proposed structure - wood county, ohio 2019... · 2019-07-17 · 660 6 6 5 665 670 67 0 6 7 0 670 d...
TRANSCRIPT
660
665
665
670
670
670
670
DA
TE
ST
RU
CT
UR
E FIL
E
NU
MB
ER
CH
EC
KE
DR
EVIS
ED
DESIG
NE
DD
RA
WN
RE
VIE
WE
D
SIT
E P
LA
N
Np
w:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
P001.d
gn 5/29/2019 12:4
8:4
1
PM jmiller
ST
A. 36+25.49
ST
A. 36+67.49
WO
O-
TR
79
B-0.4
0
LENGTHPILE TYPE
55'
55'
REAR ABUTMENT
FORWARD ABUTMENT
TYPE:
SPAN: 23'-11"(`) FACE-TO-FACE OF ABUTMENTS
ROADWAY: 24'-11"(`) FACE-TO-FACE OF RAILING,
ESTIMATED PAY LENGTHS
LOCATION
PLAN
EXISTING STRUCTURE
PROPOSED STRUCTURE
ALIGNMENT: TANGENT
APPROACH SLABS: NONE
STRUCTURE FILE NUMBER: 8745730
CROWN: 0.0156(`) FT/FT
WEARING SURFACE: ASPHALT CONCRETE
ROADWAY:
COORDINATES: LATITUDE
FUTURE WEARING SURFACE = 60 PSF
ALIGNMENT: TANGENT
APPROACH SLABS: NONE
TYPE:
PROPOSED WORK:
SPAN:
CROWN: 0.0156 FT/FT
SKEW: NONE
REMOVE EXISTING SUPERSTRUCTURE,
PRESTRESSED CONCRETE BOX BEAMS WITH REINFORCED
LONGITUDE
39'-0" c/c BEARINGS
LOADING: HL-93
CONCRETE DECK AND SUBSTRUCTURE
PRESERVE LOWER PORTION OF EXISTING ABUTMENTS
AND WINGWALLS, AND CONSTRUCT NEW STRUCTURE
WEARING SURFACE: 1" MONOLITHIC CONCRETE
36+50 37+00
680
670
660
650
640
680
670
660
650
640
670.07
670.24
670.35
670.53
670.18
669.90
669.73
8745731
JA
MJ
AM
PA
T
MJL
05/29/19
WO
OD C
OU
NT
Y
BRID
GE
NO.
WO
O-
TR79
B-0040
1 S
EA
GA
TE, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
2
12
11
N 41°24'04.70"
W 83°46'36.59"
28'-0" FACE-TO-FACE OF RAILING
L
ON
G J
UD
SO
N R
OA
D
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
26'-7"(`) OUT-TO-OUT OF DECK
LOADING: UNKNOWN
SKEW: 5°00'00"(`) LEFT FORWARD
DATE BUILT: 1951
REINFORCED CONCRETE SLAB AND REINFORCED CONCRETE
SUBSTRUCTURE
HP10x42
HP10x42
1
BENCHMARK DATA
BENCHMARK #1:
BENCHMARK #2:
TRAFFIC DATA
CURRENT ADT (2019) = DESIGN ADT (2039) =
DESIGN ADTT (2039) =CURRENT ADTT (2019) =
DIRECTIONAL DISTRIBUTION = 0.55
120 131
= 668.87
HYDRAULIC DATA
10 10
PROPOSED STRUCTURE CLEARS 10-YEAR FLOW BY 0.56'
V100
= 667.10
V10
Q10
EXIST. STRUCTURE: PROP. STRUCTURE:
= 3.22 FPS
= 667.06
= 3.99 FPS
= 668.81
Q100
100HW
10HW
V100
V10
100HW
10HW
= 470 CFS = 715 CFS
= 2.89 FPS
= 3.93 FPS
PROPOSED STRUCTURE IS SUBMERGED BY 100-YEAR FLOW BY 0.64'
DRAINAGE AREA = 6.40 SQ. MI.
EXIST. LOW CHORD EL. 668.71(`)
PROP. LOW CHORD EL. 668.23 (AT FORWARD ABUTMENT)
36+00
54.00' 54.00'BRIDGE LIMITS = 42.00'
ST
A. 35+71.
49
ME
ET E
XIS
T.
ST
A. 37+21.
49
ME
ET E
XIS
T.
EL. 670.04
EL. 670.50
EL. 670.42
EL. 669.74
ST
A. 36+25.49
ST
A. 36+67.49
HP10x42 PILES (TYP.)NORMAL WATER EL. 659.50(`)
ORDINARY HIGH WATER EL. 660.02(`)
EL. 662.77 EL. 662.69
HW EL. 668.87
HW EL. 667.1010
100
PROP. PROFILE GRADE
TO BE REMOVED
SUPERSTRUCTURE
EXIST.
FIX EXP.
(TYP.)
ABUTMENT TO REMAIN
PORTIONS OF EXIST.
GEOTEXTILE FABRIC, 2'-0" THICK (TYP.)
ROCK CHANNEL PROTECTION, TYPE C WITH
14'-
0"
14'-
0"
F/
F R
AILIN
G
28'-
0"
SAW CUTSAW CUT
B-001-0-18
B-002-0-18
39'-0" c/c BRG.
STA. 35+71.49
STA. 37+21.49
S 89°26'58" E
STA. 36+65.99
| BRG. FWD. ABUT.
STA. 36+26.99
| BRG. REAR ABUT.
STA. 36+22.74 (TYP.)
FIRST POST OFF BRIDGE
STA. 36+70.24 (TYP.)
FIRST POST OFF BRIDGE
LEGEND
SOIL BORING LOCATION
GEOTEXTILE FABRIC, 2'-0" THICK (TYP.)
ROCK CHANNEL PROTECTION, TYPE C WITH
TO BE RELOCATED
TELECOM LINE
EXIST. OVERHEAD
ASSEMBLY, TYPE 1 (TYP.)
MGS BRIDGE TERMINAL
CR
EE
K
TO
NT
OG
AN
Y
WES
T B
RA
NC
H
4'-
0ƒ
"(̀)
7'-
5•
"(̀)
6'-
3ƒ
"(̀)
5'-
10•
"(̀) BENCHMARK #3:
2.
1.
NOTES
ALL ELEVATIONS ARE BASED ON NAVD88 DATUM.
ARE TO REMAIN UNLESS NOTED OTHERWISE.
ALL EXISTING OVERHEAD AND UNDERGROUND UTILITIES
S 89°48'31" E
5' RAD. (TYP.)
DECK AREA: 1,176 SF
*ABOVE EL. 665.42 (TYP.)
REMOVE EXIST. ABUTMENT* =
+10.49
+82.49
MGS TYPE T (TYP.)
ANCHOR ASSEMBLY,
PROFILE ALONG | CONSTRUCTION LONG JUDSON ROAD
JUDSON ROAD
| CONST. LONG
REMAIN IN PLACE
ELECTRIC LINE TO
EXIST. OVERHEAD
STA. 10+00.00, 0' OFFSET, EL. 672.39
MAG NAIL ON ROADWAY
NW ‚ SEC 13
STA. 36+76.51, 0' OFFSET, EL. 669.96
IRON PIN IN PIPE ON ROADWAY
NORTH ‚ POST SEC 13
STA. 63+52.80, 0' OFFSET, EL. 671.14
RAILROAD SPIKE ON ROADWAY
NE ‚ SEC 13
PER STD. DWG. RM-1.1
INSTALL MONUMENT TYPE C
WASHINGTON TWP.,
NORTH ‚ POST SEC 13
LIMITS (TYP.)
CONSTRUCTION
60.00' V.C.
P.V.I. STA. 36+46.49, EL. 670.70
+0.87% -1.28%+0.13%(`)
GRADE
PROFILE
EXIST.
-0.40%(`)
36 37
PI Sta. 36+76.51
670.50
670.53
670.34
670.29
670.02
670.08
GR
AD
E E
LE
VA
TIO
NS
PR
OP
OS
ED P
RO
FIL
E
GR
AD
E E
LE
VA
TIO
NS
EXIS
TIN
G P
RO
FIL
E
3
2
GE
NE
RA
L
NO
TES - 1
EXISTING STRUCTURE VERIFICATION:
MONOLITHIC WEARING SURFACE:
DECK PROTECTION METHOD:
DESIGN DATA:
DESIGN LOADING:
OPERATIONAL IMPORTANCE:
DESIGN SPECIFICATIONS:
AND TO THE FOLLOWING SUPPLEMENTAL SPECIFICATION:
REFER TO THE FOLLOWING STANDARD BRIDGE DRAWINGS:
IN-STREAM WORK:
DEMOLITION DEBRIS:
UTILITIES:
WORK LIMITS:
RIGHT-OF-WAY:
DIMENSIONS THAT HAVE BEEN VERIFIED IN THE FIELD.
THE OWNER WILL PAY FOR ALL PROJECT WORK BASED UPON ACTUAL DETAILS AND
ABOVE AND UPON A PREBID EXAMINATION OF THE EXISTING STRUCTURE. HOWEVER,
BASE CONTRACT BID PRICES UPON A RECOGNITION OF THE UNCERTAINTIES DESCRIBED
102.05 AND 105.02.
TENTATIVE AND APPROXIMATE. THE CONTRACTOR IS REFERRED TO CMS SECTIONS
THE EXISTING STRUCTURE AND THE PROPOSED WORK, BUT THEY SHALL BE CONSIDERED
FIELD OBSERVATIONS AND MEASUREMENTS. CONSEQUENTLY, THEY ARE INDICATIVE OF
STRUCTURE HAVE BEEN OBTAINED FROM PLANS OF THE EXISTING STRUCTURE AND FROM
DETAILS AND DIMENSIONS SHOWN ON THESE PLANS PERTAINING TO THE EXISTING
EXISTING STRUCTURE VERIFICATION:
MONOLITHIC WEARING SURFACE IS ASSUMED, FOR DESIGN PURPOSES, TO BE 1" THICK.
MONOLITHIC WEARING SURFACE:
STEEL DRIP STRIP
2•" CONCRETE COVER
EPOXY COATED REINFORCING STEEL
DECK PROTECTION METHOD:
INITIAL STRESS = 202.5 KSI (LOW RELAXATION STRANDS)
ULTIMATE STRENGTH = 270 KSI
AREA = 0.153 SQ. IN. PER STRAND
PRESTRESSING STRAND:
COMPRESSIVE STRENGTH (RELEASE) = 5.0 KSI
COMPRESSIVE STRENGTH (FINAL) = 7.0 KSI
CONCRETE FOR PRESTRESSED BEAMS:
STEEL H-PILES - ASTM A572 - YIELD STRENGTH 50 KSI
REINFORCING STEEL - ASTM A615 OR A996, GRADE 60, MIN. YIELD STRENGTH 60 KSI
CONCRETE CLASS QC1 - COMPRESSIVE STRENGTH 4.0 KSI (SUBSTRUCTURE)
CONCRETE CLASS QC2 - COMPRESSIVE STRENGTH 4.5 KSI (SUPERSTRUCTURE)
DESIGN DATA:
FUTURE WEARING SURFACE (FWS) OF 0.060 KIPS PER SQUARE FOOT
HL-93
DESIGN LOADING:
1.3.5 AND THE ODOT BRIDGE DESIGN MANUAL, 2007.
IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, ARTICLE
A LOAD MODIFIER OF 1.00 HAS BEEN ASSUMED FOR THE DESIGN OF THIS STRUCTURE
OPERATIONAL IMPORTANCE:
8TH EDITION, AND THE ODOT BRIDGE DESIGN MANUAL, 2007.
BY THE AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS,
THIS STRUCTURE CONFORMS TO THE "LRFD BRIDGE DESIGN SPECIFICATIONS" ADOPTED
DESIGN SPECIFICATIONS:
4/19/19 DATED800
AND TO THE FOLLOWING SUPPLEMENTAL SPECIFICATION:
7/20/18REVISEDTST-1-99
7/20/18REVISED PSBD-2-07
7/18/03REVISEDDS-1-92
REFER TO THE FOLLOWING STANDARD BRIDGE DRAWINGS:
PILE SPLICES:
PILES TO BEDROCK:
PLAN:
ITEM 202 - PORTIONS OF STRUCTURE REMOVED, OVER 20 FOOT SPAN, AS PER
ITEM 201 - CLEARING AND GRUBBING:
CONSTRUCTION NOISE:
BEFORE THE WELDING IS PERFORMED.
MANUFACTURER'S WRITTEN ASSEMBLY PROCEDURE SUPPLIED TO THE ENGINEER
INSTALL AND WELD THE SPLICER TO THE PILE SECTIONS IN ACCORDANCE WITH THE
PARSIPPANY, NEW JERSEY 07054
8 WOOD HOLLOW RD. PLAZA 1
ASSOCIATED PILE AND FITTING CORPORATION
SPLICER. FURNISH SPLICERS FROM THE FOLLOWING MANUFACTURER:
TO SPLICE STEEL H-PILES, THE CONTRACTOR MAY USE A MANUFACTURED H-PILE
IN LIEU OF USING THE FULL PENETRATION BUTT WELDS SPECIFIED IN CMS 507.09
PILE SPLICES:
HP10x42 PILES 60 FEET LONG, ORDER LENGTH
ABUTMENT PILES:
THE TOTAL FACTORED LOAD IS 146.9 KIPS PER PILE FOR THE ABUTMENT PILES.
THE REQUIRED DEPTH TO BEDROCK AND REFUSAL.
LEAST 20 BLOWS FROM THE PILE HAMMER. SELECT THE HAMMER SIZE TO ACHIEVE
OBTAINED WHEN THE PILE PENETRATION IS AN INCH OR LESS AFTER RECEIVING AT
DRIVE PILES TO REFUSAL ON BEDROCK. THE OWNER WILL CONSIDER REFUSAL TO BE
PILES TO BEDROCK:
SUBMIT CONSTRUCTION PLANS ACCORDING TO CMS 501.05.
THE USE OF EXPLOSIVES AND/OR HEADACHE BALLS WILL NOT BE PERMITTED.
TO A NEAT AND LEVEL SURFACE WITH NO PROTRUDING REINFORCING BARS.
THE LIMITS OF PROPOSED REMOVALS AND REMOVE EXISTING ABUTMENT WALLS
THE EXISTING ABUTMENT WALLS AND WINGWALLS ABOVE EL. 665.42. SAW CUT
PORTIONS OF THE EXISTING ABUTMENTS AS DETAILED IN THE PLANS. REMOVE 2.
SLAB, ASPHALT WEARING SURFACE, AND RAILING.
THE EXISTING SUPERSTRUCTURE IN ITS ENTIRETY, INCLUDING THE CONCRETE 1.
INCLUDE BUT NOT NECESSARILY BE LIMITED TO THE FOLLOWING:
DETAILED IN THE PLANS AND AS DIRECTED BY THE ENGINEER. THE REMOVALS SHALL
THIS ITEM SHALL INCLUDE THE REMOVAL OF EXISTING STRUCTURE COMPONENTS AS
PLAN:
ITEM 202 - PORTIONS OF STRUCTURE REMOVED, OVER 20 FOOT SPAN, AS PER
SUM PRICE BID FOR ITEM 201, CLEARING AND GRUBBING.
SET FORTH IN THE SPECIFICATIONS UNDER THIS ITEM ARE INCLUDED IN THE LUMP
GENERAL SUMMARY FOR ITEM 201, CLEARING AND GRUBBING. ALL PROVISIONS AS
WITHIN THE LIMITS OF THE PROJECT, A LUMP SUM QUANTITY IS INCLUDED IN THE
ALTHOUGH THERE ARE NO TREES OR STUMPS SPECIFICALLY MARKED FOR REMOVAL
ITEM 201 - CLEARING AND GRUBBING:
REASONABLE AND EFFICIENT PERFORMANCE OF SUCH EQUIPMENT.
EXCEEDS THE NOISE CUSTOMARILY AND NECESSARILY ATTENDANT TO THE
ANY TIME ANY DEVICE IN SUCH A MANNER THAT THE NOISE CREATED SUBSTANTIALLY
BETWEEN THE HOURS OF 9:00 PM AND 7:00 AM. IN ADDITION, DO NOT OPERATE AT
IMPACTS, DO NOT OPERATE POWER-OPERATED CONSTRUCTION-TYPE DEVICES
CONSTRUCTION NOISE. IN ORDER TO MINIMIZE ANY ADVERSE CONSTRUCTION NOISE
ACTIVITIES AND LAND USE ADJACENT TO THIS PROJECT MAY BE AFFECTED BY
CONSTRUCTION NOISE:
WORK SHALL BE STAGED FROM THE AREAS BEHIND THE EXISTING ABUTMENTS.
DISTURBANCE TO THE EXISTING STREAM. TO THE MAXIMUM EXTENT PRACTICABLE,
STRICTLY PROHIBITED. IT IS THE INTENT OF THIS PROJECT TO AVOID
CONSTRUCTION IN THE STREAM OF COFFERDAMS, ACCESS PADS, OR FORDS IS
THE CROSSING OF THE STREAM WITH VEHICLES OR CONSTRUCTION EQUIPMENT AND THE
IN-STREAM WORK:
STREAM SHALL BE REMOVED AS SOON AS POSSIBLE.
DEBRIS FROM ENTERING THE STREAM. ANY MATERIAL THAT DOES FALL INTO THE
THE CONTRACTOR SHALL TAKE PRECAUTIONS TO AVOID AND/OR LIMIT DEMOLITION
DEMOLITION DEBRIS:
1-800-362-2764.
CALL OHIO811 TWO (2) WORKING DAYS BEFORE YOU DIG, TOLL FREE NO.
E-MAIL: [email protected]
PHONE: 330-253-8267
CONTACT: AL GUEST
AKRON, OH 44303
120 RAVINE STREET
VERIZON
E-MAIL: [email protected]
PHONE: 419-249-5218
CONTACT: RANDY SWOPE, P.E.
HOLLAND, OH 43528
6099 ANGOLA ROAD
TOLEDO EDISON
CONSTRUCTION LIMITS, TOGETHER WITH THEIR RESPECTIVE OWNERS:
LISTED BELOW ARE ALL UTILITIES LOCATED WITHIN OR ADJACENT TO THE PROJECT
UTILITIES:
INSIDE OR OUTSIDE THESE WORK LIMITS.
AND WORK ZONE TRAFFIC CONTROL DEVICES REQUIRED BY THESE PLANS WHETHER
PROVIDE THE INSTALLATION AND OPERATION OF ALL WORK ZONE TRAFFIC CONTROL
THE WORK LIMITS SHOWN ON THESE PLANS ARE FOR PHYSICAL CONSTRUCTION ONLY.
WORK LIMITS:
THESE PLANS.
ALL WORK IS TO BE PERFORMED WITHIN THE EXISTING RIGHT-OF-WAY SHOWN IN
RIGHT-OF-WAY:
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
N001.d
gn 5/29/2019 12:4
8:4
3
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
4
3
GE
NE
RA
L
NO
TES - 2
PLAN ABBREVIATIONS:
OHIO EPA NOTIFICATION OF DEMOLITION FOR ASBESTOS:
SEEDING AND MULCHING:
OBJECT MARKER SIGNS:
LOCATION OF GUARDRAIL:
DECK PLACEMENT DESIGN ASSUMPTIONS:
ITEM 614 - MAINTAINING TRAFFIC (ROAD CLOSED):
PORTIONS OF STRUCTURE REMOVED, OVER 20 FOOT SPAN, AS PER PLAN.
FOR THIS WORK SHALL BE INCLUDED IN THE LUMP SUM PRICE BID FOR ITEM 202 -
TO COMPLETE, SUBMIT, AND COMPLY WITH THE OEPA NOTIFICATION FORM. PAYMENT
THE CONTRACTOR SHALL FURNISH ALL LABOR, EQUIPMENT AND MATERIALS NECESSARY
AND/OR RENOVATION.
WORKING DAYS (14 CALENDAR DAYS TOTAL) PRIOR TO THE START OF ANY DEMOLITION
ADDRESS ON THE FORM OR ONLINE AT ebiz.epa.ohio.gov AT LEAST TEN (10)
(OEPA) NOTIFICATION OF DEMOLITION AND RENOVATION FORM AND SUBMIT IT TO THE
THE CONTRACTOR SHALL COMPLETE THE OHIO ENVIRONMENTAL PROTECTION AGENCY
REPORT CAN BE REVIEWED AT THE WOOD COUNTY ENGINEER'S OFFICE.
COPY OF THE ASBESTOS INSPECTION REPORT IS ON FILE AND THE FINDINGS OF THIS
EVALUATION SPECIALIST. NO ASBESTOS CONTAINING MATERIAL WAS IDENTIFIED. A
TONTOGANY CREEK WAS COMPLETED IN JULY 2018 BY A CERTIFIED ASBESTOS HAZARD
AN ASBESTOS SURVEY OF THE EXSTING WOO-T079B-0040 BRIDGE OVER WEST BRANCH
OHIO EPA NOTIFICATION OF DEMOLITION FOR ASBESTOS:
CALCULATIONS FOR SEEDING AND MULCHING ARE BASED ON THESE LIMITS.
EMBANKMENTS WITHIN THE PROPOSED CONSTRUCTION LIMITS. QUANTITY
SEEDING AND MULCHING SHALL BE APPLIED TO ALL AREAS OF EXPOSED SOIL ON NEW
0.5 MGALITEM 659 - WATER
0.02 ACREITEM 659 - LIME
0.01 TONITEM 659 - COMMERCIAL FERTILIZER
4 SYITEM 659 - REPAIR SEEDING AND MULCHING
89 SYITEM 659 - SEEDING AND MULCHING
10 CYITEM 659 - TOPSOIL
PERMANENT SEEDED AREAS:
THE FOLLOWING QUANTITIES ARE PROVIDED TO PROMOTE GROWTH AND CARE OF
SEEDING AND MULCHING:
12 SFITEM 630 - SIGN, FLAT SHEET
36 FTITEM 630 - GROUND MOUNTED SUPPORT, NO. 3 POST
THE FOLLOWING QUANTITIES HAVE BEEN INCLUDED IN THE ESTIMATED QUANTITIES:
STANDARD CONSTRUCTION DRAWING TC-41.20. EACH POST WILL BE 9' IN LENGTH.
THE SIGNS WILL BE MOUNTED ON NEW NO. 3 POSTS AND WILL BE INSTALLED AS PER
TWO SIGNS PER APPROACH WILL BE INSTALLED.
SHOULDERS, FACING THE APPROACHES, AND BEHIND THE GUARDRAIL. A QUANTITY OF
OBJECT MARKER SIGNS (OM3) WILL BE PLACED ON EACH APPROACH OFF BOTH
OBJECT MARKER SIGNS:
ALL INSTALLATIONS WILL AFFORD MAXIMUM PROTECTION FOR TRAFFIC.
ADJUSTMENT PRIOR TO FINAL ACCEPTANCE. THE ENGINEER SHALL BE SATISFIED THAT
THE LOCATIONS OF GUARDRAIL RUNS, AS SHOWN ON THESE PLANS, ARE SUBJECT TO
LOCATION OF GUARDRAIL:
THE SAFETY HANDRAIL OF 65".
A MAXIMUM DISTANCE FROM THE CENTERLINE OF THE FASCIA GIRDER TO THE FACE OF
A MAXIMUM SPACING OF OVERHANG FALSEWORK BRACKETS OF 48".
A MINIMUM OUT-TO-OUT WHEEL SPACING AT EACH END OF THE MACHINE OF 103".
AN EIGHT WHEEL FINISHING MACHINE WITH A MAXIMUM WHEEL LOAD OF 2.2 KIPS.
DEVIATION FROM THESE DESIGN ASSUMPTIONS.
PARAMETERS AND WILL ASSUME RESPONSIBILITY FOR SUPERSTRUCTURE ANALYSIS FOR
RESPONSIBLE FOR THE DESIGN OF THE FALSEWORK SUPPORT SYSTEM WITHIN THESE
THE ANALYSIS AND DESIGN OF THE SUPERSTRUCTURE. THE CONTRACTOR IS
THE FOLLOWING ASSUMPTIONS OF CONSTRUCTION MEANS AND METHODS WERE MADE FOR
DECK PLACEMENT DESIGN ASSUMPTIONS:
OF UNIFORM TRAFFIC CONTROL DEVICES (OMUTCD).
614, OTHER APPLICABLE PORTIONS OF THE SPECIFICATIONS, AND THE OHIO MANUAL
ALL WORK AND TRAFFIC CONTROL DEVICES SHALL BE IN ACCORDANCE WITH ODOT CMS
ODOT CMS 108.07.
TWENTY (120) CALENDAR DAYS. LIQUIDATED DAMAGES WILL BE ASSESSED AS PER
EFFECT. THE DURATION OF THE ROAD CLOSURE IS NOT TO EXCEED ONE HUNDRED
FOURTEEN (14) CALENDAR DAYS IN ADVANCE OF WHEN THE DETOUR ROUTE WILL BE IN
THE CONTRACTOR SHALL ADVISE THE WOOD COUNTY ENGINEER'S OFFICE A MINIMUM OF
BOTH ENDS OF THE PROJECT PER ODOT STANDARD DRAWING MT-101.60.
CONTRACTOR SHALL ALSO PLACE AND MAINTAIN THE THREE SIGNS LEADING IN TO
PROJECT DURING THE PERIOD IN WHICH THE ROAD IS CLOSED TO TRAFFIC. THE
LIGHTS AS DETAILED IN ODOT STANDARD DRAWING MT-101.60 AT BOTH ENDS OF THE
SIGNS AT THE NEAREST INTERSECTIONS, SIGN SUPPORTS, BARRICADES, GATES AND
THE CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN STANDARD "ROAD CLOSED"
ADVANCE WARNING SIGNAGE THROUGHOUT THE DURATION OF THE PROJECT.
SHALL ADEQUATELY SIGN THE DETOUR ROUTE AND MAINTAIN ALL DETOUR SIGNAGE AND
235) TO KELLOGG ROAD TO RANGELINE ROAD. THE WOOD COUNTY ENGINEER'S OFFICE
THE ROAD CLOSURE WILL HAVE A DESIGNATED DETOUR ROUTE OF OTSEGO PIKE (S.R.
ITEM 614 - MAINTAINING TRAFFIC (ROAD CLOSED):
= TYPICAL
= TOWNSHIP ROAD
= STANDARD DRAWING
= STATION
= SPACE, SPACED, SPACES
= REAR ABUTMENT
= PROPOSED
= PREFORMED EXPANSION JOINT FILLER
= NEAR FACE
= MINIMUM
= MAXIMUM
= INCREMENT
= FORWARD
= FAR FACE
= FORWARD ABUTMENT
= FACE-TO-FACE
= EXISTING
= EQUAL
= ELEVATION
= EACH FACE
= DIAMETER
= CONSTRUCTION JOINT
= CONSTRUCTION
= CONCRETE
= CLEAR COVER
= CAST-IN-PLACE
= CENTER-TO-CENTER
= CENTERLINE
= BRIDGE TERMINAL ASSEMBLY
= BEARING
= AVERAGE DAILY TRUCK TRAFFIC
= AVERAGE DAILY TRAFFIC
= ABUTMENT
TYP.
T.R.
STD. DWG.
STA.
SPA.
R.A.
PROP.
PEJF
N.F.
MIN.
MAX.
INC.
FWD.
F.F.
F.A.
F/F
EXIST.
EQ.
EL.
E.F.
DIA.
C.J.
CONST.
CONC.
CLR.
C.I.P.
c/c
|
B.T.A.
BRG.
ADTT
ADT
ABUT.
PLAN ABBREVIATIONS:
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
N002.d
gn 5/29/2019 12:4
8:4
5
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
ITEM TOTAL UNIT DESCRIPTION GENERALEXTENSION
ITEM
ABUTMENT
REAR
ABUTMENT
FORWARD
STRUCTURE
SUPER-
CHKD. BY:
CALC. BY:ESTIMATED QUANTITIES
03/29/2019
03/29/2019
DATE:
DATE:
PAT
JAM
5
4
ES
TI
MA
TE
D
QU
AN
TITIES - 1
SHEET NO.
REFERENCE
3
2
ESTIMATED QUANTITIES CONTINUE ON SHEET 5 OF 11
TRAFFIC CONTROL
PAVEMENT
EROSION CONTROL
ROADWAY
630
630
630
630
441
441
407
304
832
659
659
659
659
659
659
626
623
606
606
606
204
203
202
201
86002
84900
80100
03100
50200
50000
10000
20000
30000
35000
31000
20000
14000
10000
00300
00112
38500
35002
26550
20000
10000
10000
23000
11000
6
6
12
36
19
11
15
91
5,000
0.5
0.02
0.01
4
89
10
12
1
4
4
4
274
53
143
LS
6
6
12
36
19
11
15
91
5,000
0.5
0.02
0.01
4
89
10
12
1
4
4
4
274
53
143
LS
EACH
EACH
SF
FT
CY
CY
GAL
CY
EACH
MGAL
ACRE
TON
SY
SY
CY
EACH
EACH
EACH
EACH
EACH
SY
CY
SY
REMOVAL OF GROUND MOUNTED POST SUPPORT AND DISPOSAL
REMOVAL OF GROUND MOUNTED SIGN AND DISPOSAL
SIGN, FLAT SHEET
GROUND MOUNTED SUPPORT, NO. 3 POST
ASPHALT CONCRETE INTERMEDIATE COURSE, TYPE 1, (448)
ASPHALT CONCRETE SURFACE COURSE, TYPE 1, (448), PG64-22
TACK COAT
AGGREGATE BASE
EROSION CONTROL
WATER
LIME
COMMERCIAL FERTILIZER
REPAIR SEEDING AND MULCHING
SEEDING AND MULCHING
TOPSOIL
BARRIER REFLECTOR, TYPE 3 (BIDIRECTIONAL)
MONUMENT ASSEMBLY
MGS BRIDGE TERMINAL ASSEMBLY, TYPE 1
ANCHOR ASSEMBLY, MGS TYPE T
FLARED END SECTION
SUBGRADE COMPACTION
EXCAVATION
PAVEMENT REMOVED
CLEARING AND GRUBBING
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
Q001.d
gn 5/29/2019 12:4
8:4
7
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
ITEM TOTAL UNIT DESCRIPTION GENERALEXTENSION
ITEM
ABUTMENT
REAR
ABUTMENT
FORWARD
STRUCTURE
SUPER-
CHKD. BY:
CALC. BY:ESTIMATED QUANTITIES
03/29/2019
03/29/2019
DATE:
DATE:
PAT
JAM
6
5
SHEET NO.
REFERENCE
ES
TI
MA
TE
D
QU
AN
TITIES - 2
INCIDENTALS
STRUCTURES
24
18
16
23
1,925
5
275
300
74
24
18
16
23
1,925
5
275
300
74
94
90
28
14
23
16
7
19
26
4,565
624
623
614
613
601
SPECIAL
517
516
516
516
516
515
512
511
511
509
507
507
507
505
503
503
202
10000
10000
11000
41200
32204
51822300
70000
41500
41100
14020
13600
12030
10100
43510
31610
10000
93300
00150
00100
11100
21100
11100
11203
CY
CY
FT
FT
EACH
EACH
FT
SF
EACH
SY
CY
CY
LB
EACH
FT
FT
CY
MOBILIZATION
CONSTRUCTION LAYOUT STAKES AND SURVEYING
MAINTAINING TRAFFIC
LOW STRENGTH MORTAR BACKFILL
ROCK CHANNEL PROTECTION, TYPE C WITH GEOTEXTILE FABRIC
STEEL DRIP STRIP
RAILING (TWIN STEEL TUBE)
1" ELASTOMERIC BEARING PAD
1/8" PREFORMED BEARING PAD
SEMI-INTEGRAL ABUTMENT EXPANSION JOINT SEAL
1" PREFORMED EXPANSION JOINT FILLER
PRESTRESSED CONCRETE COMPOSITE BOX BEAM BRIDGE MEMBERS, LEVEL 1, CB17-48 (40'-0" LENGTH)
SEALING OF CONCRETE SURFACES (EPOXY-URETHANE)
CLASS QC1 CONCRETE, ABUTMENT INCLUDING FOOTING
CLASS QC2 CONCRETE, SUPERSTRUCTURE
EPOXY COATED REINFORCING STEEL
STEEL POINTS OR SHOES
STEEL PILES HP10X42, DRIVEN
STEEL PILES HP10X42, FURNISHED
PILE DRIVING EQUIPMENT MOBILIZATION
UNCLASSIFIED EXCAVATION
COFFERDAMS AND EXCAVATION BRACING
PORTIONS OF STRUCTURE REMOVED, OVER 20 FOOT SPAN, AS PER PLAN
LS
LS
LS
LS
LS
LS
LS
LS
LS
48
36
94
90
28
14
23
16
7
51
46
26
8,415
10
550
600
LS
148
LS
LS
3
6
2, 3
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
Q002.d
gn 5/29/2019 12:4
8:4
9
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
7
6
TY
PIC
AL S
EC
TIO
NS
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
T001.d
gn 5/29/2019 12:4
8:5
2
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
28'-0" CLEAR ROADWAY
14'-0" PLUS FIT-UP14'-0" PLUS FIT-UP
3"3"
4'-
5"
MIN. (T
YP.)
DRAWING DS-1-92 (TYP.)
SEE ODOT STANDARD
DRIP STRIP, FOR DETAILS
TST-1-99 (TYP.)
ODOT STANDARD DRAWING
RAILING, FOR DETAILS SEE
TWIN STEEL TUBE BRIDGE
| BEARING
1" BEARING PAD
CL
EA
RA
NC
E
1'-1"
MIN.
JOINT SEALER, 705.04
3:1 MAX.
TO BE FIELD DETERMINED)
MORTAR BACKFILL (LIMITS
ITEM 613 - LOW STRENGTH
PROPOSED ABUTMENT
1'-5"
BRIDGE LIMITS
PROFILE GRADE
0.083
2'-0"
2:1 M
AX.
0.083
2:1 MAX.
2'-0"
66
7
LEGEND
1
4
5
6
7
2
S
8
3
0.01560.0156
BRIDGE TRANSVERSE SECTION
ROADWAY TYPICAL SECTION
7
ROUNDING
4'-0"
ROUNDING
4'-0"
STA. 36+67.49 TO STA. 37+21.49 = 54.00'
STA. 35+71.49 TO STA. 36+25.49 = 54.00'
TYPICAL ABUTMENT SECTION
(TYP.)
4"
21 3 4 5
21 3 4 5
AT LIMITS OF FULL DEPTH REPLACEMENT
END OF BRIDGE TO MATCH EXIST. SLOPE
* TRANSITION SMOOTHLY FROM 0.0156 AT
VARIES* VARIES*
7 - CB17-48 PRESTRESSED CONCRETE BOX BEAMS = 28'-0" PLUS FIT-UP
6"
8 OF 11
1 OF 11
DIAGRAM ON SHEET
SLAB, SEE DECK THICKNESS
6" MIN. REINFORCED CONC.
PROFILE GRADE
2•" CLR.
MIN.
6"
EL. A
S
8
S602
(EPOXY-URETHANE) (TYP.)
SEALING OF CONCRETE SURFACES
(SEE SHEET )
WITH GEOTEXTILE FABRIC
ROCK CHANNEL PROTECTION, TYPE CITEM 601 -
SEEDING AND MULCHINGITEM 659 -
GUARDRAIL, TYPE MGSITEM 606 -
COURSE, TYPE 1, (448), PG64-22
1•" ASPHALT CONCRETE SURFACEITEM 441 -
COURSE, TYPE 1, (448)
2•" ASPHALT CONCRETE INTERMEDIATEITEM 441 -
12" AGGREGATE BASEITEM 304 -
SUBGRADE COMPACTIONITEM 204 -
21-S601, 20 SPA. @ 1'-4•" c/c = 27'-6"
TACK COAT (ESTIMATED AT 0.055 GAL/SY)ITEM 407 -
2'-0"
STA. 36+25.49 TO STA. 36+67.99 = 42.00'
14'-0" 14'-0"
W1 W2 W3 W4
FROM STATION TO STATION LENGTH W1 W2 W3 W4
36+82.49
36+67.49
36+10.49
35+71.49
37+21.49
36+82.49
36+25.49
36+10.49
39.00'
15.00'
15.00'
39.00'
VARIES, 14'-0" TO 5'-11"(`)
14'-0"
14'-0"
VARIES, 4'-1"(`) TO 14'-0"
VARIES, 0'-0" TO 8'-1"(`)
0'-0"
0'-0"
VARIES, 9'-11"(`) TO 0'-0"
VARIES, 0'-0" TO 7'-8"(`)
0'-0"
0'-0"
VARIES, 6'-6"(`) TO 0'-0"
VARIES, 14'-0" TO 6'-4"(`)
14'-0"
14'-0"
VARIES, 7'-6"(`) TO 14'-0"
| CONST. LONG JUDSON ROAD
| CONST. LONG JUDSON ROAD
EXPANSION JOINT SEAL
SEMI-INTEGRAL ABUTMENT
1" POLYSTYRENE
S
BEARING PADS)
(DO NOT SEAL AT LOCATIONS OF
SURFACES (EPOXY-URETHANE)
LIMITS OF SEALING OF CONCRETEITEM 512 -
AB
UT
ME
NT
DE
TAILS
8
7
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
R001.d
gn 5/29/2019 12:4
8:5
4
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
PILE NUMBER LOCATION
REAR ABUT.
FWD. ABUT.
1 THRU 5
6 THRU 10
ELEVATION
CUT-OFF
PAY LENGTH
ESTIMATED
N
N
R.A. F.A.
EL. A
EL. BEL. C EL. C
EL. B
3" 3"
PLAN
ELEVATION
6"
45° 4
5°
6"
A504
A504, E.F.
5-
A503
5-
A503
A504
A504, E.F.
1'-0
"
TYPICAL WINGWALL ELEVATION
6"
1" PEJF 1" PEJF
PROPOSED SUPERSTRUCTURE NOT SHOWN
EL. B EL. B
EL. A
LINE
GROUND
3"
c/c = 3'-6"
4-A505
4"
3"
CL
R.
C.J.
OPTIONAL
7"
3"
CL
R.
1'-3" 9"
4-A801
A502, E.F.
9" 1'-3"
4-A801
9" 9"
1'-0"
| BEARING & | PILES
3"
CL
R.
A506, N.F.
c/c = 4'-
10"
4 SP
A.
@ 1'-2•
"
EL. D EL. D
c/c = 1'-7"
2 SPA. @ 9•"
& 3-A509, F.F.
3-A508, N.F.
GROUND LINE
6"
6"
15'-9"15'-9"
34'-6"
1'-6"
1'-6"
2'-0"2'-0"
1'-6" 1'-6"
4'-4
" WIN
GW
ALL 4
'-4"
WIN
GW
ALL
3'-
0"
4'-4"
5-
A507, E.F.
28 SETS OF 2-A501
1'-0"
2'-
0"
1'-0"
6"
4-A801
1'-6"1'-6"
3'-0"
3 EQ. SPA.
4-A801
5'-
6"
MIN.
1'-4"
1'-4"
1'-8"
3 SPA. @ 1'-2"
C.J.
A502 (TYP.)
A501 (TYP.)
A401
EACH BOX BEAM
DOWEL BAR AT
1" DIA. ANCHOR
5 SPA. @ 1'-0•"(+)
= 5'-3" (TYP.)
2'-3"2 SPA. @ 6'-9" c/c PILES = 13'-6"2 SPA. @ 6'-9" c/c PILES = 13'-6"2'-3"STEEL PILE
HP10x42
R.A. (TYP.)
PILE NUMBER,
1
10
F.A. (TYP.)
PILE NUMBER,
9
2
8
3
7
4
6
5
PILE (TYP.)
HP10x42 STEEL
PILE (TYP.)
A401 AT EACH
664.77
664.69
55'
55'
ANCHOR DOWEL BARS
| BRG., | PILES, & | 1" DIA.
EL. E
A508 & A509
3-A510 LAP WITH
LOCATION EL. A EL. B EL. C EL. D EL. E
REAR ABUT.
FWD. ABUT.
ABUTMENT ELEVATIONS TABLE
SECTION A-1
7
A-1
7
STA. 36+65.99, F.A.
662.69
662.77
668.19
668.27
668.43
668.51
670.19
670.27
667.19
667.27
STA. 36+26.99, R.A.
| CONST. LONG JUDSON ROAD
JUDSON ROAD
| CONST. LONG
NOTES
EXPANSION JOINT SEAL
SEMI-INTEGRAL ABUTMENT
PSBD-2-07.
FOR DETAILS OF ANCHOR DOWEL BARS, SEE ODOT STANDARD DRAWING
INTERFERENCE WITH THE DRILLING OF ANCHOR BAR HOLES.
REINFORCING STEEL IN THE VICINITY OF THE BRIDGE SEAT TO AVOID
BRIDGE SEAT REINFORCING, SETTING ANCHORS: ACCURATELY PLACE
2.
1.
9
8
SU
PE
RS
TR
UC
TU
RE
DE
TAILS - 1
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
S001.d
gn 5/29/2019 12:4
8:5
6
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
N
6" 6"
2'-5•" 2'-5•"
| BRG. REAR ABUT. | BRG. FWD. ABUT.
MIDSPAN
DECK THICKNESS DIAGRAM
FINISHED ROADWAY SURFACE
39'-0" SPAN
40'-0" END-TO-END BOX BEAMS
6ˆ
"
6"
6"
STA. 36+65.99
14'-
0"
PL
US FIT-
UP
14'-
0"
PL
US FIT-
UP
5 SPA. @ 6'-3" c/c = 31'-3"
44'-11" BRIDGE RAILING
7 - C
B17-48 B
OX B
EA
MS = 28'-
0"
PL
US FIT-
UP
2
1
3
4
5
6
7
1'-6" 1'-6"18'-0" 18'-0"
BEAM LAYOUT PLAN
c/c
4'-4•"
c/c
4'-4•"
TYPE 1
MGS B.T.A.,
TYPE 1
MGS B.T.A.,
| DIAPHRAGM| DIAPHRAGM
| DIAPHRAGM
| BRG. REAR ABUT. | BRG. FWD. ABUT.
BACKWALL (TYP.)
ON SEMI-INTEGRAL
FLUSH MOUNTED POST
2'-9" (TYP.)1'-6" (TYP.)
1" DIA. TIE ROD (TYP.)
CAMBER
4.
3.
2.
1.
30
0
30CAMBER D .
THE BEAM SEAT ELEVATIONS ASSUME ESTIMATED
CONCRETE DECK, RAILING, ETC.) IS ‰ INCHES.
DEFLECTION DUE TO REMAINING DEAD LOAD (E.G.,
ESTIMATED CAMBER AT DAY 30 (D ) IS • INCHES.
ESTIMATED CAMBER AT DAY 0 (D ) IS • INCHES.
NOTES
FOR DECK SLAB PLAN, SEE SHEET
FOR BOX BEAM DETAILS, SEE SHEET
BRIDGE RAILING DIMENSIONS SHOWN ARE TYPICAL FOR BOTH SIDES.
3.
2.
1.
9 OF 11.
10 OF 11.
LEGEND
X BEAM NUMBER
STA. 36+26.99
| CONST. LONG JUDSON ROAD
STA. 36+26.49 (TYP.)
FLUSH MOUNTED POST
STA. 36+66.49 (TYP.)
FLUSH MOUNTED POST
SU
PE
RS
TR
UC
TU
RE
DE
TAILS - 2
9
10
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
S002.d
gn 5/29/2019 12:4
8:5
9
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
| SPAN
6"
3"
4-No. 5 BARS, FULL LENGTH
2-No. 5 BARS, FULL LENGTH
PART ELEVATION - TYPICAL BOX BEAM
BEAM IS SYMMETRICAL ABOUT | SPAN
9"
| BEAM
BEARING PAD (TYP.)
PLAIN ELASTOMERIC
6" x 12" x 1" THICK
3"
3"
2" DIA. ANCHOR DOWEL HOLE
BEARING PAD LAYOUT
| BRG.
1'-0" 1'-0" 1'-0" 1'-0"
END ELEVATION
EXTERIOR BOX BEAM
SEE NOTE 3
| C.I.P. INSERTS,
4"
4"
6"
10"
NOTES
5.
4.
3.
2.
1.
FOR BEAM LAYOUT PLAN, SEE SHEET
BEAMS.
REFER TO ODOT STANDARD DRAWING PSBD-2-07 FOR ADDITIONAL DETAILS OF BOX
AFTER BOX BEAM ERECTION.
THE OUTSIDE FACE OF EXTERIOR BOX BEAM. INSTALL No. 6 BARS INTO INSERTS
COMPATIBLE WITH THE INSERTS AND PROVIDING A PROJECTION OF 1'-3" BEYOND
AT THE LOCATIONS SHOWN AND FURNISH No. 6 BARS (STRAIGHT, EPOXY COATED)
PROVIDE CAST-IN-PLACE INSERTS ON THE OUTSIDE FACE OF EXTERIOR BOX BEAMS
DIVISION II, SECTION 18.7.2.6) IS NOT REQUIRED.
PROOF LOAD TEST (AASHTO STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES,
THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. THE LONG-TERM COMPRESSION
THE BEARINGS WERE DESIGNED IN ACCORDANCE WITH SECTION 14.7.6 (METHOD A) OF
ELASTOMERIC BEARINGS: THE ELASTOMER SHALL HAVE A HARDNESS OF 50 DUROMETER.
25.9 KTOTAL DESIGN LOAD
13.7 KLIVE LOADS
12.2 KDEAD LOADS
EXPANSION OR FIXED BEARINGBEARING DESIGN LOADS:
8 OF 11.
6" 6"
4" 4"4"
2" c/c
9 SPA. @
2" c/c
9 SPA. @
1'-5"
'N' BARS
OF EXTERIOR BEAMS
ON OUTSIDE FACE
OMIT SHEAR KEY
No. 5 BAR (TYP.)
THE 'N', 'V', & 'X' No. 4 STIRRUP BARS
SEE BEAM ELEVATION FOR SPACING OF
4'-0"
4-No. 5 BARS
'X' BARS 'V' BARS
| BRG.
8"
c/c = 9"
2 SPA. @ 4•"
CB17-48, 39'-0" SPAN
14 - •" STRANDS
2"
| BRG.
39'-0" SPAN
62-'N' BARS
31-'X' & 31-'V' BARS, ALTERNATE AS SHOWN
39 SPA. @ 10"(-) c/c = 32'-0"A B
LEGEND
ACROSS THE BEAM.
THE STIRRUPS AND SPACED UNIFORMLY
USED, THEY SHALL BE LOCATED ON TOP OF
FABRICATOR'S OPTION. IF No. 6 BARS ARE
4 BENT-UP STRANDS AT EACH BEAM END,
C = PROVIDE 4-No. 6 EPOXY COATED BARS OR
B = 4 SPA. @ 6" c/c = 2'-0"
A = 7 SPA. @ 3" c/c = 1'-9"
C
11
10
NOTES
STATION
14.00' LTOF DECK
LEFT EDGE
OF DECK
RIGHT EDGE
GRADE
PROFILE
| BRG. R.A. 0.50 SPAN | BRG. F.A.
14.00' RT
0.00'
LOCATION 0.25 SPAN 0.75 SPAN
STATION
STATION
6 OF 11.
SCREED EL.
FINAL EL.
SCREED EL.
FINAL EL.
SCREED EL.
FINAL EL.
SU
PE
RS
TR
UC
TU
RE
DE
TAILS - 3
3.
2.
1.
DECK ELEVATIONS TABLE
LEGEND
P
R
SUPERSTRUCTURE
ITEM 511 - CLASS QC2 CONCRETE,
1" POLYSTYRENE, INCLUDE FOR PAYMENT WITH
PER ODOT STANDARD DRAWING TST-1-99
FLUSH MOUNTED POST ON INTEGRAL BACKWALL
FOR TRANSVERSE SECTION, SEE SHEET
OCCURRED.
ALL ANTICIPATED DEAD LOAD DEFLECTIONS HAVE
REPRESENT THE DECK SURFACE LOCATION AFTER
FINAL DECK SURFACE ELEVATIONS SHOWN
OTHER ANTICIPATED DEAD LOADS.
DEFLECTIONS CAUSED BY DECK PLACEMENT AND
THEORETICAL DECK SURFACE LOCATION PRIOR TO
SCREED ELEVATIONS SHOWN REPRESENT THE
670.29
670.29
36+26.99
670.51
670.51
36+26.99
670.29
670.29
36+26.99
670.32
670.33
36+36.74
670.54
670.55
36+36.74
670.32
670.33
36+36.74
670.32
670.34
36+46.49
670.54
670.56
36+46.49
670.32
670.34
36+46.49
670.28
670.29
36+56.24
670.50
670.51
36+56.24
670.28
670.29
36+56.24
670.21
670.21
36+65.99
670.43
670.43
36+65.99
670.21
670.21
36+65.99
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
S003.d
gn 5/29/2019 12:4
9:0
1
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK
20 SPA. @ 1'-4•" c/c = 27'-6"
21-S601 & 21-S603,
20 SPA. @ 1'-4•" c/c = 27'-6"
21-S601 & 21-S603,
57-S602, 56 SPA. @ 9"(-) c/c = 41'-6"3"
DECK SLAB PLAN
3"
3"
3"
3"
3"
STA. 36+65.99
3-S604 3-S604
*
| BRG. REAR ABUT. | BRG. FWD. ABUT.
2'-10" LAP (TYP.)
LEFT EDGE OF DECK
RIGHT EDGE OF DECK
S-1
10
S-1
10
S-2
10
S-2
10
(TYP.)
2'-0"
= 1'-6", TYP. EACH CORNER
* 3-S605, 2 SPA. @ 9" c/c
STA. 36+26.99
N
| CONST. LONG JUDSON ROAD
1'-6"14'-0"
15'-6"
3"1'-0"
S501
1" PEJF
S605
S606, LAP S604
S604, F.F.
1'-6"S601
(TYP.)S602
SECTION S-1
10
SECTION S-2
10
| BRG.
S603, LAP TO S601
9 OF 11
3-S604
P
R
P
BOX BEAM DETAILS NOT SHOWN FOR CLARITY
TYP. FOR ALL CORNERS OF DECK
INTEGRAL BACKWALL
(SEE SHEET )
4 BENT-UP STRANDS
4-No. 6 BARS OR
| CONST. LONG JUDSON ROAD
JOINT SEAL
EXPANSION
ABUTMENT
SEMI-INTEGRAL
REIN
FO
RCIN
G S
TE
EL LIS
T
REINFORCING STEEL LIST
MARK NO. LENGTH WEIGHT TYPEDIMENSIONS
A B C D E INC.
SERIES
REINFORCING STEEL LIST
MARK NO. LENGTH WEIGHT TYPEDIMENSIONS
A B C D E INC.
SERIES
BENDING DIAGRAMS
REINFORCING STEEL NOTES
REAR ABUTMENT SUPERSTRUCTURE
ALL REINFORCING STEEL SHALL BE EPOXY COATED.
NUMBER. FOR EXAMPLE, A501 IS A #5 BAR SIZE.
THE FIRST DIGIT OF EACH MARK INDICATES THE BAR SIZE
THE BAR SIZE NUMBER IS INDICATED IN THE 'MARK' COLUMN.
TYPE 'STR' INDICATES A STRAIGHT BAR.
ALL DIMENSIONS ARE OUT TO OUT.
SERIES BARS - EACH BAR VARIES BY TABULATED AMOUNT.
5.
4.
3.
2.
1.
FWD. ABUTMENT
C
AB
C
BA
12
11
A801
A510
A509
A508
A507
A506
A505
A504
A503
A502
A501
A401
8
6
6
6
10
2
8
6
10
6
56
10
TOTAL
31'-2"
3'-2"
3'-9"
4'-2"
5'-4"
7'-2"
16'-2"
8'-9"
8'-2"
31'-2"
10'-1"
9'-0"
1,925
666
20
23
26
56
15
135
55
85
195
589
60
LBS
STR
1
STR
STR
STR
STR
3
2
34
STR
2
3
1'-8"
7'-2"
5'-0"
1'-3"
2'-8"
2'-6"
2'-0"
1'-3"
3'-10"
S606
S605
S604
S603
S602
S601
S501
12
12
6
42
57
42
8
TOTAL
5'-4"
5'-9"
30'-8"
4'-1"
27'-8"
22'-3"
7'-0"
4,565
96
104
276
258
2,369
1,404
58
LBS
2
1
STR
1
STR
STR
3
2'-10"
4'-4"
2'-10"
1'-8"
1'-8"
1'-7"
1'-5"
1'-7"
1'-2"
2'-0"
1'-3"
3'-10"
1'-8"
7'-2"
5'-0"
1'-3"
2'-8"
2'-6"
LBS
STR
1
STR
STR
STR
STR
3
2
34
STR
2
3
1,925
666
20
23
26
56
15
135
55
85
195
589
60
TOTAL
31'-2"
3'-2"
3'-9"
4'-2"
5'-4"
7'-2"
16'-2"
8'-9"
8'-2"
31'-2"
10'-1"
9'-0"
8
6
6
6
10
2
8
6
10
6
56
10
A801
A510
A509
A508
A507
A506
A505
A504
A503
A502
A501
A401
1'-8"
0'-8"
2'-0"
2'-5"
3'-10"
1'-9"
1'-8"
0'-8"
2'-0"
2'-5"
3'-10"
1'-9"
TYPE 34TYPE-3
A
B
B
A
TYPE-1 TYPE-2
A
B
C
JA
M
DESIG
NE
D
CH
EC
KE
DR
EVIS
ED
DR
AW
NR
EVIE
WE
DD
AT
E
ST
RU
CT
UR
E FIL
E
NU
MB
ER
8745731
MJL
pw:\\
PW
1.dlz
corp.c
om:D
LZ\
Docu
ments\
Projects\
2018\
1822\
1013\
Desig
n\
Structures\
Sheets\
TR7
9B_
004
0S
L001.d
gn 5/29/2019 12:4
9:0
3
PM jmiller
BRID
GE
NO.
WO
O-
TR79
B-0040
05/29/19
JA
M
PA
T1
SE
AG
AT
E, S
UIT
E 610
* T
OL
ED
O,
OHIO 43604
11
12
WO
O-
TR
79
B-0.4
0
LO
NG J
UD
SO
N R
OA
D (T.R. 79
B)
OV
ER
WES
T B
RA
NC
H T
ON
TO
GA
NY C
RE
EK