Chair Base 1 - 2 - On/Off Switch with LED Indicator Fuse Holder Water Tank Pressure Valve 1 - 2 - 1º - Check if the equipment is properly installed in accordance with the instructions in chapter 6 of the User Manual Dental Line; 2º - Turn On the air compressor that supplies the equipment; 3º - Open the main water supply valve of the equipment; 4º - Turn On the equipment's power circuit breaker. Before Turning On the Equipment: 1º - Turn On the On/Off switch (F02-1); 2º - Activate the "Seat Up" command (F03-6) on the base chair until the seat reaches its maximum height limit; 3º - Close the pressure valve (F01-2); 4º - Remove the water tank (F01-1) and make sure it filled with water. If necessary, fill it with drinkable water up to the limit indicated in tank and reattach it again. If you wish, to place prophylactic products (low concentration); 5 º - Open the pressure valve (F01-2) and check if the water tank (F01-1) is well attached and free of leaks; 6º - Before starting the use equipment, verify the operation of all instruments and commands available and perform the cleaning and sterilization of the instruments (chapter 7 of the User Manual Dental Line - Cleaning and Disinfection). Ligando o equipamento: Page 01 - 5409198 - R02 Quality Quick Operation Guide - Description of Parts and Controls of Equipment Delivery System 10 Commands 1 2 Before using the equipment, please read the User Manual Dental Line carefully. The purpose of this guide is to identify commands, parts, and instruments that may be available to the equipment, including optional items. This guide does not define the equipment configuration that may vary according to the customer's request. In case of loss of the User Manual and/or Operation Guide, please contact us by e-mail informing the serial number of your equipment. [email protected] 2 1 Operating Lights Control Knob Control Rod Sensor 1 - 2 - 3 - 1° - To activate the operating light press the On/Off operating light command on the command panel (F15-9/F16-9/F17-9) or on the chair base (F03-7), this action also enables the sensor (F05- 3/F07-3) and control knob/rod (F05-1/F07-2); 2º - To change the light intensity of the Concept LED (F04) hold the control knob (F03-7/F15-9/F16-9/F17-9) pressed for more than 2 seconds; 3° - To turn On/Off the Concept Plus LED (F06) and Premium (F05) move your hand in front of the sensor (F05-3/F07-3) approximately 5 cm away or hold the control rod (F07-2) in the case of the Concept Plus LED or turn the control knob (F05-1) in the case of the Premium LED; 4° - To change the light intensity of the Concep Plus LED (F06) and Premium LED (F05), keep your hand in front of the sensor (F05-3/F07-3) or hold the control rod (F07-2) in the Concept Plus LED or turn the control knob (F05-1) in the case of the Premium LED. Concept LED Premium LED 3 2 1 3 Concept LED Plus F04 F05 F06 F07 Water Unit Spittoon Bowl Control Cup Filler Control Water Unit Needle Valve 1 - 2 - 3 - 1º - To control the flow of water for cup filler (F08-2) and spittoon bowl (F08-1), the water unit provides a needle valve (F08-3). Instruments Holder Vacuum Pump Adaptor Venturi Saliva Ejector 1 - 2 - 3 - Assistant Module F01 F02 F08 7 8 1 2 3 4 5 9 6 F03 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - Zero Position Work Position Backrest Up ( ) Seat Down ( ) Backrest Down ( ) Seat Up ( ) On/Off Operating Light Spittoon Bowl Flush On/Off Vórtice Saliva Ejector Progressive/Activation Pedal 1 3 2 2 1 F09 3 Observe the Scheduled Review system for your equipment - Chapter 12 of the User Manual Dental Line. - Equipments made to last! Q U A L I T Y Q U A L I T Y

Upload: others

Post on 03-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Quality Quick Operation Guide - Description of Parts and ...€¦ · sterilization of the instruments (chapter 7 of the User Manual Dental Line - Cleaning and Disinfection). Ligando

Ch

air B

ase

1 -2 -

On/Off Switch with LED IndicatorFuse Holder

Water TankPressure Valve

1 -2 -

1º - Check if the equipment is properly installed in accordance with the instructions in chapter 6 of the UserManual Dental Line;

2º - Turn On the air compressor that supplies the equipment;

3º - Open the main water supply valve of the equipment;

4º - Turn On the equipment's power circuit breaker.

Before Turning On the Equipment:

1º - Turn On the On/Off switch (F02-1);

2º - Activate the "Seat Up" command (F03-6) on the base chair until the seat reaches its maximum height limit;

3º - Close the pressure valve (F01-2);

4º - Remove the water tank (F01-1) and make sure it filled with water. If necessary, fill it with drinkable water up to the limit indicated in tank and reattach it again. If you wish, to place prophylactic products (low concentration);

5 º - Open the pressure valve (F01-2) and check if the water tank (F01-1) is well attached and free of leaks;

6º - Before starting the use equipment, verify the operation of all instruments and commands available and perform the cleaning and sterilization of the instruments (chapter 7 of the User Manual Dental Line - Cleaning and Disinfection).

Ligando o equipamento:

Page 01 - 5409198 - R02

Quality Quick Operation Guide - Description of Parts and Controls of Equipment

De

livery S

ystem

10

Co

mm

an

ds

1

2

Before using the equipment, please read the User Manual Dental Line carefully.

The purpose of this guide is to identify commands, parts, and instruments that may be available to the equipment, including optional items.This guide does not define the equipment configuration that may vary according to the customer's request.

In case of loss of the User Manual and/or Operation Guide, please contact us by e-mail informing the serial number of your [email protected]

2

1

Op

era

ting

Lig

hts

Control KnobControl RodSensor

1 -2 -3 -

1° - To activate the operating light press the On/Off operating lightcommand on the command panel (F15-9/F16-9/F17-9) or on the chair base (F03-7), this action also enables the sensor (F05-3/F07-3) and control knob/rod (F05-1/F07-2);

2º - To change the light intensity of the Concept LED (F04) hold the control knob (F03-7/F15-9/F16-9/F17-9) pressed for more than 2 seconds;

3° - To turn On/Off the Concept Plus LED (F06) and Premium (F05) move your hand in front of the sensor (F05-3/F07-3) approximately 5 cm away or hold the control rod (F07-2) in the case of the Concept Plus LED or turn the control knob (F05-1) in the case of the Premium LED;

4° - To change the light intensity of the Concep Plus LED (F06) and Premium LED (F05), keep your hand in front of the sensor (F05-3/F07-3) or hold the control rod (F07-2) in the Concept Plus LED or turn the control knob (F05-1) in the case of the Premium LED.

Concept LED Premium LED

3

2

1 3

Concept LED PlusF04 F05

F06 F07

Wa

ter U

nit

Spittoon Bowl ControlCup Filler ControlWater Unit Needle Valve

1 -2 -3 -

1º - To control the flow of water for cupfiller (F08-2) and spittoon bowl (F08-1),the water unit provides a needle valve(F08-3).

Instruments HolderVacuum Pump AdaptorVenturi Saliva Ejector

1 -2 -3 -

Assista

nt M

od

ule

F01

F02

F08

78

1

2

3

4

5

9 6F03

1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 -10 -

Zero PositionWork PositionBackrest Up ( )Seat Down ( )Backrest Down ( )Seat Up ( )On/Off Operating LightSpittoon Bowl FlushOn/Off Vórtice Saliva EjectorProgressive/Activation Pedal

13

2

2

1F093

Observe the Scheduled Review system for your equipment - Chapter 12 of the User Manual Dental Line. - Equipments made to last!

QU

ALIT

Y

QU

ALIT

Y

Page 2: Quality Quick Operation Guide - Description of Parts and ...€¦ · sterilization of the instruments (chapter 7 of the User Manual Dental Line - Cleaning and Disinfection). Ligando

109

1 4 5 6 7 83

1312

4321

5

6 9

7

8

5

10

6

8

11

214

Co

mm

an

d P

an

els

Wo

rkin

g Ta

ble

s

Only move the working table pressing the pneumatic brake valve or hold the capacitive handle. See section 5.4 of Quality Operation Guide.

The Quality working tables canpresent some configurations ofcommand panels, varying accordingto available instruments.

Quality Cross Flex

Quality Working Table Blue Touch Panel Models

Instru

me

nts P

an

el

1

5

2

9874

10

12

11

3 6

Blue Touch Panel - X-Ray Viewer

13

14

22 33 441

1 2 3 4 14

6

5

13

8

7

9

14

13

Electrical Micromotor Speed ControlElectrical Micromotor Direction ControlScaler Power Control and General-Perio/Endo Function SelectorScaler Water ControlOn/Off Thermo Comfort System LEDOptical Fiber Water ControlBrushless Micromotor Water ControlPneumatic Brake Valve

1 -2 - 3 - 4 - 5 -6 -7 -8 -

F11

F17 F18

F10

E

G P

Min Máx

1

2 3

4

E

Min Máx

3

2

1

4 6

F13

F16

F19

Scaler with LED LightElectrical MicromotorProphylaxis System with Bicarbonate JetInstruments Control PanelCapacitive HandleCoupling for High-speed HandpieceCoupling for Optical Fiber Handpiece3-Way SyringeSodium Bicarbonate ReservoirCommand PanelStainless Steel TrayOn/Off Optical Fiber/Air Jet SystemOn/Off Thermo Comfort System

1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 -10 -11 -12 -13 -

11

F15

Command Panel - Brushless Electrical Micromotor

20:1

17

20

15 16

18

19F20

P S

200000

High Speed

rpm

ON /OFF

P1

F :1 1 10S

16

21

22

23

25

24

18

F21

Seat Up/Position 1Backrest Up/Position 2Seat Down/Position 3Backrest DownWork PositionZero PositionSpittoon Bowl FlushCup FillerOn/Off Operating LightOn/Off Optical Fiber LightOn/Off Air Jet SystemOn/Off Thermo Comfort System

1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 -10 -11 -12 -

X-Ray ViewerOn/Off X-Ray ViewerReverseDisplayTransmission IndicatorsAdjustmentsSelect MemoryProgramDirectionGear RatioSettingManual Start

13 -14 -15 -16 -17 -18 -19 -20 -21 -22 -23 -24 -25 -

Page 02 - 5409198 - R02

Quality Quick Operation Guide - Description of Parts and Controls of Equipment

Observe the Scheduled Review system for your equipment - Chapter 12 of the User Manual Dental Line. - Equipments made to last!

QU

ALIT

Y

QU

ALIT

Y

Hot Water

1 3

2

F12

5

64

7

8F14

Page 3: Quality Quick Operation Guide - Description of Parts and ...€¦ · sterilization of the instruments (chapter 7 of the User Manual Dental Line - Cleaning and Disinfection). Ligando

Pa

ne

l Elé

ctric

o

1 -2 -

Interruptor On/Off con LED Indicador Portafusibles

Tanque de AguaVálvula de Presurización

1 -2 -

1º - Verifique si el equipo está instalado de acuerdo con las instrucciones del capítulo 6 del Manual del Usuario Línea Odontológica;

2º - Encienda el compresor que suministra aire al equipo;

3º - Abra la llave principal de suministro de agua para elEquipo;

4º - Encienda el interruptor de suministro eléctrico para elequipo.

Antes de encender el equipo:

1º - Encienda el Interruptor On/Off (F02-1), su LED indicador se encenderá;

2º - Accione el comando "Sube Asiento" (F03-6) en la base del sillón hasta que el sillón llegue a su límite de altura;

3º - Cierra la válvula de presurización (F01-2);

4º - Remueva el tanque de agua (F01-1) y asegúrese de que esté completo con agua. Si es necesario, llénelo con agua potable filtrada hasta el límite indicado en el tanque y acóplalo nuevamente. Si desea, colocar productos profilácticos (baja concentración);

5º - Abra la válvula de presión (F01-2) y verifica si el tanque de agua (F01-1) está bien acoplado, sin fugas;

6º - Antes de empezar la utilización del equipo, verifica la operación de todos los instrumentos y comandos disponibles y realiza la limpieza y esterilización de los instrumentos (capítulo 7 del Manual del Usuario Línea Odontológica - Limpieza y Desinfección).

Encendiendo el Equipo

Pag. 01 - 5409198 - R02

Guía Rápida de Operación Quality - Descripción de Partes y Controles del Equipo

Pla

tafo

rma

10

Co

ma

nd

os

1

2

Antes de utilizar el equipo, por favor lea el Manual del Usuario Línea Odontológica cuidadosamente.

El propósito de esta guía es identificar los comandos, piezas e instrumentos que pueden estar disponibles para el equipo, incluidos los elementos opcionales.Esta guía no define la configuración del equipo que puede variar según la solicitud del cliente.

En caso de pérdida del Manual del Usuario y/o el Guía de Operación, contáctenos por correo electrónico informando el número serial de su [email protected]

2

1

mp

ara

s

Botón de ControlPalanca de Control Sensor

1 -2 -3 -

1° - Para activar la lámpara, presione el comando de encendido/apagado de la lámpara en los paneles de comandos (F15-9/F16-9/F17-9/F18-9) o en el pedal (F03-7), esta acción también habilita el sensor (F05-3/F07-3) y el botón/palanca de control (F05-1/F07-2);

2º - Para cambiar la intensidad de iluminación del Concept LED (F04), mantenga presionado el comando (F03-7/F15-9/F16-9/F17-9/F18-9) durante más de 2 segundos;

3° - Para encender/apagar el Concept Plus LED (F06) y Premium LED (F05) mueva su mano delante del sensor (F05-3/F07-3) a aproximadamente 5 cm de distancia o sostenga la palanca de control (F07-2 ) en el caso del Concept Plus LED o gire el botón de control (F05-1) en el caso del Premium LED;

4° - Para cambiar la intensidad de iluminación del Concept Plus LED (F06) y el Premium LED (F05), mantenga la mano delante del sensor (F05-3/F07-3) o sostenga la palanca de control (F07-2) en el Concept Plus LED o gire el botón de ontrol (F05-1) en el caso del Premium LED.

Concept LED Premium LED

3

2

1 3

Concept LED PlusF04 F05

F06 F07

Un

ida

d d

e A

gu

a Comando de Agua en la Taza

Comando de Agua en el Llena Vasos Llave de Agua

1 -2 -3 -

1º - Para controlar el flujo de agua para llena vasos (F08-2) y taza (F08-1), utilizar la llave de agua (F08-3).

Soporte de InstrumentosEyetor de Bomba de VacíoEyector Venturi

1 -2 -3 -

du

lo p

ara

Asiste

nte

F01

F02

F08

78

1

2

3

4

5

9 6F03

1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 -10 -

Posición CeroPosición de TrabajoSube Respaldo ( )Baja Asiento ( )Baja Respaldo ( )Sube Asiento ( )On/Off LámparaComando de Agua en la TazaOn/Off Eyector VórticePedal de Propulsión/Activación

13

2

2

1F093

QU

ALIT

Y

QU

ALIT

Y

Tenga en cuenta el Sistema de Revisión para su equipo - Capítulo 12 del Manual del Usuario - Línea Odontológica. - Equipos hechos para durar

Page 4: Quality Quick Operation Guide - Description of Parts and ...€¦ · sterilization of the instruments (chapter 7 of the User Manual Dental Line - Cleaning and Disinfection). Ligando

109

1 4 5 6 7 83

1312

4321

5

6 9

7

8

5

10

6

8

11

214

Pa

ne

les d

e C

om

an

do

Me

sas O

do

nto

lóg

ica

s

Mover la mesa solamente presionando la válvula del freno neumático o sostenga la manija capacitiva. Consulte la sección 5.4 de la Guía de Operación Quality.

Las mesas odontológicas puedenpresentar distintas configuraciónesdel panel de comando, de acuerdoCon los instrumentos disponibles.

Quality Cross Flex

Mesa Quality Paneles de Comando Blue Touch

Pa

ne

l de

Instru

me

nto

s

1

5

2

9874

10

12

11

3 6

Paneles de Comandos Blue Touch - Negatoscopio

13

14

22 33 441

1 2 3 4 14

6

5

13

8

7

9

14

13

Control de Velocidad para Micromotor EléctricoInversor de Rotación del Micromotor EléctricoPotência del Ultrasonido y Selector de Funciones - General-Perio/EndoControl de Agua del UltrasonidoLED del Sistema Thermo ComfortControl de Agua de la Fibra ÓpticaControl de Agua del Micromotor BrushlessVálvula del Freno Neumático

1 -2 - 3 - 4 - 5 -6 -7 -8 -

F11

F17 F18

F10

E

G P

Min Máx

1

2 3

4

E

Min Máx

3

2

1

4 6

F13

F16

F19

Ultrasonido con LEDMicromotor EléctricoSistema de Profilaxis con Chorro de BicarbonatoPanel de Control de InstrumentosManija CapacitivaAcople para Alta RotaciónAcople para Fibra ÓpticaJeringa TripleTanque de BicarbonatoPanel de ComandoBandeja de Acero InoxidableOn/Off Fibra Optica/Sistema Air JetOn/Off Sistema Thermo Comfort

1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 -10 -11 -12 -13 -

11

F15

Panel de Comando - Micromotor Eléctrico Brushless

20:1

17

20

15 16

18

19F20

P S

200000

High Speed

rpm

ON /OFF

P1

F :1 1 10S

16

21

22

23

25

24

18

F21

Sube Asiento/Posición 1Sube Respaldo/Posición 2Baja Asiento/Posición 3Baja RespaldoPosición de TrabajoPosición CeroAgua en la TazaAgua del Llena VasosOn/Off de la LámparaOn/Off Luz de la Fibra ÓpticaOn/Off Sistema Air JetOn/Off Sistema Thermo Comfort

1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 -10 -11 -12 -

NegatoscopioOn/Off NegatoscopioReverse (Tecla de Reverso)DisplayIndicadores de SelecciónTeclas de AjusteSelect (Tecla de Selección)Memory (Teclas de Memoria)Program (Programa)Direction (Dirección)Gear Ratio (Relación de Transmisión)Setting (Sistema)Manual Start (Inicio Manual)

13 -14 -15 -16 -17 -18 -19 -20 -21 -22 -23 -24 -25 -

QU

ALIT

Y

QU

ALIT

Y

Hot Water

1 3

2

F12

5

64

7

8F14

Guía Rápida de Operación Quality - Descripción de Partes y Controles del Equipo

Tenga en cuenta el Sistema de Revisión para su equipo - Capítulo 12 del Manual del Usuario - Línea Odontológica. - Equipos hechos para durarPag. 02 - 5409198 - R02