2 T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk
SETAFLASH SERIES 8 ACTIVECOOL CLOSED CUP TESTER (FLASH/NO FLASH & RAMP MODES) ASTM D3278; ASTM D3828; ASTM D7236; ASTM E502; IP 523; IP 524; IP 534; IP 303 (obs); ISO 3679; ISO 3680
• Flash/noflash&rampmode• Temperaturerangeof-20°Cto130°C(-4to266°F)• Smallsamplesize,2or4ml• CorrosionResistantcupoption• Electricignitor(withgasoption)• Automaticdippingandflashdetection• ActiveCoolelectronicPeltiercooling• 64Testmemory&RS232interface• °Cor°Ftemperaturedisplay
MULTIFLASH AUTOMATIC MULTI-METHOD FLASH POINT TESTERSPENSKY-MARTENS; ABEL; TAG; SMALL SCALE
• HighlyautomatedlowcostModularSystemwithin-builtsafety• Strictconformitytotestmethods• Fastandreliableperformance• GasorElectricIgnition• Temperaturein°Cor°F
SETAFLASH SERIES 3 ACTIVECOOL (RAPID EQUILIBRIUM AND RAMP TESTS) ASTM D3278; D3828; D7236; IP 303 (Obs); IP 523; IP 524; IP 534; ASTM E502; ISO 3679; ISO 3680
• Sub-AmbientTestsandRapidCoolDown• Temperaturerange10to135°C(50to275°F)• RapidEquilibriumandRamptests• CorrosionResistantoption• 1MinuteFlash/NoFlashandActualFlashPoint• 2/4mlSampleSize
SetaPartNo: 82100-0 82150-0 82000-0TemperatureRange: Air:10to130°C(50to266°F)
WaterAssisted:-20to130°C(-4to266°F)Air:10to130°C(50to266°F)WaterAssisted:-20to130°C(-4to266°F)
Ambient+5to300°C(Ambient+9to572°F)
TestModes: RapidEquilibriumandRamp RapidEquilibriumandRamp RapidEquilibriumandRampSampleSize: 2or4mlaccordingtomethod 2or4mlaccordingtomethod 2or4mlaccordingtomethodTestDuration,RapidEquilibriumMode:
1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes
1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes
1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes
TestDurationRampMode: Typically7minutes Typically7minutes Typically7minutesCupmaterial: Aluminium Corrosionresistingsteel AluminiumHeating/CoolingMethod: PeltierCell PeltierCell CeramicPad,ForcedAir(post-testcooldown)Size/weight: 30x34x38cм/8kg 30x34x38cм/8kg 30x34x38cм/8kg
SetaPartNo: 33200-2 33250-2 33000-0 30000-0TemperatureRange: 10to130°C(50to266°F) 10to130°C(50to266°F) Ambientto300°C Ambientto300°C (0to300°Cwith13870-0) (0to300°Cwith13870-0)TestModes: RapidEquilibriumandRamp RapidEquilibriumandRamp RapidEquilibriumandRamp RapidEquilibrium
SampleSize: 2or4mlaccordingtomethod 2or4mlaccordingtomethod 2or4mlaccordingtomethod 2or4mlaccordingtomethodTestDuration,RapidEquilibriumMode:
1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes
1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes
1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes
1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes
RampRate: 2°C/minramp 2°C/minramp 2°C/minrampCupmaterial: Aluminium Corrosionresistingsteel Aluminium AluminiumSize/weight: 26x28x26cm/5kg 26x28x26cm/5kg 26x28x26cm/4kg 26x28x26cm/4kg
82000-0➔
33200-2➔
34000-0+34100-2➔
81000-2➔
SetaModel: 34100-2 34200-0 34400-0 34700-0
Method: Pensky-Martens Abel TAG SmallScale
CupType: ClosedCup ClosedCup ClosedCup ClosedCup
Mode: ProcedureA,B,C,GB/T,Search NonEquilibrium,Equilibrium,Flash/NoFlash NonEquilibrium,Equilibrium,Flash/NoFlash Flash/NoFlash,NonEquilibrium,Search
TemperatureRange: Ambientto400°C Ambientto93°C,(5to93°Cwithcooling) Ambientto93°C,(5to93°Cwithcooling) Ambientto300°C(-20to300°Cwithcooling)
IgnitionMethod: ElectricorGas ElectricorGas ElectricorGas ElectricorGas
FlashDetection: Thermocouple Thermocouple Thermocouple Thermocouple
BathType: SolidBlock/Air Liquid/Liquid Liquid SolidBlock
PowerRequirement: 115Vor230Vac(switchable) 115Vor230Vac(switchable) 115Vor230Vac(switchable) 115Vor230Vac(switchable)
Size(HxWxD): 34x47x42cm 44x47x42cm 34x47x42cm 34x47x42cm
Weight(inc.Baseunit): 12kg 12kg 12kg 12kg
33T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk
PRODUCT PROFILE
81000-2 SETAVAP 2 RAPID AUTOMATIC VAPOUR PRESSURE TESTER ASTM D5191; IP 409; IP 481; IP 394, EN 13016; Correlates with ASTM D323; D5842; D6378; IP 69; IP 402 (Obs)
• Multi-Mode-Ptot,DVPE,EPA,Crude,Pabs• FixedLiquid/Vapourratio• “Mini”methodusesonly3mlsamplesize• AutomaticDrainandPurge
Aquickandsimpletouseinstrumentfordeterminingthevapourpressureofgasoline,solvents,lightcrudeoils,andsimilarproductsusingthe“Mini”testmethod.
SetaVap2ishighlyautomatedwithstepbystepinstructionsandpromptsbeingdisplayedonthecontrolpanel.Oncethetestprocedurehasbeenstartedoperatorinterventionisonlyrequiredtoinjectthesampleintothechamber,eventhepurgingandcleaningcycleiscarriedoutautomatically.
12200-3 SETA EXISTENT GUM SOLID BATH ASTM D381-IP 131; IP 540; BS 2000 Part 131; BS 4348 (obs); ISO 6246; DIN 51 784; NF M07-004; FTM 791 3302; JIS K2261
• 5Teststations• Integralsteamsuperheater• Digitaltemperaturecontrol• 140to260°Ctemperaturerange• Flowgaugecalibratedforairandsteam
A SolidBlockBathdesignedtocarryoutuptofivesimultaneoustestsfordeterminingexistentgumcontentinfuelsbytheJetEvaporationmethod.
TestPressureRange: 0to200kPa±0.5kPa(0.1kParesolution)UnitsofMeasurement: kPaorpsi(userselectable)ChamberTemperature: 37.8°C(100°F)±0.1°CModes: Ptot,DVPE,EPA,Crude,PabsPowerRequirement: 115Vacor220Vac(switchable),50/60Hz,70WSize(HxWxD)/Weight: 37x13x20cm/3.5kg
Operatingtemperaturerange: 140to260°C±5°CHeaters: 2x1kWOver-temperaturecut-out: 280°C(adjustable)Air/Steaminlet: 15mmo.dpipeSize(HxWxD): 45x35x50cmWeight: 45kg
81000-2➔
11860-3 SETASTILL DISTILLATION UNIT ASTM D86; D216 (obs); D447 (obs); D850; D1078; E133; IP 123; IP 191; IP 195
• Ambientto400°Cdistillationrange• Adjustableheightheater/flaskplatform• Toughenedglasswindow• Coolingfan
Thedistillationunit,mountedtotheleft,comprisesaflasksupportmechanism,heaterelements,andtheheatercontroller.Theflaskissupportedbyadrop-inceramic-glasssupportboardmountedtoaplatformthatisadjustableforheight.Thequartzenclosedheatingelementsareattachedtotheplatform,andarepoweredbyasolid-stateenergyregulatorandcalibratedcontrol.Acoolingfanisinstalledintherearofthedistillationunittoreducecoolingtimebetweendistillations.Atoughenedglassobservationwindowisfittedinthefrontofthedistillationunit,andaspillagecollectiontraywithoutletismountedbeneaththeheaters.
DistillationRange: Ambientto400°CVoltageRange: 110/120Vor220/240V,50/60Hz(switchable)Power: 1000WmaximumCondenserVolume: 7.2litre
Size(HxWxD)/Weight: CondenserUnit:47x37x25cm,DistillationUnit:47x21x21cm/12kgtotal
11860-3➔
12200-3➔
PRODUCT PROFILE
4 T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk
MaximumRCF: 72.5kgMaximumRPM: 3000TemperatureRange: 30to80°C±2°CTimerRange: 1to60minutesin1minutesteps,ContinuousOperationRotorCapacity: 4SamplesPowerRequirement: 230Vac(110Vtransformeroption)50/60Hz/1kWSize(HxWxD)/Weight: 40.1x56.41x63.93cm/86kg
Temperaturerange: Ambient+5°Cto150°CTemperaturestability: ±0.1°CBathfluid: WaterorOilsBathcapacity: 35LitresWaterInletNozzle: 10mm
Overflowdrain: 10mm
90000-3 SETA OIL TEST CENTRIFUGE FOR SEDIMENT & WATER IN CRUDE OILASTM D91; D96 (Obs); D893; D1290; D1796; D1966; D2273; D2709; D4007; IP 75 (Obs); IP 539 (Obs)
• Specificallydesignedfortestingoils• Heatedchamber,ambientto80°C• Static,nearverticalbucketpositioning• 4placeswingoutrotor• Membrane‘touch’controlpanel• Pre-heatfacilitytoensurebowlisattesttemperaturepriortotest• ConformstoIEC1010-1&1010-2-Dsafetyrequirements
Withatemperaturerangeof30to80°Candarotationalspeedofupto3000rpm,thisheatedchambercentrifugeisspecificallydesignedfortestingoils.Thelargediameterchamber,fourplacerotorandcushionedadaptorsallowtheuseofthecorrect6and8inchconical,pear-shapedandtracesedimenttubesasspecifiedbythevarioustestmethods.Theswingoutrotorensuresthatthesamplesareheldnearverticalwhenatrestallowingmoreprecisemeasurementofsediment.
11400-6 SILVER AND COPPER CORROSION BATHASTM D130-IP 154, ASTM D4048, ASTM D4814, BS 2000 Parts 112 & 154, DIN 51 811, EN 2160, FTM 791 5325, IP 112, IP 227 (obs), IP PM-DJ 2005, JIS K2513, NF M07-015
• Ambient+5°Cto150°Ctemperaturerange• 9teststations• Copper/Silvercorrosiontests
TheSilverandCopperCorrosionBathisastainlesssteelwateroroilbathdigitallytemperaturecontrolledto±0.1°Coveratemperaturerangeofambient+5°Cto150°C.
90000-3
99700-4 SALT CONTENT IN CRUDE ANALYSERASTM D3230; IP 265
• ASTMandIPmethods• Automaticsaltconcentrationcalculation• Pre-calibratedforimmediateuse• 2userdefinedcalibrationmodes• RS232interface• Batteryormainsvoltageoperation• Weatherproof
Aportableinstrumentfordeterminingtheapproximatechloride(salts)contentofcrudeoils.Theinstrumentisprecalibratedandautomaticallycalculatesthesaltconcentrationing/m3orpoundsperthousandbarrels(ptb)(lb/1000bbl).MeasurementscanbedisplayedordownloadedtoaPC.Suppliedwithcarrycase,mainsadaptor,software,RS232cable&instructionmanual.
Conductivityrange: 0.0to151lb/1000bbl(Res:0.1lb/1000bbl)0.0to430.0g/m3(Res:0.1g/m3)
Temperaturerange: -20to150°C(Res:0.1°C)Powersupply: 9voltdcbatteryormainsadaptor
110/120/220/240,50/60HzadaptorsuppliedSize(HxWxD): 20x7x3.5cmWeight(includingcarrycase): 1.6kg
99700-4
11400-6
55T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk
PRODUCT PROFILE
MeasuringPrinciple: ConstantVolumeCombustionChamberInjectionSystem: PintleType,singleholenozzle,airactuatedComputer: PentiumbasedPCwithinterfaceandscreen(supplied)CompressedGasRequirement: Air(20.9%O2)forcombustion,Air(IndustrialGrade)for
actuation,Nitrogen(IndustrialGrade)forfueldeliveryPowerRequirement: 120/220Vac@60Hzor220Vac@50HzSize(HxWxD)/Weight: 151x98x57cm/125kg
92000-3 IGNITION QUALITY TESTER (lQT™) - DERIVED CETANE NUMBER ANALYSIS EN 15195: 2005(E); ASTM D6890; IP 498; Correlates with ASTM D613
• AllDieselFuelsandBiodiesel• AutomatedTestProcedure• Small(<100ml)Sample• 20MinuteTest• Preciseresults-repeatabilityof0.91,reproducibility2.66@51CN• ApprovedspecificationtestforEN590,ASTMD975,D7467,BS2869
TheIgnitionQualityTester(IQT)isareliable,affordableandapprovedalternativetoacetaneengine.Itisafullyautomatedtestinstrumentforderivingthecetanenumberforawiderangeofmiddledistillatefuelsincludingconventionalandoilsands-baseddiesels,biodiesels,refinerystreams,plusfuelsusingoxygenateandnitratebasedcetaneenhancers.
92000-3➔
FilterBlockingTendency(FBT)Range: 1.0to30(lownumberbest)FilterabilityQualityFactor(FQF): 100to1(highnumberbest)MaximumPressure: 200kPaPowerRequirement: 110/120Vacor220/240Vac(switchable)Size(HxWxD)/Weight: 27x43x26cm/10kg
91600-3 SETA MULTI FILTRATION TESTER - PORTABLE TEST FOR FILTERABILITY/BLOCKING TENDENCY ASTM D2068; IP 387 (Procedures A, B & C); Correlates with ASTM D6426 NEW IP PM EA/08 Cold Soak Test Method for EN 590 Biofuel and FAME material.
• Compactandeasytouse• Resultinlessthan15mins• InterfaceforPCorPrinter
TheMFTisauniqueinstrumentdesignedtotesttheFilterBlockingTendency(FBT)andFilterabilityQualityFactor(FQF)ofdiesel,biodiesel(B100&B5/7/20),gasoil,gasturbinefuelandkerosine.
TestparametersforIP387/D2068andD6426testarepre-programmed.
91600-3➔
Setapartno: 94100-3 93531-7TemperatureRange: Ambientto-34°C Ambientto-51°CNumberandVolumeofCompartments: 3compartments,2litreseach 4compartments,2litreseachTotalNoofTestWells: 12 16CooldownTime: 1hourapprox.(32to-34°C) Approx2hrs(from32°Cto-51°C)PowerRequirement: 110/120Vacor220/240Vac,50/60Hz,750W 110/120V,60Hz220/240V,50Hz/1.8kWSize(HxWxD)/Weight: 60x60x85cm/115kg 95x63x63cm/115kg
94100-3 SETA COMPACT CLOUD AND POUR POINT CRYOSTAT FOR COLD FLOW TESTS ASTM D2500-IP 219, ASTM D5853-IP 441, ASTM D6422, ASTM D97-IP15, BS 2000 Parts 15 & 219, DIN 51 597 (obs), EN 23015, FTM 791 201, ISO 3015, ISO 3016, JIS K2269, NF T60-105
• 3IndividuallyTemperatureControlledCompartments• 4AirWellsineachCompartment• LargeTwoLitreCapacityCompartmentsforTemperatureStability• SingleStageCFCFreeRefrigeration
Thecryostatisequippedwiththreeindividuallytemperaturecontrolledcompartments.Eachtwolitrecompartmentcanaccommodatefourairwells.The94100-3issuppliedwithacompartmentthermometerand12testjars,eachcomprisinggraduatedglassware,thermometercork,andinsulatinggasketanddisk.Alowertemperature(-51°C)fourcompartmentCloud&PourPointCryostatisalsoavailable,Setapartnumber93531-7.
5 www.stanhope-seta.co.uk
94100-3➔
PRODUCT PROFILE
6 T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk
16670-0 SETA OXIDATION SOLID BLOCK BATH - 4 WAY ASTM D525; IP 40
• 4position• Dryblock• Overtemperaturecutout• Smallfootprint• Stability±0.1°C
TheSetaOxiSolidBlockBathisanaluminiumblockbathwithdigitaltemperaturecontrolthathasbeendesignedtoacceptuptofouroxidationvesselsforcarryingouttestsequivalenttotheIP40/D525testmethod.
TemperatureRange: Ambientto120°CStability: ±0.1°CBathCapacity: 35litresVoltage: 110/120V,50/60Hzor220/240V,50/60HzSize(HxWxD): Bath:44x35x26cm,OxfloControlUnit:64x36x33cmWeight: Bath:15kg,OxfloControlUnit:11kg
TemperatureRange: Ambient+5°to100°CBathType: DryBlockMaxNo.ofTestVessels: 4Heat-UpTimeto100°C: 80mins
16960-0 SETA 6 WAY OXIDATION BATH WITH WINDOW + OXFLO ASTM D943; D2274; D4310; D7462; IP 157; IP 388
• 6positionoilbath• Reliabledigitalthermostirunit• SetaOxfloControllerandflowmetersincluded• Lowliquidprotection• Overtemperaturecutout• Lighttightviewingwindow
Oilbathandoxygenflowcontrolunitusedforquantativeanalysisofthetendencyofoilsandfuelstoformsludge,acidsanddepositswhenexposedtooxygeninthepresenceofmetalliccatalystsoverextendedperiods.
TheseparateOxflocontrolunit(notshown)includesagasinletpressureregulator,pressuregaugeandsixprecisionflowmeterscalibratedforoxygenat3litres/hour,21°Cand0.4barpressure.Safetyfeaturesincludelowlevelliquidprotectionandovertemperaturecut-outs.
16960-0➔
16670-0➔
TemperatureRange: Ambientto150°C
TemperatureStability: ±0.01°upto100°C±0.02°between100and150°C
TemperatureUniformity: ±0.02°at40and100°C
TubeCapacity: upto6
BathFluid: OilorWater
BathCapacity: 50Litres
Size(HxWxD): 56x35x44cm
Weight: 33kg
84200-0 KV6 VISCOMETER BATH ASTM D2170-IP 319, ASTM D445-IP 71, ASTM D446, BS 188, BS 2000 Parts 71 & 319, DIN 51 366, DIN 51 562, EN 12595, EN 3104, FTM 791 305, ISO 3105, JIS K2283, NF T60-100, NF T60-136
• Upto6viscometertubes• 50litreoil/waterbath• Temperaturestability±0.01upto100°Cand±0.02between100and150°C• Temperaturerangeambientto150°C• Digitaldisplaywith0.01°Cresolution• Toughenedglassfrontpanel• Integralbacklighting
TheSetaKV-6hasa50litretemperaturecontrolledbaththatcanaccommodateuptosixstandardviscometertubes.Digitaltemperaturecontrolandaninbuiltcoldwatercoolingcoilprovideaccurateandstabletesttemperaturesfromambientto150°C(±0.01°Cupto100°Cand±0.02°Cbetween100and150°C).Thebathisprotectedbylowliquidlevelandovertemperaturecut-outs.
Equippedwithatoughenedglassfrontwindow,easilyaccessibledrainvalve,integralbacklighting,topplate,provisionforreferencethermometerandattachments.
84000-0
77T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk
PRODUCT PROFILE
SETA REFERENCE & VERIFICATION MATERIALS – SINGLE & MULTI TEST VERIFICATION MATERIALSProducts: Diesel, Biodiesel, Gasoline, Jet & Lubricating Oil
• VerificationtoASTM/CEN/ISO/IP• TraceabletoISO9001:2000• 18MonthValidity
AllSetainstrumentsaremanufacturedtothehighestpossiblestandardstoprovideaccurate,reliableandrepeatableresultsdemandedbymodernlaboratories.TomaintaintheconfidenceofthosewhousetheresultsitisessentialtocarryoutregularverificationofthoseresultsandalsotomaintainthecalibrationofSetainstruments.
TherangeofSetaVerificationMaterialsforfuelstestingincludes;
• SimulatedDistillation(SIMDIS)• WaterdeterminationbyKarlFischer• LubricityofUltraLowSulphurDiesel(ULSD)byHFRR• VapourPressurebyevacuatedchambertest• RefereevaluesforLowSulphurGasolinemeetingASTMandIPtestmethodprotocols
TherangeofSetaVerificationmaterialsincludes‘MultiTest’samples,whichareauniquesecondaryreferencematerialthatprovidetraceablevalidationofseveraldifferenttestparametersfromonesourceofsample.
99708-0➔
isinstruments.
Conductivityrange: 0-2000pS/m±2pS/m(±2%ofreading)Resolution: 0.1pS/mTemperatureRange: 0-35°C*(±0.1°C)Size(HxWxD): 31x11x10cmWeight: 0.5kg
86400-2 PORTABLE FUEL INTEGRITY TEST KIT - RAPID CHECK FOR CONTAMINATION IN AVIATION FUEL
• SuitableforJetfuelandotherlightdistillatefuels• Multipletestsinsinglekit• Compact,easytocarryrucksack• IdealforshipboarduseforCargoInspectionandassurance
Aselfcontainedkitoftestequipmentforrapiddetectionofcontaminationinfuels.Thekithasbeendesignedtofitintoasmallpurposemaderucksackenablingittobeeasilytransportedtotestsiteswhichhaveonlylimitedordifficultaccess.Itisideallysuitedforshipboarduseprovidingbothrapidandeasyverificationofproductintegritypriortooff-loading.
Thekitcomprisesof5keyteststhatallowgo/nogotestingoffuels;
•Flashpoint(ASTMD3828)–usingtheSeries3ClosedCupTester,completewithsyringesandportablegassupply•Density–AnATEXapproveddigitaldensitymeter,IP559•Conductivity(ASTMD2624)–UsingadigitalconductivitymeterWaterContent-ShellWaterCapsulesofferdetectionto30ppm(80tests&syringes)•Digicell–DigitalreadoutofWatercontent,100-3000ppm,200-10000pmand0-10%(50tests)
99708-0 HAND HELD CONDUCTIVITY METERASTM D2624; IP 274
• HigherAccuracyACMeasurement(±2%ofreading)• Conductivityandtemperatureoutputcapability• Storesupto10DataLocations• USBinterfaceforeaseofdatatransfertouser• FullyTemperatureCompensatedMeasurement
TheSetaHandheldConductivityMeterprovidesanaccurateandrapidconductivitymeasurementofdistillatefuels;andisspecificallydesignedfortestinglowconductivityfluidssuchasaviationkerosene,ULSD,homeheatingfuel,Naphtha,andprintingink.
86400-2
99708-0➔➔
PRODUCT PROFILE
8 T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk
Seta Analytics provide analytical solutions for Hydrocarbon Petroleum products. It is a division of Stanhope-Seta which combines long established experience of testing petroleum products with the latest measurement technologies to provide enhanced analytical solutions for exploration, refining, petrochemical, distribution and marketing operations.
Current developments include laser based measurement for particle counting, electrochemical sensors for H2S detection and miniature FTIR technology for low level detection of FAME in Jet Fuels.
London StreetChertseySurrey KT16 8APEngland
T + 44 (0) 1932 564391F + 44 (0) 1932 568363E [email protected] www.stanhope-seta.co.uk
Analytical solutions for hydrocarbon petroleum products
H2S AnalyserASTM D7621, IP 570, ISO 8217 Marine Fuel Specification
FIJI - Fame in Jet InstrumentRapid Screening to IP 583