ABSTRACT
Multilevel dcdc converters making use of high frequency transformers are
suitable for integration in solid-state solutions for applications in electric power
distribution systems. This paper presents a simplified switching scheme for three-
level full-bridge dcdc converters that enables zero-voltage and zero current
switching of all the main power devices. It describes the main operational modes and
design equations of the converter as well as provides simulation and experimental
results to demonstrate the feasibility of the proposed ideas.
The technique of zero voltage switching in modern power conversion is
explored. Several ZVS topologies and applications, limitations of the ZVS technique,
and a generalized design procedure are featured. Two design examples are presented:
a 50 Watt DC/DC converter, and an off-line 300 Watt multiple output power supply.
This topic concludes with a performance comparison of ZVS converters to their
square wave counterparts, and a summary of typical applications.
-
8/2/2019 Project Report 3l Fb Converter
2/43
TABLE OF CONTENTS
1. INTRODUCTION
2. OVERVIEW OF ZVZCS
2.1 ZERO VOLTAGE SWITCHING OVERVIEW
2.2 ZERO VOLTAGE SWITCHING VS CONVENTIONAL SQUARE
WAVE
3. PROPOSED ZVZCS CONVERTER
3.1 POWER DIAGRAM
4. CONTROL CIRCUIT FOR PROPOSED SYSTEM
5. DRIVER CIRCUIT FOR THE PROPOSED SYSTEM
6. THEORITICAL BACKGROUND OF THE PROPOSED SYSTEM
6.1 CONVERTER OPERATIONAL MODES
6.2 DESIGN EQUATIONS
6.3 CONVERTER LOSSES
6.4 SOFT SWITCHING RANGE
7. EXPERIMENTAL RESULTS
-
8/2/2019 Project Report 3l Fb Converter
3/43
8. ZVS DESIGN EQUATIONS AND ZVS DIFFERENCES
9. ZVS BENFITS
10. APPLICATIONS
CONCLUSION
LIST OF FIGURES
REFERENCES
1. INTRODUCTION
Advances in resonant and quasi-resonant power conversion technology
propose alternative solutions to a conflicting set of square wave conversion design
goals; obtaining high efficiency operation at a high switching frequency from a high
voltage source. Currently, the conventional approaches are by far, still in the
production mainstream. However, an increasing challenge can be witnessed by the
emerging resonant technologies, primarily due to their lossless switching merits. The
intent of this presentation is to unravel the details of zero voltage switching via a
comprehensive analysis of the timing intervals and relevant voltage and current
waveforms.
The concept of quasi-resonant, lossless switching is not new, mostnoticeably patented by one individual and publicized by another at various power
conferences Numerous efforts focusing on zero current switching ensured first
perceived as the likely candidate for tomorrows generation of high frequency power
converters . In theory, the on, off transitions occur at a time in the resonant cycle
-
8/2/2019 Project Report 3l Fb Converter
4/43
where the switch current is zero, facilitating zero current, hence zero power
switching. And while true, two obvious concerns can impede the quest for high
efficiency operation with high voltage inputs. By nature of the resonant tank and zero
current switching limitation, the peak switch current is significantly higher than its
square wave counterpart.
In fact, the peak of the full load switch current is a minimum of twice that of
its square wave kin. In its off state, the switch returns to a blocking a high voltage
every cycle. When activated by the next drive pulse the MOSFET output capacitance
(Goss) is discharged by the FET, contributing a significant power loss at high
frequencies and high voltages. Instead, both of these losses are avoided by
implementing a zero voltage switching technique.
High-voltage high-power isolated dcdc converters have several potential uses
in the electric utility industry, such as interfaces for high-power distributed
generation, renewable resources, energy storage, dc interlinks, and solid state power
substations . Traditionally, switching devices with high-voltage blocking capability,
such as thyristors and gate turn-off thyristors (GTOs) are used since they are more
compatible with voltage levels seen in utility applications. The main disadvantage of
these devices is that they switch very slowly, and in the case of thyristors, an external
circuit is required for turn-OFF. Faster switching devices such as MOSFETs and (low
voltage) insulated-gate bipolar transistors (IGBTs) bring many advantages in terms of
system size and dynamic response but are unable to withstand large voltages. In order
to take advantage of these smaller faster devices, several multilevel topologies have
been proposed in order to reduce the voltage seen by individual switching devices.
-
8/2/2019 Project Report 3l Fb Converter
5/43
The main multilevel topologies diode clamped, flying capacitor, and cascade
provide for reliable division of voltage across the switching devices. High
efficiency is required for any high-voltage solid-state solution intended to replace
fundamental-frequency transformers in utility applications since existing transformer
technology can be as high as 99% efficient. Peak losses in switching converters occur
during the switching instants, and these losses increase with increasing switching
frequency. Many soft-switching topologies have been proposed to reduce these
switching losses, with quasi-resonant phase-shifted zero-voltage switching (ZVS) and
zero-voltage zero-current switching (ZVZCS) drawing particular interest since they
do not cause added current or voltage stresses to the converter components. Of the
two, ZVZCS is preferred due to the reduction of the circulating current and the wide-
load operation ability. Over time, researchers combined these soft-switching
topologies with multilevel topologies to provide superior performance at high
voltage.
Diode-clamped multilevel converters are of interest since they have fewer
capacitors than flying-capacitor converters and do not require multiple independent
voltage sources as do cascade multilevel converter. ZVS and ZVZCS three-level
(3L) half bridge (HB) converters have been proposed, but these converters face the
disadvantage that they only apply half the dc-bus voltage to the primary of the
transformer. Greater power transfer can be achieved with a full-bridge (FB) topology,
but it is a challenge to establish a proper switching scheme to achieve soft-switching
operation for all the main power devices. So far, this has been accomplished for ZVS
3L FBs and for ZVZCS three-phase 3L converters.
This paper presents a simple control strategy that reduces control complexity,
device voltage stresses and achieves soft switching for all main power devices for the
-
8/2/2019 Project Report 3l Fb Converter
6/43
3L FB ZVZCS converter topology. In addition, this converter has reduced circulating
currents, wider load operation compared to the ZVS 3L FB, and the control can be
implemented with existing phase shifted pulse width-modulated (PWM) controllers.
-
8/2/2019 Project Report 3l Fb Converter
7/43
2. OVERVIEW OF ZVZCS
2.1 ZERO VOLTAGE SWITCHING OVERVIEW
Zero voltage switching can best be defined as conventional square wave powerconversion during the switchs on-time with resonant switching transitions. For the
most part, it can be considered as square wave power utilizing a constant off-time
control which varies the conversion frequency, or on-time to maintain regulation of
the output voltage. For a given unit of time, this method is similar to fixed frequency
conversion which uses an adjustable duty cycle. Regulation of the output voltage is
accomplished by adjusting the effective duty cycle, performed by varying the
conversion frequency. This changes the effective on-time in a ZVS design. The
foundation of this conversion is simply the volt-second product equating of the input
and output. It is virtually identical to that of square wave power conversion, and
vastly.
-
8/2/2019 Project Report 3l Fb Converter
8/43
2.2 ZERO VOLTAGE SWITCHING VS CONVENTIONAL
SQUARE WAVE
Unlike the energy transfer system of its electrical dual, the zero current
switched converter. During the ZVS switch off-time, the L-C tank circuit resonates.
This traverses the voltage across the switch from zero to its peak, and back down
again to zero. At this point the switch can be reactivated, and lossless zero voltage
switching facilitated. Since the output capacitance of the MOSFET switch (Co& has
been discharged by the resonant tank, it does not contribute to power loss or
dissipation in the switch. Therefore, the MOSFET transition losses go to zero -
regardless of operating frequency and input voltage. This could represent a
significant savings in power, and result in a substantial improvement in efficiency.
Obviously, this attribute makes zero voltage switching a suitable candidate forhigh frequency, high voltage converter designs. Additionally, the gate drive
requirements are somewhat reduced in a ZVS design due to the lack of the gate to
drain (Miller) charge, which is deleted when V& equals zero. The technique of zero
voltage switching is applicable to all switching topologies; the buck regulator and its
derivatives (forward, half and full bridge), the fly back, and boost converters, to
name a few. This presentation will focus on the continuous output current, buck
derived topologies.
3. PROPOSED ZVZCS CONVERTER
-
8/2/2019 Project Report 3l Fb Converter
9/43
The goal of the design is to produce a dcdc converter that achieves soft
switching for all the main switches, reduces the voltage stresses across each main
switch, and controls the voltage on the secondary as per an FB step-down converter is
the circuit topology and the operational waveforms of the proposed converter. The
resistance Rload is the load equivalent resistance and might represent, for example,
the inverter interfacing a distribution system. The intermediate voltage stages
typically available in a 3L converter (i.e., }Vdc/2) allow a better approximation of a
sinusoid thus resulting in a reduction in harmonic levels for the inverter case, but this
feature is not applicable to the dcdc converter in this paper since the output voltage
Vout , fixed at a constant dc level, is greater than the intermediate levels typical ofdcac 3L converters. If the intermediate voltages were used, the voltage at the input
of the diode-bridge rectifier would be less than Vout and the rectifier would not
conduct, so no power would be delivered to the load. Table I gives the proposed
switching states and identifies the voltage levels VSat the output of the transformer
for each switching state. A + symbol indicates that the switch is ON during the
switching state, while a symbol indicates that the switch is OFF.
The switching frequency is fixed and each switch is ON for exactly half a
switching cycle, but the timing of the turn-ON and turn-OFF of each switch is
controlled so that the dc-bus voltage is applied to the transformer for the desired time
as with phase-shifted PWM [9][11]. Using Table I and recognizing that the rectifier
causes the voltage at the output filter to be positive regardless of the polarity of the
transformer voltage, the reader can realize that the system has the same general
operating modes as a buck converter and will have the same differential equations.
The switching scheme, though it does not allow the intermediate voltage levels, does
achieve soft switching for all the main devices, as will be shown in Section III.
-
8/2/2019 Project Report 3l Fb Converter
10/43
Furthermore, the loss of intermediate switching states is consistent with other 3L
soft-switched designs.
As previously discussed, the rectifier diodes Drec1Drec4 Change the
transformer voltage so that a positive voltage is applied to the output filter regardless
of the polarity of the transformer voltage; thus, the converters operation can be
defined in terms of half cycles with the voltage and current seen by the output filter
LfCobeing the same for each half cycle. If the converter is in state 1 for durationD
Tsw/2, where D represents the duty cycle and is a fraction between 0 and 1, then
the average voltage at the rectifier will be
Vout =D Vdc (1)
n
where n is the turns ratio of the transformer. This provides the desired dc voltage
conversion and shows that the system operates as a transformerized buck converter.
Section III will show how the switching scheme achieves soft switching. Examining
Table I and Fig. 1(a) reveals that diagonal switches receive the same control signals.
The switching scheme can be simplified by controlling the devices in pairs, so that
each pair S1 and S8, S2 and S7, S3 and S6 , and S4 and S5receives the same
control signal. It can be further noted that the switching order and duration is
identical to phase-shifted PWMfor a twolevel FB [11], so existing phase-shifted
PWMcontrollers can be used to control the converter.
This is an advantage compared to other 3L FB soft-switching topologies
which require complex switching control schemes, such as double-phase-shifted
control. The proposed 3L FB converter operates at twice the power of the standard
-
8/2/2019 Project Report 3l Fb Converter
11/43
two-level (2L) FB or 3L HB topologies in, since the 2L FB is limited to half the dc-
bus voltage for the same switch ratings while the 3L HB only applies half the dc-bus
voltage to the transformer. The 3L FB has the advantage of being able to handle the
same dc-bus voltage as the 3L HB, while applying the full dc-bus voltage to the
transformer like the 2L FB. The proposed converter has an advantage over hybrid
multilevel topologies in that it applies the full dc-bus voltage to the load for the entire
operating range. The proposed converter has an advantage over ZVS-only 3L FB
converters because ZVZCS converters have a wider soft-switching range than ZVS
converters.
Altogether, the proposed converter offers a high-voltage high-power solution
that gives soft switching to all the main switches, reduces the voltage stress applied to
the main switches thus allowing the use of devices with faster switching speeds, and
reduces the complexity of the switching controller so that existing technology can be
used for the switching controller.
-
8/2/2019 Project Report 3l Fb Converter
12/43
3.1 POWER DIAGRAM
-
8/2/2019 Project Report 3l Fb Converter
13/43
POWER DIAGRAM
1 3
2 5
T 1
D 1
D 2
D 3
D 4
C 1
C 2
C 3
D 1 4
D 5
D 6
FR306 X 10Nos
D 7
D 8
D 9
D 1 0
C 4
100:3
1 0 K H
10nF
D 1 1
D 1 2
C 5
C 6
C 7
10nFS1
S2
S3
S4
S5
S6
S7
S8
230/100 V
5000 M fd /
200 V
IR4PC30WD X 8Nos
Q 1
C 8
Q 2
L 1
Q 3
Q 4 Q 8
Q 7
1 5
4 8
T 2
Q 6
Q 5
D 1 3
-
8/2/2019 Project Report 3l Fb Converter
14/43
4. CONTROL CIRCUIT FOR PROPOSED SYSTEM
-
8/2/2019 Project Report 3l Fb Converter
15/43
O U T3
4
R S T
8
V C C
1
G N DCV
5
T R G2
T H R6
D S C H G7
U 1
N E 5 5 5
R 1
R 2
V R 1
C 1
C 2
D 1
D 0
3
D 14
D 26
D
4
1
3
D 51 4
C L K9
C L R1
Q 02
Q 15
Q 27
Q 31 0
Q 41 2
Q
5
1
5
1
6
V D D
8
G N D
U 2
C D 4 0 1 7
+ 1 2 V
+ 1 2 V
D5
C L K
3
Q
1
Q2
1
4
V D D
S6
7
G N D
R4
U 3 A
4 0 1 3
1
2
3
1
4
7
5
6
4
1
4
7
1 2
1
4
7
U 5 A
C D 4 0 6 9
D 0
3
D 14
D 26
1
3
D 4
D 51 4
C L K9
C L R1
Q 02
Q 15
Q 27
Q 31 0
Q 41 2
1
5
Q 5
1
6
V D D
8
G N D
U 6
C D 4 0 1 7
D9
C L K
1 1
Q
1 3
Q1 2
1
4
V D D
S8
7
G N D
R1 0
U 3 B
4 0 1 3
8
91
1
4
7
1 2
1 3
1
1
4
7
3 4
1
4
7
U 5 B
C D 4 0 6 9
+ 1 2 V
+ 1 2 V+ 1 2 V
+ 1 2 V
-
8/2/2019 Project Report 3l Fb Converter
16/43
5. DRIVER CIRCUIT FOR THE PROPOSED CIRCUIT
OPTO -COUPLER CIRCUIT
3 3 0 o h m
M C T 2 E
1 K 2 . 2 K
1 0 K
1 0 K
1 0 0 o h m
1 0 0 0 m F
1 2 v A C1 2 v D C
G A T E
1
2 4
5
1 0 0 o h m
1 0 0 o h m
3 3 0 o h m
M C T 2 E
1 K 2 . 2 K
1 0 K
1 0 K
1 0 0 o h m
1 0 0 0 m F
1 2 v A C1 2 v D C
G A T E
1
24
5
1 0 0 o h m
1 0 0 o h m
3 3 0 o h m
M C T 2 E
1 K 2 . 2 K
1 0 K
1 0 K
1 0 0 o h m
1 0 0 0 m F
1 2 v A C1 2 v D C
G A T E
1
2 4
5
1 0 0 o h m
1 0 0 o h m
3 3 0 o h m
M C T 2 E
1 K 2 . 2 K
1 0 K
1 0 K
1 0 0 o h m
1 0 0 0 m F
1 2 v A C1 2 v D C
G A T E
1
2 4
5
1 0 0 o h m
1 0 0 o h m
3 3 0 o h m
M C T 2 E
1 K 2 . 2 K
1 0 K
1 0 K
1 0 0 o h m
1 0 0 0 m F
1 2 v A C1 2 v D C
G A T E
1
2 4
5
1 0 0 o h m
1 0 0 o h m
3 3 0 o h m
M C T 2 E
1 K 2 . 2 K
1 0 K
1 0 K
1 0 0 o h m
1 0 0 0 m F
1 2 v A C1 2 v D C
G A T E
1
2 4
5
1 0 0 o h m
1 0 0 o h m
-
8/2/2019 Project Report 3l Fb Converter
17/43
6. THEORETICAL BACKROUND OF THE PROPOSED SYSTEM
6.1.CONVERTER OPERATIONAL MODES
The following analysis assumes that the switching devices are ideal, the output
filter is large enough to act as a constant current source for the entire period, and the
blocking capacitor is large enough to act as a constant voltage source while the
current is being reset.
1) Operational Mode 1: t0 t < t1 :
Switches S1 and S8 have been ON for a (relatively) long time and Cb0 is charged
to Vcb0p.At t = 0, switches S2 and S7 begin conducting and (Vdc Vcb0p ) is
applied to the primary of the transformer. As a result, the primary current rapidly
rises from 0 to the reflected output current
Ip0 = Io/n ..(1)
where Ip0 is the peak value of the primary side current going into the transformer, Io
is the current through Lf , and n is the turns ratio of the transformer. The voltage
applied to the transformer leakage inductor Llk during this period is
Vdc (VCb0) = Vdc + VCb0 , .(2)
and the duration of this period is
t1 0 = t1 = Llk Ip0/(Vdc + VCb0) ... (3)
-
8/2/2019 Project Report 3l Fb Converter
18/43
Since this period is so short, vcb0 is assumed to be constant throughout the period.
The load current is not completely supplied by Vdc during this period, so the excess
current freewheels through the secondary rectifier diodes Drec1Drec4
.
2) Operational Mode 2: t1 t < t2 :
The freewheeling mode ends when the primary current reaches Ip0 at t1 and
diodes Drec3 and Drec4 stop conducting. The output filter is connected in series with
the leakage inductance of the transformer through Drec1 andDrec2 , and acts to keep
the primary current constant at Ip0 . Power is transferred from Vdc to the load during
this mode. The duration of this mode is related to the voltage conversion ratio by the
duty cycle parameter D, which is given by
-
8/2/2019 Project Report 3l Fb Converter
19/43
V0 / Vdc= D/n=(tON)/(Tsw /2)/n =(t2 t1 )/(Tsw /2)/n ... (4)
Since interval t1 is so short, tON is set equal to t2 and
D = t2/Tsw /2 . . (5)
The blocking capacitor is charged from Vcb0p to +Vcb0p by
Ip0 during this mode.
-
8/2/2019 Project Report 3l Fb Converter
20/43
3) Operational Mode 3: t2 t < t3 :
Switches S1 and S8 are turned OFF at t2 . Capacitors C1 and C8 are charged
and C4 and C5 are discharged by ip , which is still held constant at Ip0 by the large
output filter inductance. When C4 and C5 are completely discharged at t3 , the
primary current begins to circulate through devices S2 and S7 and diodes Dc1 and
Dc4 . Switches S4 and S5 can be gated ON under complete ZVS at any time after t3 .
Since this mode is so short, vcb0 is assumed to remain constant at Vcb0p for the
duration of this mode. Each of the parallel capacitors conducts Ip0/2 during this mode
and has a change of voltage of Vdc/2. Using the same value Cr for capacitors C1, C4,
C5 , and C8 , the duration of this mode is
t3 t2 = Cr Vdc/Ip0 ... (6)
-
8/2/2019 Project Report 3l Fb Converter
21/43
4) Operational Mode 4: t3 t < t4 :
As the primary current circulates through S2, S7,Dc1 , and Dc4 , theblocking capacitor voltage Vcb0p is applied to the transformer and the primary
current begins to decrease. As soon as the primary current falls below Ip0 , the
output current begins to freewheel through the output rectifier diodes,
disconnecting the primary side of the circuit from the load and short circuiting
the transformer magnetizing inductance. Thus, the reset time is dependent on
theleakage inductance
T reset = t4 t3 = Llk Ip0/Vcb0p ... (7)
-
8/2/2019 Project Report 3l Fb Converter
22/43
-
8/2/2019 Project Report 3l Fb Converter
23/43
FIG .2.
-
8/2/2019 Project Report 3l Fb Converter
24/43
6.2. DESIGN EQUATIONS
The design of the converter involves determining values for Cdc1, Cdc2, Css1,
Css2, C1, C4, C5, C8, Cb0, Llk , and the output filter. The output filter should be
large enough to maintain the load current for the entire switching period Tsw , while
the transformer leakage inductance Llk should be minimized in order to minimize the
reset time. Beyond these restrictions, transformer and filter design principles also
apply. Capacitors Cdc1 and Cdc2 are essential for the proper voltage division across
the switching devices .Consequently, they should be selected with identical values
using tight tolerance parts. In practice, the dc-bus capacitors will be required to
maintain the voltage through changes in the input voltage Vdc and through voltage
spikes caused by parasitic inductances, so a large value may be required. Smaller
-
8/2/2019 Project Report 3l Fb Converter
25/43
capacitors with good high-frequency response may be placed in parallel with the
bulk dc-bus capacitors in order to handle high-frequency ripple due to parasitic
components. Capacitors Css1 and Css2 are also identical. Fig. 2 shows that they
conduct during mode 3 and its mirror, mode 8. These capacitors must maintain a
near-constant voltage during the entire cycle; thus, they should be selected so that
they do not experience more than a 5%voltage change during mode 3. Each capacitor
conducts Ip0/2 during mode 3, and its nominal voltage is Vdc/2. Therefore, the
capacitor value required for a 5%ripple is
Css= Ip0 (t3 t2 )/0.05 Vdc ..(8)
This can be simplified using (6), so that
Css= Cr/0.05 = 20 Cr (9)
The size of the parallel capacitors, Cr , is determined by the minimum
requirement to achieve ZVS during turn-OFF, which requires that the parallel
capacitors must be large enough to hold the voltage close to zero during the current
falltime of the device tf i, which can be determined from the data sheet . Once this
parameter has been determined, Cr can be calculated as follows:
Cr = tf i Ip0/Vdc ..(10)
A large value of Vcb0p is desirable in order to quickly reset the primary
current during mode 4, but the OFF devices; see (Vdc + Vcb0p )/2 at the end of
mode 2. Thus, the value of Vcb0p should be limited to one-fifth the dc-bus voltage in
order to limit the voltage stress on the devices. Capacitor Cb0 is charged from
-
8/2/2019 Project Report 3l Fb Converter
26/43
Vcb0p to +Vcb0p during mode 2 by ip at a value of Ip0 . The blocking capacitor
will reach its largest value when the converter is transferring maximum rated power
and ip is at Ip0,max. In order to meet the voltage restriction outlined earlier for these
conditions, Cb0 should be chosen as
Cb0=5Ip0.max Dmax/4 fsw Vdc (11)
where Ip0,max is themaximum value of the steady-state primary current expected
during normal operation, Dmax is the value of the duty cycle at maximum power
transfer, and fsw is the switching frequency.
Since Vcb0p is directly proportional to Ip0 , any value of ip less than Ip0,max
will result in a value of Vcb0p less than Vdc/5. The voltage Vcb0p for any value of
Ip0 less than Ip0,max or any D less than Dmax is
Vcb0p=Ip0D/4 fsw Cb0 (12)
6.3 CONVERTER LOSSES
The losses in the FB can be divided into two components:
switching and conduction losses. Switching losses of the lagging leg switches
the inner four switches S2, S3, S6 , and S7are negligible since they switch under
ZCS; likewise, the switching losses of the leading switchesthe outer four switches
S1, S4, S5 , and S8during turn-ON are negligible since the voltage across the
devices is reduced to zero before switching. The losses in the leading devices during
turn-OFF, however, are dependent on the size of the parallel capacitor. As the current
-
8/2/2019 Project Report 3l Fb Converter
27/43
through the devices falls to zero, the difference between the device current and the
primary current flows through the parallel capacitor causes a rise in voltage, and thus,
the switch has a small amount of switching loss. The energy lost in each ZVS turn-
OFF event is given by
Ezvs,OFF=I2p0t2fi/48 Cr ..(13)
Switches S1, S4, S5 , and S8 each undergo ZVS turn-OFF once per switching
cycle, so the ZVS turn-OFF losses are
Pzvs,OFF=4Ezvs,OFF fsw .(14)
Since mode 1 is so short, it is lumped together with mode 2 to determine the
conduction losseswhile power is being transferred to the load. During this period, S1,
S2,D2,D7, S7, S8 , and Cb0 are conducting the primary current Ip0 . The conduction
losses for these devices during this time are
P1,2=[(2Von,diode + 4 Von,IGBT) Ip0 + RESR,C b0 I p02] D/2 .(15)
Mode 3 is the ZVS transition, so the losses in S1, S4, S5 , and S8 during this
mode are represented by (13) and (14). Components S2,D2,D7, S7 , and Cb0 are still
conducting during this mode, however, and sustain losses of
P3 = [(2 VON,diode + 2 VON,IGBT) Ip0 + RESR,C b0 Ipo X Ipo] Cr
fsw Vdc//Ip0 .... (16)
-
8/2/2019 Project Report 3l Fb Converter
28/43
During mode 4, S2,D2,D7, S7, Cb0,Dc1 , and Dc4 are all conducting while the
current is reset. The losses during this mode are
P4 =[(4 VON,diode + 2 VON,IGBT) Ip0/2+ RESR,C b0x I p0/3]2_ f2sw
Llk Cb0/D .. (17)
There are no conduction losses during mode 5 since the current through the FB
is zero. The conduction losses in modes 6 and 7 are identical to those in modes 1 and
2 and are given by (15). Similarly, the conduction losses in modes 8 and 9 are given
by (16) and (17), respectively. Mode 10, like mode 5, has no conduction loss. The
total losses for the ZVZCS FB are
PT = Pzvs,OFF + 2 (P1,2 + P3 + P4 ) .... (18)
6.4 SOFT-SWITCHING RANGE
ZVS is accomplished when Ip0 discharges the parallel capacitors across the
leading switches during mode 3. The length of mode 3, referred to as the dead time,
limits the maximum duty cycle that can be commanded by the controller, which, in
turn, limits the maximum voltage that can be achieved on the secondary and the
maximum power that can be delivered to the load. Since ZVS, and hence the dead
time, occurs twice per half cycle, the maximum duty cycle is
Dmax=12tdead/Tsw/2. .(19)
-
8/2/2019 Project Report 3l Fb Converter
29/43
Once the dead time is fixed, there is a minimum value of the load current under
which ZVS no longer occurs since the leading switches will be switched before the
parallel capacitors are completely discharged. This minimum load current is given by
Ip0,min=CrVdc/tdead .. (20)
The dead time must not only be selected to maximize the load current range for
which ZVS occurs but must also minimize the reduction of the duty cycle. The
precise value of the dead time will vary depending on the needs of the application,
i.e., whether the application will require high duty cycles or whether it will require a
large soft-switching range. ZCS is accomplished when the blocking capacitor voltage
drives the primary current to zero before the state change that occurs at Tsw /2. The
current begins to be reset at t2 = D Tsw /2,
so the total time available to reset the current is
Treset,max=(1D)Tsw/2 ..(21)
ZCS will be achieved if the reset period from (6) is less than Treset,max, and
using the value for Vcb0p from (12),
4fsw b0 Llk/D (1 D) Tsw/2 ..(22)
It can be seen from this equation that achieving ZCS is independent of the load
current, though the voltage across Cb0 may become very large if the primary current
exceeds the maximum load current used in (10) to calculate the value of the blocking
capacitor. There is a limit on the range of duty cycles for which ZCS occurs.
-
8/2/2019 Project Report 3l Fb Converter
30/43
7. EXPERIMENTAL RESULTS
To demonstrate the proposed converter, a 100 V:30V, 100-W 10-kHz scaled
down prototype was designed. IRG4PC30KD IGBTs were used for the switching
devices S1S8 , with HFA25TB60 HEXFRED diodes as the antiparallel and series
diodes D1D8 . In the prototype, Cree CSD10060 A silicon carbide and IR 10ETF06
silicon schottky diodes in parallel were used for the rectifier. The capacitors utilized
for the dc-bus,Cdc, were 2.2 F electrolytics, the clamping capacitors, Css, were 1 F
polypropylene, and the parallel capacitors C1, C4, C5 , and C8 were 4.7 nF ceramic.
The output filter inductance and capacitance were selected to be large in order
to emulate an ideal current source, as per the assumptions given in the derivations in
Section III. The output filter inductor was 1.7 mH and the output filter capacitor was
710 F. The PSpice simulation operational waveforms are shown in Fig.3
-
8/2/2019 Project Report 3l Fb Converter
31/43
The simulated waveforms are nearly the same as the theoretical waveforms
except for a slight slope in the steadystate primary current caused by the current
ripple in the output filter inductor. There was ringing in the primary current after
resetting that was also seen in VPrimary for the same time period, which was due to
the LC interaction of the leakage inductance with the capacitance of the series diodes
D2,D3,D6 , and D7 .
The ZVS of S1 during turn-OFF is shown in Fig. 4(a), where it was noticed
that the voltage stress across the switch was limited to Vdc/2 = 100 V. This was not
complete ZVS turn-OFF, since the voltage across the switch rises during turn-OFF,
-
8/2/2019 Project Report 3l Fb Converter
32/43
reaching 50 V before the device finishes turning OFF. This is consistent with the
analysis given in Section III-B. By contrast, S4 has complete zero-voltage turn-ON,
since the voltage is reduced to zero before the device is switched, as shown in Fig.
4(b). The ZCS of S2 is shown in Fig. 4(c), which shows that the current falls before
the device is switched.
-
8/2/2019 Project Report 3l Fb Converter
33/43
Fig. 4 - Zero Voltage Switched Buck Regulator
Figures shows a plot of the efficiency of the bridge as a function of the load
current. The efficiency dropped off significantly as the current increased. This drop is
expected since conduction losseswhich are proportional to currentare the
dominant losses in the soft-switching converter. The conduction losses are increased
due to the larger number of devices in series, but this can be mitigated by using
lower-rated devices with a lower ON-state voltage drop compared to what would be
needed for a 2L design. The efficiency of the bridge at full load (10 A) was 93%,
which was a 4.3% drop off from the light load (1 A) efficiency of 97.3%. The
experimental operational waveforms for both full load (10 A) and light load (1 A).
Large spikes were seen in both the primary current and the primary voltage at
the instant that the dc-bus was applied to the transformer. These spikes are caused by
-
8/2/2019 Project Report 3l Fb Converter
34/43
the rectifier diodes in two ways. First, the full source voltage Vdc is applied to the
leakage inductance during mode 1 since the rectifier shorts the secondary side of the
transformer while the load current is freewheeling through it. The two rectifier
diodes that are not involved in the current cycle (Drec3 and Drec4 for the positive
cycle) turn OFF when the current provided by the source is equal to the load current,
but this turn-OFF does not happen instantaneously.
The full source voltage Vdc is still applied to the leakage inductance while the
diodes turn OFF, which results in a current overshoot in addition to the diode reverse
recovery currents, which is the second contribution the rectifier diodes make to the
current overshoot. Once the diodes turn OFF, this current is forced to decrease to Ip0
by Lf, resulting in a voltage spike as the current through Llkchanges rapidly. The
current and voltage oscillate as this transient dies down oscillations are the result of
interactions between mainly the transformer leakage inductance and diode
capacitance [28]. The spikes can be reduced by using rectifier diodes with faster turn-
OFF times and smaller reverse recovery currents (like SiC Schottky diodes).
The voltage and current waveforms for the rectifier on a 2L ZVZCS converter
implemented in both Si and SiC. The top waveform shows the primary-side
transformer voltage, the second waveform shows the secondary side transformer
voltage, the third waveform shows the voltage across Drec4 , and the bottom
waveform shows the transformer current reflected to the secondary side. It can be
seen from comparing the two waveforms that using a SiC device, which has a smaller
reverse recovery current and a faster turn-OFF time, results in a smaller current
overshoot and a shorter delay between the rise of the primary side voltage and the
rise of the secondary side voltage. The slope in the primary voltage was due to the
blocking capacitor voltage, which was added to VAB. Since the blocking capacitor
-
8/2/2019 Project Report 3l Fb Converter
35/43
charges to a higher value at higher currents, the slope in the voltage is more evident
at higher loading conditions.
The slope in the current was due to the ripple of the output filter inductor, and
was approximately 1 A. This ripple was the same for large or small currents, but it
was not as evident in the full-load condition since the scaling of the current is higher.
The soft switching of the devices. Fig. 8 shows the zero-voltage turn-OFF of S8 at
both full and light loads. As was the case in the simulation data, the voltage across
the device reached half the final voltage by the time the device finished switching
OFF in the full-load case, which was used in (9) to select the parallel capacitances.
Since the current is smaller at lighter loads, the capacitor voltage was lower when the
device switches OFF, resulting in reduced turn-OFF losses.
The same phenomenon was noted in , where the voltage across S8 took
considerably longer to reach zero at light loads than at full load. This is consistent
with the limit belowwhich the ZVZCS converter will not achieve ZVS for the leading
switches, as given by (20). For this system with a Cr of 4.7 nF, the limit on Ip0 is
0.47 A. The converter is operating at Ip0 = 1 A for Fig. 8(a), but this is approaching
the ZVS soft-switching limit and some losses occur near the end of the dead time
since the capacitor still has a small charge when the device turns ON and the current
through it begins to rise for the next cycle. These losseswill increase as the load
current decreases and there is less primary current available to discharge the parallel
capacitances, as discussed in Section III-D.
The steady-state collectoremitter voltage is shown in this figure and is limited
to 100 V, or half the dc input voltage. T he ZCS turn-ON of S2 . The voltage rises
quickly at both light and heavy loads, but the current rises more quickly at heavy
loads. The rate at which the current falls was nearly the same for both the full- and
-
8/2/2019 Project Report 3l Fb Converter
36/43
light-load cases. The current at turn-ON rises very rapidly due to the large applied
voltage. Still, the current does not rise until the voltage across the switch is at zero in
both cases, so soft switching is still achieved even at heavy loads. The ZCS turn-OFF
ofS2 , and the current is at zero for a long time before S2 is turned OFF in both the
light- and heavy-load cases. This shows that the switch achieves soft switching at
turn-OFF.
The reset time was approximately 1.4s, consistent with what was seen in the
simulations. The blocking capacitor was charged to a smaller voltage at lighter loads,
and therefore, Ip did not have as high a di/dt as at full load. There was less current to
reset, however, so the total reset time remained approximately constant.
7. ZVS DESIGN EQUATIONS
A zero voltage switched Buck regulator will be used to develop the design
equations for the various voltages, currents and time intervals associated with each
of the conversion periods which occur during one complete switching cycle. The
circuit schematic, component references, and relevant polarities are shown in
Fig. 4.Typical design procedure guidelines andshortcuts will be employed during
the analysisfor the purpose of brevity. At the onset, all components will be treated as
though they were ideal which simplifies the generation of the basic equations and
relationships. As this section progresses, losses and non-ideal characteristics of the
components will be added to the formulas. The timing summary will expound upon
the equations for a precise analysis.
-
8/2/2019 Project Report 3l Fb Converter
37/43
8. ZVS DIFFERENCES
Variable frequency operation (in general)
Higher off-state voltages in single switch, unclamped topologies
Relatively new technology - users must climb the learning curve
Conversion frequency is inversely proportional to load current
A more sophisticated control circuit may be required
9.ZVS BENEFITS
Zero power Lossless switching transitions
Reduced EMI / RFI at transitions
No power loss due to discharging Goss
No higher peak currents, (ie. ZCS) same as square wave systems High
efficiency with high voltage inputs at any frequency.
Can incorporate parasitic circuit and componentL & C
-
8/2/2019 Project Report 3l Fb Converter
38/43
10. APPLICATIONS
Reduced gate drive requirements (no Miller effects)
Short circuit tolerant
In the electric utility industry,
Such as interfaces for high-power distributed generation,
Renewable resources,
Energy storage,
Dc interlinks,
And solid state power substation.
Reduced gate drive requirements
Short circuit tolerant
-
8/2/2019 Project Report 3l Fb Converter
39/43
FUTURE ENHANCEMENT
Future research would include designing a prototype to implement an
active clamp to reset the current thus eliminating the series diodes and
the losses associated with them.
This would have the added benefit of reducing the spikes from the
rectifier diodes
-
8/2/2019 Project Report 3l Fb Converter
40/43
CONCLUSION
This paper proposed a 3L ZVZCS converter with a simplified switching
scheme for use in solid-state solutions. The converter was shown to have the
advantages of soft switching and reduced voltage stresses across the devices,
allowing higher voltage operation. The operation of the 3L FB ZVZCS converter was
analyzed. Experimental results further demonstrated the feasibility of the proposed
ideas. Future research would include designing a prototype to implement an active
clamp to reset the current thus eliminating the series diodes and the losses associated
with them. This would have the added benefit of reducing the spikes from the
rectifier diodes when the dc voltage is applied during modes 1 and 6.
-
8/2/2019 Project Report 3l Fb Converter
41/43
LIST OF FIGURES
1.POWER DIAGRAM - 2.3
2.DRIVER CIRCUIT FOR PROPOSED CIRCUIT 2.4
3.CONVERTER OPERATIONAL MODES - 2.5.1
4.PSPICE OPERATIONAL WAVEFORMS -3.1
5.ZERO SWITCHED VOLTAGE REGULATOR 3.1
-
8/2/2019 Project Report 3l Fb Converter
42/43
REFERENCES
F. BLAABJERG, Z. CHEN, AND S. B. KJAER, POWER
ELECTRONICS AS EFFICIENT INTERFACE IN DISPERSED POWER
GENERATION SYSTEMS, IEEE TRANS. POWER ELECTRON., VOL.
19, NO. 5, PP. 11841194, SEP. 2004.
J. D. LEEPER AND J. T. BARICH, TECHNOLOGY FOR
DISTRIBUTED GENERATION IN A GLOBAL MARKET PLACE, IN
PROC. AMER. POWER CONF., 1998, VOL. 1
L. M. TOLBERT AND F. Z. PENG, MULTILEVEL CONVERTERS AS
A UTILITY INTERFACE FOR RENEWABLE ENERGY SYSTEMS, IN
PROC. 2000 POWER ENG. SOC. SUMMER MEETING, 2000, VOL. 2
F. ZHANG, F. Z. PENG, AND Z. QIAN, STUDY OF THE
MULTILEVEL CONVERTERS IN DCDC APPLICATIONS, IN PROC.
2004 IEEE ANNU. POWER ELECTRON. SPEC. CONF. (PESC 2004)
A. MEDURY, J. CARR, J. BALDA, H. MANTOOTH, AND T. FUNAKI,
THREE-LEVEL ZVZCS AND ZVS HALF-BRIDGE CONVERTERS: A
-
8/2/2019 Project Report 3l Fb Converter
43/43
COMPARATIVE EVALUATION, IN PROC. 4TH POWER CONVERS.
CONF., APR. 2007, PP. 892898.