NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 1 of 34
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Johns Manville Corporation
717 17th Street, 9th Floor
Denver, CO 80202
SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County
Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade
County) reserve the right to have this product or material tested for quality assurance purposes. If
this product or material fails to perform in the accepted manner, the manufacturer will incur the
expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it
is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: JM PVC Single Ply Roof Systems over Lightweight Concrete Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 15-0203.02 and consists of pages 1 through 34.
The submitted documentation was reviewed by Hamley Pacheco, P.E.
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 2 of 34
ROOFING SYSTEM APPROVAL
Category:
Roofing
Sub-Category:
Single Ply
Materials:
PVC
Deck Type:
Lightweight Concrete
Maximum Design Pressure:
-502.5 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1
Product Name
Dimensions
Test
Specifications
Product Description
JM PVC
50 mil x roll width x 100’
60 mil x roll width x 100’
80 mil x roll width x 75’
ASTM D4434 PVC polyester reinforced
membrane with DuPont™ Elvaloy®
KEE. Available in 3.25’, 5’, 6.5’,
10’, and 12’ rolls.
JM PVC Fleece
Backed
50 mil x roll width x 90’
60 mil x roll width x 90’80
mil x roll width x 75’
ASTM D4434 PVC polyester reinforced
membrane backed with a
lightweight polyester fleece.
Available in 6.33’ and 12’ rolls.
DynaBase
39-3/8” x 49’2” ASTM D6163
A glass reinforced SBS modified
bitumen base sheet.
DynaBase HW
39-3/8” x 49’2” ASTM D6163
A glass reinforced SBS modified
bitumen base sheet for heat
welded applications.
DynaFast 180 S 39-3/8” x 49’2” ASTM D6164 A polyester reinforced SBS
modified bitumen base or inner
ply sheet.
JM Vapor Barrier
SA
44.9” x 133’ Proprietary Self-adhered, SBS modified
bituminous sheet with tri-laminate
woven polyethylene surface
JM PVC Profile 1-1/2” wide x 1-1/4” high x
10’ long
Proprietary Non-reinforced, extruded PVC for
simulating the aesthetics of
standing seam metal roofing.
JM PVC Spine ¾” wide x 13/16” high
x 7’ long
Proprietary Non-reinforced, extruded PVC for
simulating the aesthetics of
standing seam metal roofing.
Urethane Insulation
Adhesive
N/A Proprietary Urethane insulation adhesive.
JM Two Part
Urethane Insulation
Adhesive
N/A Proprietary A two-part urethane insulation
adhesive.
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 3 of 34
Product Name
Dimensions
Test
Specifications
Product Description
One-Step Foamable
Adhesive
N/A Proprietary Two part urethane low rise foam
insulation
JM PVC Membrane
Adhesive
(Low VOC)
N/A Proprietary Low solvent based adhesive.
JM PVC Membrane
Adhesive
(Water Based)
N/A Proprietary Water based adhesive.
JM Roofing System
Urethane Adhesive
N/A Proprietary A two-part urethane insulation
adhesive.
MBR Low VOC
Membrane Adhesive
N/A Proprietary Single component, polyurethane
low solvent based adhesive
MBR RA
Membrane Adhesive
N/A Proprietary Two-part, cold process membrane
adhesive
JM PVC Penetration
Pan
Various ASTM D4434 Molded PVC for flashing
penetration.
JM PVC Pipe Boots Various ASTM D4434 Non-reinforced molded PVC
flashing penetrations.
JM PVC Universal
Corner
Various ASTM D4434 Non-reinforced molded PVC for
inside and outside corner flashing.
JM PVC T-Joint
Patch
Various ASTM D4434 Non-reinforced PVC used to cover
T-joints and fasteners.
JM PVC Detail
Membrane
Various ASTM D4434 Non-reinforced PVC used for pipe
and corner flashing.
JM PVC Detail
Strip
Various ASTM D4434 PVC used to waterproof joints.
JM PVC Coated
Metal
Various ASTM D4434 JM PVC laminated onto
galvanized steel for metal
flashings and edge details.
JM PVC Walkpad
Various ASTM D4434 Textured PVC walk pad.
JM PVC Heavy-
Duty
Various ASTM D4434 Textured PVC walk pad.
JM PVC Split Pipe
Boot
Various ASTM D4434 Reinforced PVC used to flash vent
stacks and other round
penetrations
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 4 of 34
APPROVED INSULATIONS: TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
Invinsa Roof Board High-density polyisocyanurate with fiber
glass reinforced facers
Johns Manville
JM SECUROCK Gypsum‐Fiber
Roof Board
Fiber reinforced gypsum cover board Johns Manville
ENRGY 3, ENRGY 3 25 PSI,
ValuTherm, ValuTherm 25 PSI,
R-Panel, R-Panel 25 PSI
Polyisocyanurate Insulation Johns Manville
ENRGY 3 AGF, ENRGY 3 AGF
25 PSI, ValuTherm AGF,
ValuTherm AGF 25 PSI
Polyisocyanurate Insulation with glass
facer
Johns Manville
ENRGY 3 CGF, ENRGY 3 CGF
25 PSI, ValuTherm CGF,
ValuTherm CGF 25 PSI
Polyisocyanurate Insulation with coated
glass facer
Johns Manville
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 5 of 34
APPROVED FASTENERS: TABLE 3
Fastener
Number
Product
Name
Product
Description
Dimensions
Manufacturer (With Current NOA)
1. Trufast Twin Loc-
Nail Batten
Fastener
Base sheet fastener Various Altenloh, Brink &
Co. U.S., Inc.
2. Trufast Twin Loc
Coiled Batten Bar
Oval pre-punched metal
batten bar
1” x 100’ coil Altenloh, Brink &
Co. U.S., Inc.
3. Lightweight
Concrete (LWC)
CR Base Fastener
Galvanized double spreading
leg fastener for securing base
sheets to lightweight
insulating concrete.
1.2” or 1.7”
leg length;
2.7” dia. Plate
Johns Manville
4. Millennium
Hurricane Force 1-
Part Membrane
Adhesive
Single component,
polyurethane low solvent
based adhesive
N/A ADCO Products
d.b.a. Royal
Adhesives &
Sealants
5. Millennium
Hurricane Force
Membrane
Adhesive
Two-part, cold process
membrane adhesive
N/A ADCO Products
d.b.a. Royal
Adhesives &
Sealants
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 6 of 34
EVIDENCE SUBMITTED:
Test Agency Name Identifier Report Date
FM Approvals 3018807 FM 4470 06/25/04
3014692 FM 4470 08/05/03
3016629 FM 4470 12/12/03
3046174 FM 4470 04/03/13
3023458 FM 4450 07/18/06
3025881 FM 4450 08/09/06
3030351 FM 4470 08/01/07
3037540 FM 4450 10/20/10
3040105 FM 4470 11/24/10
3056049 FM 4470 01/13/16
Trinity|ERD J45020.09.13-1-R1 TAS 114 09/12/13
J45960.09.13 TAS 114 09/16/13
JM-SC11320.03.16 TAS 114 03/10/16
Momentum Technologies, Inc. NX21J0A ASTM D 4434 06/01/11
NX21J0B ASTM D 4434 07/20/11
NX21J0C ASTM D 4434 06/01/11
PRI Construction Materials JMC-086-02-01 Rev 1 TAS114 J 01/03/13
Technologies, LLC JMC-088-02-01.4 ASTM D1876/TAS 117(A)/(B)
TAS 114(C)
07/01/14
JMC-107-02-01.7 ASTM D5147/D903/D1876
TAS 117(A)/(B)/(C)
03/31/16
JMC-108-02-01 TAS 114(J) 04/16/13
JMC-131-02-01 TAS 114(J) 08/20/13
JMC-132-02-01 TAS114 04/17/13
JMC-132-02-02 TAS114 07/01/13
JMC-141-02-01 TAS 114(J) 04/18/13
JMC-143-02-01 TAS 114(D) 07/01/13
JMC-162-02-01 FM 4474/TAS114 09/06/13
JMC-163-02-01 FM 4474/TAS114 09/06/13
JMC-242-02-01 FM 4474/TAS114(J) 11/18/15
JMC-245-02-02 FM 4474/ TAS114(D) 03/29/16
JMC-246-02-01 FM 4474/TAS114(D) 03/29/16
JMC-267-02-02.2 FM 4474/ TAS114(D) 04/21/17
Atlantic & Caribbean ACRC 06-045 TAS 114 12/15/06
Roofing Consultants, LLC ACRC 14-026 TAS 114(D) 11/19/14
ACRC 14-027 TAS 114(D) 11/19/14
ACRC 14-028 TAS 114(D) 11/20/14
ACRC 14-029 TAS 114(D) 11/20/14
ACRC 14-031 TAS 114(D) 11/21/14
ACRC 14-032 TAS 114(D) 11/24/14
ACRC 14-034 TAS 114(D) 11/25/14
ACRC 14-035 TAS 114(D) 11/25/14
ACRC 14-036 TAS 114(D) 11/26/14
ACRC 14-038 TAS 114(D) 12/02/14
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 7 of 34
Test Agency Name Identifier Report Date
ACRC 14-041 TAS 114(D) 12/03/14
ACRC 14-042 TAS 114(D) 12/04/14
ACRC 14-043 TAS 114(D) 12/04/14
ACRC 14-044 TAS 114(D) 12/05/14
ACRC 14-046 TAS 114(D) 12/09/14
DECK STRESS ANALYSIS CALCULATIONS/REPORTS
Engineer/Agency Identifier Assemblies Date
Zachary R. Priest, P.E. Signed/Sealed
Calculations
E(2), F(6)
F(1)
04/25/16
08/29/16
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 8 of 34
Membrane Type: Single Ply, PVC
Deck Type 4I: Lightweight Concrete, Insulated
Deck Description: Minimum 300 psi Lightweight Insulating Concrete deck which records a
Minimum Characteristic Resistance Force (MCRF) of 131 lbf when tested with
1.7” Lightweight Concrete (LWC) CR Base Fastener in accordance with TAS
105.
Deck: Structural concrete deck.
System Type A(1): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ENRGY 3, ENRGY 3 25 PSI, ValuTherm, ValuTherm 25 PSI, R-Panel, R-Panel 25 PSI,
ENRGY 3 AGF, ENRGY 3 AGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI,
ENRGY 3 CGF, ENRGY 3 CGF 25 PSI, ValuTherm CGF, ValuTherm CGF 25 PSI
Minimum 1.5” thick N/A N/A
Note: All insulation shall be adhered to the deck with JM Two-Part Urethane Insulation Adhesive
or One Step Foamable Adhesive applied in ¾” – 1” wide ribbons spaced 12” o.c. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Membrane fully adhered to the insulation as specified below.
Option #1: JM PVC Membrane fully adhered to the insulation with JM PVC Membrane
Adhesive (Low VOC) applied at a rate of 0.83 gal/sq The minimum 2.5” wide
side laps that shall be sealed with a minimum 1.5” wide heat weld.
Option #2: JM PVC Fleece Backed membrane adhered to insulation with ½” – ¾” wide
beads of JM Roofing System Urethane Adhesive, spaced 4” o.c. with minimum
2.5” wide side laps that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -80 psf. (See General Limitation #9.)
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 9 of 34
Membrane Type: Single Ply, PVC
Deck Type 4I: Lightweight Concrete, Insulated
Deck Description: Minimum 300 psi Lightweight Insulating Concrete deck which records a
Minimum Characteristic Resistance Force (MCRF) of 131 lbf when tested with
1.7” Lightweight Concrete (LWC) CR Base Fastener in accordance with TAS
105.
Deck: Structural concrete deck.
System Type A(2: One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ENRGY 3, ENRGY 3 25 PSI, ValuTherm, ValuTherm 25 PSI, R-Panel, R-Panel 25 PSI,
ENRGY 3 AGF, ENRGY 3 AGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI,
ENRGY 3 CGF, ENRGY 3 CGF 25 PSI, ValuTherm CGF, ValuTherm CGF 25 PSI
Minimum 1.5” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
JM SECUROCK Gypsum‐Fiber Roof Board
Minimum ¼” thick N/A N/A
Note: All insulation shall be adhered to the deck with JM Two-Part Urethane Insulation Adhesive
or One Step Foamable Adhesive applied in ¾” – 1” wide ribbons spaced 12” o.c or JM Roofing
System Urethane Adhesive applied in ½ - ¾ ” ribbons spaced 12” o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: JM PVC Membrane fully adhered to the insulation as specified below.
Option #1: Membrane is fully adhered to the insulation with JM PVC Membrane Adhesive
(Water Based) applied at a rate of .67 gal/sq. on both membrane and the substrate.
The minimum 2.5” wide side laps that shall be sealed with a minimum 1.5” wide
heat weld.
Option #2: Membrane is fully adhered to the insulation with JM PVC Membrane Adhesive
(Low VOC) applied at a rate of 0.83 gal/sq, on both the membrane and the
substrate. The minimum 2.5” wide side laps that shall be sealed with a minimum
1.5” wide heat weld.
Maximum Design
Pressure: -80 psf. (See General Limitation #9.)
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 10 of 34
Membrane Type: Single Ply, PVC
Deck Type 4I: Lightweight Concrete, Insulated
Deck Description: Min. 310 psi, 2” Elastizell Lightweight Insulating Concrete with Zell-Fibers
installed over 1” EPS holey board cast over structural concrete deck.
System Type A(3): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ENRGY 3, ENRGY 3 25 PSI, ValuTherm, ValuTherm 25 PSI, R-Panel, R-Panel 25 PSI,
ENRGY 3 AGF, ENRGY 3 AGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI,
ENRGY 3 CGF, ENRGY 3 CGF 25 PSI, ValuTherm CGF, ValuTherm CGF 25 PSI
Minimum 1.5” thick N/A N/A
Note: All insulation shall be adhered to the deck with JM Two-Part Roofing System Urethane
Insulation Adhesive or One Step Foamable Adhesive applied in ¾” – 1” wide ribbons spaced 12”
o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: JM PVC Membrane fully adhered to the insulation with JM PVC Membrane
Adhesive (Low VOC) applied at a rate of 0.83 gal/sq.on both membrane and the
substrate. with the minimum 2.5” wide side laps that shall be sealed with a
minimum 1.5” wide heat weld.
Maximum Design
Pressure: -130 psf. (See General Limitation #9.)
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 11 of 34
Membrane Type: Single Ply, PVC
Deck Type 4I: Lightweight Concrete, Insulated
Deck Description: Min. 310 psi, 2” Elastizell Lightweight Insulating Concrete with Zell-Fibers
installed over 1” EPS holey board cast over structural concrete deck.
System Type A(4): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ENRGY 3, ENRGY 3 25 PSI, ValuTherm, ValuTherm 25 PSI, R-Panel, R-Panel 25 PSI,
ENRGY 3 AGF, ENRGY 3 AGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI,
ENRGY 3 CGF, ENRGY 3 CGF 25 PSI, ValuTherm CGF, ValuTherm CGF 25 PSI
Minimum 1.5” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
JM SECUROCK Gypsum‐Fiber Roof Board
Minimum ¼” thick N/A N/A
Note: All insulation shall be adhered to the deck with JM Two-Part Urethane Insulation Adhesive
or One Step Foamable Adhesive applied in ¾” – 1” wide ribbons spaced 12” o.c or JM Roofing
System Urethane Adhesive applied in ½ - ¾ ” ribbons spaced 12” o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: JM PVC Membrane fully adhered to the insulation with JM PVC Membrane
Adhesive (Low VOC) applied at a rate of 0.83 gal/sq on both membrane and the
substrate. The minimum 2.5” wide side laps that shall be sealed with a minimum
1.5” wide heat weld.
Maximum Design
Pressure: -130 psf. (See General Limitation #9.)
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 12 of 34
Membrane Type: Single ply, PVC
Deck Type 4: Lightweight Concrete, Non-insulated
Deck Description: Min. 300 psi Celcore MF with Celcore HS Rheology Modifying Admixture; Min.
1/8” slurry coat; Min. 1” EPS board; Min. 2” top coating with Celcore PVA curing
compound cast over cementitious wood fiber or structural concrete
System Type E(1): Base sheet mechanically fastened.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Sheet: One ply of DynaFast 180 S mechanically fastened with min. 1.8” Trufast Twin-
Loc Nail Batten Fastener & Trufast Twin Loc Coiled Batten Bar spaced 6" o.c.
within the 4" wide torch welded side laps.
Membrane: JM PVC Fleece Backed applied with approved mopping asphalt at an application
rate of 20-40 lbs./sq. with minimum 4” wide side laps that shall be sealed with a
minimum 1.5” wide heat weld.
Maximum Design
Pressure: -60 psf. (See General Limitation #9.)
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 13 of 34
Membrane Type: Single ply, PVC
Deck Type 4: Lightweight Concrete, Non-insulated
Deck Description: Min. 300 psi Celcore MF with Celcore HS Rheology Modifying Admixture; Min.
1/8” slurry coat; Min. 1” EPS board; Min. 2” top coating with Celcore PVA curing
compound cast over Min. 22 ga., vented Type B, Grade 33 steel deck attached to
structural supports spaced a maximum 5-ft o.c. with 5/8” puddle welds at each flute.
Steel deck side laps stitched with 1/4”-14 HWH screws at a maximum 15” o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Deck
Stress Analysis Table
System Type E(2): Base sheet mechanically fastened.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not
approved and shall not be installed unless said accessories demonstrate compliance with prescriptive
Florida Building Code requirements and are field fabricated utilizing the approved membranes
listed in Table 1.
Base Sheet: One ply of DynaFast 180 S mechanically fastened with min. 1.8” Trufast Twin-Loc
Nail Batten Fastener & Trufast Twin Loc Coiled Batten Bar spaced 6" o.c. within
the 4" wide torch welded side laps.
Membrane: JM PVC Fleece Backed applied with approved mopping asphalt at an application
rate of 20-40 lbs./sq. with minimum 4” wide side laps that shall be sealed with a
minimum 1.5” wide heat weld.
Maximum Design
Pressure: -60 psf. (See General Limitation #7.)
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 14 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Lightweight Insulating Concrete
System Type F(1): Membrane fully adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Deck: Minimum 22 ga., vented corrugated 1.5” WR Type B , Grade 40 steel fastened to
the 6’-0” o.c. steel supports with #12-24 Tek 5 SD screws. One screw per every
flute and fastened 6” o.c. to steel testing frame. Side laps of sheets fastened with
#12 SD screws 12” o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Deck
Stress Analysis Table
Lightweight
Concrete:
Lightweight Insulating Concrete with a minimum compressive strength of 330 psi,
and a MCRF of 233.614 lbf with 1.7” Lightweight Concrete (LWC) CR Base
Sheet Fasteners. A ¼” thick slurry of lightweight insulating concrete poured over
deck. One layer of EPS Dyplast with a density of 1.0 lb. firmly pressed into the
slurry. LWIC was poured over the EPS board to a thickness of 2” minimum.
Membrane: JM PVC Fleece Backed fully adhered to the deck with JM PVC Membrane
Adhesive (water-based) applied at a rate of 1 gal/sq. to the substrate and heat-
welded 3” side laps.
Maximum Design
Pressure: -90 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 15 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Lightweight Insulating Concrete
System Type F(2): Membrane fully adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Deck: Structural Concrete Deck
Lightweight
Concrete:
Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture
cast to a depth of 1/8” with a wet cast density of 49 lb./ft³ over sturctural concrete.
Minimum 1” thick EPS boardshall be placed into the wet concrete. Minimum 2”
thick Celcore MF Cellular Concrete with Celcore HS admixture with a wet cast
density of 44.6 lb./ft³ added as the top coat. Celcore PVA Curing Compound
applied over the top coat at a rate of 0.33 gal/sq.
Membrane: JM PVC Fleece Backed fully adhered to the deck with JM PVC Membrane
Adhesive (water-based) applied at a rate of 1 gal/sq. to the substrate with
minimum 2.5” wide side laps that shall be sealed with a minimum 1.5” wide heat
weld.
Maximum Design
Pressure: -367.5 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 16 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 380 psi Concrecel Cellular Lightweight Insulating Concrete cast over
structural concrete.
System Type F(3): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Membrane: JM PVC Fleece Backed Membrane adhered to the deck with MBR Low VOC
Membrane Adhesive applied at a rate of 2-2.5 gal/100ft2 with minimum 2.5” wide
side laps that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure:
-342.5 psf. (See General Limitation #9.)
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 17 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Minimum 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology
Modifying Admixture is laid with a 1/8” slurry coat with a minimum 1” EPS
Board and an additional 2” thick topcoat. Celcore PVA Curing compound applied
after top coat setting at 300 ft2/gal. cast over optional vapor barrier adhered to
structural concrete substrate. System Type F(4): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier:
(Optional)
DynaBase HW torch adhered to concrete substrate primed with ASTM D41
primer followed by Celcore lightweight insulating concrete cast over the adhered
membrane.
Membrane: JM PVC Fleece Backed adhered with JM Roofing System Urethane Adhesive
applied in ½” - 3/4” ribbons spaced 4” o.c. with minimum 2.5” wide side laps that
shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -257.5 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 18 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Minimum 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology
Modifying Admixture is laid with a 1/8” slurry coat with a minimum 1” EPS Board
and an additional 2” thick topcoat. Celcore PVA Curing compound applied after
top coat setting at 300 ft2/gal. cast over cementitious wood fiber substrate.
System Type F(5): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Membrane: JM PVC Fleece Backed adhered to the deck per one of the following:
Option #1: Membrane adhered to the deck with JM Roofing System Urethane Adhesive
applied in ½” - 3/4” ribbons 4” o.c. with minimum 2.5” wide side laps that shall be
sealed with a minimum 1.5” wide heat weld.
Maximum Design Pressure: -197.5 psf. (See General Limitation #9.)
Option #2: Membrane adhered to the deck with JM Roofing System Urethane Adhesive
applied in ½” - 3/4” ribbons 12” o.c. with minimum 2.5” wide side laps that shall
be sealed with a minimum 1.5” wide heat weld.
Maximum Design Pressure: -167.5 psf. (See General Limitation #9.)
Maximum Design
Pressure: See Options Above
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 19 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 300 psi Celcore MF with Celcore HS Rheology Modifying Admixture; Min.
1/8” slurry coat; Min. 1” EPS board; Min. 2” top coating with PVA curing
compound cast Min. 22 ga., vented Type B, Grade 33 steel deck attached to
structural supports spaced a maximum 5-ft o.c. with 5/8” puddle welds at each flute.
Steel deck side laps stitched with 1/4”-14 HWH screws at a maximum 15” o.c.
This Tested Assembly has been analyzed for allowable deck stress. See Deck
Stress Analysis Table
System Type F(6): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not
approved and shall not be installed unless said accessories demonstrate compliance with prescriptive
Florida Building Code requirements and are field fabricated utilizing the approved membranes
listed in Table 1.
Membrane: JM PVC Fleece Backed adhered to the deck per one of the following:
Option #1: Membrane adhered to the deck with JM Roofing System Urethane Adhesive applied
in ½” - 3/4” ribbons 4” o.c. with minimum 2.5” wide side laps that shall be sealed
with a minimum 1.5” wide heat weld.
Option #2: Membrane adhered to the deck with JM Roofing System Urethane Adhesive applied
in ½” - 3/4” ribbons 12” o.c. with minimum 2.5” wide side laps that shall be sealed
with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -60 psf. (See General Limitation #7.)
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 20 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 300 psi Concrecel Cellular Lightweight Insulating Concrete cast over
structural concrete deck.
System Type F(7): Membrane fully adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Membrane: JM PVC Fleece Backed fully adhered to the deck with Millennium Hurricane
Force 1-Part Membrane Adhesive at a rate of 2-2.5 gal/100ft2 with minimum 2.5”
wide side laps that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -342.5 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 21 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 568 psi, 2” Elastizell Lightweight Insulating Concrete with Zell-Fibers cast
over structural concrete
System Type F(8): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Sheet: DynaBase adhered with JM MBR RA Membrane Adhesive applied in ½-¾” wide
ribbons spaced 12” o.c. with a 4” side lap.
Membrane: JM PVC Fleece Backed membrane is adhered with JM Roofing System Urethane
Adhesive applied in ½-¾” wide ribbons spaced 12” o.c. with minimum 2.5” wide
side laps that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -136 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 22 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 568 psi, 2” Elastizell Lightweight Insulating Concrete with Zell-Fibers cast
over structural concrete
System Type F(9): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Sheet: DynaBase adhered with Millennium Hurricane Force Membrane Adhesive applied
in ½-¾” wide ribbons spaced 6” o.c. with a 4” side lap.
Membrane: JM PVC Fleece Backed membrane is adhered with JM Roofing System Urethane
Adhesive applied in ½-¾” wide ribbons spaced 6” o.c. with minimum 2.5” wide
side laps that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -192.5 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 23 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 568 psi, 2” Elastizell Lightweight Insulating Concrete with Zell-Fibers cast
over an optional vapor barrier adhered to structural concrete substrate.
System Type F(10): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier:
(Optional)
DynaBase HW torch adhered to concrete substrate primed with JM Asphalt Primer
(ASTM D41 Type II) followed by Elastizell lightweight insulating concrete cast
over the adhered membrane.
Maximum Design Pressure: -52.5 psf. (See General Limitation #9.)
Membrane: JM PVC Fleece Backed membrane is adhered with JM Roofing System Urethane
Adhesive applied in ½-¾” wide ribbons spaced 12” o.c. with minimum 2.5” wide
side laps that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -177.5 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 24 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 568 psi, 2” Elastizell Lightweight Insulating Concrete with Zell-Fibers cast
over structural concrete
System Type F(11): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Membrane: JM PVC Fleece Backed membrane is fully with JM Roofing System Urethane
Adhesive applied in ½-¾” wide ribbons spaced 6” o.c. with minimum 2.5” wide
side laps that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -225 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 25 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 300 psi Celcore MF with Celcore HS Rheology Modifying Admixture; Min.
1/8” slurry coat; Min. 1” EPS board; Min. 2” top coating with PVA curing
compound cast over cementitious wood fiber or structural concrete. System Type F(12): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base sheet: DynaBase adhered with Millennium Hurricane Force Membrane Adhesive applied
in 1” wide ribbons spaced 6” o.c. with a 4” side lap.
Membrane: JM PVC Fleece Backed adhered to the deck with JM Roofing System Urethane
Adhesive applied in ½” - 3/4” ribbons 6” o.c. with minimum 2.5” wide side laps
that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design -117.5 psf. LWC over cementitious wood fiber (See General Limitation #9).
Pressure: -192.5 psf. LWC over concrete (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 26 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 300 psi Celcore MF with Celcore HS Rheology Modifying Admixture; Min.
1/8” slurry coat; Min. 1” EPS board; Min. 2” top coating with PVA curing
compound cast over cementitious wood fiber or structural concrete.
System Type F(13): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base sheet: DynaBase adhered with Millennium Hurricane Force Membrane Adhesive applied
in 1” wide ribbons spaced 12” o.c. with a 4” side lap.
Membrane: JM PVC Fleece Backed adhered to the deck with JM Roofing System Urethane
Adhesive applied in ½” - 3/4” ribbons 12” o.c. with minimum 2.5” wide side laps
that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -117.5 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 27 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 383.5 psi Celcore lightweight insulating concrete cast over 22 ga. Grade 90
vented type B galvanized steel.
System Type F(14): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Membrane: JM PVC Fleece Backed membrane adhered to the deck with JM Roofng System
Urethane Adhesive applied in ½” - 3/4” ribbons 6” o.c. with minimum 2.5” wide
side laps that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -204.5 psf (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 28 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 383.5 psi Celcore lightweight insulating concrete cast over optional vapor
barrier or directly onto primed structural concrete.
System Type F(15): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier:
(Optional)
Option #1:
DynaBase HW torch adhered to concrete substrate primed with JM Asphalt Primer
(ASTM D41 Type II) followed by Celcore lightweight insulating concrete cast
over the adhered membrane.
Maximum Design Pressure: -262.5 psf. (See General Limitation #9.)
Option #2:
JM Vapor Barrier SA adhered to concrete substrate primed with JM Asphalt
Primer (ASTM D41 Type II) followed by Celcore lightweight insulating concrete
cast over the adhered membrane.
Maximum Design Pressure: -90 psf. (See General Limitation #9.)
Membrane: JM PVC Fleece Backed Membrane adhered with JM Roofng System Urethane
Adhesive applied in ½” - 3/4” ribbons 6” o.c. with minimum 2.5” wide side laps
that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design Pressure: -502.5 psf. (See General Limitation #9.)
Maximum Design
Pressure: See Options Above
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 29 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 383.5 psi Celcore lightweight insulating concrete cast over primed structural
concrete.
System Type F(16): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Membrane: JM PVC Fleece Backed Membrane adhered with JM Roofng System Urethane
Adhesive applied in ½” - 3/4” ribbons 12” o.c. with minimum 2.5” wide side laps
that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure:
-398 psf. (See General Limitation #9.)
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 30 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 370 psi Concrecel lightweight insulating concrete cast over 22 ga. Grade 90
vented type B galvanized steel.
System Type F(17): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Membrane: JM PVC Fleece Backed adhered to the deck with JM Roofng System Urethane
Adhesive applied in ½” - 3/4” ribbons 12” o.c. with minimum 2.5” wide side laps
that shall be sealed with a minimum 1.5” wide heat weld.
Maximum Design
Pressure: -82.5 psf. (See General Limitation #9).
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 31 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 370 psi Concrecel lightweight insulating concrete cast over structural
concrete.
System Type F(18): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Membrane: JM PVC Fleece Backed adhered to the deck per one of the following:
Option #1: Membrane adhered to the deck with JM Roofng System Urethane Adhesive
applied in ½” - 3/4” ribbons 6” o.c. with minimum 2.5” wide side laps that shall be
sealed with a minimum 1.5” wide heat weld.
Maximum Design Pressure: -480 psf. (See General Limitation #9.)
Option #2: Membrane adhered to the deck with JM Roofng System Urethane Adhesive
applied in ½” - 3/4” ribbons 12” o.c. with minimum 2.5” wide side laps that shall
be sealed with a minimum 1.5” wide heat weld.
Maximum Design Pressure: -343.5 psf. (See General Limitation #9.)
Maximum Design
Pressure: See Options Above
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 32 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 213.5 psi Elastizell lightweight insulating concrete cast over an optional
vapor barrier adhered to structural concrete substrate.
System Type F(19): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier:
(Optional)
DynaBase HW torch adhered to concrete substrate primed with JM Asphalt Primer
(ASTM D41 Type II) followed by Elastizell lightweight insulating concrete cast
over the adhered membrane.
Maximum Design Pressure: -52.5 psf. (See General Limitation #9.)
Membrane: JM PVC Fleece Backed adhered per one of the following:
Option #1: Membrane adhered with JM Roofng System Urethane Adhesive applied in ½” -
3/4” ribbons 4” o.c. with minimum 2.5” wide side laps that shall be sealed with a
minimum 1.5” wide heat weld.
Maximum Design Pressure: -390 psf. (See General Limitation #9.)
Option #2: Membrane adhered with JM Roofng System Urethane Adhesive applied in ½” -
3/4” ribbons 6” o.c. with minimum 2.5” wide side laps that shall be sealed with a
minimum 1.5” wide heat weld.
Maximum Design Pressure: -67.5 psf. (See General Limitation #9.)
Option #3: Membrane adhered with JM Roofng System Urethane Adhesive applied in ½” -
3/4” ribbons 12” o.c. with minimum 2.5” wide side laps that shall be sealed with a
minimum 1.5” wide heat weld.
Maximum Design Pressure: -90 psf. (See General Limitation #9.)
Maximum Design
Pressure: See Options Above
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 33 of 34
Membrane Type: Single Ply, PVC
Deck Type 4: Lightweight Concrete
Deck Description: Min. 213.5 psi Elastizell lightweight insulating concrete cast over 22 ga., Grade
90, vented type B galvanized steel.
System Type F(20): Membrane adhered to deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Membrane: JM PVC Fleece Backed adhered to the deck per one of the following:
Option #1: Membrane adhered to the deck with JM Roofng System Urethane Adhesive
applied in ½” - 3/4” ribbons 6” o.c. with minimum 2.5” wide side laps that shall be
sealed with a minimum 1.5” wide heat weld.
Maximum Design Pressure: -300 psf. (See General Limitation #9.)
Option #2: Membrane adhered to the deck with JM Roofng System Urethane Adhesive
applied in ½” - 3/4” ribbons 12” o.c. with minimum 2.5” wide side laps that shall
be sealed with a minimum 1.5” wide heat weld.
Maximum Design Pressure: -217.5 psf. (See General Limitation #9.)
Maximum Design
Pressure: See Options Above
NOA No.: 17-0427.05
Expiration Date: 12/06/22
Approval Date: 12/07/17
Page 34 of 34
LIGHTWEIGHT INSULATING CONCRETE SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal
resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and
fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard
RAS 117 and/or RAS 137, calculations shall be signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant. 2. For steel deck application where specific deck construction is not referenced: The deck shall be a minimum 22 gage
attached with 5/8” puddle welds with weld washers at every flute with maximum deck spans of 5 ft. o.c. 3. For systems where specific lightweight insulating concrete is not referenced, the minimum design mix shall be a minimum
of 300 psi.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings
of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be
4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when
the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with
approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one
down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6"
break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at
a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45
psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in
compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf.
Insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared,
signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing
Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within
this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and
corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure
zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA,
General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule
61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE