© Copyright 2016 KE2 Therm Solutions, Inc. Washington, Missouri 63090 Q.1.21 March 2016 10’, 25’, & 40’ Wire Harness (10’ pn 20736, 25’ pn 20670; 40’ pn 20737) Simplified Wiring for the KE2 Evaporator Efficiency, KE2 Controlled Environment, KE2 Evap for Rack Efficiency, and the KE2 Adaptive Control Introduction The wire harness simplifies installation of many KE2 Therm con- trollers by providing color coded wires with connectors that correspond to the controller’s inputs. This speeds installation by eliminating on site preparation of wires, wire labeling, and ad- ditionally reduces the need to stock multiple colors and gauges of wires. The stranded wires used in the harness are flexible, making them easier to pull and route, and the wire harness is kept from Power black (L1) 16 AWG stripped & retained white (L2 or neutral) 16 AWG stripped & retained Ground green 16 AWG stripped & retained Defrost Heat orange w. black stripe 12 AWG flag connectors black w. orange stripe (L1) 12 AWG flag connectors Fans blue w. black stripe 14 AWG flag connectors black w. blue stripe (L1) 14 AWG flag connectors LLS/Compressor Yellow w. black stripe 16 AWG stripped & retained black w. yellow stripe (L1) 16 AWG stripped & retained tangling by a cable tie at each end. The wires are 10’, 25’ or 40’ from cable tie to cable tie, making the overall harness approxi- mately a foot longer. The mounting box, shown on the reverse side of this bulletin, also helps simplify installation for the KE2 Evaporator Efficiency, KE2 Controlled Environment, and KE2 Evap for Rack Efficiency controllers. Function Color Gauge Wire Ends Power black with white stripe L1 16 AWG stripped and retained Power white with red stripe L2/neutral 16 AWG stripped and retained Ground green 16 AWG stripped and retained Defrost Heat orange with black stripe 12 AWG flag connectors Defrost Heat black with orange stripe L1 12 AWG flag connectors Fans blue with black stripe 14 AWG flag connectors Fans black with blue stripe L1 14 AWG flag connectors LLS/Compressor yellow with black stripe 16 AWG stripped and retained LLS/Compressor black with yellow stripe L1 16 AWG stripped and retained

Upload: others

Post on 19-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Q.121 arch 216 10 , 25 , & 40 Wire Harness · Q.121 arch 216 10 , 25 , & 40 Wire Harness (10 pn 20736, 25 pn 20670; 40 pn 20737) 6LPe rng or te aorator cenc ontroe nronent a or ac

© Copyright 2016 KE2 Therm Solutions, Inc. Washington, Missouri 63090

Q.1.21 March 2016

10’, 25’, & 40’ Wire Harness (10’ pn 20736, 25’ pn 20670; 40’ pn 20737)Simplified Wiring for the KE2 Evaporator Efficiency, KE2 Controlled Environment, KE2 Evap for Rack Efficiency, and the KE2 Adaptive Control

Introduction The wire harness simplifies installation of many KE2 Therm con-trollers by providing color coded wires with connectors that correspond to the controller’s inputs. This speeds installation by eliminating on site preparation of wires, wire labeling, and ad-ditionally reduces the need to stock multiple colors and gauges of wires.

The stranded wires used in the harness are flexible, making them easier to pull and route, and the wire harness is kept from

Power black (L1) 16 AWG stripped & retained

white (L2 or neutral) 16 AWG stripped & retainedGroundgreen 16 AWG stripped & retained

Defrost Heatorange w. black stripe 12 AWG �ag connectorsblack w. orange stripe (L1)12 AWG �ag connectors

Fansblue w. black stripe 14 AWG �ag connectors

black w. blue stripe (L1)14 AWG �ag connectors

LLS/CompressorYellow w. black stripe 16 AWG stripped & retained

black w. yellow stripe (L1)16 AWG stripped & retained

tangling by a cable tie at each end. The wires are 10’, 25’ or 40’ from cable tie to cable tie, making the overall harness approxi-mately a foot longer.

The mounting box, shown on the reverse side of this bulletin, also helps simplify installation for the KE2 Evaporator Efficiency, KE2 Controlled Environment, and KE2 Evap for Rack Efficiency controllers.

Function Color Gauge Wire EndsPower black with white stripe L1 16 AWG stripped and retained

Power white with red stripe L2/neutral 16 AWG stripped and retained

Ground green 16 AWG stripped and retained

Defrost Heat orange with black stripe 12 AWG flag connectors

Defrost Heat black with orange stripe L1 12 AWG flag connectors

Fans blue with black stripe 14 AWG flag connectors

Fans black with blue stripe L1 14 AWG flag connectors

LLS/Compressor yellow with black stripe 16 AWG stripped and retained

LLS/Compressor black with yellow stripe L1 16 AWG stripped and retained

Page 2: Q.121 arch 216 10 , 25 , & 40 Wire Harness · Q.121 arch 216 10 , 25 , & 40 Wire Harness (10 pn 20736, 25 pn 20670; 40 pn 20737) 6LPe rng or te aorator cenc ontroe nronent a or ac

© Copyright 2016 KE2 Therm Solutions, Inc. Washington, Missouri 63090Q.1.21 March 2016 supersedes April 2015 and all prior publications.

Q.1.21 March 2016

Mounting Box (pn 20687)for the KE2 Evaporator Efficiency, KE2 Controlled Environment, KE2 Evap for Rack Efficiency

Introduction The mounting box was designed to simplify the installation of our controllers. Constructed of stamped aluminum, it blends into the refrigeration environment, providing a clean appear-ance to the finished install.

Constructed of 40 mil embossed aluminum, the box measures 12.3 x 6.4 x 2.0 inches and includes the necessary hardware to mount the box and controller. When installing the controller, the mounting box provides a stationary location to attach con-duit, allowing the controller to be secured for easy installation and service. The box is sized to accommodate the controller’s

wiring, providing space for the service loops to be stored.

Once the box has been fastened appropriately in the mounting location, the conduit may be attached. The controller can then be securely held with the wiring side facing outward to assist in initial wiring. See Photo B. It is important to find a safe location to store the controller while the high and low voltage connec-tions are made. Once installed, the controller may be orientated in its normal operating position on the 4 mounting screws pro-vided. See Photo A.

Photo A - Left: KE2 Evap installed on a mounting box.

Photo B - Below: When servicing, the controller can be hung by two screws, allow-ing access to wiring, without the controller being supported by the wires. Shown here wired with the 25’ Wire Harness.

KE2 Therm Solutions, Inc. 12 Chamber Drive . Washington, MO 63090

1-888-337-3358 . www.ke2therm.com