psa350man

4
The PSA 350-serie power supply and amplifier is designed to amplify radio and TV signals for distribution in a medium-sized network. PSA 350 with an additional RA-15 plug in module can also be used for interactive systems. The power supply accepts 117 and 230 VAC. Like all other Naval products, the PSA 350 series is designed to meet the special requirements of world-wide marine use. See overleaf for further details of specific applications. Power supply and Amplifier PSA 350-serie Technical manual 5011

Upload: pepepopo2

Post on 28-Dec-2015

34 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: psa350man

The PSA 350-serie power supply and amplifier is designed to amplify radio and TV signalsfor distribution in a medium-sized network. PSA 350 with an additional RA-15 plug inmodule can also be used for interactive systems. The power supply accepts 117 and 230VAC. Like all other Naval products, the PSA 350 series is designed to meet the specialrequirements of world-wide marine use. See overleaf for further details of specificapplications.

Power supply and Amplifier PSA 350-serieTechnical manual

5011

Page 2: psa350man

Power supply and Amplifier page2/4 Vers.1.0 00-12-13PSA 350-1/2 Technical manual

T.B.

AV-15

NC

CUT OUT RELAY

FUSE:400mA

ATT. EQ.PSA 350

GAINAM-20 0.1-27 MHZ

EQ

LIN E IN15 V D C O U TM A X 3 00 m A

23 0/117 VA CIN

LIN EO U T

V TR IN C U T O U T

O PTIO N A LO U TP U T

A B

20 1 17 0 P SA -3 50 A M -F M -TV A M PL .+V T R IN P U T20 1 17 1 P SA -3 50/1 A M -FM -TV A M PL IF IE R20 1 17 2 P SA -3 50/2 FM -TV A M PL .+ IN TE R A C TIV E U N IT

T TT TT T

AV-15 AM -20TO-*/0A AM-20TO-*/0A RA-15

20 1 17 0-0 P S A -35 0-0 FM -TV A M P L. T O TTO-*/0A

OT C O ther u n its can on ly b e ch ang ed afte r fa cto ry ap prova l.

ART.NO NAME TYPE POS.A POS.BAVAILABLE VERSIONS

F u se T 16 0m AF u se T 31 5m A

230V AC117V AC

Block and connection diagram PSA 350

Coax stripping Connecting PSA 350

The PSA-350 equipment shall be installedby approved/qualified installer. For class IIinstallation, power cord must be changed.The power supply in PSA-350 is equippedwith CE approved powercable as standard.

The in, out and VTR parts are normallymounted with a F-female adapter, to use astandard F-male as per this sketch.

In, out and VTR can also be 5/8"-24 NEFfemale without the F-connector adapter.

Page 3: psa350man

Power supply and Amplifier page3/4 Vers.1.0 00-12-13PSA 350-1/2 Technical manual

Vin1

GN

D2

Vout3

Q 1

C 3 C 2 C 1

FU S E 2AC 230V

O U T24V D C

FU S E 1

FU S E 1: T160m A FU S E 2: T315m A

AC 110V

T1

D 1

Schematic PSA 350

Schematic powersupply PSA 350

Mechanical PSA 350

5011A

Page 4: psa350man

Power supply and Amplifier page4/4 Vers.1.0 00-12-13PSA 350-1/2 Technical manual

All specifications stated are subject to change without notice

Höjdrodergatan 18, SE-212 39 Malmö, SwedenTel. +46(0)40-29 20 45 Fax +46(0)40-18 74 13

E-mail: [email protected] www.naval.se

Diagnostic check PSA 350Use a voltmeter to measureoutput voltage and to checkstatus of the fuses. NOTE! This check is onlyrelevant for PSA 350 notPSA 350-1/2