Range 0% to 95% RH (without dew condensation)Display Hold Time 15 secondsScale °F/ °C selectableRepeatability ±2°F (1°C) of reading valueBody Casing ABS plasticBattery 9v alkaline (12 hour life)Emissivity Dark (.95)/Bright (.70) switchableDisplay Resolution 1°F (1°C)Sighting Method Offset laser, Class 2, 670nmWeight 7.05oz. (200g) including batterySize 6.3 in. (L) x 1.7 in. (W) x 1.65 in. (D) (15cm x 4cm x 4 cm)

Waterproof Infrared Thermometer

Model 15006

SS0025_11J1

* Extreme temperatures within the display range cannot be verified for accuracy

Page 24: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

22

ThermoTrace Waterproof Infrared Thermometer, #15006-40

Thermo Trace®

Field of View D:S=15:1 At D=1 meter(39.4”); S=66.7mm(2.6”); minimum spot size = 12.7mm (0.5 in.)

Temperature Measurement Range -22°F to 392°F (-30°C to 200°C)

Display Range* -40°F to 428°F (-40°C to 220°C)

Response Time Less than 1 second

Accuracy ±1°F at 75.2°F (±0.5°C at 24°C) 32°F to 212°F (±1°C from 0°C to 100°C)

Environmental Humidity Range 0 to 95% RH (without dew condensation)Display Hold Time 15 secondsScale °F/ °C selectableRepeatability ±2°F (1°C) of reading valueBody Casing ABS plasticBattery 9v alkaline (15 hour life)Emissivity Hot (.95); Cold (.85) switchableDisplay Resolution 0.1°F (0.1°C)Sighting Method Offset laser, Class 2, 670nmWeight 7.05oz. (200g) including battery

Waterproof Infrared Thermometer (-40°C)

Model 15006-40

* Extreme temperatures within the display range cannot be verified for accuracy

Instant non-contact surface temperature measurementQuickly scan numerous food temperaturesCompletely waterproof (IP67 compliant) for sanitation requirementsTwo measuring modes: normal and continuousAlarm settings for high and low temperature limitsMemory function holds up to 99 points of temperature data

11J1

Page 25: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

23

ThermoTrace Infrared Laser Thermometer, #15036

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Thermo Trace®

Highly accurate

Useful with moving objects or for hard to reach places

Instant non-contact surface temperature measurement

Lightweight, sleekand compact

Infrared Laser Thermometer

Model 15036

Field of View 8:1 (85% energy collecting)Measurement Range -4°F to 626°F (-20°C to 330°C)Display Range* -67°F to 662°F (-55°C to 350°C)Operating Range 32°F-122°F (0°C-50°C) Accuracy From -4°F to 32°F(-20°C to 0°C) ± 4°F (2°C); From 32°F to 626°F (-0°C to 330°C)

± 4°F (2°C)or 2% of reading, whichever is greater

Response Time Less than 1 secondDisplay Hold Time 15 secondsDisplay Resolution 0.1°F/0.1°C (switchable)Emissivity Range Factory set at 0.95 - adjustable 0.05 to 1.00 emissivityBattery & Battery Life AAA x 2pcs, 30 to 40 hour, auto power off after 15 secondsSighting Method Non-coaxial laserWeight 108 grams (3.8 oz) including batteriesDimensions 1.02 in. x 1.77 in.x 5.04 in. (26mm x 45mm x 128mm)IP Rating IP54

* Extreme temperatures within the display range cannot be verifi ed for accuracy

Laser sighting

Waterproof

SS0027_12A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 26: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

24

ThermoTrace Combo Infrared Thermometer, #15038/#15013

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

SS0116_11K1

Item Infrared Thermometer TCT Probe Thermometer

Measurement Range -27°F to 428°F (-33°C to 220°C) -27°F to 428°F (-33°C to 220°C)

Operating Range 32°F to 122°F (0°C to 50°C) 32°F to 122°F (0°C to 50°C)

Accuracy -27°F to -4°F: ±4°F (-33°C to -20°C: ±2°C)-4°F to 212°F: ±2°F (-20°C to 100°C: ±1°C)above 212°F(above 100°C) ±2% of reading

below 23°F: ±2°F ( below -5°C: ±1°C)23°F to 149°F: ±1°F (-5°C to 65°C: ±0.5°C)above 149°F (above 65°C) ±1% of reading

Emissivity Range 0.95 default – adjustable 0.1 to 1, step .01 N/A

Field of View 2.5:1 Distance to spot ratio N/A

Display Resolution (-9.9~199.9°C)

0.1°F/0.1°C , otherwise 1°F/1°C

Battery CR 2450 Lithium, 3V; 40 hours continuous use

Auto Shut Off After 15 seconds idle

IP Rating IP 54

Weight 97 grams including battery

Dimensions 19.7 x 45.4 x 165 mm

Holster, Dual Purpose Belt clip for carrying and insulation from thermal shock

2 in 1 Comb

IR Sensor: Instant non-contact surface temperature measurement

TCT Folding Probe: Internal core temperature measurement

Lock Mode for continuous monitoring

Jumbo Dual Display

Auto Power Off

Min/Max Memory

IP 54 Splash Proof

Optional Dual Purpose Holster (P/N 15103)

Model 15038Optional HolsterModel 15103

Thermo Trace®

Combo Infrared/Thermocouple Thermometer

Page 27: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

25

ThermoTrace Infrared Gun Thermometer, #15041ThermoTrace Infrared Gun Thermometer, #15041504150450455041141414441111141411144144

Page 28: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

26

On-Line Infrared Thermometer, #15201 - #15204

Instant non-contact surface temperature measurement.

State-of-the-art infrared technology

Coaxial Laser

Useful with moving products or for hard to reach places

On-Line

Specifications 15201 15202 15203 15204Area Size Ø6 / 200mm Ø30 / 1000mmAnalog Output 4-20mA 1mV/°C 4-20mA 1mV/°CTemperature Range 32°F to 932°F (0°C to 500°C), display -4°F to 968 °F (-20°C to 520°C)Optics/Spectral Response Silicon lens/Thermopile / 8 to 14 mAccuracy ±1% of reading value or ±2°C, ± 1 digit, whichever is largerDisplay Resolution 1°F/ °C selectableOutput Resolution 0.2°F/°CResponse Speed Less than 1 second (100ms/90%)Sighting Method Coaxial laser markerRepeatability ±2°F (±1°C) of reading valueEmissivity 0.10 to 1.20 (0.01/1step)Environmental Humidity 35 to 85% RH (without dew condensation)Ambient Temperature 32°F to 122°F (0°C to 50°C)Waterproof Rating IP65Power Supply DC12 to 24V±10% / MAX 150mAStorage Conditions 14°F to 140°F (-10 to 60°C)Vibration Resistance 3G (20 to 50Hz, according to JIS CO 911)Weight 12.35 oz. (350g)Optional Accessory Air purge collar (order Part No. 15205)

Infrared Thermometer

Model 15201FOV: 6/200mm

Model 15202FOV: 6/200mm

Model 15203FOV: 30/1000mm

Model 15204FOV: 30/1000mm

SS0030_12A2

Page 29: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

27

In-Transit Temperature Recorder, #16000 - #16403

In-Transit

Temperature Range Standard Model: -20°F to 100°F (-29°C to 38°C)High Range Model 32°F to 150°F (0°C to 65°C)Low Range Model -40°F to 80°F (-40°C to 27°C)

Accuracy ±2°F (±1°C) or better

Sensor Bi-metal coil

Chart Pressure sensitive, total length 36 inches (91.4cm),dual scale °F/°C

Drive Solid state quartz motor

Time Keeping Accuracy/Clock Motor Average ±20 seconds a month

Battery AA Alkaline - high range modelsAA Carbon Zinc - standard modelsAA Lithium - low range model

Shelf Life 3 years

Size 5.5 in (L) x 4 in (W) x 2.5 in (H), 13.5 cm (L) x 10 cm (W) x 6.3 cm (H)

Weight 8.6 oz. (244g)

Case Lot Size/Weight 20 recorders per case/ 12lbs. (5.4kg)

Certification/calibration CE mark by T.U.V., traceable to N.I.S.T.

Temperature Recorder

60-Day Model 16400

90-Day Model 16500

10-Day Model 16100

20-Day Model 16200

30-Day Model 16300

30-Day Model 16302

60-Day Model 16402

20-Day Model 16202

10-Day Model 16104

20-Day Model 16203

90-Day Model 16502

05-DayModel 16004

5-Day Model 16000

60-Day Model 16403

STANDARD RANGE

HIGH RANGE

5-Day Model 16002

10-Day Model 16102

LOW RANGE

PATENT NO. 4,990,940

Dual scale °F/°C chart

Bilingual operation instructions

Various models ranging from 5-Day to 90-Day transit periods

Available in three temperature ranges

Patented design guarantees recording trace stops at end of trip

Vented case for superior air circulation and faster temperature response

Serial number on each unit for traceability

10K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 30: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

28

HVAC/R Disposable Temperature Recorder, #17100-17101

10C1

HVAC/R DISPOSABLE

Refrigeration

Heating

Facility maintenance

Equipment diagnosis

Temperature Recorder

Model 17100 5-day

Model 17101 10-day

A/C

Ventilation

See-Thru Window

The low-cost alternative to traditional recorders. Ideal for use where expensive recorders may be damaged or stolen, or when multiple recorders are needed. Factory calibrated and ready for use.

Temperature Range -20°F to 100°F (-29°C to 38°C)

Accuracy ±2°F (1°C) or better

Chart Pressure sensitive, total length 36 inches (91.4cm), dual scale °F/°C

Sensor Bi-metal coil

Drive Solid-state quartz motor

Battery AA alkaline (3-year shelf life)

Size 5.5 in (L) x 4 in (W) x 2.5 in (H), 14 cm (L) x 10 cm (W) x 6.3 cm (H)

Weight 11 oz. (311g)

Case lot / Weight 20 units per carton/ 15lbs.(6.8kg)

Certification/Calibration CE mark by T.U.V., traceable to N.I.S.T.

Page 31: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

29

Digital Display Environmental Temperature Recorder, #18020 - #18031

This next-generation family of reusable environmental temperature recorders offer analog temperature recording along with an accurate digital temperature display feature for instant, easy viewing and permanent record-keeping.

Highly visible LCD display and large window for viewing current and recently chart recorded temperature data Light weight, compact and battery operated, can be wall-mounted, or hung from a loop Wall-mounting bracket, screws and QC chart provided 12 models in °F and °C scales and two temperature ranges for 3-Day, 10-Day, 31-Day and 62-Daytime intervals

Digital Display EnvironmentalTemperature Recorder

Low Temp Range -20°F to 100°F (-28°C to 38°C)High Temp Range 30°F to 150°F (0°C to 65°C)Accuracy Chart and Scale: ±1.8°F (±1.0°C)

LCD: ±1.8°F (-20°C to 165°C), ±1.0°C (-7°C to 74°C)LCD Display/Chart Window 1.5” x 0.5” (3.8cm x 1.3cm)/2” x 2.8” (5cm x 7.1cm)Sensor Bi-metal coil/thermistorChart Pressure-sensitive 36-inch stripDrive Solid-state quartz motorCertification CE mark, RoHS compliant Battery AAA alkaline (3-year shelf life; 1 to 2 years operating life)Weight 1.1 lb (500 grams)Dimensions 4in. x 7in.x 2.25in. (10.2cm x 17.8cm x 5.72cm)Casing Materials High impact ABS

Models 18020-18031

SS0033_10J1DeltaTRAK manufactures data loggers under an ISO 9000 registered quality management system

Page 32: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

30

FlashLink Wireless Repeater, #20121

FlashLink® Wireless

Channel Capacity Hops through 25 channels. Features 7 different hop sequencesEnclosure (Casing) High impact acrylonitrile butadiene styrene (ABS)Frequency Control Direct FMFrequency Range 418 MHz(Rx) and 900MHz(Tx) unlicensed ISM BandAccessories 6.5in (165mm) reverse polarity SMI antenna

9VDC power supplyNetwork Topology Mesh networkingPower Supply 6W 9VDC 300mA 120V power supply with 2.5 mm x 5.0 mm x 9.5 mm

output plugTransmission Range

Indoor: 1300ft. (396 m) (max) (depending on environment)

Receiving Range (from sensor)

Indoor: 600ft. (183 m) (max) (depending on environment)

Size 4.25in (L) 3.25in (W) 1.375in (H) (108 x 83 x 35mm)Transceiver Type Frequency hopping spread spectrum transceiver

Repeater

10J1

Repeats signals from sensors and other repeaters for superior scalabilityReceives readings from all FlashLink Wireless sensors from up to 600 feet awaySends signals either to another repeater or to a receiverUp to 1,300 feet of networking distance from Repeater-to-Repeater or Repeater-to-Receiver

Model 20121

DeltaTRAK manufactures data loggers under an ISO 9000 registered quality management system

Page 33: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

31

FlashLink Wireless Ambient Temperature Sensor, #20124

10J1DeltaTRAK manufactures data loggers under an ISO 9000 registered quality management system

Temperature Measurement Range -40°F to 185°F (-40°C to 85°C)

Temperature Accuracy ±0.9°F (±0.5°C) from 32°F to 185°F (0°C to 85°C) ±1.8°F (±1°C) < 32°F (0°C)

Temperature Resolution 0.1°F/°C

Battery Type/Life 3-Volt Lithium/ (2 to 3 years in live mode)

Data Throughput 9600 or 19200bps

Compliancy FCC Part 15

Enclosure (Casing) High impact acrylonitrile butadiene styrene (ABS)

Frequency Control Direct FM

Frequency Range 418 MHz, unlicensed ISM Band

Unique Identifier 22-character unique ID

Network Topology Point-to-point transparent networking

Operating Temperature -22°F to 185°F (-30°C to 85°C)

Tx (Transmission) Range 600ft (183 m) max.

Size 3.063in (L) 1.938in (W) 0.875in (H) (79 x 50 x 22 mm)

Transmitter Type Internal loop antenna; 15 milliseconds transmission time at random intervals

Transmission Intervals 10 to 17 seconds random

Transport Protocol Various monitoring and addressing modes

Ambient Temperature Sensor

Model 20124

Highly reliable temperature measurements and data transmission

Sends signal up to 600 feet distance to a 418MHz Receiver, or a 900MHz Repeater with 900MHz Receiver

Low power consumption for years of non-stop operation before battery change

Data is recorded and managed with FlashLink Wireless Manager Software

FlashLink® Wireless

Page 34: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

32

FlashLink Wireless Ultra-Low Cryogenic Sensor, #20125

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

Measurement Range -328°F to -238°F (-200°C to -150°C)

Accuracy ±1.0°F (±0.5°C) from -328°F to -238°F (-200°C to -150°C)

Resolution 0.1° (F or C)

Battery Type/Life 3.6 Volt Lithium battery ( 6 to 10 years in live mode)

Data Throughput 9600 or 19200 bps

Compliancy N.I.S.T. traceable, FCC part 15

Enclosure ABS plastic

Frequency Control FM

Frequency Range 418 MHz

Unique Identifier 22-charactor unique ID

Network Topology Point to point transparent networking

Operating Range -40°F to 185°F (-40°C to 85°C)

Transmitting Range 600 feet (183 meters) line of sight depending on environmental conditions

Size 3.063in (L) 1.938in (W) 0.875in (H) (79 x 50 x 22 mm)

Transmitter Type Frequency hopping spread spectrum transmitter

Transmission Interval 10 to 17 seconds random

Transport Protocol Various monitoring and addressing modes

10D1

External stainless steel thermistor

probe with 3" (76.2mm) Tefl on

covered sensor

Low power consumption for years

of non-stop operation before

battery change

Send signal up to 600 feet (183 meters)

distance to a 418 MHz receiver

Data is recorded and managed

with FlashLink Wireless Manager

Software

Model 20125

FlashLink® WirelessUltra-Low Cryogenic Sensor

DeltaTRAK manufactures data loggers under an ISO 9000 registered quality management system

Page 35: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

33

FlashLink Wireless Temperature & Humidity Sensor, #20126

FlashLink® Wireless

10J1DeltaTRAK manufactures data loggers under an ISO 9000 registered quality management system

Temperature Measurement Range -40°F to 158°F (-40°C to 70°C)

Temperature Accuracy ±0.9°F (±0.5°C) from 32°F to 158°F (0°C to 70°C) ±1.8°F (±1°C) < 32°F (0°C)

Temperature Resolution 0.1°F/°C

Humidity Measurement Range 0% to 100% non-condensing

Humidity Measurement Accuracy ±5% from 20% to 80% from 32°F to 158°F (0°C to 70°C)

Battery Type/Life 3.6 volt Lithium/ (2 to 3 years in live mode)

Compliance FCC part 15

Enclosure (Casing) High impact acrylonitrile butadiene styrene (ABS)

Frequency Control Direct FM

Frequency Range 418 MHz, unlicensed ISM Band

Unique Identifier 22-character unique ID

Network Topology Point-to-point transparent networking

Operating Temperature -40°F to 158°F (-40°C to 70°C)

Power Supply Battery powered

Tx (Transmission) Range 600ft (183 m) max.

Size 3.063in (L) 1.938in (W) 0.875in (H) (79 x 50 x 22 mm)

Transmitter Type Internal loop antenna; 15 milliseconds transmission time at random inter-vals

Transmission Intervals 10 to 17 seconds random

Transport Protocol Various monitoring and addressing modes

Temperature & Humidity Sensor

Model 20126

Highly reliable measurements and data transmission

Sends signal up to 600 feet distance to a 418MHz Receiver, or a 900MHz Repeater with 900MHz Receiver

Low power consumption for years of non-stop operation before battery change

Data is recorded and managed with FlashLink Wireless Manager Software

Page 36: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

34

FlashLink Wireless External Sharp Temperature Probe, #20129

10J1DeltaTRAK manufactures data loggers under an ISO 9000 registered quality management system

FlashLink® Wireless External Sharp Temperature Probe

Model 20129With external stainless steel sharp thermistor probe

Low power consumption for years of non-stop operation before battery change

Data is recorded and managed with FlashLink Wireless Manager Software

Sends signal up to 600 ft. distance to a 418MHz Receiver, or a 900MHz Repeater with 900MHz Receiver

Temperature measurement range -40°F to 185°F (-40°C to 85°C)

Temperature Accuracy ±0.9°F (±0.5°C)

Temperature Resolution 0.1°F/°C

Battery Type/ Life 3.6 Volt Lithium (6 to 10 years in live mode)

Compliancy FCC part 15

Enclosure (Casing) High impact acrylonitrile butadiene styrene (ABS)

Frequency Control Direct FM

Frequency Range 418 MHz, unlicensed ISM Band

Unique Identifier 22-character unique ID

Network Topology Point-to-point transparent networking

Operating Temperature -40°F to 185°F (-40°C to 85°C)

Power Supply Battery powered

Probe 5.18in. (132mm) stainless steel thermistor sharp probe on 5 ft. (1.5M pvc cable

Tx (Transmission) Range 600ft (183 m) max.

Size 3.063in (L) 1.938in (W) 0.875in (H) (79 x 50 x 22 mm)

Transmitter Type Internal loop antenna; 15 milliseconds transmission time at random intervals

Transmission Intervals 10 to 17 seconds random

Transport Protocol Various monitoring and addressing modes

Weight 1.5 oz

Page 37: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

35

FlashLink 900 MHz Wireless Receiver, #20132

10J1DeltaTRAK manufactures data loggers under an ISO 9000 registered quality management system

FlashLink® Wireless 900 MHz Receiver

Channel Capacity Hops through 25 channels. Features 7 different hop sequences and 65,000 network identifiers.

Channel Data Rate 10kbData Throughput 19200bpsEnclosure (Casing) High impact acrylonitrile butadiene styrene (ABS)Frequency Control Direct FMRadio Frequency 900 MHz, unlicensed ISM bandAccessories 6.5 in (165mm) reverse polarity SMI antenna, 9V DC power supplyInterface Rejection 70 dB at pager and cellular phone frequenciesNetwork Topology Point-multipoint, point-to-point or multi-drop transparent networkingOutput to PC RS232 (DE9) serial portPower Supply 6W 9V DC 300mA 120V power supply with (2.5mm x 50.mm x

9.5mm) output plugRange Indoor: 1300 ft (from repeater) maximum (depending on

environment)Rx (Reception) Sensitivity -110dBmSerial Data Interface 19200bpsSize 4.125 in (L) 2.625 in (W) 1.125 in (H) (1-5 x 67 x 29mm)Transceiver Type Frequency hopping spread spectrum transceiverTransport Protocol Various monitoring and addressing modes

Receives signals from up to 100 Sensors

900MHz Receiver with RS232 serial output to PC

Up to 1,300 feet of networking distance between the Receiver

and Repeater

Plug-and-play, setup-free design

Data is recorded and managed with FlashLink Wireless

Manager Software

Model 20132

Page 38: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

36

FlashLink Wireless Dry-Ice Sensor with External Thermistor Probe, #20151

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Temperature Measurement Range -112°F to 14°F (-80°C to -10°C)

Temperature Accuracy ±1.0°F (±0.5°C) from -22°F to -112°F or -30°C to -80°C±2.7°F (±1.5°C) from 14°F to -22°F or -10°C to -30°C

Temperature Resolution 0.1°F/°C

Battery Type / Life (1/2) 3.6Vdc Lithium/6 to 10 years in live mode)

Compliance CE Mark, N.I.S.T. traceable and FCC part 15

Enclosure (Casing) High impact Acrylonitrile Butadiene Styrene (ABS) plastic

Frequency Control FM (Frequency Modulation)

Frequency Range 418 MHz or 902 - 928MHz , unlicensed ISM Band

Unique Identifier 22-character unique ID

Network Topology Point-to-point transparent networking

Operating Temperature -40°F to 185°F (-40°C to 85°C)

Probe (Material / Length) Teflon sleeve covered sensor/4ft or 1.2m

Tx (Transmission) Range 600ft (183m) Line-of-Sight

Size 3.063in (L) 1.938in (W) 0.875in (H) (79 x 50 x 22 mm)

Weight 1.5 oz.

Transmitter Type / Timing Frequency hopping spread spectrum/15 milliseconds transmission time at random intervals

Transmission / Logging Intervals 10 to 17 seconds random/Transmit reading every 1 min.

Transport Protocol Various monitoring and addressing modes

FlashLink® Wireless Dry-Ice (-80°C) Sensor with External Thermistor Probe

Model 20151 (418 MHz)

Teflon-coated thermistor

9ft / 2.75m extension cable for easy probe placement

Low power consumption for years of

non-stop operation before battery change

Data is recorded and managed with FlashLink Wireless

Manager Software

Communicate with 418MHz-in/900MHz-out repeater or

418MHz receiver from up to 600 feet away (repeater to

receiver communication distance is scalable)

10J1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 39: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

37

FlashLink 418 MHz Wireless Ethernet Receiver, #20156

FlashLink® Wireless418 MHz Ethernet Receiver

Enclosure (Casing) High impact acrylonitrile butadiene styrene (ABS plastic)

Environmental Operating Range 55°F to 100°F (12°C to 37°C) 0 to 85% R.H. w/o condensation

Frequency Control FM

Frequency Range 418 MHz Unlicensed ISM Band

Identifier 64-bit unique ID

Included Accessories 3.5 in. (89mm) reverse polarity SMI antenna with 2 meter cable

Network Topology Point to point transparent networking

Output to PC Communicates to host via Ethernet (TCP/IP and UDP) Static or Dynamic IP Identification. Ethernet Receiver can send sensor packets to 3 UDP destinations

Power 5VDC 500mA External power supply or Power Over Ethernet (PoE)110 VAC/DC or 220VAC/DC power adapter

Range Indoor: 600 Feet (183 Meters) line of sight max.

Serial Data Baud Rate 19,200bps

Receiver Type 418 MHz Receiver (decodes CRC-16 error encoded radio packets)

Rx (Reception) Sensitivity -110dB

Sensor Monitoring Capacity 100 Sensors (max)

Serial Data Interface Type Communicates to host via Ethernet LAN

Size 4"W x 3"L x 1.4"H (102mm W x 76mm L x 36mm H)

Storage Conditions 40°F to 122°F (4°C to 50°C) 0 to 85% R.H. w/o condensation

Certification CE mark, FCC, CFR Part 15 compliant

10J1

Model 20156

418 MHz receiver communicates to host via ethernet static or dynamic IP Identification

Receives sensor readings from up to 600 feet (183 meters) away

Receives signals from up to 100 sensors

Data recorded and managed with FlashLink Wireless Manager Software

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 40: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

38

FlashLink 900 MHz Wireless Ethernet Receiver, #20158

FlashLink® Wireless900 MHz Ethernet Receiver

Enclosure (Casing) High impact acrylonitrile butadiene styrene (ABS plastic)

Environmental Operating Range 55°F to 100°F (12°C to 37°C) 0 to 85% R.H. w/o condensation

Frequency Control FM

Frequency Range 900 MHz Unlicensed ISM Band

Identifier 64-bit unique ID

Output to PC Communicates to host via Ethernet (TCP/IP and UDP) Static or Dynamic IP Identification. Ethernet Receiver can send sensor packets to 3 UDP destinations

Power 5VDC 500mA External power supply or Power Over Ethernet (PoE)

Range Indoor: 1300 Feet (396 Meters) line of sight max.

Serial Data Baud Rate 19,200bps

Receiver Type 900 MHz Receiver (decodes CRC-16 error encoded radio packets)

Rx (Reception) Sensitivity -110dB

Sensor Monitoring Capacity 100 Sensors (max)

Serial Data Interface Type Communicates to host via Ethernet LAN

Size 4"W x 3"L x 1.4"H (102mm W x 76mm L x 36mm H)

Storage Conditions 40°F to 122°F (4°C to 50°C) 0 to 85% R.H. w/o condensation

Certification CE mark, FCC, CFR Part 15 compliant

10J1

Model 20158

900 MHz receiver communicates to host via Ethernet static or dynamic IP Identification

Receives sensor readings from up to 1300 feet (396 meters) away

Receives signals from up to 100 sensors

Data recorded and managed with FlashLink Wireless Manager Software

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 41: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

39FlashLink 2.4 GHz Wireless Receiver, #20170

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FlashLink® 2.4 GHz Wireless

Operating Temperature Range -20˚C to +50˚C

Frequency Range 2.405 to 2.475 GHz, IEEE 802.15.4 PHY compliant

Transmit +13.0 dBm (including 2.2 dBi gain of the antenna)

Receive -103.0 dBm

Typical Range indoor: 164 feet (50m), outdoor: 328 feet (100m)

Battery Backup Life 5 days

Interface RS232

Backup Battery 3 rechargeable AA nickel metal hybrid

Antenna External omni-directional swivel antenna, SMA connector

Waterproof Rating IP20

Mount 4 hole screw mount

Weight 8.2 oz (232 g)

Color White

Dimension 2.0 x 2.7 x 3.9 inch (50.0 x 68.0 x 100.0 mm)

Power Source External, 6.0 – 12.6 V, 500 mA

Certification CE mark, RoHS

11B1

Network control module, enables all communication between RFID components and back offi ce system

Mesh networking technology optimizes data transfer

Self confi guring and fault-tolerant to ensure quality communication (Real Time Location System)

Easily reprogramable for fi rmware updates

Internal back-up power source

Model 20170

Receiver

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 42: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

40

FlashLink 2.4 GHz Wireless Repeater, #20171

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FlashLink® 2.4 GHz WirelessRepeater

Operating Temperature Range -40˚C to +85˚C

Frequency Range 2.405 to 2.475 GHz, IEEE 802.15.4 PHY compliant

Transmit +13.0 dBm (including 2.2 dBi gain of the antenna)

Receive -103.0 dBm

Typical Range Indoor: 164 feet (50m), Outdoor: 328 feet (100m)

Battery Backup Life 5 days

Backup Battery 3 rechargeable AA nickel metal hybrid batteries

Antenna External omni-directional swivel antenna, SMA connector

Waterproof Rating IP65

Mount 4 hole screw mount

Weight 8.2 oz (232 g)

Color White

Dimension 2.0 x 2.7 x 3.9 inch (50.0 x 68.0 x 100.0 mm)

Power Source External, 6.0 – 12.6 V, 500 mA

Certification CE mark, RoHS, FCC ID

11B1

Wireless data transport module, 3rd generation active RFID

Mesh networking technology optimizes data transfer

Self confi guring and fault-tolerant to ensure quality communication (Real Time Location System)

Remote updating with fi rmware updates

Internal back-up power source

Model 20171

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 43: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

41

FlashLink 2.4 GHz Wireless RF Logger - Temperature, #20172

Wireless temperature monitoring, active RFID sensor/logger User -configurable monitoring parameters includes time intervals, security and alerts IP67 waterproof casing with single mount point Back-up temperature logging ensures continuous monitoring even during communication interruption

Model 20172

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 44: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

42

FlashLink 2.4 GHz Wireless RF Logger - Temperature and Humidity, #20173

Frequency Range 2.405 to 2.475 GHz, IEEE 802.15.4 PHY compliant

Transmit +4.6 dBm (Max. radiated power EIRP)

Receive +85.0 dBm @ 1%PER

Typical Range Outdoor: 164 feet (50m)

Battery Life 3 years

Reporting Rate User configurable, typical 5 minute interval

Temperature Accuracy ± 0.9°F (±0.5˚C) from -13°F to 185°F (-25˚C to 85˚C)

± 1.8°F (±1.0˚C) from -40°F to 185°F (-40˚C to 25˚C)

Humidity Accuracy ±3.5%RH from 20%RH to 80%RH @25°C, ±5%RH at <20%RH or >80%RH

Resolutions Temperature: 0.0625˚C Humidity: 0.0244%RH

Measurement Range Temperature: -40°F to 185°F (-40˚C to 85˚C); Humidity: 10% to 90%RH

Hysteresis Error 1%

Long Term Drift 0.5%

Response Time 30 seconds

Battery 2 AAA lithium batteries

Antenna Integrated on PCB, Omni-directional

Mount Single screw

Weight 1.5 oz (44 g)

Color Yellow

Dimension 2.3 x 2.2 x 0.5 inch (59.6 x 56.6 x 14.0 mm)

Certification CE, RoHS, FCC ID, WEEE

Wireless temperature and humidity monitoring, active RFID sensor/logger

Real Time Location System (RTLS)System automatically locates and self registers all components

User-configurable monitoring parameters includes time intervals, security and alerts

Back-up temperature and humidity logging ensures continuous monitoring even during

communication interruption

Red LED indication for active mode

2MB file system allows 4 week data logging sample and user files to be stored

Easy mount with a single screw

Model 20173

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 45: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

43

FlashLink 2.4 GHz Wireless RF Bluetooth Range Extender, #20188

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FlashLink® 2.4 GHz WirelessRF Bluetooth Range Extender

Serial InterfaceData Rates 1200, 2400, 4800, 9600, 19.2k, 38.4k, 57.6k, 115.2k, 230k

Characters 7 or 8 data bitsParity odd, even, or noneStop Bits 1 ro 2Control Signals CTS, RTSFlow Control Hardware (RTS/CTS) or NoneConnector DB9 - DTE (male) or DCE (female)Bluetooth InterfaceProtocol Bluetooth Specification 2.0 (with high EDR data rate!), compatible with 1.1 and 1.2,Connection Modes Master, Slave, Instant Cable ReplacementProfiles Serial Port Profile (SPP)Security FHSS (Frequency Hopping Spread Spectrum)

Radio Class 1 Bluetooth; Up to 330 feet (100 meters)Dimensions, Weight L 2.3" x W 0.8" x H 0.5"; 0.6 oz.without power supplyOperating Temp. -40°C to 70°CPower Supply +5V external power supply (included), 4-11 VDC 50mA max

Reduces bottlenecks and improves the reliability of the entire network

No software or drivers required

Distance range of 330 feet (100 meters)

Status LED's: Transmit/Receive (TX/RX) Data, Power, Connection Status

Model 20188

11E1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 46: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

44

FlashLink 2.4 GHz Wireless RF Logger - External RTD Probe, #20175

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FlashLink® 2.4 GHz WirelessRF Logger - External RTD Probe

Model 20175

SS0050_12A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

M

Wireless temperature monitoring, active RFID logger with external probe

User-confi gurable monitoring parameters includes logging time intervals, security and alerts

IP67 waterproof casing

Continuous monitoring even during communication interruption

External Probe Temperature Range -40°F to 302°F (-40 C to 150 C)Logger Operating Range -40°F to 140°F (-40 C to 60 C)Accuracy ± 1.8°F (±1.0 °C)Resolution 0.1°F (0.1°C)Probe dimensions 2.95 in L x 0.17 in D (75mm L x 4.2mm D), Stainless steel, conical tipCable Teflon, 3.28 ft (3m)Logger Dimension 3.6" length x 2.25" width x 2.0" height (9.1cm x 5.7cm x 5.1cm)Waterproof Rating IP67Weight 6.850 ozBattery, Battery Life 2 AA lithium batteries, 3 YearsFrequency Range 2.4 to 2.475 GHz, IEEE 802.15.4 PHY compliantTransmit -0.4 dBmReceive -92.0 dBmTypical Range Indoor: 82 feet (25m). Outdoor: 164 feet (50m)Data Points 8192Antenna Integrated on PCB, Omni-directionalCertification CE mark, RoHS, FCC ID, WEEE

Page 47: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

45

FlashLink Electronic Data Logger, #20202

FlashLink®

Electronic Data Logger

10K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Model 20202

One internal sensor and one external stainless steel probe 3.5 in (89mm) with 40 in. (1m) cable

Very easy to use and highly accurate

Output charts, graphs, spreadsheets or email your results anywhere in the world

Patent No. 6,088,514

Internal Temp Sensor Range -40°F to 150°F (-40°C to 66°C)

External Temp Sensor Range -40°F to 302°F (-40°C to 150°C)

Temperature Accuracy ±1°F (0.5°C) at 32°F to 150°F (0°C to 66°C) ±2°F (1°C) over entire range

Temperature Resolution 0.1°F/C

Logged Data Capacity 7,918 data points

Data Download Time 5 second typical for 3,800 data points

Programmable Alarm Levels High and Low Levels over entire range

Startup Alarm Delay Skip 1 to 16 points

Operating Alarm Delay 0 to 79 minute delay fi lter

Logging Time Interval Range 3 seconds to 24 hours

Programmable Delayed Start 0 seconds to 256 days

LED Indicators 12-second fl ashing red for alarm; green for active

Battery Type/ Life CR2450 3v lithium/ 1 year

Dimensions/ Enclosure ABS plastic case, 3.25 x 2.25 x .75 in. (8.3 x 5.7 x1.9cm.)

Water Resistance IP56

Shock Resistance Withstands 3-foot drop to hard surface

Certifi cation CE Mark by T.U.V.; Calibration Traceable to N.I.S.T.

Min. System Requirements IBM compatible 486 with 4MB RAM, Windows XP or Vista

Software Requirements FlashLink Program Manager Software #20223

Page 48: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

46

FlashLink Electronic Data Logger, #20204

FlashLink®

Electronic Data Logger

External Temp Sensor Range -40°F to 302°F (-40°C to 150°C)

Temperature Accuracy ±1°F (0.5°C) at 32°F to 150°F (0°Cto 66°C)±2°F (1°C) over the entire range

Temperature Resolution 0.1°F/C

Logged Data Capacity 7,918 data points

Data Download Time 5 second typical for 3,800 data points

Programmable Alarm Levels High and low levels over entire range

Startup Alarm Delay Skip 1 to 16 points

Operating Alarm Delay 0 to 79 minute delay filter

Logging Time Interval Range 3 seconds to 24 hours

Programmable Delayed Start 1 second to 256 days

LED Indicators 12 second flashing red for alarm; green for active

Battery Type/Life CR2450 3v lithium / 1 year

Dimensions / Enclosure ABS plastic case, 3.25" x 2.25" x .75" (8.3 x 5.7 x 1.9 cm)

Water Resistance Withstands immersion up to six inches

Shock Resistance Withstands 3 foot drop to hard surface

Certification CE Mark by T.U.V.; Calibration traceable to N.I.S.T.

Min. System Requirements PC with 4 MB RAM, Windows XP or Vista

Software Requirements FlashLink Program Manager Software

Model 20204

Two sharp-tip external stainless steel temperature probes 3.5 in(89mm) with 40 in.(1m) cable

Very easy to use and highly accurate

Output charts, graphs, spreadsheets or email your results anywhere in the world

Patent No. 6,088,514

10K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 49: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

47

FlashLink Electronic Data Logger, #20205

FlashLink®

Electronic Data Logger

External Temp Sensor Range -112°F to 230°F (-80°C to 110°C)

Temperature Accuracy ±1°F (0.5°C) at 32°F to 150°F (0°C to 66°C)±2°F (1°C) over entire range

Temperature Resolution 0.1°F/C

Logged Data Capacity 7,918 data points

Data Download Time 5 second typical for 3,800 data points

Programmable Alarm Levels High and low levels over entire range

Startup Alarm Delay Skip 1 to 16 points

Operating Alarm Delay 0 to 79 minute delay filter

Logging Time Interval Range 3 seconds to 24 hours

Programmable Delayed Start 0 second to 256 days

LED Indicators 12 second flashing red for alarm; green for active

Battery Type/Life Lithium-Thionyl Chloride/ 3year at 1min interval

Dimensions / Enclosure ABS plastic case, 3.25" x 2.25" x .75" (8.3 x 5.7 x 1.9 cm)

Water Resistance IP56

Shock Resistance Withstands 3 foot drop to hard surface

Certification CE Mark by T.U.V.; Calibration traceable to N.I.S.T.

Min. System Requirements PC with 4 MB RAM, Windows XP or Vista

Software Requirements FlashLink Program Manager Software, #20223

Model 20205

Single low-temp, -112°F (-80°C), external stainless steel blunt tip probe0.5 in(13mm) with 40 in.(1m) cable

Very easy to use and highly accurate

Output charts, graphs, spreadsheets or email your results anywhere in the world

Patent No. 6,088,514

10K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 50: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

48

FlashLink Electronic Data Logger, #20207

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FlashLink®

Electronic Data Logger

Internal Temp Sensor Range -40°F to 150°F (-40°C to 66°C)

Temperature Accuracy ±1°F (0.5°C) at 32°F to 150°F (0°C to 66°C)±2°F (1°C) over entire range

Humidity Accuracy ±5% at 50% RH at 25°C

Operating Humidity Range 1% to 99% RH

Temperature Resolution 0.1°F/C

Logged Data Capacity 10,339 data points

Data Download Time 5 second typical for 3,800 data points

Programmable Alarm Levels High and Low Levels over entire range

Startup Alarm Delay Skip 1 to 16 points

Operating Alarm Delay 0 to 79 minute delay filter

Logging Time Interval Range 3 seconds to 24 hours

Programmable Delayed Start 0 seconds to 256 days

LED Indicators 12-second flashing red for alarm; green for active

Battery Type/ Life CR2450 3v lithium/ 1 year

Dimensions/ Enclosure ABS plastic case, 3.25 x 2.25 x .75 in. (8.3 x 5.7 x1.9 cm.)

Water Resistance IP56

Shock Resistance Withstands3-foot drop to hard surface

Certification CE Mark by T.U.V.; Calibration Traceable to N.I.S.T.

Min. System Requirements IBM compatible 486 with 4MB RAM, Windows XP or Vista

Software Requirements FlashLink Program Manager Software #20223

One internal temperature sensor and one internal

humidity sensor

Very easy to use and highly accurate

Output charts, graphs, spreadsheets or email your results

anywhere in the worldPATENT NO. 6,088,514

Model 20207

10K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 51: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

49

FlashLink Electronic Data Logger, #20209

Single sharp-tip stainless steel external temperature probe 3.5 in(89mm) with 40 in.(1m) cable

Very easy to use and highly accurate

Output charts, graphs, spreadsheets or email your results anywhere in the world

Model 20209

External Temp Sensor Range -40°F to 302°F (-40°C to 150°C)Temperature Accuracy ±1°F (0.5°C) at 32°F to 150°F (0°C to 66°C)

±2°F (1°C) over entire rangeTemperature Resolution 0.1°F/CLogged Data Capacity 7,918 data pointsData Download Time 5 second typical for 3,800 data pointsProgrammable Alarm Levels High and Low Levels over entire rangeStartup Alarm Delay Skip 1 to 16 pointsOperating Alarm Delay 0 to 79 minute delay fi lterLogging Time Interval Range 3 seconds to 24 hoursProgrammable Delayed Start 0 seconds to 256 daysLED Indicators 12-second fl ashing red for alarm; green for activeBattery Type/ Life CR2450 3v lithium/ 1Dimensions/ Enclosure ABS plastic case, 3.25 x 2.25 x .75 in. (8.3 x 5.7 x1.9cm.)Water Resistance IP56Shock Resistance Withstands3-foot drop to hard surfaceCertifi cation CE Mark; Calibration Traceable to N.I.S.T.Min. System Requirements Windows PC with 4MB RAM, Windows XP or VistaSoftware Requirements FlashLink Program Manager Software #20223

PATENT NO. 6,088,514

FlashLink®

Electronic Data Logger

10K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 52: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

50

FlashLink Pro Display Data Logger, #20261

FlashLink® ProDisplay Data Logger

Internal Temp Sensor Range -40°F to 302°F (-40°C to 150°C)

Internal Sensor Accuracy ±1°F (0.5°C) from -4°F to 131°F to 150°F (-20°C to 55°C)±2°F (1°C) over entire range

Data Capacity 16110 data points

Startup Alarm Delay Skip 1 to 16 points

Operating Alarm Delay 0 to 79 minute delay filter

Logging Interval 3 seconds to 24 hours

Delayed Start 1 second to 256 days

Water Resistance Immersion up to 6 inches

Shock Resistance Withstands 3 foot drop to hard surface

Battery Type/Life CR2450/2 year @ 2 min interval @ 75°F

Enclosure ABS plastic case, 3.25 x 2.25 x .75 in. (8.3 x 5.7 x1.9 cm.)

4 Digit LCD Display Operating 14°F to 122°F (-10°C to 50°C) Activate by manual push, 1 minute on, 3 sec. update

Certification CE Mark by T.U.V.

Min. System Requirements PC with 4 MB RAM, Windows XP or Vista

Software Requirements FlashLink Program Manager Software, #20210

Model 20261

LCD and single internal temperature sensor

Alarm light will indicate if recorded temperatures have exceeded pre-selected ranges.

LCD screen allows you to view current temperature.

Software shows data in numeric or graph formats.

Fast download speed - 3800 data points in 5 seconds.

Patent No. 6,088,514

10K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 53: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

51

FlashLink Pro Display Data Logger, #20268

FlashLink® ProDisplay Data Logger

External Temp Sensor Range -40°F to 302°F (-40°C to 150°C)

External Sensor Accuracy ±0.8°F (0.44°C) at -4°F to 185°F (-20°C to 85°C)±1.4°F (0.8°C) over entire range

Data Capacity 16110 data points

Startup Alarm Delay Skip 1 to 16 points

Operating Alarm Delay 0 to 79 minute delay filter

Logging Interval 3 seconds to 24 hours

Delayed Start 1 second to 256 days

Water Resistance Immersion up to 6 inches

Shock Resistance Withstands 3 foot drop to hard surface

Battery Type/Life CR2450/2 year @ 2 min interval @ 75°F

Enclosure ABS plastic case, 3.25 x 2.25 x .75 in. (8.3 x 5.7 x1.9 cm.)

4 Digit LCD Display Operating 14°F to 122°F (-10°C to 50°C) Activate by manual push, 1 minute on, 3 sec. update

Certification CE Mark by T.U.V.

Min. System Requirements PC with 4 MB RAM, Windows XP or Vista

Software Requirements FlashLink Program Manager Software, #20210

Model 20268

LCD and 6ft. (2M) Tefl on cable and external 1” (25mm) blunt probe

Alarm light will indicate if recorded temperatures have exceeded pre-selected ranges.

LCD screen allows you to view current temperature.

Software shows data in numeric or graph formats.

Fast download speed - 3800 data points in 5 seconds.

Patent No. 6,088,514

10K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 54: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

52

T1 Two-Channel Temperature Data Logger, #20500

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Two-Channel: One for the internaltemperature sensor, and one externalchannel for remote Sensing of temperatureresistance

Optimal thermistor temperature probe forremote measurements (ET-016) allows youto have 2 temperature channels loggingsimultaneously.

Accessories: the DeltaTRAK ET series ofThermistor Probes, or any NTC thermistorprobe.

T1Two-Channel Temperature Data Logger

Model 20500

Applications:Food process verifi cation, pharmaceutical storage, transportation of temperature-sensitive goods,equipment run time, HVAC system testing and balancing, etc.

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")Weight 110 g (3.75 oz)

Case Material Noryl® plastic

Battery 3.6 volt Lithium, 1 Amp-HourResolution 8-bit (1 part in 256)Mounting Magnetic backing or locking eyeletClock Accuracy: +/- 2 seconds per daySampling Methods 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)Operating Limits -40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing)PC Requirements Windows PC with at least 256MB RAM, 250MB of free hard drive

space and one free serial or USB portSoftware Requirements TrendReader® 2 [compatible with Windows® XP SP4 (32bit),

Windows Vista SP2 or Windows 7 (32bit or 64bit)]Memory Size 32 K (32,768 readings)Sampling Rates User selectable rates between 8 seconds to once every 5 days

11A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 55: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

53

T2 Four-Channel Temperature Data Logger, #20501

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Four-Channel: One for the internal temperature sensor,and one for the internal RH sensor. The two remainingchannels are reserved for an optional remote EH-020Aprobe (temp & RH probe)

Changes in relative humidity cause the resistance of theelectrically-conducting surface of the water (RH sensor) tovary. The TH2 measures the resistance and converts thereading to a percentage of RH. All RH readings are thentemperature compensated by simultaneously takentemperature readings from the RH sensors companionthermistor. External channgels can also be used to measuretemperature alone (with an ET thermistor probe), or can be measure resistance.

Built-in temperature sensor (2-5 year life span), Plug-in relative humidity sensor

Two extra channels to connect either temperature/RH probe or themistor probe

Accessories: RH-002 replaceable RH sensor, EH-020 remote temperature and relative humidity probe, ET Thermistor temperature probes of any NTC thermistor temperature probe.

T2Four-Channel Temperature Data Logger

Model 20501

Applications:Food Process verifi cation, pharmaceutical storage, transportation of temperature-sensitive goods,equipment run time, HVAC system testing and balancing, etc. An excellent choice for monitoringair quality conditions.

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")Weight 110 g (3.75 oz)

Case Material Noryl® plastic

Battery 3.6 volt Lithium, 1 Amp-HourResolution 8-bit (1 part in 256)Mounting Magnetic backing or locking eyeletClock Accuracy: +/- 2 seconds per daySampling Methods 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)Operating Limits -40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing)PC Requirements Windows PC with at least 256MB RAM, 250MB of free hard drive

space and one free serial or USB portSoftware Requirements TrendReader® 2 [compatible with Windows® XP SP4 (32bit),

Windows Vista SP2 or Windows 7 (32bit or 64bit)]Memory Size 32 K (32,768 readings)Sampling Rates User selectable rates between 8 seconds to once every 5 days

11A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 56: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

54

TE3 Four-Channel Temperature Data Logger, #20502

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Four-Channel: One internal for ambienttemperature and three for AC current(using optional current probes).

Accurate recordings of AC current

Use logger with up to three externalcurrent probes for recording three-phasesystems or related equipment simultaneouslywithout breaking the circuitry

Provides safe current readings by simplyclamping around the power leads.

TE3Four-Channel AC Current and Temperature Data Logger

Model 20502

Applications:Monitoring air conditioning or mechanical equipment; determining electrical consumption, troubleshooting production processes; tracking environmental conditions; checking out energy management strategies; obtaining equipment load profi les; confi rming control sequences; Monitoring 3-phase current, startup or long term load analysis, Demand Side Management (DSM),monitoring mechanical systems, electric motor maintenance scheduling, etc.

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")Weight 110 g (3.75 oz)

Case Material Noryl® plastic

Battery 3.6 volt Lithium, 1 Amp-HourResolution 8-bit (1 part in 256)Mounting Magnetic backing or locking eyeletClock Accuracy: +/- 2 seconds per daySampling Methods 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)Operating Limits -40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing)PC Requirements Windows PC with at least 256MB RAM, 250MB of free hard drive

space and one free serial or USB portSoftware Requirements TrendReader® 2 [compatible with Windows® XP SP4 (32bit),

Windows Vista SP2 or Windows 7 (32bit or 64bit)]Memory Size 32 K (32,768 readings)Sampling Rates User selectable rates between 8 seconds to once every 5 days

11A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 57: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

55

PT3 Three-Channel Pulse/Temperature Data Logger, #20503

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Three-Channel: One internal termperature sensor and twoexternal inputs for pulse signals or dry switch contact closures)

Versatile data loger designed for easy counting and recordingof switch contact closures voltage pulses. It has two inputchannels each with three selectable frequency ranges.

Ranges: 32 pulses/second; 64 pulses/second;128 pulses/second; Miniumum pulse width: 4 milliseconds

Switch Contact Closure Input: Input type: Uncommitted switchor relay contacts.Logic Inputs: Logic type: Active logic signals. Input voltage: Low = 0 to 0.5 volts (DC).Input Impedance: 750 K ohms.

PT3Three-Channel Pulse/Temperature Data Logger

Model 20503

Applications:Monitoring fl ow conditions, energy use, wind speed, RPM, and environmental conditions; Foodprocess verifi cation, pharmaceutical and/or laboratory storage, transportation of temperature-sensitive goods, equipment run time, HVAC system testing and balancing, etc.

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")Weight 110 g (3.75 oz)

Case Material Noryl® plastic

Battery 3.6 volt Lithium, 1 Amp-HourResolution 8-bit (1 part in 256)Mounting Magnetic backing or locking eyeletClock Accuracy: +/- 2 seconds per daySampling Methods 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)Operating Limits -40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing)PC Requirements Windows PC with at least 256MB RAM, 250MB of free hard drive

space and one free serial or USB portSoftware Requirements TrendReader® 2 [compatible with Windows® XP SP4 (32bit),

Windows Vista SP2 or Windows 7 (32bit or 64bit)]Memory Size 32 K (32,768 readings)Sampling Rates User selectable rates between 8 seconds to once every 5 days

11A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 58: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

56

PTH4 Five-Channel Pressure/Temperature/Humidity Data Logger, #20504

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Five-Channel: One internal for ambient temperature, one foroptional internal RH sensor, one for optional pressure sensor,and two for optional remote RH and temperature probe

Designed for easy monitoring and troubleshooting of pneumaticcontrol and low-pressure duct systems. Works with optionalplug-in pressure modules. Also monitors relative humidity aswell as remote temperature and humidity.

Accessories: Pressure modules, RH-002 sensor, Eh-020temperature/RH probe, any ET series Temperature Probes (thermistors).

Ordering Guide: order one or more pressure module. Five different interchangeable ranges available.

PTH4Five-Channel Pressure

Temperature and Relative Humidity Data Logger

Model 20504

Applications:Performance tracking of pneumatic-controlled valves, dampers, thermostats, humidistats, switches, and compressors; checking energy management and control strategies; monitoring sensitive shipments, etc.

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")Weight 110 g (3.75 oz)

Case Material Noryl® plastic

Battery 3.6 volt Lithium, 1 Amp-HourResolution 8-bit (1 part in 256)Mounting Magnetic backing or locking eyeletClock Accuracy: +/- 2 seconds per daySampling Methods 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)Operating Limits -40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing)PC Requirements Windows PC with at least 256MB RAM, 250MB of free hard drive

space and one free serial or USB portSoftware Requirements TrendReader® 2 [compatible with Windows® XP SP4 (32bit),

Windows Vista SP2 or Windows 7 (32bit or 64bit)]Memory Size 32 K (32,768 readings)Sampling Rates User selectable rates between 8 seconds to once every 5 days

11A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 59: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

57

TC6 Seven-Channel Thermocouple Signal Data Logger, #20506

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Seven-Channel: one internal thermistor for cold-junctioncompensation and six external channels for thermcoupleinputs

Accommodates any J, K, S, or T type of thermocouple sensor

On-board thermistor built-in the body of the logger

Available in two models: TC6-N (narrow channel) and theTC6-W (wide channel).

Inputs: thermocouple temperature range and resolutionfor each TC6 channel.

TC6-N: Thermocouple Type, Narrow Channels Range, Narrow Channels ResolutionJ, 0° to 370°F (-20° to 190°C), 2.5°F (1.4°C); K, -10° to 440°F (-25° to 230°C), 3°F (1.7°C);S, 32° to 1750°F (0° to 960°C), 12.6°F (7°C); T, -30° to 390°F (-35° to 200°C), 3°F (1.7°C)TC6-W: Wide Channel Range, Wide Channel ResolutionJ, -55° to 1100°F (-20° to 600°C), 9°F (5°C); K, -145° to 1650°F (-100° to1760°C), 12°F (6.7°C)S, 32° to 3200°F (0° to 1760°C), 41.5°F (23°C); T, -325° to 750°F (-200° to 400°C), 12°F (6.7°C)

TC6Seven-Channel Thermocouple Signal Data Logger

Model 20506

Applications:Monitoring performance of gas-fi red heating equipment, verifying concrete curing temperatures, process verifi cation, etc.

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")Weight 110 g (3.75 oz)

Case Material Noryl® plastic

Battery 3.6 volt Lithium, 1 Amp-HourResolution 8-bit (1 part in 256)Mounting Magnetic backing or locking eyeletClock Accuracy: +/- 2 seconds per daySampling Methods 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)Operating Limits -40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing)PC Requirements Windows PC with at least 256MB RAM, 250MB of free hard drive

space and one free serial or USB portSoftware Requirements TrendReader® 2 [compatible with Windows® XP SP4 (32bit),

Windows Vista SP2 or Windows 7 (32bit or 64bit)]Memory Size 32 K (32,768 readings)Sampling Rates User selectable rates between 8 seconds to once every 5 days

11A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 60: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

58

PS7 Eight-Channel Process Signal Data Logger, #20507

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Eight-Channel: one for the internal temperature sensor andseven external channels for analog voltage and current loopsignals.

Versatile electronic data logger designed for easy recording ofdifferent process signals including the popular 4-20mAand 0-5V.

Uses external transducers (purchase separately below)

Accessories: Trasducer restrictions- compatible with three-wiretransducer (with one power input, one signal output, and onecommon (-) only). Maximum use of one single power supplyonly per logger.

PS7Eight-Channel Process Signal Data Logger

Model 20507

Applications:Monitors a wide variety of measurement parameters including temperature, humidity, power, pressure,wind speed, current, voltage, tank level, fl ow, SCADA troubleshooting, etc.

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")Weight 110 g (3.75 oz)

Case Material Noryl® plastic

Battery 3.6 volt Lithium, 1 Amp-HourResolution 8-bit (1 part in 256)Mounting Magnetic backing or locking eyeletClock Accuracy: +/- 2 seconds per daySampling Methods 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)Operating Limits -40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing)PC Requirements Windows PC with at least 256MB RAM, 250MB of free hard drive

space and one free serial or USB portSoftware Requirements TrendReader® 2 [compatible with Windows® XP SP4 (32bit),

Windows Vista SP2 or Windows 7 (32bit or 64bit)]Memory Size 32 K (32,768 readings)Sampling Rates User selectable rates between 8 seconds to once every 5 days

11A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 61: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

59

TC8 Eight-Channel Temperature Logger, #20508

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Eight-Channel: one for the internal temperature sensor andseven for remote sensing of temperature, resistance, orswitch status.

Multi-point temperature logging. Measures up to eightdifferent locations simultaneously using optional temperatureprobes with various temperature ranges; from as low as-75°F (-60°C) to as 490°F (255°C)

Monitors and records high temperature, low temperature, pipesurface, skin surface, or a variety of other temperatures.

Accessories: ET Thermistor temperature probes, or anyNTC type thermistor probe.

TC8Eight-Channel Temperature Logger

Model 20508

Applications:Food process verifi cation, pharmaceutical and/or laboratory storage, transportation of temperature-sensitive goods, equipment run time, HVAC system testing and balancing, etc.

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")Weight 110 g (3.75 oz)

Case Material Noryl® plastic

Battery 3.6 volt Lithium, 1 Amp-HourResolution 8-bit (1 part in 256)Mounting Magnetic backing or locking eyeletClock Accuracy: +/- 2 seconds per daySampling Methods 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)Operating Limits -40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing)PC Requirements Windows PC with at least 256MB RAM, 250MB of free hard drive

space and one free serial or USB portSoftware Requirements TrendReader® 2 [compatible with Windows® XP SP4 (32bit),

Windows Vista SP2 or Windows 7 (32bit or 64bit)]Memory Size 32 K (32,768 readings)Sampling Rates User selectable rates between 8 seconds to once every 5 days

11A1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 62: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

60

IC-200 Multi-Logger Interface Cable, #20525

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

SS0069_20525

IC-200 Multi-LoggerInterface cable

Model 20525

Page 63: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

61

High Temp Stainless Steel Data Logger, #20615

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

High Temp Stainless Steel Data Logger

Probe Measurement Range -328°F to 500°F (-200°C to 260°C)*Logger Operating Environment -40°F to 302°F (-40°C to 150°C), 0 to 100% R.H.Sensor 100 Platinum RTDTemperature Resolution 0.05°CAccuracy ±0.5°CReading Interval 1 reading every 1 second to 1 every 12 hoursData Format Date and time stamped °F, °C °K, °RData Capacity 32,767 pointsCalibration Digital calibration through softwareBattery 3.6V high-temperature lithium battery included,

1 year typical life Body Dimensions 1.1" x 1.75" dia. (28mm x 45 mm dia)Probe Dimensions 2.0" x 3/16" dia (51mm x 5 mm dia)Weight 8 oz (225 grams)Material 316 Stainless steelCertification CE markWaterproof Level Submersible* For use in temperatures < -40°F (-40°C) or > 302°F (150°C), use Thermal Shield, Model 20623 (see page 2)

Model 20615

Extended temperature range: -40°F to 302°F (-40°C to 150°C)Rugged, submersible and battery powered2" rigid external probe with fast response time, ensuring accurate temperature readingsStorage medium providing maximum data security even if the battery becomes dischargedProgrammable start timeReusableN.I.S.T. traceable

Applications:Hostile environment monitoring, retort sterilization, autoclave validation, food processing and preparation, HACCP programs, ash freezing and chill blast tunnel for prepared and processed foods.

P R O D U C T S P E C I F I C AT I O N S

Page 1 of 2 SS0070_12A2

Page 64: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

62

High Temp Stainless Steel Data Logger Thermal Shield, #20623

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

High Temp Stainless Steel Data Logger Thermal Shield

Ambient Temperature Time In Air To Max Internal Temp(150°C/302°F)

Time In Liquied To Max Internal Temp(150°C/302°F)

-200°C (-328°F) 18 minutes N/A

-180°C (-292°F) 19 minutes N/A

-160°C (-256°F) 21 minutes N/A

-140°C (-220°F) 24 minutes N/A

-120°C (-184°F) 27 minutes N/A

-100°C (-148°F) 32 minutes N/A

-80°C (-112°F) 40 minutes N/A

-60°C (-76°F) 55 minutes 25 minutes

-40°C to +150°C (-40°F to +302°F) Indefinitely Indefinitely

160°C (320°F) 75 minutes 34 minutes

170°C (338°F) 63 minutes 29 minutes

180°C (356°F) 55 minutes 26 minutes

190°C (374°F) 50 minutes 23 minutes

200°C (392°F) 45 minutes 21 minutes

210°C (410°F) 42 minutes 19 minutes

220°C (428°F) 39 minutes 18 minutes

230°C (446°F) 36 minutes 17 minutes

240°C (464°F) 34 minutes 16 minutes

250°C (482°F) 32 minutes 15 minutes

Model 20623

Small diameter (2.6")SubmersibleCan withstand temperatures up to 250°C (482°F)Extreme termperature monitoringFor peanut roasting, can be used in meat and other food processingAutoclave validationConveyer ovens

Applications:Model 20623 is a thermal shield for use with Stainless Steel Data Logger (Model 20615). This durable enclosure can withstand temperature up to 250°C (482°F) and is built for use in applications that require extreme temperature monitoring, such as peanut roasting and food processing.

P R O D U C T S P E C I F I C AT I O N S

Page 2 of 2 SS0070_12A2

Operating Environment -328°F to 482°F (-200°C to 250°C)IP Rating IP68.Dimension/Weight 2.1" x 2.6" dia (53.34mm x 66mm dia.) / 0.65lb (295g)

Page 65: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

63

High Temp Stainless Steel Data Logger, #20616

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

High Temp Stainless Steel Data Logger

Probe Measurement Range -40°F to 500°F (-40°C to 260°C)Operating Environment -40°F to 302°F (-40°C to 150°C), 0 to 95%RH non-condensingSensor 100 Platinum RTDTemperature Resolution 0.05°CAccuracy ±0.5°CReading Interval 1 reading every 1 second to 1 every 12 hoursData Points 32,767 pointsData Format Date and time stamped °F, °C, °K, °RCalibration Digital calibration through softwareBattery 3.6V high-temperature lithium battery included,

1 year typical life Body Dimensions 1.1" x 1.75" dia. (28mm x 45 mm dia)Cable and Probe Dimensions 24" x 0.14" dia. (610mm x 4mm dia) and 4" x 1/8" dia.

(102mm x 4mm dia.)Weight 9 oz (255 grams)Material 316 Stainless steelCertification CE mark

Extended temperature range: -40°F to 500°F (-40°C to 260°C)Rugged, battery powered24" Flexible Te on enclosed cable with a 4" penetration probeStorage medium providing maximum data security even if the battery becomes dischargedProgrammable start timeReusableN.I.S.T. traceableApplications:Perfect for use in medical and pharmaceutical labs, food preparation and processing plants, and other applications involving extreme temperatures.

Model 20616

SS0071_12A1

Page 66: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

64

Ultra Low Temperature Data Logger, #20621

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

Ultra Low Temperature Data Logger

Measurement Range -200°C to 850°C (-328°F to 1562°F)

Resolution 0.01°C(0.018°F)

Accuracy ±0.05°C (±0.09°F) from -200°C to 260°C (-360°F to 468°F)±0.3°C (±0.54°F) from 260°C to 850°C (468°F to 2601530°F)

Channels 1 External

Memory 21,845 readings

Calibration Digital calibration through software

Battery 1 year (3.6V lithium battery included)

Sample Rate 2 seconds up to 12 hours

Dimensions 1.4" x 2.5" x 0.6" (36mm x 64mm x 16mm)

Weight 1.0 oz (28 grams)

Operating Environment -40°C to 80°C (-40°F to 144°F), 0 to 95% RH non-condensing

Certification CE mark

Compact reusable data logger

Real-time operation

Programmable start time

User-friendly

CE Compliant and N.I.S.T. traceable

Model 20621

P R O D U C T S P E C I F I C AT I O N S

The Ultra Low Temperature Data Logger is a miniature, battery powered, stand-alone, precision temperature recorder. The RTD sensor does not suffer from the cold-junction issues of the thermocouple nor the errors at high and low temperatures of the thermistor. The small size allows it to fi t almost anywhere and data retrieval is quick and easy. The device can be started and stopped directly from your computer by simply plugging it into an empty COM or USB port.

10J1

Applications:Calibration chamber monitoring, warehouse monitoring, HVAC, Medical/Pharmaceutical, Museum monitoring, Environmental studies

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 67: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

65

FlashLink CT-80 Data Logger, #20734 - #20737P R O D U C T S P E C I F I C AT I O N S

800-962-6776 www.deltatrak.comP.O. Box 398 Pleasanton CA 94566 (925) 249-2250 Fax (925) 249-2251

FlashLink® CT -80Data Logger

Applications:DeltaTRAK’s FlashLink CT -80 Logger is the ideal device for documenting storage and transport conditions of products sensitive to temperatures down to -80°C (-112°F).

Compact, single-use, in-transit data logger

Ideal for dry ice shipments

Print data using CT Graphics Printer or download data to a PC using CT-USB adapter

Patented Shadow Log™ feature guarantees data even if the operator

forgets to start the device

FlashPDF software option (21 CFR Part 11 Compliant)

Internal Temp. Sensor & Operating Range -80°C to 48°C (-112°F to 118°F)

Temperature Accuracy 0.5°C (±1.0°F) From -60°C to 30°C (-76°F to 86°F) 1°C (±2°F) From -80°C to -60°C (-112°F to -76°F2°C (±3°F) From 30°C to 48°C (86°F to 118°F)

Temperature Resolution 0.1°C/F

Data Capacity 3,824 Data points

Data Download Time 5 seconds

Factory Programmable Alarm Levels High & low limits over entire range

LED Indicators Flashing red for alarm, green for active

Battery Lithium, 3.6v (2)

Dimensions 4.09" x 1.75" (104 mm x 44.5 mm)

Weight 3.4 oz. (99 grams)

Shock Resistance Withstands 3-foot (1 meter) drop to hard surface

IP Rating 68

Certification CE Mark, Calibration Traceable N.I.S.T., RoHS Compliant, BSS 7061 Compliant

Min. System Requirements Windows PC, XP and Vista

Software and Adapter In-Transit FlashLink Software package and/orFlashPDF Software Kit

Model Recording Period

20734 5 Days20735 15 Days20736 45 Days20737 75 Days

11C1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 68: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

66

FlashLink VU In-Transit Data Logger, #20741 - #20748

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FlashLink VUIn-Transit Data Logger

Measurement Range -40°F to 150°F (-40°C to 65°C)Temperature Resolution 0.1°F/°CAccuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C);

±2.0°F above 77°F (±1.0°C above 25°C)±2.0°F below 14°F (±1.0°C below -10°C)

Data Capacity 3824 pointsData Download Time 5 seconds typical for 3800 pointsFactory Programable Alarm Levels High & Low levels over entire range, displayed on LCDBattery (CR2032) 3V Lithium/18 monthsDimensions 1.962" x 3.423" x .575" (50mm x 87mm x 15mm)Casing ABS plasticWeight 1.6 oz. (45.36 grams)Shock Resistance Withstands 3-foot (1 meter) drop to hard surfaceCertification CE Mark, NIST traceable, ROHS CompliantDisplay LCD, Red LED AlarmIP Rating IP56Storage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensationMin. System Requirements Windows PC with 2000, XP or NT operating systemSoftware Requirements In-Transit FlashLink CT Software package #20178, and/or

FlashPDF software package #20163 (both include CT-USB adapter)

Large, easy to read LCD display

Trip history statistics available on LCDPatented Shadow Log feature guaranteesdata even if the operator fails to start the unit, single-use

Print data using Graphics Printer, FlashPDF software or download to PC

NIST traceable and CE Mark

IP56 water-resistant rating

DeltaTRAK’s FlashLink VU Logger is the ideal device for documenting storage and transport conditions of temperature-sensitive products.

®

SS0075_12A1

FlashLink VU with high visibility locator card

RecordingPeriod

Models LoggingIntervals°F °C

5-day 20741 20745 1 min 54 sec15-day 20742 20746 5 min 40 sec45-day 20743 20747 16 min 58 sec75-day 20744 20748 28 min 16 sec

Page 69: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

67

FlashLink USB Reusable Data Logger, #20901

Reusable Data Logger

Measurement Range -40°F to 149°F (-40°C to 65°C)Temperature Resolution 0.1°F/°CAccuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C)/

±2.0°F above 77°F (±1.0°C above 25°C)±2.0°F below 14°F (±1.0°C below -10°C)

Data Capacity 3823 pointsData Download Time 2 seconds typical for 3823 pointsProgramable Alarm Levels High & Low levels over entire range, displayed on LCDBattery (CR2032) 3.6V Lithium/18 monthsDimensions/Body 1.575" x 3.189" x .575" (40mm x 81mm x 13mm)Casing PC/ABS plasticWeight 1.3 oz. (36 grams)Shock Resistance Withstands 3-foot (1 meter) drop to hard surfaceCertification CE Mark, NIST traceable, RoHS CompliantDisplay LCD, Red LED AlarmWaterproof Rating IP67 with silicon cap onStorage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensationMinimum System Requirements Windows PC with XP, or higherProgramming & Downloading Direct USB connection to PC, FlashPDF Program Manager

software (order PN 20412) or USB Program Manager software (PN 20239), and Adobe Reader 7.0 or greater

Single channel, internal sensor for ambient air temperatureUser Programmable: manual or automatic start, sample interval, alarm limits, data tagsLarge, easy to read LCD displayTrip history statistics available on LCDNIST traceable and CE MarkUSB Connection

SS0077_12A1

FlashLink® USB Logger

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Model 20901

Page 70: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

68

FlashLink USB Reusable Data Logger with External Probe, #20902-20903

Reusable Data Logger with External Probe

Probe Measurement Range -40°F to 185°F (-40°C to 85°C)Probe Size: Penetration tip (20902) 0.14in Dia x 3.98in L (3.5mm Dia x 101mm L), 3.28 ft (1m) Teflon cable Blunt tip (20903) 0.15in Dia x 0.98in L (3.8mm Dia x 25mm L), 3.28 ft (1m) Teflon cableTemperature Resolution 0.1°F/°CAccuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C);

±2.0°F above 77°F (±1.0°C above 25°C)±2.0°F below 14°F (±1.0°C below -10°C)

Data Capacity 3823 pointsData Download Time 2 seconds typical for 3823 pointsProgramable Alarm Levels High & Low levels over entire rangeBattery (CR2032) 3.6V Lithium/18 monthsDimensions/Body 1.575" x 3.189" x 0.575" (40mm x 81mm x 13mm)Casing PC/ABS plasticCertification CE Mark, NIST traceable, RoHS CompliantDisplay LCD, Red LED AlarmWaterproof Rating IP67 with silicon cap onStorage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH Minimum System Requirements Windows PC with XP, or higherProgramming & Downloading Direct USB connection to PC, FlashPDF Program Manager software

(order PN 20412) or USB Program Manager software (PN 20239), and Adobe Reader 7.0 or greater

Single channel, external probe for product core temperatureUser Programmable: manual or automatic start, sample interval, alarm limits, data tagsLarge, easy to read LCD displayTrip history statistics available on LCDNIST traceable and CE MarkUSB Connection

SS0119_12A1

FlashLink® USB Logger

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Model 20903Model 20902

Page 71: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

69

FlashLink USB In-Transit Data Logger, #20910-20917

In-Transit Data Logger

Measurement Range -40°F to 149°F (-40°C to 65°C)Temperature Resolution 0.1°F/°CAccuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C);

±2.0°F above 77°F (±1.0°C above 25°C)±2.0°F below 14°F (±1.0°C below -10°C)

Data Capacity 3823 pointsData Download Time 2 seconds typical for 3823 pointsFactory Programable Alarm Levels High & Low levels over entire range, displayed on LCDBattery (CR2032) 3.6V Lithium/18 monthsDimensions/Body 1.575" x 3.189" x .575" (40mm x 81mm x 13mm)Casing PC/ABS plasticWeight 1.3 oz. (36 grams)Shock Resistance Withstands 3-foot (1 meter) drop to hard surfaceCertification CE Mark, NIST traceable, ROHS CompliantDisplay LCD, Red LED AlarmIP Rating IP54 Splashproof (with silicon cap on)Storage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensationMin. System Requirements Windows PC with XP, or higherDownload Requirements Direct USB connection to PC. View data with free FlashPDF software

downloaded from our web site, and Adobe Reader 7.0 or higher

Large, easy to read LCD displayTrip history statistics available on LCDSingle-useUSB ConnectionNIST traceable and CE MarkIP54 water-resistant ratingDownload data as PDF report with free FlashPDF softwarePatented Shadow Log feature guarantees data even if the operator fails to start the unit

DeltaTRAK’s FlashLink USB Logger is the ideal device for documenting storage and transport conditions of temperature-sensitive products.

SS0078_11L2

FlashLink® USB Logger

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

RecordingPeriod

Models LoggingIntervals°F °C

5-day 20910 20914 1 min 54 sec15-day 20911 20915 5 min 40 sec45-day 20912 20916 16 min 58 sec75-day 20913 20917 28 min 16 sec

Page 72: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

70

FlashLink USB In-Transit Tanker Logger, #20920-20921

USB In-Transit Tanker Logger

Single use logger with 15-Day recording period

Large, easy to read LCD display

Trip history statistics available on LCD

Stainless steel probe, cable & submerging weight heat shrink tubing are food grade materials

Weighted probe designed for submersion in glucose syrup

IP54 splashproof logger

Patented Shadow Log feature guarantees data even if the operator fails to start the unit

Model 20920 (°C)Model 20921 (°F)

DeltaTRAK’s USB In-Transit Tanker Logger is ideal for monitoring and documenting temperature of viscous liquids during transport in tankers.

SS0123_11K4

Probe Measurement Range -40°C to 65°C (-40°F to 149°F)

Temperature Resolution 0.1°F/°C

Accuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C); ±2.0°F above 77°F (±1.0°C above 25°C)±2.0°F below 14°F (±1.0°C below -10°C)

Data Capacity 3823 points

Data Download Time 2 seconds typical for 3823 points

Probe Assembly Blunt stainless steel probe with Thermistor sensor and submerging weight; probe dimension: 5/8 in.(1.6 cm), Weight: 0.40 oz; total cable length 8.20ft. (2.5m); length of cable from red marker 4.92ft. (1.5m)

Programable Alarm Levels High & Low levels over entire range

Battery (CR2032) 3.6V Lithium/18 months

Dimensions/Body 1.575" x 3.189" x 0.575" (40mm x 81mm x 13mm)

Casing PC/ABS plastic

Certification CE Mark, NIST traceable, RoHS Compliant

Display LCD, Red LED Alarm

Waterproof Rating IP54 splashproof

Storage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH

Minimum System Requirements Windows PC with XP, or higher

Programming & Downloading Direct USB connection to PC, FlashPDF Program Manager software (order PN 20412) or USB Program Manager software (PN 20238), and Adobe Reader 7.0 or greater

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 73: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

71

Analog Salt Meter - Salinity Refractometer, #24240

Scale Specific Gravity (SG) d20/20; Parts per Thousand (PPT) 0/00

Range 0-100 PPT; 1.000-1.070 SG

Resolution 1.0 PPT; 0.001 SG

Accuracy ±1.0 PPT; ±0.001 SG

Automatic TemperatureCompensation Range

50°F to 86°F (10°C to 30°C)

Dimension 30 mm width x 205 mm length

Weight 207 grams

Focus Manual, adjustable

11D1

Hand-held analog meter

Light-weight, portable, includes protective carrying case

Measures concentration of salt and dissolved solids in aqueous solution

Provides reading in parts per thousand (PPT) and specific gravity (SG)

Automatic Temperature Compensation (ATC)

Ideal for on-site measurements in processing and storage areas, or in the field

Determine salinity during preparation of pickles, seafood products, frozen vegetables and fruits

Analog Salt Meter

Model 24240

Salinity Refractometer

Page 74: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

72

Hand Held pH Meter, #24300

Hand Held pH Meter

Model 24300

Description Hand held, waterproof pH meter. Measures pH, mV and temperature

Probe Types Non-glass pH probes w/BNC connector. Will accept glass probes w/BNC connector

Range pH: 0.00 to 14.00 ±1999 mV Temp: 0 to +100°C (Display °C or °F)

Resolution pH: 0.1/0.01 0.1/1 mV Temp: 0.1 °C or 0.1°F

Accuracy pH: ± 0.01 ±0.1 mV Temp: ±0.5 °C

Display 3-1/2 digit LCD

Temperature Compensation Manual or Automatic 0 to +100 °C

Calibration 1-point or 2-point

Buffer Recognition Automatic at 1.68, 4.01, 6.86, 7.00, 9.18, 10.01, 12.45

Power 9V battery (included), A/C Adapter Optional

Battery Life Up to 200 hours continuous, 10 hour advance low battery warning

Dimensions 3.5"W x 7"H x 1.5"D (90mm x 177mm x 38mm)

Shipping Weight 3.0 lbs (1.3 Kg)

Model 24307 Model 24308Heavy duty, 4.8 mm (.18 in.) piercing meat probe

Standard 8.3mm (.32 in.) diameter probe

Probe Options:

pH meter for non-glass and glass probes with BNC connector

Automatic buffer recognition of 7 buffers

0.1 or 0.01 pH resolution

One or two point pH calibration

Automatic or manual temperature compensation

10J1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 75: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

73

Pocket ISFET pH Meter, #24004

SS0118_11K2

Low cost, non-glass ISFET ph system

Instant response time

Stores dry, requires no fill solution

Replaceable reference electrode (PN 24005)

Auto Shut off

Able to read a single drop of buffer or sample

Quick pH readings of foods, soils, wastewater, pools, and other samples

Model 24004

Sensor Ion Sensitive Field Effect Transistor (ISFET) Replaceable reference electrode

Calibration pH 7.0 buffer, automatic one point calibrationDisplay LCD with pH and TemperatureAutomatic Buffer Recognition pH 7.0

pH 6.86pH Suggested Range 5.0 to 9.0 pH

Range: 2.0 to 12.0 pHResolution: 0.1 pHRepeatability: ± 0.1pH Input Accuracy: 0.1pH

Temperature Operating Temperature Range: 41°F - 104°F (5°C - 40°C) Resolution: 0.1°C or 0.1°FAccuracy: ±1.0°F / 0.5°C

Battery Operation Two 3v (Lithium dry cell CR2032) includedBattery Life Approx. 200 hours of continuous use, warning with 10 hour advance

low battery and automatic power offDimensions 6 1/8"L x 1.1/4"W x 3/4"H (155mmL x 33mmW x 20mmH)Weight 0.17 lbs (77g) meter onlyIP Rating IP67

Page 76: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

74

Digital Thermocouple Thermometer Kit (K Type Probes), #25002 - #25040

Measurement Range (probe) -76.0°F to 1652°F (-60°C to 900°C) dependent on probe attachedOperating Range (base unit) 32 to122°F (0 to 50°C)Display Resolution 0.1°F/°C 33.6 to 391.8°F (-9.9 to 199.9°C), 1.0°F/°C above 391.9°F(200°C)Accuracy ±1% of reading or 1.8°F (1°C) whichever is greaterBattery/Life CR2032 lithium cell/100 hours continuous useBody Dimensions 3 x 1.7 x 0.8 in. (78 x 42 x 20 mm)Weight 1.42 oz. (40.15 grams) including batteryCertification CE Mark, NSFIP Rating IP54 Splash Proof

SS0083_11L1

Ideal for food service and quality control inspectorsNSF Certifi edSwitchable °F/°CFive interchangeable K type probes availableLarge LCD DisplaySplash Proof - IP54

Model 25003 Thermocouple Thermometer Specifications

Model 25002

Digital ThermocoupleThermometer Kit

(K Type Probes)

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 77: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

75

Digital Thermocouple Thermometer Kit (K Type Probes), #25002 - #25040

Digital ThermocoupleThermometer Kit (K Type Probes)Kit includes 25003 base unit, carrying case, 36 inch extension cable and fi ve interchangeable probes:

Thermometer and probes are also available individually.

Model Image Temperature Range25004

Surface Probe7.5" length, 190mm

-76°F to 752°F(-60°C to 400°C)

25005Air/Gas Probe

5.7" length, 144mm

-76°F to 1652°F(-60°C to 900°C)

25006Penetration Probe

5.9" length, 149.86mm

-76°F to 1112°F(-60°C to 600°C)

25007Reduced Tip Probe4" length, 101.6mm

-76°F to 752°F(-60°C to 400°C)

25008Needle Probe

4.4" length, 112mm

-76°F to 1112°F(-60°C to 600°C)

25003Base Unit

25013Extension Cable

User should choose proper probe types for different applications. Make sure the target to be measured will not exceed the temperature range of the probe to avoid permanent damage to the thermocouple probe. EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic fi eld strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.

SS0083_11L1

Page 78: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

76

FlashCheck Ruggy Thermocouple Thermometer Kit, #25054 - #25056

Measurement Range (probe) -76°F to 1112°F (-60°C to 600°C), dependent on probeOperating Range (base unit) 32°F to 122°F (0°C to 50°C)Display Resolution 0.1°F/°C 33.6 to 391.8°F (-9.9 to 199.9°C), 1.0°F/°C above 391.9°F(200°C)Accuracy ±1% of reading or 1.8°F (1°C) whichever is greaterBattery/Life CR2032 lithium cell/100 hours continuous useBody Dimensions 3 x 1.7 x 0.8 in. (78 x 42 x 20 mm)Weight 1.42 oz. (40.15 grams) including batteryCertification CE Mark, NSFIP Rating IP54 Splash Proof

SS0085_11L4 page 1 of 2

Sturdy protective rubber enclosureIdeal for food service and quality control inspectorsNSF Certifi edSwitchable °F/°CThree interchangeable K type probes availableLarge LCD DisplayIP54 Splash Proof

Model 25003 Thermocouple Thermometer Specifi cations

FlashCheck® RuggyThermocouple Thermometer Kit

(K Type Probes)

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Model 25050 w/ Reduced Tip Probe

Model 25051 w/ Surface Probe

Model 25052 w/ Needle Probe

051ob

Page 79: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

77

FlashCheck Ruggy Thermocouple Thermometer Kit, #25054 - #25056

FlashCheck Ruggy Thermocouple K Type Probes

Thermometer and probes are also available individually.

EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic fi eld strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.

Kit includes 25003 base unit, boot and 1 probe. Extra probes sold separately.

Model Image Temperature Range

25054Reduced Tip Probe

(4" long, 101.6mm, tip dia. 2.33mm w/39.56mm cable)

-76°F to 752°F(-60°C to 400°C)

25055Surface Probe(7.5" long, 190mm w/39.56mm cable)

-76°F to 752°F(-60°C to 400°C)

25056Needle Probe

(4.4"long, 112mm, tip dia. 1.6mm w/39.56mm cable)

-76°F to 1112°F(-60°C to 600°C)

25003Base Unit

25053Rubber Enclosure

Cal tool

SS0085_11L4page 2 of 2

Page 80: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

78

Heat/Cool Digital Cooking Thermometer, #26003

HEAT/COOLAutomated Cooking and Cool Down Thermometer

Model 26003

"Auto-Cal" button

Measurement Range 32°F to 338°F (0°C to 170°C)Operating Range (base unit) -22°F to 122°F (-30°C to 50°C)Accuracy 0°F to 275°F ± 1.8°F (0°C to 135°C ±1.0°C)

275°F to 302°F ± 2.7°F (135° to 150°C ±1.5°C) Probe 6.5” (17cm) stainless steel, reduced tip. DetachableProbe Wire 30” (76cm) heat-resistant TeflonTimer Up to 23 hr 59 min. in count up or down modesBody ABS plastic Unit Weight 3.8oz (107.7g)Resolution 0.1°(F or C)Battery Two 1.5V button, battery life 18 monthsCertification CE, factory calibrated to NIST standards, RoHS compliant

Fully automated time/temperature monitering for food cool down• Programmable time/temperature settings, 3 zones• Confi rms less than 6 hour total cool down time for food safety and compliance with FDA

Food Code 3-501.14 (A,B)• Audible alarm if food exceeds time in temperature danger zoneNew "Auto-Calibration" feature• Uses ice bath reference solutionCount down or count up timer for cooking and coolingAudible alarms for PASS/FAIL notification and unattended operationEasy to clean heat resistant Teflon® wire and waterproof probeHACCP Compliance toolIncludes removable mounting cradle

SS0087_11L1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 81: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

79

Pocket Dial Thermometer, #29001/#29007/#29009

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

1" Bimetal DialThermometer

1"/2.5 cm magnifi ed dialWaterproofShatterproofPolycarbonate lensStainless steel housing

Field calibratableAdjustable stainless steel clipPocket clipCover can be used as handle extensionTarget range indication

Temperature Range 10°F to 220°F (12°C to 105°C)Calibration Simple hex-nut calibrationStem 5 in/13.7 cm Accuracy ±6°F from 32°F to 165°F (±3.3°C from 0°C to 74°C)

Applications: Perfect for small frothing pitchers

SS0088_11L1

Model 29009 Model 29007 Model 29001

NSF Certifi ed °C Scaled °F/°C Scaled

Page 82: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

80

Pocket Dial Thermometer, #29002/#29003

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

SS0089_12A1DeltaTRAK manufactures data loggers under an ISO 9000 registered quality management system

DIAL THERMOMETER

Model 29003 Model 29002

Temp Range 0°F to 220°F-20°C to 105°C

0°F to 220°F-20°C to 105°C

Accuracy ±2°F(±1°C) ±6°F from 32°F to 165°F(±3.3°C from 0°C to 74°C)

NSF Certified Yes NoDescription 1.75 inch (44mm) dial with dual °C/°F scale

Probe 5inch (128mm) stainless steelCalibration Simple hex-nut calibration

Weight 0.6oz (16gm)

Bi-Metal

Model 29003 Model 29002NSF Certifi ed Dual Scale Dual Scale

Applications: Pefect for small frothing pitchers

1.75" / 2.5 cm magnifi ed dialBi-metal coil mechanismWaterproof

Field CalibrationPlastic probe cover with pocket clip

Page 83: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

81

Freezer/Refrigerator Thermometer, #29004

Freezer-Refrigerator Thermometer

Durable, heavy-duty stainless steel

Hang or stand

Large, easy-to-read face

Applications:Easy to read bold numbers made of stainless steel. The bi-metal design uses a coiled element fi xed at one end and is attached to the pointer. As the temperature increases, the pointer will be rotated by the coiled bi-metal element indicating the correct temperature. Used to assure your refrigerator and freezer are at the desired temperature to keep food fresh.

Model 29004

Temperature Range -20°F to 86°F-30°C to 30°C

Temperature Accuracy ±2°F (±1°C)

Dimensions 2 inch/5 cm diameter

Housing Material Stainless steel constructionNSF Certified Yes

SS0090_11K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 84: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

82

Oven Thermometer, #29005

OVEN THERMOMETER

Stainless steel and Template glass

Readings in Fahrenheit or Celsius

Heat-resistant to 600°F (315°C) degrees

Applications:

Displays oven temperature on a clearly readable scale. Made of stainless steel, with a 50mm (2") dialface and features bi-metal coil movement with a glass lens. Hangs or stands. NSF Certifi ed.

Model 29005

Temperature Range 200°F to 600°F (93°C to 316°C)Temperature Accuracy ±25°F (±12.5°C) at 25% and 75% of the temperature scale 93.3°C to

315.6°C)Dimensions 2 inch / 5 cm diameterHousing Material Stainless steel constructionNSF Certified Yes

SS0091_11K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 85: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

83

Freezer/Refrigerator Thermometer, #29006

Refrigerator-Freezer Thermometer

Applications:The numbers used to adjust the temperature on most refrigerators only raise or lower the temperature. They usually do not refl ect the real temperatures in your fridge. A different measurement may be needed to monitor and maintain the true temperature. Using a refrigerator thermometer is the only way to assure your refrigerator is at the correcttemperature.

40°F or lower is the recommended refrigerator temperature to slow bacterial growth and maintain food quality. On the other side, freezing occurs at 32°F. Adjust refrigerator accordingly between 32°F and 40°F to prevent unwanted freezing, such as freezing milk.

Model 29006

Place the Refrigerator Thermometer in the front of the fridge in an easy-to-read location. Check temperature regularly, at least once a week.

Stainless steel

Readings in Fahrenheit or Celsius

Easy to read

NSF Certifi ed

SS0092_11K1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Temperature Range -40°F to 80°F-40°C to 27°C

Temperature Accuracy ±2°F (±1°C)Dimensions 120 mm x 30 mmLens Material Polycarbonate (non-mercuric column)NSF Certified Yes

Page 86: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

84

Grill Thermometer, #29010

Measurement Range 100°F to 500°F( 38°C to 260°C)

Accuracy ±10°F (±5.5°C)

Temperature Unit °F /°C Dual Scale

Dimensions 56.7mm (D)x 20mm(H) (2.23” x 0.79”)

Housing Material Stainless steel

DeltaTRAK’s Grill Surface Thermometer is the ideal device for monitoring the temperature of cooking surfaces, such as flat top grills, griddles, and barbeque grills. It can also be used on hot-holding tables and carving station warmers.

Model 29010

Durable, heavy duty stainless steel

Easy-to-read dial face

Tabs for lifting up

NSF certified

Page 87: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

85

FlashLink Mini Intransit Data Logger, #30013-30016

Recording Period

Models with shipping envelope

Models with utility sleeve

Logging Intervals

5-day 30013 30013S 1 min. 54 sec.

15-day 30014 30014S 5 min. 40 sec.

45-day 30015 30015S 16 min. 58 sec.

75-day 30016 30016S 28 min. 16 sec.

Ideal for documenting storage and transport conditions of temperature sensitive products.

Compact, single-use, in-transit data logger

Print data using CT Graphics Printer or download to a PC using CT-USB adapter

Patented Shadow Log™ feature guarantees data even when the unit is not activated

Operating Range -40°F to 150°F (-40°C to 66°C)

Temperature Accuracy ±1.0°F (0.5°C) From 32°F to 150°F (0°C to 66°C)±2.0°F (1.0°C) over entire range

Temperature Resolution 0.1°F/°C

Data Capacity 3,823 data points

Data Download Time 5 seconds

Factory Programmable Alarm Levels

High & Low levels over entire range

LED Indicators Flashing red for alarm, green for active

Battery Type Lithium coin 3v

Dimensions/Enclosure 3.44" L x 2.07" W x 0.57" H; (87.38mm L x 52.72mm W x 14.65mm H;) ABS plastic case

Weight 1 oz. (28g)

Certification CE Mark, NIST traceable, RoHS compliant

Software Requirements In-Transit FlashLink CT Software Package #20178, or FlashPDF Software Package 20163 (both include CT-USB adapter) and Adobe Reader 7.0 or greater

SS0120_11K2DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 88: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

86

Kitchen Timer, Count Down/ Up, #50007

Kitchen TimerCount Down/Up

Maximum count down/up range 19 hours, 59 minutesDisplay resolution 1 second

Display size 1.85 in. W x .78 in. H (47mm W x 20mm H)Digital size .33 in W x .70 in H (8.3mm W x 18mm H)Battery 1.5 volt, Size AAA Product size 2.48 in W x 2.48 in H x .59 in D

(63mm W x 63mm H x 15mm D) excluding clip

Large LCD display19 hour, 59 minute count up or downLoud buzzer soundFolding standMagnet on back

Applications:The kitchen timer is useful for timing the cooking or cool down of foods in restaurants and all food service areas. The large, easy-to-read display shows at a glance the time and the loud buzzer can be heard in busy areas.

Model 50007

SS0093_11L1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 89: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

87

Alcohol Wipes, #50009

Alcohol Wipes

Certificates CE certificate, ISO: 2003Ingredients 70% Isopropyl alcohol and 30% distilled waterBoiling point 82.5°C (180.5°F)Relative Density 0.7851Dimensions 2.4" x 1.2" (61 mm x 31 mm) each wipePackage 200 PCS/box, 4000 PCs/case

Model 50009

Alcohol Prep Pads are primarily used in the food service and processing facilities for sanitization to meet HACCP and food safety requirements. Each soft absorbent, non-woven pad is saturated with 70% isopropyl alcohol. Individually wrapped alcohol wipes are also ideal for cleaning and sanitizing thermometer probes. It is imperative that probes and other tools are sanitized before and after each use to prevent cross-contamination. Each pre-moistened pad measures 61 mm x 31 mm.

Premium, nonwoven pad material saturated with 70% isopropyl alcohol

Cleans and sanitizes

Sealed in air-tight, poly-lined foil pouches

Cost effective

SS0094_10J1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 90: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

88

pH Plastic Indicator Strips, #50012

pH Plastic Indicator Strips

Reference Chart 0.0 to 6.0 pH range, subdivision 0.5 pH unitPackage 300 test strips, 1 color chart

Size of 1 strip 0.25" W x 2.5" L (7mm W x 63mm L)

SS0095_12A1

Immediate response

Direct reading pH stick with clear, bright color matches over the desired pH range

Easy to match color with color chart included

Economical pack contains 300 strips

Model 50012

The 0.0 - 6.0 pH Dip-Stik strips are simple to use and require no technical training. To measure the pH of a solution, simply dip the test strip into the solution and match the resulting color change with the pH color chart.

Page 91: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

89

Quat Ammonium Test Papers, #50013

Quat Ammonium Test Papers

Reference Chart 0, 100, 200, 300, 400 (ppm)Package 3 rolls, 1 plastic dispenser, 1 color chart

Size of Roll 5/32 in W x 15 ft L (4 mm W x 4.6m L)

SS0096_12A1

Simple test procedure requires no technical training

Easy to match color with color chart included

User-friendly dispenser package

Economical pack provides approximately 100 tests

Need a quick and easy method to ensure you are effectively sanitizing food surfaces? Quat Test Pa-pers are the answer. The Hydrion QT-10 test paper provides a simple and reliable method to verify the strength of Quaternary Ammonium sanitizers and ensure compliance with the food safety laws enforced by federal, state, and local health departments.

The Test Papers give accurate readings when properly used: • Get room temperature test solution (65°F -75°F) • Immerse test strip in still solution for 10 seconds • Compare color against the color chart.

Model 50013

Page 92: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

90

Chlorine Test Papers, #50014

Chlorine Test Papers

Reference Chart 10-50-100-200ppmPackage 6 rolls, 1 plastic dispenser, 1 color chart

Size of Roll 5/32 in W x 15 ft L (4mm W x 4.6m L)

SS0097_12A1

Model 50014

Simple test procedure requires no technical training

Easy to match color with color chart included

Reliable color matching at 10-50-100-200ppm

User-friendly dispenser package

Economical pack provides over 200 tests

Users of chlorine based sanitizer solutions are required to have test kits on hand to ensure their sanitizer solutions meet federal and state health department requirements. The Hydrion Chlorine Test Papers measure the concentration of chlorine based sanitizer solutions. They provide the user with a simple, reliable, and economical means of meeting federal and state health requirements. Simply dip the test strip in the chlorine sanitizer solution and compare color against the color chart. These test papers are approved by health department to be used for monitoring concentrations of chlorine sanitizing solutions.

Page 93: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

91

FlashCheck Bacteria Enzyme Detection Kit - Real-time Surface Assay, #50025-50026

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FlashCheck Bacterial Enzyme Detection KitReal-time Surface Assay

Detect Bacteria on the spot

Results in 20 minutes or Less

Detects the presence of Biofi lm

No Growth Required

Detect presence of Gram Negative Bacteria or Total Organisms

Easy-to-Read Results

Accuracy Greater than 98% if more than 1,000 organisms present per test strip

No Equipment Needed

11H1

Notes of the Test: The FlashCheck Bacterial Enzyme Detection Kit is a screening test for the presence of bacteria; it does not distinguish between different types of bacteria. However, a positive reaction indicates the potential presence of pathogenic bacteria which may be in suffi cient quantities to cause illness or spoilage. Although defi nite acceptable levels of contamination have not been set for most surfaces, research states that if a surface tested has greater than 106 organisms present, the potential for illness and spoilage exists. The lower limit of detection for the Gram Negative Bacteria test is 103 organisms per test membrane, which allows for the presence of normal background bacteria, while not causing a reaction to occur. If a surface is to be tested, and the results compared with culture, it is important that equal areas be surveyed, and that equal conditions exist on both surfaces.

Model 50025 Total Organisms KitModel 50026 Gram Negative Kit

Model Number: 50025 50026

Type of Assay: Total Organisms (Bacteria) Gram Negative Bacteria

Applications: Surfaces and equipment Surfaces and equipment

Contents of Kit: 50 Membrane Test Strips;1 Bottle of Reagent A;1 Bottle of Reagent B;1 Bottle of Reagent C;1 Bottle of Positive Control;1 Timer1 product insert with instructions

50 Membrane Test Strips;1 Bottle of Reagent A;1 Bottle of Reagent B;1 Bottle of Reagent C;1 Bottle of Positive Control;1 Timer1 product insert with instructions

Storage Conditions: 35°F to 47°F (2°C to 8°C); 35°F to 47°F (2°C to 8°C);

Transport Conditions: 35°F to 77°F (2°C to 25°C) 35°F to 77°F (2°C to 25°C)

Shelf Life: 6 months at room temperature;18 months if refrigerated

6 months at room temperature;18 months if refrigerated

Refi ll Kit No.: Model 50038 Model 50039

Page 94: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

92

FlashCheck Bacteria Enzyme Detection Kit - Real-time Food Surface Assay, #50027

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FlashCheck Bacterial Enzyme Detection Kit

11D2

Model 50027

Notes of the test: Model 50027 is a screening test for the presence of gram negative bacteria. It does not distinguish between different types of bacteria. However, a positive reaction is indicative for the pathogenic bacteria which maybe in suffi cient quantities to cause illness or spoilage. The kit does not detect all strains of Campylobacter. It has not been tested on all food products. Therefore, there maybe some food products that react with other reagents.

Real-time Food Surface Assay - Gram Negative Bacteria

Model Number: 50027

Type of Assay: Gram Negative Bacteria (Enterobacteriaceae)

Applications: Surfaces of Food

Contents of Kit: 50 Test Swabs (w/substrate);1 Bottle of Reagent A;1 Bottle of Reagent B;1 Bottle of Positive Control;1 Timer1 product insert with instructions

Storage Conditions: 35°F to 77°F (2°C to 25°C);

Transport Conditions: 35°F to 77°F (2°C to 25°C)

Shelf Life: 18 months at room temperature;

Refi ll Kit No.: Model 50040

Detect Bacteria on the spot

Results in 20 minutes or Less

Detects the presence of Biofi lm

No Growth Required

Detect presence of Gram Negative Bacteria (Enterobacteriaceae)

Easy-to-Read Results

Accuracy Greater than 98% if more than 1,000 organisms present per test swab

No Equipment Needed

Page 95: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

93

FluoreCheck Bacteria Enzyme Detection - FluoreCheck Real-time Fluorometer, #50028-50029

Fastest Detection of Low Levels of Bacteria from time of sample

Detects as low as 1 CFU per 100 ml liquid or 1 CFU per 25 grams of a food product *

Ideal screening tool for Liquids, Surfaces or Food products

Easy to read results in minutes

Detects specific enzymes produced by specific microorganisms or bacteria:

(Salmonella, E.coli, Fecal Coliforms, Enterococcus, S.aureus)

General screening for Total Organisms or Gram Negative Bacteria (Enterobacteriaceae)

Note: * 4 hours incubation from the time of sample collection may be needed in low level of bacteria conditions. Postitive readings may occur in conditions of higher levels of bactera in less than 4 hours.

Model 50028, Low Wave Length Model 50029, High Wave Length

Model Number: 50028 50029

Wave Length: Low High

Applications: Liquids, Surfaces, Equipment, Food Liquids, Surfaces, Equipment, Food

Assays: E.coli Enterococcus S.aureus Salmonella Gram Negative Bacteria Total Organisms

Fecal Coliforms

Sensitivity:: 1 CFU per 100 ml liquid 1 CFU per 25 grams of a food product

1 CFU per 100 ml liquid 1 CFU per 25 grams of a food product

Specificity: >98% >98%

Readings: A positive test is any numerical value above 250. A zero reading, as well as a reading below 250, is a negative test

A positive test is any numerical value above 250. A zero reading, as well as a reading below 250, is a negative test

Size: 7" long x 3.75" wide x 1.75 deep (17.8cm x 9.5cm x 4.4cm)

7" long x 3.75" wide x 1.75 deep (17.8cm x 9.5cm x 4.4cm)

AC Power: 100 - 240V external power supply (included) or 4 AA batteries internal

100 - 240V external power supply (included) or 4 AA batteries internal

Page 96: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

94

FluoreCheck Bacteria Enzyme Detection Kits - Real-Time Assay, #50031-50037

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

FluoreCheck Bacterial Enzyme Detection Kits

11F1

Real-time Assay

Detect Bacteria on the spot

Readings in as little as 10 minutes

Proprietary Fluorogenic Substrates

Detects specifi c enzymes produced by specifi c microorganisms or bacteria

Easy-to-Read Results

Accuracy Greater than 98%

yReal-time Assay

pot

Type of Assay Salmonella E.coli Fecal Coliforms S.aureus Enterococcus Gram Negative Bacteria

Total Organisms

Model No.: 50036 50031 50033 50035 50032 50034 50037Applications: Liquids,

Surfaces, Food Products

Liquids, Surfaces, Food Products

Liquids, Surfaces, Food Products

Liquids, Surfaces, Food Products

Liquids, Surfaces, Food Products

Liquids, Surfaces, Food Products

Liquids, Surfaces, Food Products

Contents of Kit:Rayon Test SwabsReagents:

Substrate:Enzyme Inducer:

Lysing Agent:Test Vials3mm Sample BottlesInstructionsTraceability Labels

Contents of Kit:50 ea.

2 BottlesReagent A

------Reagent B

50 ea.50 ea.

Yes 50 ea.

Contents of Kit:50 ea.

3 BottlesReagent AReagent BReagent C

50 ea.50 ea.

Yes 50 ea.

Contents of Kit:50 ea.

3 BottlesReagent AReagent BReagent C

50 ea.50 ea.

Yes 50 ea.

Contents of Kit:50 ea.

2 BottlesReagent A

------Reagent B

50 ea.50 ea.

Yes 50 ea.

Contents of Kit:50 ea.

3 BottlesReagent AReagent BReagent C

50 ea.50 ea.

Yes 50 ea.

Contents of Kit:50 ea.

3 BottlesReagent AReagent BReagent C

50 ea.50 ea.

Yes 50 ea.

Contents of Kit:50 ea.

3 BottlesReagent AReagent BReagent C

50 ea.50 ea.

Yes 50 ea.

Storage Conditions 35°F to 47°F (2°C to 8°C)

35°F to 47°F (2°C to 8°C)

35°F to 47°F (2°C to 8°C)

35°F to 47°F (2°C to 8°C)

35°F to 47°F (2°C to 8°C)

35°F to 47°F (2°C to 8°C)

35°F to 47°F (2°C to 8°C)

Transport Conditions 35°F to 77°F (2°C to 25°C)

35°F to 77°F (2°C to 25°C)

35°F to 77°F (2°C to 25°C)

35°F to 77°F (2°C to 25°C)

35°F to 77°F (2°C to 25°C)

35°F to 77°F (2°C to 25°C)

35°F to 77°F (2°C to 25°C)

Shelf Life 18 months if refrigerated

18 months if refrigerated

18 months if refrigerated

18 months if refrigerated

18 months if refrigerated

18 months if refrigerated

18 months if refrigerated

Fluorometer Model 50028 50028 50029 50028 50028 50028 50028

Growth Mediano growth:

If growth needed:Sterile waterRapp-Vass R10 broth

Sterile waterLauryl tryptose broth

Sterile waterLauryl tryptose broth

Sterile waterStaphylococcus broth

Sterile waterEnterococcus Confi rmation broth

Sterile waterNutrient broth

Sterile waterNutrient broth

Notes: Assays for additional forms of microorganisms and bacteria may be available upon request. Listeria will be available soon.

Page 97: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

95

High Temperature Thermolabels, page 1, #50109 - #50809

High Temperature

1-Temperature ThermoLabelSelf-adhesive white label ½" x 1 ¾", completely

sealed with a clear plastic overlay. Turns black at indi-cated temperature which is indelibly imprinted on eachlabel. Can be used under all industrial conditions:water, steam, humidity, oils, grease, solvents, andchemical contamination. Ideal for dishwashers, animalcage washers, autoclaves, ovens, etc. 43 different tem-perature settings range from 90°F (32°C) to 500°F (260°C).

3-Temperature ThermoLabelSimilar to the 1-temperature label, it is also sealed witha clear plastic overlay for use under all conditions. Itmeasures 1" x ¾" and has two temperature combinations with three elements on each: 150°-160°-170°F (66°-71°-77°C) and 160°-170°-180°F (71°-77°-82°C).

AFTER

5 to 10 second response time

ThermoLabels

Available in 1-Temperature, 3-Temperature, 5-Temperature and 8-Temperature Strips

5-Temperature ThermoLabel Has five temperature elements on a single strip,white with clear plastic overlay, but not completelysealed and cannot be used under liquid conditions.Each element reacts within a few seconds when itsrated temperature is reached, and that sectionchanges from white to black with its indelibly printed temperature clearly visible. Ratings fall within anoverall range of 90°F to 500°F (32.2°C to 260°C).Available in ten different temperature combinations.

8-Temperature ThermoLabelSimilar specifications to the 5-Temperature label, it also cannot be used under liquid conditions.It has eight temperature elements on a single strip,and ratings fall within an overall range of 100°F to500°F (37.8°C to 260°C). Available in nine differenttemperature combinations.

Provides a permanent record ofinternal or external temperature of a product or equipment over time.Used during manufacture/process-ing, storage, shipping, in curing andsterilization chambers, retort opera-tions, in ovens, washers, dryers,cargo holds, etc.

Disposable, color-changing temperature indicators

Indefinite life when stored in a cool dry place, below 80°F (27°C)

±1% of stated temperature accuracy

BEFORE

160°F 71°C

180°F 82°C

170°F 77°C

160°F 71°C

180°F 82°C

170°F 77°C

160°F 71°C

140°F60°C

180°F82°C

170°F77°C

160°F71°C

150°F65.6°C

250°F121°C

310°F154°C

300°F149°C

290°F143°C

280°F138°C

270°F132°C

260°F127°C

320°F160°C

160°F 71°C

SS0101_11L1

Page 98: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

96

High Temperature Thermolabels, page 2, #50109 - #50809

SS0101_11L1

Page 99: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

97

Coldmark Thermolabels, page 1, #51001 - #51002

Temperature Range 51001 32°F / 0°C51002 26°F / -3°C

Accuracy ±1°C (1.8°F) of the response temperature

10L1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Protects products that are sensitive to extremely cold temperatures

Stick-on labels can be applied to a product, package, carton or master pack

Tamper proof method of verifying when freeze damage has occurred during

shipping, storage, or handling

COLDMARKThermoLabels

Model 51001

Model 51002

32°F / 0°C

26°F / -3°C

Page 100: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

98

Coldmark Thermolabels, page 2, #51001 - #51002

Before exposure, bulb is colorless.

After exposure,bulb turns violet.

Here’s How COLDMARK Works

The COLDMARK Indicator tube and bulb contain a specially formulated colorless fluid, a violet-colored fluid, and a green colored fluid separating the two.

When the indicator is exposed to a temperature at or below the response temperature within 60 minutes, the colorless bulb solidifies and contracts. This draws the colored liquids into the bulb and changes from clear and colorless to cloudy with streaks of violet. When the indicator is warmed to above the response temperature again, the bulb changes irreversibly to a uniform violet.

Application is simple

COLDMARK’s construction makes it fast and simple to add the benefits of temperature monitoring to your product.

Simply peel the release liner off the back of the indicator and adhere the pressure-sensitive adhesive backing to a dry surface. You can place the indicator on the exterior or interior of a shipping container. (COLDMARK indicators should not be placed where they are exposed to crushing pressure.)

Storage

Color change is irreversible and tamper-proof.

COLDMARK Indicators must be stored above their response temperature and should not be exposed to temperatures exceeding 110°F/ 43°C.

ColdMark TM

THERMO LABELS

Page 101: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

99

WarmMark Thermolabels. page 1, #51013 - #51035

WARMMARKTHERMOLABELS

-18°C/ 0°FModel 51034

0°C/ 32°FModel 51013

5°C/ 41°FModel 51014

30°C/ 86°FModel 51020

37°C/ 99°FModel 51021

20°C/ 68°FModel 51018

8°C/ 46°FModel 51022

10°C/ 50°F Model 51017

25°C/ 77°FModel 51035

BEFORE AFTER

Temperature Range -18°C/0°F to37°C/ 99°F

Accuracy ±1°C of its response temperature

Tag Size .75 in. x 1.81 in. x .06 in.; (1.9 cm x 4.6 cm x .15 cm)

10J1

Designed for accurate time/ temperature monitoring at the lowest possible cost

Provides a permanent temperature exposure record that assures your customers of consistent

quality

A blotter paper pad saturated with a red-dyed chemical is specially formulated to melt at the tag’s

response temperature

Available in a variety of response temperatures

Easy to use

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 102: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

100

WarmMark Thermolabels, page 2, #51013 - #51035

WARMMARKTHERMOLABELS

10J1

Page 103: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

101

Tempdot Time-Temperature Labels, Model #51030 - #51032

P.O. Box 398 P leasanton CA 94566 (925) 249-2250 Fax (925) 249-22511-800-962-6776 www.deltatrak.com

P R O D U C T S P E C I F I C AT I O N S

Tempdot®

Total Accumulative Time 60 min.

Size 1.5"H x .75"W (3.8cm x 1.8cm)

Package 50 labels per package

10J1

Low Cost

2 year shelf life

Variety of temperature ranges

Easy to apply adhesive backing

Provides accumulative temperature abuse exposure time over threshold temperature in degree minutes

Time-Temperature Labels

DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 104: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

102

FreezeCheck Thermolabels, #54000

Thermolabels

Response Temperature 0°C /32°F

Temperature Accuracy +0°F/-2.7°F (+0°C/-1.5°C)

Size 1.125" x 2.375"

Characteristics Irreversible color change from clear to white and the green check mark is no longer visible

Storage Room temperature or below

Shelf Life 2 years, stored in a cool, dry place

Tamperproof method for verifying when freeze damage has occurred during ship-ping, storage, or handling.

Indicates temperature abuse for products that are sensitive to lower limit temperature excursions.

Adhesive labels can be applied to a product, package,carton or master pack.

The Freeze Check Thermolabel is used to indicate an out of range temperature excursion below

32°F (0°C). When the temperature drops below the threshold, the indicator changes irreversibly from

clear to white and the green check mark is no longer visible.

FreezeCheck

BEFORE AFTER

Model 5400032°F/0°C

10J1DeltaTRAK manufactures products under an ISO 9000 registered quality management system

Page 105: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

103

TempDot High Temperature Thermal Label, #54114/#53146

High Temperature Dishwasher Thermolabels

Verifies compliance with FDA Food Code 4-703.11 (B) for sanitization

Waterproof

Adhesive back

Disposable, irreversible temperature indicators

BEFORE AFTER

High Temperature Dishwasher Thermolabels provide a permanent record of temperature change in

commercial dishwashers and warewashers. This validates that dish, utensil, or kitchenware surface has

reached its designated sanitation temperature.

Model 53146: 24 labelsModel 54114: 144 labels

Tempdot®

Thermochromic color change

Response Temperature 160°F (71°C)

Temperature Accuracy ±2°F, ±1°C

Size 0.91" x 0.91"; 23 mm x 23 mm

Packaging Model 53146: 12 labels/sheet x 2 sheets, total 24 labels per packageModel 54114: 12 labels/sheet x 12 sheets, total 144 labels per package

Characteristics Irreversible color change from dark to orangeLabel can be removed from dishware without leaving adhesive residue, and affixed to log book for record keeping

Storage Store below 80°F (26°C). Do not expose to sunlight or other UV light, or heat source such as air vents, pipes or appliances

Shelf Life 2 years, under recommended storage conditions

SS0106_12A1

Page 106: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

104

Air Repair Ethylene Absorbers, #19007 - 19011

Ethylene AbsorbersYour Key of Protection

Product Specifications

DeltaTRAK, Inc / P.O. Box 398 / Pleasanton, CA 94566 1-800-962-6776 Fax: 925-249-2251 www.deltatrak.com

Sps_AirRepair_2010_rev0223- 1 -

GUIDELINES FOR CALCULATING THE AMOUNT OF PROTECTION TO BE USEDGroup I Group II Group III

Factor .00001 Factor .00002 Factor .00003Fruit Vegetables Fruit FruitBerries Artichoke Breadfruit Apple MangosteenCherry Asparagus Guava Apricot NectarineGrapefruit Beans Jackfruit Avocado Passion FruitGrapes Beets Kiwifruit Banana PeachLemon Broccoli Lychee Cantaloupe Pears (all)Limes (all) Brussel Sprouts Plantain Cherimoya PersimmonOranges Cabbage (all) Quince Crenshaw PlumPineapple Carrots Tamarillo Persian SapotaPomegranate Caulifl ower Tomatoes Honeydew Tomatoes (pink)Mandarins Celeriac MangoTangerines Celery

Chard

FORMULACalculating Factor x Days to be Protected x Weight of Merchandise = Size #

ExampleA 40 ft containerized shipment is leaving New York for a Caribbean Island. Estimated time of travel tothat island is fi ve (5) days.The total weight of the merchandise is 36,000 lbs.Half the items being shipped are found in Group I.The remainder of the merchandise are items found in Group III. We then calculate as follows: .00001 x 18,000 x 5 = .9 (C.F.) Wt.) (days) .00003 x 18,000 x 5 = 2.7 .9 + 2.7 = 3.6 Use one size #3 and one size #1 (3 and 1 = 4)

TubesSize Model

#1 (20") 19007

Blankets Size Model

#1 (10" x 10") 19011#3 (20" x 14") Not Available#5 (20" x 20") 19008#6 (20" x 25") 19009

Page 107: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

105

Air Repair - Application Guidelines

Mini-Packets: Place in each box of produce or flowers prior to shipment or storage.Best if placed into the box directly on the packing line. This way Air Repair ™ will protect the product from the time it is packaged, throughout distribution and storage, until it reaches the retail level.

The 5 gram mini-bag is recommended for floral applications. Staple or tape the bagto the top edge, closure flap, or cover of each box. If using tape be sure that you onlyuse a strip small enough to attach the bag without covering too much of it, so air can stillcirculate through the material and the absorber beads.

One 8 gram mini-bag is recommended for produce applications, for a 10 to 15lb boxtraveling on short trips (20 days or less) with minimal cold storage. For longer trips,two 8 gram mini-bags are recommended in a 15 to 20 lb box. Instead of stapling ortaping, the mini-packet can also be placed directly on top of the produce, as long as thereisn’t a lot of moisture present. If so, then stapling or taping will make sure that the mini-packet is hanging, thus less likely to get wet.

Mini- Tube (5”): Used for small walk-in coolers or refrigerated display cases in floralretail stores. Clip onto the fan guard, of fasten with a twist tie or wire, or free-standingon a shelf.

Tube (20”): Used in refrigerated containers where space is tight or in manifold systemfor forced air return. Can also be used in small walk-in coolers, fasten to a fan guard, or hanging, suspended in the air flow (preferably the return side).

Mini-Blanket (10” x 10”): Same application as the tubes, except hangs in the air flow,again, preferably on the return side of the fans.

Blankets: Most popular size is the #6 blanket (20” x 25”), there is also a #5 (20” x 20”)blanket. Use inside ocean containers, large coolers or in warehouses. In an oceancontainer two 20” x 25” blankets are usually sufficient, hang from the ceiling.

Ethylene AbsorbersApplication Guidelines

Product Specifications

-2 -

DeltaTRAK, Inc / P.O. Box 398 / Pleasanton, CA 94566 1-800-962-6776 Fax: 925-249-2251 www.deltatrak.com

Page 108: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

106

Air Repair - Application Guidelines

Ethylene AbsorbersApplication Guidelines

Product Specifications

BASIC ETHYLENE MANAGEMENT IN PRODUCE & FLORAL HANDLING

Exposure of horticultural products to ethylene gas during storage, distribution and at the retail level, can cause increasedshrinkage and a decline in quality and shelf life. Following is some information to aid in ethylene management for floral

and produce handling.

MINIMIZE OR ELIMINATE SOURCES

It is important to identify some basic sources of ethylene which could be present in your handling environment. The first phase of good ethylene management, after identification, if elimination, reduction or isolation of different sources of ethyl-ene. These include:

Exhaust Fumes - Combustion engines powered by fossil fuel give off significant amounts of ethylene in their exhaust, upto 300 ppm. Forklifts, trucks and airplanes in the distribution chain, even heavy traffic or busy parking lots can be signifi-cant sources of ethylene. If elimination of engine exhaust is impossible, then ample ventilation must be provided. Fuel-fired heaters on trucks can leak exhaust ethylene into floral cargo areas during transport if heat exchangers are cracked.

Microorganisms - Rotting flowers, foliage, fruits and vegetables are perfect media for fungus and bacteria to grow and thrive. There microorganisms are capable of producing large amounts of ethylene. This problem is minimized by practic-ing proper sanitation on a routine basis, in cooler, work areas, and also floral buckets. Discard trimmed leaves, stem cut-tings or any decaying plant matter as soon as possible.

Produce - As fruit baskets are becoming more popular in the floral industry, it is important to be aware of the greater riskof ethylene damage to floral while stored or shipped with high ethylene producing fruit. These include: apples, peaches, pears, bananas, and kiwifruit. While oranges and other citrus are low producers, they are susceptible to fungal growth. Even if a fruit basket is shrink wrapped, ethylene can pass through the pores of the poly films used. Fruit should ideally be isolated from floral products.

Tobacco Smoke - When many smokers are in an enclosed area, studies have shown that there can be a significant build up of ethylene gas over several hours. Do not smoke around horticultural products, or be certain that there is plentyof ventilation.

ELIMINATING ETHYLENE

Even with the above measures there will still be ethylene present, and even small amounts can cause significant and irreversible damage. Direct removal is done with ethylene scrubbers. When strategically placed in the air stream, as air passes through them, our Air Repair™ blankets or tubes act as filters. Ethylene gas present in the air is oxidized by the potassium permanganate beads in the filters, so clean air is being recirculated. Air Repair™ filters need to be replaced on a regular basis, depending on levels of ethylene present.

- 3 -

DeltaTRAK, Inc / P.O. Box 398 / Pleasanton, CA 94566 1-800-962-6776 Fax: 925-249-2251 www.deltatrak.com

Page 109: Quality Solutions from DeltaTRAK - Cynotex · Quality Solutions from DeltaTRAK ... Analog Brix Meter ... . 65 FlashLink VU In-Transit Data Logger, #20741

107

PrimePro EAP, #19030 - #19032

Ethylene Adsorption Packaging (EAP)

Extends shelf life and maintains quality

Linear low density polyethylene (LLDPE) plastic fi lm

Proprietary additive for ethylene adsorption

Anti-fog additive reduces water droplets

No special equipment required for packaging process

No gas needed to replace air under pallet cover

11G1

PrimePro® EAP

Model 19032Sheets

Product Pallet Cover Carton Liner * Sheet *

Model No.: 19030 19031 19032

Dimensions 50in x 96in x42in(127cm x 244cm x 107cm)

24in x 16in x 8in(60cm x 40cm x20cm)

24in x 52in(61cm x 132cm)

Gauge 1 mil (25 micron) 1 mil (25 micron) 1 mil (25 micron)

Quantity 50 Bags per roll 400 Bags per carton 1400 Sheets per carton

Notes: PrimePro EAP meets the standards for food contact use as stated in US FDA CFR 177:1520 (c) 2.1. In compliance with European Union and member state legislation for food contact materials

Model 19030Pallet Covers