project description structural design criteria … · conflict, request clarification from...
TRANSCRIPT
(15)#5Tx6'-0"@18"OC
(15)#5Tx6
'-0"@18"OC
(5)#5B
x6'-6"@12
"OC ADD
PLAN KEYS AND SYMBOLS
1S101
1S101
S1011
REFERENCEXXX' - YY"
ELEVATION VIEW1 = DRAFTING NUMBER
S101 = SHEET NUMBER
WALL / BUILDING SECTION1 = DRAFTING NUMBER
S101 = SHEET NUMBER
SECTION CUT1 = DRAFTING NUMBER
S101 = SHEET NUMBER
DETAIL CALL OUT1 = DRAFTING NUMBER
S101 = SHEET NUMBER
ADDENDUM NUMBER00
STEPS AND SLOPES IN DECKS & SLABSYY" = STEP HEIGHT
ELEVATION CALLOUTREFERENCE = T/OBJECT OR B/OBJECTXXX'-YY" = OBJECT ELEVATION
YY"
CX
BPX
xxK
M1
OP#
SPLICE IN BEAM/GIRDER
MOMENT CONNECTIONS THROUGH BEAM
MOMENT CONNECTIONS TO COLUMN
STEEL BEAM WITH CONCRETE EMBED PLATE, RE: TYPICAL DETAILS
STEEL BEAM WITH BEAM POCKET,RE: TYPICAL DETAILS
STEEL BEAM PENETRATION,RE: BEAM PENETRATION SCHEDULE
DIRECTION OF DECK SPAN ORDIRECTION OF REINFORCING
WOOD JOIST HANGERH1 = JOIST HANGER TYPE, RE: SCHEDULE
H1
JOIST TYPEJ1 = JOIST TYPE, RE: SCHEDULE
J1
KEYED NOTEK = KEYED NOTE, RE: SCHEDULE
K
GRADE BEAM TYPEGB1 = GRADE BEAM TYPE, RE: SCHEDULE
M1MASONRY WALL TYPE
M1= MASONRY WALL TYPE, RE: SCHEDULE
COLUMN TYPECX = COLUMN TYPE, RE: SCHEDULEBPX = BASE PLATE, RE: SCHEDULExxK = TRANSFER LOAD
GB1
DIRECTION OF DECK SPAND# = DECK TYPE, RE: SCHEDULE
D#
COLLECTOR BEAM CONNECTIONSC-1 = COLLECTOR CONNECTION,
RE: SCHEDULEXk = DESIGN AXIAL FORCE THROUGH
CONNECTION
SC-1Xk
1S101
FOUNDATIONS
DRILLED PIER NOTATIONPx = PIER TYPE RE: SCHEDULEXXk = COMPRESSION LOAD (K)YYk = TENSION LOAD (K)ZZk = SHEAR LOAD (K)XX'-XX" = TOP ELEVATIONYY'-YY" = BOTTOM ELEVATION(ZZ'-ZZ") = PIER CAP ELEVATION
XXk/YYk/ZZkPxYY'-YY"/XX'-XX"(ZZ'-ZZ")
S S FOOTING / FOUNDATION STEP
WALLS AND COLUMNS
CIP CONCRETE WALL ABOVE
MASONRY WALL ABOVE
WOOD FRAMED WALL ABOVE
COLD-FORMED STEEL WALL ABOVE
WALL BELOW (ALL MATERIALS)
WALL ABOVE W/ WINDOW *
WALL ABOVE W/ DOOR *
CIP CONCRETE COLUMN ABOVE
PRECAST CONCRETE COLUMN ABOVE
MASONRY COLUMN ABOVE
STEEL COLUMN ABOVE
WOOD COLUMN ABOVE
COLUMNS BELOW (ALL MATERIALS)
*CIP CONCRETE SHOWN; GRAPHICS APPLY TO OTHER WALL MATERIALS
WOOD SHEAR WALL PLAN KEY
SHEAR WALL ABOVE FLOOR/ROOF
SHEAR WALL BELOW FLOOR/ROOF
SHEAR WALL ABOVE & BELOW FLOOR/ROOF
WOOD SHEAR WALL DESIGNATION AND MINIMUM REQUIRED LENGTHRE: SHEAR WALL SCHEDULE
A 0"
HOLD DOWN FOR WOOD SHEAR WALLRE: HOLD DOWN SCHEDULE
HD#
WOOD FRAMING
BEAM / GIRDER
JOIST / RAFTER
PREMANUFACTURED FLOOR/ ROOF TRUSS
STEEL FRAMING
TRUSS
STEEL JOIST
SIZE(XX)c=Y" BEAM / GIRDER NOTATIONRL = REACTION LEFT (K)SIZE = MEMBER TYPE(XX) = # OF STUDSY" = CAMBER SIZERR = REACTION RIGHTXX'-YY" = T/STL ELEVATION
XX'-YY"RL RR
SECTIONS AND DETAILS
CIP CONCRETE
MASONRY
UNDISTURBED SOIL
SOIL FILL
MILDLY REINFORCED CONCRETE SLAB
UNIFORM REINFORCING NOTATIONS#6 = BAR SIZET= TOP OF SLAB POSITIONB = BOTTOM OF SLAB POSITION@18" = BAR SPACING
UNIFORM REINFORCING SHALLEXTEND THROUGHOUT EXTENTSOF SLAB, UNO
TOP COLUMN REINFORCING NOTATIONS(15) = QUANTITY OF BARS#5 = BAR SIZET = TOP OF SLAB POSITION6'-0" = LENGTH OF BARS@18"OC = BAR SPACINGS5 = STUDRAIL DESIGNATION
RE: STUDRAIL SCHEDULE ANDDETAIL
PLACE REINFORCEMENT GROUP CENTERED OVER COLUMN, OFFSET FROM COLUMN SHOWN FOR GRAPHICS ONLY
REINFORCING BAR WITH 90° HOOK
#6B@18"OC
#6T@18"OC
#6B
@18"OC
#6T@18"OC
OTHER ADDITIONAL REINFORCING NOTATIONS:
(5) = QUANTITY OF BARS#5 = BAR SIZET = TOP OF SLAB POSITIONB = BOTTOM OF SLAB POSITION6'-0" = LENGTH OF BARS@12" = BAR SPACING, WHEN
SPACING NOT SHOWN SPACE BARS EVENLY WITHIN EXTENTS
ADD = REINFORCING BARS REQUIREDIN ADDITION TO UNIFORM AND TOP COLUMN REINFORCING
UNO, DISTRIBUTE REINFORCING EQUALLY ON EACH SIDE OF COLUMN LINE AND CENTERED IN SPAN
SHOWS EXTENTS OF BAR DISTRIBUTION
REINFORCING BAR WITH 180° HOOK
HOOKS SHOWN WHERE APPLICABLE
HOOKS SHOWN WHERE APPLICABLE
S5
LINE INDICATES DIRECTION OF REINFORCING FOR EACH NOTATION
TYPICAL SUPPORTED SLAB CORNER REINFORCING, RE: TYPICAL DETAILS
(8)#6Bx8'-0"@12"OC ADD
(8)#6Bx8'-0"@12"OC ADD
(4)#6Bx6'-0" ADD
ADDITIONAL REINFORCING LAYOUT:
FOR REINF WITH SPECIFIED QUANTITY AND SPACING, PLACE REINF GROUP CENTERED ON COLUMN LINE
FOR REINF WITH NO SPACING SPECIFIED, PLACE REINF GROUP TO FILL EXTENTS BETWEEN ADJACENT COLUMN LINE REINF
CENTER BOTTOM REINF IN BAY, UNO
CENTER TOP REINF OVER COLUMNS, UNO
REINF GROUP CENTERED ON
COL LINE
REINF GROUP CENTERED ON
COL LINE
FILL EXTENTS BETWEEN
ADJACENT GROUPS
PROJECT DESCRIPTION
1. Project consists of 3 levels above grade. Foundations consist of drilled
piers and grade beams on void form. Superstructure is a combination of
light framed wood construction and partial PT slab at the second floor.
Lateral systems are wood panel shear walls and ordinary reinforced
concrete shear walls.
2. This description is for general orientation only. The General Contractor is
responsible for all scope items described in the drawings and project
specifications as well as for all material and labor that can reasonably be
inferred there from.
GENERAL APPLICATION
1. These drawings must be used in conjunction with the architectural
drawings on the project to clearly define all requirements for construction.
2. No Contractor should attempt to bid nor construct any portion of this
project without consulting the project architectural, mechanical, and
electrical documents.
3. All things which, in the opinion of the Contractor, appear to be
deficiencies, omissions, contradictions or ambiguities in the drawings shall
be brought to the attention of the Structural Engineer. Corrections or
written interpretations shall be issued before affected work may proceed.
4. The Contractor shall inform the Structural Engineer, clearly and explicitly
in writing of any deviation or substitution from requirements of the
contract documents. Contractor shall not be relieved of any requirement
of the contract documents by virtue of the Structural Engineer's review of
shop drawings, project data, etc., unless the Contractor has clearly and
explicitly informed the Structural Engineer in writing of any deviations or
substitutions at time of submission.
MISCELLANEOUS NOTES
1. The Contractor is solely responsible for all safety regulations, programs
and precautions related to all work on this project.
2. The Contractor is solely responsible for the protection of persons and
property either on or adjacent to the project and shall protect it against
injury, damage, or loss.
3. Means and methods of construction and erection of structural materials
are solely the Contractor's responsibility.
4. The structure is designed to function as a unit upon completion of
construction of the project and then, only to support the design loads
indicated. The Contractor is responsible for means, methods and
sequence of construction and the adequacy of the structure to support
loads occurring during construction of the project. Furnish all temporary
bracing, shoring, and/or support as may be required.
5. No openings, nor any change in size, dimension or location shall be made
in any structural element without written approval of the Structural
Engineer.
6. Where dimensions or weights of MEP. equipment or systems are variable
from manufacturer to manufacturer, verify dimensions and weights
shown on drawings with selected manufacturer prior to ordering
materials. Notify Structural Engineer of discrepancies.
7. Do not place equipment when shipping or operating weight exceeds
weight indicated on structural drawings.
8. Openings 1'-4" or less on a side are generally not shown on the structural
drawings. Refer to drawings of other consultants for such openings.
9. Openings through floors and/or roofs for passage of utilities are not
located nor dimensioned on structural drawings. Contractor shall obtain
and coordinate such locations and dimensions with the contractor
requiring the opening.
10. Show all openings through structural members on shop drawings and
submit for review. Openings not shown on structural drawings are subject
to acceptance and shall be specifically indicated for review and
acceptance.
11. Verify elevator pit dimensions, locations, loadings, and details with the
elevator supplier prior to the fabrication and/or installation of any
material.
12. Fireproofing of structural elements is not shown on the structural
drawings. Refer to the specifications and architectural documents.
13. Do not scale these drawings, use the dimensions shown. In case of
conflict, request clarification from Architect and Structural Engineer.
14. No structural modifications, alterations, or repairs shall be made without
prior review by Structural Engineer. Submit details and calculations
prepared by a professional engineer registered in state where project is
located and employed by Contractor.
Wind Loading
Basic Wind Speed Vult = 150 MPH Vasd = 116 MPH
Exposure Category B
GCpi +/- 0.18
Wind Base Shear - Ultimate
139 K
Wind Design Pressure
Components & Cladding - ASD50ft2
East/West
North/South
Seismic Loading
1.0
Mapped Spectral Response Acceleration
Seismic Importance Factor, Ie
0.199SS
0.061S1
CSite Class
Spectral Response Coefficients
.212SDS
.098SD1
BSeismic Design Category
Light Frame Wood Walls with
Structural Wood Shear Panels
Basic Seismic Force Resisting System
6.5Response Modification Factor, R
0.033Seismic Response Coefficient, Cs
Equivalent Lateral-Force ProcedureAnalysis Procedure Used
Seismic Base Shear - Ultimate
91.34 KEast/West
91.34 KNorth/South
Snow Loading
30 PSFGround Snow Load, Pg (Colorado
Design Snow Loads 2016, SEAC)
30 PSFMinimum Flat Roof Snow Load, Pf
1.0Importance Factor, Is
BTerrain Category
1.0Exposure Factor, Ce
1.0Thermal Factor, Ct
1.0Slope Factor, Cs
Live Loads and Superimposed Dead Loads
Foundations
45 PCFActive Equivalent Fluid Pressure (Drained)
67 PCFAt-Rest Equivalent Fluid Pressure (Drained)
346 PCFPassive Equivalent Fluid Pressure (Drained)
0.30Sliding Friction Coefficient
36 INMinimum Frost Depth
(Notes 2,3,4,6)
(Notes 5,6)
Local Jurisdiction: City of Boulder
Building Code: 2012 International Building Code
Geotechnical Engineer Information: Susan Rafalko PE# 46028
Olsson
3390 Fox St
Denver, CO 80216
303-237-2072
Date of Report: 05/03/2019
S-500Foundation Schedule Located on:
-20.9 PSFInterior Roof Zone (Zone 1)
-28 PSFRoof End Zone (Zone 2)
-28 PSFCorner Roof Zone (Zone 3)
-19.9 PSFInterior Wall Zone (Zone 4)
-22.9 PSFWall End Zone (Zone 5)
STRUCTURAL DESIGN CRITERIA
Risk Category: II
20ft2
-21.6 PSF
-33.3 PSF
-33.3 PSF
-21.1 PSF
-25.3 PSF
100ft2
-20.3PSF
-24.1PSF
-24.1 PSF
-19.0 PSF
-21.1 PSF
18 KSFDrilled Pier End Bearing
1.8 KSFAllowable Skin Friction
15 KSFMinimum Dead Load Pressure
3 FTMinimum Pier Socket Length
100'-0"= First Floor Elevation
5272'-0" = USGS Referenced Datum
NOTES:
1. The governing building code defines the applicable edition of referenced
codes and standards. Where governing building code does not define
referenced codes and standards, the latest edition shall be used.
2. Ground snow load is according to the City of Boulder Building
Department on 02/25/2019.
3. Minimum flat roof snow load according to the City of Boulder Building
Department on 02/25/2019.
4. All snow loads on the structure for both flat and sloped roofs are
calculated in accordance with the 2012 IBC and based on the ground
snow load stated above. Roof snow loads consider the following load
conditions: partial loading, unbalanced roof snow loads, snow drifting,
and sliding snow.
5. Minimum uniform and concentrated live loads as well as partition loads
and applicable live load reductions are determined according to Section
1607 of the IBC.
6. See Load Keys for numerical definition and area designation of snow, live,
and other gravity loads used in design.
180 K
2.5Over-Strength Factor, Ωo
4Deflection Amplification Factor, Cd
Parapet 40.8 PSF47.4 PSF 35.8 PSF
QUALITY ASSURANCE
1. The Contractor is responsible for quality assurance, including
workmanship and materials furnished by subcontractors and suppliers.
2. Inspection or testing by the Owner does not relieve the Contractor of his
responsibility to perform the work in accordance with the Contract
Documents.
3. Workmanship: The Contractor is responsible and shall bear the cost of
correcting work which does not conform to the specified requirements.
4. Correct deficient work by means acceptable to the Architect. The cost of
extra work incurred by the Architect to approve corrective work shall be
borne by the Contractor.
QUALITY CONTROL
1. The Owner's Testing Agency shall perform testing and special inspections
required by the structural documents, building code and the local
authority. The Testing Agency shall comply with ASTM E329 and upon
completion of work, the Testing Agency shall furnish a certificate of
compliance, signed by the professional engineer overseeing special
inspections and testing. The professional engineer must be registered and
licensed in the state where the project is located.
2. The individual employed by the Testing Agency, responsible for
overseeing testing and inspection of soils and foundations shall be a
professional engineer practicing the discipline of geotechnical
engineering, referred to as the Geotechnical Engineer in the structural
portion of the construction documents. The Geotechnical Engineer is
responsible for testing and inspections of soils, earthwork and foundations
for conformance to the foundation design and the geotechnical report.
See foundation section of the general notes.
3. See special inspections section of the general notes for required testing
and inspection.
SPECIAL INSPECTION
1. Special inspection and testing shall be performed as required by the local
jurisdiction, the building code and the construction documents. See
quality assurance section of the general notes.
2. Coordinate and schedule inspection and testing prior to the start of work
requiring inspection and testing while providing special inspector
reasonable notice.
3. All deficiencies shall be corrected for acceptance by the testing agency.
4. Inspections performed by the local jurisdiction do not replace inspection
or testing required by the owners testing agency.
5. Special inspection and testing is required for the items shown in the
special inspections and testing table.
SPECIFICATIONS
1. General Notes are not a substitute nor a replacement for the project
specifications. These notes are intended as a guide to the design and/or
construction requirements established for this project.
SPECIAL INSPECTIONS AND TESTING
ClassCategory/Material
4321Component/Work
So
ils
an
d
Fo
un
da
tio
ns
XSlab-on-Grade Subgrade Material
XXXCompaction
XXX
X
XXX
X
XX
XX
XX
XX
Drilled Pier Load Testing and/or Sonic Echo Testing
Drilled Pier Drilling and Drilled Pier Soil Embed
Material
Permanent Soil Retention Elements
Formwork Installation
Reinforcing Placement
Steel Embeds
Cast Embedded Anchors
Concrete Strength, Slump, Temperature, and Air
Content
X
X
XX
Concrete Placement
Concrete Curing
Post-Installed Anchors in Overhead Applications
XXWelded Reinforcing
Ca
st-i
n-P
lace
Co
ncr
ete
X
XXFabrication Facility
XXStructural Steel Erection
XXConnection Erection and Assembly
Pretensioned and Slip Critical Bolts/Joints Using
Turn-of-Nut without Matchmarking or
Calibrated Wrench Methods of Installation
XXXSingle Pass Fillet Welds 5/16" or Less
All Other Welds Including Complete and Partial
Penetration Groove Welds
XXShear Stud Placement
XXPrefabricated Wood Joists and Trusses
XXX
XXX
S
tru
ctu
ral
Ste
el X
XXJoists and Beam Framing
XXInterior Bearing Wall Studs
XXExterior Stud Framing
Shear Wall Framing, Sheathing, Nailing, Anchors,
and Holdowns
XXDrag Struts and Collectors
XXFloor/Roof Sheathing and Nailing
XXHangers and Connections
XXMechanical, Electrical, and Plumbing Penetrations
Wo
od
Fra
min
g
XX
NOTES:
1. Special inspection and testing are to conform to chapter 17 of the IBC and the local
building department.
2. Unless noted as continuous inspection, all inspections are periodic. Periodic inspection
is defined as part-time or intermittent inspection of the work. It is the Special
Inspector's responsibility to determine and coordinate the frequency and duration of
the inspection relative to the Contractor's schedule and sequencing of the work in
order to meet the inspection and reporting requirements.
3. Class 1: Inspection verification of size, location, quantity, and tolerance.
4. Class 2: Inspection and testing verification of strength, grade, classification, quality,
density, proportions, and manufacturers certified test reports.
5. Class 3: Continuous inspection and verification of operations and conditions.
6. Class 4: Audit and inspection of fabrication facility's quality control program, and
collection of facilities records during the course of fabrication for Class 2 and 3
inspections and testing.
7. Class 5: Verification of certifications
X
XXConnection Erection and Assembly
Pretensioned and Slip Critical Bolts/Joints Using
Turn-of-Nut without Matchmarking or
Calibrated Wrench Methods of Installation
XXXSingle Pass Fillet Welds 5/16" or Less
All Other Welds Including Complete and Partial
Penetration Groove Welds
XXShear Stud Placement
XXX
XXX X
Fa
bri
cati
on
Ere
ctio
n
XMasonry Units, Grout and Mortar
Preparation of Mortar and Construction of Mortar
Joints
XX
XX
XX
X
XX
XX
Reinforcing Placement
Mortar Joint Reinforcing and Placement
Grout Placement
Control and Construction Joints
Steel Embeds
Cast Embedded Anchors
XXXPost-Installed Anchors
XCuring
Re
info
rce
d M
aso
nry
XX
Verification of f'm prior to construction XX
XGrout Space
X
XXVerification of mix design use on site (prior to
placement)
XXAll Other Post-Installed Anchors
X
5
Post-Tension Placement X X X X X
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Coloradop: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
14:5
6 A
M
S000GENERAL NOTES
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NEW SHEET = ñ REVISED DRAWING = òNO MODIFICATIONS = ó SHEET DELETED = ô
SHEETNO. SHEET NAME
ISSUE DATE ANDTITLE
100%
DD
03/15/2019
50% C
D 0
5/17/2019
PER
MIT 0
7/03
/2019
S000 GENERAL NOTES ñ ò òS001 GENERAL NOTES ñ ò òS002 GENERAL NOTES ñ ò òS003 LOAD KEYS ñ ò òS010 TYPICAL DETAILS - CONCRETE ñ ò òS011 TYPICAL DETAILS - CONCRETE ñ ò òS012 TYPICAL DETAILS - WOOD ñ ò òS013 TYPICAL DETAILS - MASONRY ñ ò òS014 TYPICAL DETAILS - STEEL ñ ò òS015 POST-TENSIONED ñ ò òS016 POST-TENSIONED ñ ò òS161 FOUNDATION AND 1ST FLOOR PLAN ñ ò òS162 LEVEL 2 FRAMING PLAN ñ ò òS162PT LEVEL 2 PT TENDON PLANS ñS162R LEVEL 2 REINFORCEMENT PLAN ñS163 LEVEL 3 FRAMING PLAN ñ ò òS164 ROOF FRAMING PLAN ñ ò òS300 CORE WALL ELEVATIONS ñ òS400 FOUNDATION DETAILS ñ ò òS410 FRAMING DETAILS ñ ò òS411 FRAMING DETAILS ñ òS500 SCHEDULES ñ ò òS501 SCHEDULES ñ
ABBREVIATIONS
ADDNL additionalAFF above finish floorALT alternateARCH architectural
BLDG buildingBM beamBOT, B/, BOx bottom of (S=slab, C=conc, etc)BRG bearingBS both sidesBTWN between
CFS cold-formed steelCIP cast-in-placeCJ construction / control jointCJP complete joint penetrationCLR clearCMU concrete masonry unitCOL columnCONC concreteCONN connectionCONST constructionCONT continuous
D depthDIA, T diameterDIM dimensionDTL detailDWGS drawingsDWL dowel
(E) existing constructionEA eachEF each faceELEV elevationEOx edge of (S=slab, C=conc, etc)EW each wayEXP expansionEXT exterior
FDN foundationFLR floorFOx face of (S=slab, C=conc, etc)FS far sideFTG footing
GA gageGB grade beamGC general contractorGEN generalGLB glulam
HDR headerHORIZ horizontalHSA headed stud anchor
IF inside faceINT interior
JST joist
KIP, K 1000 poundsKLF 1000 pounds per lineal foot
L lengthLAT lateralLBS poundsLLH long leg horizontalLLV long leg verticalLONG longitudinalLSL laminated strand lumberLVL laminated veneer lumberLW, LWT lightweight
MAS masonryMAX maximumMECH mechanicalMFR manufacturerMIN minimumMTL metal
(N) new constructionNo NumberNOM nominalNS near sideNW, NWT normal weight
OC on centerOF outside faceOH opposite handOPNG opening
PAF powder actuated fastenerPERP perpendicularPJP partial joint penetrationPL, V platePLF pounds per lineal footPSL parallel strand lumberPT post-tensioningPT pressure treated
RE: referenceREINF reinforcementREQD required
SC slip criticalSCHED scheduleSCL structural composite lumberSOG slab on gradeSTFNR stiffenerSTL steel
T/, TOx top of (S=slab, C=conc, etc)TRAN transverseTYP typical
UNO unless noted otherwise
VERT verticalVIF verify in field
WP work pointWWF welded wire fabric
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
FOUNDATIONS
GENERAL:
1. The foundations have been designed based on the design criteria and the
Geotechnical Report referenced in the Structural Design Criteria section.
Earthwork and foundation soil preparation shall be performed to provide
soil properties meeting the design criteria.
2. The Geotechnical Engineer shall inspect and test soils, earthwork and
foundations - see special inspection and quality assurance sections of the
general notes. Prior to placing foundations and slabs-on-grade, obtain
approval from the Geotechnical Engineer indicating earthwork and soil
preparation has been performed adequately to conform to the foundation
design criteria.
3. Bottom of exterior footings, grade beams, and walls shall bear below final
exterior grade for frost protection - see structural design criteria section of
the general notes.
4. Foundation walls or grade beams having earth placed on each side shall
have both sides filled simultaneously to maintain a common elevation.
5. Brace all foundation walls against movement while backfilling until floor
slabs at the top and bottom of the wall are in place. Brace foundation
walls as necessary to prevent movement and overstress due to equipment
loading regardless of sequencing of top and bottom floor slabs.
6. Contractor shall provide continuous site drainage by a mechanical method
to control surface and underground water as required to maintain a dry
working site.
7. Foundation drainage and waterproofing is not shown or specified within
the structural portion of the construction documents. Reference other
portions of the construction documents for drainage, waterproofing and
items associated with other disciplines.
SUBMITTALS
1. See Material sections of these General Notes for required shop drawings.
2. Submit one (1) copy of the required information (Manufacturers Data,
Shop Drawings, etc) via electronic media (PDF or similar).
3. Reproducible copies of contract documents shall not be used.
4. Submittals shall be sent directly to the Architect for review and
distribution.
5. Submittals shall be reviewed by Contractor and Subcontractor prior to
submission. Drawings shall bear Contractor's approval stamp accepting
responsibility for coordination of dimensions shown in the contract
documents, quantities and coordination with other trades.
6. Allow 14 calendar days in the Structural Engineer's office for review of
submittals.
7. Submittals will be returned to the Architect with Structural Engineer's
review comments via electronic media.
DEFERRED SUBMITTALS
1. Submit shop drawings along with calculations noted to be signed by a
registered Engineer in the state where the project is located when
required by specification. These deferred submittals (shop drawings) shall
first be submitted to the project Architect and/or Engineer of record for
review and coordination. Following the completion of the review and
coordination by the Architect/Engineer of record; a submittal may then be
made by the Contractor to the local Building Department for review and
approval, which shall include a letter stating this review and coordination
has been performed and completed and plans and calculations for the
deferred items are found to be acceptable (e.g., with regard to geometry,
load conditions, etc.) with no exceptions.
2. The list of items for deferred submittals includes the following items:
Pre-fabricated stair units and their connections
Premanufactured hand/stair railings and their connections
Premanufactured wood trusses
All others required by the local jurisdiction
CAST-IN-PLACE CONCRETE
GENERAL:
1. All concrete work shall conform to ACI318 and ACI 301 and tolerances
shall conform to ACI 117 unless noted otherwise. Contractor shall keep a
copy of these references on site at all times.
2. Concrete Compressive Strength – See "Concrete Mix Design
Requirements" table
3. Materials – See "Concrete Materials Designation" table
TESTING:
1. Tests and inspections shall be performed in compliance with ACI 301 and
Chapter 17 of the IBC. See Special Inspections.
2. Concrete shall not be placed until reinforcing and embedded items have
been inspected by the owner's independent inspection agency and/or the
special inspector.
3. See "Special Inspections and Testing" Table.
SUBMITTALS:
1. Submittals shall conform to ACI 301 .
2. Submittals for all concrete shall include: mix designs, construction joint
locations, reinforcing, embedded items, and MEP sleeves and
penetrations.
3. Submittals for architecturally exposed concrete shall also include: form
facing materials and mock-ups if required by the Architect.
4. Submittals for suspended concrete (suspended slabs, frames, joists, and
beams) shall also include reshoring and backshoring plans and
calculations. Shop drawings and calculations shall be signed and sealed by
a Professional Engineer licensed in the state where the work will be done.
5. Reinforcing shop drawings shall include placement drawings 1/8"=1'-0”
minimum scale complete with wall elevations and slab plans. Include
special reinforcement required at openings through concrete structure.
Include all accessories specified and required to support reinforcement.
Detailing of reinforcing shall conform to ACISP-66.
6. Embed shop drawings shall include placement drawings 1/8”=1’-0”
minimum scale locating all embed plates, anchors, and anchor bolts for
structural and non-structural components attaching to concrete.
Contractor is responsible for coordinating with all trades for determining
the need for embeds and locations. Post installed anchors are not allowed
unless approved by the structural engineer during the shop submittal
process.
FORMING:
1. Unless noted otherwise, all formwork shall conform to Class B finish in
accordance with ACI 117 unless noted otherwise by architectural
drawings. Refer to architectural drawings for architectural finish concrete.
2. All construction joints shown on the drawings shall be incorporated into
the structure unless elimination is approved by the Structural Engineer.
Additional joints required to facilitate construction shall be located at
points of minimum shear and shall be detailed on reinforcing shop
drawings for review. Locate vertical joints in girders, beams, grade beams,
joists, walls and slabs within the middle third between supports designed
and detailed with dowels and keys for transfer of design shear, unless
noted otherwise. Reinforcing shall pass continuously through construction
joints. Where joints are shown as roughened, mechanically roughen
surface to 1/4" amplitude clean and free of laitance.
3. Unless otherwise shown in the architectural drawings, provide chamfers
at all columns, beams, walls, and slab edges that are exposed to view in
the finished structure.
4. Unless otherwise shown in the architectural drawings, provide drip edges
at the underside of all exposed slab edges.
5. Locate door openings, window openings, MEP openings, drip slots,
reglets, brick ledges, curbs, and ledges per architectural drawings. For
openings not dimensioned on structural drawings refer to architectural
drawings.
6. Provide void forms under foundation elements as shown on the drawings.
REINFORCING AND EMBEDDED ITEMS:
1. Provide standard hooks on bars terminating at a concrete face unless
noted such as at edges of openings, slab edges, expansion joints, ends of
beams, and ends of walls.
2. Unless noted otherwise, provide (2) #5's at each side of openings. Extend
2'-0" beyond edges of opening.
3. Unless noted, splice continuous top and bottom bars in grade beams and
walls as follows: top bars at mid-span, bottom bars over support.
4. Splice bars with class B contact laps per the reinforcing contact lap splice
length table, unless noted otherwise.
5. Splice welded wire fabric by lapping one full mesh space plus 2".
6. Unless noted, provide continuous reinforcing around corners and through
construction joints, control joints, contraction joints, and joints between
all abutting members. Provide epoxy coated reinforcing through
construction joints at garage slabs and slabs exposed to de-icers.
7. Masonry Dowels: provide, place, and space to match masonry horizontal
and vertical reinforcing.
8. Welding of reinforcing is prohibited, unless noted otherwise and shall
conform to ASTM A706.
9. Provide embeds (including anchors) for all supporting structural and non-
structural elements including but not limited to hand rails, canopies,
window washing davits, miscellaneous steel, bollards, etc.
PLACING AND FINISHING:
1. Handling, placing, constructing, and curing shall conform to ACI 301
including placement of concrete in wet weather, cold weather, and hot
weather.
2. Curing compounds should not be used on surfaces that are to receive
additional concrete, paint, tile, or other material requiring a positive bond
unless the contractor has demonstrated that the membrane can be
satisfactorily removed before subsequent application is made, or the
membrane dissipates or can serve satisfactorily as the base for the later
application.
3. All concrete work shall be poured in-place unless noted otherwise.
Shotcrete placement method will only be permitted if approved by the
structural engineer prior to permit submittal.
EMBEDDED ITEMS IN STRUCTURAL CONCRETE SLABS
GENERAL:
1. See mechanical, electrical and plumbing (MEP) drawings for miscellaneous
plates, anchors, fittings, etc. required for MEP equipment and service.
2. See architectural drawings for miscellaneous plates, bolts, reglets, slots,
etc. required for architectural items.
3. Electrical conduit in PT slabs consisting of PVC, uncoated or galvanized
iron, and steel are acceptable (aluminum not allowed) provided the
following: conduit shall not alter or displace PT tendons and reinforcing in
plan or elevation; conduit shall not be larger in outside diameter than the
smaller of 1/3 of the overall thickness of slab or 1 1/2"; conduit shall be
placed within the middle 1/3" of the slab; minimum spacing between
parallel conduits shall be 3"; minimum horizontal distance between
parallel conduit and PT tendon/ reinforcing shall be 3"; minimum vertical
distance between tendon and crossing conduit shall be 2"; and crossing
conduit shall consist of no more than two layers.
4. Channel and slot type embeds in slabs for support of MEP and other
equipment are not allowed without prior approval of Structural Engineer.
POST INSTALLED ANCHORS IN CONCRETE AND MASONRY
GENERAL:
1. Holes are assumed to be dry unless otherwise noted on plans.
2. Holes to be hammer drilled with bit as specified by anchor manufacturer.
3. Anchors specified are based on the specific technical data published by
the specified anchor manufacturer. Substitutions are not permitted
without approval by the Structural Engineer of Record prior to
use. Contractor shall provide calculations demonstrating that the
substituted product is capable of achieving the performance values of the
specified product. Substitutions will be evaluated by their having an ICC
ESR showing compliance with the relevant building code for seismic uses,
load resistance, installation category, and availability of comprehensive
installation instructions. Adhesive anchor evaluations consider creep, in-
service temperature and installation temperature.
4. Install anchors per the manufacturer instructions, as included in the
anchor packaging. Installation shall adhere to ICC ESR. Reference plans
and details for anchors that are to be installed with reduced torque.
5. Concrete should be allowed to cure a minimum of 21 days prior to
adhesive anchor installation.
6. Prior to installation of anchors all installation and inspection personnel
shall be instructed on site by a representative of the anchor manufacturer
on proper installation techniques and equipment.
7. Anchor capacity is dependent upon spacing between adjacent anchors
and proximity of anchors to edge of concrete. Install anchors in
accordance with spacing and edge clearances indicated on the drawings.
8. Installation of anchors shall not damage existing reinforcing, which
includes post-tensioned tendons (PT). Prior to drilling, care shall be taken
to avoid damage by locating existing reinforcing and PT by use of GPR, X-
Ray, or other means that avoids damage to the concrete and accurately
predicts potential conflict of reinforcing and PT.
9. Post-installed anchors to be stainless steel where exposed to exterior
and/or corrosive environments unless the anchor is protected.
10. All installers of post-installed adhesive anchors horizontally, vertically or
upwardly inclined in concrete to support sustained tension loads shall be
certified by ACI/CRSI adhesive anchor installer certification program, or
equivalent as required by the IBC. Submit certificates for record.
11. All post-installed anchors in concrete shall be suitable for use in cracked
concrete applications.
12. When doweling continuously deformed rebar into concrete use Hilti
RE-500v3 or an adhesive that has been approved under ACI 355.4 and ACI
318 for development and lap splices.
13. Unless noted otherwise on plans/details all adhesive anchors shall be Hilti
HIT-HY200 Safe-Set for concrete and Hilti HY-70 for block and brick.
Unless noted otherwise on plans/details all expansion anchors shall be
Hilti Kwik-Bolt TZ. See note 3 for substitutions.
Element
Drilled Piers 4000, NW
GENERAL CONCRETE MIX NOTES:
1. Strength (f`c) is the 28 day compressive strength at 28 days unless noted
otherwise or compressive strength at the specified age.
2. Concrete is normal weight concrete unless noted otherwise. Normal weight
concrete (NW) shall have a dry density of 145 ± 5 pcf unless noted otherwise.
3. Required minimum average splitting tensile strength = 6.7*√(f'c) regardless of
concrete density.
4. Mix designs shall be in accordance with ACI 301.
5. Exposure Class indicates the severity of the anticipated exposure of concrete
members for each exposure indicated below according to ACI 318/ACI301.
Freeze Thaw Exposure noted thus: F0,F1,F2,F3
Water-Soluble Sulfate in Soil Exposure noted thus: S0,S1,S2,S3
Permeability Requirements noted thus: [P0,P1/W0,W1]
Corrosion Protection of Reinforcement noted thus: C0, C1, C2
Refer to ACI 301/ACI 318 for specific requirements based on the exposure
category indicated in the mix design table above
6. Corrosion Protection of Reinforcement requirements (C0,C1,C2):
Maximum water-soluble chloride ion (CL-) content in concrete, by % weight of
cement
Reinforced Concrete: C0 = 1.0 C1 = 0.3 C2 = 0.15
Prestressed Concrete: C0 = 0.06 C1 = 0.06 C2 = 0.06
7. Where concrete is exposed to F3 freeze thaw exposure, restrictions on maximum
fly ash and/or other cementitious materials apply. Refer to Table 4.4.2 in ACI 318
for requirements
CONCRETE MIX DESIGN REQUIREMENTS
-
MaxW/C
MaxAgg
1"
f'c (psi) Slump
6"-8"
ExposureClass
AirContent
-I/II
CementType
1,2 3
F0,C0
S0,P0
Columns5000, NW
UNO0.40 3/4" -I/II
PT Slab
Exterior Slab-On-Grade
5000, NW
3800 at 3
days
0.40 3/4" -II
5000 NW 0.40 3/4" 5I/II
Grade beams4500, NW 0.45 3/4" 5I/II
4
Other 5000, NW 0.45 3/4" -I/II
TABLE FOOTNOTES:
1. Minimum air content equals 5% if concrete is exposed to freezing temperature and
moisture regardless of value indicated in table.
2. Tolerance on air content as delivered shall be +/- 1.5% for f'c <= 5000 psi, 1.0% for
f'c>5000 psi
3. Slump tolerances as follows (ACI 117)
Specified Slump not greater than 4"= +/- 1"
Specified Slump more than 4"= +/- 1 1/2"
Where Slump is specified as a range= No Tolerance
See ACI 301 for slump of concrete before addition of plasticizers or high-range water
reducing admixtures
4. Refer to concrete column schedule for additional strength requirements
4"
4"
4"
4"
4"
Core, Shear and Bearing
Walls5000, NW 0.40 3/4" -I/II 4"
F1,C0
S0,P0
F1,C0
S0,P0
F1,C0
S0,P0
F1,C0
S0,P0
F1,C0
S0,P0
F1,C0
S0,P0
Concrete cast against & permanently exposed to earth
Assembly Cover (in)
3
REQUIRED CONCRETE COVER FOR NON-FIRE-RATED
ASSEMBLIES
#6-#18 (non-post-tensioned)
Co
ncr
ete
no
t
Exp
ose
d t
o
Ea
rth
or
We
ath
er
Walls, slabs #14-#18 (Non-Post-tensioned)
Walls, slabs #11 and smaller
Columns, beams, girders
2
#5 and smaller (Non-Post-tensioned) 1 1/2
Co
ncr
ete
Exp
ose
d t
o
Ea
rth
or
We
ath
er
1 1/2
3/4
1 1/2
AssemblyCover (in)
REQUIRED CONCRETE COVER FOR FIRE-RATED ASSEMBLIES
Columns, beams, girders
Slabs
Re
info
rcin
g
Ste
el
NOTES:
1. Cover for prestressed & non-prestressed reinforcement
2. Primary reinforcement, ties, stirrups, and spirals
3. Primary reinforcement
4. Ties and stirrups
5. Cover for studrails shall match cover to primary reinforcement.
1 hr 2 hr 3 hr 4 hr
NOTES:
1. Clearances are the clearance between reinforcing and concrete surface. Unless noted
otherwise in drawings, specified in-place cover shall be the greater of the appropriate
not-fire-rated and the fire-rated. In-place cover shall not exceed tolerances specified
in ACI 117.
2. Tabulated values for siliceous aggregate.
3. Cover for studrails shall match cover to primary reinforcement.
4. Slabs and beams are considered restrained.
2
1 1/2 1 1/2 1 1/2 2
3/4 1 1 1 1/4
Portland Cement
Material Standard
ASTM C150, Type I or Type II
CONCRETE MATERIALS DESIGNATION
ASTM C618, Class C or FFly Ash
ASTM C33Aggregate
PotableWater
ASTM C494, Type A or Type DWater Reducing Admixture
High Range Water Reducing Admixture
Accelerator Admixture
ASTM C260Air Entraining Admixture
ASTM C330Lightweight Aggregates
ASTM C309, Type I, Class ACuring Compound
ASTM A615-grade 60
(Specified Yield Strength = 60ksi)Reinforcing Bars
ASTM A706-grade 60
(Specified Yield Strength = 60ksi)Welded Reinforcing Bars
ASTM A185Welded Wire Fabric
ASTM E1745-Class AVapor Retarder below SOG
ASTM C494, Type F or Type G
ASTM C494, Type C or Type E
NOTES:
1. Type III Portland cement may be used if acceptable to the
Architect.
Epoxy Coated Reinforcing Bars ASTM A775 or ASTM A954
Post-Tensioning Tendon Assembly ACI 423.7
Post-Tensioning Prestressing Steel ASTM A416-grade 270
CONCRETE COMPRESSION STRENGTH (psi)
CONCRETE REINFORCING TENSION CONTACT
LAP SPLICE LENGTHS
Cla
ss B
Cla
ss A
Ca
se #
2C
ase
#1
Ca
se #
1C
ase
#2
Bars
≥ #7
Top
Other
57 db
44 db
3,000 4,000 5,000 6,000 8,000
71 db
55 db
85 db
66 db
107 db
82 db
74 db
57 db
93 db
71 db
111 db
85 db
139 db
107 db
49 db
38 db
62 db
47 db
74 db
57 db
92 db
71 db
64 db
49 db
80 db
62 db
96 db
74 db
120 db
92 db
44 db
34 db
55 db
42 db
66 db
51 db
83 db
64 db
57 db
44 db
72 db
55 db
86 db
66 db
108 db
83 db
40 db
31 db
50 db
39 db
60 db
46 db
76 db
58 db
52 db
40 db
65 db
50 db
79 db
60 db
98 db
76 db
35 db
27 db
44 db
34 db
52 db
40 db
65 db
50 db
45 db
35 db
57 db
44 db
68 db
52 db
85 db
65 db
Where:
Class B: Class B tension splice
Case #1:
Class A: Class A tension splice
Clear spacing greater than or equal to 2*db AND cover greater than or
equal to db.
Case #2: Clear spacing less than 2*db or cover less than db.
Top: Where horizontal reinforcement is placed such that more than 12 inches
of fresh concrete is cast below the development length or splice.
Other: Other condition not satisfying Top qualification (bottom horizontal
reinforcing)
db: Diameter of reinforcing bar
NOTES:
1. All tension splices shall be contact class B splices unless noted otherwise. Splice
length shall not be less than 12 inches.
2. Splice Lengths in table are for single bar splices with maximum yield strength of 60ksi
non-epoxy reinforcing bars.
3. For epoxy coated bars; zinc and epoxy coated bars; or epoxy coated wires multiply
"Bot" reinforcing splice length by 1.5 and multiply "Top" reinforcing splice lengths by
1.31
4. For lightweight concrete multiply splice length by 1.33.
5. For reinforcing with a specified yield strength greater than 60ksi multiply splice length
by (specified yield strength/60ksi)
6. For individual bars within a bundle lap lengths shall be multiplied by 1.33 for four-
bundles and 1.20 for three bar bundles. Individual splices within a bundle shall not
overlap. Entire bundle shall not be lap spliced.
7. Bars larger than #11 shall not be lap spliced. For bars larger than #11, mechanical
splice shall be used. Mechanical splices shall have strength greater than or equal to
125% the yield strength of the reinforcing bar. Mechanical splices shall be staggered.
8. Where bar of different size are lap spliced in tension the minimum splice length shall
be the larger of the length of a Class B tension splice of the smaller bar, or the length
of a Class A tension splice of the larger bar.
9. Lap splices are not permitted where minimum clearance between reinforcing cannot
be maintained.
10. Lap splice lengths shall not be less than the larger of 12 inches multiplied by all
applicable multipliers or the table length multiplied by all applicable multipliers.
Top
Other
Top
Other
Top
Other
Top
Other
Top
Other
Top
Other
Top
Other
Bars
≤ #6
Bars
≥ #7
Bars
≤ #6
Bars
≥ #7
Bars
≤ #6
Bars
≥ #7
Bars
≤ #6
4,500
47 db
36 db
58 db
45 db
70 db
54 db
87 db
67 db
60 db
47 db
76 db
58 db
91 db
70 db
113 db
87 db
POST TENSIONING
GENERAL:
1. All post-tensioning work, material, and fabrication shall conform to ACI
301 and ACI 423.7. Tolerances shall conform to ACI 117.
2. Installer of post-tensioning shall be PTI certified level 2.
3. All tendons anchorages shall be encapsulated. The sheathing shall be
connected to all stressing, intermediate, and fixed anchorages in a
watertight fashion in accordance to ACI 318.
4. Prestressing steel used in post-tension work shall conform to ASTM A416-
Grade 270 1/2 inch diameter 7 wire strand.
5. Concrete shall have attained a minimum compressive strength of 75% of
28 day strength but not less than 3750 psi before post-tensioning
commences.
6. Tendons are unbonded unless noted otherwise.
7. Height (or elevation) of tendons shown on the plans is measured from the
supporting form surface to the center of the tendon at the location
indicated.
8. Stressing sequence (Unless noted otherwise on plans): 60% of banded
thru tendons, then 100% of uniform thru tendons, then 100% of uniform
add tendons, then remaining banded thru tendons, and then 100% of
banded tendons.
TESTING:
1. Tests and inspections shall conform to ACI300 and ACI423.7
2. Inspectors shall be PTI certified level 2 post-tensioning inspectors.
SUBMITTALS:
1. Submittals shall include shop drawings, elongation calculations, stressing
jack calculations, and stressing record specified in ACI301.
2. Shop drawings and elongation calculations shall be signed and sealed by a
licensed engineer in the state where the project is located
3. Submit PTI plant certification and installer PTI certification.
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
14:5
8 A
M
S001GENERAL NOTES
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
A Permit Resubmittal 08/23/2019
A
PROGRESS PRINT 09.04.2019
STRUCTURAL STEEL
GENERAL:
1. All structural steel work shall conform to AISC 360 and tolerances shall
conform to AISC 303 unless noted otherwise. Contractor shall keep a copy
of these references on site at all times.
2. Materials – See Steel Materials Table
3. Qualifications - Fabricator and Erector shall be experienced in fabrication
and erection of projects of similar size and complexity.
TESTING:
1. Tests and inspections shall be performed in compliance with AISC 360 and
Chapter 17 of the IBC. Inspections include: Welding, high strength bolting,
anchor rod placement, proper use of joint details, fabricated steel, and
erected steel frame. Testing includes: UT of full penetration welds, bolt
tensioning procedures, shear stud bend tests.
2. See "Special Inspections and Testing" Table.
SUBMITTALS:
1. Submittals shall conform to AISC 360.
2. Submittals for structural steel shall include erection drawings, shop
drawings, and mill test reports.
3. Erection drawings shall include plan drawings at 1/8"=1'-0” minimum
scale complete with sections, elevations, and details as required to
properly erect the structural steel frame.
4. Shop drawings shall include piece drawings which indicate cuts,
connections, camber, holes, welds and dimensions as required for
fabrication of the members. Part drawings are not required to be
submitted unless specifically requested.
CONNECTIONS:
1. Engineer of Record (EOR) has designed all connections. If a connection
design is inadvertently omitted from contract documents the contractor
shall request specific connection design from the EOR.
2. Connection Design Forces: Unfactored ASD values
3. Simple Beam Connections: Select connections with capacities equal to or
greater than beam reactions shown on the drawings. Single sided
connections shall be detailed to use the maximum number of bolt rows
that can fit into the supported beam web. Double sided connections shall
be detailed such that the angle or bent plate length is at least 60% of the
supported beam "T" dimension.
4. HSS Cap Plates: Provide 1/4" cap plates at top of all HSS columns, uno.
BOLTS:
1. Where indicated on the drawings as slip critical and where oversized or
long-slotted holes are utilized in shear, bolted joints shall be slip critical.
Faying surfaces shall be prepared to meet the requirements of a Class A
surface, and bolts shall be installed to the fully tensioned condition.
2. Where bolts are subject to non-static loading, are utilized to interconnect
parts of a built up compression member, or all Group B fasteners loaded
in tension shall be installed to the fully tensioned condition.
3. Bolts not subject to the requirements for slip critical connections and not
required to be fully tensioned may be installed to the snug-tight condition.
4. A307 bolts may be used only where indicated.
WELDS:
1. Fillet Welds: Size as indicated, but not less than AISC minimum size.
2. Groove Welds: Full penetration unless noted otherwise.
3. Welds are continuous unless noted otherwise.
ACCESSORIES:
1. Headed Stud Anchors: Shop weld except where applied through metal
deck or where shop installation would result in a tripping hazard.
SHOP CLEANING AND PAINTING:
1. Uncoated Steel: All steel not specifically indicated as painted, steel to
receive spray-on-fireproofing or to be galvanized, and faying surfaces of
slip critical connections shall be uncoated. Prepare surface per SSPC-SP1.
2. Primed Steel: Steel indicated to painted, with no specific paint
requirements stated, shall have the surface prepared per SSPC-SP2
minimum and receive one coat of fabricator's standard rust-inhibitive
primer paint applied to a minimum dry-film thickness of 1 mil.
3. Galvanized Steel: Steel indicated to be galvanized shall be cleaned,
prepared, and galvanized in accordance with ASTM A123. Repair minor
defects, damaged areas, and welded joints in accordance with ASTM
A780.
4. Other specified coatings: Where indicated on the drawings, provide
specified coating system as indicated. Clean and prepare steel as required
by the specification or coating manufacture.
ERECTION:
1. No final bolting or welding shall be performed until as much of the
structure which will be stiffened thereby has been properly aligned.
2. Field correction of fabrication or other errors will be permitted only when
approved by the EOR. Finish gas-cut sections in accordance with AWS
D1.1.
WOOD FRAMING
GENERAL:
1. All wood construction work shall conform to ANSI/AF&PA NDS unless
noted otherwise. Contractor shall keep a copy of these references on site
at all times.
2. Materials – See Wood Materials Tables
3. Qualifications – Carpenter shall be experienced in construction of projects
of similar size and complexity and shall be knowledgeable of conventional
light frame construction practices and minimum nailing requirements of
the IBC.
SUBMITTALS:
1. All submittals shall be reviewed by the Contractor prior to
Engineer/Architect review and shall bear Contractor's review stamp.
Contractor is responsible for reviewing submittals for conformance with
all contract documents and coordination with all trades.
2. Submittals are required for the following wood framing elements:
premanufactured wood trusses, heavy timber framing, log framing,
glulam framing, and manufactured framing including I-joists.
3. Premanufactured truss submittals shall include dimensioned layout
drawings that identify truss types, geometries, and locations as well as
truss design calculations that indicate all design loads. Calculations shall be
signed and sealed by the manufacturer's engineer licensed in the state
where the project is located.
4. Manufactured framing submittals shall include dimensioned layout plans
indicating joist and beam types, locations, and connection hardware.
5. Wood I-joist submittals shall include dimensioned layout plans indicating
joist types, locations, and connection hardware.
PRODUCTS:
1. All wood framing shall be at a moisture content of 19% or less and shall be
marked S-Dry (surface dried) or KD (kiln dried).
2. Unless noted otherwise, all sizes noted on these drawings are nominal.
Actual sizes are based on "Minimum Dressed-Dry" dimensions according
to American Softwood and Lumber Standard PS20-10.
3. Unless noted otherwise, all glulam framing sizes are minimum dressed
dimensions in accordance with American Institute of Timber Construction
AITC113.
4. Unless noted otherwise, all manufactured framing sizes are based on
specified manufacturers published information.
5. Wall studs to be Douglas Fir-Larch (DFL) stud grade @16"OC, unless noted
otherwise in the drawings.
6. Wood I-joists: where framing members are noted TJI on the drawings, use
engineered products by Weyerhaeuser or approved equal.
7. Structural Panels: Sheathing for roofs and walls shall conform to APA PS-2
standards. All panels shall be Exposure 1, unless noted otherwise.
8. Sills: Sill plates shall be pressure treated Douglas Fir-Larch stamped to
show compliance with AWPA standards.
PREMANUFACTURED PRODUCTS:
1. Premanufactured wood trusses shall be designed in accordance with the
"Design Specification for light metal plate connected wood trusses" except
where state and local codes are more stringent.
2. Premanufactured wood trusses shall be fabricated in accordance with the
"TPI Quality Control Manual."
3. Premanufactured wood trusses shall be installed in according to "Bracing
Wood Trusses Commentary."
4. Design of wood elements in premanufactured wood trusses shall conform
to NDS.
5. Wood utilized in premanufactured truss construction shall be stress
graded bearing the mark of a recognized grading agency and shall
conform to the rules and service requirements of the American Lumber
Standards Committee PS-20.
6. Truss fabricator is responsible for all member and connection design and
detailing and for all dimensioning, coordination, and erection of trusses.
Contract documents show only basic dimensioning and configurations of
trusses. Detailed positioning and spacing of trusses is the responsibility of
the fabricator.
7. Trusses shall be designed to resist the dead loads of completed
construction and the larger of live, snow, and wind-uplift loads specified
8. Bottom chords shall be designed for the live loads required by the
applicable codes and standards.
9. Metal anchorage devices for the trusses shall be designed for specified
wind uplift less 0.6 (allowable stress design) of the resisting dead load. Toe
nailing of trusses is not permitted.
WOOD FRAMING
CONNECTORS:
1. All bolts, metal connectors, hangers, anchors, and fasteners in contact
with preservative treated wood shall be hot dipped galvanized G90 or
stainless steel type 304 or 316.
2. Provide 5/8" diameter anchor bolts @48"OC at the top of all foundation
elements for attaching sill plates, except at shear walls. See Shear Wall
Nailing Schedule for shear wall anchor bolt spacing. As a minimum,
provide two bolts, each within 12" of the ends of each piece of sill plate.
3. J and L type bolts are allowed for anchorage of wood sills.
4. Anchor bolts shall be cast into concrete or grouted into masonry with a
minimum embedment of 7".
5. Provide plate washers at all shear wall anchor bolt connections to wall
plates. See "Typical Wood Shear Walls - Nailing Schedule and Details" for
more information.
6. Nailing shall conform to the minimum requirements contained in Table
2304.10.1 of the IBC unless more stringent requirements are shown on
these drawings or in these notes.
7. All nails are to be steel common wire nails and conform to ASTM F1667.
8. Pre-drill nail holes when necessary to prevent splitting.
9. Steel plates for wood construction shall conform to ASTM A36.
10. Bolts shall conform to ASTM A307.
11. All exposed bolts in wood structure which are not in contact with
preservative treated wood shall be plain, uncoated steel.
12. Holes for bolts shall be 1/16" oversized.
13. Retighten all bolts prior to closing in.
14. Lag screws shall penetrate the main member a minimum of eight times
the shaft diameter unless noted otherwise.
15. Diagonal (toe-nail) lag screws shall be installed with a minimum edge
distance of four times the shaft diameter.
INSTALLATION:
1. Built-up Columns: Where hidden in a wall, at contractor's option, wood
columns may be built-up from 2x laminations. Laminations shall be
stitched nailed with staggered 16d@4"OC. Do not splice laminations.
2. At roofs and floors, lay panels with long dimension perpendicular to
supports with short edges staggered.
3. Glue and nail floor sheathing to supports with 8d@6"OC edges and 8d@
12"OC field.
4. Nail roof sheathing to supports with 8d@4"OC edges, 8d@6"OC edges
and 8d@12"OC field, to be determined from analysis.
5. See plans for areas of special blocking and nailing.
6. Nail vertical sheathing to supports with 8d@6"OC edges and 8d@12"OC
field for walls not designated as shear walls.
7. Where shear walls are noted on the plans, the sheathing is used as part
of the lateral load resisting system. See typical details for attachment of
sheathing to supports for wood structural panel shear walls.
8. All panel edges within the extent of the shear wall shall be blocked with
flat 2x4 blocking.
FRAMING TOLERANCES:
1. Layout of walls and partitions: within 1/4" of intended position.
2. Plates and runners: 1/4" in 8' from a straight line.
3. Studs: 1/4" in 8' out of plumb, not cumulative.
4. Face of framing: 1/4" in 8' from a true plane.
COMMON NAIL DIMENSIONSMinimum Length (in)Common Nail (Steel Wire) Minimum Diameter (in)
0.113 2
0.131 2 1/2
0.148 3
0.148 3 1/4
0.162 3 1/2
0.192 4
6d
8d
10d
12d
16d
20d
DOUGLAS FIR-LARCH (DFL)
Select Structural 1,500 psi 1,700 psi 180 psi 1,900 ksi
No1 1,000 psi 1,500 psi 180 psi 1,700 ksi
No2 900 psi 1,350 psi 180 psi 1,600 ksi
Stud 700 psi 850 psi 180 psi 1,400 ksi
Flexural
Stress
DESIGN VALUES FOR DIMENSIONAL LUMBER
Compressive
Stress
Horizontal
Shear Stress
Modulus of
Elasticity
Species &
Grade
Flexural
Stress
DESIGN VALUES FOR MANUFACTURED LUMBER
LAMINATED STRAND LUMBER (LSL)
2x4 and 2x6
Studs - 1.3E
Compressive
Stress
Horiz
Shear
Stress
Modulus of
Elasticity
1,700 psi 1,400 psi 400 psi 1,300 ksi
2,250 psi 1,950 psi 400 psi 1,500 ksi
2,325 psi 1,350 psi 310 psi 1,550ksi
2,600 psi 2,510 psi 285 psi 2,000 ksi
Type - ECompressive
Stress Perp
435 psi
475 psi
800 psi
750 psi
Tensile
Stress
1,075 psi
1,500 psi
1,070 psi
1,555 psi
LAMINATED VENEER LUMBER (LVL)
2x8 Studs -
1.5E
Headers and
Beams - 1.55E
Headers and
Beams - 2.0E
WOOD STRUCTURAL PANEL REQUIREMENTS
Roof over Trusses/Rafters
Minimum ThicknessSupporting Element APA Span Rating
40/20 19/32"
Floors (Sturd-I T&G) 24 OC Single Floor 23/32"
Walls 32/16 15/32"
Shear Walls 32/16 15/32"
REINFORCED MASONRY
GENERAL:
1. All masonry work shall conform to ACI 530.1/ASCE 6/ TMS 602 unless
noted otherwise. Contractor shall keep a copy of these references on site
at all times.
2. Masonry Strength – See Masonry Strength Table
3. Materials – See Masonry Materials Table
TESTING:
1. Owner will engage a qualified Testing Agency, approved by the Architect
and Engineer to perform tests and Special Inspections. Upon completion
of work, Testing Agency shall furnish a certificate of compliance, signed by
the Professional Engineer responsible for management of the Agency. The
Professional Engineer must be registered in the state where the project is
located. Tests and inspections shall be performed in compliance with ACI
530.1/ASCE 6/ TMS 602 and Chapter 17 of the IBC. Inspections include:
proportions of site-prepared mortar, construction of mortar joints,
location of reinforcement and connectors, grout space, grade and size of
reinforcement, proportions of site-prepared grout, grout placement and
curing. Testing includes: Grout strength, mortar strength, and prisms.
2. Masonry grout shall not be placed until reinforcing and connectors have
been inspected by the owner's independent inspection agency and/or the
special inspector.
3. See "Special Inspections and Testing" Table.
SUBMITTALS:
1. Submittals shall conform to ACI 530.1/ASCE 6/ TMS 602. All submittals
shall be reviewed by the Contractor prior to Engineers/Architects review
and shall bear Contractors review stamp. Contractor is responsible for
reviewing submittals for conformance with all contract documents and
coordination with all trades.
2. Submittals for all masonry shall include: Mix designs for grout and mortar,
material certificates for: reinforcing, anchors, ties, and metal accessories,
masonry units, mortar materials, and grout materials.
3. Reinforcing shop drawings shall include placement drawings 1/8"=1'-0”
minimum scale complete with wall elevations. Include special
reinforcement required at openings through masonry structure. Include all
accessories specified and required to support reinforcement.
4. Embed shop drawings shall include placement drawings 1/8”=1’-0”
minimum scale locating all embed plates, anchors, and anchor bolts for
structural and non-structural components attaching to masonry.
Contractor is responsible for coordinating with all trades for determining
the need for embeds and locations. Post installed anchors are not allowed
unless approved by the structural engineer during the shop submittal
process.
REINFORCING AND EMBEDDED ITEMS:
1. Vertical reinforcement shall extend the full height of the wall unless noted
otherwise. Provide vertical reinforcement at all wall corners; end of walls;
each side of openings and at each side of control and expansion joints.
2. Provide bond beams at sill lines, top and bottom edge of openings, top of
walls, floor lines, and roof lines. Bond beams shall be continuous unless
noted otherwise. See typical bond beam detail.
3. Continue reinforcing through construction joints and around corners
unless noted otherwise. Terminate horizontal reinforcement at control
joints except keep bars continuous at floor lines, roof lines, lintels, and top
and bottom of typical openings.
4. Provide standard hooks on bars terminating at a masonry face unless
noted. i.e.: edges of openings, ends of walls, heads, jambs, control joints,
etc.
5. Splice bars with contact laps per the reinforcing splice and development
length table, unless noted otherwise.
6. Vertical reinforcement shall have a minimum clearance of 3/4" from
masonry and shall be supported and fastened together to prevent
displacement.
7. Horizontal joint reinforcing shall be lapped no less than 6" at all splices
including corners and tees where no control joint is used.
8. Dowels from concrete shall be furnished and placed by the concrete
contractor.
9. Welding of reinforcing is prohibited, unless noted otherwise and shall
conform to ASTM A706.
10. Provide embeds (including anchors) for supporting structural and non-
structural elements including but not limited to: hand rails, canopies,
miscellaneous steel, etc.
MASONRY ERECTION:
1. Unless otherwise noted, lay masonry in running bond.
2. Unless noted provide control joints at 30 feet on center.
3. Coordinate blockouts, reveals, holes, openings, and built in items with all
contract documents and trades.
4. Grout lift heights shall follow requirements of TMS 602 Sections 3.5C and
3.5D.Grout lift heights shall follow requirements of TMS 602 Sections 3.5C
and 3.5D.
5. Grout cells solid at: reinforcing, bond beams, inserts, anchors, elevator
guide rails, and 24" below and 12" to each side of steel beam bearing
points.
6. Consolidate grout pours 12" or less in height by mechanical vibration or
puddling not more than five minutes after grouting.
7. Consolidate grout pours exceeding 12" in height by mechanical vibration
not more than five minutes after grouting, and reconsolidate after initial
water loss and settlement has occurred.
8. Grout in masonry beams shall be vibrated as it is placed. Where full depth
grouting is required, the grouting shall extend to the end of the horizontal
reinforcement.
9. Hot weather construction refer to ACI 530.1 section 1.8D.
10. Cold weather construction refer to ACI 530.1 section 1.8C.
Hollow Concrete Masonry Units
Material Standard
ASTM C 90
MASONRY MATERIALS TABLE
ASTM C 145
ASTM C 476Grout
ASTM C 270Mortar
ASTM A615-grade 60Reinforcing
ASTM A706-grade 60Reinforcing Welded
ASTM A951Wire Reinforcing
Solid Concrete Masonry Units
NOTES:
1. Provide lightweight hollow concrete masonry units for general use. Provide normal
weight or solid units where indicated.
2. Mortar for clay masonry shall be type S.
3. Mortar for concrete masonry shall be type S at exterior walls and type N at interior
walls.
4. Hydrated lime required in all mortar.
5. Wire joint reinforcing shall be ladder type.
MASONRY STRENGTH TABLE
Concrete Masonry f'm = 2000 psi
Grout for Concrete Masonry f'g = 1.0*f'm (2000 psi minimum)
Element Specified Compressive Strength
Element Proportions
Fine Grout
Coarse Grout
Mortar Type S
Exterior Walls
Mortar Type N
Interior Walls
(1) Part Portland cement with (1/4) to not more that (1/2) part
hydrated lime and a damp aggregate ratio of not less than (2 1/4) and
not more than (3) times the sum of the separate cementitious
material volumes.
(1) Part Portland cement with (1/2) to not more that (1 1/4) part
hydrated lime, and a damp aggregate ratio of not less than (2 1/4) and
not more than (3) times the sum of the separate cementitious
material volumes.
(1) Part Portland cement with not more that (1/10) part
hydrated lime, and (2 1/4) to (3) parts sand.
(1) Part Portland cement with not more that (1/10) part hydrated
lime, and (2 1/4) to (3) parts sand, and (1) to (2) parts gravel.
GROUT AND MORTAR PROPORTIONING TABLE
NOTES:
1. Grout shall contain a minimum of (7) sacks of cement per cubic yard.
2. Add sufficient water to grout to provide proper consistency without segregation.
12
14
21
39
53
80
NOTES:1. LAPS IN REINFORCING BARS IN REINFORCED MASONRY SHALL HAVE MINIMUM LENGTHS
DEFINED ABOVE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS.2. ALL SPLICES TO BE WIRED TOGETHER.3. SPLICE AND DEVELOPMENT LENGTHS ARE THE SAME VALUE FOR HORIZONTAL AND
VERTICAL BARS.4. F'm MUST BE GREATER THAN OR EQUAL TO 2000 PSI.5. CLEAR COVER FROM FACE OF BLOCK MUST BE GREATER THAN 3.31".
#3
Bar Size
#4
#5
#6
#7
#8
Splice Length (in.)
MASONRY REINFORCING SPLICE LENGTHS
W and WT Sections
Material Standard
ASTM A992 (50 ksi) or
ASTM A572 Gr. 50 (50 ksi)
STEEL MATERIALS DESIGNATION
ASTM A36 (36ksi)M, S, C, MC, L, MT, ST Sections
ASTM A572 Gr. 50 (50ksi)HP Sections
ASTM A53 Gr. B (35ksi)Pipe
ASTM A500 Gr. C (50 ksi)Rectangular HSS
Round HSS
Plates, Bars, and threaded rod
- typical
- when noted as 50ksi
ASTM F1554 Gr. 55 w/ Supplement S1Anchor Rods
ASTM F3125 Grade A325 or F1852
ASTM A490 or ASTM F2280
ASTM F3125 Grade A490 or F2280
Bolts
- typical (Group A)
- where noted as Group B
- where indicated as A307
ASTM A563, Heavy HexNuts
ASTM A500 Gr. C (46 ksi)
ASTM A36 (36ksi)
ASTM A572 Gr. 50 (50ksi)
ASTM F436, except plate washers to be
ASTM A36
Washers
ASTM F959Direct-Tension-Indicator Washers
ASTM A108/A29Headed Stud Anchors
E70, 70ksiWeld Electrodes
ASTM A36All Thread Rod and Threaded Studs, UNO
ASTM A29 or A572High Strength Threaded Studs
Standard
3/4"ø A325 Bolt
BOLT GRADES Bolt Size, Joint Type and
Designation on Drawings
3/4"ø Bolt, ASTM F3125 Grade A325 or
F1852
3/4"ø A325 SC-A Bolt
3/4"ø Bolt, ASTM F3125 Grade A325 or
F1852 with Class A Faying Surface and
Bolt Tightened to Slip Critical
NOTES:
1. Reference plan, details and connection tables for bolt size and joint type.
2. All bolts are snug tight, unless indicated on plan or details as slip critical or fully
tensioned.
3. Holes may be short slotted transverse to applied load, unless plans, details or
connection tables indicate a standard or oversize hole.
4. Where bolts are indicated as slip critical or fully tensioned, pretension bolt as defined
by AISC 360, Table J.1
5. Class A faying surfaces are unprimed surfaces or hot dip galvanized surfaces with
hand wire brush roughening, as defined by AISC 360.
6. Class B faying surfaces are blast cleaned surfaces as defined by AISC 360.
7. Bolted connections to follow all requirements indicated in the Specification for
Structural Joints Using High Strength Bolts (RCSC)
1"ø A490 Bolt1"ø Bolt, ASTM F3125 Grade A490 or
F2280
1"ø Bolt, ASTM F3125 Grade A490 or
F2280 with Class A Faying Surface and
Bolt Tightened to Slip Critical
1/2"ø or 3/4"ø A307 Bolt1/2"ø or 3/4"ø Bolt, ASTM A307 Gr. A
1"ø A490 SC-A Bolt
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:0
0 A
M
S002GENERAL NOTES
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
A Permit Resubmittal 08/23/2019
A
PROGRESS PRINT 09.04.2019
LOAD AREA PATTERNSELF
WEIGHT (psf)
LIVE LOAD REDUCTION DESCRIPTION OF LOAD NOTES
SUPERIMPOSED LOADS
DEAD LOAD (psf)
LIVE LOAD (psf)
SNOW LOAD (psf)
TYP PUBLIC AREA FLOOR2015 100 -- NO
DRIFTING SNOW LOAD DIAGRAMNOTES:
1. DRIFTING SNOW LOADS ARE DEFINED BY DIAGRAM TO THE RIGHT.2. ROOF LIVE AND SNOW LOADS DO NOT ACT CONCURRENTLY.3. STAIRS TO BE DESIGNED BY STAIR MANUFACTURER. SELF WEIGHT AND
SUPERIMPOSED DEAD LOADS TO BE DETERMINED BY STAIR MANUFACTURER.4. VERTICAL WIND LOADS ARE MWFRS LOADS AND HAVE NOT BEEN REDUCED BY
DEAD LOADS. NEGATIVE LOADS ARE UPLIFT. RE: STRUCTURAL DESIGN CRITERIA TABLE FOR COMPONENTS AND CLADDING DESIGN CRITERIA.
5. WHERE THE BUILDING CODE REQUIRES PARTITION LOADS TO BE CONSIDERED AS LIVE LOADS, THEY ARE INCLUDED IN THE LIVE LOADS SHOWN.
6. WHERE PREMANUFACTURED ROOF TRUSSES OCCUR, APPLY LOADS AS FOLLOWS:CASE #1: APPLY TABULATED LOADS TO TOP CHORDS.CASE #2: APPLY TABULATED LOADS TO TOP CHORDS W/ 8 PSF DEAD
LOAD REDUCTION. APPLY 8 PSF DEAD LOAD TO BOTTOM CHORD. APPLY 10 PSF LIVE LOAD TO BOTTOM CHORD.
Pd
Pf
Ld
--
LOAD KEY LEGEND
1
TYP RESIDENTIAL AREA FLOOR20 40 -- YES --
VERT WIND LOAD (psf)
--
--
5
2
3
15
SEE NOTES 1,2,4,5ROOF8 20 30 NO--15
SNOW DRIFT LOAD KEY LEGEND
PATTERNDRIFT
MAGNITUDE, Pd (PSF)
DRIFT LENGTH, Ld
(FT)DESCRIPTION OF LOAD
1
2
3
4
6
7
9
10
29
33
42
48
SCREEN WALL SNOW DRIFT
5
4
12" PT SLAB, PUBLIC AREA FLOOR25150 100 -- NO
12" PT SLAB, RESIDENTIAL AREA FLOOR25 40 -- YES
--
--150 --
--
CANOPY5 20 30 NO--106 --
A
1 2 4 6
6
7
7
A
B
H
4
4 4
2 1
3
35
5
C
E
I
A.1
A.5
C.1
C.8
D.8
E.8
13 1110
8
6
6
6
6
6
6
66
6
6
66
1 2 4 6
6
7
7
A
B
4
4
4
3
4
3
3 5
5
C
E
I
A.1
A.5
C.1
C.8
D.8
E.8
13 1110
8
1 2 4 6
6
7
7
A
B 5
5
5
24
4
2
2
11
41
4
1
3 3 1
33
11
13
11
11
11
3
5
C
E
I
A.1
A.5
C.1
C.8
D.8
E.8
13 1110
8
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:0
3 A
M
S003LOAD KEYS
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
1" = 20'-0"1 2ND FLOOR LOAD KEY
1" = 20'-0"2 3RD FLOOR LOAD KEY
1" = 20'-0"3 ROOF LOAD KEY
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
A Permit Resubmittal 08/23/2019
A
A
A
PROGRESS PRINT 09.04.2019
T
T/3
1 1/2"CONTINUOUS KEYWAY
MAIN REINF
A. TYPICAL SLAB CONSTRUCTION JOINT
DOWELS"T" DOWELS
6" #4x4'-0"@14"
8" #4x4'-0"@12"
9" #4x4'-0"@11"
10" #4x4'-0"@10"
11" #4x4'-0"@9"
12" #5x5'-0"@12"
H
H/3
H/3
H/3
1 1/2"
1'-0"
ADDITIONAL STIRRUPS @3"OC
MAIN REINF
ADD (2) #6x5'-0" FOR EVERY 220 SQ IN OF BEAM CROSS SECTIONAL AREA. PLACE (2) LAYERS MIN WITHIN MIDDLE THIRD OF BEAM DEPTH AS SHOWN. MAINTAIN 4" MIN REINF SPACING.
2"
B. TYPICAL GRADE BEAM AND BEAM CONSTRUCTION JOINT
EQ EQ
6" TYP
6"
4"4"
6"6" TYP
2'-6" 2'-6"
6" TYP
6"
NOTES:1. LOCATE CONSTRUCTION JOINTS AT POINTS OF MIN
SHEAR GENERALLY IN THE MIDDLE THIRD OF THE SPAN.2. ALL REINFORCING IS CONTINUOUS THROUGH THE JOINT.
SECTION VIEW
HOOK BOTTOM REINF
TYP SLAB REINF
HOOK TOP REINF,IF NO REINF ADD #5x6'-0"@16" W/ STD HOOK UNO ON PLAN
2'-0" UNO
HOOK BOTTOM REINF
DRE:PLAN
RE: P
LAN
DTYP
CLASS
B S
PLICE
STEP
STEP
STEP
SLAB SOFFIT STEP
SLAB STEP
EXTEND BOT REINF INTO SLAB
HOOK TOP REINF AT EXTERIOR CORNERS
(STEP EDGE)
EXTEND TOP REINF INTO SLAB
HOOK BOT REINF AT INTERIOR CORNERS(SOFFIT STEP)
TYP
CLASS B SPLICE
STEP LESS THAN OR EQUAL TO D
ADD #5 CONT AT STEP
HOOK TOP REINF
ADD #5 CONT AT STEP
2'-0" UNO
CLASS B LAP
SECTION VIEWSTEP LESS THAN OR EQUAL TO D/2
TYP SLAB REINF
PLAN VIEW
NOTES:1. LOCATION OF CONSTRUCTION JOINTS IN WALLS: SUPPORTED ON CONTINUOUS
FOOTINGS AT CONTRACTOR OPTION.2. LOCATE CONSTRUCTION JOINTS IN WALLS ACTING AS GRADE BEAMS AT POINT OF
MINIMUM SHEAR, GENERALLY AT MIDDLE THIRD OF SPANS.
THICKNES
S
ALL REINF CONT
B LAP SPLICEOR
WALL REINF
.
FIRST POUR
CONST OR CONTROL JOINTS, RE: SOG JOINTING
BOND BREAK MATERIAL AROUND BLOCK OUT
#4 EA CORNER
CIP OR PC COL
±2"
T/SOG
PROVIDE ACCESSORIES TO SUPPORT REINFORCEMENT, REINF CHAIRED AT MID-HEIGHT
VAPOR BARRIER/INSULATION, RE: NOTE
COMPACTED BASE, RE: NOTE
SUBGRADE, RE: NOTE
RE: P
LAN
REINFORCING, RE: PLAN
NOTES:1. RE: ARCH FOR VAPOR BARRIER AND INSULATION REQUIREMENTS. UNO RE: ARCH: PROVIDE
VAPOR BARRIER BELOW SLABS WITH FLOOR FINISHES SUSCEPTIBLE TO MOISTURE.2. SOG SHALL BEAR ON SUITABLE SUBGRADE MATERIAL AS SPECIFIED BY THE GEOTECHNICAL
ENGINEER & GEOTECHNICAL REPORT.3. PROVIDE MIN 4" FREE DRAINAGE COMPACTED BASE TYPICAL UNO BY GEOTECHNICAL ENGINEER
& GEOTECHNICAL REPORT.
T/SOG
T/SOG
SAWCUT OR TOOLED CONTROL JOINT, CAULK RE: ARCH
NOTES:1. STOP REINF AT EACH SIDE OF CONSTRUCTION JOINT2. PROVIDE CONTROL JOINTS AT 15 FT OC EACH WAY MAXIMUM SPACING,
UNO. CONSTRUCTION JOINTS CAN REPLACE CONTROL JOINTS.3. UNO AT GARAGES, REINFORCING PASSING THROUGH CONSTRUCTION JOINTS
SHALL BE EPOXY COATED.
NOTES:1. SAWCUT CONTROL JOINT WITHIN 8 HOURS (MAX) OF PLACEMENT OR
USE TOOLED JOINT DURING FINISHING (CONTRACTOR'S OPTION)2. PROVIDE CONTROL JOINTS AT 15 FT OC EACH WAY MAXIMUM SPACING,
UNO. CONSTRUCTION JOINTS CAN REPLACE CONTROL JOINTS.
1" M
IN
TYPICAL SOG CONTROL JOINT
TYPICAL SOG CONSTRUCTION JOINT
JOINT
#3x3'-0"@18"OC THRU JOINT, CENTERED IN DEPTH
T/SOG
T/SOG
STEP MORE THAN 8" TO 24" MAX
STEP = 8" OR LESS
#4@12" HORIZ WHEN STEP EXCEEDS 18"
OPTIONAL CONST JOINT
#5 CONT T&B
#4@16"
SOG REINF
#4 CONTINUOUS
1'-6"
1'-6"
.
STEP
RE: P
LAN
T/SOG
T/SOG
2" CLEAR
2" CLEAR
STEP
RE: P
LAN
SECTION(2) #5 CONT
8" M
IN
CENTER
1'-4"1
1
T/SOG
PLAN
THICKENED SLAB
1'-0"
STAIRS AND CONNECTIONS TO STRUCTURE BY STAIR SUPPLIER
STAIR STRINGERS RE: ARCH DWGS
.
T/SOG
DOWELS: MATCH VERT BARS, FURNISHED AND INSTALLED BY CONC CONTRACTOR
RE: ARCH DWGS FOR t AND WALL LOCATIONS
(2) #5 CONT "A"
LAPS
MIN
1'-0"
CENTER BELOW WALL
2t OR 18" MIN, USE GREATER
RE: P
LAN
t
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:0
4 A
M
S010TYPICAL DETAILS -
CONCRETE
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS1 TYPICAL SLAB AND BEAM CONSTRUCTION JOINT
NTS5 TYPICAL STRUCTURAL SLAB STEPS
NTS2
TYPICAL WALL CONSTRUCTION JOINTSINGLE MAT OF REINFORCING
NTS3
TYPICAL SLAB-ON-GRADE BLOCKOUT AT CONCRETE COLUMNS
NTS4 TYPICAL SLAB-ON-GRADE
NTS6 TYPICAL SLAB-ON-GRADE JOINTING
NTS9 TYPICAL SLAB-ON-GRADE STEPS
NTS8
TYPICAL THICKENED SLAB-ON-GRADE AT STAIR
NTS7
TYPICAL THICKENED SLAB-ON-GRADE AT MASONRY
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
A AA A
AA
AA
STANDARD HOOK
INTERSECTIONSEND OF WALL
NOTES:1. DOWELS AND CORNER BARS MATCH HORIZONTAL REINF EXCEPT USE
#5 DOWELS & CORNER BARS FOR HORIZONTAL BARS #6 AND LARGER2. SEQUENCING OF VERTICAL AND HORIZONTAL REINFORCING PER
DETAILS CUT ON PLAN, UNO
OBTUSE ANGLE CORNERSRIGHT ANGLE CORNERS
CLASS B SPLICE, TYP
RE: P
LAN
CLASS B SPLICE, TYP
CLASS
B S
PLICE, TYP
STANDARD 180 DEG HOOK
CLASS
B S
PLICE, TYP
CLASS
B S
PLICE, TYP
STANDARD HOOK
INTERSECTIONSEND OF WALL
TYP
CLASS
B S
PLICE
"U" BAR
NOTES:1. DOWELS AND CORNER BARS MATCH HORIZONTAL REINF EXCEPT USE
#5 DOWELS & CORNER BARS FOR HORIZONTAL BARS #6 AND LARGER2. SEQUENCING OF VERTICAL AND HORIZONTAL REINFORCING PER
DETAILS CUT ON PLAN, UNO
OBTUSE ANGLE CORNERSRIGHT ANGLE CORNERS
CLASS B SPLICE, TYP
RE: P
LAN
CLASS B SPLICE, TYP
CLASS B SPLICE, TYP
STANDARD HOOK
LENGTH, TYP
TENSION DOWEL
EMBEDMENT
4'-0" MAX
"U" BARS TO MATCH SIZE OF WALL REINFORCEMENT
WHERE NOT POSSIBLE TO MAINTAIN CLASS B PAST OPENING, HOOK REINF
NOTES:1. RE: WALL ELEVATIONS OR PLANS FOR REINFORCEMENT AT LARGER OPENINGS.2. CLUSTERS OF SMALL HOLES WHOSE OVERALL MEASUREMENT EXCEEDS 1'-0"
SHOULD BE REINFORCED AS ONE OPENING.3. WALLS CAN SPAN IN EITHER DIRECTION.4. FOR SINGLE MESH WALLS CENTER REINF IN WALL & HOOK BARS AROUND
OPENING W/ 180 DEG HOOK.
ADD BARS TO WALL OPENINGS
AS REQD
ADD 1/2 OF PARALLEL INTERRUPTED BARS AT EACH SIDE OF OPENING BUT NOT
LESS THAN (1)#5 EF
SECTION A-A
OPENING >12"(1)#5x4'-0" EF DIAGONAL BARS AT EACH CORNER
CLASS B TYP
INTERRUPTED BAR
NOTE 36" TYP
Z3'-0"
CLASS B SPLICEVERT REINF, LOCATE AT STEP
CLR3"
DRILLED PIER
HOOK REINF AT STEP
EXTEND REINF PAST STEP AND SPLICE W/ ADJACENT REINF
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:0
5 A
M
S011TYPICAL DETAILS -
CONCRETE
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS1
TYPICAL WALL AND GRADE BEAM CORNER REINFORCINGSINGLE MAT OF REINFORCING
NTS2
TYPICAL WALL AND GRADE BEAM CORNER REINFORCINGDOUBLE MAT OF REINFORCING
NTS4 TYPICAL WALL OPENING REINFORCING
NTS3 TYPICAL GRADE BEAM BOTTOM STEP
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
4"
4"8"
1 1/2"
1 1/2"
4"8"
1 1/2"
1 1/2"
4"8"
1 1/2"
1 1/2"
4TH PART
TYP (3) PART COL
STAGGERED 10d OR 16d COMMON WIRE NAILS @4"OC, ALT SIDES
(3) PART COLSTAGGERED 16d COMMON WIRE NAILS @4"OC,ALT SIDES
(4, OR 5) PART COL4TH PART - STAGGERED 16d COMMON WIRE NAILS @4"OC
4TH PART
TYP (3) PART COL
(2) PART COL
TYPICAL STUDS, RE: PLAN FOR SPACING ATTACH SHEATHING W/ FIELD NAILING OR SCREWS
(3), (4), OR (5) PART STUD PACK
PLYWOOD, OSB OR GYPSUM WALL SHEATHING
NAILS OR SCREWS AT 8"OC MAX AT BOUNDARY AND MIDDLE LAMINATIONS AT (5) PLY STUD PACK
NAILS OR SCREWS @8"OC MAX AT BOUNDARY
LAMINATIONS OF STUD PACK
TYPICAL WALL SHEATHING TO STUD PACK ATTACHMENT
1 1/4"x16GA STRAP W/ (13) 8d NAILS AND 14" EACH SIDE OF JOINT
RIM BOARD: MATCH JOIST SIZE
ELEVATION
NOTES:1. STAGGER SPLICES 10'-0" (MIN).2. WHERE PLAN CALLS FOR DOUBLE MEMBER USE SPLICE FOR BOTH.3. ALLOWABLE TENSION THROUGH THE SPLICE IS 1705 LB.
16d@12" STAGGERED (AT DOUBLE MEMBERS ONLY)
NAIL W/ (8) 16d ON EACH SIDE OF EACH BREAK IN TOP PLATE,
STAGGER TO AVOID SPLITTING
CENTER LOWER SPLICE OVER STUD
TOP VIEW
ELEVATIONNOTES: 1. NAILING APPLIES AT SPLICE OF BOTH UPPER AND LOWER TOP
PLATES.2. ALLOWABLE TENSION ACROSS SPLICE IS 3610 LB FOR DFL.3. ALLOWABLE TENSION ACROSS SPLICE IS 3124 LB FOR HF/SPF.4. TYPICAL NAILING AWAY FROM SPLICE IS 16d@16"OC.5. 4'-0" MINIMUM SPACING BETWEEN SPLICES.6. CODE REFERENCE: IBC 2015, TABLE 2304.10.1 & 2308.5.3.2
1. 1"x6" sheathing to each bearing or joist; face nail
2. 1"x8" and wider sheathing to each bearing; face nail
3. 2" subfloor to joist, girder, or blocking; blind and face nail
6. Bottom plate to joist or blocking; face nail
7. Top or bottom plate to stud; end nail
8. Stud to top or bottom plate
9. Stud to stud; face nail
10. Top plate to top plate; face nail
11. Top plate to top plate at end joints; each side of end joint, face nail (min 24" lap splice length each side of end joint)
14. Built-up header (2" to 2"); face nail
16. Ceiling joists to plate; toenail
15. Continuous header to stud; toenail
17. Ceiling joists not attached to parallel rafter, laps over partitions; face nail
18. Ceiling joists attached to parallel rafter
19. Joist at all bearings; toenail
23. 1" brace to each stud and plate; face nail
24. Built-up corner studs
25. Built-up girder and beams
26. 2" planks; face nail
27. Bridging to joist
28. Plywood Sheathing
(2) 8d
(3) 8d
(2) 16d
16d@16"OC
(2) 16d
(4) 8d toenail or (2) 16d end nail
16d@24"OC
16d@16"OC
(8) 16d
16d@16"OC each face
(3) 8d
(4) 8d
(3) 16d
RE: IBC Table 2308.7.3.1
(3) 8d
(2) 8d
16d@24"OC
20d@32"OC at top and bottom and staggered (2) 20d at ends and
at each splice
(2) 16d at each bearing
(2) 8d
At shear walls - RE: "Typical Wood Shear Walls -Nailing Schedule and Details"
Other walls - RE: general or plan notes
Blocking between joists and rafters - To joists or rafters - Toenails each side, each end
THIS DETAIL CONFORMS TO ALL IBC 2015 (AND OLDER) REQUIREMENTS
TYPICAL MINIMUM NAILING REQUIREMENTS
CONNECTION COMMON NAILS ALTERNATE OPTION
--
--
--
(3) 3"x0.131"T
(4) 3"x0.131"T toenail or (3) 3"x0.131"T end nail
3"x0.131"T@12"OC
3"x0.131"T@16"OC
3"x0.131"T@12"OC
--
--
(3) 3"x0.131"T
(4) 3"x0.131"T
(3) 3"x0.131"T
21. Rafter or roof truss to top plate; toenail (3) 10d (4) 3"x0.131"T
22. Roof rafters to ridge valley or hip rafters, or roof rafter to 2" ridge beam
(2) 16d end nail or(3) 10d toenail
(3) 3"x0.131"T end nail or (4) 3"x0.131"T toenail
(2) 3"x0.131"T
3"x0.131"T@12"OC
3"x0.131"T@24"OC at top and bottom and staggered (3) 3"x0.131"T at ends and at each splice
Manufactured Lumber: As required by manufacturer but not less than nailing for Dimensional Lumber
--
(2) 3"x0.131"T
Blocking between studs, each end (2) 16d end nail or(2) 10d toenail
(3) 3"x0.131"T end nail or (2) 3"x0.131"T toenail
12. Top plate laps at corners and intersections; face nail (2) 16d
(12) 3"x0.131"T
(3) 3"x0.131"T
Dimensional Lumber:
4. Blocking between ceiling joists, rafters or trusses to top plate or other framing below; each end, toenail
(3) 8d (3) 3"x0.131"T
5. Blocking between rafters or truss to rafter or truss (2) 8d toenail ea end or (2) 16d end nail
(2) 3"x0.131"T toenail ea end or (3) 3"x0.131"T end nail
13. Rim joist or blocking to top plate, sill or other framing below; toenail 8d@6"OC 3"x0.131"T@6"OC
20. Joist to rim joist; end nail (3) 16d (4) 3"x0.131"T
D
3xD MIN
EQEQ
2" MIN
D/3 M
AX
D
3xD
MIN
D/10 M
AX D/5 MAX
NEATLY BORED HOLE
D/3 MAX
D
6" MAX(12) 16d
D/2 M
AX
D
(6) 16d
1 1/2" x 16GA STRAP EACH PLATE EACH SIDE OF NOTCH/HOLE
1 1/4" x 12GA STRAP EACH PLATE
A. SECTION - HOLES IN WOOD STUDS
B. PLAN - NOTCHES IN WOOD PLATES NOT IN SHEAR WALLS
C. PLAN - NOTCHES IN WOOD PLATES AT SHEAR WALLS
D. SECTION -NOTCHES AND HOLES IN WOOD JOISTS AND RAFTERS
(NOTCHES NOT PERMITTED IN STUDS)
(APPLIES TO DIMENSIONAL LUMBER ONLY. FOR MANUFACTURED LUMBER OR WOOD I-JOIST RE: MANUFACTURER OR CONTACT ENGINEER)
PLATE PENETRATION
FULL HEIGHT WALL PERPENDICULAR TO FRAMING
FULL HEIGHT WALLPARALLEL TO FRAMING
8d@12" FIELD NAILING (MIN)SHEATHING
SIMPSON DTC @48"OC, MAX, LEAVE 1/2" GAP
SHEATHING 8d@12" FIELD NAILING (MIN) ADD NAILS AS REQUIRED
(2) 16d TOENAILSCEILING JOIST, RAFTER, OR ROOF TRUSS
SIMPSON DTC @48"OC, MAX, LEAVE 1/2" GAP
2x NON-LOADING BEARING WALL, RE: ARCH
CEILING JOIST, RAFTER, OR ROOF TRUSS
2x NON-LOADING BEARING WALL, RE: ARCH
JOIST PERPENDICULAR TO WALL
JOIST PARALLEL TO WALL
FLOOR FRAMING
(2) 16d NAILS INTO BLOCKING
2x NON-LOADING BEARING WALL, RE: ARCH
SOLID BLOCKING @16"OC ALIGN WITH WALL STUDS
NOTE: CONTRACTOR MAY ELIMINATE BLOCKING BY DOUBLING JOISTS DIRECTLY BELOW WALL, DO NOT EXCEED JOIST SPACING SHOWN ON PLAN
BOTTOM PLATE
(3) 16d NAILS EA SIDE
FLOOR FRAMING
(2) 16d NAILS INTO EACH JOIST
2x NON-LOADING BEARING WALL, RE: ARCH
BOTTOM PLATE
SPAN DIMENSIONEDDOUGLAS-FIR LSL ALTERNATES LVL ALTERNATES GLULAM ALTERNATES
3'-0"
4'-0"
5'-0"
6'-0"
7'-0"
8'-0"
9'-0"
10'-0"
(3) 2x6
(3) 2x8
(3) 2x10
(3) 2x12
N/A
N/A
N/A
N/A
(2) 1 3/4"x5 1/2"
(2) 1 3/4"x5 1/2"
(2) 1 3/4"x7 1/4"
(3) 1 3/4"x7 1/4"
(3) 1 3/4"x9 1/4"
(3) 1 3/4"x9 1/4"
(3) 1 3/4"x11 1/4"
(3) 1 3/4"x11 7/8"
(2) 1 3/4"x5 1/2"
(2) 1 3/4"x5 1/2"
(3) 1 3/4"x5 1/2"
(3) 1 3/4"x7 1/4"
(2) 1 3/4"x9 1/4"
(3) 1 3/4"x9 1/4"
(2) 1 3/4"x11 1/4"
(3) 1 3/4"x11 1/4"
3 1/2"x6"
3 1/2"x6"
3 1/2"x7 1/2"
3 1/2"x9"
3 1/2"x9"
3 1/2"x10 1/2"
3 1/2"x11 7/8"
3 1/2"x13 1/2"
1
SPAN DIMENSIONED LUMBERDOUGLAS-FIR
LSL ALTERNATES LVL ALTERNATES GLULAM ALTERNATES
3'-0"
4'-0"
5'-0"
6'-0"
7'-0"
8'-0"
9'-0"
10'-0"
(2) 2x4
(3) 2x4
(2) 2x6
(3) 2x6
(2) 2x8
(3) 2x8
(3) 2x10
(3) 2x10
(2) 1 3/4"x5 1/2"
(2) 1 3/4"x5 1/2"
(2) 1 3/4"x5 1/2"
(2) 1 3/4"x5 1/2"
(3) 1 3/4"x5 1/2"
(2) 1 3/4"x7 1/4"
(3) 1 3/4"x7 1/4"
(2) 1 3/4"x9 1/2"
(2) 1 3/4"x5 1/2"
(2) 1 3/4"x5 1/2"
(2) 1 3/4"x5 1/2"
(2) 1 3/4"x5 1/2"
(3) 1 3/4"x5 1/2"
(2) 1 3/4"x7 1/4"
(2) 1 3/4"x7 1/4"
(3) 1 3/4"x7 1/4"
3 1/2"x6"
3 1/2"x6"
3 1/2"x6"
3 1/2"x6"
3 1/2"x6"
3 1/2"x7 1/2"
3 1/2"x7 1/2"
3 1/2"x7 1/2"
HEADER CONNECTION
HEADER CONNECTION
2x10d
2x10d
2x10d
2x10d
2x10d
2x10d
2x10d
2x10d
4x10d
4x10d
4x10d
6x10d
6x10d
6x10d
8x10d
8x10d
NO OF BEARING STUDS
EACH END
1
1
1
1
1
1
1
1
NO OF BEARING STUDS
EACH END
1
2
2
2
2
3
3
RECOMMENDED HEADERS IN INTERIOR NON-LOAD BEARING WALLS
HEADERS IN LOAD BEARING WALLS
ELEVATION
BEARING STUDS EACH SIDE, RE: TABLE
HEADER
HEADER CONNECTION, RE: TABLE
NOTES:1. THIS TABLE APPLIES TO HEADERS WHICH ARE NOT EXPLICITLY CALLED OUT ON PLAN WITH SPANS OF 10'-0" OR LESS2. HEADERS IN LOAD BEARING WALLS DESIGNED FOR 1500 PLF DEAD + LIVE LOAD.3. HEADERS IN NON-LOAD BEARING WALLS DESIGNED FOR 400 PLF DEAD + LIVE LOAD.4. DIMENSIONED LUMBER HEADERS TO BE DOUGLAS-FIR No2.5. LVL = LAMINATED VENEER LUMBER: Fb = 2600 PSI, E = 2000 KSI6. LSL = LAMINATED STRAND LUMBER: Fb = 2325 PSI, E = 1550 KSI7. GLULAM GRADE IS 24F-V4 DF8. LIVE LOAD DEFLECTION CRITERIA IS L/3609. HEADERS SUPPORTING POINT LOADS FROM BEAMS OR COLUMNS SHOULD NOT BE SIZED FROM THIS TABLE. NOTIFY STRUCTURAL ENGINEER.10. RE: ARCH FOR LOCATIONS OF NON-LOAD BEARING WALLS.
HEIGHT = 12'-0" (MAX
)
SPAN
KING (WIND) STUDS EACH SIDE. MINIMUM NUMBER OF KING STUDS EACH SIDE IS EQUAL TO HALF THE NUMBER OF STUDS INTERRUPTED BY HEADER PLUS ONE, (2) MIN
10
(2) ROWS OF SDS25312@6"OC, TYP
(2) 1 3/4" LVLOR
(2) 1 1/2" 2xw = 1360 PLF
(3) 1 3/4" LVLOR
(3) 1 1/2" 2xw = 510 PLF
2" TYP
NOTES:1. ALL MULTIPLE WOOD MEMBERS MUST BE FASTENED TOGETHER TO ACT AS A SINGLE UNIT.2. LAMINATIONS SHALL BE CONTINUOUSLY GLUED WITH EXTERIOR GLUE.3. LAMINATIONS SHALL BE DRY (LESS THAN 16% MOISTURE CONTENT) WHEN GLUED. DO NOT SPLICE LAMINATIONS4. WHERE FASTENERS TO BE INSTALLED ON BOTH SIDES, STAGGER BY 1/2 THE REQUIRED CONNECTOR SPACING.5. PSL MATERIAL OF EQUAL CROSS-SECTIONAL DIMENSIONS MAY BE SUBSTITUTED FOR BUILT-UP LVL BEAMS.6. 7" WIDE BEAMS SHOULD BE SIDE-LOADED ONLY WHEN LOADS ARE APPLIED TO BOTH SIDES OF THE MEMBERS
(TO MINIMIZE ROTATION).7. w = MAXIMUM UNIFORM LOAD APPLIED TO EITHER OUTSIDE MEMBER.
(2) ROWS OF SDS25312@12"OC, TYP
(2) ROWS OF SDS25312@12"OC, TYP
(2) 1 3/4" LVLOR
(2) 1 1/2" 2xw = 680 PLF
(2) 1 3/4" LVLOR
(2) 1 1/2" 2xw = 1020 PLF
(2) ROWS OF SDS25312@8"OC, TYP
2" TYP
2" TYP
2" TYP
(3) 1 3/4" LVLOR
(3) 1 1/2" 2xw = 1020 PLF
2" TYP
(2) ROWS OF SDS25312@6"OC, TYP
(3) 1 3/4" LVLOR
(3) 1 1/2" 2xw = 765 PLF
2" TYP
(2) ROWS OF SDS25312@8"OC, TYPKL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:0
7 A
M
S012TYPICAL DETAILS - WOOD
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS3 TYPICAL STUD PACK NAILING
NTS4 TYPICAL RIM BOARD SPLICE
NTS8 TYPICAL TOP PLATE SPLICE
NTS1 TYPICAL MINIMUM NAILING REQUIREMENTS
NTS2
TYPICAL REQUIREMENTS FOR HOLESAND NOTCHES IN WOOD MEMBERS
NTS6
TYPICAL NON-BEARING PARTITIONWALL TOP SUPPORT
NTS7
TYPICAL NON-BEARING PARTITIONWALL BASE SUPPORT
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
A Permit Resubmittal 08/23/2019
NTS9 TYPICAL WOOD HEADER TABLE
A
NTS5 BUILT-UP WOOD BEAM DETAIL
A
PROGRESS PRINT 09.04.2019
OPEN
ING
16" MAX
PLAN
RE:
CROSS WIRE
CROSS WIRE
COVER TYP5/8" MIN
CMU
VERT REINF, TYP
LADDER TYPE JOINT REINF MIN 9GA
MIN LAP
6"
3/8"
BACKER ROD AND SEALANT
PROVIDE HEAD JOINT AND RAKE 3/4" AT CONT REBAR ONLY
STOP HORIZONTAL REINFORCEMENT AT CONTROL JOINTS AS SHOWN EXCEPT KEEP BARS CONTINUOUS AT:-FLOORS-ROOFS-LINTELS-TOP AND BOTTOM OF TYPICAL OPENINGS
STOP ALL LONGITUDINAL WIRES AT ALL CJS
EXTERIOR FACE
HOOKED END MAY BE MADE W/ 3'-0" LAPPED BAR
INTERIOR FACE
VERTICAL WALL REINF
PROVIDE HEAD JOINT AND RAKE 1/4" AT CONT REBAR ONLY
CORNER LAP BAR TO MATCH HORIZ REINFORCEMENT
3'-0"
3'-0"
MINALTERNATE DIRECTION OF LAP BAR EVERY OTHER BOND BEAM
REMOVE FACE SHELL AT LEAST 1/2 UNIT HEIGHT
VERT REINFORCEMENT
BOND BEAM BLOCK
HORIZ BOND BEAM REINFORCEMENT
INTERSECTIONS PLAN VIEW
CORNER LAP BAR TO MATCH HORIZ REINFORCEMENT
3'-0"
3'-0"
MIN
VERT REINFORCEMENT
REMOVE FACE SHELL AT LEAST 1/2 UNIT HEIGHT
HORIZ BOND BEAM
REINFORCEMENT
BOND BEAM BLOCK
NOTE:ALL CORNERS SHOULD HAVE JOINT REINFORCEMENT @16"OC PER TYP JOINT REINFORCEMENT DETAIL
RIGHT ANGLE AND ACUTE ANGLE CORNERSPLAN VIEW
WALL REINFORCEMENTSECTION VIEW
SCREEN WHERE HOLLOW BELOW
REINFORCEMENT
VERT BARS, GROUT CELLS AT REBAR
GROUT COURSE SOLID
END OF WALLPLAN VIEW
180 DEGREE HOOKED END, BAR MAY BE ROTATED TO FIT WITHIN WALL
VERTICAL WALL REINF IN END CELL
3'-0" M
IN LAP
USE WIRE REBAR POSITIONERS TO SECURE VERTICAL BARS AT TOP, BOTTOM, AND INTERVALS NOT TO EXCEED 200 BAR DIAMETERS
PARTIALLY OR FULLY GROUTED UNITS
LINTEL BLOCK TYP(MATCH WALL THICKNESS)
MASONRY OPENING WIDTH
REINFORCED CMU LINTEL TABLE
NOMINAL BLOCK WIDTH
TO 4'-0"
TO 8'-0"
TO 10'-0"
MINIMUM BEARING EACH END
8" DEEP W/ (1) #4
16" DEEP W/ (1) #5
16" DEEP W/ (1) #6
8"
8"
8"
8" DEEP W/ (2) #4
16" DEEP W/ (2) #4
16" DEEP W/ (2) #5
8" DEEP W/ (2) #4
16" DEEP W/ (2) #4
16" DEEP W/ (2) #5
8" DEEP W/ (2) #4
16" DEEP W/ (2) #5
16" DEEP W/ (2) #6
6" 8" 10" 12"
FULL DEPTH OF BOND BEAM TO BE GROUTED SOLID. RE: "TYP CMU REINF AT OPENINGS" DETAIL FOR
VERTICAL REBAR AT EA SIDE OF OPENINGS
8"
1'-4"
T/TRUSS
MASONRY SUPPORT AT WOOD TRUSS
GROUT CMU CELLS AT BOLT LOCATIONS
5/8"T THREADED ROD W/ HILTI HIT-HY70 W/ 5 5/8" MIN EMBEDMENT IN BOTTOM OF
3/4"Tx2" VERT LONG SLOTTED HOLE
L8x6x7/16x1'-0" LLV FASTEN TO EACH TRUSS W/ (2) SIMPSON
SDS25300
4"
TRUSS, RE: PLAN FOR ORIENTATION
MAX WALL HEIGHT = XX'-X"
T/FLOOROR ROOF
CORNER, WALL END, OR MOVEMENT JOINT
MAX
8"
16" MAX
(2) #4
40 BAR DIA OR 2'-0" WHICHEVER IS GREATER, TYP
TYPICAL HORIZONTAL REINFORCEMENT PER PLAN OR
OTHER DETAILS, (1) #4 MIN
T/FLOOR
TYPICAL VERTICAL REINFORCEMENT PER PLAN OR
OTHER DETAILS, (1) #4 MIN
MATCH VERTICAL BAR SIZE RE: MASONRY WALL SCHEDULE
40 BAR DIA OR 2'-0" WHICHEVER IS LARGER
RE: LINTEL TABLE
HORIZONTAL BARS W/ 180 DEGREE HOOK FOR BARS INTERRUPTED BY OPENING, TYP EA SIDE OF OPENING
HEADER OVER OPENING, RE: TYPICAL DETAILS
2x BEARING WALL
1/2" WOOD SHEATHING,RE: PLAN NOTES FOR NAILING
WOOD BACKUP
RIGID INSULATION
WATERPROOF, RE: ARCH
RE: ARCH
GLAZING,RE: ARCH
MASONRY VENEER, RE: TYPICAL DETAILS FOR
MASONRY VENEER ATTACHMENT
WEEP, RE: ARCH
STEEL ANGLE LINTEL, RE: LOOSE LINTEL TABLE, INSTALL ANGLE W/ OUTSIDE FACE OF VERTICAL LEG
AT INSIDE FACE OF VENEER
C8X11.5 HEADER
CLOSURE V COORDINATE W/ ARCH
3/16 2-12
SEAL
MASONRY VENEER, RE: ARCH
WOOD OR CFS BACKUP RIGID FOAM INSULATION
RIGID FOAM INSULATION
SHEATHING, RE: ARCH
2X-HOOK
HOHMANN & BARNARD HB THERMAL 2-SEAL WING NUT ANCHOR 16"OC MAX EA WAY,
COORDINATE LENGTH WITH INSULATION THICKNESS
CFS OR WOOD STUD WALL
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:1
0 A
M
S013TYPICAL DETAILS -
MASONRY
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS1
TYPICAL REINFORCED MASONRY WALL JOINT REINFORCEMENT
NTS2
TYPICAL REINFORCED MASONRY WALL CONTROL JOINT
NTS3
TYPICAL REINFORCED MASONRY WALL HORIZONTAL REINFORCEMENT CORNERS
NTS4
TYPICAL REINFORCED MASONRY VERTICAL BAR POSITIONERS
NTS5
TYPICAL REINFORCED MASONRY LINTEL TABLE
NTS6
TYPICAL MASONRY PARTITION WALL LATERAL SUPPORT
NTS7
TYPICAL MINIMUM REINFORCEMENT AT MASONRY OPENINGS AND WALL ENDS
NTS9
TYPICAL LOOSE LINTEL TABLE AND DETAIL - MASONRY VENEER
NTS10
TYPICAL MASONRY VENEER ATTACHMENT WITH INSULATION
5. LLV = LONG LEG VERTICAL, SLV = SHORT LEG VERTICAL
4. ALL ANGLES ARE GALVANIZED UNLESS NOTED OTHERWISE.
3. RE: ARCHITECTURAL AND MECHANCIAL DRAWINGS FOR LOCATIONS AND SIZES OFMASONRY OPENINGS.
2. USE ABOVE ANLGE SIZES AT ALL MASONRY OPENINGS EXCEPT WHERE DETAILEDOTHERWISE.
1. WHERE ARCHITECTURAL ASSEMBLIES REQUIRE STEEL COLURE BETWEEN BACKUP ANDINTERIOR FACE OF VENEER, PROVIDE PLATE AS SHOWN, THICKNESS TO MATCH HORIZONTALLEG OF AHGLE, WIDTH PER ARCHITECURAL DRAWINGS.
NOTES:
> 10'-0" CONTACT STRUCTURAL ENGINEER
TO 10'-0" L6x3 1/2x5/16 (LLV) 8"
TO 8'-0" L5x3 1/2x1/4 (LLV) 6"
TO 6'-0" L4x3 1/2x1/4 (LLV) 6"
TO 4'-0" L3 1/2x3 1/2x1/4 6"
MASONRY OPENINGWIDTH ANGLE SIZE
MINIMUM BEARINGEACH END
THIS TABLE IS FOR 4" NOMINAL CLAY OR CMU MASONRY VENEER ONLY
LOOSE LINTEL TABLE - MASONRY VENEER
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
FACE OF WEB
FACE OF WEB
FACE OF WEB
FACE OF WEB
3/4"T A325N BOLTS E70XX ELECTRODES Fy=36 KSI ANGLES Fy=50 KSI BEAMS AND GIRDERS ANGLE LEG THICKNESS=3/8" MIN
MEMBER DEPTH
W8
W10
W12
W14
W16
W18
W21
W24
W27
W30
W33
W36
ROWS OF BOLTS
2
2
3
3
4
5
6
6 [7]
7
8
9
10
MAX COPE DEPTH (in)
MAX COPE LENGTH (in) SINGLE COPE DOUBLE COPE
CAPACITY (k)
NO COPE
TYPICAL SINGLE ANGLE SHEAR CONNECTIONS - ASD (AISC 360-10)
10
10
21
21
34
47
59
59 [72]
72
84
97
109
5 (9)
8 (10)
15 (19)
21
33
47
59
59 [72]
72
84
97
109
10
10
21
21
34
47
59
59 [72]
72
84
97
109
NOTES:1. CONNECTION CAPACITY MUST MEET OR EXCEED REACTION SHOWN ON PLAN. CONTACT STRUCTURAL ENGINEER FOR
ALTERNATE CONNECTION WHEN TABLE VALUES ARE EXCEEDED. 2. ANGLE LEGS MAY BE BOLTED OR WELDED AT CONTRACTOR'S OPTION.3. FABRICATOR MAY CHOOSE ANGLE SIZE BASED ON BOLT GAGE AND MINIMUM EDGE DISTANCES PROVIDED. ANGLE
THICKNESS = 3/8" MINIMUM4. VALUES IN (#) APPLY TO BEAM SIZES W8x15, W10x17, W12x19, AND HEAVIER.5. VALUES IN [#] APPLY TO W24 W/ (7) BOLTS, USE (7) BOLTS WHERE LOAD INDICATED ON PLAN EXCEEDS CAPACITY
OF (6) BOLT CONNECTION. (7) BOLT CONNECTION REQUIRES ENCROACHMENT OF BEAM FILLET (K).6. CAPACITIES ARE BASED ON AISC 360-10, ALLOWABLE STRENGTH DESIGN (ASD). 7. HOLES IN SUPPORTING MEMBER ARE STANDARD HOLES. HOLES IN SUPPORTED BEAM WEB MAY BE STANDARD OR
SHORT-SLOTTED.8. SINGLE ANGLE NOT TO BE USED IN THE CONDITION OF SUPPORTING A CANTILEVERED BEAM WHERE NO FLANGE COVER
PLATES OR FLANGE CONTINUITY WELDS ARE USED.
SUPPORTED MEMBER
SUPPORTING MEMBER
FLIP ANGLE WHERE CONNECTION OCCURS ON OPPOSITE SIDE OF WEBMAX
GAP = 1"
MAXGA = 3"
1 1/
4" MIN
3" TYP
MIN1 1/4"
MAXGA = 2 3/4"
SUPPORTED MEMBER
SUPPORTING MEMBER
MAXGAP = 1"
MAXGA = 3"
1 1/
4" MIN
3" TYP
3" MIN4" MAX
BOLTED-BOLTED
SUPPORTED MEMBER
SUPPORTING MEMBER
3" MIN5" MAX
MAXGAP = 1"
1 1/
4" MIN
3" TYP
.
WELDED-BOLTED
BOLTED-WELDED
ROWS
FLIP ANGLE WHERE CONNECTION OCCURS ON OPPOSITE SIDE OF WEB
MIN1 1/4"
MAXGA = 2 3/4"
FLIP ANGLE WHERE CONNECTION OCCURS ON OPPOSITE SIDE OF WEB
MIN1 1/4"
MIN1 1/4"
SINGLE ANGLE TO WF COLUMNWF COLUMN
SUPPORTED MEMBER
FLIP ANGLE WHERE CONNECTION OCCURS ON OPPOSITE SIDE OF COLUMN
GAP =1" MAX
ANGLES MAY BE BOLTED-BOLTED OR BOLTED-WELDED, SEE BELOWFOR DIMENSIONAL LIMITATIONS
1 1/4" MIN
1 1/4" MIN
.
.
ROWS
ROWS
1/4
1/41/2" TOPRETURN
1
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
2
2
2
2 1/2
2 1/2
4
4
4
4
5
5
5 1/2
6
6
7
7
7
TYPICAL SHEAR TAB (SINGLE PLATE) CONNECTIONS - ASD (AISC 360-10)BEAM TO COLUMN OR WIDE FLANGE GIRDER
3/4"T A325N BOLTS E70XX ELECTRODES Fy=36 KSI TABS Fy=50 KSI BEAMS AND GIRDERS Fy=46 KSI HSS Fy=35 KSI PIPE
12 (15)
14 (15)
26 (28)
28
41
53
56
56 [69]
69
5 (9)
8 (12)
15 (19)
26
33
5 (6)
6
13
13
23
35
47
47 [60]
60
53
56
56 [69]
69
82 7382
94 8694
107 99107
MEMBER DEPTH
W8
W10
W12
W14
W16
W18
W21
W24
W27
ROWS OF BOLTS
2
2
3
3
4
5
6
6 [7]
7
MAX COPE DEPTH (in)
MAX COPE LENGTH (in)
SINGLE COPE DOUBLE COPE
1
1.5
1.5
1.5
1.5
1.5
1.5
2
2
4
4
4
4
5
5
5.5
6
6
"A"<=3 1/2"
W30 8 2 7
W33 9 2.5 7
W36 10 2.5 7
NO COPE
"A"<=3"
13 (16)
15 (16)
29
29
42
54
59
59 [72]
72
84
97
109
NOTES:1. CONNECTION CAPACITY MUST MEET OR EXCEED REACTION SHOWN ON PLAN. CONTACT STRUCTURAL ENGINEER
FOR ALTERNATE CONNECTION WHEN TABLE VALUES ARE EXCEEDED. 2. VALUES IN (#) APPLY TO BEAM SIZES W8x15, W10x17, W12x19, AND HEAVIER.3. VALUES IN [#] APPLY TO W24 W/ (7) BOLTS, USE (7) BOLTS WHERE LOAD INDICATED ON PLAN EXCEEDS
CAPACITY OF (6) BOLT CONNECTION. (7) BOLT CONNECTION REQUIRES ENCROACHMENT OF BEAM FILLET (K).4. CAPACITIES ARE BASED ON AISC 360-10, ALLOWABLE STRENGTH DESIGN (ASD). 5. HOLES IN SHEAR TAB MAY BE EITHER STANDARD OR SHORT-SLOT HOLES.
"A"=5" DOUBLE COPE
CAPACITY (K)
STEEL GIRDER
ROWS
SEE COLUMN GRAPHICFOR DIMENSIONAL LIMITATIONS
STEEL BEAM
NOTE TO DETAILER:OFFSET SHEAR TABS WHEN BEAMS ON
OPPOSITE SIDES OF GIRDER ALIGN.
SHEAR TAB TO WF GIRDER
SKEWED SHEAR TAB DETAIL
"A"
TOP FLANGE REMOVED FOR CLARITY
1/4
1/4TYP
1/4
1/4T=0_
(1/4)
1/4T=45_ NOPLATE PREP
T`45_
NOTES:1. RE: AISC TABLE 10-14C FOR WELD
AND PLATE PREP REQUIREMENTS.2. IF T>45_, USE BENT PLATE
CONNECTION ON OBTUSE SIDE. ENGINEER TO PROVIDE OR VERIFY DETAIL.
3/8
1/40_<T`17_ NOPLATE PREP
1/2
1/417_<T`30_ NOPLATE PREP
5/16
1/430_<T<45_ W/PLATE PREP
.
ROWS
a COL AND BEAM
"A"3/8" PLATE, TYP
STEEL BEAMWF OR HSS/PIPE COLUMN, 1/4" MIN WALL THICKNESS
FOR HSS AND PIPES
SHEAR TAB TO WF COLUMNSIMILAR CONNECTION TO FACE OF HSS OR PIPE COLUMN
1/4
1/4TYP
TYP
3"
AT WF COLUMN WEB, RE: EXTENDED SHEAR TAB
TYPICAL DETAIL AS REQUIRED
MIN
1 1/
4"
1 1/2" MIN1 1/2" MIN
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:1
2 A
M
S014TYPICAL DETAILS - STEEL
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS1 TYPICAL SINGLE ANGLE SHEAR CONNECTIONSNTS2 TYPICAL SHEAR TAB CONNECTIONS
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
AA
H + 1.5T MAX W H + 1.5T MAX
H +
1.5T MAX
WH +
1.5T MAX
LIMIT OF MILD REBAR
LIMIT O
F MILD R
EBAR
TOP REBAR (TYP)STAGGER 12" EW UNO
TOP R
EBAR
(TYP)
STAG
GER
12" EW
UNO
TOP REBAR AT 12" OC MAX
BANDED PT TENDONS (MAX 4 STRANDS PER GROUP)
UNIFORM PT TENDONS SPACED @8x SLAB THICKNESS OR 5'-0" OC MAX UNO
COLUMN BELOW
DROP PANEL BELOW WHERE INDICATED ON PLAN
NOTE:TWO STRANDS MIN TO PASS DIRECTLY OVER COLUMN EW
LEGEND:T = SLAB THICKNESSW = COLUMN WIDTHH = CAP/DROP DEPTH BELOW SLAB SOFFIT AT FACE OF COLUMN
H + 1.5T MAX W H + 1.5T MAX
W
LIMIT OF MILD REBAR
TOP R
EBAR
(TYP)
STAG
GER
12" EW
UNO
NOTE:TWO STRANDS MIN TO PASS DIRECTLY OVER COLUMN EW
LEGEND:T = SLAB THICKNESSW = COLUMN WIDTHH = CAP/DROP DEPTH BELOW SLAB SOFFIT AT FACE OF COLUMN
H +
1.5T M
AXH +
1.5T M
AX
LIMIT O
F MILD R
EBAR
TOP REBAR (TYP)STAGGER 12" EW UNO
UNIFORM PT TENDONS SPACED @8x SLAB THICKNESS OR 5'-0" OC MAX
SLAB EDGE
16 MIN
DROP PANEL BELOW WHERE INDICATED ON PLAN
COL BELOW
HOOK BARS AT SLAB EDGE
BANDED PT TENDONS (MAX 4 STRANDS PER GROUP)
TOP REBAR AT 12" OC MAX
2"
NA
3/8T
2T
D
2T
#3 HAIRPIN IN BANDED DIRECTION ONLY TOTAL EQUAL TO NUMBER OF
ANCHORS PLUS 1
T= SLAB DEPTHD= T-2"
#4 T&B AT BANDED PT TENDON EXTEND 9" BEYOND
LAST ANCHOR EACH END
FULLY ENCAPSULATED PT TENDON
EQEQ
T
1'-4" GROMMET
PT TENDON STRESSING TAIL, AFTER CUTTING PROVIDE WATERTIGHT SEAL OF WEDGE CAVITY.
SUPPORT BARS @42"OC MAX
T
3/8T 1'-4" MIN
NA
STRESSING TAIL
GROMMET
NAIL TO FORM
ANCHOR
GREASED AND PLASTIC WRAPPED
STRAND
DEAD END STRESSING END
8" M
IN
CLEAR
UNO
4" MIN
61
1'-0" MIN STRAIGHT
DISTANCE BETWEEN POINTS OF TANGENCYIS GOVERNED BY 1:6 SLOPE AS SHOWN
BAN
DED
PT TENDONS
9" M
IN E
ACH S
IDE
TYP INTERMED
IATE
THINNER
, PLACE
ANCHORS
SIDEW
AYS
@ 6
" MIN O
C
FOR 7
" SLAB
S OR THICKER
, PLACE
ANCHORS
UPRIGHT @3" MIN O
C. FO
R 6
1/2" SLAB
S OR
8" M
IN
8" MIN
2T
HAIRPIN REINF
NOTES:1. STRESS A MINIMUM OF TWO PT TENDONS
PERPENDICULAR TO BANDED TENDONS BEFORE BANDED TENDONS ARE STRESSED
2. T = SLAB DEPTH
BANDED PT TENDONS (MAX 4 STRANDS PER
GROUP)
UNIFORM PT TENDONS RE: NOTE 1
#3 HAIRPIN REINF
#4 TOP & BOT
(2) #4 36"
36"BARS AT CORNER
3/8T(2) #3@3"OC
HAIRPIN AT CORNERS
(2) #4 CONT
SLAB EDGE
T-2"
2"
NA
T= SLAB DEPTHD= T-2"
EQEQ
T
1'-4"GROMMET
PT TENDON STRESSING TAIL, AFTER CUTTING PROVIDE WATERTIGHT SEAL OF WEDGE CAVITY.
T
1'-4" MIN
NA
STRESSING TAIL
GROMMET
NAIL TO FORM
ANCHOR CASTING
GREASED AND PLASTIC WRAPPED STRAND
DEAD END STRESSING END
CHAIRS @3'-0"OC MAX
1/2" CLEAR
FORMS
#4 T&B CONT BACKUP BARS TIED
TO PT TENDON
CHAIR
FULLY ENCAPSULATEDPT TENDON
SUPPORT BARS @42"OC MAX
4" UNO LIMIT OF PT TENDON BAND 4" UNO
C C
MID DEPTH TYP
HAIRPIN
REBAR TOP AND BOTTOM
PT ANCHOR
PT SLAB
FOR T=7" OR GREATER, PLACE ANCHORS UPRIGHT W/ C=3" MIN
FOR T=6 1/2" OR LESS, PLACE ANCHORS HORIZ W/ C=6" MIN
EDGE OF SLAB VIEW
TOP OF SLAB BANDED PT TENDONS (NUMBER OF TENDONS PER BUNDLE MAY VARY)
TOP UPPER REBAR, RE: PLAN
TOP LOWER REBAR (SHOWN BEYOND UNIFORM PT), RE: PLAN
UNIFORM PT TENDON
2" MINCLR TYP
MIN
COVE
R
SUPPORT REBAR, TYP
CHAIR TYP
UNIFORM PT TENDONS
TOP UPPER REBAR, RE: PLAN
BANDED PT TENDON
TOP OF SLAB
TOP LOWER REBAR, RE: PLAN
SUPPORT REBAR, TYP
CHAIR TYP
2" MIN CLR TYP
MIN
COVE
R
NA
#4 HAIRPIN PLACED RADIALLY TO HOLD TENDONS IN PLANE OF SLAB PLACE OVER CURVED LENGTH OF PT TENDON AT 18" MAX SPACING
2'-0"
4"
PT SLAB
6"TYP
1'-6" MAX
WHER
E CUR
VATURE
EXCEEDS
1:12, 2
" GAP
BETWEEN
TEND
ONS
>1
12
TENDON
HAIRPIN
PLAN
SECTION
SECTION A-A
EDGE OF OPENING WHERE IT OCCURSOPENING OR CENTER
OF TENDON TURN.
.
#4x3*D MIN TOP & BOTD
W
45° TYP
SLAB EDGE
TENDON
NOTE:OPENINGS WITH DIMENSIONS GREATER THAN 10" REQUIRE TRIM REBAR
STEEL PIPE INSERTED (SCHED 40) IS REQD WHEN SLAB OPENING IS WITHIN 45_ BEARING CONE OF TENDON ANCHOR
OPENINGS FURTHER THAN 1.5 TIMES THE DIAMETER (D) OR WIDTH (W) BUT NOT LESS THAN 18" MIN FROM ANCHOR DO NOT REQUIRE STEEL PIPE INSERTED
18" MIN
1.5*W OR 1.5*D
3" CLEAR
3 1/8" CLEAR
CLEAR
6" M
IN
112
3'-0" MIN STRAIGHT
12" MIN
*
* WHERE PT TENDON CURVATURE EXCEEDS 1:12 HAIRPINS REQD, RE: TYP HAIRPIN AT PT TENDON TURNS DETAIL
#4 HAIRPIN AT CORNERS OF OPENING TYP
PT TENDON
#4 HAIRPINS, TYP
MAXIMUM CURVATURE WITHOUT HAIRPINS
18" TYP
3"
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:1
4 A
M
S015POST-TENSIONED
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS1
TYPICAL PT SLAB TOP REINFORCEMENT AT INTERIOR COLUMNS
NTS2
TYPICAL PT SLAB TOP REINFORCEMENT AT EXTERIOR COLUMNS
NTS3 TYPICAL BANDED PT SLAB TENDON ENDS
NTS4
TYPICAL PT SLAB FLARING OF BANDED TENDONS AT SLAB EDGE
NTS5 TYPICAL PT SLAB DISTRIBUTED TENDON ENDS
NTS6
TYPICAL PT SLAB REINFORCEMENT OF TENDON BAND AT SLAB EDGE AND INTERMEDIATE STRESSING
NTS7
TYPICAL PT SLAB SECTION THROUGHBANDED TENDON AT COLUMN
NTS8
TYPICAL PT SLAB SECTION THROUGHDISTRIBUTED TENDON AT COLUMN
NTS9
TYPICAL HAIRPIN REINFORCING ATPT TENDON TURNS
NTS10 TYPICAL OPENINGS AT PT SLAB ANCHORAGE
NTS11 TYPICAL PT TENDON PLACEMENT AT OPENINGS
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
L1/2 L1/2 L2/2 L2/2 L3/2 L3/2
L1 L2 L3
EXTERIOR SPAN EXTERIOR SPANINTERIOR SPAN
NA NA
STRESSINGEND
A TYP
RE: P
LAN
RE: P
LAN
NOTES: A = 0.1L FOR UNIFORM SLAB NA IS AT MID-DEPTH
CONTROL POINTS ASSHOWN ON PLAN
TERMINATE TENDONS STAGGER @ 12" AT BANDS (ANCHOR AT NA)
HIGH POINT RE: PLAN
SPAN/416" STRAIGHT UNO
EQ EQ
SUPPORT WIDTH
#4 CONTUNIFORM TENDONS
BOTTOM REINF, RE: PLANBANDED TENDONS
CLEAR2" MIN
SUPPORT BAR OR SLAB BOLSTER
1/41/2
RE: NOTE 4
5" x 2
1/2"
1/2
2'-10 207/256"
.
.
.
11"
6 3 4 12
5
BULKHEAD
S5CP+ STRESSING END ASSEMBLY
NOTES:1. LOCATE ANCHOR AT BULKHEAD RE: PROJECT PLANS.2. INSTALL GROMMET FLUSH BETWEEN BULKHEAD ANDANCHOR FOR TIGHT SEAL.3. SLIDE SLEEVE TIGHT AGAINST ANCHOR. BE SURE NO BARESTRAND IS EXPOSED. TAPE IF NECESSARY.4. AFTER POURING, AT TIME OF STRESSING, REMOVEGROMMET AND INSERT WEDGES.5. AFTER STRESSING, CUT STRAND TO WITHIN 1/8" OFEND OF END CAP AND GREASE END CAP PRIOR TOINSERTING IT TIGHT AGAINST ANCHOR6. PATCH STRESSING POCKET RE: PROJECT PLANS.
6
GROMMET S5CP+
END CAP S5CP+54321ITEM DESCRIPTION
ANCHORAGE S5CP+PROTECTION SLEEVE S5CP+
MONOWEDGES TYPE 1.5STRAND (GREASE AND COATED)
1 "
2 " 2 "
1/4
5" x 2
1/2"
1/22'-10 227/256"
.
.
.
11"
3 4 12
5
S5CP+ STRESSING END ASSEMBLY
.
BULKHEAD
NOTE 1
RE:
NOTES: 1. LOCATE ANCHOR AT BULKHEAD RE: PROJECT PLANS. 2. IF FABRICATED AT SHOP, WEDGES, GREASE CAP, AND SLEEVE WILL BE ASSEMBLED TIGHT TO ANCHOR. 3. IF FIELD SEATING IS REQUIRED, BE SURE ALL COMPONENTS ARE TIGHT TO ANCHOR, BE SURE NO BARE STRAND IS EXPOSED, AND TAPE IF NECESSARY.
54321ITEM DESCRIPTION
ANCHORAGE S5CP+PROTECTION SLEEVE S5CP+END CAP S5CP+MONOWEDGES TYPE 1.5STRAND (GREASE AND COATED)
1 " 2 "
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:1
5 A
M
S016POST-TENSIONED
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS1
TYPICAL PT SLAB PROFILE FORREVERSED PARABOLA TENDONS
NTS2
TYPICAL PT SLAB SECTION THROUGHBANDED TENDONS AT MIDSPAN
NTS3
TYPICAL ENCAPSULATEDPT SYSTEM (STRESSED END)
NTS4
TYPICAL ENCAPSULATEDPT SYSTEM (DEAD END)
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
1. TOP OF SLAB ELEVATION INDICATED ON PLAN. 2. TOP OF WALL ELEVATION INDICATED ON PLAN. 3. TOP OF BRICK LEDGE, RE: ARCH.4. DRILLED PIER FOUNDATIONS CONSIST OF DRILLED PIERS
WHERE SHOWN ON PLAN. UNLESS INDICATED OTHERWISE DRILLED PIERS AND PIER CAPS SHALL BE CENTERED BELOW WALLS AND COLUMNS. WHERE PILASTERS OCCUR PIERS ARE TO BE CENTERED BELOW COLUMN ABOVE PILASTER. RE: DRILLED PIER SCHEDULE AND TYPICAL DETAILS.
5. SOG (SLAB-ON-GRADE) WHERE SHOWN ON PLAN CONSISTS OF REINFORCED CAST-IN-PLACE CONCRETE SLAB PLACED ON FREE DRAINAGE COMPACTED BASE OVER SUITABLE SUBGRADE MATERIAL AS SPECIFIED BY THE GEOTECHNICAL ENGINEER AND GEOTECHNICAL REPORT. RE: PLAN FOR SOG THICKNESS, REINFORCING, AND ELEVATIONS. REINFORCING SHALL BE CHAIRED MID-HEIGHT OF THE SLAB, UNO. CONTROL JOINTS SHALL HAVE A MAXIMUM SPACING OF 15'-0". RE: TYPICAL DETAILS AND GENERAL NOTES FOR ADDITIONAL INFORMATION.
6. ALL CONCRETE COLUMNS ARE TYPE C1.7. RE: SHEETS S000-S002 FOR GENERAL NOTES AND
GENERAL LEGENDS.8. RE: SHEETS S010a-S013 FOR TYPICAL DETAILS.9. RE: SHEET S500 AND S501 FOR SCHEDULES.
FOUNDATION PLAN NOTES:
1 2 4 67
7
A
B
D
F
H
1S300
3S300
2S300
4S300
4" SLAB ON GRADE
#3@
18"OC
#3@18"OC
4" SLAB ON GRADE
REENTRANT CORNER, RE: TYP DETAILS
3S400
G
12
4S400
4S400
4S400
4S400
#3@
18"OC
#3@18"OC
13'-8
3/4"
4'-2"
3'-8"
10'-4 7/8" 2'-2"
T/SOG
100'-0"
3S400
3S400
CONTROL JOINTS, RE: TYP DETAILS
T/SOG
100'-4"
SLOPE
35
C
E
I
A.1
A.5
C.1
C.8
D.8
E.8
1311
10
8
21'-2 1/4" 20'-11 1/2" 21'-2 1/4"
22'-7"
5'-10"
95.98°
30'-10 1/2"
5'-8
1/2"
30'-10 1/2"
19'-6"
19'-6"
2'-0"
25'-3"
44'-3"
29'-10 57/25
6"
6'-4"
20'-
3 1/
2"
19'-10 3
/4"
19'-10 3
/4"
28'-
11"
11'-0"
3'-8"
10"
5'-0"
1'-2"
3'-10"
26'-9"
3'-0"
6"
2"
9"
95'-10"/73'-0"
78k/0k/0kP1
97'-0"/73'-0"
67k/0k/0kP1
3S400
97'-0"/73'-0"
83k/0k/0kP197'-0"/67'-0"
140k/0k/0kP397'-0"/70'-0"
130k/0k/0kP2
97'-0"/70'-0"
100k/0k/0kP2
97'-0"/70'-0"
114k/0k/0kP295'-10"/70'-0"
117k/0k/0kP2
97'-0"/70'-0"
132k/0k/0kP2
97'-0"/70'-0"
132k/0k/0kP295'-10"/70'-0"
129k/0k/0kP2
97'-0"/73'-0"
45k/0k/0k P1
97'-0"/70'-0"
116k/0k/0kP2
97'-0"/70'-0"
136k/0k/0kP2 95'-10"/67'-0"
142k/0k/0kP3
95'-0"/73'-0"
42k/0k/0kP1
95'-0"/73'-0"
100k/0k/0kP1
95'-0"/70'-0"
117k/0k/0kP2
95'-0"/67'-0"
158k/0k/0kP3
95'-0"/70'-0"
105k/0k/0kP2
95'-0"/73'-0"
95k/0k/0kP1
97'-0"/70'-0"
113k/0k/0k P2
97'-0"/73'-0"
62k/0k/0k P1
97'-0"/73'-0"
36k/0k/0kP1
97'-0"/73'-0"
65k/0k/0kP1
95'-0"/73'-0"
83k/0k/0kP1
95'-0"/73'-0"
86k/0k/0kP1
97'-0"/73'-0"
83k/0k/0kP197'-0"/67'-0"
140k/0k/0kP397'-0"/70'-0"
130k/0k/0kP2
97'-0"/73'-0"
96k/0k/0kP1
97'-0"/67'-0"
145k/0k/0kP397'-0"/67'-0"
145k/0k/0kP3
97'-0"/67'-0"
145k/0k/0kP397'-0"/67'-0"
145k/0k/0kP397'-0"/73'-0"
96k/0k/0kP1
5S400
97'-0"/70'-0"
132k/0k/0kP2
GB1
GB1
GB1
GB4
GB4
GB4
GB4
GB4
GB3
GB2
GB2
GB3
GB2
GB2
GB8B
GB2
GB8A
GB8A
GB8A
GB8A
GB7
GB8A
GB8A
GB7
GB7
GB1
GB1
GB1
GB1
GB1
GB1
GB5
GB6
GB5
GB6
GB5
GB6
GB5
GB6
A30
'-2"
B30
'-2"
A6'-0"
A6'-10"
HD1.3
HD1.3
D21'-7"
HDX
HD1.3
B 21'-10"HD1.2
HD1.2
D 22'-10"
HD1.4
HD1.4
B 21'-10"HD1.3
HD1.3
C18'-3"
HD1.3
HD1.3
HD1.1
HD1.1
HD1.3
HD1.1
6S400
TYP UNO
D 21'-10"
HD1.3
HD1.3
HD1.2
HD1.2
67'-5
1/2"
SLOPE
W1
W1
W1
W1
W2
W2
W2
W4
W5
W5
W5
W5
W5.2
W5.2
W5.2
W5
W5.1
W5.1
W5W5
W5
W5
W6.1
W6.1
W4
W4
W4
5S300
4'-9"
39'-0"
9"
1'-0"
100'-0"
11.3°
HSS5x
5x1/2
HSS4x4x
1/4
HSS4x4x
1/4
HSS4x4x
1/4 HSS4x4x
1/4
A6'-2"
HD1.3
HD1.3
A21'-7"
HD1.3
HD1.3
B 6'-6"
HD1.3
T/SOG
98'-1 1/4"
95'-0"/73'-0"
88k/0k/0k P1
97'-0"/70'-0"
122k/98k/46k P4
93'-8"/70'-0"
73k/9k/89k P4
93'-8"/-27'-0"
58k/6k/4kP4
97'-0"/73'-0"
70k/0k/0k P1
97'-0"/70'-0"
105k/0k/0k P2
93'-8"/-27'-0"
128k/77k/46k P493'-8"/-27'-0"
96k/52k/5kP4
a14'-
5 1/2"
a14'-
5 1/2"
aa3'-10"
5'-8
1/2"
3'-5"
a
6'-11"
5'-8
1/2"
a
6'-11"
T/SOG
99'-2"
95'-10"/73'-0"
100k/0k/0kP1
95'-10"/70'-0"
65k/0k/0kP4
95'-10"/73'-0"
100k/0k/0kP1
97'-0"/70'-0"
65k/0k/0kP4
24"X24" PLASTER FORM INTEGRALLY
WITH GRADE BEAM TYP
29'-1 1/2"
7'-1"
aa
8'-4 17/32"
6'-5 1/256"
aa
2'-4" 6'-5" 2'-4"
2'-4"
8'-0"
2'-4"
1'-2"
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:1
5 A
M
S161FOUNDATION AND 1ST
FLOOR PLAN
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
KEYED NOTES FOUNDATION
# DESCRIPTION
1 insert instance comment here
1/8" = 1'-0"1 FOUNDATION AND 1ST FLOOR PLAN
N
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR HDR HDR HDR HDR HDR HDR HDR HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDRHDRHDRHDRHDRHDR
1. FLOOR CONSTRUCTION: APA SPAN RATED 24" OC SINGLE FLOOR SHEATHING (3/4" NOMINAL THICKNESS) ON PREFABRICATED 4x2 WOOD TRUSSES AND WOOD I-JOISTS. RE: ARCH FOR MORE INFORMATION.
2. BEAM REACTIONS LESS THAN 8 KIPS ARE NOT SHOWN.4. RE: SHEETS S000-S002 FOR GENERAL NOTES AND
GENERAL LEGENDS.5. RE: SHEETS S010-S016 FOR TYPICAL DETAILS.6. RE: SHEETS S500-S501 FOR COLUMN, SHEAR WALL,
HOLDOWN, AND BASE PLATE SCHEDULES. 8. RE: SHEET S-003 FOR LOAD KEYS.9. HEADERS, 'HDR', FOR THE FLOOR BELOW APPEAR ON
THIS PLAN.
FLOOR FRAMING PLAN NOTES:
1 2 4 6
6
7
7
A
B
D
F
H
3S410
4S410
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
9 1/2" TJI 210@24"OC
18" FLOOR TR
USS@
19.2"OC
18" FLOOR TR
USS@
19.2"OC
18" FLOOR TR
USS@
19.2"OC
18" FLOOR TR
USS@
19.2"OC
T/SHEATHING113'-6"
9 1/2" TJI 2
10@24"OC
9 1/
2" TJI 210@12"OC
(2) 9
1/2" TJI [email protected]"OC
G
T/SLAB113'-6"
10" PT SLAB
12
W1
W1
W1
W1
W2
W2
W2
W4
W2
W3.1
W2
W4
W5
W5
W5
W5
W5.2
W5.2
W5.2
W5.1
W5.1
W5
W5.1
W5.1
W5W5
W5
W5
W4
W4
W4
W4
W4
W4
W4
4S410
7S410
9S410
3S410
5S410
10S410
10S410
10S410
11S410
12S410
13S410
SIM
35
5
C
E
I
A.1
A.5
C.1
C.8
D.8
E.8
1311
10
8
21'-2 1/4" 20'-11 1/2" 21'-2 1/4"
22'-7"
5'-10"
95.98°
30'-10 1/2"
5'-8
1/2"
30'-10 1/2"
4'-9"
19'-6"
19'-6"
2'-0"
25'-3"
44'-3"
29'-10 57/25
6"
6'-4" 6'-0 85/128"
1'-8 73/256"
6 11/256
"
20'-
3 1/
2"
19'-10 3
/4"
19'-10 3
/4"
28'-
11"
11'-0"
TYP AT DEMISING
11S410
10S410
A30
'-2"
B30
'-2"
A6'-0"
HD8
HD8
C21'-7"
HD7
HD7
A 21'-10"
C 21'-10"
A 22'-9"HD7
HD7
A18'-3"
HD6
HD6
HD5
HD5
HD6
HD6
D 21'-10"
A4'-0"
HD8
HD8
B 6'-0"
C11'-8"
HD1.3
C 10'-0"
HD1.3
B17'-2"
B19'-2"
A19'-2"
B6'-8"
HD1.3
HD1.3
HD1.3
HD1.3
HD1.3
HD1.3
HD1.3
HD1.3
HD1.3
HD1.3HD1.3
HD1.3
HD7
HD8
HD5
HD7
HD8
HD5
W2
W6.1
W6.1
W5.1
W6.1
W6.1
W2
W5.1
W5.1
W6.1
W6.1
W4
W4
W4
HSS10x5x3/8 LOW
HSS5x5x3/8 HIGH
HSS10x5x3/
8 HIGH
HSS5x5x3/
8 LOW
A4'-10"
HD8
HD8
A 6'-8" HD8HD8
A21'-7"
HD5
HD5
4S411
4S411
4S411
C4x7.25TYP
6S411
6S411
6S411
6S411
6S411
6S411
WT9x2
5
TYP
6S411
6S411
HSS5x5x3/8
(2) 1 3/4"X9 1/2" LVL TYP (4) SIDES
OF SHAFT
CANOPY BELOW TYP
1. PT SLAB WHERE SHOWN ON PLAN CONSISTS OF REINFORCED AND POST-TENSIONED CAST-IN-PLACE CONCRETE SLAB. RE: PLAN FOR SLAB THICKNESS, REINFORCING AND PT. RE: PLAN FOR PT DRAPES. UNLESS NOTED OTHERWISE REINFORCING COVER DEFINED BY THE TABLE BELOW.
2. PT TENDON PROFILES TAKE PRECEDENCE OVER MILD REINFORCING ELEVATIONS. MILD REINFORCEMENT SHALL BE PLACED SUCH THAT IT DOES NOT INTERFERE WITH TENDON PROFILES.
3. ALL TENDONS AND TENDON ANCHORAGES SHALL BE FULLY ENCAPSULATED. PT SHEATHING SHALL BE CONNECTED TO ALL STRESSING, INTERMEDIATE, AND FIXED ANCHORAGES IN A WATERTIGHT FASHION IN ACCORDANCE WITH ACI 318.
4. AT COLUMN LOCATIONS, A MINIMUM OF TWO TENDONS IN EACH DIRECTION SHALL PASS OVER THE AREA ENCLOSED BY THE TIES OF THE COLUMN BELOW.
5. IN BANDED DIRECTION, TYPICAL SPACING BETWEEN TENDON GROUPS IS 1'-0" OC. SPACING MAY BE EXCEEDED WHERE REQUIRED TO SWEEP AROUND PENETRATIONS OR AS SHOWN ON PLANS.
6. IN UNIFORM DIRECTION, SPACING BETWEEN ADJACENT TENDONS SHALL NOT EXCEED 5'-0" OC. CONTRACTOR TO ENSURE THAT SPACING IS MAINTAINED WHERE TENDONS ARE REQUIRED TO SWEEP AROUND OPENINGS. UNLESS TENDON LOCATIONS ARE SPECIFICALLY DIMENSIONED, UNIFORM TENDONS MAY BE ASSUMED EQUALLY SPACED BETWEEN COLUMNS.
7. IN SLOPING AREAS, SLOPE TOP AND BOTTOM OF SLAB TO MAINTAIN SLAB THICKNESS, UNO.
8. RE: ARCH AND MEP FOR PENETRATIONS NOT SHOWN ON STRUCTURAL PLANS.
9. PRIOR TO DETAILING AND FABRICATION, VERIFY ALL ELEVATIONS AND DIMENSIONS WITH ARCHITECTURAL PLANS.
10. RE: SHEET S000-S002 FOR GENERAL NOTES AND GENERAL LEGENDS
11. RE: SHEET S003 FOR LOAD KEYS12. RE: SHEET S010-S016 FOR TYPICAL DETAILS13. RE: SHEET S162 FOR FRAMING PLAN14. RE: SHEET S162R FOR REINFORCEMENT PLAN15. RE: SHEET S162PT FOR PT TENDON PLANS16. RE: SHEET S500 FOR SCHEDULES
POST-TENSIONED CONCRETE PLAN NOTES:
AREA
2 HR FIRE RATING AND LESS
TOP REINF BANDED PT DIRECTION
1 1/2"
TOP REINF UNIFORM PT DIRECTION
1"
PT REINFORCING COVER
AREATOP REINF IN BANDED PT DIRECTION
TOP REINF IN UNIFORM PT DIRECTION
MILD REINFORCING COVER
2 HR FIRE RATING AND LESS
1" 1 3/4"
BOTTOM REINF LOWER
LAYER
1"
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:1
8 A
M
S162LEVEL 2 FRAMING PLAN
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
1/8" = 1'-0"1 LEVEL 2 FRAMING PLAN
N
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
F
F
H
H
G
G
12
E
E
I
I
1311
10
8
WOOD FRAMING RE: 1/S162RE: 1/S162
8 .5
1
6
8.5
78 .5
1
6
8.5
78 .5
1
6
8.5
78 .5
1
6
8.5
78 .5
1
6
8.5
78 .5
1
6
8.5
78 .5
1
6
8.5
78 .5
1
6
8.5
7
7 75
75
78.5
57
8.55
74.5
8.55
74.5
8.55
8.54.5
8.55
8.54.5
8.58.5
4.58.5
8.54.5
8.54.5
8.58.5
7 74
74
78.5
47
8.54
73
8.54
38.5
48.5
38.5
8.53
8.58.5
38.5
38.58.5
7 71
71
78.5
17
14.51 1
3.53.53.5
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S
3S3S3S
3S3S
3S3S
3S3S
5 5 5 5 5 5 5 5
5 5 5 5 5 5 5
5 5 5 5 5 5
5 55 5 5
5 5 5
5 5 5
5 5 5 5 5
5 5 5 5 5 5
5 5 5 5 5 5 5
5 5 5 5 5 5 5 5
F
F
H
H
G
G
12
E
E
I
I
1311
10
8
WOOD FRAMING RE: 1/S162RE: 1/S162
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
2.5
2.5
2.5
2.5
2.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
1
1
1
1
1
1
1
1
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
1
1
1
1
1
6
6
6
6
6
6
6
3
3
3
3
3
3
3
3
8
8
8
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
8
8
8
8
3
3
3
3
3
3
3
3
8
8
8
9
9
9
9
9
9
9
9
1
1
1
5.5
5.5
5.5
5.5
5.5
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S
3S3S
3S
3S
3S
3S
3S
3S
3S
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
3S
LOW POINT
1'-0"
5
5
5
1. PT SLAB WHERE SHOWN ON PLAN CONSISTS OF REINFORCED AND POST-TENSIONED CAST-IN-PLACE CONCRETE SLAB. RE: PLAN FOR SLAB THICKNESS, REINFORCING AND PT. RE: PLAN FOR PT DRAPES. UNLESS NOTED OTHERWISE REINFORCING COVER DEFINED BY THE TABLE BELOW.
2. PT TENDON PROFILES TAKE PRECEDENCE OVER MILD REINFORCING ELEVATIONS. MILD REINFORCEMENT SHALL BE PLACED SUCH THAT IT DOES NOT INTERFERE WITH TENDON PROFILES.
3. ALL TENDONS AND TENDON ANCHORAGES SHALL BE FULLY ENCAPSULATED. PT SHEATHING SHALL BE CONNECTED TO ALL STRESSING, INTERMEDIATE, AND FIXED ANCHORAGES IN A WATERTIGHT FASHION IN ACCORDANCE WITH ACI 318.
4. AT COLUMN LOCATIONS, A MINIMUM OF TWO TENDONS IN EACH DIRECTION SHALL PASS OVER THE AREA ENCLOSED BY THE TIES OF THE COLUMN BELOW.
5. IN BANDED DIRECTION, TYPICAL SPACING BETWEEN TENDON GROUPS IS 1'-0" OC. SPACING MAY BE EXCEEDED WHERE REQUIRED TO SWEEP AROUND PENETRATIONS OR AS SHOWN ON PLANS.
6. IN UNIFORM DIRECTION, SPACING BETWEEN ADJACENT TENDONS SHALL NOT EXCEED 5'-0" OC. CONTRACTOR TO ENSURE THAT SPACING IS MAINTAINED WHERE TENDONS ARE REQUIRED TO SWEEP AROUND OPENINGS. UNLESS TENDON LOCATIONS ARE SPECIFICALLY DIMENSIONED, UNIFORM TENDONS MAY BE ASSUMED EQUALLY SPACED BETWEEN COLUMNS.
7. IN SLOPING AREAS, SLOPE TOP AND BOTTOM OF SLAB TO MAINTAIN SLAB THICKNESS, UNO.
8. RE: ARCH AND MEP FOR PENETRATIONS NOT SHOWN ON STRUCTURAL PLANS.
9. PRIOR TO DETAILING AND FABRICATION, VERIFY ALL ELEVATIONS AND DIMENSIONS WITH ARCHITECTURAL PLANS.
10. RE: SHEET S000-S002 FOR GENERAL NOTES AND GENERAL LEGENDS
11. RE: SHEET S003 FOR LOAD KEYS12. RE: SHEET S010-S016 FOR TYPICAL DETAILS13. RE: SHEET S162 FOR FRAMING PLAN14. RE: SHEET S162R FOR REINFORCEMENT PLAN15. RE: SHEET S162PT FOR PT TENDON PLANS16. RE: SHEET S500 FOR SCHEDULES
POST-TENSIONED CONCRETE PLAN NOTES:
AREA
2 HR FIRE RATING AND LESS
TOP REINF BANDED PT DIRECTION
1 1/2"
TOP REINF UNIFORM PT DIRECTION
1"
PT REINFORCING COVER
AREATOP REINF IN BANDED PT DIRECTION
TOP REINF IN UNIFORM PT DIRECTION
MILD REINFORCING COVER
2 HR FIRE RATING AND LESS
1" 1 3/4"
BOTTOM REINF LOWER
LAYER
1"
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:2
1 A
M
S162PTLEVEL 2 PT TENDON
PLANS
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
1/8" = 1'-0"1 LEVEL 2 BANDED TENDON PLAN
1/8" = 1'-0"2 LEVEL 2 REINFORCEMENT PLAN
N
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
F
F
H
H
G
G
12
E
E
I
I
1311
10
8
WOOD FRAMING RE: 1/S162RE: 1/S162
(6)#6Tx15'-6"@
30"OC
(5)#6Tx14'-0"
@36"OC
(5)#6Tx34'-0"
@24"OC
(5)#6Tx10'-6"@
36"OC
(6)#6Tx33'-6"
@30"OC
(5)#6Tx13'-0"
@24"OC
(5)#6Tx10'-6"@
36"OC
(6)#6Tx11'-0"
(9)#6Tx10'-0"
(6)#6Tx6'-6"@14"OC
(6)#6Tx6'-0"@
16"OC
(5)#6Tx2
1'-6"@
36"OC
(5)#6Tx10'-
6"@36"O
C
(5)#6Tx6'-
6"@36"O
C
(8)#6Tx2
7'-6"@
30"OC
(4)#6Tx6'-
6"@36"O
C
(5)#6Tx7'-
0"@36"O
C
(16)#6Tx10'-
6"@16"O
C
(7)#6Tx9'-0"
(4)#6Tx13'-
0"@24
"OC
(5)#6Tx6'-
0" (4)#6Tx6'-
0"@36"O
C11'-2"
4'-4"
8'-6"
9'-4"
#6Tx15'-
0"@24"O
C, TYP
BETW
EEN B
ANDED P
T
#6Tx15'-
0"@24"O
C, TYP
BETW
EEN B
ANDED P
T#6B
@18"O
C
#6B@18"OC
1
1
11
S4
S2
S2
S1
S3
S1
S1
S1
1. PT SLAB WHERE SHOWN ON PLAN CONSISTS OF REINFORCED AND POST-TENSIONED CAST-IN-PLACE CONCRETE SLAB. RE: PLAN FOR SLAB THICKNESS, REINFORCING AND PT. RE: PLAN FOR PT DRAPES. UNLESS NOTED OTHERWISE REINFORCING COVER DEFINED BY THE TABLE BELOW.
2. PT TENDON PROFILES TAKE PRECEDENCE OVER MILD REINFORCING ELEVATIONS. MILD REINFORCEMENT SHALL BE PLACED SUCH THAT IT DOES NOT INTERFERE WITH TENDON PROFILES.
3. ALL TENDONS AND TENDON ANCHORAGES SHALL BE FULLY ENCAPSULATED. PT SHEATHING SHALL BE CONNECTED TO ALL STRESSING, INTERMEDIATE, AND FIXED ANCHORAGES IN A WATERTIGHT FASHION IN ACCORDANCE WITH ACI 318.
4. AT COLUMN LOCATIONS, A MINIMUM OF TWO TENDONS IN EACH DIRECTION SHALL PASS OVER THE AREA ENCLOSED BY THE TIES OF THE COLUMN BELOW.
5. IN BANDED DIRECTION, TYPICAL SPACING BETWEEN TENDON GROUPS IS 1'-0" OC. SPACING MAY BE EXCEEDED WHERE REQUIRED TO SWEEP AROUND PENETRATIONS OR AS SHOWN ON PLANS.
6. IN UNIFORM DIRECTION, SPACING BETWEEN ADJACENT TENDONS SHALL NOT EXCEED 5'-0" OC. CONTRACTOR TO ENSURE THAT SPACING IS MAINTAINED WHERE TENDONS ARE REQUIRED TO SWEEP AROUND OPENINGS. UNLESS TENDON LOCATIONS ARE SPECIFICALLY DIMENSIONED, UNIFORM TENDONS MAY BE ASSUMED EQUALLY SPACED BETWEEN COLUMNS.
7. IN SLOPING AREAS, SLOPE TOP AND BOTTOM OF SLAB TO MAINTAIN SLAB THICKNESS, UNO.
8. RE: ARCH AND MEP FOR PENETRATIONS NOT SHOWN ON STRUCTURAL PLANS.
9. PRIOR TO DETAILING AND FABRICATION, VERIFY ALL ELEVATIONS AND DIMENSIONS WITH ARCHITECTURAL PLANS.
10. RE: SHEET S000-S002 FOR GENERAL NOTES AND GENERAL LEGENDS
11. RE: SHEET S003 FOR LOAD KEYS12. RE: SHEET S010-S016 FOR TYPICAL DETAILS13. RE: SHEET S162 FOR FRAMING PLAN14. RE: SHEET S162R FOR REINFORCEMENT PLAN15. RE: SHEET S162PT FOR PT TENDON PLANS16. RE: SHEET S500 FOR SCHEDULES
POST-TENSIONED CONCRETE PLAN NOTES:
AREA
2 HR FIRE RATING AND LESS
TOP REINF BANDED PT DIRECTION
1 1/2"
TOP REINF UNIFORM PT DIRECTION
1"
PT REINFORCING COVER
AREATOP REINF IN BANDED PT DIRECTION
TOP REINF IN UNIFORM PT DIRECTION
MILD REINFORCING COVER
2 HR FIRE RATING AND LESS
1" 1 3/4"
BOTTOM REINF LOWER
LAYER
1"
STUDRAIL SCHEDULE FOR RECTANGULAR COLUMNS
DESIGNATION
L1
RAILS / SIDE
RAILS / SIDE
STUDS / RAIL
STUDRAILS / COL
STUD DIAMETER
'T'
2 2781/2"
TYPICAL INTERIOR RECTANGULAR COLUMN
TYPICAL CORNER
PROVIDE SHORTER RAILS AT SLAB EDGE AS REQUIRED
45° MAX
NOTE:OPENINGS LOCATED WITHIN STUDRAILS THAT ARE NOT SHOWN ON STRUCTURAL DRAWINGS ARE TO BE APPROVED BY STRUCTURAL ENGINEER PRIOR TO INSTALLATION
NO PENETRATIONS WITHIN THIS ZONE, 36" FROM FACE OF COLUMN, UNO
MIN, TYP
2" CLR
NOTES:1. L2 > L12. RE: PLAN FOR STUDRAIL PLACEMENT3. RE: GENERAL NOTES FOR TOP AND BOTTOM CLEAR COVER
'CLR
'
COLUMN FACE
COLUMN FACE
TYPICAL STUDRAIL AT STEP
TYPICAL STUDRAILSTUD
T
L1
L2
L1
L2
L2
TYPICAL EDGE
PROVIDE SHORTER RAILS AT SLAB EDGE AS REQUIRED
L1
L2
1 1
S1 S2 TYP S2 TYP
S1 S2 TYP
SPACING
S1 S2
'CLR
' 'CLR
''CLR
'
LENGTH 'L', UNO
LENGTH 'L', UNO
S1
S2
S3
3 1/4 5
2 22181/2" 3 1/4 3 3/4
3 312121/2" 3 3
S4 4 41481/2" 2 1/4 2 1/4
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:2
3 A
M
S162RLEVEL 2 REINFORCEMENT
PLAN
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
1/8" = 1'-0"1 LEVEL 2 REINFORCEMENT PLAN
N
KEYED NOTES REINFORCEMENT PLAN
# DESCRIPTION
1 #4x5'-0"@18"OC, TYP AT CORE WALLS
3/4" = 1'-0"2 STUDRAIL SCHEDULE
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR HDR HDR HDR HDR HDR HDR HDR HDR
HDR
HDR
HDR
HDR
HDRHDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDRHDR
HDR
HDRHDR
HDRHDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDR
HDRHDRHDRHDRHDRHDR
1 2 4 6
6
7
7
A
B
D
F
H
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TRUSS
@19.2"OC
18" FLOOR TR
USS@
19.2"OC
18" FLOOR TR
USS@
19.2"OC
18" FLOOR TR
USS@
19.2"OC
18" FLOOR TR
USS@
19.2"OC
18" FLOOR TRU
18" FLOOR TRU
SS@16"OC
18" FLOOR TRU
SS@24"OC
4S410
T/SHEATHING
124'-5 3/8"
T/SHEATHING124'-5 3/8"
9 1/2" TJI 210@24"OC
9 1/2" TJI 2
10@24"OC
18" FLOOR TRU
18" FLOOR TRU
9 1/2" TJI 21
0@24"OC
9 1/2" TJI 21
0@12"OC
18" TJI 360@1
6"OC
(2)1 3/4"x9 1/2" L
VL
G
9 1/
2" TJI 210@12"OC
(2) 9
1/2" TJI [email protected]"OC
3S410
3S410
3S410
3S410
5S410
7S410
5S410
7S410
9S410
9S410
12S410
13S410
13S410
12S410
SIM
SIM
35
5
C
E
I
A.1
A.5
C.1
C.8
D.8
E.8
1311
10
8
21'-2 1/4" 20'-11 1/2" 21'-2 1/4"
22'-7"
5'-10"
95.98°30'-10 1/2"
5'-8
1/2"
30'-10 1/2"
4'-9"
19'-6"
19'-6"
2'-0"
25'-3"
44'-3"
29'-10 57/25
6"
1'-8 73/256" 6 11/256
"
20'-
3 1/
2"
19'-10 3
/4"
19'-10 3
/4"
28'-
11"
11'-0"
27'-8
31/
64"
4S410
12S410
A30
'-2"
A30
'-2"
A6'-0"
HD6
HD6
HD5
HD5
HD5
HD5
A21'-7"
HD5
A 21'-10"
A 21'-10"
A 21'-10"HD5
HD5
A18'-3"
HD5
HD5
A 21'-10"
A 6'-0"
C12'-0"
HD7
A 10'-0"
HD7
A17'-2"
A19'-2"
A19'-2"
A6'-8"
HD6
HD6
HD7
HD6
HD6
HD6
HD6
HD5
HD5
HD7HD6
HD6
HD6
HD6
HD5
HD6
HD6
HD5
HD5
W1
W1
W1
W1
W2
W2
W2
W4
W2
W3.1
W2
W4
W5
W5
W5
W5
W5.2
W5.2
W5.1
W5.1
W5
W5.1
W5.1
W5W5
W5
W5
W4
W4
W4
W4
W4
W4
W4
W2
W6.1
W6.1
W5.1
W6.1
W6.1
W2
W5.1
W5.1
W6.1
W6.1
W4
W4
W4
A4'-0"
HD6
HD6
A 6'-8" HD6HD6
A4'-10"
HD6
HD6
A21'-7"
HD5
HD5
5 1/8"x21" G
LB
(2)1 3
/4"x1
8" LVL
(2) 1 3/4"X9 1/2" LVL TYP (4) SIDES
OF SHAFT
1. FLOOR CONSTRUCTION: APA SPAN RATED 24" OC SINGLE FLOOR SHEATHING (3/4" NOMINAL THICKNESS) ON PREFABRICATED 4x2 WOOD TRUSSES AND WOOD I-JOISTS. RE: ARCH FOR MORE INFORMATION.
2. BEAM REACTIONS LESS THAN 8 KIPS ARE NOT SHOWN.3. RE: SHEETS S000-S002 FOR GENERAL NOTES AND
GENERAL LEGENDS.5. RE: SHEETS S010-S016 FOR TYPICAL DETAILS.6. RE: SHEETS S500-S501 FOR COLUMN, SHEAR WALL,
HOLDOWN, AND BASE PLATE SCHEDULES. 8. RE: SHEET S003 FOR LOAD KEYS.
FLOOR FRAMING PLAN NOTES:
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:2
6 A
M
S163LEVEL 3 FRAMING PLAN
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
1/8" = 1'-0"1 LEVEL 3 FRAMING PLAN
N
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
PRE-
ENGIN
EERED
WOOD
TRUSSES @
24"OC
PRE-
ENGIN
EERED
WOOD
TRUSSES @
24"OC
1 2 4
6
6
7
7
AA
BB
DD
F
F
H
H
PRE-ENGINEERED WOODTRUSSES@24"OC
PRE-ENGINEERED WOODTRUSSES@24"OC
PRE-ENGINEERED WOOD
TRUSSES@24"OC
PRE-ENGINEER
ED WOOD
TRUSSES@24"O
C
PRE-ENGINEER
ED WOOD
TRUSSES@24"O
C
G
G
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
2S411
3S410
4S410
(2)1 3/4"x18" LVL
(2)1 3/4"x18" LVL
3
5
5
CC
E
E
I
I
A.1
A.5
C.1
C.8
D.8
E.8
1311
10
8
21'-2 1/4" 20'-11 1/2" 21'-2 1/4"
22'-7"
5'-10"
95.98°
30'-10 1/2"
5'-8
1/2"
30'-10 1/2"
4'-9"
19'-6"
19'-6"
2'-0"
25'-3"
44'-3"
29'-10 57/25
6"
1'-8 73/256" 6 11/256
"
27'-8
31/
64"
20'-
3 1/
2"
19'-10 3
/4"
19'-10 3
/4"
28'-
11"
11'-0"
DRAG TRU
SS = 572
0 LB
DRAG TRU
SS = 664
0 LB
DRAG TRU
SS = 6830 LB
DRAG TRU
SS = 604
0 LB
DRAG
TRUSS
= 7
590
LB
DRAG
TRUSS
= 9
400
LB DRAG TRUSS
= 9350 LB
DRAG TRUSS = 10470 LB
DRAG TRUSS = 6070 LB
1S411
1S411
1S411
1S411
1S411
1S411
3S411
3S411
3S411
3S411
3S411
3S411
3S411
3S411
W4
W8x15 H
OIST B
EAM
5 1/8"x15" GL
B
GIRDER TRUSS
7S411
7S411
7S411
1. TYPICAL ROOF IS FINISHES AND INSULATION OVER 5/8" OSB/PLYWOOD ROOF SHEATHING OVER PRE-ENGINEERED WOOD TRUSSES. ATTACH ROOF SHEATHING WITH 8d@4"OC AT EDGES AND @12"OC IN FIELD, UNO.
2. RE: SHEETS S000-S002 FOR GENERAL NOTES AND LEGENDS.
3. RE: SHEET S003 FOR LOAD KEYS.4. RE: SHEETS S010-S016 FOR TYPICAL DETAILS.5. RE: SHEET S500-S501 FOR COLUMN, SHEAR WALL,
HANGER, AND HOLDOWN SCHEDULES.
UPPER LEVEL/ LOW ROOF PLAN NOTES:
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:2
7 A
M
S164ROOF FRAMING PLAN
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
1/8" = 1'-0"1 ROOF FRAMING PLAN
N
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
LEVEL 1A100'-0"
LEVEL 2 CD113'-7 1/2"
LEVEL 1100'-0"
D.8
CENTERED
#5@
12"OC
CEN
TERED
#5@12"OC
LEVEL 2 CD113'-7 1/2"
LEVEL 1100'-0"
CENTERED
#5@
12"OC
CEN
TERED
#5@12"OC
LEVEL 2 CD113'-7 1/2"
LEVEL 1100'-0"
8
CENTERED
#5@
12"OC
CEN
TERED
#5@12"OC
TYP OPENING REINF, RE: TYPICAL DETAILS
LEVEL 2 CD113'-7 1/2"
LEVEL 1100'-0"
F G
CENTERED
#5@
12"OC
CEN
TERED
#5@12"OC
LEVEL 1A100'-0"
LEVEL 2 CD113'-7 1/2"
LEVEL 1100'-0"
G
CENTERED
#5@
12"OC
CEN
TERED
#5@12"OC
6'-4"
10"
TYP OPENING REINF, RE: TYPICAL DETAILS
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:2
9 A
M
S300CORE WALL ELEVATIONS
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
3/8" = 1'-0"1 BLDG 4B SOUTH CORE - EAST ELEVATION3/8" = 1'-0"2 BLDG 4B SOUTH CORE - SOUTH ELEVATOR ELEVATION
3/8" = 1'-0"3 BLDG 4B SOUTH CORE - SOUTH STAIR ELEVATION
3/8" = 1'-0"4 BLDG 4B SOUTH CORE - WEST ELEVATION
3/8" = 1'-0"5
BLDG 4B SOUTH CORE - EASTELEVATOR ELEVATION
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
MIN GRADE BEAM DWLS - (4) #5 UNO CONTACT LAP SPICE W/ VERT PIER REINF
GRADE BEAM, RE: PLAN
OPTIONAL CONSTRUCTION JOINT
VOID FORM IF REQUIRED, RE: GENERAL NOTES
a
MINIMUM DOWEL EMBEDMENT GREATER OF 2'-0" OR CLASS B TENSION SPLICE PER GENERAL NOTES
2'-0 5/64
"
a
OPTIONAL CONSTRUCTION JOINT
T/PIER
MINIMUM DOWEL EMBEDMENT GREATER OF 2'-0" OR CLASS B TENSION SPLICE PER GENERAL NOTES
DRAPE REINF AT PIER
MULTIPLE PIER CAP
DOWELS W/ STD HOOKTO MATCH PIER REINF
T/PIER CAP
VOID FORM IF REQD, RE: GENERAL NOTES
PIER CAP REINF,RE: PLAN
1'-9 191/
256"UNO
3" CLR
BRICK VENEER, RE: ARCH
INSULATION, RE: ARCH
WOOD WALL, TYP
GYPSUM BOARD, RE: ARCH
SOG, RE: PLAN
CURB, RE: SCHEDULES FOR REINF INFO
GRADE BEAM, RE: SCHEDULES FOR REINF INFO
T/PIER
T/SOG
6"
1'-4"
10"
INSULATION, RE: ARCH
6" STUD WALL, RE: PLAN
GYPSUM BOARD, RE: ARCH
SOG, RE: PLAN
REINF STEM W/ #X BAR CONT TOP AND #X BAR VERT @ X" OC
GRADE BEAM, REINF W/ (X) #X BARS TOP&BOT AND #X TIES @ X" OC
T/PIER
T/SOG
10"
1'-0"
SOG, RE: PLAN
STUD WALL RE: PLAN AND SCHEDULE
GRADE BEAM RE: PLAN AND SCHEDULE
CONT VOID FORM
(1) #4 CONT TOP
#4 VERT @ 18" OC
RE: PLAN
T/SOG
GRID
STUD WALL RE: PLAN AND SCHEDULE
GRADE BEAM RE: PLAN AND SCHEDULE
CONT VOID FORM
(1) #4 CONT TOP
#4 VERT @ 18" OC
RE: PLAN
T/SOG
GRID GRID
INSULATION, RE: ARCH
6" STUD WALL, RE: PLAN
GYPSUM BOARD, RE: ARCH
SOG, RE: PLAN
1'-4"
MATCH VERT BARS
RE: P
LAN SOG, RE: PLAN
8'' CONCRETE CIP WALL
MAT SLAB, RE: PLAN
DRILLED PIER, RE: PLAN
CONT VOID FORM
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:3
1 A
M
S400FOUNDATION DETAILS
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS1
DRILLED PIER DETAIL AT GRADEBEAM
NTS2 DRILLED PIER DETAIL AT MULTIPLE PIER CAP
3/4" = 1'-0"3 TYP GRADE BEAM SECTION AT EXTERIOR WOOD WALL
3/4" = 1'-0"4
TYP GRADE BEAM SECTION ATEXTERIOR STORE FRONT
3/4" = 1'-0"5 GRADE BEAM SECTION AT INTERIOR WALL
3/4" = 1'-0"6
GRADE BEAM SECTION AT RAMPEDFLOOR
NTS7 ELEVATOR PIT DETAIL
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
A Permit Resubmittal 08/23/2019
A
PROGRESS PRINT 09.04.2019
SCL RIM BOARD (1 1/4" MIN WIDTH)
WALL SHEATHING EDGE NAILING EA SIDE OF JOINT,
RE: PLAN NOTES
SHEATHING AND NAILING, RE: PLAN NOTES
RE: TYPICAL BEARING WALL ELEVATION FOR ADDITIONAL INFORMATION
GAP
1/8"
(4) 8d EQUALLY SPACED
TOENAIL BLOCKING FLANGES TO FLOOR JOIST W/ 10d NAILS
JOIST SPACING
WOOD I-JOIST BLOCKING @4'-0"OC
SIMPSON A35@48"OC, UNO, AT SHEAR WALL RE: TYPICAL
SHEAR WALL NAILING SCHEDULE AND DETAILS
AT SHEAR WALL RE: TYPICAL SHEAR WALL NAILING SCHEDULE AND DETAILS
I-JOIST
T/SHEATHING
WALL SHEATHING EDGE NAILING, RE: PLAN NOTES
SCL RIM BOARD (1 1/4" MIN WIDTH)
WALL SHEATHING EDGE NAILING EA SIDE OF JOINT,
RE: PLAN NOTES
SHEATHING AND NAILING, RE: PLAN NOTES
RE: TYPICAL BEARING WALL ELEVATION FOR ADDITIONAL INFORMATION
GAP
1/8"
T/SHEATHING
I-JOIST
SIMPSON A35@48"OC, UNO, AT SHEAR WALL RE: SHEAR WALL NAILING SCHEDULE AND DETAILS
AT SHEAR WALL RE: SHEAR WALL NAILING SCHEDULE AND DETAILS
WALL SHEATHING EDGE NAILING EA SIDE OF JOINT,
RE: PLAN NOTES
AT SHEAR WALL RE: SHEAR WALL NAILING SCHEDULE AND DETAILS
SHEATHING AND NAILING, RE: PLAN NOTES
FLOOR JOIST RE: PLAN
WOOD STUD WALL RE: PLAN
RE: PLAN
T/SHEATHING
SCL RIM BOARD(1 1/4" MIN WIDTH)
PROVIDE SQUASH BLOCKING AT ALL COLUMNS/STUDPACKS, MATCH SIZE OF COLUMN/ STUDPACK BELOW
WALL SHEATHING EDGE NAILING, RE: PLAN NOTES
GYPCRETE, RE: ARCH
GAP
1/8"
RE: TYPICAL BEARING WALL ELEVATION FOR ADDITIONAL INFORMATION
SIMPSON A35@48"OC, UNO, AT SHEAR WALL RE: SHEAR WALL NAILING SCHEDULE AND DETAILS
FLOOR JOIST RE: PLAN
WOOD STUD WALL RE: PLAN
RE: PLAN
T/SHEATHING
JOIST BLOCKING @ 24" OC, W/ (4) 8d NAILS MIN
SHEATHING, CONTINUE OVER JOIST, BLOCK EDGES AS REQUIRED AT SHEAR WALLS
PROVIDE SQUASH BLOCKING AT ALL COLUMNS/STUDPACKS, MATCH SIZE OF COLUMN/STUDPACK BELOW
FLOOR EDGE NAILING, FLOOR SHEATHING TO RIMBOARD
AT SHEAR WALL RE: SHEAR WALL NAILING SCHEDULE AND DETAILS
GYPCRETE, RE: ARCH
SCL RIM BOARD (1 1/4" MIN WIDTH)
GAP
1/8"
WALL SHEATHING EDGE NAILING EA SIDE OF JOINT,
RE: PLAN NOTES
SIMPSON A35@48"OC, UNO, AT SHEAR WALL RE: TYPICAL
SHEAR WALL NAILING SCHEDULE AND DETAILS
2x6 STRONG BACK @10'OC MAX W/ (3) 0.131"x3" NAILS TO EACH TRUSSTRUSS SPACING
WOOD STUD WALL RE: PLAN
RIMBOARD
FLOOR TRUSS, BOTTOM CHORD BEARING AT WALL
RE: PLAN
T/SHEATHING
SHEATHING WHERE OCCURS
PROVIDE SQUASH BLOCKING AT ALL COLUMNS/STUDPACKS, MATCH SIZE OF COLUMN/STUDPACK BELOW
FLOOR JOIST RE: PLAN
WOOD STUD WALL RE: PLAN
RE: PLAN
T/SHEATHING
JOIST BLOCKING @ 24" OC, W/ (4) 8d NAILS MIN
PROVIDE SQUASH BLOCKING AT ALL COLUMNS/STUDPACKS, MATCH SIZE OF COLUMN/STUDPACK BELOW
FLOOR EDGE NAILING, FLOOR SHEATHING TO RIMBOARD
GYPCRETE, RE: ARCH
SCL RIM BOARD (1 1/4" MIN WIDTH)
TRUSS SPACING TRUSS SPACING
WOOD STUD WALL RE: PLAN, SHEATHING AT SHEAR WALLS ONLY
FLOOR TRUSS RE: PLAN
TOP FLANGE HANGER, RE: SCHEDULE, AT SHEAR WALLS HANGER TO BE SUITABLE FOR INSTALLATION OVER WOOD SHEATHING
RE: PLAN
T/SHEATHING
TJI CORRIDOR FRAMING, RE: PLAN
BLOCKING TRUSS @24"OC
RIMBOARD
SHEATHING RE: PLAN
AT CORRIDOR BEAMS PROVIDE FLAT 2x BLOCKING FOR FACE
MOUNT HANGER INSTALLATION, MIN WIDTH = HANGER WIDTH + 1"
TRUSS SPACING
WOOD STUD WALL RE: PLAN, SHEATHING AT SHEAR WALLS ONLY
FLOOR TRUSS RE: PLAN
RE: PLAN
T/SHEATHING
BLOCKING TRUSS @24"OC
RIMBOARD
SHEATHING RE: PLAN
AT CORRIDOR BEAMS PROVIDE FLAT 2x BLOCKING FOR FACE
MOUNT HANGER INSTALLATION, MIN WIDTH = HANGER WIDTH + 1"
TJI CORRIDOR FRAMING, RE: PLAN
TRUSS SPACING JOIST SPACING
WOOD STUD WALL RE: PLAN, SHEATHING AT SHEAR WALLS ONLY
TOP FLANGE HANGER, RE: SCHEDULE, AT SHEAR WALLS HANGER TO BE SUITABLE FOR INSTALLATION OVER WOOD SHEATHING
RE: PLAN
T/SHEATHING
TJI CORRIDOR FRAMING, RE: PLAN
RIMBOARD
SHEATHING RE: PLAN
AT CORRIDOR BEAMS PROVIDE FLAT 2x BLOCKING FOR FACE MOUNT HANGER INSTALLATION, MIN WIDTH = HANGER WIDTH + 1"
FLOOR JOIST RE: PLAN
GYPCRETE, RE: ARCH
STUD WALL, RE: PLAN
ANCHOR HOOK, RE: GENERAL NOTES AND SCHEDULE
PT CONCRETE SLAB, RE: PLAN
MASONRY VENEER, RE: ARCH
RE: PLAN
T/SLAB
B/STL
2'-10 1/8"
C5X9X1'-9" HANGER AT 4'-0" OC PROVIDE 2" LONG VERTICAL SLOT FOR ATTACHMENT TO ANGLE
V3/8"X5"X0'-5 3/4" W/ (1) 3/4"T ERECTION BOLT AND 2" LONG HORIZONTAL SLOTTED HOLE
6"
EMBED V1/2"X12"X1'-0" W/ (4) 3/4"TX6" HAS
L3/8"x3 1/2"x0'-6"
1/4
1/4
1/4
1/4
C5X9
RE: PLAN
T/SLAB
STUD WALL, RE: PLAN
ANCHOR HOOK, RE: GENERAL NOTES AND SCHEDULE
PT CONCRETE SLAB, RE: PLAN
CIP WALL, RE: PLAN
16d@8"OC WHERE WALL ABOVE FLOOR OCCURS, AT SHEAR WALL RE: SHEAR WALL NAILING SCHEDULE AND DETAILS
RE: PLAN
T/SHEATHING
GYPCRETE, RE: ARCH
SHEATHING AND NAILING, RE: PLAN NOTES. KEEP SHEATHING CONTINUOUS OVER DEMISING WALL
FLOOR TRUSS, RE: PLAN
RIM BOARD OVER EACH WALL (1 1/4" MIN)
RE: TYPICAL BEARING WALL ELEVATION FOR ADDITIONAL INFORMATION
16d@8"OC WHERE WALL ABOVE FLOOR OCCURS, AT SHEAR WALL RE: SHEAR WALL NAILING SCHEDULE AND DETAILS
RE: PLAN
T/SHEATHING
GYPCRETE, RE: ARCH
RE: TYPICAL BEARING WALL ELEVATION FOR ADDITIONAL INFORMATION
FLOOR TRUSS RE: PLAN
BLOCKING TRUSS @24"OC
SHEATHING AND NAILING, RE: PLAN NOTES. KEEP SHEATHING
CONTINUOUS OVER DEMISING WALL
RIM BOARD OVER EACH WALL (1 1/4" MIN)
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:3
3 A
M
S410FRAMING DETAILS
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS2
EXTERIOR WALL WITHPARALLEL JOISTS
NTS1
EXTERIOR WALL WITHPERPENDICULAR JOISTS
3/4" = 1'-0"3
EXTERIOR WALL WITHPERPENDICULAR TRUSS
3/4" = 1'-0"4
EXTERIOR WALL WITHPARALLEL TRUSS
3/4" = 1'-0"5
INTERIOR WALL WITHPERPENDICULAR TRUSS
3/4" = 1'-0"6
INTERIOR WALL WITHPARALLEL TRUSS
3/4" = 1'-0"7
INTERIOR WALL WITHPERPENDICULAR JOISTS
3/4" = 1'-0"8
INTERIOR WALL WITHPARALLEL JOISTS
3/4" = 1'-0"9
INTERIOR WALL WITHPERPENDICULAR JOISTS
3/4" = 1'-0"10 STRUCTURAL SLAB AT EXTERIOR GRADE BEAM
3/4" = 1'-0"11 WALL TRANSITION SECTION AT PT SLAB OPENING
3/4" = 1'-0"12
INTERIOR WALL SECTION ATELEVATOR OPENING
3/4" = 1'-0"13
INTERIOR WALL SECTION ATELEVATOR OPENING
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
PROGRESS PRINT 09.04.2019
RE: ARCH
T/PARAPET
VARIES
T/TRUSS
RE: PLAN
T/PLATE
PLYWOOD SHEATHING
WOOD STUD WALL, RE: PLAN
CONT 1 3/4"X9 1.2" LVL, FASTEN TO EA STUD W/ (2) SIMPSON SDS25600
PROVIDE SOLID BLOCKING BETWEEN EA STUD AT SHEAR WALL LOCATIONS
WOOD ROOF TRUSS, RE: PLAN
SHEATHING, TYP
WOOD TRUSS AND CLIP RE: PLAN AND TRUSS MANUFACTURER
WOOD STUD WALL, RE: PLAN
SHEATHING
SHEATHING
PARAPET BUILT INTO TRUSS, DESIGN FOR PARAPET WIND PRESSURES, H/180 DEFLECTION LIMIT. NOTE DOUBLE 2X6 MAY BE REQUIRED FOR PARAPET HEIGHTS OVER 4'.
1"3 1/2"
3 1/2"
1 1/4"
5 1/4"
1 1/4" (2) 2x10 VERT STUD AT EACH TRUSS, RE: TRUSS MANUFACTURER FOR VERT STUD TO TRUSS CONNECTION
2x12 @24"OC, FASTEN TO VERT STUD W/ (6) SIMPSON SDS25300
2x12 RIM EA END
1.17 KIPS
0.72 KIPS
0.21 KIPS
T/TRUSS
T/SHEATHING
SHEATHING
4'-8" M
AX
3'-7" MAX
ROOF SHEATHING RE: PLAN
DRAG TRUSS RE: PLAN
SIMPSON DSC5R/L-SDS3 EACH END OF SHEAR WALL, WHERE DRAG LOAD IS GREATER THAN 9500LBS, ADD (1) SIMPSON DSC5R/L-SDS3 AT CENTER OF WALL
3/4" MIN
SHEAR WALL RE: PLAN AND SCHEDULE
SHEATHING AND NAILING, RE: PLAN NOTES
FLOOR TRUSS RE: PLAN
RE: PLAN
T/SHEATHING
.
1 1/
2"
3"
3"
1 1/
2"
1 1/2"3"1 1/2"
V3/8"x6"x0'-9" W/ (4) 5/16"Tx3 1/2" LAG SCREWS AND (2) 3/8"T THRU BOLTS
V3/8"
1/4 6
1/4 6TYP
RE: ARCH
T/CHANNEL
1.5 B DECK W/ 5/8" PUDDLE WELDS AT 12/24 PATTERN AT
PERIMETER AND SIDELAP WELDS OR SCREWS @12" OC
CHANNEL, RE: PLAN
V3/8"
1/4 2-12
1/4 2-12TYP
S4115
L2x2x5/16, TYP
3/4"T A36 ROD W/ #2 CLEVIS & 3/4"T PINS EA END.
PROVIDE TRUNBUCKLE OR REVERSE THREAD ONE END
CONNECTION AT ENDS
(2) 2x STUD COLUMN AT CANOPY CONNECTIONS
RE: ARCH
T/CHANNEL
CHANNEL, RE: PLAN
1/4 33-SIDES
1/4TYP CHLTO CHL
3/8" BENT PLATE W/ (2) 3/8"Tx3 1/2" LAG SCREWS
2"
RE: ARCH
T/CHANNEL
WT, RE: PLAN
1/4 33-SIDES
1/4TYP WT TO WT
3/8" BENT PLATE W/ (2) 3/8"Tx3 1/2" LAG SCREWS
1" 2"
2"1"
WT CANOPY WALL CONNECTION CHANNEL CANOPY WALL CONNECTION
SHEATHING AND NAILING, RE: PLAN NOTES
FLOOR TRUSS RE: PLAN
RE: PLAN
T/SHEATHING
.
1 1/
2"4"
4"
1 1/
2"
1 3/4"2 1/2"1 3/4"
V3/8"x6"x0'-9" W/ (4) 5/16"T LAG SCREWS (3" MIN THREAD PENETRATION)
V3/8"
1/4 6
1/4 6TYP
RE: ARCH
T/CHANNEL
1.5 B DECK W/ 5/8" PUDDLE WELDS AT 12/24 PATTERN AT
PERIMETER AND SIDELAP WELDS OR SCREWS @12" OC
WT, RE: PLAN
V3/8"
1/4 2-12
1/4 2-12
S4115
L3x3x5/16
3/4"T A36 ROD W/ #2 CLEVIS & 3/4"T PINS EA END.
PROVIDE TRUNBUCKLE OR REVERSE THREAD ONE END
CONNECTION AT ENDS
6x6 COLUMN FROM LEVEL 2 TO LEVEL 3, RE: PLAN FOR LOCATIONS
ROOF TRUSS RE: PLAN
CONT BLOCKING TRUSS
BEARING WALL RE: PLAN AND SCHEDULE
SHEATHING RE: PLAN
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:3
4 A
M
S411FRAMING DETAILS
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
3/4" = 1'-0"2 TYPICAL ROOF DETAIL PARALLEL
3/4" = 1'-0"1 TYPICAL ROOF DETAIL
3/4" = 1'-0"3 SECTION AT ROOF DRAG TRUSS
3/4" = 1'-0"4 CANOPY DETAIL
3/4" = 1'-0"5 CANOPY CONNETIONS TO WALL
3/4" = 1'-0"6 CANOPY DETAIL
3/4" = 1'-0"7 SECTION AT ROOF TRUSS BEARING
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
A Permit Resubmittal 08/23/2019
A
PROGRESS PRINT 09.04.2019
W1
WALL MARK
NOTES:1. ALL STUD FRAMING IS DOUG-FIR LARCH No.2 OR GREATER2. ALL WALLS HAVE (2) TOP PLATES THAT MATCH STUD WALL SIZE AND GRADE, UNO3. 'WX.1' WALL MARKS REQUIRE (3) TOP PLATES AT ROOF, 'WX.2' WALL MARKS REQUIRE (3)
TOP PLATES AT LEVEL 3 AND AT ROOF.4. ALL SHEAR WALL SHALL HAVE PLYWOOD OR OSB SHEATHING, RE: SHEAR WALL SCHEDULE5. RE: PLAN FOR SHEAR WALL LOCATIONS AND EXTENTS6. RE: TYPICAL DETAILS FOR ALL NAILING REQUIREMENTS7. RE: PLAN, ARCH, AND HEADER SCHEDULE FOR HEADER AND JAMBS AT WALL OPENINGS 8. AT SIM (1) 2x6@16"OC
WALL LEVEL
WOOD STUD WALL SCHEDULE
2ND LEVEL 3RD LEVEL NOTES
STAGGERED STUD LAYOUT, DOUG-FIR LARCH No.2
W2
W3
W4 --
W5
1ST LEVEL WHERE OCCURS
W1
W2
W3
W4
W5
W1
W2
W3
W4
W5
2x4 @16"OC
W6
(2) 2x4 @8"OC (2) 2x4 @10"OC
(2) 2x4 @16"OC 2x4 @16"OC 2x4 @16"OC STAGGERED STUD LAYOUT
STAGGERED STUD LAYOUT
--
--
(2) 2x4 @10"OC (2) 2x4 @12"OC
(2) 2x6 @16"OC 2x6 @16"OC 2x6 @16"OC
(2) 2x6 @12"OC (2) 2x6 @16"OC 2x6 @12"OC
(2) 2x4 @12"OC (2) 2x4 @16"OC (2) 2x4 @16"OC
MARK TYPESIZE (IN)
B D a SUPPORT a SUPPORT
REINFORCING - TOP (T) & BOT (B)
INT. RXN SPACING MAX TYP SPACING
STIRRUPSCOMMENTS
AGB1 12 28
(4)#4T
(4)#4B#3@18"OC #3@18"OC --
A12 32
(3)#7T
(3)#7B #3@14"OC #3@14"OC
AGB3 16 32
(4)#7T
(4)#7B #3@10"OC #3@10"OC
BGB4 12 32
(4)#7T
(4)#7B#3@14"OC #3@14"OC
AGB5 14 32 (8)#4@8"OC #4@14"OC(3)#9T
(3)#9B
a SUPPORT a SUPPORT
(2)#10T CONT
(4)#10B(2)#10Tx14'-0"
(4)#6T
(8)#8B (2 ROWS)
AGB6 16 32(3)#9T CONT
(3)#9B
AGB7 14 32
BGB8A16
GB8B
INT. RXN SPACING APPLIED TO BOTH SIDES OF PIERS NEAR COL. LINE B AND C
32
(4)#9T
(4)#9B
(4)#9T CONT
(4)#9B
STD HOOK AT OUTSIDE FACE OF
SUPPORT
ADDNL TOP BARS ("B" BARS)
REINF DETAILED WITH ADJACENT SPAN
CONTINUOUS TOP REINF ("A" BARS)
SUPPORT LOCATION (DRILLED PIER)
CONTINUOUS BOT REINF ("C" BARS)
REINFORCING NOTATIONS:(4) = QUANTITY OF BARS#6 = BAR SIZET,B = TOP (T) OR BOTTOM (B) REINFORCING14'-0" = LENGTH OF BARS, ONLY PROVIDED WHERE GRADE BEAM VARIES FROM
TYPICAL REINF LAYOUT(2 ROWS) = LAYOUT BEAM REINF IN (2) EQUAL ROWS AT TOP OR BOT.(CONT) = CONTINUOUS TOP BARS
RE: GRADE BEAM SECTIONS FOR LAYOUT OF REINFORCING AND ADDNL INFORMATION.
NOTES:1. ALL REQUIRED REINFORCING IS TO BE POSITIONED IN ONE LAYER (TOP AND BOT) UNLESS
NOTED OTHERWISE IN SCHEDULE.2. WHERE GRADE BEAMS ARE TERMINATED AT THE INTERIOR OF THE BUILDING, EXTEND TOP
REINF CLASS B LAP SPLICE LENGTH INTO ADJACENT SLAB-ON-VOID IN LIEU OF PROVIDING A STD HOOK AT THE END OF THE BEAM AS SHOWN IN THE SCHEDULE.
3. PROVIDE STD. HOOK AT T&B BARS AT ENDS AND CORNERS OF GRADE BEAM4. RE: TYP DETAILS FOR GRADE BEAM INTERSECTION, STEPS, CONSTRUCTION JOINTS AND
CORNER REINFORCING DETAILS.5. AT ENDS OF GRADE BEAMS, EXTEND ALL TOP AND BOTTOM REINFORCING TO FAR EDGE OF
INTERSECTION WITH ADJACENT GRADE BEAM AND TERMINATE WITH A STD HOOK.6. WHERE CLEAR SPAN IS LESS THAN OR EQUAL TO 10'-0" CONTINUE LARGER REINFORCING OF
A, B, AND C BARS FROM ADJACENT GRADE BEAM THROUGHOUT ENTIRE LENGTH.7. STAGGER SPLICE LOCATIONS AS REQUIRED TO MAINTAIN MINIMUM CLEAR DIMENSIONS FOR TOP
AND BOTTOM BARS. CONTRACTOR TO USE MECHANICAL TENSION SPLICES IF CLEAR DISTANCE CANNOT BE MAINTAINED WITH LAP SPLICES AS REQUIRED IN THE REINFORCING LEGEND.
T/CONC
TOP REINF ("A" AND "B" BARS), RE: SCHEDULE
CAP TIE ACCEPTABLE IN LIEU OF SINGLE CLOSED STIRRUP,
ALTERNATE 90_ & 135_ HOOKS
GRADE BEAM SECTION - TYPE A
"D"
"B"
IN CURB, PROVIDE (2)#5 CONT HORIZ & #4 DWLS
W/ 180_ STD HOOK @18"OC
a a
2" RE: SCHEDULE
END SPACING
RE: SCHEDULE
MAX TYP STIRRUP SPACING
RE: SCHEDULE
END SPACING
FROM FACE OF SUPPORTFIRST STIRRUP 2" TYP
UNO
0.25L(1'-0" MIN)
L (CLEAR SPAN) L1 (CLEAR SPAN)
WHERE CANTILEVER OCCURS, EXTEND ALL REINF TO EDGE
OF CANTILEVER UNO
"C" BAR, RE: LEGEND
"B" BAR
"A" BAR
STD 90_ OR 180_ HOOKS AT BM ENDS
0""B" BAR, RE: LEGEND
"A" BAR, RE: LEGEND, LAP IN MIDDLE THIRD OF CLEAR SPAN
"C" BAR, RE: LEGEND. LAP SPLICE OVER SUPPORT.FACE OF SUPPORT
(DRILLED PIER TYP)
TYPICAL GRADE BEAM REINFORCING LAYOUT
GRADE BEAM SCHEDULE
(5)#4@12"OC #4@14"OC
(16)#4@6"OC #4@14"OC
(21)#4@4"OC#4@14"OC
GRADE BEAM LEGEND
BOT REINF ("C" BAR),RE: SCHEDULE
TYP UNO
GREATER OF0.3*L OR 0.3*L1
TYP UNO
GREATER OF0.3*L OR 0.3*L1
0"
SPLICE
CLASS A TENSION
SPLICE
CLASS ATENSION
GB1
GB2A
GB3
GB4
GB5
GB8A
GB8B
GB1
GB2B
GB3
GB4
GB5
GB8A
GB8B
T/CONC
TOP REINF ("A" AND "B" BARS), RE: SCHEDULE
CAP TIE ACCEPTABLE IN LIEU OF SINGLE CLOSED STIRRUP,
ALTERNATE 90_ & 135_ HOOKS
"D"
"B"
IN CURB, PROVIDE (2)#5 CONT HORIZ & #4 DWLS
W/ 180_ STD HOOK @18"OC
BOT REINF ("C" BAR),RE: SCHEDULE
GRADE BEAM SECTION - TYPE B
B--
--
--
PROVIDE RXN SPACING ON EITHER SIDE OF
COL. C.8/6 AND D.8/6
A
PROVIDE RXN SPACING ON EITHER SIDE OF
COL. D.8/7
(11)#4@8"OC
INT. RXN SPACING APPLIED TO BOTH SIDES OF PIERS NEAR COL. LINE B AND C
DOWELS OR ANCHOR BOLTS,RE: DRILLED PIER DETAILS
VERTICAL REINF,RE: SCHEDULE
TIES, RE: SCHEDULE
EXTEND REINFORCING TOBOTTOM OF PIER, UNO
WEATHERED CLAYSTONE
PIER MARK
PIER DIAMETER
(d)
SOCKET LENGTH
REINFORCING
VERT TIES
COMPRESSION CAPACITY (KIP)
TENSION CAPACITY (KIP)
MINIMUM DEAD LOAD (KIPS)
SHEAR RING SIZE AND SPACINGSRhxSRd@SRs
REMARKS
DRILLED PIER SCHEDULE
P1 24" 4'-0" (8) #5 #3@12" 102 45 57 --
P2 24" 7'-0" (8) #5 #3@12" 136 60 57 NOT REQUIRED
P3 24" 10'-0" (8) #5 #3@14" 170 60 57
P3 = PIER TYP - RE: PIER SCHEDULE
225K = SERVICE LOAD (UNFACTORED)
70'-0" = ESTIMATED BOT PIER ELEVATION*
*ACTUAL BOT PIER ELEVATION = ACTUAL BEDROCK ELEVATION - SOCKET LENGTH
.
a
LEGEND
225K97'-4"/70'-0"
TERMINATE ENDS OF TIES W/ STD HOOKENGAGING LONGITUDINAL REINF, OVERLAP END 6" MIN
STAGGER OVERLAPS OF ADJACENT TIES AROUND PERIMETER
OVERLAPMI
N 6"
"SRs" =
SHEA
R R
ING
SPAC
ING
SHEA
R R
INGS, R
E: S
CHED
ULE
TOTAL LENGTH
OF PIER
SOCKET LEN
GTH
, RE: S
CHED
ULE
T/WEATHEREDCLAYSTONE
T/PIER
CLR3"TIES
NOT REQUIRED
SRh
SRdP3
P3DIAMETER (d)RE: SCHEDULE
--
NOTES:1. PIERS SHALL BEAR ON WEATHERED CLAYSTONE.2. PIERS HAVE BEEN DESIGNED TO BE SUPPORTED BY A COMBINATION OF END BEARING ON WEATHERED CLAYSTONE CAPABLE OF SUPPORTING 18 KSF AND SIDE
FRICTION OF 1.8 KSF IN WEATHERED CLAYSTONE. 3. PIERS SHALL HAVE A MINIMUM LENGTH OF 23 FT AND A MINIMUM SOCKET INTO THE WEATHERED CLAYSTONE OF 3 FT.4. PIER LENGTHS SHOWN ON THE PLANS ARE FOR BIDDING PURPOSES ONLY. ACTUAL LENGTHS WILL BE DETERMINED IN THE FIELD AND WILL BE ADJUSTED PER UNIT
PRICES. RE: SPECIFICATIONS.5. PIER EXCAVATION AND CONCRETE PLACEMENT SHALL BE OBSERVED BY GEOTECHNICAL ENGINEER. RE: GENERAL NOTES.6. THE GEOTECHNICAL ENGINEER SHALL BE THE SOLE JUDGE AS TO THE SUITABILITY OF THE BEARING MATERIAL. THE GEOTECHNICAL ENGINEER HOLDS THE RIGHT TO
WAIVE THE REQUIREMENT FOR SHEAR RINGS DEPENDING ON THE CONDITIONS ACTUALLY ENCOUNTERED IN INDIVIDUAL PIER HOLES.7. SHAFTS SHALL BE DRILLED PLUMB AND STRAIGHT. RE: SPECIFICATIONS FOR TOLERANCES.8. PLACE CONCRETE USING TREMIE METHOD, PUMP, OR ELEPHANT TRUNK TO PREVENT SEGREGATION. RE: SPECIFICATIONS.9. NOT MORE THAN 3" OF WATER WILL BE ALLOWED IN ANY PIER HOLE AT TIME OF CONCRETE PLACEMENT. RE: SPECIFICATION FOR DE-WATERING REQUIREMENTS.10. RE: DRILLED PIER DETAILS FOR ADDITIONAL INFORMATION.11. WHERE PIER IS OVER-DRILLED BEYOND SPECIFIED MINIMUM SOCKET LENGTH, IT IS PERMITTED TO TERMINATE REINFORCEMENT AT THE BOTTOM OF THE SPECIFIED
SOCKET LENGTH. BUT NO LESS THAN THE BOTTOM OF THE MINIMUM SPECIFIED PIER LENGTH.
97'-4" = TOP PIER ELEVATION
6" M
AX
COVE
R3" MIN
P3
P3
P3
P3
--
NOT REQUIRED
P4 24" 7'-0" (8) #5 #3@9" 136 60 57 NOT REQUIRED INCLUDE SHEAR CAPACITY OF 43 K
COLUMN SCHEDULE
MARKFLOOR
STORY B1
STORY B2
FDN DOWELS (QTY) SIZE DWL EMBED TYPE
REMARKS
COLUMN SCHEDULE LEGENDS:
24"x24"(12) #7AT5000psiNOTE 1
24"x24" = COLUMN SIZE(12) #7A = VERTICAL REINFORCING
QUANTITY, SIZE, TIE PATTERN TYPET = SPLICE TYPE
T = CLASS B TENSION LAP SPLICEC = COMPRESSION LAP SPLICEM = MECHANICAL TENSION SPLICE
5000psi = CONC STRENGTH AT 28 DAYS
COLUMN SCHEDULE NOTES:
(4) #6COMPRESSION
12"x12"(4) #6AC5000psi
C1
--
1. RE: CONCRETE COLUMN REINFORCING DETAIL, CONCRETE COLUMN TIE PATTERN SCHEDULE, AND CONCRETE COLUMN TIE SCHEDULE FOR ADDITIONAL INFORMATION AND REINFORCING REQUIREMENTS AT COLUMN LOCATIONS.
2. RE: GENERAL NOTES FOR LAP SPLICE LENGTHS3. WHERE TWO STORY COLUMN CAGES ARE SHOWN IN
SCHEDULE, SINGLE STORY CAGES ARE ACCEPTABLE AT CONTRACTOR'S OPTION, UNO.
TIE SPACING
SIZE AND SPACING OF TIES, (INCHES)VERTICAL BAR SIZE #3 #4 #5
10 - -
12 - -
14 - -
#5
#6
#7
16 16 -#8
NOTE:1. MAXIMUM SPACING NOT TO EXCEED SPACING ABOVE OR
LEAST COLUMN DIMENSION, WHICHEVER IS LESS
4 BARTYPE A
COLUMN TIE PATTERN NOTES:1. RE: CONCRETE COLUMN SCHEDULE FOR TIE SPACING2. RE: CONCRETE COLUMN SCHEDULE FOR VERTICAL REINFORCEMENT
TERMINATE ENDS OF TIES W/ STD HOOKENGAGING LONGITUDINAL REINF, OVERLAP ENDS 6" MIN
STAGGER OVERLAPS OF ADJACENT TIES AROUND PERIMETER
TYPE B
CLR1 1/2"
1 1/2" CLR
KL A&Engineers Builders421 E. 4th StreetLoveland, Colorado 80537P: (970) 667 2426 F: (970) 667 2493
Buffalo, WY Carbondale, CO Golden, CO Loveland, CO
&
SHEET No.
2560 28th Street, Suite 200Boulder, Colorado
p: 303-442-3351
DISCLAIMER:THESE DOCUMENTS ARE PROVIDED BY COBURN ARCHITECTURE, FOR THE DESIGN INTENT OF THIS SPECIFIC PROJECT AND ONLY
THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION COORDINATION, METHODS AND MATERIALS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO THE QUALITY OF WORKMANSHIP AND MATERIALS
REQUIRED FOR EXECUTION OF THESE DOCUMENTS AND WORK OR MATERIALS SUPPLIED BY ANY SUBCONTRACTORS. ALL WORK SHALL COMPLY WITH GOVERNING CODES AND ORDINANCES. THE CONTRACTOR SHALL REVIEW AND UNDERSTAND ALL DOCUMENTS AND SHALL NOTIFY THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DRAWINGS, FIELD CONDITIONS OR DIMENSIONS.
DA
TE
PR
INT
ED
:
THE STRUCTURAL ENGINEERS SEAL ON THIS DRAWING INDICATES THAT THE INFORMATION SHOWN AND THE CALCULATIONS PERTAINING TO THAT INFORMATION HAVE BEEN PREPARED BY QUALIFIED PEOPLE UNDER THE DIRECTION OF THE ENGINEER-OF-RECORD. THE SEAL DOES NOT IMPLY RESPONSIBILITY FOR INFORMATION PREPARED BY OTHERS NOR FOR ANY INFORMATION NOT SHOWN ON THIS DRAWING AND SUCH RESPONSIBILITY IS SPECIFICALLY DISCLAIMED. ON PHASED PROJECTS, DRAWINGS THAT ARE ISSUED BUT NOT SEALED SHALL BE CONSIDERED TO BE PRELIMINARY IN NATURE AND ARE ISSUED FOR INFORMATION ONLY.
THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS ON THE PROJECT TO CLEARLY DEFINE ALL OF THE REQUIREMENTS FOR THE CONSTRUCTION. WHERE CONFLICTS OCCUR CONTACT ARCHITECT FOR CLARIFICATION. © 2019 KL&A, INC
9/5/
2019
11:
15:3
7 A
M
S500SCHEDULES
30TH & PEARL -
4 SOUTH
07.03.2019
2261 JUNCTION PLACE
BOULDER, CO
PERMIT SUBMITTAL
NTS2 WOOD STUD WALL SCHEDULE
NTS4 GRADE BEAM SCHEDULENTS1
DRILLED PIER SCHEDULE (W/ ROCKSOCKETS)
NTS3 CONCRETE COLUMN SCHEDULE
NTS5 CONCRETE TIE SCHEDULENTS6 CONCRETE TIE PATTERN SCHEDULE
ISSUED/REVISION SCHEDULE
NO. DESCRIPTION AUTHOR CHECKED DATE
A Permit Resubmittal 08/23/2019
A A
PROGRESS PRINT 09.04.2019