PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements : Expected total rate for 9.25 < R < 120 cm: 12.1 MHz: - 3.9 MHz from decays before GTK3 - 5.7 MHz from K + decay (see presentation by S. Gallorini, TDAQ meeting, 3 February 2010) Level 0 trigger rate must not exceed 1 MHz veto all triggers associated with muons crossing MUV-3 Random vetoing of good events must be kept as low as possible: MUV-3 time resolution must be as good as possible (random veto probability at 12.1 MHz = 1.2 % for 1 ns) I. Mannelli, C. Biino, L. DiLella, N. Doble, R. Fantechi, F. Marchetto, V. Obraztsov HAC-MUV Working Group 23 March 2010

Upload: nathaniel-austin

Post on 20-Jan-2018

212 views

Category:

Documents


0 download

DESCRIPTION

Original sketches by Italo Mannelli Only direct light is collected by the PMT (all scintillator faces but one, and all walls, are blackened)

TRANSCRIPT

Page 1: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

PROPOSAL FOR A MUON VETO SYSTEMBEHIND THE HADRONIC CALORIMETER

(MUV-3)

Problems and requirements: Expected total rate for 9.25 < R < 120 cm: 12.1 MHz: - 3.9 MHz from decays before GTK3 - 5.7 MHz from K+ decay (see presentation by S. Gallorini, TDAQ meeting, 3 February 2010) Level 0 trigger rate must not exceed 1 MHz veto all triggers associated with muons crossing MUV-3 Random vetoing of good events must be kept as low as possible: MUV-3 time resolution must be as good as possible (random veto probability at 12.1 MHz = 1.2 % for 1 ns) 1 ns time resolution excludes light collection and readout using wave-length shifting fibers

I. Mannelli, C. Biino, L. DiLella, N. Doble,R. Fantechi, F. Marchetto, V. Obraztsov

HAC-MUV Working Group 23 March 2010

Page 2: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

Proposal (Italo Mannelli):Counters consisting of a 2.5 cm thick scintillator plate facing a 2” PMTAir light guideScintillator plate dimensions 15.8 x 15.8 cm2

Distance between scintillator and PMT window 16 cmOnly direct light is collected by the PMT

Reuse as much as possible NA48 AKL hardware: PMTs with housing and magnetic shielding Constant Fraction Discriminators High Voltage Power Supplies and (possibly) associated slow control Cables (?) Scintillator (suitably reshaped and reassembled)

Page 3: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

Original sketches by Italo Mannelli

Only direct light is collected by the PMT(all scintillator faces but one, and all walls, are blackened)

Page 4: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

Results from a simple Monte Carlo simulation of scintillation light Scintillator tile dimensions 158 x 158 x 25 mm Distance between scintillator exit face and PMT cathode 160 mm PMT quantum efficiency 10% Expect ~170 photoelectrons (p.e.) for normal incidence in tile center; ~110 photoelectrons (p.e.) for normal incidence near tile corner.

Page 5: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

MUV-3 counters are assembled into mechanical units (“boxes”),each consisting of 4 x 4 counters → 16 boxes in total For each of the four boxes near the beam pipe one counter has aSpecial shape to accommodate the beam pipe

Page 6: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

Progress in mechanical design

Box with 4 x 4 counter matrixWall of 4 x 4 boxes → 256 counters

(from A. Bianucci, INFN, Pisa)

Page 7: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

Reusing the NA48 AKL PMTs

Thin blackplastic cylinder -metal

Black plastic cylinder and -metal must be cut here for good light collection (no shadowing)but then the magnetic shielding may become too weak, especially for the PMTsnear the beam pipe, close to the magnet bending the beam out of the SAC Should all counter walls be lined with -metal plates?

MUV-3 total thickness along beam 483 mm, including 50 mm for connectors and cables

Page 8: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

A counter based on the proposed design was built ~30 years agousing NE102A scintillator and a 2” XP 2232B PMTB. Asman et al., NIM 187 (1981) 371

60 photoelectrons were measured for normal incidence in center,dropping to ~52 for incidence near corner (compatible with the predictionfor the proposed counter, given the different scintillator – PMT distance)Width of the timing distribution constant across the box, giving aninherent time resolution of 0.5 ns (rms) (with 70 m RG 213/U cable)Max. time shift from corner to centre 0.3 nsUse of 70m RG58/U cable worsens the time resolution by 15%

Page 9: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

Čerenkov effect in the PMT window For the counter described in the 1981 NIM article a 2.8 ns earlier signal was observed, originating from particles traversing the PMT Measured most probable signal amplitude: ~15 photoelectrons(with scintillator removed and particle traversing the PMT) The same effect is expected for the proposed MUV-3 counters, but theČerenkov signal should be earlier by only (16/38)x2.8 ns ≈ 1.2 nsTurning the counter by 180º, so that particles first traverse the PMT and then the scintillator does not help because Čerenkov light is totally reflected at the PMT window exit (this happens for normal incidence in all transparent media with refractive index n > √2 ≈ 1.41)

For borosilicate glass(PMT window ) n = 1.52 – 1.56

Discriminator threshold must be adjusted above signal levelfrom Čerenkov light in PMT window

Page 10: PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements: …

WORK TO DO TO VALIDATE THE PROPOSED MUV-3 SYSTEM

Build one or two prototypes and study their performance on test beams - Signal amplitude and time resolution as a function of the beam particle impact point - Effect of Čerenkov light from particles traversing the PMT - Optimization of the scintillator type and thickness - Effectiveness of magnetic shielding, especially for the stray field produced by the magnet bending the beam away from the SAX

Some tests are in preparation at IHEP (Protvino) using PMTs from the NA48 AKL

The proposed construction scheme can also be applied to Anti-0,a system of counters to be installed immediately after thelast collimator to veto produced by halo muons interacting nearthe end of the collimator