profile view - cdc scotland...

7
KNUCKLE BOOM CRANE ON "Z" PEDESTAL BASE LINE (/ TANK TOP EL.(+) 1600 MAIN DECK EL.(+) 6200 1ST LEVEL EL.(+) 9200 2ND LEVEL EL.(+) 12200 3RD LEVEL EL.(+) 15200 4TH LEVEL EL.(+) 18200 ROOF DECK EL.(+) 21200 MAST KNUCKLE BOOM CRANE ON "Z" PEDESTAL Great Waters Maritime L.L.C PO Box - 5980, Dubai, UAE Phone - +971 4 3884242 Fax - +971 4 3884244 www.greatwaters.ae GENERAL ARRANGEMENT PLAN (WITH 4 LEGS) CDC HERON MOPU CONFIG. CELTIC DESIGN CONSULTANTS 1:125 A0 P1048 GWM-P1048-DA-001 1/7 A 16.09.2015 AS AS PSG MAIN PARTICULARS LENGTH (HULL) = 106.40 M BREADTH = 44.40 M DEPTH = 6.6 M FRAME SPACING = 0.6 M DRAFT = 4.0 M COMPLEMENT = 50 PERSON SINGLE BERTH CABIN = 50 Nos. PROFILE VIEW 25 CABINS OUTFITTED WITH "PULLMAN BUNKS" ALLOWING UP TO 75

Upload: others

Post on 31-Oct-2019

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PROFILE VIEW - CDC Scotland Ltdcdcscotland.co.uk/wp-content/uploads/2017/11/General-Arrangement-MOPU... · mopu config. celtic design consultants 1:110a0 p1048 gwm-p1048-da-0013/7

KNUCKLE BOOM CRANEON "Z" PEDESTAL

BASE LINEEL.(±) 0

TANK TOPEL.(+) 1600

MAIN DECKEL.(+) 6200

1ST LEVELEL.(+) 9200

2ND LEVELEL.(+) 12200

3RD LEVELEL.(+) 15200

4TH LEVELEL.(+) 18200

ROOF DECKEL.(+) 21200

MAST

KNUCKLE BOOM CRANEON "Z" PEDESTAL

Great Waters Maritime L.L.C

PO Box - 5980, Dubai, UAEPhone - +971 4 3884242Fax - +971 4 3884244www.greatwaters.ae

GENERAL ARRANGEMENT PLAN(WITH 4 LEGS)

CDC HERONMOPU CONFIG.

CELTIC DESIGN CONSULTANTS1:125 A0 P1048 GWM-P1048-DA-001 1/7 A

16.09.2015

AS

AS

PSG

MAIN PARTICULARS

LENGTH (HULL) = 106.40 M

BREADTH = 44.40 M

DEPTH = 6.6 M

FRAME SPACING = 0.6 M

DRAFT = 4.0 M

COMPLEMENT = 50 PERSON

SINGLE BERTH CABIN = 50 Nos.

PROFILE VIEW

25 CABINS OUTFITTED WITH "PULLMAN BUNKS"

ALLOWING UP TO 75

Page 2: PROFILE VIEW - CDC Scotland Ltdcdcscotland.co.uk/wp-content/uploads/2017/11/General-Arrangement-MOPU... · mopu config. celtic design consultants 1:110a0 p1048 gwm-p1048-da-0013/7

VOID TANKPS

VOID TANKSB

WB TANKPS

WB TANKSB

BUFFER TANKCL

LEG WELLPS AFT

LEG WELLSB AFT

PROCESS AREAFO DB TANK

PS

PROCESS AREAFO DB TANK

SB

WB DB TANKCL

HAZARDOUSDRAIN TANK PS

WB DB TANKPS

CONTAMINATED DB TANKPS

PROCESS AREAFO DB TANK

PS

PROCESS AREAFO DB TANK

SB

PROCESS AREASLUDGE TANK

CL

PROCESS AREADIRTY OIL TANK

CL

WB DB TANKSB

PROCESS AREABILGE HOLDING TANK

SB

CLEAN DRAIN TANKSB

RECYCLING IN SECTIONFLUID TANK SB

CONTAMINATED DRAINTANK PS

COFFERDAM

COFFERDAM

AVAILABLE

AVAILABLE AVAILABLE

AVAILABLE

AVAILABLE

AVAILABLE AVAILABLE

WB DB TANKSB

DRY DB TANKSB

DRY DB TANKPS

AVAILABLE

AVAILABLE

AVAILABLE

AVAILABLE

AVAILABLE

LEG WELLPS FWD

LEG WELLSB FWDAVAILABLE

AVAILABLE

DRY DB TANKPS

DRY DB TANKSB

DRY DB TANKCL

WB DB TANKCL

TANKPS

TANKSB

DB TANKPS

DB TANKSB

WB DB TANKPS

COFFERDAM

COFFERDAM COFFERDAM

WB DB TANKSB

FO DB TANKSB

FO DB TANKPS

FO DB TANKSB

DRY DB TANKSB

DRY DB TANKPS

FO DB TANKPS

WB DB TANKCL

WB TANKPS

WB TANKSB

FRESH WATER TANKPS

FRESH WATER TANKSB

WB DB TANKPS

WB DB TANKSB

AVAILABLE

AVAILABLE

WASTE WATER TANKPS

WASTE WATER TANKSB

WB TANKPS

WB TANKSB

COFF

ERD

AM

COFF

ERD

AMAVILABLE FORTECHNICAL LOAD

CARRYING ORSLOT LIFT

Great Waters Maritime L.L.C

PO Box - 5980, Dubai, UAEPhone - +971 4 3884242Fax - +971 4 3884244www.greatwaters.ae

GENERAL ARRANGEMENT PLAN(WITH 4 LEGS)

CDC HERONMOPU CONFIG.

CELTIC DESIGN CONSULTANTS1:110 A0 P1048 GWM-P1048-DA-001 2/7 A

16.09.2015

AS

AS

PSG

INNER BOTTOM

Page 3: PROFILE VIEW - CDC Scotland Ltdcdcscotland.co.uk/wp-content/uploads/2017/11/General-Arrangement-MOPU... · mopu config. celtic design consultants 1:110a0 p1048 gwm-p1048-da-0013/7

VOID TANKPS

VOID TANKSB

WASTE WATER TANKPS

WASTE WATER TANKSB

WB TANKPS

WB TANKSB

FRESH WATER TANKPS

FRESH WATER TANKSB

FRESH WATER TANKCL

SWITCH GEAR /ELECTRICAL / SERVICE

PS

SWITCH GEAR /ELECTRICAL / SERVICE

SB

LEG WELLPS AFT

LEG WELLSB AFT

LEG WELLPS FWD

LEG WELLSB FWD

AVAILABLE

AVAILABLE

AUXILARY MACHINERY ROOMPS

AUXILARY MACHINERY ROOMSB

N₂ TANKPS

CLEAN DRAIN TANKSB

HAZARDOUSDRAIN TANK PS

CONTAMINATED DRAINTANK PS

COFFERDAM

AVAILABLE AVAILABLE

AVAILABLE AVAILABLE

AVAILABLE

AVAILABLE

AVAILABLE AVAILABLE

AVAILABLE AVAILABLE

AVAILABLE

AVAILABLE

IN SECTION FLUID TANKCL

IN SECTION FLUID TANKCL

AVAILABLE AVAILABLE

AVAILABLE

AVAILABLE

WORKSHOP

WORKSHOP

VESSEL EQUIPMENTSERVICE AREA PS

VESSEL EQUIPMENTAREA SB

STORES

STORES

FIRE WATER RESERVE TANKCL

FIRE WATER RESERVE TANKCL

TANKPS

TANKSB

WB TANKPS

WB TANKSB

FRESH WATERMAKER PLANT ROOM

PS

FRESH WATERMAKER PLANT ROOM

SB

PUMP ROOMPS

PUMP ROOMSB

AIRCOMPRESSURE

DELUGE GENSET

DELUGE GENSET

AIRCOMPRESSURE

DELUGE GENSET

PUMP ROOMCL

OIL TANK FUEL TANK FUEL TANK

OIL TANK FUEL TANK FUEL TANK

SEAW

AGE

TREA

TMEN

TPL

ANT

ROO

MM

ACH

INER

Y CO

NTR

OL

ROO

M

UP

UP

UP

UP

AVAI

LABL

EAV

AILA

BLE

N₂ GENERATOR ROOMPS

RECYCLING IN SECTIONFLUID TANK SB

BILGE

BILGE

AVAILABLE

AVAILABLE

HAZARDOUSZONE

HAZARDOUSZONE

PASSAGEWAY

PASSAGEWAY

PASSAGEWAY

PASSAGEWAY

PASS

AGEW

AY

PASS

AGEW

AY

MAIN ENGINE ROOMSB

MAIN ENGINE ROOMPS

N₂ TANKPS

N₂ GENERATOR ROOMPS

BILGE

AVILABLE FORTECHNICAL LOAD

CARRYING ORSLOT LIFT

AVILABLE FORTECHNICAL LOAD

CARRYING ORSLOT LIFT

Great Waters Maritime L.L.C

PO Box - 5980, Dubai, UAEPhone - +971 4 3884242Fax - +971 4 3884244www.greatwaters.ae

GENERAL ARRANGEMENT PLAN(WITH 4 LEGS)

CDC HERONMOPU CONFIG.

CELTIC DESIGN CONSULTANTS1:110 A0 P1048 GWM-P1048-DA-001 3/7 A

16.09.2015

AS

AS

PSG

MACHINERY DECKPLAN @ 1600 ABL.

Page 4: PROFILE VIEW - CDC Scotland Ltdcdcscotland.co.uk/wp-content/uploads/2017/11/General-Arrangement-MOPU... · mopu config. celtic design consultants 1:110a0 p1048 gwm-p1048-da-0013/7

E-GEN

3RD PARTYMESS

GALLEY

PROV. STORE

MEAT STORE

FISH STORE

VEG. STORE ROOM

TOILET

POWER

3RD PARTYPOWER BOARD

ROPE STORE

C02 ROOM

PAINT ROOM

CABLING

LOCKER

NON_SMOKINGBREAK ROOM

SMOKING

BREAK ROOM

CORRIDOR

MED`S ROOM

ELEVATOR

DECKTOILET

HOSPITAL

KNUCKLE BOOM CRANE ON"Z" PEDESTAL

KNUCKLE BOOM CRANEON "Z" PEDESTAL

3RD PARTYPOWER BOARD

BOARD

3RD PARTYPOWER BOARD

KNUCKLE BOOM CRANEON "Z" PEDESTAL

Great Waters Maritime L.L.C

PO Box - 5980, Dubai, UAEPhone - +971 4 3884242Fax - +971 4 3884244www.greatwaters.ae

GENERAL ARRANGEMENT PLAN(WITH 4 LEGS)

CDC HERONMOPU CONFIG.

CELTIC DESIGN CONSULTANTS1:110 A0 P1048 GWM-P1048-DA-001 4/7 A

16.09.2015

AS

AS

PSG

MAIN DECKPLAN @ 6600 ABL.

Page 5: PROFILE VIEW - CDC Scotland Ltdcdcscotland.co.uk/wp-content/uploads/2017/11/General-Arrangement-MOPU... · mopu config. celtic design consultants 1:110a0 p1048 gwm-p1048-da-0013/7

Great Waters Maritime L.L.C

PO Box - 5980, Dubai, UAEPhone - +971 4 3884242Fax - +971 4 3884244www.greatwaters.ae

GENERAL ARRANGEMENT PLAN(WITH 4 LEGS)

CDC HERONMOPU CONFIG.

CELTIC DESIGN CONSULTANTS1:75 A0 P1048 GWM-P1048-DA-001 5/7 A

16.09.2015

AS

AS

PSG

1ST LEVELPLAN @ 9600 ABL.

(16 PERSONS)

Page 6: PROFILE VIEW - CDC Scotland Ltdcdcscotland.co.uk/wp-content/uploads/2017/11/General-Arrangement-MOPU... · mopu config. celtic design consultants 1:110a0 p1048 gwm-p1048-da-0013/7

Great Waters Maritime L.L.C

PO Box - 5980, Dubai, UAEPhone - +971 4 3884242Fax - +971 4 3884244www.greatwaters.ae

GENERAL ARRANGEMENT PLAN(WITH 4 LEGS)

CDC HERONMOPU CONFIG.

CELTIC DESIGN CONSULTANTS1:75 A0 P1048 GWM-P1048-DA-001 6/7 A

16.09.2015

AS

AS

PSG

3RD LEVELPLAN @ 15600 ABL.

(10 PERSONS)

2ND LEVELPLAN @ 12600 ABL.

(24 PERSONS)

Page 7: PROFILE VIEW - CDC Scotland Ltdcdcscotland.co.uk/wp-content/uploads/2017/11/General-Arrangement-MOPU... · mopu config. celtic design consultants 1:110a0 p1048 gwm-p1048-da-0013/7

80 PAX CAPACITY

80 PAX CAPACITY

MUSTER AREAS

MUSTER AREAS

Great Waters Maritime L.L.C

PO Box - 5980, Dubai, UAEPhone - +971 4 3884242Fax - +971 4 3884244www.greatwaters.ae

GENERAL ARRANGEMENT PLAN(WITH 4 LEGS)

CDC HERONMOPU CONFIG.

CELTIC DESIGN CONSULTANTS1:75 A0 P1048 GWM-P1048-DA-001 7/7 A

16.09.2015

AS

AS

PSG

HELI DECKPLAN @ 21200 ABL.

TOP DECKPLAN @ 18200 ABL.