proposed development of an all-weather pitch at coláiste … · 2018-04-04 · the proposal uses...
TRANSCRIPT
Parks & Landscape Services Section, Municipal Services Department
Proposed Development of an All-Weather Pitch at Coláiste Eoin/Íosagain
PC/PKS/01/18
Appendix 1 – Floodlighting Design & Report
Proposed Floodlighting at Colaiste Eoin Blackrock, Co. Dublin
Sports Lighting Proposal Compiled by Neil McSherry BEng MIET
16th March 2018 Eoin O'Brien Senior Executive Parks Superintendent, Landscape Architect, MILI Parks and Landscape Services, Municipal Services Department Dún Laoghaire Rathdown County Council, Marine Road, Dún Laoghaire, Co. Dublin, Ireland
RE: Proposed Floodlighting at Colaiste Eoin Dear Mr O’Brien, As instructed, Musco Lighting Europe has undertaken the sports lighting design for the proposed GAA Pitch. Our design is prepared in compliance with:
Chartered Institute of Building Services Engineers Lighting Guide 4: Sports Lighting (CIBSE LG4)
Institute of Lighting Professionals (ILP) Guidance Notes for the Reduction of Obtrusive Light GN01:2011
Terminology In order to ensure clarity and understanding, some typical floodlighting and project specific terms have been defined/explained to assist in the reading and evaluation of this document and the design documents:
Horizontal Illuminance - the level of light at a given point measured on a
horizontal plane, such as the sports pitch, footpath, or a desk. Often used in sports applications as a visual and playability evaluation of light. Measured by holding the light meter horizontal to the ground, facing toward the sky.
Vertical Illuminance (Ev) - the level of light at a given point measured on a vertical plane, such as a wall, the side of a building, or window. Measured by holding the light meter vertically towards the light source.
Lux - unit of measure for illumination.
o Sunny Day = 50,000 - 150,000 lux o Overcast Day = 5,000 - 10,000 lux o Major sports stadium = 2,000 - 3,000 lux o Office lighting = 300 - 500 lux o Roadway lighting = 15 - 30 lux o Sunset = 10 lux
Luminaire - Light fitting/floodlight
Uniformity (Emin/Eav) - Evaluation of how well distributed the light is across a given
area. Expressed as a ratio of minimum point divided by the average of all points.
Metal Halide (HID) - Traditional lamp technology used in sports lighting. Combines specific gases and electricity to produce light.
LED - (Light Emitting Diode) - Light is produced electronically using a
semiconductor
The objective of the design was to produce a system compliant with CIBSE LG4 as follows: Class I GAA - 500 lux Horizontal average, 0.7 Emin/Eav uniformity In accordance with the ILP Guidance Notes for the Reduction of Obtrusive Light
GN01:2011 the local area can be classified as a suburban environment and therefore Environmental Zone ‘E3’ applies. E3 areas are defined for lighting purposes as ‘Medium District Brightness Areas’ (Table 1) and typically include suburban locations. In accordance with Table 2, Light Intrusion into Windows is limited to 10 lux vertical (Ev). Musco’s design is compliant with this requirement with a maximum Light Intrusion into Windows of 8.73 lux vertical (Ev) as demonstrated on page 7 of the lighting design document 190498D. The developed design is optimised for compliance with ILP Guidance Notes for the Reduction of Obtrusive Light GN01:2011 by minimising obtrusive light; Spill, sky glow and glare. This is achieved in the following ways:
1. Column height, number of columns and aiming angles
Choosing appropriate number of columns and column heights is key to the overall quality of the lighting design. Based on the size of the pitch, the sport being played, the competition level, and the use of the floodlighting system (televised or non-televised); column number and height requirements must be accurately assessed to ensure the aiming angle of the floodlight onto the pitch is at an appropriate degree to maintain good playability, control glare, and reduce spill light on adjoining landscape or properties. See the diagram below:
GAA is by its nature is an aerial sport, in particular the sliotar is a fast moving small object,
which requires adequate levels of light both at pitch level and at height. In order to provide
adequate light levels for this type of sport, correct height of column needs to be carefully
considered. Shorter columns with shallow aiming angles, will not provide light for the ball
in flight, will cause unplayable levels of glare and will increase spill to the adjacent roads
and residences. Choosing columns at an adequate height - proposed to be 18m for the
Musco design will allow the aiming of the floodlights to be at a more downward angle to
the pitch, thus minimising spill and glare. This height will also facilitate the ball in flight in
accordance with the ILP Guidance Notes on the Reduction of Obtrusive Light GN01:2011
(page 5). This will ensure good playability and consideration for the health and safety of
the players.
2. Class Leading Light Control
The proposal uses Musco's Light Structure Green TLC-LED-1150 system. The Musco LED system luminaire is markedly different in design than Musco’s metal halide system. While the traditional metal halide luminaire was efficient and provided class leading light control, the Musco LED luminaire has advanced light control even further. Note the two images below.
Musco is a leading international sports lighting company with thousands of installations
worldwide. We are leaders in the development of LED technology for sports lighting
applications. Some high profile installations in the UK include:
Twickenham Stadium
Emirates Stadium
Wimbledon Centre Court
Tottenham Hotspur – New Stadium Development
To following images of completed projects illustrate the enhanced spill control of the LED
system over traditional metal halide technologies.
PHOTOS OF THE MUSCO LED SYSTEM FOR COMPARISON
MILLFIELD SCHOOL
GLASTONBURY, ENGLAND
Installation of Musco LED system on two hockey pitches. Light levels are 350 lux & 500 lux.
Fulham FC Training Arsenal Training Academy
3. Patented Technological Advancements
The Musco LED system is designed to perform for more than ten times as long as
traditional metal halide system (L90 51,000 hours). This means less maintenance
required, thus less disturbance on the surrounding area. Musco offers a fully inclusive 10
year warranty with the entire system, so it will never fall into disrepair.
The environmental impact with regard to energy consumption and CO2 emissions is
significantly reduced with the proposed LED system. Analysis of both technologies shows
the LED system will reduce energy and CO2 emissions by around 66% over 2kW metal
halide systems.
In addition metal halide systems apply a maintenance factor, typically of 0.8 to counteract
light depreciation. It should be noted that this will result in initial light levels including spill
being 25% higher than the average designed lighting level on metal halide solutions.
Attachments
1. 18599D Lighting Design
2. TLC-LED-1150W Luminaire Data Sheet
PROJECT SUMMARY
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
Colaiste Eoin SchoolBlackrock,LEINSTER
Ligh ng System Pole / Fixture Summary
Pole ID Pole Height Mtg Height Fixture Qty Luminaire Type Load GroupP1, P3-P4, P6 18.0 18.0 7 TLC-LED-1150 8.05 kW A
P2, P5 18.0 18.0 6 TLC-LED-1150 6.90 kW A6 40 46.00 kW
Group SummaryGroup Description Load Fixture Qty
A GAA Pitch 46.0 kW 40
Fixture Type SummaryType Source Wattage Lumens L90 L80 L70 Quantity
TLC-LED-1150 LED 5700K - 75 CRI 1150W 121,000 >51,000 >51,000 >51,000 40
Light Level Summary Calculation Grid Summary
IlluminationGrid Name Calculation Metric Ave Min Max Min/Max Min/Ave Groups Fixture Qty
100m Spill Blanket Horizontal 3.32 0 106 0.00 0.00 A 40100m Spill Blanket Max Vert Illuminance (by Light Bank) 4.46 0 186 0.00 0.00 A 40
GAA Pitch Horizontal Illuminance 510 436 676 0.65 0.86 A 40LTW 1 Max Vertical Illuminance Metric 0 0 0 0.00 A 40
LTW 2 Max Vertical Illuminance Metric 0.14 0 0.85 0.00 0.00 A 40LTW 3 Max Vertical Illuminance Metric 1.22 0 8.73 0.00 0.00 A 40
LTW 4 Max Vertical Illuminance Metric 0 0 0 0.00 A 40Soccer Horizontal Illuminance 512 436 676 0.65 0.85 A 40
0.00
0.00
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
437
487
480
443
507
502
446
557
574
598
556
608
593
584
506
531
507
438
522
575
515
442
593
464
436
484
608
448
447
514
459
460
460
521
458
458
462
541
506
543
468
467
537
486
532
475
529
484
541
465
472
545
500
534
459
465
458
524
454
453
445
501
454
444
587
456
438
471
566
438
497
512
499
464
539
539
486
535
600
671
601
660
676
550
446
625
560
443
501
625
448
28.9
0IS Utilit
y Cov
er
G
G
Sign
AV
65
Mh
LS
LS
LS38
.0m
0.0m
38.0
m
54.8m
38.0
m
0.0m
38.0
m
54.8m
38.0
m
54.8m
38.0
m
54.8m
P2P1
P5P6
P3
P4
SCALE 1 : 500
0 20m 40m
EQUIPMENT LIST FOR AREAS SHOWNPole Luminaires
QTY LOCATION SIZE GRADEELEVATION
MOUNTINGHEIGHT
LUMINAIRETYPE
QTY /POLE
THISGRID
OTHERGRIDS
4 P1, P3-P4P6
18m - 18m TLC-LED-1150 7 7 0
2 P2, P5 18m - 18m TLC-LED-1150 6 6 06 TOTALS 40 40 0
Pole loca on(s) dimensions are rela veto 0,0 reference point(s)
Colaiste Eoin SchoolBlackrock,LEINSTER
GRID SUMMARYName: GAA Pitch
Size: 120.0m x 64.0mSpacing: 10.0m x 10.0m
Height: 1.0m above grade
ILLUMINATION SUMMARYMAINTAINED HORIZONTAL LUX
En re GridGuaranteed Average: 500
Scan Average: 509.82Maximum: 676Minimum: 436
Guaranteed Min / Avg: 0.7Min / Avg: 0.86
Min / Max: 0.65UG (adjacent pts): 1.40
CU: 0.95No. of Points: 91
LUMINAIRE INFORMATIONColor / CRI: 5700K - 75 CRI
Luminaire Output: 121,000 lumensNo. of Luminaires: 40
Total Load: 46.0 kWLumen Maintenance
Luminaire Type L90 hrs L80 hrs L70 hrsTLC-LED-1150 >51,000 >51,000 >51,000
Reported per TM-21-11. See luminaire datasheet for details.
Guaranteed Performance: The ILLUMINATION describedabove is guaranteed per your MuscoWarranty document and includes a 0.95dirt deprecia on factor.
Field Measurements: Individual eld measurements may vary fromcomputer-calculated predic ons and should be takenin accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing.
Installa on Requirements: Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design loca ons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
28.9
0IS Utilit
y Cov
er
G
G
Sign
AV
65
Mh
LS
LS
LS
557
574
598
556
608
593
584
506
531
507
438
522
575
515
442
593
464
436
484
608
448
447
514
459
460
460
521
458
458
462
541
506
543
468
467
537
486
532
475
529
484
541
465
472
545
500
534
459
465
458
524
454
453
445
501
454
444
587
456
438
471
566
438
497
512
499
464
539
539
486
535
600
671
601
660
676
550
38.0
m
0.0m
38.0
m
54.8m
38.0
m
0.0m
38.0
m
54.8m
38.0
m
54.8m
38.0
m
54.8m
P2P1
P5P6
P3
P4
SCALE 1 : 500
0 20m 40m
EQUIPMENT LIST FOR AREAS SHOWNPole Luminaires
QTY LOCATION SIZE GRADEELEVATION
MOUNTINGHEIGHT
LUMINAIRETYPE
QTY /POLE
THISGRID
OTHERGRIDS
4 P1, P3-P4P6
18m - 18m TLC-LED-1150 7 7 0
2 P2, P5 18m - 18m TLC-LED-1150 6 6 06 TOTALS 40 40 0
Pole loca on(s) dimensions are rela veto 0,0 reference point(s)
Colaiste Eoin SchoolBlackrock,LEINSTER
GRID SUMMARYName: Soccer
Size: 100.0m x 64.0mSpacing: 10.0m x 10.0m
Height: 1.0m above grade
ILLUMINATION SUMMARYMAINTAINED HORIZONTAL LUX
En re GridGuaranteed Average: 500
Scan Average: 512.25Maximum: 676Minimum: 436
Guaranteed Min / Avg: 0.7Min / Avg: 0.85
Min / Max: 0.65UG (adjacent pts): 1.36
CU: 0.80No. of Points: 77
LUMINAIRE INFORMATIONColor / CRI: 5700K - 75 CRI
Luminaire Output: 121,000 lumensNo. of Luminaires: 40
Total Load: 46.0 kWLumen Maintenance
Luminaire Type L90 hrs L80 hrs L70 hrsTLC-LED-1150 >51,000 >51,000 >51,000
Reported per TM-21-11. See luminaire datasheet for details.
Guaranteed Performance: The ILLUMINATION describedabove is guaranteed per your MuscoWarranty document and includes a 0.95dirt deprecia on factor.
Field Measurements: Individual eld measurements may vary fromcomputer-calculated predic ons and should be takenin accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing.
Installa on Requirements: Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design loca ons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
28.9
0IS
30.5
9
30.5
3
30.9
5
38.1
4
30.0
4
FH
FH
FH
Utilit
y Cov
er
Utilit
y Cov
er
G
G
G
G
G
G
G
G
Sign
Sign
Sign
AV
59
80
41
84-9
8
3
UND
CR UND
34
40
45
78
73
40A
35
50
79
7
71
50-6
8
77
42
4946
74
33
72
55
69-8
3
88
60
39
66
10
Mh
H
H
Mh
THORNWOOD
Scho
ol
St. Thomas'
Wood
Belfie
ldPa
rk
6
54
LAPW
ING
1-2
9
2
SANDERLING 1-48
4
TUR
NST
ON
E 1-
41
3 1
HERON 1-38
65
Mh
H
H
Mh
HM
h
Mh
Mhs
H
H
Mhs
Mhs
Mh
Mh
Mhs
Mhs
Mhs
Mh
Mh
Mh
H
H Mh
Mhs
H
Mh
Mhs
Mh
Mhs
Mh
H
Mhs
H
Mh
LS
LS
LS
LS
LS
LS
LS
LS
H
H
Mh
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LSLS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LSLS
LS
LS
LS
ST HELEN'S WOOD
ST HELEN'S WOOD
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
30.1
28.0
34.5
26.2
32.4
BM 2
7.53
STILLORGAN ROADSTILLORGAN ROAD
GREYGATESGREYGATES
2.0
5.0
10.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
4
7
5
7
3
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
3
28
90
80
62
80
81
26
3
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
55
57
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
81
86
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
83
91
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
33
41
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
26
30
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
82
85
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
104
106
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
83
86
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
28
31
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
36
43
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
85
89
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
78
80
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
55
68
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
9
70
103
61
63
64
8
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
3
5
2
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
38.0
m
0.0m
38.0
m
54.8m
38.0
m
0.0m
38.0
m
54.8m
38.0
m
54.8m
38.0
m
54.8m
P2P1
P5P6
P3
P4
SCALE 1 : 1250
0 13m 25m
EQUIPMENT LIST FOR AREAS SHOWNPole Luminaires
QTY LOCATION SIZE GRADEELEVATION
MOUNTINGHEIGHT
LUMINAIRETYPE
QTY /POLE
THISGRID
OTHERGRIDS
4 P1, P3-P4P6
18m - 18m TLC-LED-1150 7 7 0
2 P2, P5 18m - 18m TLC-LED-1150 6 6 06 TOTALS 40 40 0
Pole loca on(s) dimensions are rela veto 0,0 reference point(s)
Colaiste Eoin SchoolBlackrock,LEINSTER
GRID SUMMARYName: 100m Spill Blanket
Size: 100.0m x 64.0mSpacing: 10.0m x 10.0m
Height: 1.0m above grade
ILLUMINATION SUMMARYMAINTAINED HORIZONTAL LUX
En re GridScan Average: 3.32
Maximum: 106Minimum: 0
No. of Points: 800LUMINAIRE INFORMATION
Color / CRI: 5700K - 75 CRILuminaire Output: 121,000 lumensNo. of Luminaires: 40
Total Load: 46.0 kWLumen Maintenance
Luminaire Type L90 hrs L80 hrs L70 hrsTLC-LED-1150 >51,000 >51,000 >51,000
Reported per TM-21-11. See luminaire datasheet for details.
Guaranteed Performance: The ILLUMINATION describedabove is guaranteed per your MuscoWarranty document and includes a 0.95dirt deprecia on factor.Field Measurements: Individual eld measurements may vary fromcomputer-calculated predic ons and should be takenin accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing.
Installa on Requirements: Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design loca ons.
NOTES: Contour lines shown at 10/5/2 lux.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
28.9
0IS
30.5
9
30.5
3
30.9
5
38.1
4
30.0
4
FH
FH
FH
Utilit
y Cov
er
Utilit
y Cov
er
G
G
G
G
G
G
G
G
Sign
Sign
Sign
AV
59
80
41
84-9
8
3
UND
CR UND
34
40
45
78
73
40A
35
50
79
7
71
50-6
8
77
42
4946
74
33
72
55
69-8
3
88
60
39
66
10
Mh
H
H
Mh
THORNWOOD
Scho
ol
St. Thomas'
Wood
Belfie
ldPa
rk
6
54
LAPW
ING
1-2
9
2
SANDERLING 1-48
4
TUR
NST
ON
E 1-
41
3 1
HERON 1-38
65
Mh
H
H
Mh
HM
h
Mh
Mhs
H
H
Mhs
Mhs
Mh
Mh
Mhs
Mhs
Mhs
Mh
Mh
Mh
H
H Mh
Mhs
H
Mh
Mhs
Mh
Mhs
Mh
H
Mhs
H
Mh
LS
LS
LS
LS
LS
LS
LS
LS
H
H
Mh
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LSLS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LSLS
LS
LS
LS
ST HELEN'S WOOD
ST HELEN'S WOOD
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
30.1
28.0
34.5
26.2
32.4
BM 2
7.53
STILLORGAN ROADSTILLORGAN ROAD
GREYGATESGREYGATES
2.0
5.0
10.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
4
6
15
7
13
6
5
3
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
8
31
129
126
79
124
112
27
11
4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
4
57
60
7
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
5
85
90
8
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
5
101
112
9
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
7
49
63
10
2
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
7
33
43
10
2
1
0
0
0
0
0
0
0
0
0
0
0
0
1
2
7
89
89
9
3
1
0
0
0
0
0
0
0
0
0
0
0
0
1
2
8
108
110
10
3
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
8
87
90
9
3
1
0
0
0
0
0
0
0
0
0
0
0
0
1
2
9
39
42
10
3
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
9
54
64
9
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
6
104
108
6
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
3
80
82
3
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
56
70
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
9
104
186
110
95
93
10
3
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
5
13
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
38.0
m
0.0m
38.0
m
54.8m
38.0
m
0.0m
38.0
m
54.8m
38.0
m
54.8m
38.0
m
54.8m
P2P1
P5P6
P3
P4
SCALE 1 : 1250
0 13m 25m
EQUIPMENT LIST FOR AREAS SHOWNPole Luminaires
QTY LOCATION SIZE GRADEELEVATION
MOUNTINGHEIGHT
LUMINAIRETYPE
QTY /POLE
THISGRID
OTHERGRIDS
4 P1, P3-P4P6
18m - 18m TLC-LED-1150 7 7 0
2 P2, P5 18m - 18m TLC-LED-1150 6 6 06 TOTALS 40 40 0
Pole loca on(s) dimensions are rela veto 0,0 reference point(s)
Colaiste Eoin SchoolBlackrock,LEINSTER
GRID SUMMARYName: 100m Spill Blanket
Size: 100.0m x 64.0mSpacing: 10.0m x 10.0m
Height: 1.0m above grade
ILLUMINATION SUMMARYMAINTAINED MAX VERTICAL LUX
En re GridScan Average: 4.46
Maximum: 186Minimum: 0
No. of Points: 800LUMINAIRE INFORMATION
Color / CRI: 5700K - 75 CRILuminaire Output: 121,000 lumensNo. of Luminaires: 40
Total Load: 46.0 kWLumen Maintenance
Luminaire Type L90 hrs L80 hrs L70 hrsTLC-LED-1150 >51,000 >51,000 >51,000
Reported per TM-21-11. See luminaire datasheet for details.
Guaranteed Performance: The ILLUMINATION describedabove is guaranteed per your MuscoWarranty document and includes a 0.95dirt deprecia on factor.Field Measurements: Individual eld measurements may vary fromcomputer-calculated predic ons and should be takenin accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing.
Installa on Requirements: Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design loca ons.
NOTES: Contour lines shown at 10/5/2 lux.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
30.5
3
30.9
5
FH
G
80
Spor
tsGr
ound
85
20
78
73
7977
97
74
72
96
88
95
86
98
H
87
10773
-80
Mhs M
hs
H
Mh
H
H
Mhs
Mh
Mh
Mh
Mhs
H
Mh
H
Mhs
LS
HLS
LS
LS
LS
LS
LS
LS
LS
LS
LS
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.000.00
0.00
0.00
0.000.00
0.00
0.00
0.00
0.00
0.00
0.00
SCALE 1: 500
0 20m 40m
EQUIPMENT LIST FOR AREAS SHOWNPole Luminaires
QTY LOCATION SIZE GRADEELEVATION
MOUNTINGHEIGHT
LUMINAIRETYPE
QTY /POLE
THISGRID
OTHERGRIDS
4 P1, P3-P4P6
18m - 18m TLC-LED-1150 7 7 0
2 P2, P5 18m - 18m TLC-LED-1150 6 6 06 TOTALS 40 40 0
Pole loca on(s) dimensions are rela veto 0,0 reference point(s)
Colaiste Eoin SchoolBlackrock,LEINSTER
GRID SUMMARYName: LTW 1
Spacing: 5.0mHeight: 1.5m above grade
ILLUMINATION SUMMARYMAINTAINED MAX VERTICAL LUX
En re GridScan Average: 0.0000
Maximum: 0.00Minimum: 0.00
No. of Points: 23LUMINAIRE INFORMATION
Color / CRI: 5700K - 75 CRILuminaire Output: 121,000 lumensNo. of Luminaires: 40
Total Load: 46.0 kWLumen Maintenance
Luminaire Type L90 hrs L80 hrs L70 hrsTLC-LED-1150 >51,000 >51,000 >51,000
Reported per TM-21-11. See luminaire datasheet for details.
Guaranteed Performance: The ILLUMINATION describedabove is guaranteed per your MuscoWarranty document and includes a 0.95dirt deprecia on factor.Field Measurements: Individual eld measurements may vary fromcomputer-calculated predic ons and should be takenin accordance with IESNA RP-6-15.Electrical System Requirements: Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing.Installa on Requirements: Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design loca ons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
30.9
5
FH
5941
40
45
78
73
40A
79
71
77
42
74
72
60
39
66
H
H
65
H
Mh
Mhs
HM
hs
Mh
Mh
Mhs
H
Mhs
Mh
Mh
LS
LSLS
LS
LS
LS
LS
ST HELEN'S WOOD
ST HELEN'S WOOD
LS
LSLS
0.00
0.00
0.000.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.06
0.11
0.16
0.30
0.49
0.58
0.85
P2 P3
SCALE 1 : 500
0 20m 40m
EQUIPMENT LIST FOR AREAS SHOWNPole Luminaires
QTY LOCATION SIZE GRADEELEVATION
MOUNTINGHEIGHT
LUMINAIRETYPE
QTY /POLE
THISGRID
OTHERGRIDS
4 P1, P3-P4P6
18m - 18m TLC-LED-1150 7 7 0
2 P2, P5 18m - 18m TLC-LED-1150 6 6 06 TOTALS 40 40 0
Pole loca on(s) dimensions are rela veto 0,0 reference point(s)
Colaiste Eoin SchoolBlackrock,LEINSTER
GRID SUMMARYName: LTW 2
Spacing: 5.0mHeight: 1.5m above grade
ILLUMINATION SUMMARYMAINTAINED MAX VERTICAL LUX
En re GridScan Average: 0.1422
Maximum: 0.85Minimum: 0.00
No. of Points: 18LUMINAIRE INFORMATION
Color / CRI: 5700K - 75 CRILuminaire Output: 121,000 lumensNo. of Luminaires: 40
Total Load: 46.0 kWLumen Maintenance
Luminaire Type L90 hrs L80 hrs L70 hrsTLC-LED-1150 >51,000 >51,000 >51,000
Reported per TM-21-11. See luminaire datasheet for details.
Guaranteed Performance: The ILLUMINATION describedabove is guaranteed per your MuscoWarranty document and includes a 0.95dirt deprecia on factor.Field Measurements: Individual eld measurements may vary fromcomputer-calculated predic ons and should be takenin accordance with IESNA RP-6-15.Electrical System Requirements: Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing.Installa on Requirements: Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design loca ons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
5941
40
45
40A
5042
4946
5560
66
H
THORNWOOD
54
LAPW
ING
1-2
9
24
TUR
NST
ON
E 1-
41
3 1
65
H
Mhs
H
Mhs
Mhs
Mhs
Mhs
Mh
Mh
LS
LS
Mh
LS
LS
LS
LS
LS
LS
LS
LS
LS
6.85
7.84
8.734.87 2.24
0.90 0.30 0.08 0.01 0.000.00
0.00 0.000.00
0.00 0.000.00
0.00 0.00 0.000.00 0.00
0.00 0.000.00
0.00
P3
P4
SCALE 1 : 500
0 20m 40m
EQUIPMENT LIST FOR AREAS SHOWNPole Luminaires
QTY LOCATION SIZE GRADEELEVATION
MOUNTINGHEIGHT
LUMINAIRETYPE
QTY /POLE
THISGRID
OTHERGRIDS
4 P1, P3-P4P6
18m - 18m TLC-LED-1150 7 7 0
2 P2, P5 18m - 18m TLC-LED-1150 6 6 06 TOTALS 40 40 0
Pole loca on(s) dimensions are rela veto 0,0 reference point(s)
Colaiste Eoin SchoolBlackrock,LEINSTER
GRID SUMMARYName: LTW 3
Spacing: 5.0mHeight: 1.5m above grade
ILLUMINATION SUMMARYMAINTAINED MAX VERTICAL LUX
En re GridScan Average: 1.2238
Maximum: 8.73Minimum: 0.00
No. of Points: 26LUMINAIRE INFORMATION
Color / CRI: 5700K - 75 CRILuminaire Output: 121,000 lumensNo. of Luminaires: 40
Total Load: 46.0 kWLumen Maintenance
Luminaire Type L90 hrs L80 hrs L70 hrsTLC-LED-1150 >51,000 >51,000 >51,000
Reported per TM-21-11. See luminaire datasheet for details.
Guaranteed Performance: The ILLUMINATION describedabove is guaranteed per your MuscoWarranty document and includes a 0.95dirt deprecia on factor.Field Measurements: Individual eld measurements may vary fromcomputer-calculated predic ons and should be takenin accordance with IESNA RP-6-15.Electrical System Requirements: Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing.Installa on Requirements: Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design loca ons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
2
121
10
CR UND
7
16
3
11
14
Mh
H
Mh
6
Mhs
Mh
H
Mhs
H
LS
LS
LS
LS
LS
RISERISE
LS
LS
LS
34.5
32.4
GREYGATESGREYGATES
0.000.00
0.000.000.00
0.000.00
0.000.000.000.000.00
0.000.000.000.000.000.000.000.00
0.000.000.000.000.000.000.00
0.00
0.000.00
0.000.000.000.000.000.00
0.000.00
0.000.000.00
SCALE 1 : 600
0 20m 40m
EQUIPMENT LIST FOR AREAS SHOWNPole Luminaires
QTY LOCATION SIZE GRADEELEVATION
MOUNTINGHEIGHT
LUMINAIRETYPE
QTY /POLE
THISGRID
OTHERGRIDS
4 P1, P3-P4P6
18m - 18m TLC-LED-1150 7 7 0
2 P2, P5 18m - 18m TLC-LED-1150 6 6 06 TOTALS 40 40 0
Pole loca on(s) dimensions are rela veto 0,0 reference point(s)
Colaiste Eoin SchoolBlackrock,LEINSTER
GRID SUMMARYName: LTW 4
Spacing: 5.0mHeight: 1.5m above grade
ILLUMINATION SUMMARYMAINTAINED MAX VERTICAL LUX
En re GridScan Average: 0.0000
Maximum: 0.00Minimum: 0.00
No. of Points: 41LUMINAIRE INFORMATION
Color / CRI: 5700K - 75 CRILuminaire Output: 121,000 lumensNo. of Luminaires: 40
Total Load: 46.0 kWLumen Maintenance
Luminaire Type L90 hrs L80 hrs L70 hrsTLC-LED-1150 >51,000 >51,000 >51,000
Reported per TM-21-11. See luminaire datasheet for details.
Guaranteed Performance: The ILLUMINATION describedabove is guaranteed per your MuscoWarranty document and includes a 0.95dirt deprecia on factor.Field Measurements: Individual eld measurements may vary fromcomputer-calculated predic ons and should be takenin accordance with IESNA RP-6-15.Electrical System Requirements: Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing.Installa on Requirements: Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design loca ons.
EQUIPMENT LAYOUT
Not to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2018 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Nour Kerolos • File #190498D • 15-Mar-18
GAA Pitch120.0m x 64.0m
28.9
0IS
30.5
9
30.5
3
30.9
5
38.1
4
30.0
4
FH
FH
Utilit
y Cov
er
Utilit
y Cov
er
G
G
G
G
G
G
G
G
Sign
Sign
Sign
AV
59
41
CR UND
40
45
78
73
40A
35
71
42
74
72
5560
39
66
Mh
H
H
Mh
THORNWOOD
Scho
ol
St. Thomas' W
ood
2
SANDERLING 1-48
4
TUR
NST
ON
E 1-
41
3 1
65
Mh
H
Mh
Mh
Mhs
HM
hs
Mh
Mh
Mhs
Mhs
Mh
H
Mhs
H
Mhs
Mh
H
Mh
LS
LS
LS
LS
H
Mh
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
LSLS
LS
LS
ST HELEN'S WOOD
ST HELEN'S WOOD
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
30.1
28.0
34.5
26.2
32.4
BM 2
7.53
GREYGATESGREYGATES
P2P1
P5P6
P3
P438
.0m
0.0m
38.0
m
54.8m
38.0
m0.0m
38.0
m
54.8m
38.0
m
54.8m
38.0
m
54.8m
Soccer100.0m x 64.0m
38.0
m
0.0m
38.0
m
54.8m
38.0
m0.0m
38.0
m
54.8m
38.0
m
54.8m
38.0
m
54.8m
SCALE 1 : 1000
0 20m 40m
Pole loca on(s) dimensions are rela veto 0,0 reference point(s)
Colaiste Eoin SchoolBlackrock,LEINSTER
EQUIPMENT LAYOUTINCLUDES:· GAA Pitch· Soccer
Electrical System Requirements: Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing.
Installa on Requirements: Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design loca ons.
EQUIPMENT LIST FOR AREAS SHOWNPole Luminaires
QTY LOCATION SIZE GRADEELEVATION
MOUNTINGHEIGHT
LUMINAIRETYPE
QTY /POLE
4 P1, P3-P4P6
18m - 18m TLC-LED-1150 7
2 P2, P5 18m - 18m TLC-LED-1150 66 TOTALS 40
SINGLE LUMINAIRE AMPERAGE DRAW CHARTBallast Speci ca ons
(.90 min power factor)Line Amperage Per Luminaire
(max draw)
Single Phase Voltage 208(60)
220(60)
240(60)
277(60)
347(60)
380(60)
480(60)
TLC-LED-1150 6.8 6.5 5.9 5.1 4.1 3.7 3.0
190498
N.KEROLOS
N.Mcsherry
1:100
3/15/18
1 1
NK
Gal
vani
zed
stee
l pol
e
Prec
ast c
oncr
ete
base
Mus
co
Li
ght-S
truct
ure
Syst
empo
leTL
C fo
r LED
lum
inai
res
60FT
POLE
(S):
P1,
P3,
P4,
P6
Gro
und
leve
l
Pole
top
lum
inai
reas
sem
bly
Elec
trica
l com
pone
nts
encl
osur
e
190498
N.KEROLOS
N.Mcsherry
1:100
3/15/18
1 1
NK
Gal
vani
zed
stee
l pol
e
Prec
ast c
oncr
ete
base
Mus
co
Li
ght-S
truct
ure
Syst
empo
leTL
C fo
r LED
lum
inai
res
60FTPO
LE(S
): P
2, P
5
Gro
und
leve
l
Pole
top
lum
inai
reas
sem
bly
Elec
trica
l com
pone
nts
encl
osur
e