DRYAIR INC. 606 Highway Drive, St.Brieux, SK., Canada, SOK 3V0 Tel: (306) 275-4848, 1-888-750-1700, Fax: (306) 275-4664 E-mail: [email protected] Web: www.dryair.ca DRYAIR INC. 1095 N. Main Street, Bowling Green, Ohio, USA, 43402 Tel: (419) 354-8546, 1-866-354-8546, Fax: (419) 354-9706 E-mail: [email protected] Web: www.dryair.us 2100-0900 050802 US-UK Product Specs Central Heating Module Model 2100-0900 Burner .....................................- Two stage, Diesel fuel/#1 or 2 heating oil, 85% efficient Input capacity ......................- 896,000 BTU/H, 260 KW/H Output capacity ...................- 761,600 BTU/H, 221 KW/H Fuel consumption ................- 6.4 US GPH, 24.2 LPH, 20.7 KG/H Weight .....................................- Dry - 2,800 LB., 1,270 KG Wet - 4,100 LB., 1,860 KG Electrical .................................- Single phase, 115/230 V, 60 Hz, 30 Amps Loading - standard ..................- Forklift pockets on all sides Heat exchanger.......................- Water jacket / fire tube type ............................................- Fluid volume - 45 US Gal., 170 L ............................................- Fluid temp. range - 120°F to 200°F, 49°C to 93°C Fuel tank .................................- Welded steel ............................................- Fuel capacity - 187 US GAL., 708 L ............................................- 29 hrs operating range at full output Climate control system ...........- Maintains optimum burner reliability and effiiciency at a full range of ambient temperature conditions. Assures system start-up and operation in all conditions. Before system start-up ....Pre-heater .......................- 4000 Watt electric circulation heater, 230V, preheats heat exchanger glycol before system start-up. During system operation ....Fuel heater ......................- Automatically maintains set fuel temperature. Fluid (hot glycol)-to-fluid (fuel) heat transfer. ....Combustion air heater ....- Automatically maintains set combustion air temperature. Fluid (hot glycol)-to-air heat transfer utilizing a heat transfer coil. Control & monitoring ...............- Pump & temperature controls. Full gauge panel showing circulation fluid temperatures & pressures, fuel pressures and 8-light system operation feature for easy system troubleshooting. Internal fluid circulation system Basic features......................- Atmospherically vented & low pressure, single supply & return, adjustable fluid temperature control, auto pressure by- pass for pump protection and variable flow demands, auto temperature bypass for heat exchanger protection. Circulation pump .................- RPM - 2900 ............................................- 2 HP., 1.5KW ............................................- Flow - 80 US GPM @ 30 P.S.I., 16 M³/HR @ 21 M W.C. Primary circulation ...............- Fluid circulation lines - 2”, 50 MM ............................................- Ball valves - 2”, 50 MM ............................................- Kamlock quick couplers - 2", 50 MM Heat transfer fluid (HTF) .....- Non-toxic propylene glycol / water mixture, freeze protected. Lock-out package ................- Locks out primary “supply” & “return” fluid circulation valves and control panel Optional Transport trailer Generator ............................- Diesel Specifications Features Diesel / light oil fired system Temperature control and fuel usage is automatic. includes unique “Climate Control” system which ensures efficient and reliable burner operation in all conditions Compact and portable design for easy positioning on the work site. All system operation is controlled and monitored from the central heating module control panel 8-light system operation feature for easy system troubleshooting. Fluid circulation system is low pressure and atmospherically vented. There is no chance of an explosion or line burst due to pressure build-up. No special boiler certification is required to operate the system. Quick-connect hose couplers , “no- drain” fluid lines and a “rapid air elimination” feature ensures quick setup-and-go operation. A transport trailer is available and is specifically designed to carry the Dryair 2100-900 central heating module. Trailer has a built-in lock box for enclosing an optional portable generator. Add an optional diesel-powered genset for complete self-contained operation on a non-powered site. Conforms to most special job requirements due to its modular nature. 98" 79" 57" 64"

Upload: others

Post on 09-Jan-2022

3 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Product Specs Central Heating Module - dryair.ca

DRYAIR INC. 606 Highway Drive, St.Brieux, SK., Canada, SOK 3V0 Tel: (306) 275-4848, 1-888-750-1700, Fax: (306) 275-4664 E-mail: [email protected] Web: www.dryair.ca

DRYAIR INC. 1095 N. Main Street, Bowling Green, Ohio, USA, 43402 Tel: (419) 354-8546, 1-866-354-8546, Fax: (419) 354-9706E-mail: [email protected] Web: www.dryair.us

2100-0900 050802 US-UK

Product Specs

Central Heating ModuleModel 2100-0900

Burner .....................................- Two stage, Diesel fuel/#1 or 2 heatingoil, 85% efficient

Input capacity ......................- 896,000 BTU/H, 260 KW/HOutput capacity ...................- 761,600 BTU/H, 221 KW/HFuel consumption ................- 6.4 US GPH, 24.2 LPH, 20.7 KG/H

Weight .....................................- Dry - 2,800 LB., 1,270 KG Wet - 4,100 LB., 1,860 KG

Electrical .................................- Single phase, 115/230 V, 60 Hz, 30 Amps

Loading - standard ..................- Forklift pockets on all sidesHeat exchanger.......................- Water jacket / fire tube type

............................................- Fluid volume - 45 US Gal., 170 L

............................................- Fluid temp. range - 120°F to 200°F, 49°Cto 93°C

Fuel tank .................................- Welded steel............................................- Fuel capacity - 187 US GAL., 708 L............................................- 29 hrs operating range at full output

Climate control system ...........- Maintains optimum burner reliability andeffiiciency at a full range of ambienttemperature conditions. Assures systemstart-up and operation in all conditions.

Before system start-up....Pre-heater .......................- 4000 Watt electric circulation heater,

230V, preheats heat exchanger glycolbefore system start-up.

During system operation....Fuel heater......................- Automatically maintains set fuel

temperature. Fluid (hot glycol)-to-fluid(fuel) heat transfer.

....Combustion air heater ....- Automatically maintains set combustionair temperature. Fluid (hot glycol)-to-airheat transfer utilizing a heat transfer coil.

Control & monitoring ...............- Pump & temperature controls. Full gauge panel showing circulation fluidtemperatures & pressures, fuel pressuresand 8-light system operation feature foreasy system troubleshooting.

Internal fluid circulation systemBasic features......................- Atmospherically vented & low pressure,

single supply & return, adjustable fluidtemperature control, auto pressure by-pass for pump protection and variableflow demands, auto temperature bypassfor heat exchanger protection.

Circulation pump .................- RPM - 2900............................................- 2 HP., 1.5KW ............................................- Flow - 80 US GPM @ 30 P.S.I., 16 M³/HR

@ 21 M W.C.Primary circulation...............- Fluid circulation lines - 2”, 50 MM............................................- Ball valves - 2”, 50 MM ............................................- Kamlock quick couplers - 2", 50 MMHeat transfer fluid (HTF) .....- Non-toxic propylene glycol / water

mixture, freeze protected.Lock-out package ................- Locks out primary “supply” & “return” fluid

circulation valves and control panelOptional

Transport trailerGenerator ............................- Diesel

Specifications

Features• Diesel / light oil fired system• Temperature control and fuel usage is automatic. • includes unique “Climate Control” system which

ensures efficient and reliable burner operation in allconditions

• Compact and portable design for easypositioning on the work site.

• All system operation is controlled andmonitored from the central heatingmodule control panel

• 8-light system operation feature foreasy system troubleshooting.

• Fluid circulation system is lowpressure and atmospherically vented.There is no chance of an explosion orline burst due to pressure build-up.No special boiler certification isrequired to operate the system.

• Quick-connect hose couplers , “no-drain” fluid lines and a “rapid airelimination” feature ensures quicksetup-and-go operation.

• A transport trailer is available and isspecifically designed to carry theDryair 2100-900 central heatingmodule.

• Trailer has a built-in lock box forenclosing an optional portablegenerator.

• Add an optional diesel-powered genset for complete self-containedoperation on a non-powered site.

• Conforms to most special job requirements due to its modular nature.

98"

79"

57"

64"