prx u, prx w, prv u, prv w - haug...haug gmbh & co.kg friedrich-list-straße 18 d-70771...

12
PRX U, PRX W, PRV U, PRV W Operating instructions Angular electrode and U-shaped electrode Static Line Operating instructions Angular electrode and U-shaped electrode

Upload: others

Post on 30-Jan-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

  • PRX U, PRX W, PRV U, PRV W

    Operating instructions Angular electrode and

    U-shaped electrode

    Sta

    tic L

    ine

    Ope

    ratin

    g in

    stru

    ctio

    ns

    Ang

    ular

    ele

    ctro

    de a

    nd U

    -sha

    ped

    elec

    trod

    e

  • Operating instructions angular electrode and U-shaped electrode

    Winkel- und U-Elektroden v02gb

    Page 3

    Types: PRX U; PRX W PRV U; PRV W Keep in a safe place for future reference!

    Contents 1. Notes on operating instructions 5. Remedy of defects 2. Safety 6. Maintenance and repairs 3. Installation 7. Technical data 4. Application

    1 Notes on operating instructions In these operating instructions, the individual ionizing units are also referred to as "units" or "ionizing units".

    1.1 Pictorial markings used In these operating instructions

    Caution! Important instructions!

    Danger! High voltage! Danger of fatal accidents!

    Switch off the power pack before connecting or disconnecting the coaxial connectors!

    In the operating instructions and on the unit

    Danger! High voltage! Danger of fatal accidents!

  • Operating instructions angular electrode and U-shaped electrode

    Winkel- und U-Elektroden v02gb

    Page 4

    2 Safety The ionizing units of these series are operationally safe, provided that they are operated in accordance with their intended use. In case of misuse, dangers may result: - for life and limb of the operator, - for the unit and other assets. Also note Chapter 3.1 (Important installation notes).

    For operators with heart pacemakers special instructions should be requested from the manufacturer!

    During operation of the units, small quantities of ozone will form. In order to ensure adherence to maximum permitted ozone concentrations at the workplace, make sure that the workplace is ventilated sufficiently during operation of the units.

    The operator of the units must take care to ensure sufficient ventilation during operation!

    2.1 Intended use Ionizing units generate positive and negative ions. Their purpose is the elimination of electrostatic charges (e.g. in paper, films and foils, textiles, glass, plastics etc.). HAUG power packs only must be used for supplying the high voltage to the units.

    Do not install or use the units in areas subject to explosion hazards.

    For reasons of safety, unauthorized conversions and modifications of the unit are not permitted. The installation and operating conditions indicated in these Operating Instructions must be adhered to.

    2.2 Danger sources Defective high-voltage plugs and cables may lead to danger of electric shocks. Shut down the unit immediately in case of visible damage and suspected electrical defects.

    Danger! High voltage! Danger of fatal accidents!

    Switch off the power pack before connecting or disconnecting the coaxial connectors!

  • Operating instructions angular electrode and U-shaped electrode

    Winkel- und U-Elektroden v02gb

    Page 5

    2.3 Operator qualifications The unit may be installed and put into operation by trained electricians only or by authorized and persons informed about the potential dangers. The above mentioned persons must have read the operating instructions and must follow the instructions, notes and safety advice.

    3 Installation The unit may be installed by trained electricians only and by authorized persons informed about the potential dangers. The above mentioned persons must have read the operating instructions and must follow the instructions, notes and safety advice.

    3.1 Important installation instructions The operation of the unit is not affected by the position in which it is installed.

    Do not connect the units to the power pack until installation is completed.

    Switch off the power pack before connecting or disconnecting the coaxial connectors!

    3.2 Ionizing units The numerals refer to the illustration at the end of these instructions. - Example for ionizers. Most favourable distance ionizing unit - material

    approx. 20 - 30 mm, min. 10 mm, max. 80 mm. Distance B to grounded machine part always greater than distance A. Install ionizer so that no machine parts are located behind the material. Never attach metal holders above the ionizing needles. Install high-voltage cables without kinks. Smallest bending radius 50 mm.

    - Examples of holders.

  • Operating instructions angular electrode and U-shaped electrode

    Winkel- und U-Elektroden v02gb

    Page 6

    4 Application The unit may be put into operation by trained electricians only or by persons instructed in the potential dangers. The above mentioned persons must have read the operating instructions and must follow the instructions, notes and safety advice.

    The operator of the units must take care to ensure sufficient ventilation during operation!

    Conditions: The power pack and the ionizing unit must be connected correctly. Ionizing units, in combination with HAUG power packs, are intended for the removal of electrostatic charges (e.g. from paper, films and foils, textiles, glass, plastics etc.). Example: Figure 1: Unloading of weighing vessels of laboratory balances Figure 1

  • Operating instructions angular electrode and U-shaped electrode

    Winkel- und U-Elektroden v02gb

    Page 7

    5 Remedy of defects Any remedy of defects must be carried out by trained electricians only. The above mentioned persons must have read the operating instructions and must follow the instructions, notes and safety advice. In case of defects regarding the power pack and the ionizing unit, please check for correct installation first. If this does not solve the problem, please return the power pack together with the ionizing unit for examination.

    Danger! High voltage! Danger of fatal accidents!

    Switch off the power pack before connecting or disconnecting the coaxial connectors!

    6 Maintenance and repairs

    Danger! High voltage! Danger of fatal accidents!

    This unit does not include any parts which can be maintained or repaired by the operator. Should the unit prove defective or if a defect is suspected, switch off unit immediately and secure against subsequent reuse.

    6.1 Ionizing units Clean at intervals of no more than 14 days using the special cleaning brush or the special cleaning system (see Section 6.2 Accessories).

    6.2 Accessories PRX retaining plate 10.0400.001 Holder for angular electrode 10.0269.000 Holder for "U"-shaped electrode 10.0371.000 Special cleaning fluid 10.7220.000 Special cleaning brush 10.7218.000 Special cleaning system 10.7218.001 Circular brush for special cleaning system X – 6822

  • Operating instructions angular electrode and U-shaped electrode

    Winkel- und U-Elektroden v02gb

    Page 8

    7 Technical data

    7.1 Supply voltage The ionizing units are provided with high voltage from HAUG power packs.

    7.2 Ambient conditions Ambient temperature: Rated application range +5 °C to +45 °C Extreme range for storage and transport -15 °C to +60 °C Humidity: Rated application range 20 % to 65 % RH Extreme range for storage and transport 0 % to 85 % RH

    7.3 Dimensions Type Shape Cross-section

    PRX W Angle (90°) 14 x 14,5 mm PRX U “U” 14 x 14,5 mm PRV W Angle (90°) 15 x 16 mm PRV U “U” 15 x 16 mm High tensions lead 2 m

  • A

    B

    ~ 20 - 30 mm

  • r > 50 mm

  • D – 0219 16.08.04

    made by

    HAUG GmbH & Co.KG

    Friedrich-List-Straße 18D-70771 Leinfelden-Echterdingen Telefon 07 11 / 94 98 - 0Telefax 07 11 / 94 98 - 298

    www.haug.deE-Mail: [email protected]

    HAUG Biel AG

    Postfach 52 CH-2500 Biel/ Bienne 6Johann-Renfer-Strasse 60 CH-2500 Biel/ Bienne 6Telefon 0 32 / 3 44 96 96Telefax 0 32 / 3 44 96 97

    www.haug.deE-Mail: [email protected]

    Contents1 Notes on operating instructions1.1 Pictorial markings used

    2 Safety2.1 Intended use2.2 Danger sources2.3 Operator qualifications

    3 Installation3.1 Important installation instructions3.2 Ionizing units

    4 Application5 Remedy of defects6 Maintenance and repairs6.1 Ionizing units6.2 Accessories

    7 Technical data7.1 Supply voltage7.2 Ambient conditions7.3 Dimensions

    Illustration