purlin notes: legend - major projects

9
SC1 SK2800 F.2 SK2800 F.1 BR2 BR1 BR 1 BR1 BR 1 BR2 BR2 BR1 BR 1 SB5 SB5 BR1 BR 1 BR2 BR2 BR1 BR 1 BR2 BR1 BR1 SB4 B R 1 BR1 BR2 BR 1 BR1 BR2 SC1 SC1 SC1 SC1 SC1 SC1 SC3 SC3 SC2 SC2 SC2 SC2 SC1 SC1 SC1 SC1 SC1 SC2 SC2 SC2 SC2 SC2 SC2 SB2 SB2 SB2 SB2 SB2 SB2 SB2 SB2 SB2 SB2 SC2 SC2 SC2 SC2 SC2 SC2 SC2 SC2 SC2 SC2 SC2 SC2 SC2 SC2 SC2 SB1 SB1 SB2 SB2 SB2 SB2 SB2 SB2 SB2 SB2 SB2 125 125 150 150 WH1 SK2800 F.3 TRUSS = TR1 2 / V B 2 2 / V B 2 2/VB2 200 125 SC1 SK2800 F.4 SK2800 F.5 BEAM FIXED TO RETAINING WALL FULLY SHOP WELDED SC3/SB4 FRAME SB3 2/VB2 2/VB2 VB1 REFER TO DRAWING SK0900-SK1400 FOR STRUCTURE TO ADJACENT PROPOSED BUILDING ROOF FRAMING NOTES: 1. REFER ALSO TO SPECIFICATIONS AND GENERAL NOTES ON DRAWING NUMBER S---- 2. MECHANICAL PENETRATIONS IN ROOF ARE SHOWN INDICATIVELY ONLY REFER MECHANICAL ENGINEERS DRAWINGS FOR SIZE AND EXACT LOCATIONS 3. ALL EXPOSED STEEL TO BE HOT DIPPED GALVANISED 4. ALLOWANCE FOR THE SUPPORT OF MECHANICAL SERVICES SHOULD BE MADE BY THE CONTRACTOR AS FOLLOWS: - FULL HEIGHT VERTICAL DUCTS ARE TO BE SUPPORTED FROM THE CONCRETE FLOOR SLAB BELOW - SERVICES ARE TO BE SUPPORTED FROM THE PURLIN WEBS ONLY - DUCTS, PIPES, CABLE TRAYS ETC. PERPENDICULAR TO PURLINS ARE TO BE SUPPORTED FROM EVERY PURLIN (1500 MAX. CTS.) - DUCTS, PIPES, CABLE TRAYS ETC. PARALLEL TO PURLINS ARE TO BE SUPPORTED FROM 3 No. PURLINS USING 75 x 75 x 6 EA SPREADERS AT 1500 MAX. CTS. - ALL HEAVY LOAD SUPPORTS ARE TO BE APPROVED BY THE ENGINEER. LOADS GREATER THAN 300kg TO BE SUPPORTED BY STEELWORK PROVIDED BY THE SUB-CONTRACTOR AND APPROVED BY THE ENGINEER 5. ALLOW FOR AN ADDITIONAL 2 No. 250 UB 31 TRIMMER BEAMS TO MECHANICAL ROOF VENTS. LOCATIONS TO ARCHITECT AND MECHANICAL DRAWINGS (TYPICALLY) 6. ALLOW FOR 50 x 50 x 3 EA FLY BRACES TO ROOF BEAMS AT 1/3 POINTS (TYPICALLY) PURLIN NOTES: 1. REFER MEMBER SCHEDULE FOR PURLIN SIZE AND CENTRES 2. PURLINS TO BE LAPPED AT 900mm MAX. CTS. AT SUPPORTS (UNO). 3. REFER ARCHITECTURAL DRAWINGS FOR ADDITIONAL PURLINS REQUIRED TO SUPPORT FLASHING, GUTTERS AND OTHER NON-STRUCTURAL ITEMS 4. PROVIDE BRIDGING AS INDICATED IN MEMBER SCHEDULE, FIXED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS 5. PROVIDE TRIMMING ANGLE TO END OF PURLINS TO SUPPORT END OF SHEETING 6. PURLIN SETOUT SHOWN ON PLAN INDICATIVE ONLY, SHOP DETAILER TO CONFIRM ACTUAL NUMBER OF PURLINS REQUIRED (UNLESS OTHERWISE NOTED) (UNLESS OTHERWISE NOTED) LEGEND (UNLESS OTHERWISE NOTED) DENOTES SPAN DIRECTION OF BONDEK 125 DENOTES THICKNESS OF SLAB ABN 29 102 716 352 Consulting Engineers, Structural - Civil - Infrastructure Level 6, 37 York Street, Sydney, NSW 2000, Australia Tel: +61 2 8247 8400 Fax: +61 2 8247 8444 [email protected] www.bonaccigroup.com Bonacci Group (NSW) Pty Ltd COPYRIGHT All rights reserved. These drawings, plans and specifications and the copyright therein are the property of the Bonacci Group and must not be used, reproduced or copied wholly or in part without the written permission of the Bonacci Group. Rev Description Date By App Designed Drawn Scale Date Sheet Project Ref. Project Director Approved Date North Drawing No. Rev A1 0 10 20 30 50 100 A1 1 : 100 21/09/2017 3:37 :51 PM C:\Users\twatso n\Documents\202172601S-GOU LBURN HOSPITAL LINK STRUC TURE-RST16-CENTRAL_TW2 201.rvt GOULBURN HOSPITAL AND HOSPITAL SERVICES REDEVELOPMENT 202172601S SK2100 AC TJW LINK CORRIDOR FRAMING PLAN - GROUND LEVEL P2 SCHEMATIC DESIGN STEEL FRAMING SCHEDULE MARK SIZE REMARKS VB1 168 x 4.8 CHS VB2 75 x 75 x 6 EA WH1 150 x 100 x 4 RHS ON FLAT STEEL FRAMING SCHEDULE MARK SIZE REMARKS BR1 90 x 90 x 8 EA BR2 139 x 3.5 CHS BR4 150 x 150 x 5 SHS P1 Z15019 AT 1200 MAX. CTS. 2 ROWS BRIDGING R1 150 PFC R2 250 UB 26 RA1 75 x 75 x 8 EA SB1 410 UB 54 SB2 310 UB 32 SB3 150 x 150 x 10 EA SB4 460 UB 82 SB5 200 UC 60 SC1 150 x 150 x 9 SHS SC2 100 x 100 x 6 SHS SC3 460 UB 82 STEEL COLUMN SHEDULE MARK SIZE REMARKS SC1 150 x 150 x 9 SHS SC2 100 x 100 x 6 SHS SC3 460 UB 82 SUSPENDED CORRIDOR SLAB EXTENT SHOWN INDICATIVELY. CORRIDOR SLAB TO TRANSITION TO SLAB ON GRADE TO TIE IN WITH EXISTING GROUND LEVELS. TYPICAL ALL STEELWORK BELOW GROUND TO BE PAINTED WITH 2 COATS OF HIGH BUILD EPOXY P1 ISSUED FOR SCHEMATIC DESIGN 21.07.17 TJW P2 RE-ISSUED FOR SCHEMATIC DESIGN 21.09.17 TJW

Upload: others

Post on 14-Feb-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PURLIN NOTES: LEGEND - Major Projects

SC1

SK2800F.2

SK2800F.1

BR

2

BR1BR1 BR1

BR1

BR

2

BR

2

BR1 BR1

SB5

SB5

BR1BR1

BR

2

BR

2

BR1 BR1

BR

2

BR1 BR1

SB

4

BR1 BR1

BR

2

BR1BR1

BR

2

SC1

SC1

SC1

SC1

SC1

SC1 SC3

SC3

SC2

SC2

SC2

SC2SC1

SC1

SC1

SC1

SC1

SC2SC2

SC2SC2

SC2SC2

SB2

SB2 SB2

SB2

SB2

SB2 SB2

SB2

SB

2

SB

2

SC2

SC2

SC2

SC2

SC2SC2SC2

SC2

SC2

SC2

SC2

SC2

SC2

SC2 SC2

SB

1

SB

1

SB2

SB2

SB2

SB2 SB2

SB2

SB2

SB

2

SB

2

125

125

150150

WH1

SK2800F.3

TRUSS = TR1

2/VB2

2/VB2

2/V

B2

200

125

SC1

SK2800F.4

SK2800F.5

BEAM FIXED TORETAINING WALL

FULLY SHOP WELDEDSC3/SB4 FRAME

SB32/VB2

2/VB2

VB

1

REFER TO DRAWING SK0900-SK1400FOR STRUCTURE TO ADJACENTPROPOSED BUILDING

ROOF FRAMING NOTES:1. REFER ALSO TO SPECIFICATIONS AND GENERAL NOTES ON DRAWING NUMBER S----2. MECHANICAL PENETRATIONS IN ROOF ARE SHOWN INDICATIVELY ONLY

REFER MECHANICAL ENGINEERS DRAWINGS FOR SIZE AND EXACT LOCATIONS3. ALL EXPOSED STEEL TO BE HOT DIPPED GALVANISED4. ALLOWANCE FOR THE SUPPORT OF MECHANICAL SERVICES SHOULD BE MADE BY

THE CONTRACTOR AS FOLLOWS:- FULL HEIGHT VERTICAL DUCTS ARE TO BE SUPPORTED FROM THE CONCRETE

FLOOR SLAB BELOW- SERVICES ARE TO BE SUPPORTED FROM THE PURLIN WEBS ONLY- DUCTS, PIPES, CABLE TRAYS ETC. PERPENDICULAR TO PURLINS ARE TO BE

SUPPORTED FROM EVERY PURLIN (1500 MAX. CTS.)- DUCTS, PIPES, CABLE TRAYS ETC. PARALLEL TO PURLINS ARE TO BE SUPPORTED

FROM 3 No. PURLINS USING 75 x 75 x 6 EA SPREADERS AT 1500 MAX. CTS.- ALL HEAVY LOAD SUPPORTS ARE TO BE APPROVED BY THE ENGINEER. LOADS

GREATER THAN 300kg TO BE SUPPORTED BY STEELWORK PROVIDED BYTHE SUB-CONTRACTOR AND APPROVED BY THE ENGINEER

5. ALLOW FOR AN ADDITIONAL 2 No. 250 UB 31 TRIMMER BEAMS TO MECHANICALROOF VENTS. LOCATIONS TO ARCHITECT AND MECHANICAL DRAWINGS (TYPICALLY)

6. ALLOW FOR 50 x 50 x 3 EA FLY BRACES TO ROOF BEAMS AT 1/3 POINTS (TYPICALLY)

PURLIN NOTES:1. REFER MEMBER SCHEDULE FOR PURLIN SIZE AND CENTRES2. PURLINS TO BE LAPPED AT 900mm MAX. CTS. AT SUPPORTS (UNO).3. REFER ARCHITECTURAL DRAWINGS FOR ADDITIONAL PURLINS REQUIRED TO

SUPPORT FLASHING, GUTTERS AND OTHER NON-STRUCTURAL ITEMS4. PROVIDE BRIDGING AS INDICATED IN MEMBER SCHEDULE, FIXED IN ACCORDANCE

WITH MANUFACTURERS SPECIFICATIONS5. PROVIDE TRIMMING ANGLE TO END OF PURLINS TO SUPPORT END OF SHEETING6. PURLIN SETOUT SHOWN ON PLAN INDICATIVE ONLY, SHOP DETAILER TO CONFIRM

ACTUAL NUMBER OF PURLINS REQUIRED

(UNLESS OTHERWISE NOTED)

(UNLESS OTHERWISE NOTED)

LEGEND(UNLESS OTHERWISE NOTED)

DENOTES SPAN DIRECTION OF BONDEK

125 DENOTES THICKNESS OF SLAB

ABN 29 102 716 352Consulting Engineers, Structural - Civil - InfrastructureLevel 6, 37 York Street, Sydney, NSW 2000, AustraliaTel: +61 2 8247 8400 Fax: +61 2 8247 [email protected]

Bonacci Group (NSW) Pty Ltd

COPYRIGHT All rights reserved.These drawings, plans and specifications and the copyright therein are the property of the BonacciGroup and must not be used, reproduced or copied wholly or in part without the written permissionof the Bonacci Group.

Rev Description Date By App

Designed

Drawn

Scale

Date

Sheet

Project Ref.

Project Director Approved Date North

Drawing No. Rev

A1

010

2030

5010

0

A1

1 : 100

21/0

9/20

17 3

:37 :

51 P

MC

:\Use

rs\tw

atso

n\D

ocum

ents

\202

1726

01S

-GO

ULB

UR

N H

OS

PIT

AL

LIN

K S

TR

UC

TU

RE

-RS

T16

-CE

NT

RA

L_T

W2 2

01.r

vt

GOULBURN HOSPITAL ANDHOSPITAL SERVICESREDEVELOPMENT

202172601S SK2100

AC

TJW

LINK CORRIDORFRAMING PLAN - GROUND LEVEL

P2

SCHEMATIC DESIGN

STEEL FRAMING SCHEDULE

MARK SIZE REMARKS

VB1 168 x 4.8 CHS

VB2 75 x 75 x 6 EA

WH1 150 x 100 x 4 RHS ON FLAT

STEEL FRAMING SCHEDULE

MARK SIZE REMARKS

BR1 90 x 90 x 8 EA

BR2 139 x 3.5 CHS

BR4 150 x 150 x 5 SHS

P1 Z15019 AT 1200 MAX. CTS. 2 ROWS BRIDGING

R1 150 PFC

R2 250 UB 26

RA1 75 x 75 x 8 EA

SB1 410 UB 54

SB2 310 UB 32

SB3 150 x 150 x 10 EA

SB4 460 UB 82

SB5 200 UC 60

SC1 150 x 150 x 9 SHS

SC2 100 x 100 x 6 SHS

SC3 460 UB 82

STEEL COLUMN SHEDULE

MARK SIZE REMARKS

SC1 150 x 150 x 9 SHS

SC2 100 x 100 x 6 SHS

SC3 460 UB 82

SUSPENDED CORRIDOR SLAB EXTENTSHOWN INDICATIVELY. CORRIDOR SLAB TOTRANSITION TO SLAB ON GRADE TO TIE INWITH EXISTING GROUND LEVELS. TYPICAL

• ALL STEELWORK BELOW GROUND TO BE PAINTED WITH 2 COATS OFHIGH BUILD EPOXY

P1 ISSUED FOR SCHEMATIC DESIGN 21.07.17 TJW

P2 RE-ISSUED FOR SCHEMATIC DESIGN 21.09.17 TJW

Page 2: PURLIN NOTES: LEGEND - Major Projects

SK2800F.2

SK2800F.1

SB5

SB5

BR1BR1

BR1 BR1 BR1BR1

BR1 BR1 BR1BR1 BR1 BR1 BR1 BR1 BR1 BR1

BR

2

SB2SB2

SB2B

R2

SB

4

SB2

BR

2

BR

2

BR

2

BR

2

BR

2

BR

2

SB2 SB2 SB2

WH

1W

H1

WH

1W

H1

WH

1W

H1

R1

R1

R1

R1

R1

R1

R2 BR

1

R2

BR

1

WH1 WH1 WH1

WH1

WH1WH1WH1

R1

R1

R1

R1

WH1WH1WH1WH1

BR1 BR1

BR1

BR1

R1

SC1

SC1

SC1

SC1

SC1

SC1 SC3

SC2

SC2

SC2

SC2SC3

SC1

SC1

SC1

SC1

SC1

SC1

R1

BR

1

WH

1

WH

1

125

RA

1

2/VB2

2/VB2

SK2800F.3

TRUSS = TR1

SK2800F.4

SK2800F.5

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

SC2(U)

R1

P1

P1

P1

P1

SB2

VB

1

VB

1 (U

)

2/VB2 (U)

2/V

B2

(U)

R1

2/VB2 (U)

FULLY SHOP WELDEDSC3/SB4 FRAME

REFER TO DRAWING SK0900-SK1400FOR STRUCTURE TO ADJACENTPROPOSED BUILDING

P1

HATCH DENOTES METAL DECK ROOF.ALLOW FOR 30kg/m² STEELWORK INCLUDINGCONNECTIONS. TYPICAL

ROOF FRAMING NOTES:1. REFER ALSO TO SPECIFICATIONS AND GENERAL NOTES ON DRAWING NUMBER S----2. MECHANICAL PENETRATIONS IN ROOF ARE SHOWN INDICATIVELY ONLY

REFER MECHANICAL ENGINEERS DRAWINGS FOR SIZE AND EXACT LOCATIONS3. ALL EXPOSED STEEL TO BE HOT DIPPED GALVANISED4. ALLOWANCE FOR THE SUPPORT OF MECHANICAL SERVICES SHOULD BE MADE BY

THE CONTRACTOR AS FOLLOWS:- FULL HEIGHT VERTICAL DUCTS ARE TO BE SUPPORTED FROM THE CONCRETE

FLOOR SLAB BELOW- SERVICES ARE TO BE SUPPORTED FROM THE PURLIN WEBS ONLY- DUCTS, PIPES, CABLE TRAYS ETC. PERPENDICULAR TO PURLINS ARE TO BE

SUPPORTED FROM EVERY PURLIN (1500 MAX. CTS.)- DUCTS, PIPES, CABLE TRAYS ETC. PARALLEL TO PURLINS ARE TO BE SUPPORTED

FROM 3 No. PURLINS USING 75 x 75 x 6 EA SPREADERS AT 1500 MAX. CTS.- ALL HEAVY LOAD SUPPORTS ARE TO BE APPROVED BY THE ENGINEER. LOADS

GREATER THAN 300kg TO BE SUPPORTED BY STEELWORK PROVIDED BYTHE SUB-CONTRACTOR AND APPROVED BY THE ENGINEER

5. ALLOW FOR AN ADDITIONAL 2 No. 250 UB 31 TRIMMER BEAMS TO MECHANICALROOF VENTS. LOCATIONS TO ARCHITECT AND MECHANICAL DRAWINGS (TYPICALLY)

6. ALLOW FOR 50 x 50 x 3 EA FLY BRACES TO ROOF BEAMS AT 1/3 POINTS (TYPICALLY)

PURLIN NOTES:1. REFER MEMBER SCHEDULE FOR PURLIN SIZE AND CENTRES2. PURLINS TO BE LAPPED AT 900mm MAX. CTS. AT SUPPORTS (UNO).3. REFER ARCHITECTURAL DRAWINGS FOR ADDITIONAL PURLINS REQUIRED TO

SUPPORT FLASHING, GUTTERS AND OTHER NON-STRUCTURAL ITEMS4. PROVIDE BRIDGING AS INDICATED IN MEMBER SCHEDULE, FIXED IN ACCORDANCE

WITH MANUFACTURERS SPECIFICATIONS5. PROVIDE TRIMMING ANGLE TO END OF PURLINS TO SUPPORT END OF SHEETING6. PURLIN SETOUT SHOWN ON PLAN INDICATIVE ONLY, SHOP DETAILER TO CONFIRM

ACTUAL NUMBER OF PURLINS REQUIRED

(UNLESS OTHERWISE NOTED)

(UNLESS OTHERWISE NOTED)

LEGEND(UNLESS OTHERWISE NOTED)

DENOTES SPAN DIRECTION OF BONDEK

125 DENOTES THICKNESS OF SLAB

ABN 29 102 716 352Consulting Engineers, Structural - Civil - InfrastructureLevel 6, 37 York Street, Sydney, NSW 2000, AustraliaTel: +61 2 8247 8400 Fax: +61 2 8247 [email protected]

Bonacci Group (NSW) Pty Ltd

COPYRIGHT All rights reserved.These drawings, plans and specifications and the copyright therein are the property of the BonacciGroup and must not be used, reproduced or copied wholly or in part without the written permissionof the Bonacci Group.

Rev Description Date By App

Designed

Drawn

Scale

Date

Sheet

Project Ref.

Project Director Approved Date North

Drawing No. Rev

A1

010

2030

5010

0

A1

1 : 100

21/0

9/20

17 3

:37 :

57 P

MC

:\Use

rs\tw

atso

n\D

ocum

ents

\202

1726

01S

-GO

ULB

UR

N H

OS

PIT

AL

LIN

K S

TR

UC

TU

RE

-RS

T16

-CE

NT

RA

L_T

W2 2

01.r

vt

GOULBURN HOSPITAL ANDHOSPITAL SERVICESREDEVELOPMENT

202172601S SK2200

AC

TJW

LINK CORRIDORFRAMING PLAN - LEVEL 1

P2

SCHEMATIC DESIGN

STEEL FRAMING SCHEDULE

MARK SIZE REMARKS

VB1 168 x 4.8 CHS

VB2 75 x 75 x 6 EA

WH1 150 x 100 x 4 RHS ON FLAT

STEEL FRAMING SCHEDULE

MARK SIZE REMARKS

BR1 90 x 90 x 8 EA

BR2 139 x 3.5 CHS

BR4 150 x 150 x 5 SHS

P1 Z15019 AT 1200 MAX. CTS. 2 ROWS BRIDGING

R1 150 PFC

R2 250 UB 26

RA1 75 x 75 x 8 EA

SB1 410 UB 54

SB2 310 UB 32

SB3 150 x 150 x 10 EA

SB4 460 UB 82

SB5 200 UC 60

SC1 150 x 150 x 9 SHS

SC2 100 x 100 x 6 SHS

SC3 460 UB 82

STEEL COLUMN SHEDULE

MARK SIZE REMARKS

SC1 150 x 150 x 9 SHS

SC2 100 x 100 x 6 SHS

SC3 460 UB 82

• ALL STEELWORK BELOW GROUND TO BE PAINTED WITH 2 COATS OFHIGH BUILD EPOXY

P1 ISSUED FOR SCHEMATIC DESIGN 21.07.17 TJW

P2 RE-ISSUED FOR SCHEMATIC DESIGN 21.09.17 TJW

Page 3: PURLIN NOTES: LEGEND - Major Projects

SK2800F.2

SB5

SB5

BR1BR1

BR1BR1 BR1 BR1BR1BR1 BR1BR1 BR1BR1 BR1

BR1BR1BR1 BR1BR1

BR

2

BR

2

BR

2

BR

2

BR

2

BR

2

SB

4

R1

R1

RA

1

WH1

WH1

WH1

WH1

WH1

WH1 WH1

WH1

SK2800F.3

TRUSS = TR1

SK2800F.4

SK2800F.5

P1

SC2(U)

SC2(U)

SC3(U)

SC3(U)

SC1(U)

SC1(U)

SC1(U)

SC1(U)

SC2(U)

SC2(U)

VB

1 (U

)

2/VB2 (U)

2/VB2 (U)

REFER TO DRAWING SK0900-SK1400FOR STRUCTURE TO ADJACENTPROPOSED BUILDING

FULLY SHOP WELDEDSC3/SB4 FRAME

ROOF FRAMING NOTES:1. REFER ALSO TO SPECIFICATIONS AND GENERAL NOTES ON DRAWING NUMBER S----2. MECHANICAL PENETRATIONS IN ROOF ARE SHOWN INDICATIVELY ONLY

REFER MECHANICAL ENGINEERS DRAWINGS FOR SIZE AND EXACT LOCATIONS3. ALL EXPOSED STEEL TO BE HOT DIPPED GALVANISED4. ALLOWANCE FOR THE SUPPORT OF MECHANICAL SERVICES SHOULD BE MADE BY

THE CONTRACTOR AS FOLLOWS:- FULL HEIGHT VERTICAL DUCTS ARE TO BE SUPPORTED FROM THE CONCRETE

FLOOR SLAB BELOW- SERVICES ARE TO BE SUPPORTED FROM THE PURLIN WEBS ONLY- DUCTS, PIPES, CABLE TRAYS ETC. PERPENDICULAR TO PURLINS ARE TO BE

SUPPORTED FROM EVERY PURLIN (1500 MAX. CTS.)- DUCTS, PIPES, CABLE TRAYS ETC. PARALLEL TO PURLINS ARE TO BE SUPPORTED

FROM 3 No. PURLINS USING 75 x 75 x 6 EA SPREADERS AT 1500 MAX. CTS.- ALL HEAVY LOAD SUPPORTS ARE TO BE APPROVED BY THE ENGINEER. LOADS

GREATER THAN 300kg TO BE SUPPORTED BY STEELWORK PROVIDED BYTHE SUB-CONTRACTOR AND APPROVED BY THE ENGINEER

5. ALLOW FOR AN ADDITIONAL 2 No. 250 UB 31 TRIMMER BEAMS TO MECHANICALROOF VENTS. LOCATIONS TO ARCHITECT AND MECHANICAL DRAWINGS (TYPICALLY)

6. ALLOW FOR 50 x 50 x 3 EA FLY BRACES TO ROOF BEAMS AT 1/3 POINTS (TYPICALLY)

PURLIN NOTES:1. REFER MEMBER SCHEDULE FOR PURLIN SIZE AND CENTRES2. PURLINS TO BE LAPPED AT 900mm MAX. CTS. AT SUPPORTS (UNO).3. REFER ARCHITECTURAL DRAWINGS FOR ADDITIONAL PURLINS REQUIRED TO

SUPPORT FLASHING, GUTTERS AND OTHER NON-STRUCTURAL ITEMS4. PROVIDE BRIDGING AS INDICATED IN MEMBER SCHEDULE, FIXED IN ACCORDANCE

WITH MANUFACTURERS SPECIFICATIONS5. PROVIDE TRIMMING ANGLE TO END OF PURLINS TO SUPPORT END OF SHEETING6. PURLIN SETOUT SHOWN ON PLAN INDICATIVE ONLY, SHOP DETAILER TO CONFIRM

ACTUAL NUMBER OF PURLINS REQUIRED

(UNLESS OTHERWISE NOTED)

(UNLESS OTHERWISE NOTED)

ABN 29 102 716 352Consulting Engineers, Structural - Civil - InfrastructureLevel 6, 37 York Street, Sydney, NSW 2000, AustraliaTel: +61 2 8247 8400 Fax: +61 2 8247 [email protected]

Bonacci Group (NSW) Pty Ltd

COPYRIGHT All rights reserved.These drawings, plans and specifications and the copyright therein are the property of the BonacciGroup and must not be used, reproduced or copied wholly or in part without the written permissionof the Bonacci Group.

Rev Description Date By App

Designed

Drawn

Scale

Date

Sheet

Project Ref.

Project Director Approved Date North

Drawing No. Rev

A1

010

2030

5010

0

A1

1 : 100

21/0

9/20

17 3

:38 :

01 P

MC

:\Use

rs\tw

atso

n\D

ocum

ents

\202

1726

01S

-GO

ULB

UR

N H

OS

PIT

AL

LIN

K S

TR

UC

TU

RE

-RS

T16

-CE

NT

RA

L_T

W2 2

01.r

vt

GOULBURN HOSPITAL ANDHOSPITAL SERVICESREDEVELOPMENT

202172601S SK2300

AC

TJW

LINK CORRIDORFRAMING PLAN - LEVEL 2

P2

SCHEMATIC DESIGN

STEEL FRAMING SCHEDULE

MARK SIZE REMARKS

VB1 168 x 4.8 CHS

VB2 75 x 75 x 6 EA

WH1 150 x 100 x 4 RHS ON FLAT

STEEL FRAMING SCHEDULE

MARK SIZE REMARKS

BR1 90 x 90 x 8 EA

BR2 139 x 3.5 CHS

BR4 150 x 150 x 5 SHS

P1 Z15019 AT 1200 MAX. CTS. 2 ROWS BRIDGING

R1 150 PFC

R2 250 UB 26

RA1 75 x 75 x 8 EA

SB1 410 UB 54

SB2 310 UB 32

SB3 150 x 150 x 10 EA

SB4 460 UB 82

SB5 200 UC 60

SC1 150 x 150 x 9 SHS

SC2 100 x 100 x 6 SHS

SC3 460 UB 82

STEEL COLUMN SHEDULE

MARK SIZE REMARKS

SC1 150 x 150 x 9 SHS

SC2 100 x 100 x 6 SHS

SC3 460 UB 82

• ALL STEELWORK BELOW GROUND TO BE PAINTED WITH 2 COATS OFHIGH BUILD EPOXY

P1 ISSUED FOR SCHEMATIC DESIGN 21.07.17 TJW

P2 RE-ISSUED FOR SCHEMATIC DESIGN 21.09.17 TJW

Page 4: PURLIN NOTES: LEGEND - Major Projects

EXISTING GROUND

EXISTING LEVEL 1

SK2800

F.2

WH1 WH1 WH1 WH1

VB2

VB2

SB2SB2SB2SB2

SC

2

SC

2

SC

2

SC

2

SC

2

RW1

EXISTING GROUND

EXISTING LOWER GROUND

EXISTING LEVEL 1

EXISTING LEVEL 2

ONCOLOGY

SK2800

F.1

SK2800

F.3

R1R1

VB2 VB2

SB2SB2

WH1 WH1 WH1 WH1 WH1 WH1

R1

BR2

BR2

SC

2

SC

2

SC

2 SC

2

SC

2

SC

2

SC

2

SC

2

SC

2

SC

2

SC

2

P6

R1

EXISTING GROUND

EXISTING LOWER GROUND

EXISTING LEVEL 1

EXISTING LEVEL 2

ONCOLOGY

SK2800

F.2

BR4

BR4BR

4BR4BR

4

BR4BR4

SC

1

SC

1

SC

1

SC

1

SC

1

SB5

BR4

SC

1

BR4

SC

1

BR

4

BR

4

SC

1

BR

4

BR

4

SC

1

BR4

SC

1

TRUSS = TR1

SB5

SB5

WH1 WH1 WH1 WH1

SB2SB2SB2 SB2

SB2 SB2 SB2 SB2

VB2VB2

VB2VB2

SK2800

F.4

SK2800

F.5

SC

3

SC

2

SC

2

VB2VB2

EXISTING GROUND

EXISTING LEVEL 1

EXISTING LEVEL 2

ONCOLOGY

SK2800

F.3

VB

1

VB1

VB1BR2

BR2

BR2

SC

1

SC

1

SC

1

EXISTING GROUND

EXISTING LOWER GROUND

SUB-BASEMENT

EXISTING LEVEL 1

EXISTING LEVEL 2

ONCOLOGY

SK2800

F.3

SB4

SC

3

SC

3

VB1

SB4

SB4

FULLY SHOP WELDED

SC3/SB4 FRAME

SB2

SB2

SB2 SB2

WH1 W

H1

ABN 29 102 716 352Consulting Engineers, Structural - Civil - InfrastructureLevel 6, 37 York Street, Sydney, NSW 2000, AustraliaTel: +61 2 8247 8400 Fax: +61 2 8247 [email protected]

Bonacci Group (NSW) Pty Ltd

COPYRIGHT All rights reserved.These drawings, plans and specifications and the copyright therein are the property of the BonacciGroup and must not be used, reproduced or copied wholly or in part without the written permissionof the Bonacci Group.

Rev Description Date By App

Designed

Drawn

Scale

Date

Sheet

Project Ref.

Project Director Approved Date North

Drawing No. Rev

A1

01

02

03

05

01

00

A1

1 : 100

21/

09

/2017 3

:38:0

4 P

MC

:\U

sers

\twa

tso n

\Docu

men

ts\2

02172601S

-GO

UL

BU

RN

HO

SP

ITA

L L

INK

ST

RU

CT

UR

E-R

ST

16-C

EN

TR

AL_T

W2

201.

rvt

GOULBURN HOSPITAL AND

HOSPITAL SERVICES

REDEVELOPMENT

202172601S SK2800

AC

TJW

LINK CORRIDOR

FRAMING ELEVATIONS

P2

SCHEMATIC DESIGN

SECTIONSCALE 1 : 100 SK2100

F.1 SECTIONSCALE 1 : 100 SK2000

F.2

SECTIONSCALE 1 : 100 SK2000

F.3 SECTIONSCALE 1 : 100 SK2100

F.4

SECTIONSCALE 1 : 100 SK2000

F.5

P1 ISSUED FOR SCHEMATIC DESIGN 21.07.17 TJW

P2 RE-ISSUED FOR SCHEMATIC DESIGN 21.09.17 TJW

Page 5: PURLIN NOTES: LEGEND - Major Projects

REFER SK2000,SK2100 & SK2200 FORSTRUCTURAL REQUIREMENTS

LINK CORRIDOR TO BEAR ON GROUND. ALLOW FOR 30kg/m2

STEELWORK FOR LINK STRUCTURE INCLUDING CONNECTIONS.ALLOW FOR 100 THICK RAFT SLAB WITH 400Wx400D EDGE ANDINTERNAL BEAMS AT 6m CRS.

C

C

C

C

ALLOW FOR 125 THICK BONDEK SLAB EACH LEVEL, 75kg/m2STRUCTURAL STEELWORK INCLUDING COLUMNS &SUPPORT BEAMS. ALLOW FOR PILED FOUNDATIONS UNDERCOLUMNS.

ROOF: ALLOW FOR 30kg/m2 STEELWORK INCLUDINGCONNECTIONS

IF LG LEVEL IS TO BE CONNECTED, ALLOW FOR 100 THICKRAFT SLAB WITH 400Wx400D EDGE AND INTERNAL BEAMSAT 6m CRS. TYPICAL FOR COVERED WALKWAY.

SUPPORT BEAMS TO CONNECT INTONEW ACUTE SERVICES EDGE BEAM

SLEEVED DOWEL JOINT ATEACH LEVEL TO CONNECTBONDEK LINK CORRIDORSLAB TO EXISTING BUILDING.

C

C

C

C

FIRST FLOOR & GROUND FLOOR: ALLOW FOR 200 THICK BONDEK SLAB &75kg/m2 SUPPORTING STEELWORKINCLUDING BEAMS AND COLUMNS.ALLOW FOR PILED FOUNDATIONSUNDER COLUMNS.

LOWER GROUND FLOOR:ALLOW FOR 100 THICK RAFT SLAB WITH400Wx400D EDGE AND INTERNAL BEAMSAT 6m CRS.

ROOF: ALLOW FOR 30kg/m2 STEELWORKINCLUDING CONNECTIONS

C

C C

STEEL FRAMED STAIR.

C

C

C

C

CORRIDOR SLAB TO BESUSPENDED BONDEKSLAB SUPPORTED ONSTEELWORK. REFERSK2000, SK2100 & SK2200FOR STRUCTURALREQUIREMENTS (SIMILAR).

Page 6: PURLIN NOTES: LEGEND - Major Projects

Page 33

APPENDIX B. CIVIL DRAWINGS

Page 7: PURLIN NOTES: LEGEND - Major Projects

App

Project Ref

Sheet

Scale

Drawn

Designed

Project Director Approved Date

COPYRIGHT All rights reserved.

These drawings, plans and specifications and the copyright therein are the property of the Bonacci

Group and must not be used, reproduced or copied wholly or in part without the written permission

of the Bonacci Group.

By

DateDescriptionRev

North

Drawing No Rev

Date

AppBy

DateDescriptionRev

Project

Drawing

Name

Title

File: G

:\Job\2021726\01\_C

ivil\Issued\D

wg\202172601C

-C

001-C

AD

[P

2].dw

g P

lotted: 26.09.17

at 2:47 P

M B

y: Jonathan F

ranco

BONACCI GROUP ( NSW ) Pty Ltd

ABN 29 102 716 352

Consulting Engineers, Structural - Civil - Infrastructure

Level 6, 37 York Street, Sydney, NSW 2000 Australia

Tel: +61 2 8247 8400 Fax: +61 2 8247 8444

[email protected]

www.bonaccigroup.com

P2DRAWING REGISTER AND CONSTRUCTION NOTES

C00120 21726 01

GOULBURN HOSPITAL ANDHOSPITAL SERVICESREDEVELOPMENT

2021726 - GOULBURN HOSPITAL & HOSPITAL SERVICES REDEVELOPMENT

DRAWING REGISTER AND CONSTRUCTION NOTES - CIVIL & STORMWATER

Page 8: PURLIN NOTES: LEGEND - Major Projects

App

Project Ref

Sheet

Scale

Drawn

Designed

Project Director Approved Date

COPYRIGHT All rights reserved.

These drawings, plans and specifications and the copyright therein are the property of the Bonacci

Group and must not be used, reproduced or copied wholly or in part without the written permission

of the Bonacci Group.

By

DateDescriptionRev

North

Drawing No Rev

Date

AppBy

DateDescriptionRev

Project

Drawing

Name

Title

File: G

:\Job\2021726\01\_C

ivil\Issued\D

wg\202172601C

-C

005-C

AD

[P

1].dw

g P

lotted: 22.09.17

at 4:13 P

M B

y: Jonathan F

ranco

BONACCI GROUP ( NSW ) Pty Ltd

ABN 29 102 716 352

Consulting Engineers, Structural - Civil - Infrastructure

Level 6, 37 York Street, Sydney, NSW 2000 Australia

Tel: +61 2 8247 8400 Fax: +61 2 8247 8444

[email protected]

www.bonaccigroup.com

P1SEDIMENT AND EROSION CONTROL PLANENABLING WORKS C00520 21726 01

GOULBURN HOSPITAL ANDHOSPITAL SERVICESREDEVELOPMENT

Page 9: PURLIN NOTES: LEGEND - Major Projects

App

Project Ref

Sheet

Scale

Drawn

Designed

Project Director Approved Date

COPYRIGHT All rights reserved.

These drawings, plans and specifications and the copyright therein are the property of the Bonacci

Group and must not be used, reproduced or copied wholly or in part without the written permission

of the Bonacci Group.

By

DateDescriptionRev

North

Drawing No Rev

Date

AppBy

DateDescriptionRev

Project

Drawing

Name

Title

File: G

:\Job\2021726\01\_C

ivil\Issued\D

wg\202172601C

-C

006-C

AD

[P

1].dw

g P

lotted: 22.09.17

at 4:13 P

M B

y: Jonathan F

ranco

BONACCI GROUP ( NSW ) Pty Ltd

ABN 29 102 716 352

Consulting Engineers, Structural - Civil - Infrastructure

Level 6, 37 York Street, Sydney, NSW 2000 Australia

Tel: +61 2 8247 8400 Fax: +61 2 8247 8444

[email protected]

www.bonaccigroup.com

P1SEDIMENT AND EROSION CONTROL PLANMAIN WORKS C00620 21726 01

GOULBURN HOSPITAL ANDHOSPITAL SERVICESREDEVELOPMENT