Belzona can provide solutions to common problems found in Substations including:
SF6 leaks
Transformer Leaks Insulator Damage
Facilities Maintenance
Transformer Leaks
Conventional Solutions
Clamps - Costly and not always available for geometry
Welding - Hot work / draining issues – not online repair
Conventional putty - Poor adhesion & compressive strength
• Water contamination• Internal and external
corrosion• Impact and abrasion
damage• Coating Breakdown
Due To :
Company
Problem
Application Details
Leaking Transformer Fins
Wind Farm, UK
Lower edge of fins on oil filled transformer corroded and starting to leak. Problem caused by sheep rubbing against fins, damaging paint system.
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-1. Pre-formed doubler plates were bonded over the corroded areas after manual surface preparation
Company
Problem
Application Details
Leaking Transformer Flanges
Power Plant, West Tennessee USA
Leaking flanges created an environmental hazard and the transformer could not be drained for repair.
The application was carried out using a modified Belzona Know-How System Leaflet GSS-4, temporarily stopping the leak with Belzona1831 before encapsulating the flange with a Belzona 2000 series elastomer.
Company
Problem
Application Details
Leaking Transformer Fins
National Grid, UK
Oil Leaks at bolted flanges resulting in contamination and slip hazards
Application was carried out in accordance with Belzona Know-How System Leaflet VPF-11a. All works were carried out without the need to drain down the transformer
Product
Features
Benefits
Featured Product
Belzona 1831
Optimised for adhesion to less than optimally prepared surfaces, displaces oil and water
Reduced need for optimal preparation of surfaces, allowing easier and effective repairs in-situ. No necessity to drain down equipment prior to repair.
Adhesion of Belzona® 1831 on Oily Steel
0 500 1000 1500 2000 2500
Dry
Oily
Tensile Shear Adhesion, psi
Manually abraded steel
Grit-blasted steel
• No hot work required• On-line repair - no need to drain• No galvanic effects• High adhesion to a huge range
of materials• Surface tolerant• High compressive strength• No shrinkage• Simple and safe to use• Environmentally friendly• Rapid turnaround• Turnkey Solution
A Cost Effective Alternative Solution to Sealing Leaking Transformers
Belzona Solutions for Transformer Oil Leaks
SF6 Leaks
Conventional Solutions
New gasketing - Shutdown of equipment requiredMastic Sealant - Ineffective and short termConventional putty - Poor adhesion &
compressive strength
• Water contamination• Internal and external
corrosion• Aging of gaskets• UV Deterioration of mastics
Due To :
Company
Problem
Application Details
Leaking Switchgear Flanges
Electric Distributor, Australia
SF6 leaking through flanges due to failure of original mastic sealant
Following removal of the failed system by grit blasting, a Belzona 1000 series system was used to seal the flange joint.
Leak detection proved success of the repair and resulted in a further 515 flanges being sealed.
Company
Problem
Application Details
SF6 Leaks through Flanges
Hydroelectric facility, BC Canada
Leaking joints were resulting in regular refilling of the SF6 gas.
Application was carried out in accordance with Belzona Know-How System Leaflet GSS-4. Injection methods were used to force the Belzona 2000 series Elastomer between the flanges. The repair has been in service for over 10 years and numerous repairs have been done.
Company
Problem
Application Details
SF6 Leaks on Circuit Breakers
Power Company, UK
SF6 leaks at porcelain insulator bush seal to circuit breaker
After completion of surface preparation to both the aluminium and porcelain the junction was sealed using the fast curing Belzona 2311 system.
Product
Features
Benefits
Featured Product
Belzona 2211 MP-Hi-Build Elastomer
Elongation under ASTM D412 is typically 700% and in addition Belzona 2211 has excellent adhesion
Being optimised for flexibility to bridge moving surfaces whilst maintaining high adhesion allows the system to absorb small movements of flanges etc without loss of sealing
• No requirement for Depressurisation
• High adhesion to a huge range of materials
• Surface tolerant• Flexible• High compressive strength• No shrinkage• Simple and safe to use• Environmentally friendly• Rapid turnaround• Turnkey Solution
A Cost Effective Alternative Solution to Sealing Leaking SF6 gas
Belzona Solutions for SF6 Leaks
Porcelain Insulator Damage
Conventional Solutions
Replacement - Lead Time IssuesConventional putty - Poor adhesion
• Rough Handling• Impact Damage• Vandalism• Flashover
Due To :
Company
Problem
Application Details
Repair of Broken Insulators
Power Distribution company, France
Damage to insulator preventing safe performance
Moulds were made for the Insulators using Belzona 2200 series Elastomers, before casting and bonding the new profile using Belzona 8111
Company
Problem
Application Details
Damage to Insulator Bushings
Power Station, Egypt
The insulators had been cracked and broken and were not functioning correctly
The application was carried out in accordance with a modified version of Belzona VPF-1 & -2. Original profiles were restored with a Belzona 1100 series system and a smooth top surface created using Belzona Ceramic Coatings
• No hot work required• In-situ repairs• High adhesion• Surface tolerant• High dielectric strength• High compressive strength• Water shedding• Simple and safe to use• Environmentally friendly• Rapid turnaround• Turnkey Solution
A Cost Effective Alternative Solution to Repairing Damaged Insulators
Belzona Solutions for Porcelain Insulators
Facilities Maintenance Problems
Conventional Solutions
Tarpaulin - Temporary solutionRe-Roofing - Lead Time and Disruption issuesConcrete repairs - Cannot be
feather edged, lengthy repair
• Leaking Roofs• Concrete Damage• Slips, Trips and Falls
Due To :
Company
Problem
Application Details
Spalled Concrete
Power Station, UK
Severe spalling of the electricity pylon concrete support columns accelerated by the acidic atmosphere generated by local industries
Belzona 4000 series lightweight repair material used to rebuild the damage without the use of shuttering
Company
Problem
Application Details
Roofing leaks
Nuclear Power Plant, Maryland USA
Roof leaks exacerbated by multiple roof penetrations and failure of existing roofing protection
Application was carried out in accordance with Belzona Know-How System Leaflet RPA-1.
Company
Problem
Application Details
Slip Problems
Power Station, UK
Slippage on steps when wet causing health and safety concerns
Belzona 4000 series grip system applied to provide positive grip in wet, icy and oily environments improving safety
• No hot work required• In-situ repairs• High adhesion• Surface tolerant• Local or Full Repairs possible• Immediate Leak Sealing• Emergency and Long Term
repairs possible• Simple and safe to use• Environmentally friendly• Rapid turnaround• Turnkey Solution
A Cost Effective Alternative Solution to Facilities Maintenance Problems
Belzona Solutions for Facilities Maintenance
Belzona provides these solutions to many International Organisations:
Transformer Leak Sealing
SF6 Gas Leak sealing in electrical switchgear
Insulator Repairs
Facilities Maintenance