product support v1.1. requirements download and install ilm on a pc that never had smart system...

12
Intermec License Manage (ILM) Training Product support V1.1

Upload: destiney-allgood

Post on 30-Mar-2015

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

Intermec License Manage(ILM) Training

Product supportV1.1

Page 2: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

RequirementsDownload and install ILM on a PC that never

had Smart System installed or had any attempt of Smart System installed.

ftp://epsfiles.intermec.com/eps_files/SWFiles/00003040_ILMSetup.exe

Installation requires a reboot of the PC.

Page 3: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

License creation steps

1- Import license

2- Add devices

3- Create license bundle

4- Export xml fileand print ScanNgo Bar Code5- Add more units to an export XML or to ScanNgo Bar Code

Page 4: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

Import License

The License ID is part of an email received from [email protected]

The count should be changed to the amount of licenses you want to use.

Go to Tools, Licenses, Import LicenseEnter the Activation IDChange the Count

Page 5: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

Import LicenseExpanding the Licenses folder will show all the License IDs and Names, etc.

Page 6: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

Add Devices The devices that connect with Active Sync or WMDC will show up automatically in Devices

Unassigned. New folder can be created . Copy and paste units from one folder to the other, one unit at a time.

Page 7: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

Add Device from a .csv fileYou can also add devices from an Excel .csv

fileThe format is Comma Separated ValuesThere should not be any space at the end of

the data. Open the file with Notepad to proof the data.

Good

Bad

There will be no diamond shape at the end of the Device ID

Page 8: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

Add Devices from a .cvs file

Page 9: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

License one deviceYou can right click on a device Add License

Page 10: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

License BundleThe License Bundle will create an xml file

that can be dropped in the Smart System/ssconfigdir folder

Right click on License Bundle folder, create New License Bundle

Choose the License ID that you want to export

Give it a name

Page 11: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

Export xml file and/or Print barcode

Page 12: Product support V1.1. Requirements Download and install ILM on a PC that never had Smart System installed or had any attempt of Smart System installed

Add more units to an export XML or

to ScanNgo Bar CodeGo to License BundlesRight click on the License Bundle Name and EditChoose the license typeChoose the activation IDChoose the devices folderCheck the devicesYou can keep the same name, the xml and the pdf

file will have all the units in the file (previous and new units)