products for regenerationmegagencostarica.com/wp-content/uploads/2018/06/re... · best choice of 01...
TRANSCRIPT
Products for Regeneration
The future is already here.
Volume RE C1.0
Best choice of Bone Graft Material 01
02 Best selection for Sinus graft
18MICA kitTMCrestal approach
Auto-MaxTM
Autogenous Bone Harvester06
13Mega-Oss BovineTMXenograft
12Mega-OssTMAllograft
14Mega-TCPTMSynthetic
15Bone PlusTMSynthetic
Ideal Ridge Reconstruction
24MILA kitTMLateral approach
0304
Best combination for narrow ridge
GBR membrane for ideal regeneration
29
51 i-GenTM
Thor& BonEx kitTM
Ideal Ridge Reconstruction
Best choice of Bone Graft Material
01
Auto-MaxTM
Autogenous Bone Harvester
Mega-Oss BovineTMXenograft
Mega-OssTMAllograft
A
A
Mega-TCPTMSynthetic
Bone PlusTMSynthetic
Auto-MaxTM
AutogeneousBone Harvester
Auto-MaxTM
Description Ref.C
Auto-Max AM2535 Ø2.5~Ø3.5/Stopper
AM6070 Ø6.0~Ø7.0/Stopper
AM4050 Ø4.0~Ø5.0/Stopper
AM5060 Ø5.0~Ø6.0/Stopper
6 | 7MEGAGEN Implant
Auto-MaxTM
Design Concept
Easy and Fast Insertion
Stopper
4mm Stop
Auto-Max
Ø5
How to use
[e.g.]
Ref. Code Diameter(Ø) Ref. Code Diameter(Ø)4mm
Ø3.5 Ø5.0 Ø6.0 Ø7.0
Products
8 | 9MEGAGEN Implant
Auto-MaxTM
Clinical case 1
Clinical case 2
Bone graft materials
Bone graft materials
Allograft Xenograft
| 11MEGAGEN Implant
Bone graft materials
We understand your CONCERNS about bone graft materialsso we have prepared All options for ideal regeneration.
world-class qualitycompetitive prices.
particle sizehigher interconnected porosity
MegaGen’s suggestion for
Bone Graft Material
Synthetic Synthetic
Allograft
Cancellous Powder (60%) Cortical Powder(40%)
Description Ref.C
Mega-Oss MOB025 0.25cc
MOB050 0.5cc
MOB100 1.0cc
12 | 13MEGAGEN Implant
Bone graft materialsXenograft
Superior porous structure
No crystallization with standard fusion temperature
The new gold standard for Xenograft
proof of High multiporous structures
Description Ref.C
Mega-Oss Bovine
MBOV050 0.5cc
MBOV100 1.0cc
Synthetic
(100% -TCP, Tri Calcium Phosphate)
New bone formation(%)
4 weeks 8 weeks
Description Ref.C
Mega-TCP MTCP025 0.25g
MTCP050 0.5g
14 | 15MEGAGEN Implant
Bone graft materials
Bone PlusTM
Group N Mean
Bone PlusTM 5 21.5±2.75
5
5
5
Bone PlusTM
[x60]Micro-pore
[x5000]
Synthetic
(BCP, Biphasic Calcium Phosphate)Description Ref.C
BCP EAGLE EYE
MGSB0802 0.25gMGSB0805 0.50gMGSB0810 1.00g
BCP BULLS EYE
MGSB1005 0.50gMGSB1010 1.00g
Best selection for Sinus graft02
MICA kitTMCrestal approach
MILA kitTMLateral approachCreessttaall aapppppprrooacch LLaateraal approachpppprrooacchh
by Samuel Lee, DDS. MS
Class : High and WideClass : Low and Wide
Short and Wide Implant (5 ~ 7mm)
Class : High and Narrow Class : Low and Narrow
MICA Kit MILA Kit
Cl Hi h d Wid
MMIC
MICA Kit
Crestal approach
MICAkitTM
(MegaGen Implant Crestal Approach Kit)mplant Crestal Approach Kit)MICA kitTM
[REV.04] Ref.C
SGIS3000
18 | 19MEGAGEN Implant
MICAkitTM
1. Cleansibility
3. Repeated use
4. Cutting capability
· Innovation of Samuel Lee’s Internal Sinus Graft System REV.04 · Combined function of Diamond Drill and Reamer Drill
Express Bur
2. Safety
2 4 5 6 8
D
2
D
ASBE Trephine Bur - Scale 2:1
Diameter (D) Length (mm) Ref. C
Point Trephine Bur - Scale 2:1
Diameter (D) Length (mm) Ref. C
2
Mushroom - Scale 2:1Diameter (D) Length (mm) Ref. C
Hand Driver - Scale 2:1
Type Length (mm) Ref. C
| 21MEGAGEN Implant
MICAkitTM
D
Cobra - Scale 1:1
Diameter (D) Length (mm) Ref. C
Spreader & Condenser - Scale 1:1
Diameter (D) Length (mm) Ref. C
SSC3828
Express Bur - Scale 2:1
Diameter (D) Length (mm) Ref. C
How to use – Crestal approach
22 | 23MEGAGEN Implant
MICAkitTM
Clinical case 1
Clinical case 2
MILA kitTM [REV.01]
Lateral approach
MILAkitTM
(MegaGen Implant Lateral Approach Kit)en Implant Lateral Approach Kit)
Ref.C
KLSCN3000
24 | 25MEGAGEN Implant
MILAkitTM
How to use – Lateral approach
Diameter (D) Length (mm) Ref.C
1. Point Trephine Bur | Scale 2:1
Diameter (D) Length (mm) Ref.C
1
2. Lateral Trephine Bur | Scale 2:1
Diameter (D) Length (mm) Ref.C
3. Window Opener | Scale 2:1
1
D
1
D
26 | 27MEGAGEN Implant
MILAkitTM
Diameter (D) Length (mm) Ref.C
4. Express Bur | Scale 2:1
Diameter (D) Length (mm) Ref.C
5. Membrane Elevator | Scale 1:1
1
D
Clinical case
28 | 29MEGAGEN Implant
MILAkitTM
BonEx kitTM
Thor
03 Best combination for thin ridge
Ref.C
DMT-THOR-W
DMT-THOR-R
DMT-THOR-TSITG
Thor
< Simple >
< Strong >
1. Simple & Strong
Why Thor?
Measurements of vibration wave transmitted to the tips
Devices usedMeasurements of Tip End
Vibration Frequency
Thor 28.18 kHz
FootSwoch free Boost on ErrorFootSwoch Lock Boost off
: On & Off, Foot switch, Power BoostToo many buttons & controllers
Measurement of vibration frequency at the end of saw
End of saw
OT6 Tip
Smart ThorBS01 Tip BS01 Tip
Company A Company B Company C
BS01 Tip
100
150(mv)
50
0
Vibrator wave
| 31MEGAGEN Implant
Thor & BonEx kitTM
6
8
4
2. Specially Designed Saw for Ridge Splitting
Calibrations
Extremely Thin
Saw compatability with other piezo machines
Brand Thickness
Thor 0.36mm
Company Product
3. Perfect match with AnyRidge Implants
4. Economical
Only ‘One’ Ridge Splitting Case can cover the cost of a Thor!
AnyRidge, Thinking Man’s Privilege
2 mm osteotomy guides
Sawing with Thor to the depth of implant length
2.3mm
Tapered body works as an
Narrow platform gives no
Knife Threads make inser-tion easier, but have excel-
0.36mm
2mm
32 | 33MEGAGEN Implant
Thor & BonEx kitTM
Ref. C Diameter Length(mm) Marking line(mm)
13
Handpiece connector
Expander
Chisel and Handle
Chisel (TCMSC403)Chisel (TCMSC403)
Ratchet ext.option
connector
TANR
ES
Rach
et ex
t. (T
ANHC
L)
Lanc
e dril
l (M
GD10
0L)
TANH
CS
TANH
CU
Procedures of Ridge Split Technique
Indications
Ridge Splitting techniques may be used in any cases presenting a narrow ridge. Single implant or limited space cases however, of-fer less room for explansion.
Incision
Incision line is recommended to be at the center of remaining keratinized tissue.
Full thickness or Full-to-partial thickness
34 | 35MEGAGEN Implant
Thor & BonEx kitTM
Drilling
Now drill the desired position and axis of implant.
Chiseling (optional)If the crest is less than 2 mm, it’s
Sawing
Sawing starts from the center of ridge.
Try to maintain lingual bone thicker than buccal to expand thin ridge buccally
Expanding with BonEx kit (optional)
When the wider inside, slow expansion with BonEx kit is recommended.
Bone graft & Membrane
any kind of bone graft material. Resorbable membrane is recommendable for better bone
One stage or two stage approach can be chosen according to the conditions, but it is
successful result before trying one stage surgical approach.
Implant placement
When the ridge is expanded adequately or has
36 | 37MEGAGEN Implant
Thor & BonEx kitTM
CaseⅠ. Mandibular Posterior
Clinical case
38 | 39MEGAGEN Implant
Thor & BonEx kitTM
6 wks
4.5 mns
4 mns
CaseⅡ. Mandibular Posterior
| 41MEGAGEN Implant
Thor & BonEx kitTM
42 | 43MEGAGEN Implant
Thor & BonEx kitTM
CaseⅢ. Maxillary premolar
44 | 45MEGAGEN Implant
Thor & BonEx kitTM
CaseⅣ. Extremely thin mandibular posterior
7
46 | 47MEGAGEN Implant
Thor & BonEx kitTM
CaseⅤ. Maxillary lateral incisor case
48 | 49MEGAGEN Implant
Thor & BonEx kitTM
110105 110525 110722
Thor & BonEx kitTM
i-GenTM
04 GBR membrane for ideal regeneration
Description Ref.C
i-Gen IG1W4509 Single Atype SmallIG1W5510 Single Atype RegularIG1W6511 Single Atype WideAANFAL3510 Flat Abutment 1mm Cuff [AnyRidge]AANFAL3520 Flat Abutment 2mm Cuff [AnyRidge]AANFAL3530 Flat Abutment 3mm Cuff [AnyRidge]FA3515 Flat Abutment 1mm Cuff [AnyOne]FA3525 Flat Abutment 2mm Cuff [AnyOne]FA3535 Flat Abutment 3mm Cuff [AnyOne]FCS3510 Cover ScrewFHA402 Healing Abutment H=2,5 mmFHA403 Healing Abutment H=3,5 mmTCMHDS1600TCMHDL1600
Design Concept
Various height of Healing abutment and Cover screw should be prepared to allow a one or two phase surgical approach according to the situation.
>2.5mm horizontal extensionneeded to make >2mm labial bone after remodeling
Lingual Extension should be considered for a large defect
Need to have at least of space above
the platform of a fixture: Make this space with a pre-existing abutment, eg, Flat abutment...
>100°blunt anglewith bevel should be made to avoid soft tissue irritation.
shrinkage will occur after removal of membrane!
should be adapted to the bone.
0.5~ 1.0mm
Apical skirt
Ideal regeneration line
1mm 2222222222mmmmmmmmmmmmmmmmmmm
52 | 53MEGAGEN Implant
i-GenTM
How to use
Ideal + Regeneration membrane i-Gen membrane
maxilla
mandible
i-GEN membrane
Dimension
CodePL(Proximal Length)
BW(Buccal width)
BL(Buccal Length)
BD(Buccal Distance)
A1 A2 A3 4 9 11
4 11
4 11 11
B1 B2 B3 5 9 11
11 11
9 13 11
C1 C2 C3 5 9 11
11 11
9 13 11
i-Gen membrane has 12 different size and shapes.
Which i-Gen?
54 | 55MEGAGEN Implant
i-GenTM
Clinical case
CaseⅠ. Mandibular premolar
56 | 57MEGAGEN Implant
i-GenTM
CaseⅡ. Maxillary premolar
58 | 59MEGAGEN Implant
i-GenTM
CaseⅢ. Mandibular incisor area
Full package
| 61MEGAGEN Implant
i-GenTM
Auto-MaxTM
Mega-OssTM
Mega-Oss BovineTM
Mega-TCPTM
Bone PlusTM
MICAkitTM
MILAkitTM
Thor & BonEx kitTM
i-GenTM
Regeneration
Gangnam Office 5F MegaGen Tower, 607 Seolleung-ro, Gangnam-gu, Seoul, Korea T +82-1566-2338 Head Office 472 Hanjanggun-ro, Jain-myun, Gyeongsan, Gyeongbuk, Korea T +82-1544-2285
www.imegagen.com