setpoint device including power supply Kleinförderbänder VR-24-SW-11 advantages: manual presetting of speed for EC motor types (brushless motor types) Faulhaber 2232-BX4-SC, 2250-BX4-SC, 3242-BX4-SC, 3268-BX4-SC with integrated speed controller flexible speed control of conveyors up to 110% of nominal speed simple wall or table fastening protection class IP 67 plug-in connectors (opening of housing not necessary)

Upload: others

Post on 11-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PSU-4341-03 Datenblatt Stand 2013-07-03 · 2016-12-15 · EN 55011, EN 55022 Class B Harmonic input current, fulfills EN 61000-3-2 Immunity: EN 61000-6-1 / -2 Electrostatic discharge

setpoint device

including power supply

Kleinförderbänder

VR-24-SW-11

advantages:

• manual presetting of speed for EC motortypes (brushless motor types) Faulhaber2232-BX4-SC, 2250-BX4-SC, 3242-BX4-SC, 3268-BX4-SC with integrated speed controller

• flexible speed control of conveyors up to110% of nominal speed

• simple wall or table fastening

• protection class IP 67

• plug-in connectors(opening of housing not necessary)

Page 2: PSU-4341-03 Datenblatt Stand 2013-07-03 · 2016-12-15 · EN 55011, EN 55022 Class B Harmonic input current, fulfills EN 61000-3-2 Immunity: EN 61000-6-1 / -2 Electrostatic discharge

Kleinförderbänder

technical data:

© v

ett

er

Ban

d I D

B-V

R-2

4-S

W-1

1 /

09

201

5u

lric

hw

erb

eag

en

tur.

de

www.vetter-band.de

Tel. +49-7348-96 74 85-0Fax +49-7348-96 74 [email protected]

Vetter Kleinförderbänder GmbHEinsteinstraße 889179 Beimerstetten

• input voltage : 230 V AC

• output voltage : 24 V DC

• max. continuous output current: 2 A

• setpoint output voltage : 0-11 V DC (manually by keypad)

• control of conveyor speed : 0% - 110%

presetting of speed for EC motor types (brushless motor types) Faulhaber

2232-BX4-SC, 2250-BX4-SC, 3242-BX4-SC, 3268-BX4-SC with integrated speed controller

(not applicable for brushed DC motors!)

VR-24-SW-11setpoint device including power supply

Page 3: PSU-4341-03 Datenblatt Stand 2013-07-03 · 2016-12-15 · EN 55011, EN 55022 Class B Harmonic input current, fulfills EN 61000-3-2 Immunity: EN 61000-6-1 / -2 Electrostatic discharge

Assembly Instructions

Bocube consists of few parts, so it can easily be

mounted by hand.

Open it by means of a screwdriver (size 3).

The hinge is light levered open.

also see video:

https://www.youtube.com/watch?v=XDJkjj3PK7E

Page 4: PSU-4341-03 Datenblatt Stand 2013-07-03 · 2016-12-15 · EN 55011, EN 55022 Class B Harmonic input current, fulfills EN 61000-3-2 Immunity: EN 61000-6-1 / -2 Electrostatic discharge

Connection Plan VR-24-SW-11

VA-1

0-INT

analog

boa

rd

+ + - -OUTPUT 24V

DC/2:5A

DC OKAdjust (23-29V

)

N N L1 L1

INPUT 100-240V / 50-60Hz

Pin assignment outside

Pin assignment inside

1

2 3

4

5

1

2 3

4

5

brown

yellow

green

grey

bridge

white

grey

gree

n

yello

w

brow

n +

pink

pinkwhite

123456

UpUm

otGND

UnsollDIRFG

12

3 4

5

12

3 4

5

Keypad integratedin top cover

Connecting diagram Connecting diagram

Brushless DC-Servomotor with integrated speed controllere.g.- 22xx BX4 SC- 32xx BX4 SC

Power plug100-240 V, 50-60Hz

Pin assignment connector 1"connection for conveyor"

Pin assignment connector 2"connection to customer's control"

Plug 1 Plug 2

Page 5: PSU-4341-03 Datenblatt Stand 2013-07-03 · 2016-12-15 · EN 55011, EN 55022 Class B Harmonic input current, fulfills EN 61000-3-2 Immunity: EN 61000-6-1 / -2 Electrostatic discharge

Connection Plan VR-24-SW-11

output 0-11 VDCAdjustment by integrated keypad or by external analog signal

connected to pin 3 of connector 2 "connection to customer's control"FG output motor (6 pulses per revolution)

connected to pin 4 of connector 2 "connection to customer's control"DIR input (direction of rotatation)

supply voltage (for conveyor)

5

4

analog signal

3 open

open

+24 VDC

2 groundGND

1

Pin assignment connector 1 (outside)"Connection for conveyor"

Pin assignment connector 2 (outside)"Connection to customer's control"

Keypad/ analog signal Pressing membrane key „+" and „-" simultaneously for at least 4 s sets controller from „keypad-speed-control" to „external analog-signal-speed-control" (pin 5 of connector 2 “connection to customer´s control” Pressing mebrane key „+" or „-" once changes the analog signal in steps of 3% in the range from 0 to 11 VDC.

input 0-11 VDC, external analog signal

connected to pin 3 of connector 1 "connection for conveyor"FG output motor (6 pulses per revolution)

connected to pin 4 of connector 1 "connection for conveyor"DIR input (direction of rotation)Delivery status: bridge mounted to connect pin 4 and pin 2 (GND) Changing direction of rotation:a) Change bridge to connect pin 4 and pin 1 (+24VDC)b) Remove the mounted bridge and provide external signal (GND or 24 VDC)

supply voltage (for conveyor)

GND

+24 VDC1

ground2

3

open

open

4

analog signal5

Page 6: PSU-4341-03 Datenblatt Stand 2013-07-03 · 2016-12-15 · EN 55011, EN 55022 Class B Harmonic input current, fulfills EN 61000-3-2 Immunity: EN 61000-6-1 / -2 Electrostatic discharge

Professional Power

Specification Sheet

PSU-4341-03

60W / 24V / 2,5A

Seite 1 von 2 PSU-4341-03_Specification-Sheet_as of 2013-07-03.doc

inpotron Schaltnetzteile GmbH Phone +49 7731 9757-0 Sitz der Gesellschaft ist Hilzingen Geschäftsführer Hebelsteinstraße 5 Fax +49 7731 9757-10 HRB 541493 Amtsgericht Freiburg Hermann Püthe

78247 Hilzingen E-Mail [email protected] Ust-ld. Nr. DE189711386

Germany Internet www.inpotron.com Zoll-Nr. 4899652

• Wide range input

• High power density with minimized losses

• Efficiency up to 91,5%

• Tu up to +70°C, without derating

• International approvals

• Protection Class II, no grounding conductor

required

• Simple mounting and wiring

• Very compact size with optimized aeration

• Dynamic overload

(150% of rated current up to 2,5 seconds)

Input:

Rated voltage: 100-240V~, 50-60Hz

Operational voltage: 85-264V~, 47-63Hz (100-375V DC)

Wide range power supply, no ranging necessary.

Input current: < 0.7A @ Uin = 230V~

< 1.3A @ Uin = 100V~

Complies with EN61000-3-2 (Harmonic input

current)

Fuse: Internal in power supply, T4AH/250V, not

operator accessable.

Branch circuit breaker for operation in North-America (ANSI): 20A (max.)

Branch circuit breaker for operation in Europe (IEC): 16A (max.)

Efficiency (typical):

Uin =230V~ 91.5% @ nom. load losses (typ.) 5.6W

Uin =115V~ 90.0% @ nom. load losses (typ.) 6.7W Uin =100V~ 88.0% @ nom. load losses (typ.) 8.2W

Reliability:

Load life of capacitors: All electrolytic capacitors are dedicated 105°C

long life types with at least 50.000 hours load

life @ TA = 50°C (Ambient temperature of

power supply)

Safety and 100% factory tested

functional testing:

Output: U1

Output voltage DC: 24.0V DC nominal

Accuracy: ±1% over complete load and input voltage range

Adjustment range: 23.0 – 29.0V DC (minimal range)

Output current (max.): 2.5A continuous (@ 24V DC)

3.15A (125 % of nominal load)

for max. 7 seconds 3.75A (150 % of nominal load)

for max. 2.5 seconds

Output current (min.): 0A

Ripple voltage (< 20MHz): ≤ 40mVSS, measured at limited BW;

20MHz, 50Ohm terminated

Current limiting (typ.): 2.7A continuous

5.0A dynamic

Startup:

Startup time: typ. 400ms

Over complete input voltage range

Startup duration: depends on load, typ. 5-10 ms

Startup with cap. load: up to 8.000uF and nominal load

Safety:

Output: Safety extra low voltage (SELV)

IEC60950-1:2005, EN60950-1:2006 + A11:2009

Class of protection: II

Enclosure type: IP 20

Leakage current: max. 0.25 mA, @ 47-63Hz and max. 264V~

Operating Conditions:

Operating temperature: -20°C to +70°C, without forced air

Cooling

Load derating: Functional not necessary.

For extend long term reliability: 2%

of nominal load per degree above +60°C to max. +70°C

Storage temperature: -25°C to +85°C

Humidity: max. 95% r.H., no condensation

Altitude: max. 2000m (6500ft) above sea level

Branch circuit breaker for operation in North-America: 20A Branch circuit breaker for operation in Europe: 16A

EMV in conformance to CE

Emission: EN 61000-6-3 / -4

EN 55011, EN 55022 Class B

Harmonic input current, fulfills EN 61000-3-2

Immunity: EN 61000-6-1 / -2

Electrostatic discharge 8 kV contact discharge Level 4

EN61000-4-2 15kV air discharge

Electromagnetic RF field 10V/m Level 3

EN61000-4-3

Burst 4kV AC mains Level 4

IEC1000-4-4 2kV output, capacitive coupling Level 3

Surge 2kV symmetrical, Insulation class 4

EN61000-4-5 protection class II, no asymmetrical testing

Conducted disturbance 10V, 150kHz to 80MHz Level 3

EN61000-4-6

AC Main voltage EN61000-4-11 and interruptions

Page 7: PSU-4341-03 Datenblatt Stand 2013-07-03 · 2016-12-15 · EN 55011, EN 55022 Class B Harmonic input current, fulfills EN 61000-3-2 Immunity: EN 61000-6-1 / -2 Electrostatic discharge

Professional Power

Specification Sheet

PSU-4341-03

60W / 24V / 2,5A

Seite 2 von 2 PSU-4341-03_Specification-Sheet_as of 2013-07-03.doc

inpotron Schaltnetzteile GmbH Phone +49 7731 9757-0 Sitz der Gesellschaft ist Hilzingen Geschäftsführer Hebelsteinstraße 5 Fax +49 7731 9757-10 HRB 541493 Amtsgericht Freiburg Hermann Püthe

78247 Hilzingen E-Mail [email protected] Ust-ld. Nr. DE189711386

Germany Internet www.inpotron.com Zoll-Nr. 4899652

Protection and Monitoring:

Over-voltage protection: Yes, U1 limited to max. 35V DC

Function In case of a fault in the power supply, e.g. failure

of the voltage regulation, the output voltage will rise up to appr. 35V DC. In this condition an

independent monitoring will shut-down the

output. This protection is reset by disconnecting

the power supply from AC mains. After a delay of approx. 1 minute the reset is finished and the

power supply can start again. The delay time

depend on former AC supply voltage. If the Fault

is not eliminated the shutdown will start again.

Current limiting: Yes, output is short circuit save

In case of overload the output voltage will be reduced down to approx. 17V DC below this the

power supply will enter hicc-up mode to protect

power supply and load from over temperature or

burning.

No load operation: Yes, indefinite no load safe

Overload protection: Yes

Inrush current: < 40A @ Uin = 264V~,

Cold and warm start and after AC mains

interruptions.

Hold-up time: 100ms @ Uin = 230V~

15ms @ Uin = 115V~

Temperature controlled Yes

power limiting:

Operating indicator: Yes, green LED on front side.

High-voltage test: Yes, type test according to standards:

3.000V / 50Hz primary – secondary

100% testing in 3.000V / 50Hz primary – secondary

series production:

Safety Approvals:

Information technology equipment:

IEC 60950-1:2005 + A1:2009 EN 60950-1:2006 +A11:2009 + A1:2010 +A12:2011

UL 60950-1:1st Edition

CSA C22.2 No. 60950-1-03

Industrial control equipment:

UL 508 (used as reference only)

Safety of machinery: EN 60204

Electronic equipment for

use in power installations:

EN 50178

Electrical apparatus for

explosive gas

atmospheres:

CAN/CSA-C22.2 No. 60079-0:07

CAN/CSA-E60079-15:02

UL Std. No. 60079-0:09 UL Std. No. 60079-15:09

Class I, Div. 2, Groups A, B, C and D, Temperature code T4

Class I, Zone 2, (A)Ex nA II T4

Remark: For use in explosive gas atmospheres the power supply had to be

mounted in an enclosure of type IP54 or better, e.g. the enclosure of the end use

equipment.

Warning: - Explosion hazard – Substitution of components may impair

suitability for class I, division 2.

Warning: - Explosion hazard – Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous.

EMC + Low Voltage Directive / CSA-NRTL/C

All technical data are specified at Uin = 230V~ / 50Hz, +25°C ambient,

nominal load and after 10 min @ nominal load unless otherwise noted.

Dimensions: DIN Rail Power Supply In Plastic Housing

AC mains on bottom of front cover, output on top.

Dimensions (D x W x H): 104.5 x 44.8 x 75 mm

Weight: ca. 250 Gramm

Wiring: Spring clamp terminals. No tools required.

Safe contact without maintenance.

Primary: 2 x L1 / 2 x N on bottom

Secondary: 2 x U1 / 2 x GND on top

Cross section of wires

Stranded wire: 0.3...2.5mm² (AWG22 – 14) Solid wire: 0.3...2.5mm² (AWG22 – 14)

Mounting: Snap-on element for fixing on DIN rail according to EN 50022-35.

Use rails TS35/7.5 or TS35/15

Tight fixing on DIN rail.

All information meet the technical design at time of printing and were therefore

not binding. inpotron reserves the right for changes at any time and without

giving any information.