prod. sheet avs venmar controls (90310)(18 02)v~specification-sh… · speed (off, min or max) or...

6
WALL CONTROLS All Venmar AVS wall controls are user-friendly. ey were created for people who want to maximise the benefits of their residential ventilation unit. With Venmar AVS wall controls, the homeowner’s specific needs are fulfilled. MAIN CONTROLS Due to the constant evolution of our technologies, it may be possible that some control functions are not compatible to some earlier unit models. For more details, please refer to the compatibility chart on last pages. X-TOUCH Part no. 40455 • 5 manual modes: RECIRC, 20MIN/H, CONT, SMART and SMART ECO; • Dehumidistat: When indoor humidity is too high and exceed the set point, unit will exchange air in high speed to take care of excess humidity. e humidity set point can be changed and you may refer to the Installation and Owner Guide; • ree defrost cycling settings: Standard, Discretion which will defrost at the speed of operation either high or low, ans Plus, which will defrost in high speed for a longer period of time for very cold climate; • Maintenance indicator; • At installation, use the X-Touch main control to perform electronic balancing, without using balancing dampers. Operation Modes MODE CONT Press the MODE key to choose the operation mode of the ventilation unit (except TURBO mode). Operating Mode will then appear on LCD screen (STANDBY, RECIRC, 20 min/h, CONT, SMART). STANDBY Put the unit on stand-by mode, so it will only respond to override wall controls (if present). On LCD screen, only the House is visible showing the control is powered on. is is the factory set default mode. RECIRC Air is recirculated inside the house on high speed. 20 min/h e ventilation unit exchanges air intermittently on a one hour cycle as follows: OFF for 40 min. (or recirculation for 40 min. on low or high speed, see Settings) and then exchange air during 20 min. on low speed. Repeat cycle aſter the 20 min. of air exchange. CONT Air is exchanged with the outdoors at the minimum blower speed. SMART Air exchange is managed according to indoor humidity measured by the wall control and outdoor temperature. In SMART mode, the SMART icon appears as well as the current operating mode called by SMART (For more details about SMART features, refer to the User Guide Main and Auxiliary wall controls available at www.venmar.ca). TURBO Press the TURBO function key to turn the unit on air exchange in high speed during 4 hours, then, the unit will get back to its previous operation mode. VC0175

Upload: doanthuan

Post on 17-Apr-2018

217 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Prod. Sheet AVS Venmar Controls (90310)(18 02)v~specification-sh… · speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user’s choice. RECIRC

WALL CONTROLS

All Venmar AVS wall controls are user-friendly. Th ey were created for people who want to maximise the benefi ts of their residential ventilation unit. With Venmar AVS wall controls, the homeowner’s specifi c needs are fulfi lled.

MAIN CONTROLSDue to the constant evolution of our technologies, it may be possible that some control functions are not compatible to some earlier unit models. For more details, please refer to the compatibility chart on last pages.

X-TOUCHPart no. 40455

• 5 manual modes: RECIRC, 20MIN/H, CONT, SMART and SMART ECO;

• Dehumidistat: When indoor humidity is too high and exceed the set point, unit will exchange air in high speed to take care of excess humidity. Th e humidity set point can be changed and you may refer to the Installation and Owner Guide;

• Th ree defrost cycling settings: Standard, Discretion which will defrost at the speed of operation either high or low, ans Plus, which will defrost in high speed for a longer period of time for very cold climate;

• Maintenance indicator;

• At installation, use the X-Touch main control to perform electronic balancing, without using balancing dampers.

Operation Modes

MODE

CONT

Press the MODE key to choose the operation mode of the ventilation unit (except TURBO mode). Operating Mode will then appear on LCD screen (STANDBY, RECIRC, 20 min/h, CONT, SMART).

STANDBYPut the unit on stand-by mode, so it will only respond to override wall controls (if present). On LCD screen, only the House is visible showing the control is powered on. Th is is the factory set default mode.

RECIRCAir is recirculated inside the house on high speed.

20 min/hTh e ventilation unit exchanges air intermittently on a one hour cycle as follows: OFF for 40 min. (or recirculation for 40 min. on low or high speed, see Settings) and then exchange air during 20 min. on low speed. Repeat cycle aft er the 20 min. of air exchange.

CONTAir is exchanged with the outdoors at the minimum blower speed.

SMARTAir exchange is managed according to indoor humidity measured by the wall control and outdoor temperature. In SMART mode, the SMART icon appears as well as the current operating mode called by SMART (For more details about SMART features, refer to the User Guide Main and Auxiliary wall controls available at www.venmar.ca).

TURBO

Press the TURBO function key to turn the unit on air exchange in high speed during 4 hours, then, the unit will get back to its previous operation mode.

VC0175

Page 2: Prod. Sheet AVS Venmar Controls (90310)(18 02)v~specification-sh… · speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user’s choice. RECIRC

VC0119

DECO-TOUCHPart no. 40400

• Allows the user to choose either the manual modes or the automatic mode (dehumidistat)• 1” x 1” LCD display• Digital display with blue backlighting• Dynamic exchange and recirculation* indicators• Interior relative humidity displayed• Maintenance indicator

Operation ModesRECIRC Mode*In this mode, the air is recirculated inside the house at high speed.

20 min/h ModeThe ventilation unit exchanges air intermittently on a one-hour cycle as follows: OFF for 40 min. (or recirculation* on high or low speed for 40 min.) and then exchanges air during 20 min. on low speed. Repeats cycle after the 20 min. of air exchange.

Min Mode

Air is exchanged with the outside on low speed.

Max Mode

Air is exchanged with the outside on high speed.

HygrometerIn the operating modes listed above, select a dehumidistat override so that if the relative humidity (RH) in the house exceeds the RH setting previously stored, the ventilation unit will exchange in high speed until the target indoor RH setting is reached.

* Recirculation is not available to all units. For more details, please refer to the compatibility chart on last pages.

VC0101

SMARTSETMODEPREF

Operation Modes SMART ModeOur latest innovation! This mode optimizes automatically the ventilation functions to ensure reaching an unsurpassed comfort in the house.

VENT ModeIn this mode, the air exchange with the outside is performed with the speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user’s choice.

RECIRC ModeIn this mode, the user decides to recirculate the air inside his house (OFF, MIN, MAX or OFF, MAX, according to the unit).

PROG ModeThe ventilation unit operation is factory set for alls 4 periods (morning, day, evening and night), for week days and week end days. However, these settings can be modified by the user to meet his own needs.

ALTITUDEPart no. 40445

• Automatic and programmable control (keeps in memory all ventilation settings even aft er a power failure)• Digital display with backlight (blue or green)• Day, hour and periods of the day displayed• Dynamic exchange and recirculation indicators, and also indoor and outdoors temperature• Maintenance indicator

MAIN CONTROLS (CONT’D)

Page 3: Prod. Sheet AVS Venmar Controls (90310)(18 02)v~specification-sh… · speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user’s choice. RECIRC

MAIN CONTROLS (CONT’D)

- -5°C23°F

5°C41°F

C OM

FOR

TZ

ON

E

-20°C-4°F

OFF MIN MAX

#XXX

XX

01/98

VC0086

CONSTRUCTO

ConstructoPart no. 40350

Th e Constructo main control adjusts the air supply speed using the sliding button: OFF, MIN (low speed air exchange) and MAX (high speed air exchange). Also, the maximum humidity level for your house is selected by the knob.

INTERMITTENT

MAXMIN

VC0124

L-T

Lite-Touch ConstructoPart no. 40370

Th e light indicator of this wall control shows clearly in wich operating mode the unit is.Th is push-button control has three functions:• Intermittent (unit is OFF during 40 minutes and then perform low speed air exchange with the outdoors during 20 minutes)• Min (low speed air exchange)• Max (high speed air exchange)NOTE: Wall control appearance may slightly vary.

RECIRCULATION

MAXMIN

VC0145

S-T

Simple-Touch ConstructoPart no. 40390

Th e light indicator of this wall control shows clearly in wich operating mode the unit is.Th is push-button control has three functions:• Recirculation (stops exchanging air with the outdoors and recirculates indoor air at high speed)• Min (low speed air exchange)• Max (high speed air exchange)NOTE: Wall control appearance may slightly vary.

Page 4: Prod. Sheet AVS Venmar Controls (90310)(18 02)v~specification-sh… · speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user’s choice. RECIRC

VC0009

DehumidistatPart no. 11297

Th e knob allows to adjust the maximum desired indoor humidity level during fall, winter and spring. Th is control is graduated in relative humidity percentage degrees. When a higher humidity level is detected, the unit turns on high speed until the situation is corrected.

AUXILIARY CONTROLS

OFF

10

TurnPast

VC0017

20

3040

50

60

MINUTES

HOLD

60-minute mechanical timerPart no. 00910

Th is timer allows for 10 to 60 minutes of high speed operation, to expel rapidly indoor stale air. Can be installed in bathrooms kitchen or laundry room.

VC0141

20-minute lighted push buttonPart no. 12030

Th is timer allows the unit to provide 20 minutes of high speed ventilation at the push of a button, to expel rapidly indoor stale air. Lighted when activated, up to fi ve of them can be installed (e.g.: in bathroom, kitchen, laundry room, etc.).NOTE: Push button appearance may slightly vary.

VC0143

20/40/60 minute push buttonPart no. 03364

Th is timer allows the unit to turn on high speed during 20, 40 or 60 minutes to expel rapidly indoor stale air. Within 2 seconds, press once for 20 minutes, twice for 40 minutes or three times for a 60-minute activation. Press another time to deactivate.NOTE: Push button appearance may slightly vary.

Page 5: Prod. Sheet AVS Venmar Controls (90310)(18 02)v~specification-sh… · speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user’s choice. RECIRC

Mod

el n

o.N

ame

X-T

ouch

M

od. n

o.

4045

5

Alti

tude

ver

sion

3.0

1M

od. n

o. 4

0440

Alti

tude

ver

sion

4.0

4 an

d up

Mod

. no.

4044

5(N

OT

E 1

)

Dec

o-To

uch

vers

ion

2.01

Mod

. no.

403

95

Dec

o-To

uch

vers

ion

2.04

Mod

. no.

404

00(N

OT

E 1

)

Lite

-Tou

ch

Con

stru

cto

Sim

ple-

Touc

h C

onst

ruct

oC

onst

ruct

o20

/40/

60

min

utes

4391

1A

VS

E15

EC

M E

RV

PJ0

514x

xxxx

xx (

NO

TE

2)

PJ0

514x

xxxx

xx (

NO

TE

2)

4390

1A

VS

E15

EC

M H

RV

PA04

14xx

xxxx

x (N

OT

E 2

)PA

0414

xxxx

xxx

(NO

TE

2)

4313

5A

VS

E15

HR

VP

C01

14xx

xxxx

x (N

OT

E 2

)P

C01

14xx

xxxx

x (N

OT

E 2

)

4112

6A

VS

E10

HR

VP

E01

14xx

xxxx

x (N

OT

E 2

)P

E01

14xx

xxxx

x (N

OT

E 2

)

X24

ER

VE

, X

24H

RV

E,

X30

ER

VE

& X

30H

RV

EX

24 E

RV

EC

M, X

24 H

RV

EC

M,

X30

ER

V E

CM

& X

30 H

RV

EC

M

4612

1 &

471

21N

ovof

it 1.

5ES

& N

ovof

it 2.

0ES

4416

2 &

441

63K

7 E

RV

Qx0

114x

xxxx

xx (

NO

TE

2)

Qx0

114x

xxxx

xx (

NO

TE

2)

4415

2 &

441

53K

8 H

RV

Qx0

114x

xxxx

xx (

NO

TE

2)

Qx0

114x

xxxx

xx (

NO

TE

2)

4450

0 &

445

02K

10 H

RV

Qx0

114x

xxxx

xx (

NO

TE

2)

Qx0

114x

xxxx

xx (

NO

TE

2)

4415

0K

7 H

RV

4611

0 &

160

1702

HR

V C

onst

ruct

o 1.

5ES

NO

TE

3N

OT

E 3

4711

0H

RV

Con

stru

cto

2.0E

SN

OT

E 3

NO

TE

3

4711

5E

RV

Con

stru

cto

2.0E

SN

OT

E 3

NO

TE

3

4672

0 &

467

25S

olo

1.5E

S

4772

0S

olo

2.0E

S

4150

2 &

415

00A

VS

Con

stru

cto

1.0

HR

Vxx

xx08

08xx

xxx

NO

TE

4B

x081

4xxx

xxxx

(N

OT

E 2

)xx

xx08

08xx

xxx

NO

TE

4B

x081

4xxx

xxxx

(N

OT

E 2

)B

x101

702x

xxxx

(NO

TE

4)

4150

6 &

415

04A

VS

Con

stru

cto

1.0

ER

Vxx

xx08

08xx

xxx

NO

TE

4B

x081

4xxx

xxxx

(N

OT

E 2

)xx

xx08

08xx

xxx

NO

TE

4B

x081

4xxx

xxxx

(N

OT

E 2

)B

x101

702x

xxxx

(NO

TE

4)

4155

4 &

415

56A

VS

C12

ER

VL

x051

702x

xxxx

(NO

TE

4)

4155

0 &

415

52A

VS

C12

HR

VL

x021

702x

xxxx

(NO

TE

4)

4170

2A

VS

S10

ER

Vpl

us

4170

6A

VS

S10

n E

RV

plus

4170

0A

VS

S10

ER

VN

OT

E 3

NO

TE

3TA

0115

xxxx

xxx

NO

TE

4

4170

4A

VS

S10

c E

RV

CR

12H

RV,

CR

12E

RV

AV

S C

R12

HR

V, A

VS

CR

12 E

RV

NO

TE

3N

OT

E 3

4170

8, 4

1709

,41

718,

417

19S

10 E

RV

EC

M, S

10 E

RV

 EC

M-R

, S

10d 

ER

V E

CM

, S10

d E

RV

 EC

M-R

NO

TE

3N

OT

E 3

X24

ER

VE

N, X

24H

RV

EN

, X

30E

RV

EN

X30

HR

VE

NX

24 E

RV

EC

M-N

, X24

HR

V E

CM

-N,

X30

ER

V E

CM

-N &

X30

HR

V E

CM

-N

WA

LL

CO

NT

RO

L C

OM

PAT

IBIL

ITY

CH

AR

T

The

Deh

umid

ista

t, 60

-min

ute

cran

k tim

er a

nd 2

0-m

inut

e pu

sh-b

utto

n tim

er a

re c

ompa

tible

with

all

units

.

Com

patib

le

Not

com

patib

le

Lette

rs a

nd

num

bers

Thi

s co

de is

the

seria

l num

ber

of th

e ve

ntila

tion

unit;

con

side

r on

ly th

e le

tters

and

nu

mbe

rs m

entio

ned,

not

the

“xxx

”. E

. g.:

AV

S E

15 E

CM

ER

V w

ith s

eria

l num

ber

PJ0

5150

0040

07 is

fully

com

patib

le w

ith

Alti

tude

ver

sion

4.0

3 an

d D

eco-

Touc

h ve

rsio

n 2.

04 (

PJ0

515

is h

ighe

r th

an P

J051

4).

Sub

ject

to c

hang

e w

ithou

t prio

r no

tice.

NO

TE

1:

Wal

l con

trol

incl

udin

g co

nfig

urab

le lo

w s

peed

rec

ircul

atio

n in

inte

rmitt

ent m

ode.

NO

TE

2:

Low

spe

ed r

ecirc

ulat

ion

in i

nter

mitt

ent

mod

e st

arts

with

thi

s un

it se

rial

num

ber.

H

owev

er, t

his

cont

rol r

emai

ns c

ompa

tible

with

uni

ts w

ith s

eria

l num

ber u

nder

this

one

.

NO

TE

3:

Rec

ircul

atio

n m

ode

is n

ot a

vaila

ble

for

this

uni

t.N

OT

E 4

: T

he c

ompa

tibili

ty s

tart

s fr

om th

at u

nit s

eria

l num

ber.

Page 6: Prod. Sheet AVS Venmar Controls (90310)(18 02)v~specification-sh… · speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user’s choice. RECIRC

WA

LL

CO

NT

RO

L C

OM

PAT

IBIL

ITY

CH

AR

T (

CO

NT’D

)T

he D

ehum

idis

tat,

60-m

inut

e cr

ank

timer

and

20-

min

ute

push

-but

ton

timer

are

com

patib

le w

ith a

ll un

its.

Sub

ject

to c

hang

e w

ithou

t prio

r no

tice.

ww

w.ve

nmar

.ca

Con

trol

sd18

0206

Resid

entia

l Pro

duct

s Gro

up, 5

50 L

emire

Blvd

., Dru

mm

ondv

ille,

Qc, C

anad

a J2

C 7W

9 - T

el.: 1

-800

-567

-385

5 Fa

x: 1-

800-

567-

1715

Mod

el n

o.N

ame

Alti

tude

ver

sion

3.0

1M

od. n

o. 4

0440

Alti

tude

ver

sion

4.0

4an

d up

Mod

. no.

40

445

(NO

TE

1)

Dec

o-To

uch

vers

ion

2.01

Mod

. no.

4039

5

Dec

o-To

uch

vers

ion

2.04

Mod

. no.

404

00(N

OT

E 1

)

Lite

-Tou

ch

Con

stru

cto

Sim

ple-

Touc

h C

onst

ruct

oC

onst

ruct

o20

/40/

60

min

utes

4391

1 &

439

10A

VS

ER

V E

KO

1.5

NO

TE

2N

OT

E 2

4390

1 &

439

00A

VS

HR

V E

KO

1.5

NO

TE

2N

OT

E 2

4313

0A

VS

Con

stru

cto

1.5V

PC

1312

11xx

xxx

NO

TE

3P

C13

1211

xxxx

x N

OT

E 3

4112

1A

VS

Nov

ofit

1.0

NO

TE

2N

OT

E 2

4312

1A

VS

Nov

ofit

1.5

4512

1A

VS

Nov

ofit

2.0

4370

0, 4

3710

, & 4

5700

AV

S D

uo 1

.4, A

VS

Duo

1.2

& A

VS

Duo

1.9

4411

2, 4

4133

Kub

ix E

RV

NO

TE

2N

OT

E 2

4410

2, 4

4103

Kub

ix H

RV

Plu

sN

OT

E 2

NO

TE

2

4415

0K

ubix

HR

V

4311

0 &

160

1602

HR

V C

onst

ruct

o 1.

5

4511

0 &

160

1612

HR

V C

onst

ruct

o 2.

0

4311

5 &

451

15E

RV

Con

stru

cto

Qua

ttro

1.5

& Q

uattr

o 2.

0

4372

0 &

467

25S

olo

1.5

4572

0 &

457

25S

olo

2.0

4155

6 &

415

54A

VS

Con

stru

cto

1.2

ER

VL

x011

4xxx

xxxx

N

OT

E 4

Lx0

114x

xxxx

xxN

OT

E 4

4340

0, 4

5400

& 4

8400

1.3

HE

, 1.8

HE

& 2

.6 H

E

4330

030

55 C

ompa

ct

4530

045

85 C

ompa

ct

4670

0 &

477

00D

uo 1

.5 &

Duo

2.0

H50

100H

& H

5010

0EH

5010

0H &

H50

100E

Gx0

314x

xxxx

(N

OT

E 4

)G

x031

4xxx

xx (

NO

TE

4)

Com

patib

le

Not

com

patib

le

Lette

rs a

nd

num

bers

Thi

s co

de is

the

seria

l num

ber

of th

e ve

ntila

tion

unit;

con

side

r on

ly th

e le

tters

and

nu

mbe

rs m

entio

ned,

not

the

“xxx

”. E

. g.:

AV

S C

onst

ruct

o 1.

2 E

RV

with

ser

ial n

umbe

r LC

0115

2444

567

is fu

lly c

ompa

tible

with

Alti

tude

ver

sion

4.0

3 an

d D

eco-

Touc

h ve

rsio

n 2.

04 (L

C01

15 is

hig

her t

han

Lx01

14).

NO

TE

1:

Wal

l con

trol

incl

udin

g co

nfig

urab

le lo

w s

peed

rec

ircul

atio

n in

inte

rmitt

ent m

ode.

NO

TE

2:

Com

patib

le b

ut lo

w s

peed

rec

ircul

atio

n in

inte

rmitt

ent m

ode

is n

ot a

vaila

ble

for

this

uni

t.

NO

TE

3:

The

com

patib

ility

sta

rts

from

that

uni

t ser

ial n

umbe

r, bu

t rec

ircul

atio

n m

ode

is n

ot a

vaila

ble

fo

r th

is u

nit.

NO

TE

4:

Low

spe

ed r

ecirc

ulat

ion

in i

nter

mitt

ent

mod

e st

arts

with

thi

s un

it se

rial

num

ber.

How

ever

,

this

con

trol

rem

ains

com

patib

le w

ith u

nits

with

ser

ial n

umbe

r un

der

this

one

.