is first laminate flooring supplier who sets up its own quality control system. All your concerns on laminate flooring quality will be covered into DQS.
DQSTM
Controls starts BEFORE production.
Checking on papers (Abrasion paper, Decoration paper,Balance paper) 1DQS
TM
Quality Control continues during production.
Hot Pressing 24hrs Acclimation
Plank Cutting 7days Acclimation
DQSTM
Test performs on finished products
Determination of thickness
Using the micrometer, calliper gauge or any other equivalent tool, measure the thickness at a distance of 20
mm from the edges of the surface layer, at points located in each corner and in the middle of each long side
(only four corner points if length < 600 mm)
Dimensions in millimetres
20
l/2
20
2020
DQSTM
Test performs on finished products
Determination of length
Using the appropriate calliper gauge or any other equivalent tool, measure the length of the surface layer
along two lines parallel to the axis of the test specimen, at a distance of 20 mm from the long sides
Dimensions in millimetres
2020 l
DQSTM
Test performs on finished products
Determination of width
Using the appropriate calliper gauge or any other equivalent tool, measure the width , along two lines
parallel to the sides of the surface layer, at a distance of 20 mm from the sides, and in the middle for elements
with a length greater than 600 mm
Dimensions in millimetres
0202
l/2
DQSTM
Test performs on finished products
Place one side of the square against one long side of the surface layer of the element. Using the thickness
gauges, determine the maximum deviation from square q at the small side. Repeat the procedure on the
diagonally opposite corner
maxW
l
q
Determination of squareness
DQSTM
Test performs on finished products
Determination of straightness
s
l
Place the steel ruler against one long side of the surface layer. Using the thickness gauges, determine the
maximum deviation S from the ruler. Measure only the concave or cupped sidemax
DQSTM
Test performs on finished products
Determination of thickness swelling
1 2
Determine the initial thickness of the test specimens perpendicular on the extreme edges at the six points
indicated in Figure G.2. Place the two test specimens in the water bath as illustrated in Figure G.3. Remove
the test specimens after 24 h ± 15 min, and dry them with a towel. Determine the final thickness of the
test specimens perpendicular on the extreme edges at the same six measuring points.
Dimensions in millimetres
50
DQSTM