  • 17664

    PWi Forging

    Tonnage Monitor

    By Toledo Integrated Systems

    User’s Manual

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    1

    PWi Forging User’s Manual

    Revision: A

    http://www.toledointegratedsystems.com

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    2

    Table of Contents

    11:: Installation ........................................................................................................... 5 Limited Warranty ............................................................................................................................ 5 Features Overview .......................................................................................................................... 6 Specifications .................................................................................................................................. 7 Mounting the PWi Forging – Standard Installation ........................................................................ 9 Mounting the PWi Forging – Flush Mount Option ...................................................................... 10 PWi Forging Components ............................................................................................................. 11 Conduit Hole Selection ................................................................................................................. 12 AC Power Connection and Configuration .................................................................................... 13 DC Power Connection .................................................................................................................. 14 Sensor Input Configuration ........................................................................................................... 15 Load Sensor Connection ............................................................................................................... 16 Sensor Cable Termination ............................................................................................................ 17 Sensors Connection ....................................................................................................................... 18 Analog Output ............................................................................................................................... 19 Probe Input .................................................................................................................................... 20 External Reset Switch Connection ............................................................................................... 22 Serial Port Connection .................................................................................................................. 23 Shutdown Relays .......................................................................................................................... 25 

    22:: Operation .......................................................................................................... 27 User Interface ................................................................................................................................ 27 Operation Mode and Configuration Mode .................................................................................... 28 The Security Code Feature ........................................................................................................... 29 The Low Battery Indicator ............................................................................................................ 30 Replacing the Backup Battery ...................................................................................................... 31 Operation Mode - Overview ......................................................................................................... 32 Operation Mode - Description ...................................................................................................... 33 

    Home Menu ............................................................................................................................... 33 Signature Menu ......................................................................................................................... 35 Setpoint Menu ........................................................................................................................... 39 Alarm Menu .............................................................................................................................. 41 Reverse Menu ............................................................................................................................ 42 Statistics Menu .......................................................................................................................... 43 Job Menu ................................................................................................................................... 45 Station Menu ............................................................................................................................. 46 Security Code Menu (Operation mode) .................................................................................... 47 

    Configuration Mode - Overview ................................................................................................... 50 Configuration Mode - Description ................................................................................................ 51 

    Channel Menu ........................................................................................................................... 51 Decimal Point Menu ................................................................................................................. 52 Capacity Menu .......................................................................................................................... 53 Trigger Menu ............................................................................................................................ 54 

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    3

    Threshold Menu ........................................................................................................................ 55 Learn Menu .............................................................................................................................. 56 Delay Menu .............................................................................................................................. 57 Offset Menu .............................................................................................................................. 58 Mode Menu ............................................................................................................................... 59 E-Stop Menu ............................................................................................................................. 60 Setup Count Menu .................................................................................................................... 61 Address Menu ........................................................................................................................... 62 Baud Rate Menu ....................................................................................................................... 63 Calibration Menu ..................................................................................................................... 64 Security Code Menu (Configuration mode) ............................................................................. 65 

    33:: Calibration Procedure ...................................................................................... 69 44:: Calibration Information Label ........................................................................ 73 55:: Operator’s Guide .............................................................................................. 75 66:: Appendix ............................................................................................................ 77 

    I)  Sensor Installation (Doc# 11080) .......................................................................................... 77 II)  Calibration Sheets (Form# 1224) ....................................................................................... 77 

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    4

    Table of Figures Figure 1.1: Standard Mounting Dimensions .................................................................................... 9 Figure 1.2: Flush Mount Mounting Dimensions ........................................................................... 10 Figure 1.3: PWi Forging Components ........................................................................................... 11 Figure 1.4: Conduit Hole Selection ............................................................................................... 12 Figure 1.5: AC Power Connection and Jumper Settings ............................................................... 13 Figure 1.6: DC Power Connection ................................................................................................. 14 Figure 1.7: Sensor Configuration Jumper Settings ........................................................................ 15 Figure 1.8: Sensor Input Locations ................................................................................................ 16 Figure 1.9: Sensor Cable Stripping ................................................................................................ 17 Figure 1.10: Sensor Wiring .............................................................................................................. 18 Figure 1.11: Analog Output Wiring ................................................................................................. 19 Figure 1.12: Probe Input Wiring ...................................................................................................... 20 Figure 1.13: Probe Timing ............................................................................................................... 21 Figure 1.14: External Reset Switch Wiring ..................................................................................... 22 Figure 1.15: Serial Connection ........................................................................................................ 23 Figure 1.16: RS232 Serial Port Wiring ............................................................................................ 24 Figure 1.17: RS422 Serial Network Wiring .................................................................................... 24 Figure 1.18: Shutdown Relay Wiring .............................................................................................. 25 

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    5

    11:: Installation Limited Warranty

    This unit is warranted by the manufacturer, Toledo Transducers, Inc., to be free of defects in workmanship and materials for one year from date of manufacturer’s shipment. This warranty is limited to repairing or replacing products which manufacturer’s investigation shows were defective at the time of shipment by the manufacturer. All products subject to this warranty must be returned for examination, repair or replacement F.O.B. to: Toledo Transducers, Inc. 6834 Spring Valley Drive Holland, Ohio 43528 The express warranty set forth herein is in lieu of all other warranties, expressed or implied, including without limitation any warranties of merchant-ability or fitness for a particular purpose. All such warranties are hereby disclaimed and excluded by the manufacturer. Repair or replacement of defective products as provided above is the sole and exclusive remedy provided thereunder. The manufacturer shall not be liable for any further loss, damages, or expenses, including incidental or consequential damages, directly or indirectly arising from the sale or use of this product. Any unauthorized repair voids this warranty. There are no warranties that extend beyond those expressly set forth herein.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    6

    Features Overview

    The PWi Forging is a full-featured load monitor that interfaces with load sensors to provide force measurement for press protection and quality control. Unlike traditional tonnage monitors, the PWi Forging monitor is designed for the specific needs of forging applications. The total press load is displayed on high-visibility 7-segment LED displays for up to four forging stations. The user interface consists of six tactile switches and a back-lit LCD graphic display module that provides a user-friendly menu system. The LCD is also used to show deviation, alarm data, settings, and much more.

    FEATURES 4 channel load monitoring 2 shutdown relays (Top-Stop and E-Stop) Reverse load 100 job storage LCD graphic display with back-lighting One RS422 serial port 5-digit LED display for each channel PressNet Software compatible Menu-driven user interface Compact dust-proof enclosure Load signatures

    OPTIONS 24VDC power input Mounting bracket for angle viewing

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    7

    Specifications

    Load Input No. of Channels Four standard (Two optional)

    Sensor Inputs Full bridge strain gage sensors 120 to 1,000 ohms Up to (8) 350 ohm sensors Sensor Excitation Built-in 12VDC @ 300mA max (Short circuit protected) Sensor Input Connections 5-pin .15" pitch Phoenix connector Balance Adjustment 25-turn potentiometer Balance Range +/- 1mV/V of offset Gain Adjustment 25-turn potentiometer Gain Range Low Gain = 50 to 550 times High Gain = 500 to 5,500 times Analog Output 1.25VDC @ Press Capacity Analog Output Connection 9-pin sub-D connector Inaccuracy +/- 1% of full scale max Non-linearity +/- .1% of full scale max Frequency Response Flat DC to 6 KHz Resolution Each channel provides a 5-digit load value in 1024 count resolution Calibration Shunts 1 Meg Ohm, 0.1% resistor

    Job Storage 100 jobs

    Speed Limit Up to 400 SPM with threshold trigger Up to 2,000 SPM with probe trigger

    User Interface Display Back-lit 1.5”x2.75” LCD graphical display (64x128 pixel) (5) LED displays, each consisting of five 7-segment displays

    Keypad Menu-driven keypad consisting of six tactile switches

    Computer Serial Port 1 RS422 (9,600 to 115,200 baud) for PressNet software interface Interface Serial Port 2 & 3 (Optional) RS422 (9,600 to 115,200 baud) for data transfer Probe Input Built-in voltage source (12VDC, 50 mA max) provides power for the probe. It supports NPN or PNP proximity probes, and solid state or dry contact relay. Shutdown Top Stop relay and Mechanical relay with N.O. and N.C. contacts Relays E-Stop relay 8 AMP @ 250VAC or 30VDC

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    8

    Supply Power Requirements 30 Watts max (AC units) 85-132VAC @ 50-60Hz or

    170-264VAC @ 50-60Hz Power Input is jumper selectable Fuse 0.5A for 110VAC input 0.25A for 220VAC input TR5 type, Slow-Blow Supply Power Requirements 24VDC @ 1.25A minimum (DC units) Fuse 1.25A TR5 type, Slow-Blow Data Storage Configuration/Jobs Nonvolatile Data Flash Live data (Counters, peak load) 3V Lithium Battery – Type CR-1/3N Operating 0 to 70 degrees Celsius Temperature Dimensions 8.90" W x 6.88" H x 5.00" D, or

    226mm W x 175mm H x 127mm D

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    9

    Mounting the PWi Forging – Standard Installation

    Note: This section is for mounting standard PWi Forging units. If the flush mount option was purchased, refer to the next section for instructions on mounting the PWi Forging with the flush mount option.

    The PWi Forging is an electronic instrument and must therefore be protected from physical stresses such as shock and vibration. Shock mounts are provided with every standard PWi Forging for this purpose. Failure to use these shock mounts may result in premature failure of the instrument and possibly void your warranty. The PWi Forging may be mounted directly to the press or to an adjacent structure. It should be positioned so that the display is easily read and the instrument is readily accessible. Figure 1.1 below provides the mounting dimensions and demonstrates the proper attachment of the provided shock mounts.

    6.35

    " [16

    1mm

    ]

    8.90" [226mm]

    6.88" [175mm]

    6.88

    " [17

    5 mm

    ]1/4" - 20 STUD

    SHOCK MOUNT ASSEMBLY

    5.00" [127mm]

    +23PEAK-21+22

    RUN ALARM+25-13

    Figure 1.1: Standard Mounting Dimensions

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    10

    Mounting the PWi Forging – Flush Mount Option An optional flush mounted installation is possible as shown in Figure 1.2. The flush mount option has built-in anti-shock components; therefore external shock mounts are not required. As with the standard installation, the flush mount option allows the PWi Forging to be mounted directly to the press or to an adjacent structure. It should be positioned so that the display is easily read and the instrument is readily accessible.

    10.25" [260mm]

    7.64

    " [19

    4mm

    ]

    5.125" [130mm]

    0.31

    " [8m

    m]

    7.02

    " [17

    8mm

    ]

    11.12" [282mm]

    HOLE CUTOUT

    5.125" [130mm]

    .221" DIA. (FOR SIZE #10 SCREW)TYPICAL 6 PLACES

    5.09" [129mm]

    Figure 1.2: Flush Mount Mounting Dimensions

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    11

    PWi Forging Components

    Control Board

    Analog Board

    Figure 1.3: PWi Forging Components

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    12

    Conduit Hole Selection Follow Figure 1.4 to select the proper conduit hole for cabling. The holes are for ½" conduit, but they can be enlarged in the field if a larger fitting is required.

    Serial CommunicationProbe InputExternal Reset SwitchR l

    CONDUIT HOLES

    Load SensorAnalog Sensor

    #1 #2

    BOTTOM VIEWDOOR

    AC LineShutdown Relays

    #3

    Figure 1.4: Conduit Hole Selection

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    13

    AC Power Connection and Configuration (AC unit only) AC power is connected to the PWi Forging’s Analog Board as shown in Figure 1.5. Use Conduit Hole #3 (see Figure 1.4) for the AC Power Wiring. Use the proper fuse as indicated. With the proper jumper settings, the PWi Forging can be powered by either 110 VAC or 220 VAC (Factory set at 110 VAC.) The jumpers are located on the Analog Board as shown below.

    L2 = NEUTRALG = GROUND

    L1 = HOTAC Power Connection

    Fuse: Type TR5 Slow-Blow 500mA@110V 250mA@220V

    A C

    BA

    C B

    220V

    110V

    220VAC = Jumper C Only110VAC = Jumpers A & B

    Figure 1.5: AC Power Connection and Jumper Settings

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    14

    DC Power Connection (DC unit only) DC power is connected to the PWi Forging’s Analog Board as shown in Figure 1.6. The external 24VDC power supply should be rated at 1.25A or higher. Use Conduit Hole #3 (see Figure 1.4) for the DC Power Wiring. Use the proper fuse as indicated. If the power cable has a shield, it can be connected to the Chassis Ground terminal.

    DC Power Connection24V DC

    DC COMCHASSIS GND

    Fuse: Type TR5 Slow-Blow 1.25A

    Figure 1.6: DC Power Connection

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    15

    Sensor Input Configuration Each channel input on the PWi Forging Analog Board can be configured to accept a signal from a strain gage sensor, a 4-20 mA signal, or a 0-10 VDC signal. Balance and gain adjustments are made via two potentiometers for each channel. When configured for tonnage sensor input, gain ranges of X1 and X10 are also selectable. Refer to the illustration below for the location of the balance and gain adjustments and available sensor input configurations.

    TONNAGE

    A B C D EX1 GAIN

    A B C D EX10 GAINTONNAGE

    A B C D E

    A B C D E

    0-10VDC

    4-20mA

    GAIN ADJUSTBALANCEADJUST

    SENSOR CONFIGURATIONJUMPERS (SEE RIGHT)

    Figure 1.7: Sensor Configuration Jumper Settings

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    16

    Load Sensor Connection Refer to Figure 1.8 for the procedures below to connect tonnage sensors properly: 1) Power down the unit. Open the door of the PWi Forging enclosure. 2) Run Load Sensor cables through Conduit Hole #1 (see Figure 1.4), and route cables upward to

    the Analog Board. 3) Prepare the sensor cable for termination as described on page 17. 4) Remove the four 5-pin Phoenix plugs from the analog board and wire each sensor cable as

    described on page 18. 5) The 5-pin phoenix plugs can then be inserted into the corresponding sockets. The load sensor

    cable connections are now complete.

    Analog Board

    Channel 1Left Rear Sensor

    Channel 2Right Rear Sensor

    Channel 3Left Front Sensor

    Channel 4Right Front Sensor

    Figure 1.8: Sensor Input Locations

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    17

    Sensor Cable Termination 1) Strip the sensor cable as shown in the figure below. Be sure not to nick any of the signal

    conductors or cut the braid shield.

    Figure 1.9: Sensor Cable Stripping

    2) Strip approximately ¼" of insulation from each of the four signal conductors. 3) Trim braid shield so that it is ¼" to ½" shorter than the signal wires. Note: If your sensor cable is not double shielded with both foil and a braid, electrical noise may

    affect your output readings.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    18

    Sensors Connection The PWi Forging accepts the signals from Toledo Transducers T-400 sensors as well as other strain gage sensors. Figure 1.10 illustrates the sensor connections. T400 Sensor T400 Sensor

    (Column-mounted sensor) (Pitman-mounted sensor)

    (W)-S

    (R)+S

    (B)(G)+E -E SHL

    RE

    DW

    HIT E

    GR

    EEN

    BLA

    CK

    SH

    IELD

    Figure 1.10: Sensor Wiring

    Tension Compression Force

    Tension connection shown. For compression connections, switch the red and white wires. Make sure the shield braid does not contact the signal wire terminals.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    19

    Analog Output The analog outputs are provided on a 9-pin connector for easy access and for interfacing with other peripherals.

    BOTTOM VIEW

    1 2 3 4 5

    6 7 8 9

    GR

    OU

    ND

    CH

    ANN

    EL 6

    CH

    ANN

    EL 7

    CH

    ANN

    EL 8

    CH

    ANN

    EL 9

    CH

    ANN

    EL 1C

    HAN

    NEL 2

    CH

    ANN

    EL 3C

    HAN

    NEL 4

    Figure 1.11: Analog Output Wiring

    Analog Voltage Output: Swing between 12V 1.25V @ Capacity

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    20

    Probe Input The probe supply voltage (+12VDC) is supplied by the PWi Forging on the Vo terminal. The figure below shows the probe input location on the Analog Board and illustrates different wiring possibilities. Use Conduit Hole #2 (see Figure 1.4) to run the probe wiring. After wiring is completed, you must configure the unit for Probe triggering (see Page 54).

    T-STPE-STPBYP

    CAM1Rx

    CAM2

    Tx

    5Vd12Vd

    Vo

    PROBE INPUT

    G1 1

    NPN2 CAM1 ON = PROBE CLOSED

    CAM1 OFF = PROBE OPEN

    Figure 1.12: Probe Input Wiring

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    21

    The timing of the probe should be such that it turns on just before the machine begins generating a load, typically at (140) and remains on until the load is removed, typically at (240).

    Figure 1.13: Probe Timing

    Trigger Probe

    Load Signal

    140°

    Probe Closed

    Probe Open 240° 140° 240°

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    22

    External Reset Switch Connection Two terminals are provided for connecting an external reset switch. The rating of the switch and wiring can be minimal because they interface with a small signal. Use Conduit Hole #2 (see Figure 1.4) to run the wiring for the reset switch. NOTE – In order to reduce noise that may trigger false reset:

    Use twisted pair wires for the connection. Do not run this pair of wires along with any high voltage or high current cables. Keep the wiring no longer than 12 feet.

    Figure 1.14: External Reset Switch Wiring

    T-STPE-STPBYP

    CAM1Rx

    CAM2

    Tx

    5Vd12Vd

    Vo

    PROBE INPUT

    G1 1

    NPN2 CAM2 ON = EXT. RESET SWITCH CLOSED

    CAM2 OFF = EXT. RESET SWITCH OPEN

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    23

    Serial Port Connection An RS422 serial port is available for interfacing the PWi Forging with a computer running the PressNet software. RS422 allows the implementation of a daisy chain (multi-drop) serial network as a standard feature. The RS422-1 port can be configured for the following baud rates: 9600 38.4k 76.8k 115.2k The figure below details the location of the RS422-1 port. Wiring diagrams can be found on the next page.

    T-STPE-STPBYP

    CAM1Rx

    CAM2

    Tx

    5Vd12Vd

    Rx-Rx+ G Tx+ Tx- SHL

    RS422-1

    FLASHES WHEN DATAIS SENT BY THE MONITOR

    FLASHES WHEN DATAIS RECEIVED BY THE MONITOR

    Figure 1.15: Serial Connection

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    24

    Computer to single PWi Forging monitor wiring:

    Figure 1.16: RS232 Serial Port Wiring Computer to multiple PWi Forging monitors wiring (Networking):

    Figure 1.17: RS422 Serial Network Wiring

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    25

    Shutdown Relays The PWi Forging provides a Top Stop Relay and an E-Stop (Emergency Stop) Relay. When enabled, the E-Stop Relay is used to stop the press immediately in case of a capacity violation. Each relay provides both Normally Open (N.O.) and Normally Close (N.C.) contacts. A toggle switch is provided to manually bypass the shutdown relays, if necessary.

    **CAUTION** Bypassing the shutdown relays is a potentially dangerous situation. The monitor will not shut down the press when this switch is in the bypass position. Equipment can be damaged and personnel may be

    seriously injured without shut down protection. Use Conduit Hole #3 (see Figure 1.4) for the Shutdown Relay Wiring.

    Bypass SwitchNCCOMT-STOP

    SHUTDOWN RELAYS

    NO COMNC NO

    E-STOP

    CAM2T-STP

    BYPE-STP

    5Vd

    Tx

    12Vd

    CAM1Rx

    T-STP ON = TOP STOP RELAY IS OPENE-STP ON = E-STOP RELAY IS OPENBYP ON = SHUTDOWN RELAYS ARE BYPASSED

    BYPASS

    Figure 1.18: Shutdown Relay Wiring

    Shutdown Relay Terminals T-Stop = For use in the Press Top Stop circuitry. E-Stop = For use in the Press Emergency Stop circuitry. Note that using the E-Stop under heavy loads may result in the ram becoming locked at the bottom. Refer to the Configuration Menu section for instructions on enabling the E-Stop relay.

    Relay Contacts NC = Normally Close Contact C = Common NO = Normally Open Contact Ratings: 8 AMP @ 250VAC or 30VDC Type: Mechanical Relay

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    26

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    27

    22:: Operation User Interface The PWi Forging is equipped with an easy to use menu-driven user interface. The six push buttons are used to view and change parameters. The following describes the layout of the LCD screen and the push buttons.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    28

    Operation Mode and Configuration Mode The “Operation Mode” is used in normal operation, and the “Configuration Mode” is for initial setup. Dip-Switch 1 in SW1 is used to select these modes. SW1 is located on the side of the Control Board which is mounted on the inside of the door. To select the Operation Mode Set Dip-Switch 1 to up position To select the Configuration Mode Set Dip-Switch 1 to down position

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    29

    The Security Code Feature When it is enabled, the security code feature restricts unauthorized personnel from making changes while in the Operation mode. It requires the entry of a 4-digit code before performing the following functions:

    Changing the mode (Run/Setup/Learn) Changing setpoints (High, Low, and Reverse) Resetting tonnage alarms Clearing statistics Changing jobs

    As a reminder of the current security status, a lock indicator appears at the top of the LCD display when a security code has not been entered.

    To manage the security code functions, there is a Security Code menu on both the Operation mode and the Configuration mode. Each Security Code menu has different functions. Security Code menu functions for the Operation mode:

    Locking and unlocking the security code. Security Code menu functions for the Configuration mode: Enabling and disabling the security code feature. Changing the 4-digit security code. Resetting the security code to its default.

    Refer to the Operation mode and Configuration mode sections for more details.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    30

    The Low Battery Indicator All critical settings, including system configuration (Capacities, threshold, etc.) and job-related setpoints are stored in nonvolatile flash memory to prevent data loss. However, some non-critical information, including alarm counts, statistics, and live load values, are stored in battery-backed memory. When the battery’s voltage becomes low, a low battery indicator appears on the LCD display on the Home menu.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    31

    Replacing the Backup Battery The backup battery is a 3V Lithium, type CR-1/3N and is commonly sold at most electronics retailers, including RadioShack®. It is located on the Control Board, which is mounted on the inside of the unit’s door. To replace the battery:

    1) Remove power from the PWi Forging unit. 2) Open the enclosure door and locate the Control Board. It is the board mounted on the door. 3) Remove the (6) screws that secure the cover plate to the Control Board. Place the screws

    and the cover plate aside. 4) Locate the battery. Refer to the following diagram.

    PWi Forging Control Board

    5) Remove the old battery from its socket. 6) Insert the new battery. Note the battery polarity printed on the circuit board. 7) Reinstall the cover plate using the (6) screws that were removed in step 3. 8) Close the enclosure door. 9) Apply power.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    32

    Operation Mode - Overview

    To view other menus

    Push or until the desired menu is shown. To return to the Home menu

    From any menu, push to return to the Home menu. The home symbol on the bottom left corner of the display indicates that the current menu is home.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    33

    Operation Mode - Description Home Menu

    The Home menu displays the current peak load and the variation from the benchmark load, as well as the current station number. Setup and Learn mode can be enabled from this menu and the alarm and bypass status can be viewed. If the unit is configured for resolver triggering, the position is displayed here, as well.

    About the displays

    The (4) outer 7-Segment displays show the total peak load for stations 1-4. As the press cycles and the peak values update, the last station indicator (a dot in the upper left corner of the display) moves to the last station in the sequence that was updated. The center 7-Segment display shows the current/next forming station in the sequence. The LCD screen in the center shows the % variation of the current peak load from the learned benchmark load. Each % variation value on the LCD corresponds to one of the stations. For example, the upper-left % variation value corresponds to station 1, the upper-right value corresponds to station 2, etc.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    34

    About the operating modes The operating mode determines how the monitor reacts to the load. Run mode is used for production. All setpoint alarms are active in Run mode. Setup mode is used for die setup. Only capacity limits are active in Setup mode. Learn mode is used to teach the monitor new alarm setpoints. After the unit is

    placed in Learn mode, the next cycle through the stations is used to generate a new benchmark and new high and low setpoints. The monitor then switches to Run mode to continue production.

    To change the operating mode

    1) Push or until the desired mode (RUN, SETUP or LRN) is shown.

    2) Push to accept the change, or push to cancel the change.

    Note: When Setup mode is enabled, the capacity is displayed in place of the % variation. This is a reminder that only capacity limits are active in Setup mode.

    Notes: The figure above illustrates a four-station configuration. If less than four stations

    are configured, the unused stations will remain blank.

    The number of stations required can be changed from the Station Menu, which is covered later in this section.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    35

    Signature Menu

    The Signature menu displays the load signature for the current stroke for analysis and troubleshooting purposes.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    36

    Signature Detail for Probe or Threshold Trigger

    Signature Detail for Resolver Trigger

    To view each corner’s signature

    The corners are represented graphically by four quadrants on the signature menu which correspond to the press corners. For example, in the signature detail above, the upper-left quadrant is filled in while the remaining three quadrants are empty. This indicates that the Left Rear corner is currently displayed. If all four quadrants are filled in, the Total is currently displayed. To select other corners:

    1) If the signature is not paused, push or until the desired corner is shown.

    2) If the signature is paused, push or until the desired corner is shown. As each corner is selected, the quadrant symbols on the menu will change to indicate the current corner.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    37

    To pause and resume the signature updating 1) While the right menu is showing PAUSE:

    Push to stop the signature updating. The right menu now changes to BACK. In this state, the press can continue to run but the signatures will not update. Also, notice that the corner selection menu option has shifted from the center menu to the left menu

    position. While the signature is paused, the and buttons are used to cycle through each of the corners.

    2) While the right menu is showing BACK:

    Push again to resume the signature updating.

    Signature Updating Signature Paused

    To save and load signatures

    1) While the signature is paused and the center menu is showing ANLYZ:

    Push or to access the signature analysis tools. The center menu is now selected and the right menu now changes to APPY.

    With the center menu showing MEM, push to access the various memory options.

    2) To save the current signature:

    Push or to cycle through the memory options until SAVE1 or SAVE2 is selected.

    Push to save the current signature to the corresponding memory location.

    3) To load a previously saved signature:

    Push or to cycle through the memory options until LOAD1 or LOAD2 is selected.

    Push to load the signature. While the signature is being viewed, the current signature number is shown at the top left corner of the display and the following options are available:

    Push or to cycle through the corners, or

    Push or to select the Cursor tool for point-by-point analysis, or

    Push to close the signature and resume signature updating.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    38

    To analyze a signature using the Cursor tool 1) While the signature is paused and the center menu is showing ANLYZ:

    Push or to access the signature analysis tools. The center menu is now selected and the right menu now changes to APPY.

    With the center menu showing CUR, push to turn on the Cursor tool.

    2) To view load signature details when using probe or threshold triggering:

    Push or to increase the time value in the center menu and move the cursor along the load signature. As the cursor moves, the corner displays update with the load for the selected point on the curve.

    Push or to cycle through the corners, or

    Push to close the signature and resume signature updating.

    3) To view load signature details when using resolver triggering:

    Push or to increase the press angle value in the center menu and move the cursor along the load signature. As the cursor moves, the corner displays update with the load for the selected point on the curve.

    Push to toggle the cursor between the load signature and the CCM press curve. When the cursor is on the CCM press curve, the corner displays provide the load for the press curve at the selected position.

    Push or to cycle through the corners, or

    Push to close the signature and resume signature updating.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    39

    Setpoint Menu

    The Setpoint menu displays information for the various types of setpoints and allows each station’s setpoint value to be adjusted. Other information, such as Corner Tonnage Distribution, Capacity, and Benchmark values, can be viewed.

    To view setpoints

    1) Push or until the desired setpoint is shown. 2) Setpoint values are shown in the associated stations.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    40

    To change setpoints

    1) Push to enter change mode. Station 1 is then selected.

    2) Push to select the desired station.

    3) Push or to change the value, or

    Push or to change in a larger increment.

    4) Push to accept the change (the next station will be selected), or push to cancel the change.

    5) Repeat from Step 2 to make changes on other stations.

    6) Push to exit change mode. Note: To bypass a station’s setpoint, change the station’s setpoint % to zero. For example, to disable reverse alarms for station 4, change the REV-% for station 4 to zero.

    To view corner tonnage distribution 1) Push or until the center menu shows CORNR. 2) The peak tonnage values for each channel are shown in the associated corners of the

    LCD, with the total displayed in the center.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    41

    Alarm Menu

    The Alarm menu displays detailed alarm information for each of the stations. If there is an active alarm, it can be reset from this menu.

    To view the alarm list Push or to see each alarm if more than one type of alarm has occurred. If an alarm is active, its associated station load value will flash.

    To reset an alarm

    Push to reset all alarms.

    Notes: Resetting an alarm will automatically reset the station sequence.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    42

    Reverse Menu

    The Reverse menu displays the current reverse load data for each station.

    To view Reverse Load Reverse load values are shown in the associated stations and the Reverse load as a percentage of capacity is shown on the LCD display.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    43

    Statistics Menu

    The Statistics menu displays historical load information for the current job. Various data, such as last alarm, highest load, number of high alarms, etc., can be viewed and reset. The statistics are automatically reset when a job is loaded.

    To view statistics

    1) Push or until the desired statistic is shown. 2) Statistics values are shown in the associated stations.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    44

    To clear individual statistics 1) Push or until the desired statistic is shown.

    2) Push to enter clear mode. All stations are then selected and the cleared statistics values for each station are shown.

    3) Push to accept the clear, or push to cancel the clear.

    To clear all statistics 1) Push or until “ALL” is shown.

    2) Push to enter clear mode. All stations are then selected and the cleared statistics values for each station are shown.

    3) Push to accept the clear, or push to cancel the clear.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    45

    Job Menu

    Jobs provide a convenient way to save and recall the settings associated with a particular part. Setpoints and benchmark data can be saved to a particular job number and recalled later when needed. The Job menu displays the active job number and allows the user to change to a previously created job or create a new job.

    To change the Job Number

    1) Push to enter change mode. Current job number is then selected.

    2) Push or to change the setting.

    3) Push to accept the change, or push to cancel the change.

    Notes: Up to 100 jobs (0-99) can be stored and recalled. When a previously unused job number is selected, a new job is created. When this

    happens, the setpoints from Job #0 are used as a template.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    46

    Station Menu

    The PWi Forging monitor supports up to four forming stations. If a job calls for less than this, the number of stations can be changed in the Station menu.

    To change the number of Stations displayed

    1) Push to enter change mode. Current number of stations is then selected.

    2) Push or to change the setting.

    3) Push to accept the change, or push to cancel the change.

    Notes: When less than four stations are selected, the displays for the unused stations will

    remain blank. For example, in the above illustration, station 4 is blank because the number of stations is set to 3.

    Setting the correct number of stations is important because this setting determines how many press strokes occur before the sequence restarts.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    47

    Security Code Menu (Operation mode) (only available when the security code is enabled)

    In the Operation mode, the Security Code screen is used to enter the 4-digit security code to unlock access to the protected features, and to lock the unit again after the desired changes are made.

    To enter the Security Code

    The security code consists of four numerical digits, each with a range of 0-9. For security reasons, the digits are not displayed on the LCD as they are entered. The digits are represented by ‘*’ with the currently selected digit highlighted. Digits are

    incremented and decremented with the middle arrow buttons, or . The button accepts the current digit and advances to the next digit. 1) Push or to increment or decrement the current digit.

    2) Push to accept the current digit and advance to the next digit. 3) Repeat steps 1 and 2 until all four digits have been entered. If the security code is incorrect, the first digit will once again be highlighted. If the security code was accepted, the screen will return to the Home menu and lock indicator will be gone to indicate that all features are now unlocked. Note: The default security code is 4-1-7-0 The following example demonstrates the sequence to enter a security code.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    48

    Sequence to Enter a Security Code

    Notes: Highlighted digits start with a value of zero. To enter a zero, like the third digit in the

    above example, simply press without pressing any other button.

    Digits can be entered with either the or buttons. For example, the digit “9” can be entered by pressing nine times or by pressing one time.

    If you suspect that an incorrect digit was entered, you can press to cancel the code entry and start again at the first digit.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    49

    To lock the Security Code Once a valid security code has been entered, the lock indicator will disappear to indicate that the security code is unlocked. When the code is unlocked all settings and functions are active. After the desired changes have been made by authorized personnel, the security code should be locked again so that no further changes are made. This is done on the Security Code screen.

    To lock the security code, press . The PWi Forging monitor will return to the Main screen and the lock indicator will reappear to indicate the security code is once again locked.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    50

    Configuration Mode - Overview

    To view other menus Push or until the desired menu is shown.

    Note: Depending on the trigger method and mode selected, some menus will not be shown.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    51

    Configuration Mode - Description Channel Menu

    The Channel menu controls the number of load channels that the monitor will display.

    To change the Number of Channels

    1) Push to enter change mode. Current value is then selected.

    2) Push or to change the value.

    3) Push to accept the change, or push to cancel the change.

    Note: When the number of channels is set to 2 for a 2-channel unit, the total load is divided into a left half (Channel 1) and a right half (Channel 2).

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    52

    Decimal Point Menu

    The Decimal Point menu controls the precision with which the load values are displayed. Up to 3 decimal places can be displayed.

    To change the Decimal Point

    1) Push to enter change mode. Current value is then selected.

    2) Push or to change the value.

    3) Push to accept the change, or push to cancel the change.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    53

    Capacity Menu

    The Capacity menu allows the user to enter the rated capacity value for the press.

    To view Capacity Values Capacity values are shown in the associated corners.

    To change Capacity Values

    1) Push to enter change mode. Total channel is then selected.

    2) Push to select the desired channel.

    3) Push or to change the value, or

    Push or to change in a larger increment.

    4) Push to accept the change, or push to cancel the change. 5) Repeat from step 2 to make change on other channels.

    6) Push to exit change mode.

    Note: When the Total Channel value is changed, the values of the corner channels are updated automatically with a value of Total Capacity divided by the number of channels. For example, if a total capacity of 800 is entered, the corner channel capacities will become 200 (800 ÷ 4 if there are four channels).

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    54

    Trigger Menu

    The Trigger menu determines the method that the monitor uses to capture the load.

    To change the Trigger Method

    1) Push to enter change mode. Current setting is then selected. 2) Push or to change the setting.

    3) Push to accept the change, or push to cancel the change.

    Notes: When the trigger method is changed to threshold, the threshold value is automatically

    set to 6% of capacity. This value can be adjusted on the Threshold menu. Choose resolver triggering only if the optional Resolver Board is installed.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    55

    Threshold Menu (only available when trigger mode is set to Threshold)

    When using threshold triggering for load capture, the Threshold menu provides a means of adjusting the load value at which the monitor will capture the stroke. Total loads below this value will be ignored.

    To change the Threshold Value

    1) Push to enter change mode. Current setting is then selected.

    2) Push or to change the setting, or

    Push or to change in a larger increment.

    3) Push to accept the change, or push to cancel the change. Notes: If the threshold value is set to zero, the trigger method will automatically be set to probe. If the threshold value is set to capacity, the trigger method will automatically be set to resolver.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    56

    Learn Menu

    The Learn menu provides a way to control the method that is used to calculate the high and low setpoints when the Learn function is used.

    To change the setpoint learning method

    1) Push to enter change mode. Current setting is then selected.

    2) Push or to change the setting.

    3) Push to accept the change, or push to cancel the change.

    Choosing a setpoint learning method While either method can be chosen, it is important to understand how the setpoint learning method will affect the high and low alarm setpoints. As a general rule, choosing to learn setpoints based on a percentage of capacity will generate a larger range of “good” load values than choosing to learn based on a percentage of the benchmark. This effect is more evident if your normal running peak load is relatively small compared to the capacity. Consider the following example: A 200-ton capacity press is making good parts at 50 tons. If the high and low setpoints are set to 20%, the following setpoints will be calculated after the Learn function is used.

    %Capacity method: 200 tons * 20% = 40 tons Hi Setpoint = 50 tons + 40 tons = 90 tons Lo Setpoint = 50 tons – 40 tons = 10 tons

    %Benchmark method: 50 tons * 20% = 10 tons Hi Setpoint = 50 tons + 10 tons = 60 tons Lo Setpoint = 50 tons – 10 tons = 40 tons

    In this example, choosing the %Benchmark method will produce a much tighter range of good values (20 tons) than the %Capacity method (80 tons).

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    57

    Delay Menu (only available when trigger mode is set to Threshold)

    When using threshold triggering for load capture, the Delay menu provides a means of manually controlling the duration of the stroke capture. Load capture begins when the load crosses the threshold value and ends after the fixed delay time. This is advantageous for applications that normally see the load drop below and then rise above the threshold value more than once within a single press stroke (i.e. a double hit).

    In this example of a double-hit, the load rises above the threshold value, peaks, and then drops below the threshold to end Hit #1. However, the load then rises slightly above threshold once again before finally dropping once more (Hit #2). This behavior will commonly cause the peak tonnage to update twice, which prevents the monitor from displaying the true peak at the end of the stroke. This can be remedied by entering a delay value (1 second in this example), which prevents the stroke from ending too early.

    To change the Delay Value

    1) Push to enter change mode. Current setting is then selected.

    2) Push or to change the setting, or

    Push or to change in a larger increment.

    3) Push to accept the change, or push to cancel the change. Notes: You can choose any time delay value from 0 seconds up to 9.999 seconds. Setting the time delay value to zero disables the delay feature. The load capture will end when the load drops below the threshold value.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    58

    Offset Menu (only available when trigger mode is set to Resolver)

    The press stroke can be viewed as a 360º circle with the top position at 0º (fully opened) and the bottom dead center position at 180º (fully closed). When using resolver triggering for load capture, the offset value allows the resolver position to be zeroed. The offset can be adjusted from 0º (no offset) to 359º.

    Determining the Offset Value needed

    1) Cycle the press to the top position. This should be 0º. 2) Subtract the resolver position shown in the total window from 360 to get the offset

    value. Refer to the following section to enter the offset. To change the Offset Value

    1) Push to enter change mode. Current setting is then selected.

    2) Push or to change the setting, or

    Push or to change in a larger increment.

    3) Push to accept the change, or push to cancel the change. After entering the offset value, the resolver position should read zero. If not, re-calculate the offset value as described above.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    59

    Mode Menu

    The Mode menu provides an alternate method for processing load data.

    To change the Load Processing Mode

    1) Push to enter change mode. Current setting is then selected.

    2) Push or to change the setting.

    3) Push to accept the change, or push to cancel the change. Notes:

    STI mode is not valid for forging applications; therefore the mode should always remain set to PEAK.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    60

    E-Stop Menu

    The E-Stop menu configures the operation of the Emergency Stop (E-Stop) shutdown relay. See page 25 for E-Stop relay location and wiring.

    Description of Emergency Stop relay operation When E-Stop is set to “OFF”:

    All alarms, including capacity alarms, cause the Top-Stop relay to open at the end of the stroke.

    The E-Stop relay has no function.

    When E-Stop is set to “CAP ALARM”: Capacity alarms cause the E-Stop relay to open immediately when an over-capacity

    load occurs. This also applies to CCM alarms if the optional resolver board is installed. Warning: Using the E-Stop relay under heavy loads may result in the ram becoming locked at the bottom of stroke. If this is a concern, the E-Stop relay should not be used.

    The Top-Stop relay will open for high, low, and reverse setpoint violations.

    To change the E-Stop relay operation

    1) Push to enter change mode. Current setting is then selected.

    2) Push or to change the setting.

    3) Push to accept the change, or push to cancel the change.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    61

    Setup Count Menu

    The Setup Count is the maximum number of strokes allowed in Setup mode. It provides a way to ensure that the monitor will not be left in Setup mode indefinitely, protected only by the capacity limits. After the Setup Count value has been reached, the monitor will enter Run mode.

    To change the Setup Count

    1) Push to enter change mode. Current setting is then selected.

    2) Push or to change the value.

    3) Push to accept the change, or push to cancel the change.

    Notes: The Setup Count can be set from zero to 200. To disable the Setup Count feature, change the value to zero.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    62

    Address Menu

    The Address menu displays the current communications address of the monitor and allows it to be changed to provide a unique networking address for use with PressNet or other communications software.

    To change the Address

    1) Push to enter change mode. Current setting is then selected.

    2) Push or to change the setting.

    3) Push to accept the change, or push to cancel the change.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    63

    Baud Rate Menu

    The Baud Rate menu allows the communications speed for the PressNet (RS422-1) Port to be adjusted.

    To change the Baud Rate

    1) Push to enter change mode. Current setting is then selected.

    2) Push or to change the setting.

    3) Push to accept the change, or push to cancel the change.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    64

    Calibration Menu

    The Calibration menu allows for balance and gain adjustment for each load channel.

    To view the Balance Values, Gain Numbers, or Peak Load 1) Push or until the desired item is shown. 2) Values are shown in the associated corners.

    To change the Balance Values and Gain Numbers

    Balance values are changed by adjusting the corresponding Balance pot for each channel. The Balance pots are located on the Analog Board, near the sensor input.

    Gain numbers are changed by adjusting the corresponding Gain pot for each channel. The Gain pots are located on the Analog Board, near the sensor input.

    Note: The calibration procedure is explained in Section 3.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    65

    Security Code Menu (Configuration mode)

    The Security Code menu is used to configure and change the 4-digit security code. When the security code is enabled, most functions in the Operation mode are restricted until the security code is entered.

    To enter the Security Code

    The security code consists of four numerical digits, each with a range of 0-9. For security reasons, the digits are not displayed on the LCD as they are entered. The digits are represented by ‘*’ with the currently selected digit highlighted. Digits are incremented and

    decremented with the middle arrow buttons, or . The button accepts the current digit and advances to the next digit.

    1) Push or to increment or decrement the current digit.

    2) Push to accept the current digit and advance to the next digit. 3) Repeat steps 1 and 2 until all four digits have been entered. If the security code is incorrect, the first digit will once again be highlighted. If the security code was accepted, the option to enable/disable or change the security code will appear. For an example of how to enter the security code, see page 48.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    66

    To enable or disable the Security Code feature Once a valid security code has been entered, the following options will appear.

    If the security code feature is currently enabled, the DSABL (Disable) option appears. In this

    case, pressing will disable the security code. Once disabled, all settings and features in the Operation mode will be unrestricted and the Operation mode’s Security Code menu will not appear.

    Similarly, if the security code feature is currently disabled, the ENABL (Enable) option

    appears. In this case, pressing will enable the security code for the Operation mode.

    To change the Security Code Once a valid security code has been entered, the authorized user then has the option to change the security code if desired. You will notice a message on the LCD asking if you wish to change the security code.

    To begin changing the security code, press the button. The familiar security code entry screen appears. Enter the new 4-digit code. After the new security code has been entered, the LCD will prompt you to verify the new code. Enter the same new 4-digit security code again. If you entered the exact same code both times, you will get a message that the code was changed. If not, you will be informed that the change failed. See the following example for the sequence.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    67

    Sequence to Change the Security Code

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    68

    To reset the Security Code There is a way to reset the security code to its default value of 4-1-7-0, in case the code is forgotten.

    First, navigate to the Configuration mode’s Security Code menu. Then follow this sequence exactly as shown:

    Sequence to Reset the Security Code

    Once the security code is reset to its default value, you may then change the code by following the instructions from the “To change the Security Code” section.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    69

    33:: Calibration Procedure Use the following steps for proper load calibration of the PWi Forging unit. 1) Put the PWi Forging in Setup Mode (see page 33 for details).

    2) Set Press Capacity

    A) Enter the Configuration mode by toggling Dip-Switch 1 to the down position (see page 28 for location of Dip-Switch 1).

    B) Use the or buttons to navigate to the Capacity menu. C) Enter the press capacity for the total and each channel. Refer to the Capacity Menu section on page

    53 for more detail.

    3) Balance the Tonnage Sensors A) Make sure the press is under no load. B) Use the or buttons to navigate to the Calibration menu. C) Open the PWi Forging enclosure and locate the Balance and Gain pots on the Analog Board (see

    Figure 1.7 and Figure 1.8). D) Adjust the balance pot for CH1 until the balance value for channel 1 reads zero. Turn the pot

    clockwise to increase the balance value and counter-clockwise to decrease the balance value.

    E) Repeat for each of the remaining channels.

    4) Find the Shut Height of the Press A) Jog the press until the ram is at bottom dead center (BDC) or 180º without any load cells or die in

    the press. B) Determine the amount of spacers needed with your load cells. Cycle the press without load cells to

    insure correct height.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    70

    5) Place the Load Cells in the Correct Position in the Press A) All load cells should be equal distance from the sides and front and rear. For example, 12” from the

    sides, 10” from front and rear. Load cells are typically placed at each corner of the press’s bed. B) Cycle the press without hitting the load cells first. C) Place cardboard on the top and bottom of the load cells.

    6) Cycle the Press A) While still in the Calibration menu, push or to display the PEAK tonnage. B) Further adjust the shut height so that the press impacts the load cells and generates a load at 100%

    of press capacity. See warning below. WARNING: Depending on the press capacity and the size of the load cells being used, loading the press at capacity with load cells could indent the ram or bolster. To prevent this situation from happening, do one of the following:

    a) Calibrate the press only up to 80% of capacity, or b) Use larger load cells to increase the loading surface. For instance, to calibrate a 400 Ton

    press at capacity, use (4) 250 Ton load cells instead of (4) 100 Ton load cells.

    7) Gather, Record, and Enter Data A) Record the load cell numbers for each of the channels. These are the load values of the press

    corners. B) Record the peak tonnage values from the PWi Forging. C) While still in the Calibration menu, push or to display the GAIN numbers. This enables

    the PWi Forging’s shunt. Record the Gain numbers.

    D) Use the following formula to determine the new gain number: E) Repeat the calculation for each channel.

    New Gain Number = (Load Cell reading ÷ Peak Tonnage reading) x Current Gain

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    71

    F) Adjust the gain pot for CH1 until the gain number for channel 1 equals the new calculated gain number. Turn the pot clockwise to increase the gain number and counter-clockwise to decrease the gain number. Repeat for each of the remaining channels.

    G) Push or to display the BAL (balance) values. Use the balance pots to re-balance the channels if needed.

    H) Push or to display the GAIN numbers. If they are not equal to the calculated gain numbers, re-adjust them. Repeat steps F-H as needed.

    8) Verify Results and Repeat A) While still in the Calibration menu, push or to display the PEAK tonnage. B) Cycle the press. C) Verify that the load cell values and the PWi Forging’s peak tonnage values are same. If not, repeat

    step 7 until the values are the same.

    9) Make Linearity Check A) Raise the shut-height in .020 to .030 inch increments to decrease tonnage. B) Cycle the press and impact the load cells. C) Compare the tonnage applied to the load cells to the tonnage displayed on the PWi Forging. These

    values should be documented.

    10) Document calibration details on the Calibration Sheet (Form #1224) provided and file it for future reference.

    11) Record Gain Numbers

    A) While still in the Calibration menu, push or to display the GAIN numbers. B) Record these numbers on the calibration card located on the door inside of the unit. See section 4

    for details on the calibration card.

    12) Calibration Complete

    The calibration procedure is now complete. Contact Toledo Integrated Systems’ Service Department for assistance if needed. Our Service Department can be reached at 419-867-4170, Monday through Friday, 8:00 AM to 5:00 PM.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    72

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    73

    44:: Calibration Information Label The Calibration Information Label is provided to document the Gain Numbers (CAL#) and other important configuration data. This card is located inside of the unit on the door. Below is an example of the information that should be documented.

    1) Cal By

    The name of the person that performed the calibration procedure. 2) Date

    The date that the calibration was completed. 3) Press No.

    The press on which the monitor is installed. 4) Address

    The network/communication address for the monitor. 5) Capacity (CH0)

    The total capacity of the press. For a double-action press, this is the capacity of the outer slide. 6) Unit

    The type of load being measured. Common examples include Tons and kN (kiloNewtons). 7) Thres. Value

    If the trigger method is set to Threshold, check this box and record the configured threshold value. 8) Probe

    If the trigger method is set to Probe, check this box. 9) CAL# (CH1-4)

    Record the Gain Numbers from step 11 of the Calibration Procedure here. 10) STI Value

    If the mode is set to STI, check this box and enter the STI configuration number here. 11) Delay Value

    The configured delay value, if used. 12) Notes

    Enter any important notes related to the monitor’s configuration in this area.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    74

    If the optional Resolver Board was purchased, an additional calibration label is included to document the resolver information and/or the channel 6-9 analog input information.

    13) Capacity (CH5)

    The total capacity associated with load sensors 6-9. For example, in the case of a double-action press where sensors 6-9 are used to measure the load for the inner slide, the CH5 capacity is the total capacity for the inner slide.

    14) Resolver If the trigger method is set to Resolver, check this box.

    15) Offset Value When using Resolver triggering, enter the offset value that is required to zero the press angle.

    16) CAL# (CH6-9) Record the Gain Numbers from step 11 of the Calibration Procedure here.

    17) Resolver Configuration Record the resolver dip switch settings from the Resolver Board here.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    75

    55:: Operator’s Guide

    The PWi Forging displays a variety of information by organizing it into menus. The Home menu is shown above. The Corner Displays show peak station load and the LCD Display shows %Variation from the Benchmark for each station. From this menu, you can place the PWi Forging into Setup Mode or Learn Mode and view the run status. While setting a die in the press, place the PWi Forging into Setup Mode by pressing the and buttons until

    the LCD Display shows SETUP. Press the button to accept. Run material through the press until a good part is formed. If running an established part whose setpoints have been saved to a job number, follow the instructions below to load the job. Otherwise, place the PWi Forging into Learn Mode by pressing the and buttons until the LCD Display shows LRN. Press the button to accept. After one sequence through the stations, the PWi Forging establishes a new benchmark and calculates new high and low setpoints based on the percentage settings from the Setpoint menu.

    Jobs save the setpoints related to a part so that you do not have to relearn them every time that part is ran. To load

    a job, use the and buttons to access the JOB menu. The current job number is shown above the and buttons on the LCD Display. To change the job number, press the button, then press the or buttons to increase or decrease the job number. When the desired job number is shown, press the button to load it.

    To avoid nuisance alarms and shutdowns while adjusting the press, put the PWi Forging in Setup Mode, as

    described above. Setup Mode still protects the press from an over-capacity hit, but it will not shut the press down for a high or low setpoint violation.

    The high and low setpoints can be displayed by using the and buttons to access the SETPT (Setpoint) menu. While on the Setpoint menu, use the and buttons to display the HI-% (High %), LO-% (Low %), and other setpoints. The high and low percentages are shown on the LCD Display for each station and the actual high and low setpoints are shown on the Station Load Displays.

    When an alarm occurs, the status on the Home menu will change to ALM and the Station Load Display(s) for the

    violated channel(s) will flash. Press the button to go to the ALARM Menu. The type of alarm and the station number are shown above the and buttons on the LCD Display. If more than one alarm has occurred you can use these buttons to scroll through the list of alarms. To reset an alarm, press the button.

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    76

  • PWi Forging User’s Manual

    Doc #17663 Rev A Page

    Toledo Integrated Systems

    77

    66:: Appendix

    I) Sensor Installation (Doc# 11080) II) Calibration Sheets (2) (Form# 1224)

  • INSTALLING T400 LOAD SENSORS

    The above illustrations represent the proper arrangement of Model T400 Load Sensor kit parts using either the Drill and Tap method or the Weld method. A proper installation is necessary to produce good results. Before installing the sensors, please read the appropriate instructions listed below. Sensor Placement Page 2 Press Frame Page 3 Pitman Mount Page 4 Drill and Tap Method of Installing Sensors Page 5 Weld Method of Installing Sensors Page 6 T400 Enclosure Mounting Details Page 7

    Doc #: 11080 Rev :A T400 INSTALLATION PAGE 1

  • Doc #: 11080 Rev :A T400 INSTALLATION PAGE 2

  • Doc #: 11080 Rev :A T400 INSTALLATION PAGE 3

  • Doc #: 11080 Rev :A T400 INSTALLATION PAGE 4

  • USING THE T400 SENSOR INSTALLATION FIXTURE KIT No. 1977-749

    (METRIC INSTALLATION FIXTURE KIT No. 1974-749)

    DRILL AND TAP METHOD FOR MOUNTING SENSORS

    BE SURE THE SENSOR LOCATION FOLLOWS THE BEST LOCATION DESCRIBED ON THE PREVIOUS PAGES.