Takashi Matsushita [email protected] Imperial College T. Matsushita 1 Quality Assurance 16/05/06

Upload: conley

Post on 08-Jan-2016

14 views

Category:

Documents


0 download

DESCRIPTION

Quality Assurance. 16/05/06. Station assembly QA /comb - i. Comb arrived: 9 May Doublet layer arrived: 15 May Length of the scintillating fibre is about 40cm, bit short to play with comb Need to shift doublet layer on vacuum chuck - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Quality Assurance

Takashi Matsushita

[email protected]

Imperial College

T. Matsushita 1

Quality Assurance

16/05/06

Page 2: Quality Assurance

T. Matsushita 2

Station assembly QA /comb - i

Comb arrived: 9 May Doublet layer arrived: 15

May

Length of the scintillating fibre is about 40cm, bit short to play with comb

Need to shift doublet layer on vacuum chuck

For bundling of the fibre, better to cut the fibre to the same length

For the production version, the length of the fibre > 50 cm, will be OK

40cm

Page 3: Quality Assurance

T. Matsushita 3

Station Assembly QA - ii

Comb holder made;16 May

Vacuum tube connector

Comb position adjustable

Scintillating fibres tangle up to comb’s slit and teeth=> Needs cover on top of the comb

Page 4: Quality Assurance

T. Matsushita 4

Vacuum chuck

Vacuum pump switch

Suction on/off switch

Tube attached to vacuum chuck

Vacuum pump is quite noisy;better to move outside of the room to make a worker friendly environment

Page 5: Quality Assurance

T. Matsushita 5

Microscope with CCD

CCD Light controller Stage controller Video text overlay switch CRT

Page 6: Quality Assurance

T. Matsushita 6

Straightness check - i

Unmount vacuum chuck holder;

Be careful to this pin

Put holder on stage

Fix the holder

x

y

Page 7: Quality Assurance

T. Matsushita 7

Straightness check - ii

Align the vacuum chuck with alignment pinuntil the fibres on the CRT and the crosshairs on the CRT match

Then scan across the fibreto check deviation from straightness

Stage controller boot sequence;1. Double click

D:/Microscan/Microscan.ht2. Open MicroScan.txt on desktop3. Copy texts to hyper terminal4. Type “man()” then press return;

a text “UNDER MANUAL CONTROL” should appear onLCD of SPECTROLAB MICROSCAN

Page 8: Quality Assurance

T. Matsushita 8

Todo

Tools and parts scattered around in the room;need to tidy the room for efficient work

PC for stage controller too slow;Windows XP running on Pentium 200MHz with 128MB memory; ridiculous10 minutes to boot; 10 minutes to shut down

Finish straightness check

Try bundling with comb