Protection Protection is the key to maintained plant life and operating conditions. With Merlin Gerins' expertise in electrical distribution it is not surprising that protection of electrical circuits are foremost in mind. To compliment the wide selection of circuit breakers, Merlin Gerin offer a modular fuse solution for differing levels of protection. Another area of focus in todays’ changing climate is lighting protection. There are 3 billion lightning strikes around the world each year exposing critical plant to danger, why take that risk? Consider modular surge protection from Merlin Gerin. Electric lighting is expensive, so efficient control is key to reducing bills whilst still maintaining the correct conditions. Government incentives also provide guidance and encouragement to employ energy efficient solutions. Merlin Gerins’ modular solution to lighting control features on the government supported Energy Technology List. This can allow the end user to claim Enhanced Capital Allowance, in addition to reducing running cost. Measurement and metering The government implementation of the Climate Change Levy has had a significant impact on utility costs. This places the incentive on the end user to measure and monitor usage and implement energy efficient technology where required. Programmable control A flexible solution is essential in today’s changing world, a control solution that can change with the requirements of the occupant of the buildings. With simple, intuitive solutions Merlin Gerin modular time management controls provide all the flexibility a system needs, in a user friendly package. New to the Merlin Gerin range is the innovative ITM multifunction time switch, a single device that can apply no less than nine functions. A true ‘all-in-one’ product with programming simplicity. Guidance is provided within the Building Regulations (2001) approved document part L. Guidance and recommendations are given to building owners or occupiers to enable at least 90% of annual energy consumption to be accounted for, thus enabling the implementation of energy efficient technologies. Merlin Gerin modular solutions create a window through the clouds of confusion. Lighting control In commercial and industrial premises the correct level of lighting is essential to maintain a safe and comfortable working environment. This balance is difficult to achieve as there is often too much electric lighting provided rather than too little. Let yourself be guided by Merlin Gerin modular solutions

Upload: others

Post on 14-Mar-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

ProtectionProtection is the key to maintained plant life andoperating conditions. With Merlin Gerins' expertise inelectrical distribution it is not surprising that protectionof electrical circuits are foremost in mind.

To compliment the wide selection of circuit breakers,

Merlin Gerin offer a modular fuse solution for differing

levels of protection.

Another area of focus in todays’ changing climate is

lighting protection. There are 3 billion lightning strikes

around the world each year exposing critical plant to

danger, why take that risk? Consider modular surge

protection from Merlin Gerin.

Electric lighting is expensive, so efficient control is key

to reducing bills whilst still maintaining the correct

conditions. Government incentives also provide

guidance and encouragement to employ energy

efficient solutions.

Merlin Gerins’ modular solution to lighting control

features on the government supported Energy

Technology List. This can allow the end user to claim

Enhanced Capital Allowance, in addition to reducing

running cost.

Measurement andmeteringThe government implementation of theClimate Change Levy has had a significantimpact on utility costs. This places theincentive on the end user to measure andmonitor usage and implement energyefficient technology where required.

Programmable controlA flexible solution is essential in today’s changing world, a control solution that can change with the requirements of the occupant of the buildings.

With simple, intuitive solutions Merlin Gerin modular time management

controls provide all the flexibility a system needs, in a user friendly

package.

New to the Merlin Gerin range is the innovative ITM multifunction time

switch, a single device that can apply no less than nine functions. A true

‘all-in-one’ product with programming simplicity.

Guidance is provided within the Building Regulations

(2001) approved document part L. Guidance and

recommendations are given to building owners or

occupiers to enable at least 90% of annual energy

consumption to be accounted for, thus enabling the

implementation of energy efficient technologies.

Merlin Gerin modular solutions create a window

through the clouds of confusion.

Lighting controlIn commercial and industrial premises the correct level oflighting is essential to maintain a safe and comfortableworking environment. This balance is difficult to achieve asthere is often too much electric lighting provided ratherthan too little.

Let yourself be guided by Merlin Gerin modular solutions

Modular solutions for building control

Merlin Gerin presents its modularsolution for building control

With products promoting valueengineered solutions that providemore control and benefits toinstallers and end users.

Making the most efficient use of lighting andheating control can make the difference when itcomes to utility costs, an effective metering andmonitoring strategy can point to problem areas.

■Energy saving

■Reduced installation time

■Increased control

With simple installationand configuration letMerlin Gerin guide youwith a modular solution

Schneider Electric are a proudmember of Energy SystemsTrade Association

Manyproductsfeature on theEnergyTechnologyList

Merlin Gerin is a world leader in the manufacture and supply of high, medium and low voltage products for the distribution, protection, control and management of electrical systems. Its quality products, solutions and services are focused on the needs of both the commercialand industrial sectors.

Square D is a total quality organisation and its business is to put electricity to work productively and effectively, protecting people, buildings and equipment. Its low voltageelectrical distribution equipment, systems and services areused extensively in residential and commercial applications.

Telemecanique is a UK market leader and world expert inautomation and control. It provides complete solutions, withit's range of components, Modicon range of high technologyprogrammable controllers (PLCs), multiple fieldbus andethernet communication networks, HMI, motion controlsystems, variable speed drives and communicationssoftware. In addition, it offers power distribution throughprefabricated busbar trunking.

Schneider Electric’s local supportSchneider Electric is committed to supporting its customers at every stage of a project. Our 180 sales engineers, the largestdedicated sales force in the UK electrical industry, operate from 4 customer support centres.

Our sales engineers are skilled at assessing individual requirements and combined with the expert support of our product specialists, will develop the most effective and economical answer taking relevant regulations and standards fully into account.

To access the expertise of the Schneider Electric group, please call 0870 608 8 608. Each customer support centre includesfacilities for demonstrations and training, and presentation rooms fully equipped with audio visual and video, providing excellent meeting facilities.

www.schneider.co.uk

MAY 2003MGD 5321

ScotlandSchneider Electric LtdUnit 11000Academy Business ParkGower StreetGlasgow G51 [email protected]

South WestSchneider Electric Ltd190 Aztec WestPark AvenueAlmondsburyBristol BS32 [email protected]

North WestSchneider Electric Ltd8 Brindley RoadCity Park Business VillageCornbrook Manchester M16 [email protected]

Greater LondonSchneider Electric Ltd2nd Floor408 StrandLondon WC2R [email protected]

Industrial systems and solutions product showroomSchneider Electric Ltd, University of Warwick Science Park, Sir William Lyons Road, Coventry CV4 7EZ

Building systems and solutions product showroomSchneider Electric Ltd, Stafford Park 5, Telford, Shropshire TF3 3BL

Energy and Infrastructure systems and solutions product showroomSchneider Electric Ltd, 123 Jack Lane, Hunslet, Leeds LS10 1BS

Product showrooms

Local customer support centres

Fax 0870 608 8 6060870 608 8 608Nationwide support on one number - call the Customer Information Centre on

member of

.co.uk

Pole 3PModules 2.5In [A] Setting Part No.0.16 0.1 ÷ 0.16 211000.25 0.16 ÷ 0.25 211010.4 0.25 ÷ 0.4 211020.63 0.4 ÷ 0.63 211031 0.6 ÷ 1 211041.6 1 ÷ 1.6 211052.5 1.6 ÷ 2.5 211064 2.5 ÷ 4 211076.3 4 ÷ 6.3 2110810 6 ÷ 10 2110914 9 ÷ 14 2111018 13 ÷ 18 2111123 17 ÷ 23 2111225 20 ÷ 25 21113

Impulse relays

TL, TLI, TLs, TLm, TLc, ETLCEI EN 60669-2.1/2

Impulse relaysauxiliaries

ATL

Modularcontactors

CT, CT manual CEI EN 61095

Pole 1P 2PVn (Vca) 230/240 130 48 24 12 230/240 130 48 24 12Modules 1 1 1 1 1 1 1 1 1 1Impulse TLIn (A) 16 15510 15511 15512 15513 15514 15520 15521 15522 15523 15524

32 15515Changeover TLI (1NO+1Nc)In (A) 16 15500 15502 15503Impulse with indication TLsIn (A) 16 15517 15528 15527Impulse with manual override TLmIn (A) 16 15516Impulse with centralised control TLcIn (A) 16 15518 15526 15525Extension ETLIn (A) 16 15530 15531 15532 15533 15534

32 15505

Auxiliaries Modules Part No.Time delay ATL-T 1 15411Illuminated pushbutton ATL-Z 1 15413Centralised control and indication ATLc+s 1 15409Centralised control and indication ATLc+c 1 15410Step control ATL4 2 15412AccessoriesSet of 10 clips 15414

Pole 1PVn (Vca) 23Contact 1NModulesContactor CTIn (A) 16

25 154063100

Contactor with In (A) 25

4063

Isolation devices

I I with indicationCEI EN 60669-1 (20÷63 A) 230VCACEI EN 60947-3 (40÷125 A) CEI EN 60669-2

Auxiliaries andaccessories for l

Rotary switches

CMB, CMD, CMECEI EN 60947-5-1

S

CC

Auxiliaries for indication Modules Part No.Auxiliary contact 1 15096

Poles 1P 2P 3P 4P 1P 2PModules 1 1 2 2 3 2 4 1 1In (A)

20 15005 15006 15007 15008 15063 1506432 15009 15010 15011 15012 15100 1510140 15019 15020 15023 1502463 15013 15014 15015 15016100 15090 15091 15092 15093125 15057 15058 15059 15060

Selector 1-2 Modules Part No. SCME 1NO+1Nc 3 15122 1Position 2Selector 1>0<2 1CMB 2P 3 pos. 3 15120 SRest at centre 1Selector 0-1-2-3-4 2CMD 1P 5 pos. 3 15121

Motorprotection

P25MCEI EN 6047-2: 15kA

Electrical auxiliariesCEI EN 60947-5

P25Maccessories

Fuseprotection

STI:CEI EN 60947-3

Limiter block Modules Part No.Limiting block 100kA 2.5 21115Remote indicationAuxiliary contactor F+F 0.5 21116Auxiliary contactor O+F 0.5 21117Contactor auxiliary + alarm F+SD-F 0.5 21118Contactor auxiliary + alarm O+SD-F 0.5 21119Contactor auxiliary + alarm F_SD-O 0.5 21120Contactor auxiliary + alarm O+SD-O 0.5 21121Remote trippingMX shunt trip 240/240 V 1 21127MX shunt trip 380/415 V 1 21128MN undervoltage 240/240 V 1 21129MN undervoltage 380/415 V 1 21130

Busbars Part No.For 2 x P25M 21145For 4 x P25M 21146Terminal blocksEnd 21148Blank terminal 21144Insulated connector 21147Insulated enclosureEnclosure 21133AccessoriesIndicator 230/240 V green 21140Indicator 230/240 V red 21142Indicator 380/415 V green 21141Indicator 380/4150 V red 21143

Pole N 1P 1P+NCartridge fuse STIFuse Imax (A)8.5 x 31.5 20 15635 1564510.3 x 38 32 15363 15646Modules 1 1

Conventional timers

Digitaltimers

IHEN 60730

IHPEN 60730

Timers

RT

Delay on energisation ModulesRTA 1Delay on energisation (or impulse)RTC 1Delay on energisationRTB 1Impulse delayRTH 1MultifunctionalRTMF 1Cyclic timerRTL 1

Daily and weekly 24hr and 7 day Modules Part No.1 channel 28 locations 2.5 157201 channel 14 locations 1 158542 channel 42 locations 2.5 15722Daily and weekly 24hr and 7 day + impulse1 channel 42 locations 2.5 157212 channel 42 locations 2.5 15723

Hours 60 min. Modules Part No.1 channel without reserve 3 15338Daily1 channel without reserve 1 153351 channel with 100hr reserve 1 153361 channel with 150hr reserve 3 153652 channel with 150hr reserve 3 15337Daily and weekly 24hr and 7 day1+1 channel with 150hr reserve 3 15366Weekly 7 day1 channel with 100hr reserve 1 153311 channel with 150hr reserve 3 15367Accessories for IH20 jumpers for 15337, 15366, 15367 15341

Modular analoguemetering

AMP, VLTCEI EN 60051, IEC 60414

Modular digitalmetering

AMP, VLT, FREQCEI EN 61010-1

Scale for AMP 16030 Part No.0 - 5A 160310 - 50A 160320 - 75A 160330 - 100A 160340 - 150A 160350 - 200A 160360 - 250A 160370 - 300A 160380 - 400A 160390 - 500A 160400 - 600A 160410 - 800A 160420 - 1000A 160430 - 1500A 160440 - 2000A 16045

Voltmeter VLT Modules Part No.Scale 0 - 300V 4 16060Scale 0 - 500V 4 16061Ammeter AMPScale 0 - 30V direct 4 16029Scale via CT x/5 4 16030

Voltmeter VLT Modules Part No.Scale 0 - 600V 2 15201Ammeter AMPScale 0 - 10A direct 2 15202Scale 40 - 1000 via CT 2 15209Frequency meter FREQScale 20 - 100Hz 2 15208

AnaloguekWh meter

CE. CErIEC 61036

DigitalkWh meter

ME1IEC 61036

ME4IEC 61036

Single phase Modules Part No.ME1 63A 2 17065ME1z 63A 2 17066with resetME1z 63A 2 17067with resetand pulse output

Three phase Modules Part No.ME4 63A 4 17070ME4zrt 40 - 6000A 4 17072with resetand pulsed output

Panel mountinganalogue metering

AMP, VLTCEI EN 60051, IEC 60414

Scale per AMP

Scale for AMP 16004 Part No.0 - 50A 160090 - 100A 160100 - 200A 160110 - 400A 160120 - 600A 160130 - 1000A 160140 - 1250A 160150 - 1500A 160160 - 2000A 16019

Voltmeter VLT Size Part No.Scale 0 - 500V 72 x 72 16005Ammeter AMPScale x/5 via CT 72 x 72 16004

Single phase Modules Part No.CE 25/90A 6 15464CEr 25/90a with pulse 6 15466Three phaseCE 50 - 400A 6 15465CEr 50 - 400A with pulse 6 15467

Digitalmultimeter

PMCEI EN 61010

Currenttransformers

TACEI EN 61010

Modular multimeters Modules Part No.PM9 4 15196Panel mounting SizePM500 10 - 440V ac 92 x 92 50980PM500 24 - 48V dc 92 x 92 50981PM500 modbus connection 50982PM500 pulse output module 50983PM500 I/O module 50984

IP Size ø Size ■■ Part No.40/5A 21 20 x 5 1650050/5A 21 20 x 5 1650175/5A 21 20 x 5 16502100/5A 21 20 x 5 16503125/5A 21 20 x 5 16504150/5A 21 20 x 5 16505200/5A 21 20 x 5 16506250/5A 22 30 x 10 16511300/5A 35 40 x 10 16519400/5A 65 x 32 16529500/5A 65 x 32 16530

IP Size ■■ Part No.600/5A 65 x 32 16531800/5A 65 x 32 165321000/5A 65 x 32 165331250/5A 65 x 32 165341250/5A 127 x 38 165401500/5A 84 x 38 165381500/5A 127 x 38 165412000/5A 127 x 38 165422500/5A 127 x 38 165433000/5A 127 x 38 165444000/5A 127 x 38 16547

Selector switches

CMCEI EN 61010

Counters

CI, CH

Ammeter selector Modules Part No.CMA 4 pos. (O-L1-L2-L3) 3 15126Voltmeter selectorCMV 7 pos. (L3/1-0-L3N) 3 15125

Ammeter selector SIZE Part No.CMA 4 pos. (O-L1-L2-L3) 48 x 48 16017Voltmeter selectorCMV 7 pos. (L3/1-0-L3N) 48 x 48 16018

Impulse counter Modules Part No.CI Vn 230-240V ac 2 15443Hours counterCH Vn 230-240V ac 2 15440

Nationwide supporcall the Customer Informati

control

Control relays

RLI, RBN, RTBT, ERLIEC 255

Auxiliary contactsfor RLI

ACT

Auxiliaries Modules Part No.Contactor auxiliary ACTo+f 0.5 15914AuxiliariesTime control ACTt 24/240 V 1 15917Central control ACTc 230/240 V 1 18308Central control ACTc 24/48 V 1 18309Suppressor ACTp 230/240 V 1 15920Suppressor ACTp 24 V 1 15919AccessoriesSet of 10 clips 15415

P 2P 3P 4P30/240 230/240 24 230/240 230/240 24NO 1NO+1Nc 2NO 2Nc 2NO 3NO 2NO+2Nc 4NO 4Nc 4NO 4Nc

1 1 1 2 1 1 2 2 3 2 3 2 3 6 2 3 2 3 2 3

15956 159575958 15959 15960 16020 15961 15964 15962 15963 16022 16023

15966 15967 15968 1596915971 16024 15972 15975 15973 15974 16025 16026

15978manual override CT

15981 15982 1598315984 15986

15987 15988

Pole 1P 2PVn (Vca) 230/240 12/24 230/240 48 24 12Contact 1NO/Nc 1NO/Nc 1NO+1NO/Nc 1NO+1NO/Nc 1NO+1NO/Nc 1NO+1NO/NcModules 1 1 1 1 1 1Changeover relay RLIIn (A) 10 15535 15536 15537 15538Extension for RLI ERLIn (A) 10 15539 15540 15541 15542Interface relay LV RBNIn (A) 2 15393Interface relay ELV RTBTIn (A) 2 15416

Switches

CMCEI EN 60669-1

Pushbuttons

BPCEI EN 60669-1

Indicators

VCEI EN 60947-5-1

Control transformers

TREN 60742

Accessories for TR

Sounders

SO, RO

Supportdevices

Selector 1-2 Modules Part No. Single Modules Part No.1P 2 pos. 1 18070 1NO 1 180322P 2 pos. 2 18071 1Nc 1 180301NO+1Nc 2 pos. 1 18072 1NO+1Nc 1 18033Selector 1-0-2 Double1P 3 pos. 1 18073 1NO+1Nc green and red 1 180342P 3 pos. 2 18074 1NO+1Nc green and green 1 18035

Single + indicator1NO green 230 V 1 180361NO green 12÷48 V 1 180381NO red 230 V 1 180371NO red 12÷48 V 1 18039

Vn (V) 230V 12÷48 V Bell transformers Modules Part No. Safety shields Part No. Bell Modules Part No. Support for XB4, XB5 Modules Part No.Single Modules 4 VA 8/12 V 2 15213 For TR 15212, 15213, 15216 15228 8÷12 V - 80dB 1 15321 Support 3 15151Red 1 18320 18330 8 VA 8/12 V 2 15216 For TR 15218, 15219, 15220 15230 230 V - 80dB 1 15320 for Ø 22.5 mm devicesRed (flashing) 1 18326 16 VA 8/12 V 2 15212 15222 Buzzer Universal supportGreen 1 18321 18331 25 VA 12/24 V 3 15215 8÷12 V - 70dB 1 15323 Blank support 3 15152White 1 18322 18332 Safety transformers 230 V - 70dB 1 15322Blue 1 18323 18333 16 VA 12/24 V 5 15218Yellow 1 18324 18334 25 VA 12/24 V 5 15219Double 40 VA 12/24 V 5 15220Green and red 1 18325 63 VA 12/24 V 5 15222Triple3 yellow 1 18327

AccessoriesSTI/SBI

Protectionrelay

RCMonoblockPRD: IEC 61643-1

Surge protection

PF:NF C 61740 (1995)

Accessories Part No.Indicator 230 Vca 15668Busbar1 row 1P 12 modules 148811 row 1P+N 12 modules 148801 row 2P 12 modules 148821 row 3P 12 modules 14883Accessories4 connectors 25mm2 1488540 insulators 1488840 insulators 1P, 2P 1488640 insulators 3P, 2P 14887

2P 3P 3P+N

15650 15655 1565715651 15656 156582 3 3

Pole Modules 1P+N 1P+N 3P+N 3P+NPF monoblockImax (kA) In (kA)65 20 15684 1568530 10 15689 15687 15690 1568815 2 15692 156938 2 15695 15696PRD withdrawable cartridgeImax (kA) In (kA)65 20 16557 1655940 15 16562 16567 16564 1656915 5 16572 165748 2 16577 16579

Multifunctionaltimers

ITM

Protection relays Modules Part No.Under current relay 2 21181Undervoltage relay 2 21182Phase failure relay 2 21180

Part No.16065

16067

16066

16068

16070

16069

Multifunctional time switch Modules Part No.ITM 6 input 4 output controller 20 15270AccessoriesMemory cartridge 15280

Lightingcontrol

TV dimmers Motion and presencedetection

Energy management

THTHP programmable thermostat

Accessories for TH, THP thermostat

Electronic Modules Part No.TH3 1 channel reg. +8°C÷+26°C 4 15841TH6 1 channel reg. -30°C÷+90°C 4 15840

Probes for TH Part No.Ground probe 15845Ambient probe 15846Outdoor probe 15847Collar probe 15848

Light sensitiveswitch

ICIEC 669-1/5EN 61000-3-2

Pre-definedtimers

rt on one number - ion Centre on: 0870 608 8 608

The first Europeanelectrical installation

portal

member of

.co.uk

Motion detectors Part No.CDM motion detector 16990CE motion detector 57655Presence detectorsCDP 360 degree detector 16992CDPt remote control detector 16994

TV dimmers Modules Part No.TVe700 remote dimmer 2 15285TV700 remote dimmer 2 15287TV0 remote dimmer 4 15289TVBo remote dimmer 2 15297AuxiliariesRgo light regulator 1 15291Iso switch with optical control 1 15296NTVo preset control 1 15300TTVo progressive control 1 15301Rpo optical repeater 1 15293PTV1 halogen pre-charge 15417

Regulation 2 to 200 lux Modules Part No.IC200 1 channel 2.5 15284Regulation 2 to 2000 luxIC2000 1 channel 3.5 15368Regulation 2 to 2000 lux programmableIC2000P 1 channel + hourly 24H+7 day 5 15286AccessoriesPhotocell IP65 for IC200 15281Photocell IP54 for IC2000/2000P 15268

Electro-mechanical Modules Part No.MIN 1 - 7 minutes 1 15363Timed delayPRE delay 30 seconds - 8 minutes 1 15233for 20 minutes10 - 100 seconds