product catalog - tione dental 101...dental implant body specimen holder 30 tione fatigue test of...

36
Product Catalog

Upload: others

Post on 10-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Product Catalog

Page 2: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

contents

16

18

18

24

29

32

33

31

26

21

21

Screwman Abutment

Ball Type Abutment

Surgical Kit

101 Standard Surgical Kit

101 Premium Surgical Kit

Try-in Kit

Prosthetic Kit

Bone Condenser Kit

Other Kit

Ball Type Abutment Impression Components

Screwman Open / Closed Tray Impression Components

Open / Closed Tray Impression Components1

3

4

9

11

14

15

13

10

5

Narrow / Ti-Base Abutment / Caster Abutment(UCLA)

Temporary Abutment / Center / Special Screw

SLAffinity® Surface Treatment

SLAffinity® In Vivo Test

Long Cover / Healing Screw

Healing & Abutment

TIONE 101

S-1 Abutment / S-2 Abutment

Fatigue Test

Implant

Impression Components

Angled / Smiler Abutment

Please carefully read this catalogue before using TIONE Implant

System, and make sure to follow each step during operation.

If you are new TIONE user, we recommend you to attend the TIONE

training course or contact our professionals before using our products.

Warning: TIONE product usage is only limited to medical professionals.

Page 3: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

1

X6,500X3,000 X33,000

Exclusively Patented Surface TreatmentBy using special SLA surface treatment (Sand-blasting , Large-gritting) , the

implant surface can have more roughness which increases the contact area

between bone and the implant , creating 1~1.5µm porosity . After the SLA ,

the special electric-chemical treatment is conducted to add the thickness of

oxide layer on the surface, forming improved porosity that helps osteoblast

cells to attach , bringing greater hydrophilicity . The SLAffinity implant can

quickly absorb the protein and growth factor, brining outstanding osseointe-

gration performance within shorter healing time.

Because of SLAffinity surface treatment , the osteoblast cells will be effec-

tively guided to fix and grow on the implant surface.

Nanometer scale surface roughness

Page 4: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

® Production Process

MaterialGrade 4 Titanium from Germany (ISO 5832)

CNC MachiningThe precise CNC machining process is to transform the Grade 4 Titanium bar into the shape of dental implant.

Sand Blasting & Large GrittingImpact the surface of implant by aluminum oxide sand at high pressure and velocity, creating micrometer size (20~40µm) porosity.

Acid-EtchingStrong acid is used to etch the surface of implant after sand blasting and large gritting, to improve the roughness to sub-micron (1~4µm) size porosity.

Electro-ChemicalPlace the implant into electrolytic solution, and supply the electricity to create titanium oxide layer with additional nanometer size (under 200nm) porosity on the implant surface.

2

Page 5: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Machine SLA SLAffinity®

According to the research data (Figure 1) from Taipei Medical Univer-

sity, three kinds of implants with different surface treatment: no surface

treatment, SLA, SLAffinity were inserted into the animal bone for 3, 6,

12 weeks separately. To remove these implants, the one with SLAffini-

ty surface treatment needed the torque up to 128.1 N-cm, which is the

highest.

It can be proved that implant with SLAffinity hydrophilic surface treat-

ment brings fast and outstanding osseointegration performance.

3 weeks 6 weeks 12 weeks

150

112.5

75

37.5

0

Rem

ove

Torq

ue(N

-cm

)

SL

A

SL

Affin

ity ®

Ma

ch

ine

Osteointegration

new Bone

Bone

High Hydrophilic performanceThe surface treated with SLAffinity® has a capillary surface.

When the blood contacts the surface of the implant, it effec-

tively guides the osteoblast to a stable state and firmly

adheres to the growth. (Figure 2)

Figure 2. High Hydrophilic performance

3

SLAffinity® In Vivo Test

Figure 1. Research Data from Taipei Medical University

Page 6: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

LoadingFrequency 14Hz

Loading Device

Hemispherical Loading Member

AbutmentDental Implant Body

Specimen Holder

30°

TIONE Fatigue test of artificial root with a minimum diameter of

Ø3.5 (Fig. 3). According to the data, the root is in compliance

with the ISO 14801 system fatigue test range. At frequencies

below 15 Hz, it passes the test of 5 million times above 270N.

Shows the safety and reliability of the TIONE implant system in

clinical use.

Cycles

Lo

ad

ing

(N)

Cortical Cancellous

Stress Distribution Analysis

Figure 3. The fatigue curve of dynamic fatigue test

Fatigue Test

4

Page 7: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

5

TIONE 101 is made of the medical grade-Grade 4 pure titanium from Germany in collar expansion and wide diameter design by utilizing the automated precision CNC machining system from Japan and with exclusively patented surface treatment SLAffini-ty supported by numerous of clinical cases bring optimal results; moreover by passing the absolutely accurate test and quality system in strictly mechanical test and fatigue test of 5 million times/ 300N-cm and passing through ultrasonic cleaning process with ultrapure water to enable ultimate sterilized products and no residues left on products. All sanitarily packed products are at the Class 1000 clean room to ensure the best quality delivered to patients.

High Bone Density

Osseointegration ability

Loading torque

Loading speed

Operation efficiency

Low High

Multiple Choice of Diameter Ø3.5 ~ Ø7.0Two Pieces DesignSLAffinity Surface Treatment Grade 4 TitaniumInternal Hexagon, Morse Taper 11 Degree DesignPlatform SwitchingSmooth Tapper, Collar ExpansionMedical Device No. 004488

Page 8: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

• Collar Expansion

• Self-Tapping

• Smooth Tapper

One Fit All Design-Unified Hex Internal Connection fits all abutments-Effective Inventory Management

6

Advanced Design-Platform Switching-Morse Taper 11˚-Internal Hexagon Deign

Collar Expansion-To protect the Maxillary Sinus Reduce the bone loss-To secure the implant lodging tightly in cortical bone

Smooth Tapper-Consistent Cutting Power-Self-tapping Thread Design

Page 9: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

7

Ø6.0mmØ5.0mm

Ø3.5mm

101 SYSTEM Cover Screw Grade 4 Titanium / Sterilized

8.09.5

14.0

HF01-103508HF01-103595HF01-103511HF01-103514

L

11.0

3.53.5

3.5

D

3.5

REF

7.08.0

11.0

HF01-106007HF01-106008HF01-106095HF01-106011

L

9.5

6.06.0

6.0

D

6.0

REF7.08.0

11.0

HF01-107007HF01-107008HF01-107095HF01-107011

L

9.5

7.07.0

7.0

D

7.0

REF

8.09.5

14.0

HF01-104008HF01-104095HF01-104011HF01-104014

L

11.0

4.04.0

4.0

D

4.0

REF7.08.0

11.0

HF01-104507HF01-104508HF01-104595HF01-104511

L

9.5

4.54.5

4.514.0 HF01-1045144.5

D

4.5

REF

7.08.0

11.0

HF01-105007HF01-105008HF01-105095HF01-105011

L

9.5

5.05.0

5.014.0 HF01-1050145.0

D

5.0

REF

L

L L L

D

D D D

L

D

L

D

Color management system:D3.5mm

L x.xmm

D4.0mm

L x.xmm

D4.5mm

L x.xmm

D5.0mm

L x.xmm

D6.0mm

L x.xmm

D7.0mm

L x.xmm

Ø7.0mm

Ø4.0mm Ø4.5mm

※ It is recommended to use at least Ø4.5 implants for the tooth position after Pre-Molar. All spec. in mmD : DiameterL : Total LengthREF: Reference Number

Note

Page 10: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

P R O S T H E T I C SHealing Screw/ Abutment / Impressin Coping Component/ Impression Procedure

8

Page 11: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

HF05-322235HF05-323050

HF05-322035

G 1.0 4.0

H REF

4.05.5

2.03.0

HF05-3240707.54.0

D 5.55.55.55.5

HG

D

H

D

HF05-304520HF05-305520HF05-306520

D REFH 4.55.56.5

2.02.02.0

HF05-351035HF05-352035HF05-353050

1.0 4.0H

4.05.5

2.03.0

HF05-3540707.54.0

REFG3.53.53.53.5

D

D

HG

HF05-342035HF05-342235HF05-343050

1.0 4.0H

4.05.5

2.03.0

HF05-3440707.54.0

REFG4.04.04.04.0

D

D

HG

HF05-312035HF05-312235HF05-313050

G1.0 4.0

H

4.05.5

2.03.0

HF05-3140707.54.0

REF4.54.54.54.5

D

D

HG

HG

D

HF05-332235HF05-333050

HF05-332035G

1.0 4.0H

4.05.5

2.03.0

REF

HF05-3340707.54.0

D 6.56.56.56.5

Designed to prevent soft tissue for better aesthetic restorations Anodization Recommended Torque (5~15 N-cm)Grade 4 Titanium/ Disposable / Non-Sterilized

Shaping Gingiva Anodizatin/ Color Code Management Recommended Torque (5~15 N-cm)Grade 4 Titanium/ Disposable / Non-Sterilized

All spec. in mmD : DiameterG : Gingava Height H : Height REF: Reference Number

Note

9

Healing Screw

Long Cover Screw

Page 12: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

S-1 Abutment

S-2 Abutment Central Screw included Recommended Torque (30~35 N-cm) Anodization Grade 4 Titanium / Non-Sterilized

Recommended Torque (30~35 N-cm) Anodization Grade 4 Titanium / Thread M2.0 / Non-Sterilized

All spec. in mmD : DiameterG : Gingava Height Ab.H: Abutment HieghtREF : Reference Number

Note

10

G0.51.53.0

REFHF05-220540HF05-221540HF05-223040

4.5 HF05-224540

0.5 HF05-2205601.5 HF05-2215603.0 HF05-2230604.5 HF05-224560

D6.56.56.56.5

6.56.56.56.5

G

D

Ab.H

G REF0.51.5

3.0

HF05-720540HF05-721540

HF05-7230404.5 HF05-7245400.5 HF05-7205601.5 HF05-7215603.0 HF05-7230604.5 HF05-724560

D6.56.5

6.56.56.56.56.56.5

G

D

Ab.H

4.04.04.0

Ab.H

4.06.06.06.06.0

Ab.H4.04.04.04.0

6.06.06.06.0

GHF05-210540

REF0.51.53.0

HF05-211540HF05-213040

4.5 HF05-214540

0.5 HF05-2105601.5 HF05-211560

3.0 HF05-2130604.5 HF05-214560

D5.55.55.55.5

5.55.5

5.55.5

G

D

Ab.H

G REF0.51.53.0

HF05-710540HF05-711540HF05-713040

4.5 HF05-7145400.5 HF05-7105601.5 HF05-7115603.0 HF05-7130604.5 HF05-714560

D5.55.55.55.55.55.55.55.5

G

D

Ab.H

4.04.04.0

Ab.H

4.06.06.06.06.0

Ab.H4.04.04.04.0

6.06.0

6.06.0

G

D

Ab.H

G REFHF05-2005400.5

1.5

3.0

HF05-201540

HF05-2030404.5 HF05-2045400.5 HF05-2005601.5 HF05-2015603.0 HF05-2030604.5 HF05-204560

4.54.5

4.5

D

4.54.54.54.54.5

G REFHF05-7005400.5

1.53.0

HF05-701540HF05-703040

4.5 HF05-7045400.5 HF05-7005601.5 HF05-7015603.0 HF05-7030604.5 HF05-704560

D4.54.54.54.54.54.54.54.5

G

D

Ab.H

4.04.04.0

Ab.H

4.06.06.06.06.0

4.04.0

4.0

Ab.H

4.06.06.06.06.0

Page 13: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Abutment Impression Coping

Abutment Analog

4.55.56.5

4.04.04.0

HF01-424540HF01-425540HF01-426540

4.55.56.5

6.06.06.0

HF01-424560HF01-425560HF01-426560

D REFAb.H

Standard Abutment Impression Coping

D Ab.H REF4.55.56.5

4.04.04.0

HF01-404510HF01-405510HF01-406510

4.5 6.0 HF01-4045115.5 6.0 HF01-4055116.5 6.0 HF01-406511

Temporary Cap

HF01-414505HF01-415505HF01-416505

D Ab.H REF4.55.56.5

4.04.04.0

HF01-4145074.5 6.0HF01-4155075.5 6.0HF01-4165076.5 6.0

Wax-Up Coping (Single)D Ab.H REF

4.55.56.5

4.04.04.0

HF01-434510HF01-435510HF01-436510

4.5 6.0 HF01-4345115.5 6.0 HF01-4355116.5 6.0 HF01-436511

D REF4.55.56.5

HF01-444511HF01-445511HF01-446511

Wax-Up Coping (Bridge)

D

D 4.5 D 5.5 D 6.5

Ab.H4.0

Ab.H6.0 Ab.H

Plastic/ Disposable

D 4.5 D 5.5 D 6.5

Ab.H

Titanium/ Disposable

D 4.5 D 5.5 D 6.5

Ab.H

Plastic/ Disposable

D 4.5 D 5.5 D 6.5

Plastic/ Disposable

Ab.H4.0

Ab.H6.0

D 4.5 D 5.5 D 6.5

Ab.H

Plastic/ Disposable

D

D

D

D

All spec. in mmD : DiameterAb.H: Abutment HieghtREF : Reference Number

Note

11

Page 14: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

12

Impression Procedure

Single

Bridge

Wax-Up CopingImpression Coping Prosthesis Fabrication Cementation

S1 Abutment

Abutment Analog

S2 Abutment

Page 15: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Smiler Abutment

HF05-244530HF05-245515HF05-245530HF05-246515

HF05-244515

D GB GT REF4.54.55.55.56.56.5 HF05-246530

1.53.01.53.01.53.0

2.54.02.54.02.54.0

GTGB

D

All spec. in mmD : Diameter G : Gingava Height A : AngleGB : Gingiva ButtomGT : Gingiva TopREF : Reference Number

Note

13

HF05-234514

HF05-234511D G REF

4.5

4.5

1.5

1.5HF05-234521

HF05-2345134.5

4.5

1.5

2.5HF05-2345224.5 2.5HF05-2345234.5 2.5

HF05-2345124.5 3.5HF05-2345204.5 3.5

HF05-2345274.5 3.5

D

G

HF05-235514

HF05-235511D G REF

5.5

5.5HF05-235521

HF05-2355135.5

5.5HF05-2355225.5HF05-2355235.5HF05-2355125.5HF05-2355205.5HF05-2355275.5

1.5

1.51.5

2.52.52.53.53.53.5

Angled Abutment Central Screw included Recommended Torque (30~35 N-cm) Anodization Grade 4 Titanium / Non-Sterilized

Central Screw included Recommended Torque (30~35 N-cm) Anodization Grade 4 Titanium / Non-Sterilized

D

G

12.5°

27.5°20°

12.5°20°

27.5°

12.5°20°

27.5°

12.5°

27.5°20°

12.5°20°

27.5°12.5°20°

27.5°

HF02-2345354.5 3.5 HF02-2355355.5 3.535° 35°

Page 16: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Caster Abutment (UCLA)

HF01-254510D G Ab.H REF

4.5 1.0 11.0

G

Ab.H

D

14

Narrow Abutment

HF05-283511HF05-284008HF05-284011

HF05-283508

D G Ab.H REF3.53.54.04.0

1.51.51.51.5

6.59.56.59.5

Ab.H

G

D

Central Screw included Recommended Torque (30~35 N-cm) Gold Alloy / Non-Sterilized

All spec. in mmD : Diameter G : Gingava Height Ab.H : Abutment HieghtType : TypeREF : Reference Number

Note

Ab.H

Hex

D

4.0 HexD REF

4.0 HF05-290540Ab.H Type

Ab.H

Non-Hex

D

4.0 Non-HexD REF

4.0 HF05-290541Ab.H Type

Ti-Base Abutment

Central Screw included Recommended Torque (30~35 N-cm) Anodization Grade 4 Titanium / Non-Sterilized

Central Screw included Recommended Torque (30~35 N-cm) Grade 4 Titanium / Non-Sterilized

Page 17: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

All spec. in mmD : Diameter Ab.H : Abutment HieghtType : TypeREF : Reference Number

Note

Center Screw / Special Screw

15

HF05-263516D Ab.H REFType

3.5 9.0

D

Ab.H

Hex

HexHF05-2640164.0 9.0 HexHF05-2645164.5 9.0 HexHF05-2655165.5 9.0 HexHF05-2665166.5 9.0 Hex

D Ab.H REFHF05-2635153.5 9.0 Non-HexHF05-2640154.0 9.0 Non-HexHF05-2645154.5 9.0 Non-HexHF05-2655155.5 9.0 Non-HexHF05-2665156.5 9.0 Non-Hex

Type

D

Ab.H

Non-Hex

Temporary Abutment

REFCenter Screw HF01-282390

REFSpecial Screw HF01-560001

0.2mm

Central Screw included Recommended Torque (30~35 N-cm) Grade 4 Titanium / Non-Sterilized

Recommended Torque (30~35 N-cm) Grade 4 Titanium / Non-Sterilized

Page 18: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Open/ Closed Tray impression component

HF01-504003HF01-503503

D S/L REF

3.54.0

SS

HF01-5045034.5 SHF01-5055035.5 SHF01-5065036.5 S

HF01-503505HF01-504005

D S/L REF

3.54.0

LL

HF01-5045054.5 LHF01-5055055.5 LHF01-5065056.5 L

D

S/L

Open Tray

HF01-514003HF01-513503

D S/L REF

3.54.0

SS

HF01-5145034.5 SHF01-5155035.5 SHF01-5165036.5 S

HF01-513505HF01-514005

D S/L REF

3.54.0

LL

HF01-5145054.5 LHF01-5155055.5 LHF01-5165056.5 L

D

S/L

Closed Tray

L REF14.0

D4.0 HF01-550014 Titanium/ Disposable/ Non-Sterilized

L

D

Implant Analog

Scanbody

HT02-124008D H REF

4.0 10.75

D

H

S:23mm / L:27mm

S:18mm / L:22mm

16

All spec. in mm D : Diameter S/L : Short / Long H : Height L : Total Length REF: Reference Number

Note

Transger Pin included Stainless Steel / Disposable / Non-Sterilized

Transger Pin included Stainless Steel / Disposable / Non-Sterilized

Central Screw included Recommended Torque (30~35 N-cm) Grade 4 Titanium / Non-Sterilized

Page 19: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Prosthesis Fabrication Cementation

Open/ Closed Tray Impression Procedure

Open Tray / Transfer Pin

Closed Tray / Transfer Pin

Implant Analog Narrow Abutment

Angled Abutment

Smiler Abutment

S2 Abutment

Caster Abutment (UCLA)

Temporary Abutment

Ti-Base Abutment

17

Page 20: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Screwman Open/Closed Tray Impression ComponentsScrewman Open Tray

HF01-525514HF01-524514

D S/L REF4.55.5

SS

HF01-524518HF01-525518

D S/L REF4.55.5

LL

HF01-535509HF01-5345094.5

5.5SS

Screwman Closed Tray D S/L REF

HF01-534512HF01-535512

4.55.5

LL

D S/L REF

S/L

D

S/L

D

S:11mm / L:18mm

S:9mm / L:12mm

Screwman Abutment

G

D

1.5

0.54.5

4.5 HF05-2745153.04.5 HF05-2745304.54.5 HF05-274545

HF05-274505G REFD

0.55.5 HF05-275505

1.55.5 HF05-2755153.05.5 HF05-2755304.55.5 HF05-275545

G REFD

G

D

18

Aluminum alloy / Disposable / Non-Sterilized D 4.5 D 5.5

Screwman Analog

HF01-464512HF01-465512

4.5 12125.5

D REFL

DL

All spec. in mmD : Diameter G : Gingava Height S/L : Short / Long L : Total Length REF: Reference Number

Note

Delivery Holder included Recommended Torque (30~35 N-cm) Anodization Grade 4 Titanium / Threaded

Transfer Pin included Stainless Steel / Disposable / Non-Sterilized

Transfer Pin included Stainless Steel / Disposable / Non-Sterilized

Page 21: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

All spec. in mm D : Diameter M : Thread Outter DiameterH : Height Ab.H : Abutment HieghtType : Type REF : Reference Number

Note

Screwman Open/Closed Tray Impression Components

D

D 4.5 D 5.5

Hex

D 4.5 D 5.5

Non-Hex

HF01-475511HF01-474511

D Type REF4.55.5

Single / HexSingle / Hex

HF01-484511HF01-485511

D Type REF4.55.5

Bridge / Non-HexBridge / Non-Hex

Screwman Wax-Up Coping (Single)

Ti-Retaining Screw

HF01-462010HF01-462005

M H REF2.02.0

0.81.8

Temporary Cap

HF01-414505HF01-415505

D Ab.H REF4.55.5

4.04.0

HF01-4145074.5 6.0HF01-4155075.5 6.0 D 4.5 D 5.5

Ab.H

D

Screwman Wax-Up Coping (Bridge)

D

D

Ti-Retaining Screw included Plastic / Disposable / Non-Sterilized

Ti-Retaining Screw included Plastic / Disposable / Non-Sterilized

Plastic / Disposable / Non-Sterilized

Grade 4 Titanium / Non-Sterilized

19

M

H

0.8mm

Page 22: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

20

Screwman Abutment Impression Procedure

Screwman Abutment

Screwman Closed Tray

Screwman Analog Wax-Up Coping

Single (Hex)

Bridge (Non-hex)

Prosthesis Fabrication

or

or

Screwman Open Tray

Page 23: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

All spec. in mm D : Diameter G : Gingava Height H : Height Type : Type REF : Reference Number

Note

Ball Type Abutment

3.04.5

1.54.04.04.0

Ball Type Abutment Impression Components

HF05-104530HF05-104545

HF05-104515G REF D

G

D

HF01-540002

Ball Type AnalogREF

L

Transfer Cap Transfer Cap included / Disposable / Non-Sterilized

D

D

D

5.55.5 HF01-540005

HF01-540004

O-ring CapREFD

14.06.0LD

Standard / Gray Tight / Blue

Standard / GrayTight / Blue Oring included / Disposable / Non-Sterilized

Type

4.54.5 HF01-540006

HF01-540003

O-ringREF D

Standard / Gray / 5 Pcs SetTight / Blue / 5 Pcs Set Standard / Gray Tight / Blue Disposable / Non-Sterilized / 5 Pcs Set

Type

Delivery Holder included Recommended Torque (30~35 N-cm) Anodization Grade 4 Titanium Threaded / Non-Sterilized

21

Page 24: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Ball Type Abutment Impression Procedure

Ball Type Abutment Transfer Cap Ball Type Abutment Analog Ball Type Abutment to Overdenture

22

Page 25: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

23

S U R G I C A L K I T101 Standard Surgical Kit │ 101 Premium Surgical Kit │ Try-in Kit │ Prosthetic Kit │ Removal Kit │ Bone Condenser

Page 26: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

24

101 Standard Surgical Kit

101 Standard Surgical Kit

D 3.1 HT02-080001

D 3.4 HT02-080005

D 3.9 HT02-080009

D 4.4 HT02-080013

D 5.4 HT02-080017

D 2.0

D 2.3

HT02-040001

HT02-050001

D 2.8 HT02-050005

L L

L

L

L

LL

L

Product Name Quantity

D 3.5 HT01-100001

D 4.0 HT01-100002

D 4.5 HT01-100003

D 5.0 HT01-100004

D 7.0

D 6.0 HT01-100005

HT01-100006

Lance Drill 1256214222

Pilot DrillFinal Drill101 Countersink DrillPath PinDrill ExtenderGuide PinHex DriverRatchet Hex DriverRatchet Adapter

Product Name Quantity21

Handpiece AdapterTorque WrenchDepth Gauge 11

HT02-300002SPEC REF

31 Pcs Set

101 Standard Surgical Kit Surgical Kit Item List

All spec. in mm D : Diameter L : Total Length REF: Reference Number

Note

Final DrillLance Drill

Pilot Drill

101 Countersink LD REF

LD REF

LD REF D REF

Diamond-Like Coating Color-Code Management Sterilization at 134℃/18 min Stainless Steel

Diamond-Like Coating Color-Code Management Sterilization at 134℃/18 min Stainless Steel

Page 27: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

25

HT01-140001

HT01-140002

S

L

HT01-130001

HT01-130002

S

L

HT01-290003

HT01-290004

D 4.0

D 5.0

HT01-01000110/20/30/40 N-cm

HT01-160001

HT01-290001

SHT02-3000021 Case

HT01-150001

HT01-150002

S

L

HT01-180001

HT01-180002

S

L

HT01-090001

All spec. in mm D : Diameter S/L : Short / Long N : NewtonREF: Reference Number

Note

Torque Wrench

Depth Gauge

101 Standard Surgical Kit Case

Hex Driver

Ratchet Hex Driver

Ratchet Adapter

Handpiece Adapter

Drill Extender

Guide Pin

Path Pin

REF

S/L REF

D REF

S/L REF

S/L REF

REF

REF S/L REF

REF

N REF

Page 28: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

26

101 Premium Surgical Kit

101 Premium Surgical Kit

D 2.3 HT02-040006 LDM 2.3 D 2.3 L

L

11.0

9.5

8.0

HT02-050001

D 2.8 HT02-050005

D 2.3 HT02-050002

D 2.3 HT02-050003

D 2.3 HT02-050004

LD 2.0 HT02-040001L

HT02-300001SPEC REF

50 Pcs Set

101 Premium Surgical KitProduct Name QuantityLindemann Drill 1

156

1921422

Lance DrillPilot Drill101 Countersink DrillFinal DrillPath PinDrill ExtenderGuide PinHex DriverRatchet Hex Driver

Screwman Ratchet Hex Driver 1Handpiece Adapter 2Ratchet Adapter 2

1Torque Wrench1Depth Gauge

Surgical Kit Item List

All spec. in mm D : Diameter L : Total Length REF: Reference Number

Note

Product Name Quantity

Lindemann Drill Pilot DrillLance DrillLD REFLD REF LD REF

Diamond-Like Coating Color-Code Management Sterilization at 134℃/18 min Stainless Steel

Diamond-Like Coating Color-Code Management Sterilization at 134℃/18 min Stainless Steel

Page 29: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

27

All spec. in mm D : Diameter L : Total Length REF: Reference Number

Note

HT01-290001

HT01-290003

HT01-290004

D 4.0

D 5.0

D 3.5 HT01-100001

D 4.0 HT01-100002

D 4.5 HT01-100003

D 5.0 HT01-100004

D 6.0 HT01-100005

D 7.0 HT01-100006

D 3.1 HT02-080001

D 3.1 HT02-080002

D 3.1 HT02-080003

D 3.1 HT02-080004

L

11.0

9.5

8.0

D 3.4 HT02-080005

D 3.4 HT02-080006

D 3.4 HT02-080007

D 3.4 HT02-080008

L

11.0

9.5

8.0

D 3.9 HT02-080009

D 3.9 HT02-080010

D 3.9 HT02-080011

D 3.9 HT02-080012

L

11.0

9.5

8.0

D 4.4 HT02-080013

D 4.4 HT02-080014

D 4.4 HT02-080015

D 4.4 HT02-080016

L

11.0

9.5

8.0

D 5.4 HT02-080017

D 5.4 HT02-080018

D 5.4 HT02-080019

L

9.5

8.0 HT01-180003

HT01-090001

Path Pin

Guide Pin

101 Countersink Drill

Screwman Ratchet Hex Driver

Drill Extender

Final Drill

D REF

D REF

REF

REF

LD REF

REF

Page 30: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

All spec. in mm S/L : Short / Long N : NewtonREF: Reference Number

Note

28

HT01-01000110/20/30/40 N-cm

Torque Wrench

HT01-160001

Depth Gauge

HT01-150001

HT01-150002

Hex Driver

S

L

HT01-180001

HT01-180002

Ratchet Hex Driver

S

L

HT01-140001

HT01-140002

Ratchet Adapter

S

L

HT01-130001

HT01-130002

Handpiece Adapter

S

L

SHT02-300001

101 Premium Surgical Kit Case

1 Case

S/L REF

S/L REF

S/L REF

S/L REF

N REF

REF

REF

Page 31: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

All spec. in mmD : DiameterG : Gingava Height Ab.H: Abutment HieghtREF : Reference

Note

29

Try-in Kit Anodization / Color-Code Management Sterilization at 134℃/18 min

Anodization / Color-Code Management Sterilization at 134℃/18 minTry-in Kit

HT02-300005SPEC REF

25 Pcs Set

Try-in KitProduct Name Quantity

Surgical Kit Item List

Try-in Stander 128221

Try-in AngledHex DriverRatchet Hex DriverTorque Wrench

Ab.H 4.0Ab.H 2.0

G

D

Try-in Stander

D4.5

D G Ab.H REF

HT01-2005404.0/6.00.5

D4.5 HT01-2015404.0/6.01.5

D4.5 HT01-2030404.0/6.03.0

D4.5 HT01-2045404.0/6.04.5

Ab.H 4.0Ab.H 2.0

G

D

D5.5

D G Ab.H REF

HT01-2105404.0/6.00.5

D5.5 HT01-2115404.0/6.01.5

D5.5 HT01-2130404.0/6.03.0

D5.5 HT01-2145404.0/6.04.5

Ab.H 4.0Ab.H 6.0

G

D

D6.5

D G Ab.H REF

HT01-2205404.0/6.00.5

D6.5 HT01-2215404.0/6.01.5

D6.5 HT01-2230404.0/6.03.0

D6.5 HT01-2245404.0/6.04.5

Page 32: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

All spec. in mmD : Diameter G : Gingava HeightA : AngleS/L : Short / LongN : NewtonREF: Reference Number

Note

30

Try-in Angled

D4.5

D G REF

HT01-23012512.53.5

D4.5 HT01-23020020.03.5

D4.5 HT01-23027527.53.5

D4.5 HT01-23035035.03.5

G

D

D5.5

D G REF

HT01-24012512.53.5

D5.5 HT01-24020020.03.5

D5.5 HT01-24027527.53.5

D5.5 HT01-24035035.03.5

G

D

HT01-150001

HT01-150002

Hex Driver

S

L

HT01-01000110/20/30/40 N-cm

Torque Wrench

SHT02-300005

Try-in Kit Case

1 Case

HT01-180001

HT01-180002

Ratchet Hex Driver

S

L

S/L REF

S/L REF

N REF

REF

Page 33: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

All spec. in mmS/L : Short / LongN : NewtonREF: Reference Number

Note

31

Prosthetic Kit

Prosthetic Kit

HT02-300006SPEC REF

8 Pcs Set

Prosthetic Kit

HT01-150001

HT01-150002

Hex Driver

S

L

HT01-180004

HT01-180005

Handpiece Hex Driver

S

L

HT01-180001

HT01-180002

Ratchet Hex Driver

S

L

HT01-01000110/20/30/40 N-cm

Torque Wrench

HT01-180003

Screwman Ratchet Hex Driver

Product Name QuantityHex Driver 2

2211

Ratchet Hex DriverHandpiece Hex DriverScrewman Ratchet Hex DriverTorque Wrench

Surgical Kit Item List

S/L REF

S/L REF

S/L REF

REF

N REF

SHT02-3000061Case

Prosthetic KitCase REF

Sterilization at 134℃/18 min Stainless Steel

Diamond-Like Coating Color-Code Management Sterilization at 134℃/18 min Stainless Steel

Page 34: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

All spec. in mm D : Diameter REF: Reference Number

Note

32

Bone Condenser Kit

Product Name QuantityBone Condenser (Straight) 5

Product Name QuantityBone Condenser (Curved) 5

HT01-400001SPEC REF

5 Pcs Set

Bone Condenser (Straight)

HT01-400002SPEC REF

5 Pcs Set

Bone Condenser (Cur ved)

HT01-120001

HT01-120002

Bone Condenser (Straight)

D2.0

D3.5

HT01-120003D4.0

HT01-120004D4.5

HT01-120005D5.0

HT01-120008

HT01-120009

Bone Condenser (Cur ved)

D2.0

D3.5

HT01-120010D4.0

HT01-120011D4.5

HT01-120012D5.0

SHT01-400001

Bone Condenser Case

1 Case

Surgical Kit Item List

Surgical Kit Item List

Bone Condenser Kit /Straight、Cur ved

D REF D REF REF

Sterilization at 134℃/18 min Stainless Steel

Sterilization at 134℃/18 min Stainless Steel

Page 35: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

All spec. in mm D : Diameter REF: Reference Number

Note

33

HT01-020001

HT01-020002

Mucosa Punch

D3.5

D4.0

HT01-020003D4.5

HT01-020004D5.0

HT01-110001

HT01-110002

101 Tap

D3.5

D4.0

HT01-110003D4.5

HT01-110004D5.0

Others Kit

D REF D REF

Sterilization at 134℃/18 min Stainless Steel

Page 36: Product Catalog - TIONE DENTAL 101...Dental Implant Body Specimen Holder 30 TIONE Fatigue test of artificial root with a minimum diameter of Ø3.5 (Fig. 3). According to the data,

Hung Chun Bio-S Co., Ltd. Ver.1.0

www.tione-dental.com

[email protected]