// 2 0 1 6 P ro C l i m a teHVAC & Dehumidif ication Solutions Guide

Page 2: Proclimate solutions guide 062816

2© 2016 Hertz Equipment Rental Corporation. Trade/service marks are the property of their respective owners. All rights reserved. The contents of this publication are protected by the United States copyright law.

// Founded in 1965, Herc Rentals, formerly Hertz Equipment Rental Corporation, is one of the leading equipment rental suppliers in North America. Herc Rentals offers a broad portfolio of equipment across an extensive network of 280 company-operated branches, and recently expanded its ProSolutions™ line of products to better serve our customers.

The new ProSolutions™ business provides specialty equipment coupled with technical expertise and full service on-site support to solve our customers’ toughest challenges. Our industry-specific expertise and solutions-based services complement our expanded lineup of portable power, climate control, site protection, and pumping equipment. Our mission is to help you work more efficiently, effectively, and safely - no matter the job or the environment.

OR

ID

MT

WA

COUT

NV

CA

AZ NM

TX

IA

MO

AR

LA

MSAL

GA

FL

SC

NC

INOH

MI

PA

WVVA

ME

QC

NL

NB

NS

ON

MB

SK

ABBC

NH

MARICT

MD DE

NJ

VT

NY

TN

KY

WY

ND

SD

MN

WI

ILNE

KS

OK

HI

ProSolutionsTM LocationClassic Rentals Location

Page 3: Proclimate solutions guide 062816

3

SPOT COOLERS //

PACKAGED UNITS //

HYBRID UNITS //

INDUSTRIAL HIGH-STATIC AIR CONDITIONERS //

AIR COOLED CHILLERS //

CHILLED WATER AIR HANDLERS //

DEHUMIDIFIERS //

AIR QUALITY CONTROL //

PORTABLE GENERATORS //

ACCESSORIES //

SIZING CALCULATIONS //

GLOSSARY //

CREDIT APPLICATION //

5

6

9

10

13

14

16

19

21

22

23

24

26

CONTENTS

Page 4: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations4

Our branch locations are open Monday through Friday from 7:00 a.m. to 5:00 p.m., but knowledgeable members of the HERC ProSolutions™ team are available 24/7 assist you with quotes, reservations, rental delivery, and technical support.

// PROJECT CONSULTATION Before any equipment is recommended or specified, we will walk your site to truly understand your

project or event needs, its environment and special considerations. Walking your site along-side your

team will ensure we specify the right equipment, accessories and supporting service accessories.

// CUSTOMIZED SOLUTIONS

A member of our Herc ProSolutions™ team will design a plan specific for your needs and application.

We will review your needs, the environment and all the special considerations such as access, power,

available space, sound and emission requirements, and more. We don’t just deliver equipment; we

customize our offerings to suit the unique needs of every job and environment.

// SUPERVISED INSTALL AND REMOVAL

Once your specialty equipment order is placed and en route, our trained professionals will be on site

to make sure your equipment is set up properly and working as it should. If the parameters of the job

or tools need to change, we’ll be there to respond immediately to ensure your schedules stay on track

and all your needs are met.

// TECHNICAL SUPPORT

Throughout your project, you may find yourself in need of a specialist due to changing conditions or

scope of work. Help is a phone call away. We’ll be there for you during every phase of your project.

// 24/7

Our ProSolutions™ team is always open for business. We are fully equipped to solve your tough

challenges, and stand ready to respond to intense time constraints or challenging site conditions.

No matter what hours - day or night - we are ready to help you accomplish your mission-critical

projects. We know that our solutions offerings to you are only as good as our ability to provide highly

responsive service and support.

Page 5: Proclimate solutions guide 062816

HercRentals.com 5

• 1 – 5 ton models available• Self-contained units - easily portable via mounted casters• Attach flexible ducting to remove hot air• Built in condensate tank or optional heat pump are available• Must be vented when used indoors

Movincool // Office Pro 60Movincool // Climate Pro 12 Movincool // Climate Pro 18

MAKE MODEL COOLING CAPACITY HEATING CAPACITY VOLTAGE DIMENSIONS WEIGHT CAT-CLASS

Movincool Climate Pro 12 10,200 Btu/h 9,900 Btu/h 1 Phase, 115V 21" L x 27" W x 44" H 196 lbs. 718-1102

Movincool Climate Pro 18 14,600 Btu/h 13,700 Btu/h 1 Phase, 115V 21" L x 27" W x 49" H 214 lbs. 718-1102

Movincool Office Pro 60 60,000 Btu/h N/A 1 Phase, 230V 52" L x 30" W x 64" H 623 lbs. 718-1150

Movincool Office Pro 63 60,000 Btu/h N/A 3 Phase, 460V 52" L x 30" W x 64" H 705 lbs. 718-1155

SPOT COOLERS Spot Coolers can be used in large or small areas for all of your cooling or heating needs. These units allow you to cool or heat targeted areas - representing substantial energy savings in comparison to central air.

Applications:• Comfort cooling for workers• Thermal protection • Data centers• Closet server rooms

SPOT COOLERSSPO

T COO

LERS

Page 6: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations6

• Constructed for use in Class 1 Division 2 hazardous environments• One (1) 20” outlet & one (1) 20” inlet air duct connections• Electrical heat (9 kW)

• NEMA 7 Rated: Designed to contain an internal explosion without causing an external hazard• 2,000 CFM @ 0.6” Total Static Pressure• Hot dipped galvanized structural skid / cage for lifting and stacking • Integrated foldable casters• Single point electrical connections• Hour meter, phase protection and integrated temperature controls

• One (1) 20” outlet & one (1) 20” inlet air duct connections• Electrical heat (20 kW)• 2,000 CFM @ 0.6” Total Static Pressure• Hot dipped galvanized structural skid / cage for lifting and stacking • Integrated foldable casters• Single point electrical connections• Hour meter, phase protection and integrated temperature controls• Energy Guard applied to both evaporator and condenser coils for optimum corrosive protection

CAPS 5 TON NEMA7 // PPKH-5TD-0NN9KE-5B2-P1-G2CEUP

CAPS 5 TON GENERAL PURPOSE // PPKH-5TD-0NN20KE-5E5-P1-G2CEUP

PACKAGED UNITS General Purpose Packaged Units provide cooling, heating or dehumidification of recirculated air for both small and large applications. These units feature integrated temperature controls and convenient electrical / ductwork connections.

• Petrochemical• Food processing

• Commercial buildings• Hospitals

• Manufacturing• Data centers

• Film production• Pharmaceutical

Applications: Heating, cooling and dehumidification of recirculated air for the following markets;

PACK

AGED

UN

ITS

PACKAGED UNITS

MAKE MODEL TYPE CAPACITY HEATING CAPACITY CFM MOISTURE

REMOVAL VOLTAGE DIMENSIONS WEIGHT NEMA RATING

STATIC PRESSURE CAT-CLASS

CAPS PPKH-5TD GP Standard Package 5 Tons 20 kW 2,000 18 lbs./hr 460V 6' 6" L x 4' 4" W x 5' H 1,200 lbs. 4 0.6" @ 2,000 CFM 718-1210

CAPS PPKH-5TD XP Standard Package 5 Tons 9 kW 2,000 18 lbs./hr 460V 6' 6" L x 4' 4" W x 5' 9" H 1,400 lbs. 7 0.6" @ 2,000 CFM 718-1610

Page 7: Proclimate solutions guide 062816

HercRentals.com 7

PACKAGED UNITS

CAPS 10 TON GENERAL PURPOSE // PPKH-10TD-0NN36KE-5E5-P2-G2CEUP

CAPS 25 TON GENERAL PURPOSE // PPKH-25TD-0NN72KE-5E5-P2-G2CEUP

MAKE MODEL TYPE CAPACITY HEATING CAPACITY CFM MOISTURE

REMOVAL VOLTAGE DIMENSIONS WEIGHT NEMA RATING

STATIC PRESSURE CAT-CLASS

CAPS PPKH-10TD Standard Package 10 Tons 36 kW 4,000 32 lbs./hr 460V 8' 5" L x 6' W x 5' 1" H 2,300 lbs. 4 2.2' @ 4,000 CFM 718-1210

CAPS PPKH-25TD Standard Package 25 Tons 72 kW 10,000 82 lbs./hr 460V 12' 8" L x 8' 5" W x 5' 4" H 4,600 lbs. 4 2.7" @ 10,000 CFM 718-1610

• One (1) 20” outlet & one (1) 20” inlet air duct connections• Electrical heat (36 kW)• 4,000 CFM @ 2.2” Total Static Pressure• Hot dipped galvanized structural skid / cage for lifting and stacking • Fork truck compatible from all four (4) sides • Single point electrical connections• Hour meter, phase protection and integrated temperature controls • Energy Guard applied to both evaporator and condenser coils for optimum corrosive protection

• Two (2) 20” outlet & two (2) 20” inlet air duct connections• Electrical heat (72 kW)• 10,000 CFM @ 2.7” Total Static Pressure• Hot dipped galvanized structural skid / cage for lifting and stacking • Fork truck compatible from all four (4) sides • Single point electrical connections• Hour meter, phase protection and integrated temperature controls• Energy Guard applied to both evaporator and condenser coils for optimum corrosive protection

• Powder coated HD steel cabinet• 14” duct collars (2 supply, 2 return) removable• 18” duct collars (Condenser air IN and OUT)• 8” swivel casters with brake• Condensate P-trap• Stainless steel drip pan w/ threaded drain conn.• Four-way forklift pod

• Heavy duty steel cabinet• Grab handles (one pair)• Condenser coil guard• 14” or 16” duct collars (1 supply, 1 return)• Insulated evaporator section• Electro-mechanical thermostat• Recessed control panel

UNITED COOLAIR 12 TON AC WITH HEAT //MACH145G3AS

5 TON AC WITH HEAT PUMP //PAC5N3ASAHP

MAKE MODEL CFM COOLING CAPACITY

HEATING CAPACITY VOLTAGE STATIC

PRESSURE HEIGHT/WIDTH/LENGTH WEIGHT CAT-CLASS

United CoolAir PAC5N3ASAHP 2000 5 Ton 54,592 BTU 208/230-1-60 1.5" @ 2,000 CFM 67" x 29.5" x 54.5" 670 lbs. 718-1150

United CoolAir MACH145G3AS 4000 12 Ton 102,360 BTU 208/230-3-60 1.5" @ 4,000 CFM 78" x 34.5" x 71" 1300 lbs. 718-1302

PACKAGED

UN

ITS

Page 8: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations8

• Dual stage heating & cooling circuits with hot gas bypass• 7,800 CFM @ 1.25” total static pressure• Electrical heat (72 kW)• Double deflection supply air grille • Easy access return air filter grille • User friendly safety service access • Integrated quad box power receptacle

VERTICAL PACKAGED UNITS Vertical Packaged Units are custom temperature control equipment for temporary or permanent applications. Whether cooling a tent or a building, our systems meet the most demanding expectations in unique environments.

CAPS 20 TON VERTICAL // PPKV-20TD-0NN72KE-5E5-P2-VG2CEUP

MAKE MODEL COOLING CAPACITY

HEATING CAPACITY CFM MOISTURE

REMOVAL VOLTAGE DIMENSIONS WEIGHT NEMA RATING STATIC PRESSURE CAT-CLASS

CAPS PPKV-20TD 20 tons 72 kW 8,000 95 lbs./hr 460V 7' 7" L x 3' W x 8' H 2,600 lbs. 4 1.25" @ 8,000 CFM 718-1525

PACKAGED UNITS PA

CKAG

ED U

NIT

S

• Entertainment (TV/Movie) • Tent coolingApplications:

Page 9: Proclimate solutions guide 062816

HercRentals.com 9

HYBRID

UN

ITS

HYBRID UNITS

MAKE MODEL COOLING CAPACITY

HEATING CAPACITY CFM MOISTURE

REMOVAL VOLTAGE DIMENSIONS WEIGHT NEMA RATING STATIC PRESSURE CAT-CLASS

CAPS PPKH-40TD 40 Tons 120 kW 14,000 146 lbs./hr 460V 16' 5" L x 7' 8" W x 6' 7" H 8,300 4 4.25" @ 14,000 CFM 718-1830

CAPS PPKH-60TD 60 Tons 136 kW 20,000 189 lbs./hr 460V 20' L x 8' 5" W x 8' 5" H 10,500 4 4.25" @ 20,000 CFM 718-2030

CAPS 40 TON // PPKH-40TD-0NN120KE-5E5-P2-VG2CEUP

CAPS 60 TON // PPKH-60TD-0NN136KE-5E5-P2-VG2CEUP

HYBRID UNITS Hybrid Units provide cooling, heating, dehumidification, 100% return air or 100% outside air operations. These units feature large cooling and heating capacities and VFD speed control high-static evaporator fans. User friendly temperature controls, convenient electrical / ductwork connections that offers flexible operations for a variety of different applications.

• Cooling• Heating• Dehumidification• 100% outside• 100% return air operation• Dual R410A refrigeration circuits• 120 kW staged electric heat and DH option• 14,000 CFM @ 4.25” Total Static Pressure

1 Cooling2 Heating3 Dehumidification4 100% outside5 100% return air operation• Dual R410A refrigeration circuits with four stages of cooling• 136 kW staged electric heat and DH option• 20,000 CFM @ 4.25” Total Static Pressure

• Petrochemical• Food processing

• Commercial buildings• Hospitals

• Manufacturing• Data centers

• Film production• Pharmaceutical

Applications: Heating, cooling and dehumidification. 100% return

or 100% outside air for the following markets;

HYBRID UNITS: 1 UNIT, 5 FUNCTIONS

Page 10: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations10

INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

CAPS 20 TON NEMA4 // PPKH-20TD-0NN0NN-5E5-P2-S1CEUP

CAPS 20 TON NEMA7 // PPKH-20TD-0NN0NN-5B2-P2-S1CEUP

INDUSTRIAL HIGH-STATIC AIR CONDITIONERS Industrial High-static Air Conditioners provide cooling and dehumidification of return or outside air operations. These units feature large cooling capacity delivering large Delta T cooling and high-static evaporator fans. User friendly temperature controls, convenient electrical / ductwork connections that offers flexible operations for a variety of different applications. The unit’s construction features stainless steel cabinet, hot dipped galvanized lifting frame and corrosive protection on both the condenser and evaporator coils.

MAKE MODEL CAPACITY CFM MOISTURE REMOVAL VOLTAGE DIMENSIONS WEIGHT NEMA

RATING STATIC PRESSURE CAT-CLASS

CAPS PPKH-20TD-GP 20 Tons 2,800 126 lbs./hr 460V 8' 11" L x 6' 7" W x 7' 10" H 4,500 lbs. 4 7.0" @ 2,800 CFM 718-1500

CAPS PPKH-20TD-XP 20 Tons 2,800 126 lbs./hr 460V 8' 11" L x 6' 7" W x 7' 10" H 4,600 lbs. 7 7.0" @ 2,800 CFM 718-1505

• 40° Delta T cooling performance (95°F entering and 55°F leaving air) • High-Static Pressure – push air further without experiencing significant CFM loss

• Industrial construction• DDC controls and service friendly• Entering / leaving air temperature controls• Rental ready construction, controls, safeties and duct connections • Hot dipped galvanized skid & cage• Stainless steel cabinet construction• NEMA 7 Rated: Designed to contain an internal explosion without causing an external hazard

• Petrochemical• Food processing

• Commercial buildings• Hospitals

• Manufacturing• Data centers

• Film production• Pharmaceutical

Applications: Heating, cooling and dehumidification of

return or outside air for the following markets;

IND

UST

RIA

L H

IGH

-STA

TIC

AIR

CO

ND

ITIO

NER

S

Page 11: Proclimate solutions guide 062816

HercRentals.com 11

IND

USTRIA

L HIG

H-STATIC A

IR CON

DITIO

NERS

INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

CAPS 40 TON NEMA4 // PPKH-40TD-0NN0NN-5E5-P2-S1CEUP

CAPS 40 TON NEMA7 // PPKH-20TD-0NN0NN-5B2-P2-S1CEUP

MAKE MODEL CAPACITY CFM MOISTURE REMOVAL VOLTAGE DIMENSIONS WEIGHT NEMA

RATING STATIC PRESSURE CAT-CLASS

CAPS PPKH-40TD-GP 40 Tons 5,600 236 lbs./hr 460V 12' 9" L x 6' 8" W x 8' H 6,300 lbs. 4 5.5" @ 5,600 CFM 718-1800

CAPS PPKH-40TD-XP 40 Tons 5,600 236 lbs./hr 460V 12' 9" L x 6' 8" W x 8' H 6,600 lbs. 7 5.5" @ 5,600 CFM 718-1805

• 5,600 CFM @ 5.5” total static pressure

• 40° Delta F cooling performance (95°F entering and 55°F leaving air) • High-Static Pressure – push air further without experiencing significant CFM loss• Industrial construction• DDC controls and service friendly• Entering / leaving air temperature controls• Rental ready construction, controls, safeties and duct connections • Hot dipped galvanized skid & cage• Stainless steel cabinet construction• Overhead lifting with forklift pockets • Ducted return and supply air• 100% outside air rated at 95F DB• Low ambient control • High-static plenum fan • Two stage cooling with independent refrigerant circuits • Hot gas bypass on each circuit• Environmentally safe 410A refrigerant• Electronic temperature control • Panel mounted circuit breaker• Isolated high and low voltage control panel• Energy Guard applied to both evaporator and condenser coils for optimum corrosive protection• NEMA 7 Rated: Designed to contain an internal explosion without causing an external hazard

• Petrochemical• Food processing

• Commercial buildings• Hospitals

• Manufacturing• Data centers

• Film production• Pharmaceutical

Applications: Heating, cooling and dehumidification of

return or outside air for the following markets;

Page 12: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations12

INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

CAPS 80 TON NEMA4 // PPKH-80TD-0NN0NN-5E5-P2-S1CEUP

CAPS 80 TON NEMA7 // PPKH-80TD-0NN0NN-5B2-P2-S1CEUP

MAKE MODEL CAPACITY CFM MOISTURE REMOVAL VOLTAGE DIMENSIONS WEIGHT NEMA RATING STATIC PRESSURE CAT-CLASS

CAPS PPKH-80TD-GP 80 Tons 10,000 493 lbs./hr 460V 18' x 6' L 10" W x 8' 4" H 9,800 lbs. 4 6" @ 10,000 718-2300

CAPS PPKH-80TD-XP 80 Tons 10,000 493 lbs./hr 460V 18' x 6' L 10" W x 8' 4" H 9,800 lbs. 7 6" @ 10,000 718-2305

• 10,000 CFM @ 5.5” total static pressure

• 42° Delta cooling performance, (95°F entering and 53° leaving air)• High-Static Pressure – push air further without experiencing significant CFM loss• Industrial construction• DDC controls and service friendly• Entering / leaving air temperature controls• Rental ready construction, controls, safeties and duct connections• Hot dipped galvanized skid & cage• Stainless steel cabinet construction• Overhead lifting with forklift pockets • Ducted return and supply air• 100% outside air rated at 95°F DB• Low ambient control • High-static plenum fan • Four (4) stage cooling with two (2) independent refrigerant circuits • Hot gas bypass on each circuit• Environmentally safe 410A refrigerant• Electronic temperature control • Panel mounted circuit breaker• Isolated high and low voltage control panel• NEMA 7 Rated: Designed to contain an internal explosion without causing an external hazard

• Petrochemical• Food processing

• Commercial buildings• Hospitals

• Manufacturing• Data Centers

• Film production• Pharmaceutical

Applications: Heating, cooling and dehumidification of

return or outside air for the following markets;

IND

UST

RIA

L H

IGH

-STA

TIC

AIR

CO

ND

ITIO

NER

S

Page 13: Proclimate solutions guide 062816

HercRentals.com 13

AIR CO

OLED

CHILLERS W

ITH IN

TEGRATED

PUM

P PACKAGES

AIR COOLED CHILLERS WITH INTEGRATED PUMP PACKAGES

CAPS 100 TON CHILLER // PCHH-100TC-0NN0NN-5E5-0-PG2CEUP

CAPS 200 TON CHILLER // PCHH-200TC-0NN0NN-5E5-0-PG2CEUP

MAKE MODEL TYPE CAPACITY PUMP SIZE CAP INLET VOLTAGE DIMENSIONS WEIGHT NEMA RATING CAT-CLASS

CAPS PCHH-100TC 100 Ton Chiller 100 Tons 300 gpm 4" Dixon Quick Connect 460V 17' 1" L x 8' 4" W x 8' 6" H 11,000 lbs. 4 718-2560

CAPS PCHH-200TC 200 Ton Chiller 200 Tons 600 gpm 4" Dixon or 6" Flanged 460V 24' 4" L x 8' 4" W x 8' 6" H 20,000 lbs. 4 718-3060

AIR COOLED CHILLERS Air Cooled Chillers provide comfort and process cooling solutions for both commercial and industrial applications. These self-contained chiller / pump packages are designed and constructed for user friendly operation and provide state of the art control of your fluid cooling needs for everyday use.

• High efficiency scroll chiller with microprocessor controls• Integrated pump and hydronic specialties rated at 300 GPM@ 100 foot of head• Staged capacity with precise temperature control• ETL / UL listed• 0°F low ambient operations• 125°F high ambient operations• Shell and tube evaporator

• High efficiency screw chiller with microprocessor controls• Integrated pump and hydronic specialties rated at 600 GPM@ 100 foot of head• Staged capacity with precise temperature control• ETL / UL listed• 0°F low ambient operations• 125°F high ambient operations• Shell and tube evaporator

• Petrochemical• Food processing

• Commercial buildings• Hospitals

• Manufacturing• Data centers

• Film production• Pharmaceutical

Applications: Process & comfort fluid cooling

for the following markets;

Page 14: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations14

CHILLED WATER AIR HANDLERS // HORIZONTAL Chilled Water Air Handlers are designed to provide cooling and dehumidification using a chilled water source. These units provide both high-static air flow and large cooling capacity with an integrated variable speed drive. The industrial construction offers unit protection as well as easy mobility with forklift slots and / or certified overhead lifting points.

CHILLED WATER AIR HANDLERS

CAPS 50 TON // PAHH-50TC-0NN0NN-5E5-P2-VG2CEUP

CAPS 120 TON // PAHH-120TC-0NN0NN-5E5-P2-VG2CEUP

• 100% outside air or return air application• 6,250 CFM @ 5.0” total static pressure• VFD controlled indoor air blower• ETL listed• Supply & return air duct connections• 40° Delta (Delta variable by airflow and outside / return air application)• Two (2) 20” Supply Air Connections • Four (4) 20” Return / Outside Air Connections

• 100% outside air or return air application• 15,000 CFM @ 5.0” total static pressure• VFD controlled indoor air blower• ETL listed• Supply & return air duct connections• 40° Delta (Delta variable by airflow and outside / return air application)• Four (4) 20” Supply Air Connections • Six (6) 20” Return / Outside Air Connections

MAKE MODEL TYPE CAPACITY CFM DUCT SIZE

# OF SUPPLY DUCTS

# OF RETURN DUCTS

STATIC PRESSURE VOLTAGE DIMENSIONS WEIGHT NEMA

RATING CAT-CLASS

CAPS PAHH-50TC 50 TonAHU 50 tons 6,250 20" 2 4 5" 460V 100" L x 83" W x 59" H 3250 lbs. 4 718-1950

CAPS PAHH-120TC 120 Ton AHU 120 tons 15,000 20" 4 6 5" 460V 144" L x 101" W x 64" H 4350 lbs. 4 718-2650

• Petrochemical• Food processing

• Commercial buildings• Hospitals

• Manufacturing• Data centers

• Film production• Pharmaceutical

Applications: Cooling and dehumidification of air

for the following markets;

CHIL

LED

WAT

ER A

IR H

AN

DLE

RS

Page 15: Proclimate solutions guide 062816

HercRentals.com 15

CHILLED

WATER A

IR HA

ND

LERS

CHILLED WATER AIR HANDLERS // VERTICAL Chilled Water Air Handlers are designed to provide large volume cooling with an economical footprint and quiet sound level. Used in conjunction with a chilled water source, the units provide variable cooling capacity with an integrated variable speed drive. Designed for ultra-quick connection of ducting.

CHILLED WATER AIR HANDLERS

100 TON VERTICAL // AHU-100T

• 100 ton capacity• Perfect for tight space constraints• Ductable up to 4 supply and 6 return • Cam-lock connections feed in and out for daisy chain options • CFM up to 24,000 with VFD

MODEL TYPE CAPACITY CFM DUCT SIZE # OF SUPPLY DUCTS # OF RETURN DUCTS VOLTAGE DIMENSIONS WEIGHT CAT-CLASS

AHU-100T 100 Ton AHU 100 Tons 24,000 20" 4 6 optional 480V 96" L x 48" W x 101" H 4700 lbs. 718-2550

• Entertainment (TV/Movie) • Tent coolingApplications:

Page 16: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations16

DEHUMIDIFIERS

DESICCANT DEHUMIDIFIERS Desiccant dehumidifiers are the solution you’ll need when working on or around water-damaged buildings or large closed spaces where managing humidity is mission critical. They lower moisture in the air, and materials and surfaces of the building itself. Electric, gas and propane models are available.

MS-2400/1000 // CDH-R-126-2.0

MS-7500 Industrial Mobile // CDH-R-142RC1

MAKE MODEL TYPE REACTIVATION AIR VOLUME STATIC PRESSURE MOISTURE REMOVAL OVERALL DIMENSIONS WEIGHT CAT-CLASS

Arid Dry MS-2400/1000 Electric 2400 cfm max 2" @ 2000 cfm 159 gallons @ 80F and 60% 92" L x 35" W x 63" H 1,250 lbs. 719-1010

Arid Dry MS-7500 Tri-fuel 7500 cfm Max 5" @ 6500 cfm 577 gallons @ 80F and 60% 100" L x 50" W x 96" H 4,400 lbs. 719-1030

• 5,000 CFM up to 7,500 CFM all in one unit

• Variable-Frequency Drive for CFM control from 5,000 to 7,500 CFM• TRI Fuel-electric, gas, and propane• Extra 60 kW of electric heat built in for cold weather climates• Vertical frame options for tight spaces• Also available 2,400 CFM units

• Water damage restoration• Construction drying• Industrial condensation prevention

DEH

UM

IDIF

IERS

Applications:

Page 17: Proclimate solutions guide 062816

HercRentals.com 17

DEH

UM

IDIFIERS

DEHUMIDIFIERS

Phoenix // D385

Phoenix // 1200

• Water damage restoration• Construction drying • Industrial condensation prevention

• 385 CFM• Easy to transport and set-up• Runs off of two (2) 115 volt plugs• Operating range of -10°F to 140°F

• 900 CFM (verify) • Fits Through a standard door• 8 inch reactivation outlet• Dual 8 inch process outlets• 344 Pints (43 gal) per day @ AHAM Moisture removal• Operating range of -10°F to 140°F

MAKE MODEL TYPE REACTIVATION AIR VOLUME MOISTURE REMOVAL OVERALL DIMENSIONS WEIGHT CAT-CLASS

Phoenix D385 Electric 385 CFM 116 Pints/Day @ AHAM 24" L x 40" W x 21" H 105 lbs. 719-2060

Phoenix 1200 Electric 900 CFM 43 Gallons/Day @ AHAM 26" L x 35" W x 45" H 265 lbs. 719-2080

Applications:

Page 18: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations18

DEHUMIDIFIERSD

EHU

MID

IFIE

RS

• Groundbreaking water removal rate – 170 pints at AHAM • Automatic humidistat control• Displays inlet and outlet temperature and RH for easy monitoring• Digital control panel with plain-English system messages• Rugged Dri-Eaz rotomolded housing is easy to maintain and won't mar furnishings• If power is interrupted during operation, the unit will automatically restart when power is restored. (115V models only.)

LGR DEHUMIDIFIERS LGR Dehumidifiers remove large amounts of water and moisture to help repair water damage during flood and restoration work. They can also help prevent mold and, for commercial businesses, protect from water and moisture damage.

Dri-Eaz // 3500i

MAKE MODEL MOISTURE REMOVAL (MAX)

MOISTURE REMOVAL (AT AHAM) CFM RATING AMP RATING HEIGHT/WIDTH/LENGTH WEIGHT CAT-CLASS

Dri Eaz Revolution 10.1 Gal/Day 8 Gal/Day 121-180 6.2 13" x 18" x 22" 65 lbs. 719-2020

Dri-Eaz 7000XLi 29.3 Gal/Day 16.2 Gal/Day 325 8.3 33.5" x 20" x 20" 107lbs. 719-2040

Dri-Eaz 3500i 30 Gal/Day 21.25 Gal/Day 400 11.2 40.5" x 23" x 24" 160 lbs. 719-2060

• Restoration • Construction drying

• Best low-grain performance in its class• Delivers “Large” dehumidifier performance yet fits where others don’t • Control panel displays inlet and outlet temp and RH in real time• Secure, compact stacking – transport multiple units on a handtruck• Fastest access for cleaning and maintenance

Dri-Eaz // Revolution

• Advanced Crossflow Technology • Self-monitoring system. • Built-in humidistat and plain-English control panel messages• Sealed large-capacity pump basin • Ergonomic design. • Standard 12 in. ductable outlet

Dri-Eaz // 7000XLi

Applications:

Page 19: Proclimate solutions guide 062816

HercRentals.com 19

AIR Q

UALITY CO

NTRO

L

AIR QUALITY CONTROL

AIR MOVERS Air Movers are an important part of drying, especially in water damage restoration. By evaporating moisture from materials up into the air, when combined with dehumidifiers and other equipment, air movers contribute to the complete drying system.

MAKE MODEL CFM AMPS HEIGHT/WIDTH/LENGTH WEIGHT CAT-CLASS

Dri-Eaz Ace TurboDryer 2000 1.5 24" x 20.3" x 19" 33 lbs. 700-1140

Dri-Eaz Velo Airmover 885 1.9 9" × 18" × 24" 21 lbs. 700-1140

Dri-Eaz // Ace TurboDryer

Dri-Eaz // Velo Airmover

• Very low amp draw• Six position versatility for handling a wide range of applications• Dry structures fast with 1800 actual CFM• Turn or tilt on non-skid rubber feet to switch operating positions• Compact design that's stackable for operation and storage

• Engineered airflow. Patent pending outlet design ensures even, broad-path airflow for fast, consistent drying across surfaces• Multiple operating positions - dry floors, ceilings, walls and stairways quickly and efficiently• Low profile with great portability• Stackable for compact storage• Low amp draw. Only 1.9 amps• Daisy-chain with GFCI outlet

Page 20: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations20

AIR

QUA

LITY

CO

NTR

OL

AIR QUALITY CONTROL

AIR SCRUBBERS Air Scrubbers remove particles, gases and chemicals from the air. These portable filtration systems remove contaminants through a series of filters. These are vital on restoration jobs where mold, dust, asbestos, lead and chemical fumes become airborne during the restoration process.

Phoenix // Guardian

MAKE MODEL MAX CFM FILTRATION TYPICAL FILTRATION

ARRANGEMENTCOVERAGE @ 5 ACH

POWER REQUIREMENTS

DUCT DIAMETER

WIDTH/HEIGHT/DEPTH WEIGHT CAT-CLASS

Phoenix Guardian 1,400 3-stagePolyester/Pleated/ V-Bank HEPA

16,800 CF 110-120V / 12A 12/18" 25" x 39" x 25" 121 lbs. 700-1520

Dri-Eaz // DefendAir HEPA 500

MAKE MODEL CFM AMPS HEIGHT/WIDTH/LENGTH WEIGHT CAT-CLASS

Dri-Eaz DefendAir HEPA 500 250-500 3 24.6" × 26.2" × 18.2" 44 lbs. 700-1560

• True 1,400 CFM capacity. • Performs one clean air change of a 12 x 14 foot room in less than one minute.• High airflow and multiple ducting options allow for the combination of negative or positive air flow control of an area and containment air scrubbing at the same time. • Accepts either 18" flexduct or 12" flex-duct with the included adapter.

• Powerful fans motors maintain desired air flow and negative pressure• Easy transport and storage through compact design. • Specialty filters available for variable applications

Applications: Mold Abatement, Restoration, Construction, Renovation, and Industrial Applications

Page 21: Proclimate solutions guide 062816

HercRentals.com 21

PORTABLE GENERATORSPO

RTABLE G

ENERATO

RS

PORTABLE GENERATORS Provide reliable power solutions for temporary or emergency power requirements. We carry a diverse mix of generators ranging from 14KW to 320KW.

• Applications:• Emergency/disaster relief• Construction• Remediation/restoration

• Industrial/commercial facilities• Rock quarries• Petrochemical/refinery services • Catering/concessions

• Festivals/concerts• Film production• Air conditioning/chillersApplications:

MODEL ENGINE ENGINE MODEL

ENGINE TIER KW PRIME FUEL CONSUMPTION

(GAL/HR. @ FULL LOAD)DRY WEIGHT (LBS.)

WET WEIGHT (LBS.)

WEIGHT W/TRAILER (LBS.)

TRAILER DEMENSIONS

DCA15SPXU4F Kubota D1503 4F 14 (14.7) 1.09 1,179 1,367 2,080 100" x 57" x 22"

DCA20SPXU4F Isuzu 4LE2T 4F 20 (22) 1.62 1,797 2,138 2,544 105" x 57" x 17"

DCA25SSIU4F Isuzu 4LE2T 4F 20 (22) 1.62 1,797 2,138 2,544 105" x 57" x 17"

DCA36SPXU4F Isuzu 4LE2X 4F 36 (40) 2.93 2,488 3,087 4,143 148" x 66" x 23"

DCA40SSKU4F Kubota V2403 4F 28.8 (29.7) 2.20 2,250 2,823 3,879 148" x 66" x 23"

DCA45SSIU4F Isuzu 4LE2X 4F 36 (40) 2.93 2,337 2,976 4,023 148" x 66" x 23"

DCA70SSIU4F Isuzu 4JJ1X 4F 56 (62) 4.40 3,329 4,211 5,171 166" x 72" x 21"

DCA70SSJU4i John Deere

40458HFG92 4i 56 (62) 4.30 3,594 4,410 5,370 166" x 72" x 21"

DCA125SSIU4F Isuzu 4HK1X 4F 100 (110) 7.11 5,291 6,702 8,421 182" x 80" x 25"

DCA125SSJU4i John Deere

4045HFG93 4i 100 (110) 7.30 5,137 6,460 8,179 182" x 80" x 25"

DCA150SSJU4F John Deere

6068HFG08 4F 120 (132) 8.40 6,615 7,497 11,536 209" x 87" x 26"

DCA220SSJU4F John Deere

6068HFG09 4F 176 (194) 12.50 7,695 8,489 14,009 210" x 88" x 28"

DCA300SSJU4F John Deere

6090HFG09 4F 240 (264) 17.20 9,658 10,912 16,805 234" x 96" x 25"

DCA400SSI4F Isuzu 6WG1X 4F 320 (336) 22.50 12,280 13,184 19,949 265" x 94" x 28"

Page 22: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations22

ACCE

SSO

RIES

ACCESSORIES

WE CARRY A FULL LINE OF ACCESSORIES AND OPTIONAL ADD-ONS TO COMPLETE YOUR JOB.

Cable Kits //

Connectors, Flanges, and Diffusers //

Power Distribution //

Ceiling/Tent Transitions //

Filters //

Remotes and Thermostats //

Blower Units //

Chilled Water Hose //

Flexible Ducting //

Page 23: Proclimate solutions guide 062816

HercRentals.com 23

SIZING

CALCU

LATION

S

SIZING CALCULATIONS

// DETERMINING COOLING REQUIREMENTS:

To determine cooling capacity for a particular application, the following can be used as a rough guide:

Insulated areas: Provide 1 ton (12,000 BTU) of cooling capacity per 400 sq. ft. of surface area.

Uninsulated areas: Provide 1 ton (12,000 BTU) of cooling capacity per 100 to 200 sq. ft. of surface area.

Number of people present and the presence of equipment that generates heat will need to be taken

into consideration when determining requirements.

// WATER DAMAGE RESTORATION:

Two to three air changes per hour (ACH) are recommended for water damage restoration efforts.

1. Calculate the volume of the building in cubic feet (L x W x H).

2. Calculate the cubic square feet (CSF) for one air change (volume divided by 60).

3. Multiply the above number by two or three, depending on conditions.

// INDUSTRIAL CONDENSATION PREVENTION:

In this application, desiccant dehumidifiers should be used in combination with air conditioning units.

Dehumidifier flow should be approximately one-half of the air conditioner flow. 400 SCFM should be

used per one ton of AC capacity.

// INDUSTRIAL PREPARATION AND SURFACE COATINGS:

Temporary dehumidification of the inside of tanks that are being prepared for painting or industrial

coating eliminates the potential for condensation.

Sizing for Volume:

1. Calculate the volume of the tank in cubic feet (3.14 x Radius2 x H).

2. Calculate the SCFM for one air change (Volume divided by 60).

3. Calculate the dehumidification capacity required. (SCFM x ACH).

Sizing for Leakage:

1. Calculate the leakage in square feet from manholes and/or vents.

2. Calculate the dehumidification capacity required (leakage x 250 FPM).

The above calculations are to be used as a guide for estimation purposes only. For full sizing requirements and project consultation, call 888.777.2700 or visit your nearest ProSolutionsTM location.

Page 24: Proclimate solutions guide 062816

Call 844-892-1734 for rates and reservations24

GLO

SSA

RYGLOSSARY

ABBREVIATION SYMBOL TERM DESCRIPTION AC Ambient Air The air surrounding you. Ammeter An instrument used for measuring current.Amp A Ampere The unit of measurement for current.Amps A Amperage The amount of electric current in amperes. BTU British Thermal Unit The amount of work needed to raise the temperature of 1 pound of water by 1 degree Fahrenheit. Centrifugal Compressor Compression of air/gas through turning impellers. Compressor Pump of a refrigeration system which draws a low pressure on the cooling side of a refrigerant cycle and squeezes or compresses the gas into the high pressure or condensing side of the cycle. Condensor A component in the basic refrigeration cycle that ejects or removes heat from the system. Condensate Liquid discharged from compressor and/or air treatment equipment. CFM Cubic Feet per Minute Dehumidification The process of removing moisture from the air and materials. Delta T Change in temperature. Desiccant A substance such as silica gel or calcium oxide that is used as a drying agent. DC Direct Current Current from a power source that continually flows in the same direction. An electrical source of constant polarity. Dehumidification A device or process used to removing moisture from the air or other materials. Desiccant Dehumidifier A hygroscopic substance used as a drying agent, it absorbs water and is used to remove moisture; a drying agent. DX DX Unit Direct Expansion system. Evaporator The part of a refrigeration system in which the refrigerant absorbs heat and changes from a liquid to a gas. Generator A device that converts mechanical energy to electrical energy. GPP Grains per pound - used in dehumidification terms. Hz Hertz A unit of frequency equal to one cycle per second. IQ Instrument Quality Air Treated Compressed air from an oil-flooded compressor. After cooled, filtered air. k Kilo Metric prefix for units of measurement equal to thousands (1000 or 103). As an example: 1 kilohertz (kHz) equals 1000hz. kWh Kilowatthour Unit of energy consumption equal to 1000 watt-hours or the energy consumed at the rate to one kilowatt (kW) for a time of one hour. Generally used to specify a large energy consumption over a specific time interval. Latent Cooling The load is a measure of the amount of energy that is necessary to dehumidify the air in a building. NEMA National Electrical Manufacturers Association - sets standards to facilitate understanding between the manufacturers and the users of electrical products. Overload A load in excess of the design limit for a circuit. Parallel Circuit A circuit with two or more loads (or sources) connected such that all have the same voltage but different currents. Each load can be operated independent of the others. Parallel sources should have equal voltage ratings. Phase A time relationship between two electrical quantities. Polarity For electrical charge, the indication of a charge as either positive (+) or negative (-). Voltage at a point would be indicated as being either positive or negative with respect to some other point. For magnetic poles, the indication as either north or south. Power The rate at which energy is consumed.  In electronics it refers to the consumption of electrical energy in joules over time; measured in watts. PF Power Factor The ratio of true power to the apparent power in a circuit, especially those that are not purely resistive. It is also equal to the cosine of the phase angle for the circuit. PSI Pounds per Square Inch Unit for pressure of compressed air. Refrigerant Dehumidifier Removing moisture from the air by using the refrigeration cycle.

Page 25: Proclimate solutions guide 062816

HercRentals.com 25

GLO

SSARY

GLOSSARY

ABBREVIATION SYMBOL TERM DESCRIPTION Relative Humidity the amount of water vapor present in air expressed as a percentage of the amount needed for saturation at the same temperature. Resistance The opposition to current flow in a circuit; measured in ohms. Rotary Compressors Compression is produced by the positive action of rotating elements. SCFM Standard cubic feet per minute Standard Air Air at a temperature of 68°F, 14.70 PSI with a relative humidity of 36%. Per ASME. Static Pressure The amount of pressure a fan has to push and pull against to move air through a duct system. The resistance to airflow in a heating and cooling system’s components and duct work. Surge A very rapid increase of current or voltage. Thermistor A resistor made of semiconductor material having resistance that varies rapidly and predictably with temperature. Used as a temperature sensor, the resistance varies inversely with temperature. Therocouple A thermoelectric device used to measure temperatures accurately, consist of two dissimilar metals joined so that a potential difference is generated that is representative of the temperature of the junction. Transducer A device used to convert input energy of one form into output energy of another. Transformer A device used to transfer electric energy from one circuit to another. Generally used to convert one voltage-current relationship to another. Step-up transformer, increase the voltage while decreasing the current, and step-down transformer decrease the voltage while increasing the current. True Power The actual power consumed by a circuit; measured in watts. Two-stage Compressor Two Compression chambers with one air discharge. V Volt The unit by which an electromotive force or voltage is measured. V Voltage The force or electrical pressure that has the potential to cause electron flow in a circuit. Voltage Drop The difference in potential between two points caused by current flow through a component. Voltmeter An instrument used to measure voltage. W Watt The unit of measurement for power. One watt equals to the work done when one joule is used per second.

//2016 ProContractor ToolsSolutions Guide for

the Professional Contractor