product presentation 2007

27
Product Presentation 2007 SUPER INVERTER

Upload: abie

Post on 02-Feb-2016

42 views

Category:

Documents


0 download

DESCRIPTION

Product Presentation 2007. SUPER INVERTER. SKY AIR & PACKAGED. SUPER INVERTER. Overview. 1.Model range 2.Product features - Easy Installation - Flexible Design - Energy Saving 3. Specifications. 1. Model range. MARKET. Inverter High ‘RZQ-series’ Heat pump. RZQ71CV1 - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Product Presentation 2007

Product Presentation 2007

SUPER INVERTER

Page 2: Product Presentation 2007

2Apr 22, 2023

Public

SKY AIR & PACKAGEDSUPER INVERTER

Page 3: Product Presentation 2007

3Apr 22, 2023

Public

1. Model range

2. Product features- Easy Installation

- Flexible Design

- Energy Saving

3. Specifications

Overview

Page 4: Product Presentation 2007

4Apr 22, 2023

Public

MARKET

Hig

h e

nd

Mai

nst

ream

Lo

w

end

Inverter High

‘RZQ-series’

Heat pump

No

nIn

verterInverter

Non-Inverter H/P ‘REQ-series’

Non-Inverter H/P ‘RQ-series’

Non-Inverter C/O ‘RR-series’

Inverter Low ‘RZQS-series’

RZQ200BW (3ph) RZQ250BW (3ph)

RZQ71CV1 RZQ100CV1 (1ph)RZQ125CV1RZQ140CV1

RZQ100BW1 RZQ125BW1 (3ph)RZQ140BW1

1. Model range

Sky Air

Packaged

Page 5: Product Presentation 2007

5Apr 22, 2023

Public

Wide range of indoors:8 different models in 33 different variants

1. Model Range

Page 6: Product Presentation 2007

6Apr 22, 2023

Public

MODEL NAME

Ceiling suspended 2 x 2 cassette 4-way ceiling Wall mounted High ESP duct

FHQ FFQ FUQ FAQ FDQ

35 50 60 71 100 125 35 50 60 71 100 125 71 100 125

RZQ71CV1 2 P 2 P P

RZQ100CV1 3 2 P 3 2 P P

RZQ125CV1 4 3 2 P 4 3 2 P P

RZQ140CV1 4 3 2 4 3 2 2

MODEL NAME

Round flow High COP Round flow cassette Duct (medium ESP)

FCQH FCQ FBQ

71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 140

RZQ71CV1 P 2 P 2 P

RZQ100CV1 P 3 2 P 3 2 P

RZQ125CV1 P 4 3 2 P 4 3 2 P

RZQ140CV1 2 P 4 3 2 P 4 3 2 P

Combination Table RZQ71/100/125/140C

1. Model Range

Page 7: Product Presentation 2007

7Apr 22, 2023

Public

Wide range of indoors:8 different models in 30 different variants

1. Model Range

Page 8: Product Presentation 2007

8Apr 22, 2023

Public

MODEL NAME

4-way-blow cassette Round flow cassette Duct (medium ESP)

FCQ-B FCQ-C FBQ

35 50 60 71 100 125 35 50 60 71 100 125 35 50 60 71 100 125

RZQ200C 4 3 3 2 4 3 3 2 4 3 3 2

RZQ250C 4 2 4 2 4 2

MODEL NAME

Ceiling suspended 2 x 2 cassette 4-way ceiling Wall mounted High ESP duct

FHQ FFQ FUQ FAQ FDQ

35 50 60 71 100 125 35 50 60 71 100 125 71 100 125 200 250

RZQ200C 4 3 3 2 4 3 3 2 3 2 P

RZQ250C 4 2 4 2 2 P

200 class 250 class

P: Pair combination 200 250

2: Twin 100 + 100 125 + 125

3: Triple 60 + 60 + 60 / 71 + 71 + 71 -

4: Double twin 50 + 50 + 50 + 50 60 + 60 + 60 + 60

Combination Table RZQ200/250C

1. Model Range

Page 9: Product Presentation 2007

9Apr 22, 2023

Public

Easy Installation

• Easy piping:=> max. piping length 75m=> piping length below 5m=> re-use of field piping=> flexible piping diameter

• Compact design: => same casing 4/5/6 HP• Anti-corrosion treatment• Light weight: => 98kg for 4/5/6 HP

Flexible Design

• Flexible operation range:=> C/O operation possible=> down to -20°C in heating=> up to +50°C in cooling

• EDP room application:=> R/C field setting=> I/U operation limit 11°C

• Wide range of indoors:=> 8 different models=> 33 different variants

• D-Bacs compatibility

Energy Saving• Increased efficiency:

=> top COP=> DC inverter technology=> I-demand

• Predicted mean value

Environmentally friendly

• Reduction of initial charge refrigerant• Corresponding to F-gas regulation• RoHS-complaint

2. Product Features

Page 10: Product Presentation 2007

10Apr 22, 2023

Public

Easy InstallationPiping length:

• Maximum piping length = 75m

• Minimum piping length = 5m

minimum allowed piping length is 3m (by field setting)

• Flexible piping diameter

suitability of Sky Air models to existing pipes (of other brands)

H = 30m

ModelLiquid Piping Gas Piping

Size Down Standard Size Up Size Down Standard Size Up

RZQ71CV1 Ø 6.4 Ø 9.5 Ø 12.7 Ø 12.7 Ø 15.9 --

RZQ100CV1 Ø 6.4 Ø 9.5 Ø 12.7 -- Ø 15.9 Ø 19.1

RZQ125CV1 Ø 6.4 Ø 9.5 Ø 12.7 -- Ø 15.9 Ø 19.1

RZQ140CV1 Ø 6.4 Ø 9.5 Ø 12.7 -- Ø 15.9 Ø 19.1

• Re-use of field piping

2. Product Features

Page 11: Product Presentation 2007

11Apr 22, 2023

Public

Compact design:

• Dimensions

same casing for 100, 125 & 140 class models

reduced height for 100 & 125 class (-175mm)

=> 1.170mm * 900mm * 320mm (H*W*D)

Height Width Depth

RZQ100B8V3 1.345 900 320

RZQ100CV1 1.170 900 320

RZQ125B8V3 1.345 900 320

RZQ125CV1 1.170 900 320

RZQ140CV1 1.170 900 320

Light weight:

• Same weight for 100, 125 & 140 class models

• Reduced weight for 100 & 125 class

=> 98kgNew RZQ 100/125/140

RZQ 100/125

98kg106k

g

2. Product Features

Easy Installation

Page 12: Product Presentation 2007

12Apr 22, 2023

Public

Easy Installation

• Easy piping:=> max. piping length 75m=> piping length below 5m=> re-use of field piping=> flexible piping diameter

• Compact design: => same casing 4/5/6 HP• Anti-corrosion treatment• Light weight: => 98kg for 4/5/6 HP

Flexible Design

• Flexible operation range:=> C/O operation possible=> down to -20°C in heating=> up to +50°C in cooling

• EDP room application:=> R/C field setting=> I/U operation limit 11°C

• Wide range of indoors:=> 8 different models=> 33 different variants

• D-Bacs compatibility

Energy Saving• Increased efficiency:

=> top COP=> DC inverter technology=> I-demand

• Predicted mean value

Environmentally friendly

• Reduction of initial charge refrigerant• Corresponding to F-gas regulation• RoHS-complaint

2. Product Features

Page 13: Product Presentation 2007

13Apr 22, 2023

Public

Flexible DesignWide operation range:

• In cooling: -15°C / 50°C (vs. -5°C / 46°C for RZQS-series)

• In heating: -20°C / 15.5°C (vs. -15°C / 15.5°C for RZQS-series)

• C/O operation possible (setting to disable heating mode)

Indoor 12 to 28 ℃WB (EDP : 11 ℃WB) Indoor 10 to 27 ℃WB

Outdoor -15 to 50 ℃DB Outdoor -20 to 15.5 ℃DB

Cooling

-20

-10

0

10

20

30

40

50

60

5 10 15 20 25 30

Indoor temp (WB)

Out

door

tem

p (D

B)

Op

era

tio

n

Pu

ll-d

ow

n

Heating

-25

-20

-15

-10

-5

0

5

10

15

20

5 10 15 20 25 30

Indoor temp (DB)

Out

door

tem

p (W

B)

Op

era

tio

n

Wa

rm-u

p

2. Product Features

Page 14: Product Presentation 2007

14Apr 22, 2023

Public

EDP room application:

MODEL NAME

Round flow High COP Round flow cassette Duct (medium ESP)

FCQH FCQ FBQ

71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125

RZQ71CV1 P 3 2 P 3 2 P

RZQ100CV1 2 P 4 3 2 P 4 3 2

RZQ125CV1 2 P 4 3 2 P 4 3 2

RZQ140CV1

MODEL NAME

Ceiling suspended 2 x 2 cassette 4-way ceiling Wall mounted High ESP duct

FHQ FFQ FUQ FAQ FDQ

35 50 60 71 100 125 35 50 60 71 100 125 71 100 125

RZQ71CV1 3 2 P 3 2 P P

RZQ100CV1 4 3 2 4 3 2 2

RZQ125CV1 4 3 2 4 3 2 2

RZQ140CV1

2. Product Features

Flexible Design

Page 15: Product Presentation 2007

15Apr 22, 2023

Public

EDP room application:

• EDP application is incorporated by field setting with R/C

• Extended operation range till 11°CWB (indoor) in cooling mode

• Minimum allowed piping length should be 3m

D-Bacs compatibility:

• Compatibility with Intelligent Manager

• Compatibility with Intelligent Touch Controller

Indoor Outdoor

4 HP 3 HP

6 HP 4 HP

6 HP 5 HP

Basic logic for EDP room

2. Product Features

Flexible Design

Page 16: Product Presentation 2007

16Apr 22, 2023

Public

Easy Installation

• Easy piping:=> max. piping length 75m=> piping length below 5m=> re-use of field piping=> flexible piping diameter

• Compact design: => same casing 4/5/6 HP• Anti-corrosion treatment• Light weight: => 98kg for 4/5/6 HP

Flexible Design

• Flexible operation range:=> C/O operation possible=> down to -20°C in heating=> up to +50°C in cooling

• EDP room application:=> R/C field setting=> I/U operation limit 11°C

• Wide range of indoors:=> 8 different models=> 33 different variants

• D-Bacs compatibility

Energy Saving• Increased efficiency:

=> reduced start-up time=> DC inverter technology=> I-demand

• Predicted mean value

Environmentally friendly

• Reduction of initial charge refrigerant• Corresponding to F-gas regulation• RoHS-complaint

2. Product Features

Page 17: Product Presentation 2007

17Apr 22, 2023

Public

Energy Saving

• Less frequent start/stop cycles

• Automatic throttle back of capacity

• Start-up time down by 1/3

• Operating at partial load possible

• Varying speed of compressor

Inverter technology:

=> Energy efficiency significantly higher

Sine Wave DC inverter:

• Increase of efficiency

• High harmonics reduced

=> 98% electricity used

2. Product Features

Page 18: Product Presentation 2007

18Apr 22, 2023

Public

Swing CompressorSwing Compressor

Swing bush

Ref. Gas

The piston which the blade and the roller unified

Discharge

Suction

Scroll

Reluctance DC Motor

Low Pressure Part

High Pressure Part

• Low starting current

• More stable set points

• Class 71 • Friction & leaks suppressed• Improved energy saving

Scroll CompressorScroll Compressor

Reluctance DC compressor:

• Class 100, 125 & 140• Easier superheat control• Improved performance

2. Product Features

Energy Saving

Page 19: Product Presentation 2007

19Apr 22, 2023

Public

4 Neodymium magnets:

• More powerful than ferrite types

• Better performance

• Higher energy efficiency

Energy cost

savings ↑

DC Fan motor:

• Improvements in operating efficiency (especially during low speed)

• Improvement in energy efficiency (at low velocities in particular)

Neodymium magnets Increased torque for same consumption

Optimized version of DC motor Additional torque / same energy consumption

FEATURES BENEFITS

2. Product Features

Energy Saving

Page 20: Product Presentation 2007

20Apr 22, 2023

Public

I-demand function:

• Operation: difference actual/predefined power consumption minimized

• Max. power consumption limited to 80%~40% of rated power input

• KRP58M51 (optional adaptor) required

Po

wer

Co

nsu

mp

tio

n

(kW

)

Time

Maximum power consumption can be easily controlled: The maximum capacity is maintained while the power consumption is kept at a certain level. The set value can be freely changed.

When the function is turn on, Demand 1 starts as default setting(Setting on the optional PCB)

External InputDemand 1 ~ 3

ExternalControl Adaptor(Optional PCB)

<Auto>

Setting Power Consumption

Demand 1 Select from 80%-70%-60 %

Demand 2 40 %

Demand 3 0 %Contact Changeover

<Manual>

Setting way

2. Product Features

Energy Saving

Page 21: Product Presentation 2007

21Apr 22, 2023

Public

Predicted Mean Value:

[Day]Muggy

[Night]Chilly

[Morning]Chilly

Always comfortable

Cost-efficient operation

Cooling

Shortage of capability Over capabilityOver capability

Unnecessary cooling

Unnecessary cooling

High

Room Temperature

Low

Set point 23°C

Energy saving Energy saving Energy saving Energy saving

Auto Operation Mode:

Controls room temperature in accordance with feeling temperature.

Normal Operation Mode:

Controls room temperature at a designated temperature.

[Day]Muggy

[Night]Chilly

[Morning]Chilly

Always comfortable

Cost-efficient operation

2. Product Features

Energy Saving

Page 22: Product Presentation 2007

22Apr 22, 2023

Public

Predicted Mean Value:

Heating

[Morning]Cold

[Night]Cold

[Day]Hot

Always comfortable

Cost-efficient operation

High

Room Temperature

Over capability

Unnecessaryheating

Low

Shortage of capability

Shortage of capabilitySet point 21°C

Energy saving Energy saving

2. Product Features

Energy Saving

Auto Operation Mode:

Controls room temperature in accordance with feeling temperature.

Normal Operation Mode:

Controls room temperature at a designated temperature.

Page 23: Product Presentation 2007

23Apr 22, 2023

Public

RZQ200/250C

• Energy saving=> high efficiency => power limit setting

• Easy piping:=> max. piping length 100m=> re-use of field piping=> flexible piping diameter

• Light weight: => 198kg for 8 & 10 HP

• Possibility of C/O operation • Night quiet operation

Remarks• No change in option list• Not suited:

=> for EDP room applications=> for piping length < 5m

2. Product Features

Page 24: Product Presentation 2007

24Apr 22, 2023

Public

  

Super Inverter

Model name RZQ71CV1 RZQ100CV1 RZQ125CV1 RZQ140CV1

4-way Casette Type Hi Casette / Thin Casette

Rated cooling capacity 7.1kW 10.0kW 12.5kW 14.0kW

Rated cooling COP (Hi/Thin Cassette) 3.59 / 3.36(A) / (A)

3.76 / 3.61(A) / (A)

3.38 / 3.22(A) / (A)

3.02 / 2.61(B) / (D)

Max cooling capacity 8.0kW 11.2kW 14.0kW 15.4kW

Rated heating capacity 8.0kW 11.2kW 14.0kW 16.0kW

Rated heating COP (Hi/Thin Cassette)4.06 / 3.62

(A) / (A)4.39 / 3.71

(A) / (A)3.92 / 3.54

(A) / (B)3.61 / 3.21

(A) / (C)

Max heating capacity 9.0kW 12.8kW 16.2kW 18.0kW

Operation sounds(Cool/Heat) 47/49 dB(A) 49/51dB(A) 50/52 dB(A)

Sound Power Cooling 63 dB(A) 65 dB(A) 66 dB(A) 67 dB(A)

DimensionsH770×W900

×D320mmH1170×W900×D320mm

Weight 68kg 98kg

Refrigerant Quantity 2.8kg 3.7kg

Communication QA Communication

Ref.pipe sizeGas φ15.9

Liquid φ9.5

Ref.pipe length

MAX ref.pip length 50m 75m

MIN ref.pip length 5m

Charged for 30m

3. Specifications

Page 25: Product Presentation 2007

25Apr 22, 2023

Public

          

RZQ200C RZQ250C

FDQ200BV3 FDQ250BV3

Cooling

Rated Capacity kW 20 24,1

EER   3.21 (A) 2,81 (C)

Min. - Max. Capacity kW 7,5 - 22,4 9,1 - 26,5

Heating

Rated Capacity kW 23 26,4

COP   3.41 (B) 3,21 (C)

Min. - Max. Capacity kW 8,5 - 25 9,1 - 29,0

Dimensions

Height mm 1680 1680

Width mm 930 930

Depth mm 765 765

Weight   kg 198 198

Piping Connection

PipingLength

Minimum m 5 5

Maximum m 100 100

Chargeless m 30 30

DiameterLiquid mm 9,5 12,7

Gas mm 22,2 22,2

Height Difference   m 30 30

Operation RangeCooling ℃DB -5 / + 46 -5 / + 46

Heating ℃WB -15 / +15 -15 / +15

Sound LevelSound Pressure CO/HP dBA 57/57 57/58

Sound Power (Cooling) dBA 78 78

3. Specifications

Page 26: Product Presentation 2007

26Apr 22, 2023

Public

Page 27: Product Presentation 2007

27Apr 22, 2023