Proven Performance Through The Power Of Experience.Goulds Water Technology combines over 155 years of pump experience with the most modern design and manufacturing systems—deep drawn metal fabrication, laser cutting, laser welding, precision casting, and worldwide design systems—plus a total commitment to quality based on full performance testing of every pump we make.
Whether you need stainless steel, bronze, or cast iron, multi-stage verticals or horizontals, end suction centrifugals or submersibles, there’s a Goulds Water Technology design that’s proven itself through years of dependable service. For booster service, liquid
transfer, spray systems, water circulation, dewa-tering, light chemical and industrial applications, there’s a pump that’s done long time duty. Horizon-tal and vertical multi-stage capacities from 5 gpm to 350 gpm. Submersible capacities from 5 gpm to 500 gpm. And end suction centrifugal capacities from 4 gpm to 5000 gpm. Goulds Water Technol-ogy—a brand offering the power of experience to more than 100 nations of the world. In addition to the standard pump designs shown here, we offer specialized O.E.M. pumps designed to meet the specifications of your particular needs.
TABLE OF CONTENTS
End Suction, Stainless Steel:NPE ..........................................................................................3NPO .........................................................................................3MCS .........................................................................................3SSH ..........................................................................................4ICS/ICS-F .................................................................................43657/3757 ..............................................................................4LB .............................................................................................5
End Suction, Cast Iron:3642/3742 ..............................................................................5MCC .........................................................................................53656LH/3756LH .....................................................................53656/3756 S-Group ...............................................................63656/3756 M&L-Group .........................................................6
Self Priming, Clear Liquids:PrimeLine SP ...........................................................................7GT IRRI-GATOR .......................................................................8PrimeLine ................................................................................82AUW, 3AUW .........................................................................9
High Pressure, Stainless Steel:e-SV ..........................................................................................9LC .......................................................................................... 10HMS ...................................................................................... 10
High Pressure, Cast Iron:GB ......................................................................................... 10HSC ....................................................................................... 10
Vertically Immersed:NPV ....................................................................................... 11
Multi-Stage:MPVN .................................................................................... 12SMVT .................................................................................... 13
Variable Speed Control:Hydrovar and Aquavar CPC .............................................. 14Aquavar ABII ........................................................................ 14
Packaged Pump Systems:AquaForce ........................................................................... 15
Controls:Hydrovar .............................................................................. 16Aquavar CPC ....................................................................... 17Aquavar S-Drive .................................................................. 18Aquavar ABII ........................................................................ 19
PAGE 3
Commercial Watergoulds Water technology
End Suction – Stainless SteelA full range of end suction centrifugal pumps.• Cast iron, bronze, invest-
ment cast 316 stainless steel and 304 stainless steel pump-end materi-als of construction.
• 1 x 11⁄4-5 through 8 x 10-13 sizes.
• Close coupled, frame mounted or engine drive configuration.
• Capacities to 4500 US-GPM (1000 m3/hr.).
• Heads to 500 ft. TDH (152 m).
• Working pressure to 250 PSI.
• Temperatures to 250º F. (120º C.).
• ANSI Flanged and NPT Connections.
• Motors 1 & 3 phase. 50 or 60 hertz ODP, TEFC or explosion proof enclosures 3500 & 1750 RPM.
• Standard John Crane mechanical seals with high temperature and chemical duty options.
CAPACITY
METER FEET
TOTA
L D
YN
AM
IC H
EA
D
0
160
140
120
100
80
60
40
20
50
40
30
20
10
00 20 40 60 80 100 120 140 160 U.S. GPM
0 5 10 15 20 25 30 35 m3/hr
2ST11⁄4" x 11⁄2" – 6
3⁄4 –5 HP3500 RPM
1ST1" x 11⁄4" – 6
1⁄2 –3 HP3500 RPM
3ST11⁄2" x 2" – 6
1–5 HP3500 RPM
3ST 1750 RPM2ST 1750 RPM1ST
1750 RPM
CAPACITY
METERS FEET
TOTA
L D
YN
AM
IC H
EA
D
0
120
100
80
60
40
20
30
20
10
00 25 50 75 100 125 150 175 U.S. GPM
0 5 10 15 20 25 30 50 m3/hr
200 225 250
454035
25
15
5
1" x 11/4" – 63500 RPM
11/4" x 11/2" – 63500 RPM
11/2" x 2" – 63500 RPM
1" x 11/4" – 61750 RPM 11/4" x 11/2" – 6
1750 RPM
11/2" x 2" – 61750 RPM
NPE316L Stainless Steel Enclosed Impeller
NPO316L Stainless Steel Open Impeller
MCS304L Stainless Steel Enclosed Impeller
METERS FEET
TOTA
L D
YN
AM
IC H
EA
D H
CAPACITY Q
0
160
140
120
100
80
60
40
20
50
40
30
20
10
00 20 40 60 80 100 120 140 160 U.S. GPM
0 5 10 15 20 25 30 35 m3/hr
2MS11⁄4" x 11⁄2" – 6
3⁄4 –5 HP3500 RPM
1MS1" x 11⁄4" – 6
1⁄2 –3 HP3500 RPM
3MS11⁄2" x 2" – 6
1–5 HP3500 RPM
PAGE 4
Commercial Watergoulds Water technology
600
500
400
0
100
75
50
25
04003002001000 600
40 60 160 260 m3/hr
CAPACITY
TOTA
L D
YN
AM
IC H
EAD
METERS FEET
500 800
0
3500 RPM
700
20 80 100 120 140
100
200
300
1000900 12001100
180 200 220 240
125
150
175
23SH
27SH
22SH
6SH5SH
8SH
25SH
24SH
11ASH
10ASH
7SH
9ASH
4SH
28SH
U.S. GPM
ICS/ICS-FInvestment Cast 316 Stainless Steel Open Impeller
ICS-FICS
3657/3757Investment Cast 316 Stainless Steel Enclosed Impeller
3657
3757
30
0 20 40 60 80 100 U.S. GPM
0 10 20
0
10
20
30
0
25
50
75
100
125
CAPACITY (Q)
TOTA
L D
YN
AM
IC H
EA
D (H
)
m3/h
FEETMETERS
120
1 x 11⁄4 – 53500 RPM
1 SS
11⁄4 x 11⁄2 – 53500 RPM
2 SS
11⁄4 x 11⁄4 – 51750 RPM2 SS
1 x 11⁄4 – 51750 RPM
1 SS
3500 RPM
120
0 100 200 300 400 U.S. GPM
0 20 100
0
20
40
80
0
60
240
300FEETMETERS
500
8040
180
120
60
CAPACITY (Q)
TOTA
L D
YN
AM
IC H
EA
D (H
)
m3/h
11⁄2 x 2 – 85 SS
11⁄2 x 2 – 63 SS
2 x 3 – 74 SS
60
150
125
100
75
50
25
0
40
30
20
10
04003002001000 600
40 60 160 180m3/hr
CAPACITY
TOTA
L D
YN
AM
IC H
EAD
METERS FEET
500 800
0
1750 RPM
700
20 80 100 120 140
23SH
27SH
22SH
6SH
25SH
24SH
11ASH
10ASH
9ASH
8SH
5SH4SH
28SH
7SH
U.S. GPM
SSH316L Stainless Steel Enclosed Impeller
End Suction – Stainless Steel
PAGE 5
Commercial Watergoulds Water technology
3656LH/3756LHEnclosed Impeller Low Head, Bronze Fitted
FEET
CAPACITY
0 100
TOTA
L D
YN
AM
IC H
EA
D
200 300 400 500 600 700 800 900 10000
10
20
30
40
50
60
21⁄2 x21⁄2 – 53500RPM
2 x 2 – 53500RPM
3 x 3 – 53500RPM
4 x 4 – 53500RPM
5 x 5 – 63500RPM
5 x 5 – 61750 RPM
2 x 2 – 5 1750 RPM 21⁄2 x 21⁄2 – 5 1750 RPM3 x 3 – 5 1750 RPM
4 x 4 – 51750 RPM
U.S. GPM
MCCEnclosed Impeller Iron Casing Stainless-Fitted
CAPACITY Q
METERS FEET
TOTA
L D
YN
AM
IC H
EA
D H
0
160
140
120
100
80
60
40
20
50
40
30
20
10
00 20 40 60 80 100 120 140 160 U.S. GPM
0 5 10 15 20 25 30 35 m3/hr
2MC11⁄4" x 11⁄2" – 6
3⁄4 –5 HP3500 RPM
1MC1" x 11⁄4" – 6
1⁄2 –3 HP3500 RPM
3MC11⁄2" x 2" – 6
1–5 HP3500 RPM
220200180
40 45 50
End Suction – Stainless Steel and Cast IronLB304 Stainless Steel Enclosed Impeller
3642/3742 Cast IronEnclosed Impeller, Iron, Bronze or Bronze Fitted, Cast Iron Pump
FEETPSI
CAPACITY (Q)
U.S. GPM
m3⁄hr
80
60
70
0
TOTA
L D
YN
AM
IC H
EA
D (H
)
100
140
80
0 2 4 8 16
1 2 3 4 5
40
60
160
120
180
6 10 12 14 18 20 22
0
20
0
METERS
50
30
40
0
50
40
30
20
10
20
10
1.0 HP
.75 HP
.5 HP
5 NPSH
20% EFF
25%
30%
32%
10
20 33%
34%
MODEL: LBSIZE: 1 x 11⁄4RPM: 3500
3500 RPM
1 x 11⁄4 - 5
20
40
60
80
100
120
140
160
180
200
0
60
50
40
30
20
10
00 20 40 60 80 100 120
0 5 10 15 20 25
FLOW RATE
U.S.GPM
m3/hr
METERS FEET
TOTA
L D
YN
AM
IC H
EA
D
11⁄4 x 11⁄2 - 5
PAGE 6
Commercial Watergoulds Water technology
1 x 2-7 (3500)1 x 2-8 (3500)
11/2 x 2-6 (3500)11/2 x 2-8 (3500)
2 x 2-5 (3500)21/2 x 21/2-5 (3500)
21/2 x 3-7 (3500)3 x 3-5 (3500)3 x 4-7 (3500)4 x 4-5 (3500)5 x 5-6 (3500)
2 x 21/2-7 (1750)2 x 21/2-7 (3500)
350
300
250
200
150
100
50
0
105
15
0
30
45
60
75
90
0
0 225
1000900800700600500400300200100
200175150125100755025CAPACITY
TOTA
L D
YN
AM
IC H
EA
D
METERS FEET
U.S.GPM
m3/hr
11/2 x 2-8
21/2 x 3-7
11/2 x 2-61 x 2-7
2 x 2-5 21/2 x 21/2-53 x 3-5
3 x 4-7
4 x 4-55 x 5-6
1 x 2-8
2 x 21/2-7
2 x 21/2-7
1750 RPM
1x2 – 8
0
40
60
80METERS
0
10
m3/hr
U.S.GPM
CAPACITY
0 5010 3020 40
1500 50 300200 350100 250
60 70 80
20
TOTA
L D
YNA
MIC
HEA
D
FEET
1x2 – 7
3x4 – 7
11⁄2x2 – 8
21⁄2x3 – 7
11⁄2x2 – 6 / 11⁄2x2 – 6H
3656/3756 M & L-GrOuPEnclosed Impeller Cast Iron or Bronze Fitted Mechanical Seal or Packing
3656 Close Coupled
3756 SAE
3756
500
300
200
100
0
140
20
0
40
60
80
0
0 1000
45003000150012501000750500250
75050030025020015010050CAPACITY
TOTA
L D
YNA
MIC
HEA
D
METERS FEET
U.S.GPM
m3/hr
400
100
120
400
11/2 x 2-10 (3500)21/2 x 3-9 (3500)
21/2 x 3-10 (3500)3 x 4-8 (3500)
3 x 4-10 (3500)4 x 5-8 (3500)
4 x 6-10 (1750)4 x 6-13 (1750)4 x 6-16 (1750)6 x 8-13 (1750)
8 x 10-13 (1750)11/4 x 11/2 -81/2 (3500)
5 x 5-7 (1750)5 x 6-7 (3500)
6 x 8-91/2 (1750)
3 x 4-103500 RPM
4 x 6-101750 RPM
3 x 4-83500 RPM
21/2 x 3-103500 RPM
8 x 10-131750 RPM
6 x 8-131750 RPM
4 x 5-83500 RPM
4 x 6-131750 RPM
4 x 6-161750 RPM
11/2 x 2-103500 RPM
21/2 x 3-93500 RPM
5 x 6-73500 RPM
5 x 6-71750 RPM
6 x 8-91/2
1750 RPM
11/4 x 11/2-91/2
3500 RPM
300
200
100
0
90
20
0
40
60
80
0
0 120
600300100
10080604020CAPACITY
TOTA
L D
YNA
MIC
HEA
D
METERS FEET
U.S.GPM
m3/hr
250
3 x 4-850
150
30
50
70
10
500400200
3 x 4-10
21/2 x 3-8
21/2 x 3-13
21/2 x 3-7
11/2 x 2-1021/2 x 3-9
21/2 x 3-10
11/2 x 2-10 (1750)21/2 x 3-8 (1750)21/2 x 3-9 (1750)
21/2 x 3-10 (1750)21/2 x 3-13 (1750)
3 x 4-8 (1750)3 x 4-10 (1750)
2 x 21/2-7 (1750)11/4 x 11/2-91/2 (1750)
11/4 x 11/2-91/2
2 x 21/2-7
3656/3756 S-GrOuPEnclosed Impeller Iron, Bronze or Bronze Fitted Mechanical Seal or Packing
End Suction – Cast Iron
3656
3756
PAGE 7
Commercial Watergoulds Water technology
PrIMELINE SP ®Enclosed Impeller, Bronze Fitted
General information on Self-Priming pumps.
• General water handling in applications where the liquid level is below the pump.
• Models are available with electric motor, or bearing frame depending on installation requirements.
• Ideal for irrigation, emer-gency cellar draining and farm water supply.
160
140
120
100
80
60
40
20
0
40
30
20
10
00 20 40 60 80 100 120 140
0 5 10 15 20 25 30
CAPACITY
TDH
PRIMELINE SP – 3 HP HIGH HEADCURVE No. CN0681R01
US GPM
m3/hr
FEETMETERS
20’ 15’ 10’ 5’
180
140
120
100
80
60
40
20
0
50
30
20
10
00 20 40 60 80 100 120 180
0 10 20 30 40
CAPACITY
TDH
US GPM
m3/hr
FEETMETERS
140 160
160
40
25’ 20’ 15’10’ 5’
PRIMELINE SP – 5 HP HIGH HEADCURVE No. CN0682R01
120
100
80
60
40
20
0
30
20
10
00 20 40 60 80 100 120 140
0 5 10 15 20 30 40
CAPACITY
TDH
US GPM
m3/hr
FEETMETERS
PRIMELINE SP – 3 HP MEDIUM HEADCURVE No. CN0683R00
160 180 200
25 35
20’ 15’ 10’ 5’25’
160
140
120
100
80
60
40
20
0
40
30
20
10
00 20 40 60 80 120 200 240
0 5 10 15 20 25 50
CAPACITY
TDH
US GPM
m3/hr
FEETMETERS
100 180 220160140
PRIMELINE SP – 5 HP MEDIUM HEADCURVE No. CN0684R00
20’ 15’ 10’ 5’25’
30 35 40 45
Self Priming – Clear Liquids
PAGE 8
Commercial Watergoulds Water technology
GT – IrrIGATOr ®Enclosed Impeller Irrigation Duty
GT07 GT15 GT20 GT30
25'
20'
15'
10'
5'
25'
20'
15'10'
5'GT10
25'
20'
10'
5'
25'
20'
15'
15'
10'
5'
25'
20'
15'
10'
5'
120
100
0
CAPACITY (Q)
TO
TAL
DY
NA
MIC
HE
AD
(H)
FEET
80
60
40
010 20 30 40 50 110
0 5 10 252015
40
30
20
0
10
METERS
U.S. GPM
m3/hr
20
60 70 80 90 100
PrIMELINE®
Self-Priming Centrifugal Pumps
3P3
3P4
2P4
2P32P2
3P2
3P12P1
4P1&
4P2
NEW PRIMELINEHYDRAULICS COVERAGE
0 100 200 300 400 500 600 700 800
0 20 40 60 80 100 120 140 160 180
0
100
200
300
0
20
40
60
80
100
FEE
T
MET
ERS
TOTA
L H
EA
D
CAPACITY IN CUBIC METERS PER HOUR
CAPACITY IN U.S. GPM0
CAPACITY 0
0
M FT.
TOTA
L H
EAD
100 200 300 400 500
0
50
100
150
10
20
40
30
50
500 1000 1500 2000GPM
m /h3
6E1
6E2
4E1
Frame-Mounted Only
Self Priming – Clear Liquids
PAGE 9
Commercial Watergoulds Water technology
0
FLOW (GPM)
HE
AD
TD
H (F
EE
T)
60
40
040 80 120 160 170
120
80
20
100
General information on high pressure multi-stage pumps.• Stainless steel or cast
iron pumps for pressure boosting.
• Applications: potable wa-ter, boiler feed, filtration, RO and Pure Water
• Increased range coverage with new e-SV sizes
• Increased efficiency
• Improved serviceability - fast easy seal replacement without removing the motor
• Compatible with the Hydrovar or Aquavar CPC Variable Speed Pump Controllers
• Flows to 750 GPM, Heads to 1150’
0
1000
FEET
31 2 5 10 20 30 50 100 200
m3/h1 2 4 15 20
GPM
METERS
200
400
600
800
1200
4 40 300 400 500 1000
6 8 10 30 40 60 80 100 140
50
100
150
200
250
300
350
33S33SVV4646SSVV
6666SSVV
9292SSVV15S15SVV
22S22SVV
10S10SVV5S5SVV3S3SVV1S1SVV
125S125SVV
3500 RPM
2AuW, 3AuWPortable Contractor Pumps
2AUW
0
FLOW (GPM)
HE
AD
TD
H (F
EE
T)
60
40
025 50 100 125 145
120
80
20
100
75
3AUW
e-SVVertical Multi-Stage Pumps
0
250
FEET
31 2 5 10 20 30 50 100 200
m3/h1 2 4 15 20
GPM
METERS
50
100
150
200
300
4 40 300 400 500 100
6 8 10 30 40 60 80 100 140
50
75
0
25
3333SSVV
4646SSVV
6666SSVV
9292SSVV
15S15SVV
22S22SVV
10S10SVV5S5SVV3S3SVV
125S125SVV
1750 RPM
1S1SVV
Self Priming – Solids
High Pressure – Stainless Steel
PAGE 10
Commercial Watergoulds Water technology
LC304 Stainless Steel
HMS316L Stainless Steel
0
FEETMETERS
TOTA
L D
YN
AM
IC H
EA
D
US GPM
CAPACITY
50
100
150
200
0
70
60
50
40
30
20
10
90705030100
50
40
30
20
10
EFF
. %
0
2015105
806040200
20151050 m3/ hr
25
NP
SHr (
ft)
MODEL LCCURVE CN0466R003550 RPM
LCB
LCA
53⁄16" DIA. (ALL MODELS)
LCC EFF.
LCCNPSHLCB
NPSHLCANPSH
LCB EFF.LCAEFF.
LCC
1HMS5
1HMS4
1HMS3
1HMS2
2HMS5
2HMS4
2HMS3
2HMS2
2HMS
2HMS
1HMS
1HMS
FEETMETERS
TOTA
L D
YN
AM
IC H
EA
D
US GPM
CAPACITY
50
100
150
200
0
70
60
50
40
30
20
10
30100
40200
98760 m3/hr
250
5 15 25 35
54321 10
80
350
300
0
10
2
4
6
8
NP
SH(f
t)
90
100
20
40
60
EFF
.%
MODEL HMSSIZE: AS SHOWNRPM 3500CURVE: CF0375R00
GBCast Iron or 304 Stainless Steel
HSCCast Iron
0 5 10 15 20 25 30 35
0 1 9
U.S. GPM
M3/Hr.FLOW RATE
0
100
200
00
300
400
500
50
100
150
200
250
50
100
150
FEETPSIMETERS
TOTA
L D
YN
AM
IC H
EA
D
0
5
10
20
NP
SHR –
FEE
T
MODEL: GBRPM: 3500BASED ON ZERO INLET PRESSURECURVE NO. CN0434R02
2 3 4 5 6 7
40
8
15
25RECOMMENDED RANGE1 – 43 GPM
45 50
5GB
7GB
10GB
18GB
25GB
33GB
1210 11
CAPACITY
2 4 6 8 10 12 14 16
60504030201000
20
40
60
80
100
120
140
160
180
200
220
240
70
60
50
40
30
20
10
TOTA
L D
YN
AM
IC H
EAD
FEET
HSC20
HSC15
HSC10
HSC07
U.S. GPM
m3/hr
MODEL HSCSIZE 3/4 – 3 HPRPM 3500
METERS
NPSHR6'
7'
12'
15'
HSC30
High Pressure – Cast Iron / Stainless Steel
PAGE 11
Commercial Watergoulds Water technology
General informa-tion on Vertical Immersed pumps.• 304 and 316 stainless
steel pumps for machine tool, wash system and tank mount applications.
• Pump head is immersed in pumped liquid. May be set at various depths depending on tank.
• Single stage and high pressure multistage ver-sions are available.
Vertically Immersed End-Suction Pump
CAPACITY (Q)
METERS FEET
TOTA
L D
YN
AM
IC H
EA
D (H
)
0
160
140
120
100
60
40
20
50
40
30
20
10
00 20 40 60 80 100 120 140 160 U.S. GPM
0 5 10 15 20 25 30 35 m3/hr
80
1 x 11/4 – 61/2 - 2 HP
3500 RPM1SL 11/4 x 11/2 – 6
3/4 - 5 HP3500 RPM
2SL 11/2 x 2 – 61 - 5 HP
3500 RPM3SL
1SL1750 RPM 2SL 1750 RPM
3SL 1750 RPM
Vertically Immersed – NPV
PAGE 12
Commercial Watergoulds Water technology
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
015 20 30 40 50 100 150 200 300 400 500 1000
15 20 30 40 50 100 150 200 300 400 500 1000
520
480
440
400
360
320
280
240
200
160
120
80
40
0
5004003002001501005040302015109876543
CAPACITY Q
TOTA
L H
EA
D H
(ft.
)
[I.G.P.M.]
[US.G.P.M.]
Q [m3/h]
H [m
]
40.2
40.3
65.165.2
100.1
100.2
125.1
125.2
3550 RPM
Vertical High Pressure Multi-Stage Pump• Rugged vertical
segmented ring construction.
• Available in all iron, stainless fitted or all stainless for fluid compatibility.
• Recommended for a wide variety of industrial, commercial, municipal and building trades pressure boosting applications.
1500
1000
500
400
300
200
100
015 20 30 40 50 100 200 500 1000
15 20 30 40 50 100 200 500 1000
500
400
300
200
100
50
40
30
20
5003002001005040302010543
CAPACITY Q
TOTA
L H
EA
D H
(ft.
)
[I.G.P.M.]
[US.G.P.M.]
Q [m3/h]H
[m]
10
10
2000
2000
3000
3000
2 1000 1500
40.2 40.3 65.1 65.2 100.1
100.2
125.1
125.2
1750 RPM
Vertical High Pressure – MPVN
PAGE 13
Commercial Watergoulds Water technology
1000
900
800
700
600
500
400
300
200
100
050 100 150 200 300 400 500
20 40 60 100 120 140 160 180 200CAPACITY
TOTA
L D
YN
AM
IC H
EA
D
GPM
m3/hr
0 250 350 450 550 600 650 700 750 800 850 900
0 80
300
250
200
150
100
50
0
FEETMETERS
SM3
SM6
SM4SM5
SM2SM1
3500 RPM
Surface Mount Vertical Turbine• Surface mounted, multi-stage vertical turbine pumps. Turbine hydraulics, in-line configuration.
• High efficiency, high pressure design.
• Heavy duty cast iron stainless steel fitted bowl assembly.
• Motor coupling is precision balanced for vibration-free operation.
• Ideal for limited space environments, packaging, and water booster applications.
• Flows from 50 to 850 GPM. TDH up to 880 feet.
• Pre-engineered product with construction options such as stainless steel flanged casing, 50Hz or Premium efficiency motors, and horizontal configurations.
• Unit can be serviced without disturbing system piping arrangement.
• Mechanical cartridge-type seal can be replaced without removing motor.
Vertical High Pressure – SMVT
PAGE 14
Commercial Watergoulds Water technology
General information on Variable Speed Control systems.• Aquavar pump control for
constant pressure, constant flow, or system curve perfor-mance.
Versions from 1 HP to 550 HP.
Pump or wall mounted.
Any three phase centrifugal pump motor (230/460 V).
Eliminate large pressure tanks, separate control panels, by-pass lines, automatic valves, etc.
Up to four pumps can be linked for automatic alterna-tion.
• Aquavar ABII constant pres-sure system provides constant water pressure for homes and commercial properties, up to 100 GPM systems.
Automatically changes pump speed based on water de-mand.
Complete with all needed components for installation.
1 to 5 HP available.
HydrOVAr® ANd AquAVAr® CPCCentrifugal Pump Controller, PLC and Variable Frequency Drive
3500 RPM PUMP CURVE
300
500
600
0 50% 75% 100%
TOTA
L D
YN
AM
IC H
EA
D (f
t.)
KIL
OW
ATT
S
400
25%0
12
10
2
4
6
8
200
100
CAPACITY (gpm)
125%
Constant speed pumppower requirement
Adjustableto matchsystem curve
Automatic pumpshut off at zeroconsumption
Up to 70%energysaving atpartial load
Automatic start of2-4 pumps at peakdemand
AQUAVAR
Variable Speed Control
PAGE 15
Commercial Watergoulds Water technology
Engineered Pump StationsFeatures and Specifications
• All systems are CUL Listed.
• NSF61 approved for potable water.
• Maximum footprint, on most sizes, allow systems to fit through standard doorways.
• 200 – 230 Volt single phase, 200 – 230 Volt three phase, 460 Volt.
• Each system is fabricated with Goulds Water Technology stainless steel or cast iron centrifugal pumps with a variety of electrical and mechanical options to choose from.
• Standard “off the shelf“ motors by Baldor or USEM Motors.
• Significant reduction in energy consumption over fixed speed systems.
• System protection from overvoltage, under-voltage, blocked suction, cavitation, NPSHa, phase loss, short circuit, transducer failure and motor overload.
• Liquid temperatures up to 212º F.
• Ambient temperatures up to 104º F.
• Maximum operating pressures up to 360 psi.
• Pump run-out protection.
• Dry running protection.
• Programmable lead/ lag alternation.
• Programmable system curve/ friction loss compensation.
• Programmable system pressure starting.
• Fault detection and alarms relay.
• Motor run relay.
• Programmable soft start.
• Stainless steel or optional carbon steel piping.
• Isolation valves.
• Optional suction / low pressure switch.
• Optional pressure relief valves and temperature relief valves.
• Optional lightning protection.
• Optional flexible discharge hose.
Engineered Pump Stations – AquaForce™
PAGE 16
Commercial Watergoulds Water technology
Available Configurations Horsepower range Electrical requirement
2 and 3 1 phase, 230 V
3, 5, 7½, 10, 15 3 phase, 460 V
Technical dataSingle Phase Version: 2 and 3 HP
Motor rating: 3 phase, TEFC, 208 – 230 volt, 0 – 60 HZ, Class F insulation
Power Supply: single phase input, 220 – 240 volt, ±10%, 40 – 70 HZ
Three Phase Version: 3 HP to 15 HP
Motor requirements: 3 phase, TEFC, 460 volt, ±10%, 0 – 60 HZ, Class F insulation
Power Supply: 3 phase, 380 – 460 volt, ±10%, 40 – 70 HZ
Pressure Transducer: 316 SS, 17-4 PH stainless steel, 1⁄4“ NPT connection, shielded two wire cable, operating temperature –13º F to 250º F, supply voltage 7- 35 Vdc, 4 – 20mA output. Accuracy is .5% of full scale, proof pressure is 4 x full scale.
display: Two line, 16 characters per line, LCD display. Easy to read pump language, pump on, system pressure, fault codes and system conditions are displayed.
Motor Speed: Variable between 0 – 70 HZ , or maximum RPM at 60 HZ de-pending on speed rating of standard AC induction motor.
Ambient Temperatures (operating): 32 – 104º F (0 – 40º C)
Humidity: 50% relative at 104º F (non-condensing)
90% relative at 68º F (non-condensing)
Inverter design: IGBT, output frequency is a sinus valuated Pulse Width Modulated (PWM)
Enclosure: NEMA 4, IP 55. Avoid excessive dust, corrosives or salts.
Safety Agency Listings: Packaged Hydrovar – , Hydrovar only – (UL Recognized Component)
Protection: Over/Under voltage, motor overload, short circuit, ground fault, motor overheat (with thermistor), programmable no/low flow shut-down, low suction pressure, pump run-out.
Control: Analog input control (4 – 20mA) two point control based on pressure, flow or differential pressure. Control up to 8 pumps in parallel.
Terminals: Dry relay contacts are available for pump run, pump error, low pres-sure switch, remote ON/OFF control, analog output 0 – 10 Vdc (system pressure) and full opened slave pump starter.
Multi-Pumps: RS485 communication SIO (local only) up to four pumps.
Alternate Input: Up to two transducers may be used with each controller. These may be pressure, flow, differential pressure, temperature or other 4 – 20mA signals.
Hydrovar Variable Speed Pump ControllerThe HYDROVAR Pump controller is a combination of a variable frequency motor drive (VFD) and a programmable logic controller (PLC) in one compact package. It mounts on the fan cover of the TEFC pump motor. Each controller is pre-programmed with patented pump specific software. Controllers are specifically designed to work with all configurations of centrifugal pumps, matching pump output to varying system conditions while protecting the pump, the motor and the pumping system.
Packaged Hydrovar
NOTE: Pressure Transducer, fused disconnect, complete wiring and conduit included.
Pump Mounted Variable Speed Controller
Variable Speed Control – Hydrovar®
C US
UL®
®
C US
PAGE 17
Commercial Watergoulds Water technology
Wall Mounted VersionIntroduction
The Aquavar® CPC (Centrifugal Pump Controller) from CentriPro incorporates the latest state-of-the-art Aquavar technology. The Aquavar CPC is a variable frequency drive and pump specific PLC in one compact unit, that will vary the speed of the motor to maintain a consistent pressure, flow, temperature or level. Here are just a few of the features and benefits of this innovative product:
• Start-up “wizards” expedite the programming process.
• Removable control panel/display.
• Fully backlit display with large text makes the control pad easy to read.
• Transducer assembly (0-300 psi) included for constant pressure.
• Protect the pump from cavitation, dead head and blocked suction.
• Protect the motor from short circuit, phase loss, overload, undervoltage, overvoltage.
• Input choke reduces harmonics and provides 3-5% impedence line reactor.
• EMC/RFI filters reduce drive noise emissions and interference.
• MODBUS® compatible. MODBUS is standard protocol with SCADA networks.
• Capable of controlling up to 3 fixed speed pumps, with one drive.
• Multipump control for up to 4 pumps, without additional PLC’s or control panels.
• Auto lead/lag and switching control built in.
ratings and Enclosures• NEMA 1 (indoor use) standard. Other enclosures available upon request.
• 1 – 200 HP (frame R1 – R6) wall mounted. 250 – 550 HP (frame R7 and R8) floor mounted.
• Ambient temperature 5º F – 104º F. Higher temperatures can be achieved using optional enclosure upgrades and derating factor for up to 122º F.
• At altitudes from 0 to 3300 feet rated current is available, for every 328 feet above 3300 feet the current must be derated 1%. Maximum 6600 feet (consult factory above 6600 feet).
• Relative humidity lower than 95% without condensation.
• UL 508C compliant. UL, cUL, CE approved.
Electrical CharacteristicsInput Power
• 3 phase 380 V to 480 V +10%/-15%
• Frequency 48 to 63 Hz
• 1 phase 208 V to 240 V +10%/-15%
• .98 power factor
• 3 phase 208 V to 240 V +10%/-15%
Output Power
• 3 phase from 0 to Vsupply (All motors must be 3 phase.)
• 0 to 60 Hz frequency
Variable Speed Control – Aquavar® CPC
PAGE 18
Commercial Watergoulds Water technology
Simplex Variable Speed Pump ControllerAquavar SPd Features
• Easy Set-up → Pre-set for submersible or surface motor character-istics. Pre-wired and tested transducer. Touch button pressure set-ting. No complicated menus or electrical programming to cope with. Total set up time including wiring is less than 30 minutes.
• NEMA 3r → Outdoor rated enclosure eliminates the need for separate cover panels required by competitive standard NEMA 1 enclosures. Operating temperature -22º F to 122º F!
• dual Phase Input → UL Listed for either three phase or single phase input (de-rated).
• Filter Pack → Aquavar SPD models with an “F” suffix come com-plete with output filter rated to 1000 feet of motor lead. It is ready to go without having to source and install components from other sources. Programming is also pre-set to 30 Hz minimum to protect motor bearing lubrication required by some motor manufacturers.
• True Motor Match → The Aquavar SPD is already rated for the higher amps typical of higher HP submersible pump start-up. There is no need to oversize the drive as with other units. A 10 HP Aquavar SPD will run a 10 HP submersible pump!
• Transducer → As with all Goulds drives, the pressure transducer is included with the drive so there is no need for separate sourcing and compatibility checks. The transducer is pre-wired and tested, with internal case grounding!
• Full diagnostics → In addition to typical electrical protection and diagnostics, the Aquavar SPD has a full range of pump protection features such as bound pump or motor shut down, low water or loss of prime shut down. These added features require no added input devices.
• remote on/off → Permits external control by timers (irrigation), float or pressure switches (tank draining) or manual control. Dry contact closure required.
• Hand/Auto Option → Allows the drive to be run at full speed without a pressure transducer for longer periods of time as in the case of new well development or system start up. Turning the control back to auto resumes the automatic pressure tracking and control.
• remote Monitoring → External monitors may be connected to the drive for monitoring pump running speed (4-20 mA output based on speed), pump on, and system fault. The fault indicator can also be connected to devices like an auto-dialer. This enables control of pumps and drives in un-manned locations. The 4-20 mA output can be utilized for functions such as an external dosing system, chlorine injection.
• Pressure drop → The reaction time of the drive to pressure drops can be adjusted from the typical 5 PSI drop to as much as 20 PSI. This allows for fewer starts.
• dual Set Point → The Aquavar SPD has the capability to be pro-grammed with two pressure set points. An external contact such as a timer can be used to change between them, so that a booster pump serving both a building and an irrigation system can do both jobs without manual resets.
• No Water restart → The Aquavar SPD has the capability to adjust the time delay in between each “dry well” fault. Adjustable from 10 minutes to 2 hours between each restart. Ideal for low yielding wells.
Variable Speed Controls – Aquavar SPd™
Aquavar SPd models with an “F” suffix are configured for submersible pumps. Models without the “F” suffix are configured for centrifugal pumps.
PAGE 19
Commercial Watergoulds Water technology
Variable Speed Constant Pressure Systems1151AB2, 1AB2 and 2AB2 Aquavar ABII
Controller Features
• Input Power* — 1151AB2 115V +/- 15%, 50/60Hz 1AB2, 2AB2 230V +/- 15% 50/60Hz (controller only)
• Output Power — Up to 230V three phase (based on input voltage). Motor rated for 208-230V, ±10%.
• Maximum Output Current — 4.2 amps – 1151AB2 and 1AB2; 6.9 amps – 2AB2
• Input Controls — Up and down buttons to set pressure.
• Signal Lights — Power on, pump running, inverter stopped, pump stopped, standby, faults/errors.
• Electrical Efficiency — Over 95%
• Protection Against — Short circuit, under voltage, overload, motor temperature, dead heading, run out, suction loss, sensor fault, bound pump, over voltage, static discharge.
• Ambient Temperature — 34º F to 104º F
• Maximum Humidity — 95% at 104º F, non-condensing
• Air Pollution — Avoid mounting in areas with excessive dust, acids, corrosives and salts.
• Approvals —
• Controller Enclosure — NEMA 3R, IP 43 (Rain-tight)
• Mounting — Wall mount with mounting hardware.
• Cooling — Convection with heat sink.
• Transducer — 0.5 - 4.5 VDC with 5 VDC power supply, 100 psi range, 80-inch 3-core cable.
• Input Wire — 5 feet of 14 gauge cable. Cable is pre-wired to controller and junction box.
• Output Wire — 10 feet of 14 gauge cable. Cable is pre-wired to controller and pump motor (when provided).
* Low input voltage may affect motor operation.
Pressure range
Nominal Range — Field adjustable from 20 - 85 psi, total system pressure.
dO NOT SET rEquIrEd SySTEM PrESSurE ABOVE 85 PSI. SEVErE dAMAGE TO PLuMBING COuLd rESuLT.
• Available as a complete booster system with several pump options. See BAQUABII bulletin. Model HMS shown.
WARNING
C US
UL®
Variable Speed Controls – Aquavar ABII
HMS Pump
1151AB2, 1AB2 and 2AB2
Distributor Information
Xylem Inc. manufactures professional grade pumps, controls and accessories for commercial and residential
sump, effluent and wastewater applications. Our nationwide distribution and U.S.-based manufacturing facilities
can get you the products you need quickly. Backed by over 160 years in the pump business and the Goulds
Water Technology customer support and service that is second to none.
Xylem Inc. is a global leader in the water technologies market. The Goulds Water Technology product portfolio
includes submersible and line shaft turbine, 4” submersible, jet, wastewater and centrifugal pumps for residential,
agriculture and irrigation, sewage and drainage, building services, commercial and light industrial use.
For more information visit www.gouldswatertechnology.com or www.centripro.com.
Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. CentriPro, Aquavar, Aquavar ABII, Aquavar SPD, AquaForce, CentriGuard, GT Irri-Gator and PrimeLine are trademarks of Xylem Inc. or one of its subsidiaries. Modbus Protocol is a registered trademark of Modicon Inc.© 2012 Xylem Inc. BRGLCAR R1 March 2013