profile application imp wall panels commercial...

28
REV. SHT. DATE APPLICATION PROFILE DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS. B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE. IMP WALL PANELS COMMERCIAL - INDUSTRIAL HORIZON WALL PANEL PROFILE IMP-200 JAN 6/21 A 42" COVERAGE 4" TYP. 1 8 " INTERIOR FACING (MESA) HORIZON WALL PANEL WIDTH: 42" PROFILE: MESA/MESA INSULATION THICKNESS: 2", 3", 4", 5", 6" EXTERIOR FACING: 22ga, 24ga, 26ga INTERIOR FACING: 22ga, 24ga, 26ga AVAILABLE FINISHES: SMOOTH, LIGHT EMBOSSED/SMOOTH, LIGHT EMBOSSED INSULATION EXTERIOR FACING (MESA) VARIES SEE SHEET IMP-202 FOR WALL PANEL SIDELAP CONNECTION DISCLAIMER THE DETAILS ARE PROVIDED FOR REFERENCE AND AS A GUIDELINE TO INDUSTRY ACCEPTED PRACTICES FOR SIMPLE BUILDING CONDITIONS. THESE DETAILS DO NOT ADDRESS ALL BUILDING TYPES, CONDITIONS OR DESIGN. THE DETAILS MUST BE CHECKED FOR SUITABILITY AND MODIFIED BASED ON THE PROJECTS INTENDED USE, LOCATION, AND DESIGN LOADS. A QUALIFIED DESIGN PROFESSIONAL SHOULD BE CONSULTED TO ENSURE MATERIALS, PRODUCTS, AND DESIGN COMPLY WITH APPLICABLE CODES, REGULATIONS, AND STANDARDS. THIS INCLUDES CORRECT PLACEMENT OF SEALANTS, LOCATION OF AIR/VAPOUR BARRIERS AND PROJECT SPECIFIC DESIGN LOADS REQUIRED BY CODE TO MEET THE REQUIREMENTS FOR THE LOCAL AUTHORITES HAVING JURISDICTION. STRUCTURAL SUPPORTS AND CONNECTIONS ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY. CONSTRUCTION DRAWINGS GOVERN OVER THESE DETAILS. ARTSPAN CONTINUES TO REFINE AND IMPROVE BASED ON CHANGES TO THE INDUSTRY. ARTSPAN AND ITS AFFILIATED COMPANIES AND SUPPLIERS RESERVE THE RIGHT TO CHANGE DETAILS, SPECIFICATIONS, DESIGNS, OR PRODUCTS AT ANY TIME. PLEASE CONTACT ARTSPAN OR YOUR LOCAL REPRESENTATIVE FOR THE LATEST INFORMATION AVAILABLE. SCREW LOCATION

Upload: others

Post on 28-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

HORIZON WALL PANEL PROFILE IMP-200 JAN 6/21 A

42" COVERAGE

4" TYP.

1 8

"

INTERIOR FACING (MESA)

HORIZON WALL PANEL

WIDTH: 42"

PROFILE: MESA/MESA

INSULATION THICKNESS: 2", 3", 4", 5", 6"

EXTERIOR FACING: 22ga, 24ga, 26ga

INTERIOR FACING: 22ga, 24ga, 26ga

AVAILABLE FINISHES: SMOOTH, LIGHT EMBOSSED/SMOOTH, LIGHT EMBOSSED

INSULATION

EXTERIOR FACING (MESA)

VARIES

SEE SHEET IMP-202 FOR WALL PANEL SIDELAP CONNECTION

DISCLAIMER

THE DETAILS ARE PROVIDED FOR REFERENCE AND AS A GUIDELINE TO INDUSTRY ACCEPTED PRACTICES FOR SIMPLE BUILDING CONDITIONS. THESE DETAILS DO NOT ADDRESS ALL BUILDING

TYPES, CONDITIONS OR DESIGN. THE DETAILS MUST BE CHECKED FOR SUITABILITY AND MODIFIED BASED ON THE PROJECTS INTENDED USE, LOCATION, AND DESIGN LOADS.

A QUALIFIED DESIGN PROFESSIONAL SHOULD BE CONSULTED TO ENSURE MATERIALS, PRODUCTS, AND DESIGN COMPLY WITH APPLICABLE CODES, REGULATIONS, AND STANDARDS. THIS

INCLUDES CORRECT PLACEMENT OF SEALANTS, LOCATION OF AIR/VAPOUR BARRIERS AND PROJECT SPECIFIC DESIGN LOADS REQUIRED BY CODE TO MEET THE REQUIREMENTS FOR THE LOCAL

AUTHORITES HAVING JURISDICTION.

STRUCTURAL SUPPORTS AND CONNECTIONS ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY. CONSTRUCTION DRAWINGS GOVERN OVER THESE DETAILS.

ARTSPAN CONTINUES TO REFINE AND IMPROVE BASED ON CHANGES TO THE INDUSTRY. ARTSPAN AND ITS AFFILIATED COMPANIES AND SUPPLIERS RESERVE THE RIGHT TO CHANGE DETAILS,

SPECIFICATIONS, DESIGNS, OR PRODUCTS AT ANY TIME. PLEASE CONTACT ARTSPAN OR YOUR LOCAL REPRESENTATIVE FOR THE LATEST INFORMATION AVAILABLE.

SCREWLOCATION

Page 2: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

EDGE WALL PANEL PROFILE IMP-200A JAN 6/21 A

42" COVERAGE

INTERIOR FACING (MESA)

INSULATION

EXTERIOR FACING (FLAT)

VARIES

EDGE WALL PANEL

WIDTH: 42"

PROFILE: FLAT/MESA

INSULATION THICKNESS: 2", 3", 4", 5", 6"

EXTERIOR FACING: 22ga, 24ga, 26ga

INTERIOR FACING: 22ga, 24ga, 26ga

AVAILABLE FINISHES: EXTERIOR: SMOOTH, LIGHT EMBOSSED, HEAVY EMBOSSED. INTERIOR: SMOOTH, LIGHT EMBOSSED.

SEE SHEET IMP-202 FOR WALL PANEL SIDELAP CONNECTION

DISCLAIMER

THE DETAILS ARE PROVIDED FOR REFERENCE AND AS A GUIDELINE TO INDUSTRY ACCEPTED PRACTICES FOR SIMPLE BUILDING CONDITIONS. THESE DETAILS DO NOT ADDRESS ALL BUILDING

TYPES, CONDITIONS OR DESIGN. THE DETAILS MUST BE CHECKED FOR SUITABILITY AND MODIFIED BASED ON THE PROJECTS INTENDED USE, LOCATION, AND DESIGN LOADS.

A QUALIFIED DESIGN PROFESSIONAL SHOULD BE CONSULTED TO ENSURE MATERIALS, PRODUCTS, AND DESIGN COMPLY WITH APPLICABLE CODES, REGULATIONS, AND STANDARDS. THIS

INCLUDES CORRECT PLACEMENT OF SEALANTS, LOCATION OF AIR/VAPOUR BARRIERS AND PROJECT SPECIFIC DESIGN LOADS REQUIRED BY CODE TO MEET THE REQUIREMENTS FOR THE LOCAL

AUTHORITES HAVING JURISDICTION.

STRUCTURAL SUPPORTS AND CONNECTIONS ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY. CONSTRUCTION DRAWINGS GOVERN OVER THESE DETAILS.

ARTSPAN CONTINUES TO REFINE AND IMPROVE BASED ON CHANGES TO THE INDUSTRY. ARTSPAN AND ITS AFFILIATED COMPANIES AND SUPPLIERS RESERVE THE RIGHT TO CHANGE DETAILS,

SPECIFICATIONS, DESIGNS, OR PRODUCTS AT ANY TIME. PLEASE CONTACT ARTSPAN OR YOUR LOCAL REPRESENTATIVE FOR THE LATEST INFORMATION AVAILABLE.

SCREWLOCATION

Page 3: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WALL PANEL INSTALLATION - SEQUENCE 1 IMP-201 JAN 6/21 A

NON-SKINNING BUTYL [SL05]

EAVE/RAKE FRAMING

INTERMEDIATE FRAMING

INSIDE CORNER FLASHING

NON-SKINNING BUTYL [SL05]

BASE FRAMING

BASE TRIM [TR01-01-_T]

NON-SKINNING BUTYL [SL05]

Page 4: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WALL PANEL INSTALLATION - SEQUENCE 2 IMP-201A JAN 6/21 A

PUSH TOP OF PANEL AGAINST

UPPER FRAMING MEMBER

SET BOTTOM OF PANEL ON BASE FLASHING

NOTE:

- FIELD CUT PANEL TO DESIRED WIDTH.

Page 5: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WALL PANEL INSTALLATION - SEQUENCE 3 IMP-201B JAN 6/21 A

SECURE TOP OF PANEL

WITH CLIPS AND SCREWS

ALIGN PANEL EDGE

WITH CORNER LINE

CORNER PANEL

SECURE EDGE OF PANEL

WITH SELF-DRILLING SCREWS

PLUMB PANEL WITH LEVEL

INSTALL CLIPS AND SCREWS AT ALL

INTERMEDIATE SUPPORTS (IF APPLICABLE)

SECURE BOTTOM OF PANEL WITH CLIPS AND SCREWS

Page 6: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WALL PANEL INSTALLATION - SEQUENCE 4 IMP-201C JAN 6/21 A

MARRIAGE BEAD SEALANT (AT EAVE AND BASE)

NON-SKINNING BUTYL [SL05]PUSH TOP OF PANEL AGAINST

UPPER FRAMING MEMBER

INSTALLED PANEL

PRE-INSTALLED JOINT SEALANT

SET CLEARANCE BETWEEN PANELS

SET BOTTOM OF PANEL ON BASE FLASHING

NEXT PANEL

Page 7: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WALL PANEL INSTALLATION - SEQUENCE 5 IMP-201D JAN 6/21 A

SLIDE PANEL OVER TO FULLY

ENGAGE JOINT OF INSTALLED PANEL

INSTALLED PANEL

PUSH BOTTOM OF PANEL TO

ENGAGE JOINT OF INSTALLED PANEL

NEXT PANEL

Page 8: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WALL PANEL INSTALLATION - SEQUENCE 6 IMP-201E JAN 6/21 A

PLUMB PANEL WITH LEVEL

INSTALL CLIPS AND SCREWS AT ALL

INTERMEDIATE SUPPORTS (IF APPLICABLE)

SECURE TOP OF PANEL

WITH CLIPS AND SCREWS

INSPECT GAP TO

ENSURE TIGHT FIT

INSTALLED PANEL

SECURE BOTTOM OF PANEL WITH CLIPS AND SCREWS

Page 9: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WALL PANEL SIDELAP IMP-202 JAN 6/21 A

VISUALLY INSPECT PANEL JOINT TO

ENSURE SEAM IS EVENLY CLOSED WITH

AN APPROX. 1/8" (3mm) GAP

NOTE:

- AT STRUCTURAL GIRT USE STRUCTURAL FASTENER (FST7-5x_ - SD5-#14 x _" HW 3/8" SIDELAP)

- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.

- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.

MINIMUM (3) FASTENERS

(FST7-3x_ - SD3-#14x_")

(TYPE PER ENGINEERING DESIGN)

EXTERIOR FACE

INTERIOR FACE

WALL GIRT

(BY FRAMING SUPPLIER)

NON-SKINNING BUTYL [SL05]

WALL PANEL CLIP [CF01]

INSULATED METAL WALL PANEL

Page 10: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

PANEL BASE CONNECTION IMP-203 JAN 6/21 A

VARIES

3 8

"

CONCRETE ANCHORS (BY OTHERS)

NON-SKINNING BUTYL [SL05] WITH MARRIAGE

BEAD TO INTERIOR PANEL JOINT.

3" M

IN

.

BASE ANGLE

(BY FRAMING SUPPLIER)

1/4"x7/8" BUTYL TAPE [SL03]

BASE TRIM [TR01-01-_T]

1/8"Ø X 1/2" STAINLESS STEEL

RIVET @ 16"(406mm) O/C

COVER TRIM [TR10-01]

INSULATED METAL WALL PANEL

WALL PANEL CLIP [CF01]

MINIMUM 3 FASTENERS (FST7-3x_)

BASE SEALANT

(BY FRAMING SUPPLIER)

Page 11: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

PANEL BASE CONNECTION W/ INSULATION IMP-203A JAN 6/21 A

VARIES

CONCRETE ANCHORS

(BY OTHERS)

NON-SKINNING BUTYL [SL05] WITH MARRIAGE

BEAD TO INTERIOR PANEL JOINT.

BASE ANGLE

(BY FRAMING SUPPLIER)

BASE SEALANT

(BY FRAMING SUPPLIER)

MINIMUM 3 FASTENERS [FST7-3x_]

WALL PANEL CLIP [CF01]

INSULATED METAL WALL PANEL

COVER TRIM [TR10-01]

1/8"Ø x 1/2" STAINLESS STEEL

RIVET @ 16"(406mm) O/C

BASE TRIM [TR01-01-_T]

INSULATION

(BY OTHERS)

1/4"x7/8" BUTYL TAPE [SL03]

Page 12: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

OUTSIDE CORNER IMP-204 JAN 6/21 A

VARIES

VARIES

WALL GIRT

(BY FRAMING SUPPLIER)

FILLER ANGLE

(BY FRAMING SUPPLIER)

INSULATED WALL PANEL

THRU FASTENER

1/4-14 x _" - DP3-SQ3 [FST5-3x_]

(AS REQUIRED FOR WIND LOADING)

TO REDUCE THERMAL TRANSFER,

REMOVE INNER LAYER OF STEEL

IN THIS AREA

FIELD INSTALLED INFILL

FILLER INSULATION AS REQUIRED

(BY OTHERS)

OUTSIDE CORNER TRIM

[TR04-02-_T]

SUPPORT ANGLE

(BY FRAMING SUPPLIER)

NON-SKINNING BUTYL [SL05]

INSULATED WALL PANEL

THRU FASTENER 1/4-14 x _" - DP3-SQ3

[FST5-3x_] (AS REQUIRED FOR WIND LOADING)

NOTE:

- FIELD CUT STARTING PANEL AND ENDING PANEL AS REQUIRED AT CORNER TRANSITION.

- SEALER IN THE OUTER GROOVE OF THE WALL PANEL AND BEHIND THE OUTER TRIMS IS ONLY

REQUIRED IN WET LOCATIONS AND WHERE A REVERSE VAPOUR BARRIER IS REQUIRED.

SEE BUILDING SPECIFIC DRAWINGS.

3/16"x7/8" BUTYL TAPE [SL02]

3/16"x7/8" BUTYL TAPE [SL02]

Page 13: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

OUTSIDE CORNER IMP-204A JAN 6/21 A

VARIES

VARIES

WALL GIRT

(BY FRAMING SUPPLIER)

INSULATED WALL PANEL

THRU FASTENER

1/4-14 x _" - DP3-SQ3 [FST5-3x_]

(AS REQUIRED FOR WIND LOADING)

TO REDUCE THERMAL TRANSFER,

REMOVE INNER LAYER OF STEEL

IN THIS AREA

FIELD INSTALLED INFILL

FILLER INSULATION AS REQUIRED

(BY OTHERS)

OUTSIDE CORNER TRIM

[TR04-02-_T]

INSIDE CORNER TRIM [TR04-04-_T]

NON-SKINNING BUTYL [SL05]

INSULATED WALL PANEL

THRU FASTENER 1/4-14 x _" - DP3-SQ3

[FST5-3x_] (AS REQUIRED FOR WIND LOADING)

NOTE:

- FIELD CUT STARTING PANEL AND ENDING PANEL AS REQUIRED AT CORNER TRANSITION.

- SEALER IN THE OUTER GROOVE OF THE WALL PANEL AND BEHIND THE OUTER TRIMS IS ONLY

REQUIRED IN WET LOCATIONS AND WHERE A REVERSE VAPOUR BARRIER IS REQUIRED.

SEE BUILDING SPECIFIC DRAWINGS.

3/16"x7/8" BUTYL TAPE [SL02]

3/16"x7/8" BUTYL TAPE [SL02]

1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]@ 16"(406mm) O/C

ATTACHMENT CLIP

(BY FRAMING SUPPLIER)

Page 14: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

INSIDE CORNER IMP-205 JAN 6/21 A

VARIES

INSULATED METAL WALL PANEL

1/8"Ø X 1/2" STAINLESS STEEL RIVET

[FST4] @ 16"(406mm) O/C

THRU FASTENER 1/4-14 x _" - DP3-SQ3

[FST5-3x_] (AS REQUIRED FOR WIND LOADING)

INSIDE CORNER TRIM

[TR04-04]

INSULATED METAL WALL PANEL

NOTE:

- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.

- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.

- FIELD CUT STARTING PANEL AND ENDING PANEL AS REQUIRED AT CORNER TRANSITION.

- SEALER IN THE OUTER GROOVE OF THE WALL PANEL AND BEHIND THE OUTER TRIMS IS ONLY REQUIRED IN WET LOCATIONS

WHERE A REVERSE VAPOUR BARRIER IS REQUIRED. SEE BUILDING SPECIFIC DRAWINGS.

TO REDUCE THERMAL TRANSFER,

REMOVE INNER LAYER OF STEEL

IN THIS AREA

NON-SKINNING BUTYL [SL05]

SUPPORT ANGLE (BY FRAMING SUPPLIER)

STRUCTURAL WALL GIRT (BY FRAMING SUPPLIER)

NON-SKINNING BUTYL [SL05]

3/16"x7/8" BUTYL TAPE [SL02]

3/16"x7/8" BUTYL TAPE [SL02]

NON-SKINNING BUTYL [SL05]

Page 15: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

VARIES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

INSIDE CORNER IMP-205A JAN 6/21 A

INSULATED METAL WALL PANEL

1/8"Ø X 1/2" STAINLESS STEEL RIVET

[FST4] @ 16"(406mm) O/C

THRU FASTENER 1/4-14 x _" - DP3-SQ3

[FST5-3x_] (AS REQUIRED FOR WIND LOADING)

INSIDE CORNER TRIM

[TR04-04]

INSULATED METAL WALL PANEL

NOTE:

- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.

- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.

- FIELD CUT STARTING PANEL AND ENDING PANEL AS REQUIRED AT CORNER TRANSITION.

- SEALER IN THE OUTER GROOVE OF THE WALL PANEL AND BEHIND THE OUTER TRIMS IS ONLY REQUIRED IN WET LOCATIONS

WHERE A REVERSE VAPOUR BARRIER IS REQUIRED. SEE BUILDING SPECIFIC DRAWINGS.

TO REDUCE THERMAL TRANSFER,

REMOVE INNER LAYER OF STEEL

IN THIS AREA

1/8"Ø X 1/2" STAINLESS STEEL RIVET

[FST4] @ 16"(406mm) O/C

STRUCTURAL WALL GIRT (BY FRAMING SUPPLIER)

NON-SKINNING BUTYL [SL05]1/8"Ø X 1/2" STAINLESS STEEL RIVET

[FST4] @ 16"(406mm) O/C

3/16"x7/8" BUTYL TAPE [SL02]

3/16"x7/8" BUTYL TAPE [SL02]

NON-SKINNING BUTYL [SL05]

NON-SKINNING BUTYL [SL05]

OUTSIDE CORNER TRIM

[TR04-02-_T]

Page 16: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

DOOR HEADER IMP-206 JAN 6/21 A

1/4"

VARIES

INSULATED METAL WALL PANEL

WALL PANEL CLIP [CF01]

(2)SD3-#14X_"-HW3/8" SCREWS AT LIGHT GAUGE HEADERS

OR

(2)SD5-#14x_"-HW3/8" SCREWS AT MILL HEADERS

SD3-#14X1"-PC @ 12"(305mm) O/C

HEADER SUPPORT

(BY FRAMING SUPPLIER)

1/8"Ø X 1/2" STAINLESS STEEL

RIVET [FST4] @ 12" (305mm) O/C

CEE COVER TRIM

8" FRAMING [TR10-02-08]

10" FRAMING [TR10-02-10]

NON-SKINNING BUTYL [SL05]

NON-SKINNING BUTYL [SL05] WITH MARRIAGE

BEAD TO INTERIOR PANEL JOINT.

HEADER TRIM

[TR06-01-_T]

NOTE:

- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.

- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.

- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.

Page 17: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

DOOR JAMB IMP-206A JAN 6/21 A

VARIES

NOTE:

- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.

- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.

- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.

1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4] @ 12" (305mm) O/C

WALL GIRT (BY FRAMING SUPPLIER)

STANDARD DOOR JAMB (BY FRAMING SUPPLIER)

1/4-14 x _"-DP3-SQ3 THRU FASTENER

[FST5-3x_"] @ 24" (610mm) O/C

CEE COVER TRIM

8" FRAMING [TR10-02-08]

10" FRAMING [TR10-02-10]

NON-SKINNING BUTYL [SL05]

JAMB TRIM [TR05-01-_T]

3/16"x7/8" BUTYL TAPE [SL02]

1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]

@ 12" (305mm) O/C

INSULATED METAL WALL PANEL

1 1/4" MIN.

Page 18: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

1

4

"

VARIES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WINDOW HEADER IMP-207 JAN 6/21 A

INSULATED METAL WALL PANEL

WALL PANEL CLIP [CF01]

(2)SD3-#14X_"-HW3/8" SCREWS AT LIGHT GAUGE HEADERS

OR

(2)SD5-#14x_"-HW3/8" SCREWS AT MILL HEADERS

SD3-#14X1"-PC BASE(FLAT)

[FST6-3] @ 12"(305mm) O/C

NON-SKINNING BUTYL [SL05]

STRUCTURAL HEADER SUPPORT

(BY FRAMING SUPPLIER)

WINDOW FRAME

(BY OTHERS)

PERIMETER SEALANT

(BY OTHERS)

NON-SKINNING BUTYL [SL05] WITH MARRIAGE

BEAD TO INTERIOR PANEL JOINT.

HEADER TRIM

[TR06-01-_T]

NOTE:

- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.

- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.

- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.

Page 19: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

VARIES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WINDOW JAMB IMP-207A JAN 6/21 A

NOTE:

- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.

- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.

- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.

1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST 4] @ 12"(305mm) O/C

STRUCTURAL WALL GIRT

(BY FRAMING SUPPLIER)

STRUCTURAL WINDOW JAMB (BY FRAMING SUPPLIER)

1/4-14 x _"-DP3-SQ3 THRU FASTENER @ 24"(610mm) O/C

NON-SKINNING BUTYL [SL05]

INSULATED METAL WALL PANEL

1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4] @ 12"(305mm) O/C

3/16"x7/8" BUTYL TAPE [SL02]

JAMB TRIM [TR05-01-_T]

PERIMETER SEALANT

(BY OTHERS)

WINDOW FRAME

(BY OTHERS)

CEE COVER TRIM

8" FRAMING [TR10-02-08]

10" FRAMING [TR10-02-10]

1 1/4" MIN.

Page 20: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

1 2

"

VARIES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

WINDOW SILL IMP-207B JAN 6/21 A

NON-SKINNING BUTYL [SL05]UNDER SILL TRIM.

CEE COVER TRIM

8" FRAMING [TR10-02-08]

10" FRAMING [TR10-02-10]

WINDOW SILL (BY FRAMING SUPPLIER)

(2)SD3-#14X_"-HW3/8" SCREWS AT LIGHT GAUGE HEADERS

OR

(2)SD5-#14x_"-HW3/8" SCREWS AT MILL HEADERS

NON-SKINNING BUTYL [SL05] WITH MARRIAGE

BEAD TO INTERIOR PANEL JOINT.

WALL PANEL CLIP [CF01]

INSULATED METAL

WALL PANEL

1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]

@ 12"(305mm) O/C

3/16"x7/8" BUTYL TAPE

[SL02]

WINDOW SILL TRIM

[TR07-01-_T]

PERIMETER SEALANT

(BY OTHERS)

WINDOW FRAME

(BY OTHERS)

Page 21: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

PANEL SIDE JOINT IMP-208 JAN 6/21 A

1" MAX

varies

NOTE:

- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.

- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.

1/8"Ø X 1/2" STAINLESS STEEL RIVET

[FST 4] @ 12"(305mm) O/C

JOINT COVER TRIM [TR10-05]

1/4-14 x _"-DP3-SQ3 THRU FASTENER @ 24"(610mm) O/C

(2 PER SUPPORT)

WALL GIRT (BY FRAMING SUPPLIER)

NON-SKINNING BUTYL [SL05]

INSULATED METAL WALL PANEL

EXPANDABLE FOAM INSULATION

(BY OTHERS)

JOINT COVER TRIM [TR10-05]

3/16"x7/8" BUTYL TAPE [SL02]

1/8"Ø X 1/2" STAINLESS STEEL RIVET

[FST4] @ 12" (305mm) O/C

1" MIN

FROM PANEL EDGE

Page 22: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

VERTICAL STACK JOINT IMP-208A JAN 6/21 A

VARIES

1/2"

NOTE:

- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.

- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.

- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.

WALL PANEL CLIP

[CF01]

INSULATED METAL WALL PANEL

NON-SKINNING BUTYL [SL05]

SD3-#14x1"-PC BASE (FLAT)

[FST6-3] @ 5'-0"(1524mm) O/C

SUPPORT ANGLE WITH SEALANT

(BY FRAMING SUPPLIER)

WALL GIRT

(BY FRAMING SUPPLIER)

1/8"Ø x 1/2" STAINLESS STEEL RIVET

[FST4] @ 16"(406mm) O/C

COVER TRIM [TR10-01]

STACK JOINT TRIM [TR01-03-_T]

NON-SKINNING BUTYL [SL05]

3/16"x7/8" BUTYL TAPE [SL02]

1/8"Ø X 1/2" STAINLESS STEEL RIVET

[FST 4] @ 12"(305mm) O/C

INSULATED METAL WALL PANEL

NON-SKINNING BUTYL [SL05] WITH MARRIAGE

BEAD TO INTERIOR PANEL JOINT.

MINIMUM (3) FASTENERS [FST7-5x_"]

(TYPE PER ENGINEERING DESIGN)

NON-SKINNING BUTYL [SL05] WITH MARRIAGE

BEAD TO INTERIOR PANEL JOINT.

WALL PANEL CLIP [CF01]

Page 23: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

2

"

T

R

I

M

L

A

P

2

"

T

R

I

M

L

A

P

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

TRIM END LAP - BASE IMP-209 JAN 6/21 A

NOTE:

- RIVET OR STITCH SCREW AS NECESSARY.

FIELD NOTCH HEM(S) AS REQUIRED

2 BEADS OF NON-SKINNING BUTYL [SL05]

Page 24: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

2"

TRIM

LAP

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

TRIM END LAP - CORNER IMP-209A JAN 6/21 A

NOTE:

- RIVET OR STITCH SCREW AS NECESSARY.

FIELD NOTCH HEM(S) AS REQUIRED

2 BEADS OF NON-SKINNING BUTYL [SL05]

2"

TRIM

LAP

Page 25: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

TRIM END LAP - TWO PIECE HEAD IMP-209B JAN 6/21 A

2

"

T

R

I

M

L

A

P

2

"

T

R

I

M

L

A

P

NOTE:

- RIVET OR STITCH SCREW AS NECESSARY.

FIELD NOTCH HEM(S) AS REQUIRED

2 BEADS OF NON-SKINNING BUTYL [SL05]

Page 26: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

TRIM END LAP - TWO PIECE JAMB IMP-209C JAN 6/21 A

2"

TRIM

LAP

2"

TRIM

LAP

NOTE:

- RIVET OR STITCH SCREW AS NECESSARY.

FIELD NOTCH HEM(S) AS REQUIRED

2 BEADS OF NON-SKINNING BUTYL [SL05]

Page 27: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

TRIM END LAP - SILL IMP-209D JAN 6/21 A

2

"

T

R

I

M

L

A

P

2

"

T

R

I

M

L

A

P

NOTE:

- RIVET OR STITCH SCREW AS NECESSARY.

FIELD NOTCH HEM(S) AS REQUIRED

2 BEADS OF NON-SKINNING BUTYL [SL05]

Page 28: PROFILE APPLICATION IMP WALL PANELS COMMERCIAL ...artspaninc.com/wp-content/themes/ArtSpan/downloads/Art...DATE REV. PROFILE APPLICATION DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP WALL PANELS COMMERCIAL - INDUSTRIAL

TRIM END LAP - SILL IMP-209E JAN 6/21 A

1

2

3

4

5

1

2

3

4

5

TRIM INSTALLATION SEQUENCE:

INTERIOR JAMB TRIMS

INTERIOR HEAD TRIM WITH TABS BENT DOWN, NOTCHED

SILL TRIM WITH TABS BENT UP, NOTCHED

EXTERIOR JAMB TRIMS

EXTERIOR HEAD TRIM

EXTERIOR JAMB TRIM

EXTERIOR HEAD TRIM

INTERIOR HEAD TRIM W/ TABS BENT DOWN

SILL TRIM WITH TABS BENT UP

INTERIOR JAMB TRIM

NON-SKINNING BUTYL[SL05]

URETHANE POLYSEAL [SL06]

URETHANE END DAM

FIELD CUT/NOTCH CAP TRIM AT

CORNERS TO ALLOW FOR LAP

FIELD CUT/NOTCH CAP TRIM AT

CORNERS TO ALLOW FOR LAP

EXPOSED SEALANT (BY FRAMING SUPPLIER)