Process Expert System 4.3Selection Guide
INTRODUCTION
PROCESS EXPERT SYSTEM KEY FEATURES
ARCHITECTURESOVERVIEW
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT
SYSTEM
SERVICE SUPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
LIST OF REFERENCES
©2017 Schneider Electric. All Rights Reserved.
Schneider Electric Industries SAS
Head Office35, rue Joseph Monier - CS 30323F92506 Rueil-Malmaison CedexFRANCEwww.schneider-electric.com
Table of Contents
Introduction 7
1.1 Description 7
1.2 Process Expert System is a key pillar of the EcoStruxure Platform 7
1.3 Process Expert System Overview 8
Process Expert System Key Features 9
2.1 Engineering 9
2.2 Operation and Maintenance 10
2.3 Process Expert System capabilities in some key numbers 12
Architectures Overview 13
3.1 System Presentation 13 3.1.1 System deployed on site 13 3.1.2 Licensing for Process Expert System infrastructure deployed on site 14 3.1.2 .1 Non-redundant Configuration: how to define the licenses to be ordered 15 3.1.2 .2 Redundant Configuration: how to define the licenses to be ordered 17 3.1.3 System deployed on site: very small "all-in-one" configuration 19 3.1.4 Engineering 20 3.1.5 Process Expert System for Educational entities 23 3.1.6 Promotion 23 3.1.7 Licensing Windows embedded in the virtual machines 24 3.1.7 .1 Installation rules for the virtual machines in a Process Expert System configuration 24 3.1.7 .2 Licensing Windows in the virtual machines 26
Process Expert System Configuration: Examples 27
4.1 Example 1 27 4.1.1 Configuration without redundancy of Operation Servers 27 4.1.2 Configuration with redundancy of Operation Servers 29 4.1.3 Installation and licensing the virtual machines 30
4.2 Example 2 31 4.2.1 Configuration without redundancy of Operation Servers 31 4.2.2 Configuration with redundancy of Operation Servers 33
4.2.3 Installation and licensing the virtual machines 34
4.3 Example 3 35 4.3.1 Large configuration with many servers and clients 35 4.3.2 Installation and licensing the virtual machines 38
4.4 Example 4 39 4.4.1 Extension of an existing application 39 4.4.2 Installation and licensing the virtual machines 41
Updating PES from V4.2 to V4.3 42
5.1 Overview 42
5.2 How to select the update part numbers? 42
List of References 43
6.1 List of References 43
Process Expert System Libraries 45
7.1 Introduction 45
7.2 Global templates libraries 46 7.2.1 Four main categories of templates 46 7.2.2 Configuration to edit and create instances of templates 49
7.3 Advanced Process Control Library 49 7.3.1 Presentation 49 7.3.2 Reference 51
7.4 Energy Management Library 51 7.4.1 Presentation 51 7.4.2 Reference 53
7.5 Mining, Metals and Minerals Library 53 7.5.1 Presentation 53 7.5.2 Reference 55
7.6 Cement Library 55 7.6.1 Presentation 55 7.6.2 Reference 56
7.7 Mining Library 56 7.7.1 Presentation 56 7.7.2 Reference 57
7.8 Liquid Food Library 57 7.8.1 Presentation 57 7.8.2 Reference 59
7.9 Water and Waste Water Library 597.9.1 Presentation 59 7.9.2 Reference 60
Table of Contents
Managing Licenses 61
8.1 Activation of a license 61
8.2 Management of licenses with the Software Licensing Portal 61
Hardware requirements to run Process Expert System 63
Service Support associated with Process Expert System 65
10.1 Introduction 65
10.2 Service Support definition 66
10.3 Contents of the Support Services 67
10.4 Support fees calculation 68
10.4.1 Table of units (quantity) for each license 69 10.4.2 List of references for Support Service 70 10.4.3 Quote the Support fees - example 70
Ordering Process Expert System 71
11.1 Software licenses 71
11.2 Ordering physical products 72
11.3 Ordering the Support for PES 72
Industrial PC for Process Expert System 73
12.1 Introduction 73
12.2 Offer description 74 12.2.1 Selection guide of Magelis Rack PC 74
Automation Platforms selection guide 75
13.1 Overview 75
13.2 Modicon M580 automation platform 75 13.2.1 General presentation 75 13.2.2 Architectures 81 13.2.2.1 Overview 81 13.2.2.2 Examples of architectures 82 13.2.2.3 I/O architectures 85 13.2.3 Modicon M580 processors 87 13.2.4 Communication, integrated ports and modules 89
13.3 Modicon Quantum automation platform 92 13.3.1 Architectures 92 13.3.2 Modicon Quantum processors 95 13.3.3 Power supply modules 97 13.3.4 Discrete I/O modules: DC inputs 99
13.3.5 Discrete I/O modules: AC inputs 101 13.3.6 Discrete I/O modules: DC and relay outputs 103 13.3.7 Discrete I/O modules: AC outputs 105 13.3.8 Analog I/O modules: Current/voltage, temperature probe, thermocouple inputs 109 13.3.9 Analog I/O modules: Current/voltage outputs, mixed I/O 111
13.3.10 Counter and special-purpose modules 113 13.3.11 Networks and buses 115 13.3.12 EtherNet/IP and Modbus/TCP: Module communication capability and performance 119
13.4 Modicon M340 automation platform 121 13.4.1 Architectures 121 13.4.2 Modicon M340 processors 123 13.4.3 Communication, integrated ports and modules 125
13.5 Modicon X80 I/O platform 129 13.5.1 Overview 129 13.5.2 Power supply modules 130 13.5.3 Product compatibility according to the network architecture 131 13.5.4 Discrete I/O modules: Input modules 135
13.5.5 Discrete I/O modules: Input modules and mixed I/O modules 137 13.5.6 Discrete I/O modules: Output modules 139 13.5.7 Analog I/O modules: Input modules 141 13.5.8 Analog I/O modules: Output modules and mixed I/O modules 143 13.5.9 HART analog I/O modules 145 13.5.10 Communication, integrated ports and modules 147
13.6 Modicon STB distributed I/O solution 149
13.7 Profibus Remote Master 150
13.8 Connection Interfaces 151 13.8.1 Modicon Telefast ABE7 pre-wired system discrete input and/or output sub-bases 151 13.8.2 Modicon Telefast ABE7 pre-wired system discrete input and output sub-bases 153 13.8.3 Modicon Telefast ABE7 pre-wired system analog and application-specific sub-bases 155
13.9 List of unsupported modules in PES architectures 157
13.9.1 M580 automation platform 157
13.9.2 Quantum automation platform 157
13.9.3 M340 automation platform 158
Table of Figures
Figure 1: Positioning of PES within the EcoStruxure architecture 8
Figure 2: The Object Model based on facets that give several point of view 9
Figure 3: Navigation using the Application Manager to speed up diagnostics 11
Figure 4: PES infrastructure deployed on site 14
Figure 5: Non-redundant configuration: PES licenses deployed on site 15
Figure 6: Redundant configuration: PES licenses deployed on site 17
Figure 7: Very small configuration: PES Mini 19
Figure 8: Examples of engineering configurations with a "Team"license 20
Figure 9: PES for Educational entities 23
Figure 10: Installation of virtual machines in PES infrastructure 25
Figure 11: Example 1 - PES configuration without redundancy of Operation Servers 28
Figure 12: Example 1 - PES configuration with redundancy of Operation Servers 29
Figure 13: Example 1 - Location of the virtual machines in PES configuration 31
Figure 14: Example 2 - PES configuration without redundancy of Operation Servers 32
Figure 15: Example 2 - PES configuration with redundancy of Operation Servers 33
Figure 16: Example 2 - Location of the virtual machines in PES configuration 35
Figure 17: Example 3 - PES large configuration with many servers and clients 36
Figure 18: Example 3 - Location of the virtual machines in PES configuration 38
Figure 19: Example 4 - PES before extension 39
Figure 20: Example 4 - PES after extension 40
Figure 21: Example 4 - Location of the virtual machines in PES configuration 41
Figure 22: PES General Purpose and Market/Application Libraries 45
Figure 23: GPL Library: signal processing / calculation 47
Table of Figures
Figure 24: GPL Library: process control 47
Figure 25: GPL Library: device control management / controller diagnostics 48
Figure 26: GPL Library: automation and generic devices 48
Figure 27: GPL Library: power and misc. devices 49
Figure 28: APC Library: example of use in a glass furnace 51
Figure 29: MM Library: route management 54
Figure 30: Mining Library: example of wet grinding mill 57
Figure 31: LFL Library: example of use (transfer in tanks) 58
Figure 32: Water Library: example of use (pumping station) 60
Figure 33: Software Licensing Portal on schneider-electric.com 62
Figure 34: Policy applicable to the software licenses 62
Figure 35: Maintenance and Support Services overview 65
Figure 36: Escalation process to manage customer requests 67
Figure 37: Access and services from the Support Portal 68
Figure 38: Ordering process for the PES licenses 71
Figure 39: The rack PC is located in the plant control room 73
Introduction
1.1 DescriptionProcess Expert System (PES) is the innovative process automation system from Schneider Electric. It brings together the best of the PLC/SCADA and DCS worlds to meet the demands of today’s production facilities while delivering on growing energy management requirements.
• PES offers integrated energy management features to deliver superior value throughout the lifecycle of a plant• PES also offered advanced process control and preventive maintenance capability to address to the growingdemandforimprovedoperationalefficiencyandsustainabilityintoday’smarket.• Thetightintegrationofthesystemensuresefficiencyfromdesignengineeringthroughtooperation– engineerscandeveloptheconfigurationfasterandmoreaccurately,operatorswillhavealldataattheir fingertipsforbetterinsightsandprocessoptimization,andmaintenanceteamscandiagnoseandsolve problems faster to reduce downtime• PEShelpsourcustomersmaketherightdecisionattherighttime,leadingtoincreaseduptimeforthe wholeplant,andamoreproductiveenterprise
1.2 Process Expert System is a key pillar of the EcoStruxure Platform
EcoStruxture Platform is Schneider Electric’s collaborative and integrated automation architecture for industrialandinfrastructureapplications.ItbringstogetherourTelemetry,PLC/SCADAandDCSofferingswithcompletelifecycleservicestohelpmakeyouroperationsmoreefficient.Frominitialdesigntomodernization,EcoStruxurePlatformtransparentlyconnectscontrol,operationandenterpriselevelsofyourbusiness.Alsocontributingtoyourenergyefficiencygoals,EcoStruxurePlatformhelpsyoumeasure,analyzeandimprovetheenergyconsumptionofyourprocesssoyoucanproduceefficientlywithminimumwaste,effortandcost.
EcoStruxurePlantisbuiltonanEthernetnetwork–it’sopenandflexiblearchitectureandnetworktopologiesoffertransparentaccesstotheinformationyouneed,fromtheplantflooruptotheenterpriselevel.Inaddition,itisakeybuildingblockofSchneiderElectric’scomprehensiveenergymanagementportfolio,EcoStruxure,andcomplementarytooursoftwaresuites.
AsoneofthethreepillarsoftheEcoStruxurePlatform,PESsharesthesekeyvalues.
Figure 1 shows an overview of an automation system. All elements that are located inside the dotted line arepartofPES.PEScoverstheneedsofanautomationsystemfromthefielddevicesallthewayuptothecontrolroom.Inaddition,PESisopensoothercomponentscanbeaddedtoti–eitherasdevices,othercontrollersorITlevelapplicationslikebatch,MES,historianorassetmanagement.
PROCESS EXPERT SYSTEM
KEY FEATURES
ARCHITECTURESOVERVIEW
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
Introduction
1.3 Process Expert System Overview
PESisbasedonthreekeyelements,allofwhicharedeliveredwithinasingleenvironmentthatintegratesallitskeyengineeringandoperationfunctionalities:
1. A system-wide, Ethernet based energy-aware architecture–transparentandstandardized Ethernettechnologyensuresconnectivity,flexibility,scalabilityandperformance
2. A powerful and scalable controller platform–PESsupportsarangeofcontrollerstomeet differentprocessneeds:thecontrollerplatformsaremodular,scalableandredundant,withtheabilityto addorremovehardwareonline.Inaddition,theysupportafullrangeofinputandoutputmodules,along withdedicatedcommunicationandfieldbusmodules,regulatorycontrol,sequencing,motorcontrol,power devices and instrumentation.
3. Integrated functionalities in a single environment–PESintegratesfunctionalitiesto efficientlymanageaprocessanditsenergyuseinasingleenvironmentforengineering,operationand maintenance.Thisincludesasingle,object-orienteddatabasetoengineerandmaintainsystemsmore quicklyandeasily,apowerfuloperationsandnavigationenvironmentforreal-timemonitoringandcontrol oftheplant,includingalarms,eventsandtrenddata,andstandardinterfaceswithhistorian,MESand other business systems for fast and easy information exchange.
Figure 1: Positioning of PES within the EcoStruxure Platform
Process Expert System Key Features
2.1 Engineering
PESimprovesefficiencythroughouttheengineeringphaseofaplant,acceleratingstart-upandminimizingprojectriskwithfivekeyfeatures:
1. Intuitive and modern user interface–PESembedsallthesoftwaretoolsneededtodesignaprocessapplication:• TheLibraryManagercontainsextensiveobjecttemplatesorganizedintolibraries• TheApplicationManagerdescribestheequivalentplanthierarchy• TheTopologyManagerdescribestheoveralltopologyofthesystem• TheProjectManagerdefinestheprojectthatrunsinthetopology
2.All-in-oneconfiguration–PESoffersanall-in-oneconfigurationfunctionality,allowingfastersystemdesignfromasinglepointofdataentry.ViatheApplicationManager,areplicationoftheapplicationcanbeseenasitisinreallife,usinganymodel,theISA88orISA95standards,oranyothermodelofchoice.Inaddition,thedesigncanbebasedonahierarchicalorganizationaccordingtotheP&IDdefinition,allowingeasierevolutionofthe installation.
3. Object model approach–anobjectiscomposedofdifferentfacetsthatcontaininternalinformationaboutthesoftwareparticipant.Thesefacetsofferdifferentpointsofviewofthesameobject.Interfacesallowconnectionsbetweenobjectinstances,enablingcollaborationbetweenthesoftwareparticipantsembeddedinPES,evenwhiletheyremainde-coupled.
Figure 2: The Object Model based on facets that give several point of view
INTRODUCTION
ARCHITECTURESOVERVIEW
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
Process Expert System Key Features
Figure 2shows(withtheexampleofapump)theconceptofobjectmodelling.Severalpointsofviewarerepresentedthroughthefacets:controlandthecommandofthepumpatthebottom,monitoringofthepumpthroughagraphicdisplayandfaceplateontop,andotherinformationsuchasalarms,datahistory,userguidesandsoon.Whenaninstanceofanobjectiscreated,allfacetsarecreatedaswell,alongwithallthelinksbetweenthosefacets.
4. Sustainable engineering–PESremainsadaptabletodifferentbusinessneedsateverystageoftheapplicationlifecycle.Theoriginaldesignoftheprocessapplicationcanbeadjustedatanytime,andthesystemwillexecutethemodificationsbypropagatingtherequiredchangesacrosstheplant.Modificationsofanobjectfacetcanbeappliedtoallobjectsortotheselectedinstancesonly.Systemlibrariessupportversioning,andthesystemalwaysverifiesanydiscrepancybetweentheobjectmodelanditsinstances.
5. Standard and reusable application data –PESincludesasetofobjectlibrariesthathelpkick-startthedesignprocess.Theready-to-uselibrariescanbemodifiedtoaddressspecificpreferences.Optionallibrariesfocusspecificallyonapplicationsfordifferentsegments,withembeddedexpertiselikeenergymanagementfunctionalitiestohelpwiththereductionofenergywasteatthesourceofoverconsumption.
2.2 Operation and Maintenance
PESprovidesaconsistentcontrolandoperationalinterfacewithareal-timeviewoftheprocess.ThesystemdeliversoperatorsallthedatatheyneedtomaketimelyandaccuratedecisionsandallthestandardDCSfunctionalitiesareavailableinthePESoperatorinterface,including:
1. Trending–trendsareaseamlesscombinationofreal-timeandhistoricaldata.Whenusersviewatrendpagetheycanmonitorthecurrentactivityasithappensandsimplyscrollbackthroughtimetoviewthetrendhistory. The distributed trending system handles a large number of variables without compromising system performanceordataintegrity.Operatorscanchoosefromaselectionofpre-configuredtrendpagesthatprovidecleardatarepresentationwithcustomizableviewsforquickandsimpletrendanalysis.
2. Advanced alarms and events–thePESalarmsystemisfastandreliable,providingdetailedinformationaboutthestatusoftheplant.Alarmsaredisplayedondedicatedalarmpages,withthemostrecentalarmsvisibleatalltimesinthealarmbanneroneverypage.Workinginconjunctionwiththecontroller,alarmsaretimestampedwithprecision.
3. From any operator station, monitor the process and identify the root cause of any disturbance–fromanyanimatedsymbolonthedisplaytheobjectfaceplatescanbedirectlyopened.Eachfaceplateprovidesthebasicobjectinformation(alsoindicatedbythestatusiconontheobject)alongwithawealthofotherdata,suchasmonitoringparameters,interlocks,alarmsandothers.Thisadvanceddiagnostic is performed through the Runtime Navigation Services.
Process Expert System Key Features
Figure 3: Navigation using the Application Manager to speed up diagnostics
INTRODUCTION
ARCHITECTURESOVERVIEW
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
Process Expert System Key Features
2.3 Process Expert System capabilities in some key numbers
PES offers the capabilitiestoengineerandmonitorprocesseshavingthefollowingcharacteristics:• Engineering from one to ten engineering stations • Designofapplicationswith20000objectinstances,withoneobjectinstancemanagingacontrolmodule
• Configureatopologywith50controllerswithlocalandremoteracks;eachcontrollercanmanagedeviceson variousnetworksandfieldbusses(EthernetModbus/TCP,ModbusSerial,Profibus)
• Monitoringoftheprocessfrom20stationnodes
Architectures Overview
3.1 System Presentation
3.1.1 System deployed on site
ThePESarchitectureisfullyflexibleanditsinfrastructurecanbedeployedononesinglemachinethathostsalltheneededfunctions,oronasetofmultiplemachines.Thischoicewillbebasedmainlyonthesizeoftheproject,itstopologyandtheexpectedperformanceoftheapplication.ThefunctionsneededtoexecuteaPESprojectare:
1. PES System Server–thisserverhoststheglobaldatabaseandcentralizesandsynchronizesalltheinformationthroughoutthesysteminfrastructure.Theengineeringsoftwaretoconfigure,monitor,diagnoseandmaintain the deployed application is also embedded on the System Server. The engineering software suites areembeddedonavirtualmachine,whichisinstalledwiththePESSystemServer.ThereisonlyoneSystemServerforanyPESconfiguration.
2. PES Engineering Clients–theseclientshousealltheeditorsthatareneededtoconfigureandbuildtheproject.Oneengineeringclientcanbelocatedonthesameworkstationasthesystemserver,oronanotherworkstation.Itispossibletodistributeseveralengineeringclientsacrossworkstations,enablingengineerstoworkconcurrentlyondifferentapplicationsorevenonthesameapplicationlocatedonthesystemserver. 3. PES Operation Servers–theseserversofferasetofservicessuchasI/Oservers,alarmsservers,trendserversandreportservers.AminimumofoneOperationServerisrequiredwhendeployingaPESconfiguration.In order to improve the scalability and the performance of PES the Operation Servers can be split into several machines that can be stand alone or redundant. Each operation server embeds a local PES Operation Client. Inaddition,itispossibletosetuparedundantconfigurationofthePESOperationServerstoensurethemonitoring of the automation system at any time.
4. PES Operation Clients–thenumberofOperationClientsneededdependsonfromwheretheControlSystemApplicationismonitored,andhowmanyclientstationsarerequired.Therearetwotypesofoperationclients–theControlClientenablesmodificationstobemadelikesetpoints;theViewOnlyclientdoesn’tallowanykindofmodificationtobemadetotherunningsystem.BoththeControlandViewOnlyClientscanbeusedremotelyasWebClients.Inaddition,eachOperatorServerembedsalocalOperationClient,whichcanrunexclusivelyontheserver.PESOperationClientsisembeddedwithtwomainfunctionalities:supervisionservices and advanced diagnostics through the Runtime Navigation Services.
AllthesemachinesareinterconnectedthroughtheEthernetNetworkarchitecture(refertothefigure 4). To getaccesstothecontrollersfromtheEngineeringClient,theclientmustbeconnectedtothecontrolnetworkorgetaccessfromthesupervisionnetworktothecontrolnetworkthrougharouter.Toavoidconnectingalltheworkstationsonthesamenetwork,whichmayaffecttheresponsetime,thechoiceofkeepingtwoseparatenetworksistaken,withroutingcapabilitiesbetweennetworks.Forthisreason,allfiguresrepresentingarchitecturesincludearouterbetweenthenetworks.
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
INTRODUCTION
Architectures Overview
Figure 4: PES infrastructure deployed on site
3.1.2 Licensing for Process Expert System infrastructure deployed on site
All the software components that are described above require licenses to run permanently on site. Theselicensesarenotsystemsizedependent.ThescalabilityoftheinfrastructureismanagedthroughtheApplication License where one Application License is required for the overall PES infrastructure deployed on site. Managementoflicensesisdonebyoneormoreafloatinglicensemanagers,whichcanbelocatedonanymachine.Inmostcases,thelicenseserverislocatedonthesameworkstationasthePESSystemServerforanonredundantconfiguration,butanalternativeistoinstallitonadedicatedmachine.InthecaseofredundantOperationServers,thelicensesandtheOperationClientlicensesmustbeinstalledontheserverstoensuretheavailabilityofoneOperationServerandOperationClientatanytime,andtoavoidasinglepointoffailure. PESusesvirtualizationtechnologiestoprovidesomeofitsfunctionsandfeatures.However,fromauserperspective,thisiscompletedtransparently.DependingonthePESinfrastructure,oneormorevirtualmachinesneedtobeinstalledwithPESsoftwarecomponents.Thelocationontheworkstationsandthelicensingofthevirtual machines are covered in a later section within this chapter.
Architectures Overview
3.1.2 .1 Non-redundant Configuration: how to define the licenses to be ordered
Figure 5: Non-redundant configuration: PES licenses deployed on site
1.OnePESServerlicenseismandatory.OnlyoneisrequiredinaPESconfiguration.Itincludestheengineeringclientlicense.Theclientcanbeinstalledonthesameworkstationorremotelyonanothermachine.Licensetobeordered:EUSBEUCZZSPEZZ SW PE ENG SINGLE LIC
2.Anoptionalextensionwithadditionalengineeringclientslicenses.Threepossibilitiesoflicenses,dependingonthenumberofseats(clients)tobeaddedintheconfiguration.Licensetobeordered:EUSCLTCZZSPEZZ SW PE ENG CLIENT SINGLE LIC EUSCLTCZZGPEZZ SW PE ENG CLIENT GROUP LIC EUSCLTCZZGPEZZSWPEENGCLIENTTEAMLIC
3. One PES Operation Server license is mandatory. Each Operation Server includes a local Operation Client license.DependingonthesystemsizeandtopologythesystemmayhavemorethanoneOperationServer.Licensetobeordered:EUSOPECZZSPEZZ SW PE OPER SERVER LIC
4. At least one PES Operation Client license is mandatory. The client embedded with the Operation Server licensecanbeused.Otherwise,addatleastonelicense,plusthenumberofotherlicensesrequiredforthe
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
INTRODUCTION
Architectures Overview
clientsinstalledthroughoutthesysteminfrastructure.Twokindsoflicensesareavailable:ControlClientorViewOnlyClient.BothcanbeusedasWebClients.ThePESOperationClientlicenseenablesthesupervisionservices and the Runtime Navigation Services.Licensestobeordered:EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC EUSVCCCZZSPEZZ SW PE VIEW CLIENT LIC
5.OneApplicationLicensemustbeorderedforthewholeconfiguration.Fivesizesareavailable,dependingontheautomationsystemsize.Thesizeisdefinedaccordingtothemaximumnumberofobjectinstancesthatcanbe included within the system.Possiblelicensestobeordered(oneofthesepossibilities):500 instances EUSAPPCZTSPEZZ SWPEAPPLLICEXTRASMALL1250 instances EUSAPPCZSSPEZZ SWPEAPPLLICSMALL3000 instances EUSAPPCZMSPEZZ SWPEAPPLLICMEDIUM7500 instances EUS APPCZLSPEZZ SW PE APPL LIC LARGE>7500 instances EUSAPPCZXSPEZZ SW PE APPL LIC EXTRA LARGE
Itispossibletoupgradetheapplicationlicenseinordertoincreasethenumberofobjectinstances.Possiblelicensestobeordered:500 to 1250 instances EUSAPPGZASPEZZSW PE UPG XS TO S APP LIC1250 to 3000 instances EUSAPPGZESPEZZSWPEUPGSTOMAPPLIC3000 to 7500 instances EUSAPPGZHSPEZZSWPEUPGMTOLAPPLIC7500 to >7500 instances EUSAPPGZKSPEZZSW PE UPG L TO XL APP LIC
Morethanonelicensemaybenecessarytoupgradetoalargersystem.Forexample:toupgradefrom500instancesto3000instances,twolicensesmustbeordered:EUSAPPGZASPEZZ SW PE UPG XS TO S APP LICEUSAPPGZESPEZZSWPEUPGSTOMAPPLIC
Architectures Overview
1.OnePESServerlicenseismandatory.OnlyoneisrequiredinaPESconfiguration.Itincludestheengineeringclientlicense.Theclientcanbeinstalledonthesameworkstationorremotelyonanothermachine.RedundancyofthePESSystemServerisnotpossibleandinthecaseofSystemServerfailure,engineeringandadvanceddiagnosticservicesinoperation(likenavigationwithinthecontrolsystem)arenotpossible,however,operationfromthesupervisionsystemwillremainavailable.Licensetobeordered:EUSBEUCZZSPEZZ SW PE ENG SINGLE LIC
2.Anoptionalextensionwithadditionalengineeringclientslicenses.Threepossibilitiesoflicenses,dependingonthenumberofseats(clients)tobeaddedintheconfiguration.Licensetobeordered:EUSCLTCZZSPEZZ SW PE ENG CLIENT SINGLE LIC EUSCLTCZZGPEZZ SW PE ENG CLIENT GROUP LIC EUSCLTCZZTPEZZSWPEENGCLIENTTEAMLIC
3. One PES Operation Server license is mandatory. Each Operation Server includes a local Operation Client license.DependingonthesizeandtopologyofthesystemitmayhavemorethanoneOperationServer.Forredundancy,thenumberofPESOperationServersmustbedoubled.Licensetobeordered:EUSOPECZZSPEZZ SW PE OPER SERVER LIC
3.1.2 .2 Redundant Configuration: how to define the licenses to be ordered
Figure 6: Redundant configuration: PES licenses deployed on site
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
INTRODUCTION
Architectures Overview
4. At least one PES Operation Client license is mandatory. The client embedded with the Operation Server licensecanbeused.Otherwise,addatleastonelicense,plusthenumberofotherlicensesrequiredforthe clients installed on the system infrastructure. All Operation Client licenses enable access to the runtime navigationservices.TomaintaincontroloftheautomationsystemwhenanOperationServerfails,itisrequiredto double the Operation Client licenses to ensure each Operation Client recovers a license from the Operation Serverthatisavailablewhentheotherfails.ForeachOperationClientlicense,itisrecommendedtoorderacorresponding Redundant Operation Client license and install them on a secondary server.Twokindsoflicensesareavailable:ControlClientorViewOnlyclient.BothcanbeusedasWebClients.Licensestobeordered:EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC EUSVCCCZZSPEZZ SW PE VIEW CLIENT LIC EUSLRCCZZSPEZZ SW PE REDUNDANT CTRL CLIENT LIC EUSVRCCZZSPEZZ SW PE REDUNDANT VIEW CLIENT LIC Note:SamepartnumbersneedtobeorderedforWebClients.ButWebClientsdon’tallowaccesstotheruntime navigation services.
5.OneApplicationlicensemustbeorderedforthewholeconfiguration.Fivesizesareavailable,dependingontheautomationsystemsize.Thesizeisdefinedaccordingtothemaximumnumberofobjectinstancesthatcanbe included within the system.Possiblelicensestobeordered(oneofthesepossibilities):500 instances EUSAPPCZTSPEZZ SWPEAPPLLICEXTRASMALL1250 instances EUSAPPCZSSPEZZ SWPEAPPLLICSMALL3000 instances EUSAPPCZMSPEZZ SWPEAPPLLICMEDIUM7500 instances EUS APPCZLSPEZZ SW PE APPL LIC LARGE>7500 instances EUSAPPCZXSPEZZ SW PE APPL LIC EXTRA LARGE
Itispossibletoupgradetheapplicationlicenseinordertoincreasethenumberofobjectinstances.Possiblelicensestobeordered:500 to 1250 instances EUSAPPGZASPEZZ SW PE UPG XS TO S APP LIC1250 to 3000 instances EUSAPPGZESPEZZ SWPEUPGSTOMAPPLIC3000 to 7500 instances EUSAPPGZHSPEZZ SWPEUPGMTOLAPPLIC7500 to >7500 instances EUSAPPGZKSPEZZ SW PE UPG L TO XL APP LIC
Morethanonelicensemaybenecessarytoupgradetoalargersystem.Forexample,toupgradefrom500instancesto3000instances,twopartsmustbeordered:EUSAPPGZASPEZZ SW PE UPG XS TO S APP LICEUSAPPGZESPEZZSWPEUPGSTOMAPPLIC
Architectures Overview
3.1.3 System deployed on site: very small "all-in-one" configuration
Forverysmallautomationsystemswhichdon’trequireredundancy,an“all-in-one”licensecalledPESMinienablesallthesoftwarecomponentstobeinstalledonasinglemachineatacosteffectiveprice.Thisalternativehassomeparameterswhichinclude:
1.Thecontrolsystemdoesn’trequiremorethan200objectinstances;howeverthesystemcanbeupgradedto500objectinstancesatamaximum
2.TheSystemServer,theOperationServerandtheOperationClientareinstalledonthesameworkstation
3.TheconfigurationcannotbeextendedtoasecondOperationServersoaredundantoperationconfigurationisnotsupportedbyPESMini
4. The number of Operation Clients can be extended with additional licenses Licensetobeordered:EUSMINCZTSPEZZ SWPEMINICONFWITH200OBJINSTLIC
ToaddOperationClients,usethefollowinglicenses:Licensestobeordered:EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC EUSVCCCZZSPEZZ SW PE VIEW CLIENT LIC
ItispossibletoupgradePESMinitoamaximumof500objectinstances.ThelimitationsmentionedaboveremainthesamewhenupgradingPESMini.Licensetobeordered:EUSMINGZASPEZZ SWPEUPGMINITO500OBJINSTLIC
Figure 7: Very small configuration: PES Mini
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
INTRODUCTION
Architectures Overview
3.1.4 Engineering
DependingonthestatusofthedesigneroftheProcessExpertSystemproject,therearefourpossibilitiesfor thelicenseoftheengineeringconfiguration:
1.WhenthePESprojectisexecutedbySchneiderElectricstaff,SchneiderElectricownsthelicenseanditisnottransferabletotheenduser.Inthiscasetherearethreepartnumbers,dependingonthenumberofusers.AMultipleUserslicense(e.g:“Group”licenseforthreeusers)includestherightstorunPESonmanycomputersthataredefinedforthislicense(e.g:runningPESonthreecomputers).Variousconfigurationsareavailabletofittheuserneeds:fromasinglesystemserverwithmanyengineeringclientstomanystandalonesystemsincluding a system server and one engineering client only. The picture below gives some examples of possible configurationswitha“Team”license(10seats).
A“Team”licenseisembeddedwith10licenserightsfortheSystemServerand10licenserightsfortheengineeringclients.Manyconfigurationscanbesetup;theruleisnottoexceedthenumberofsystemserverlicenses and the number of engineering client licenses allowed by the part number. There is a possibility to add additional Engineering clients (to be ordered separately).Thefeaturesandbenefitsofthislicenseare:
• All engineering services to design the control system (editors from Unity Pro) and the supervision (graphic builderofVijeoCitect)andthecontrollersimulatorareembedded
• Applicationlicensewithunlimitednumberofobjectinstancestodesignanysizeproject
• 1 x Operation Server (one local control client embedded)
• Possibility to run seven Control Clients/View Only clients connected to the Operation Server with access to the runtime navigation services from 4 clients.
Figure 8: Examples of engineering configurations with a "Team"license
Architectures Overview
• Runtimeservices(supervision)arelimitedtoeightcontinuoushours;andarere-launchable• Permanent licensing
Each part includes all the required services to engineer and test the design and it includes an Application licensewithanunlimitednumberofprocessobjectstoenablethedesignofanysizeofcontrolsystem.Licensestobeordered:EUSBASCZZSPEZZ SW PE ENG ASC SINGLE LIC (single user) EUSBASCZZGPEZZ SW PE ENG ASC GROUP LIC (3 users) EUSBASCZZTPEZZSWPEENGASCTEAMLIC(10users)
2.ForprojectexecutionbyaSystemIntegratorwhojoinedtheSchneiderElectricAlliancePartnerProgram,aone year license is available. This license is not transferable to the end user. The partner must have already joinedtheprogramandhecanoptionallyaccesstothePlantStuxurePESofferwithanadditionalfee.Thereisonepartnumberincludingthelicensefora“Group”ofusers(seats).EachseatincludesoneSystemServer,oneengineeringclientandanapplicationlicensewithunlimitednumberofobjectinstancestoenablethedesignanysizeofcontrolsystem.Variousconfigurationsareavailabletofittheuserneeds:fromasinglesystemserver with 3 engineering clients to 3 standalone systems including a system server and one engineering client. Thefeaturesandbenefitsofthislicenseare:
• All engineering services to design the control system (editors from Unity Pro) and the supervision (graphic builderofVijeoCitect)andthecontrollersimulatorareembedded
• Applicationlicensewithunlimitednumberofobjectinstancestodesignanysizeproject
• 1 x Operation Server (one local control client embedded)
• PossibilitytoruntwoControlClients+twoViewOnlyclientsconnectedtotheOperationServer,withruntime navigation services from any client.
• Runtimeservices(supervision)arelimitedtoeightcontinuoushours;andarere-launchable
• One year license reserved for a System Integrator who is part of the SI Alliance Partner Program This part includes all the required services to engineer and test the design. It includes an Application license withanunlimitednumberofprocessobjectstoenablethedesignofanysizecontrolsystem.Licensetobeordered:EUSBALCZZGXEZZ SW PE ENG ALL GROUP LIC (3 users)
3.ForprojectexecutionbyaSystemIntegratorwhohasnotjoinedtheSchneiderElectricAlliancePartnerProgram,theSIhasthepossibilitytoorderoneofthethreepartnumbers,dependingonthenumberofusersthatarededicatedforthisuse.AMultipleUserslicense(e.g:“Group”licenseforthreeusers)includestherightstorunPESonmanycomputersthataredefinedforthislicense(e.g:runningPESonthreecomputers).Variousconfigurationsareavailabletofittheuserneeds:fromasinglesystemserverwithmanyengineeringclientstomany standalone systems including a system server and one engineering client only. Thefeaturesandbenefitsofthislicenseare:
• All engineering services to design the control system (editors from Unity Pro) and the supervision (graphic builderofVijeoCitect)andthecontrollersimulatorareembedded
• Applicationlicensewithunlimitednumberofobjectinstancestodesignanysizeproject
• 1 x Operation Server (one local control client embedded)
• Possibility to run seven Control Clients/View Only clients connected to the Operation Server with access to the runtime navigation services from 4 clients.
• Runtimeservices(supervision)arelimitedtoeightcontinuoushours;andarere-launchable
• Permanent licensing
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
INTRODUCTION
Architectures Overview
Each part includes all the required services to engineer and test the design and it includes an Application licensewithanunlimitednumberofprocessobjectstoenablethedesignofanysizeofcontrolsystem.Licensestobeordered:EUSSISCZZSPEZZ SW PE ENG SYS INT SINGLE LIC (1 user) EUSSISCZZGPEZZ SW PE ENG SYS INT GROUP LIC (3 users) EUSSISCZZTPEZZSWPEENGSYSINTTEAMLIC(10users)
4.Forothercases,thecoreconfigurationisbasedonasectionofthePESconfigurationdescribedabove–thePESSystemServer,PESApplicationLicenseandPESOperationServerwillbeusedtodesigntheproject.Thisconfigurationistransferabletotheenduserandcanbepartofthedeployedconfigurationonsite.Thefeaturesandbenefitsofthislicenseare:
• All engineering services to design the control system (editors from Unity Pro) and the supervision (graphic builderofVijeoCitect)andthecontrollersimulatorareembedded
• MaximumnumberofobjectinstancesisdefinedbytheApplicationlicensethatisordered;therearefivesizes Licensetobeordered: EUSBEUCZZSPEZZ SW PE ENG SINGLE LICPossiblelicensestobeordered(oneofthesepossibilities):500 instances EUSAPPCZTSPEZZ SWPEAPPLLICEXTRASMALL1250 instances EUSAPPCZSSPEZZSWPEAPPLLICSMALL3000 instances EUSAPPCZMSPEZZSWPEAPPLLICMEDIUM7500 instances EUS APPCZLSPEZZ SW PE APPL LIC LARGE>7500 instances EUSAPPCZXSPEZZ SW PE APPL LIC EXTRA LARGE
Tobeabletotestthesystemdesignusingthesupervisionsystemtheconfigurationaboveneedstobeenhanced.ItispossibletorunthesupervisionsystemwithoutthePESOperationServerlicenseforonly15minutes so to obtain permanent runtime services provided by the supervision system an Operation Server license minimum must be added. This license enables a local Control Client on the server.Licensetobeordered:EUSOPECZZSPEZZ SW PE OPER SERVER LIC
Thisconfigurationcanbereusedforthedeployedconfigurationonsite.Itmaybeenhancedwithothersoftwarecomponents,dependingontheautomationsystemrequirements–refertochapter3.1.1.
PESMinicanbeusedforprojectengineeringwithinitslimitationof200objects.Licensetobeordered:EUSMINZTSPEZZ SWPEMINICONFWITH200OBJINSTLIC
ExceptforPESMini,alltheengineeringconfigurationscanbeextendedwithadditionalengineeringclientlicenses.Threepossibilitiesoflicenses,dependingonthenumberofseats(clients)tobeaddedintheconfiguration.Licensestobeordered:EUSCLTCZZSPEZZ SW PE ENG CLIENT SINGLE LIC EUSCLTCZZGPEZZ SW PE ENG CLIENT GROUP LIC EUSCLTCZZTPEZZSWPEENGCLIENTTEAMLIC
Architectures Overview
3.1.5 Process Expert System for Educational entities
This license is dedicatedtoEducationalentities(professionalschools,universities,...)tomanagecoursesforprofessorsandstudents.Theconfigurationisbasedonasingleserverandamaximumoftenengineeringclientsconnectedtothisserver.Thisconfigurationallowsthecreationofprojectswithatotalamountof3000processobjectinstances.This license cannot be sold or transferred to system integrators or end users even for training purposes.
Inaddition,thislicenseenablestheruntimeserviceswith8hoursofcontinuoususe(relaunchable)forasupervisoryconfigurationof:
• 5Operationservers
• 10 Control clients / view only clients
• Access to Runtime Navigation Services from 10 control clients maximum
Licensetobeordered:EUSBASEZMSPEZZ SW PE EDUC ENG SINGLE LIC
3.1.6 Promotion
ForpromotionofPESbySchneiderElectricstaff,ademosoftwarelicenseisavailable.Thislicenseisnottransferable to anyone outside of Schneider Electric. This license is dedicated to demonstrations and must not beusedforcustomerprojectdesign.Inadditionitfeatures:
• All engineering services to design the control system (editors from Unity Pro) and the supervision (graphic builderofVijeoCitect)andthecontrollersimulatorareembedded
Figure 9: PES for Educational entities
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
INTRODUCTION
Architectures Overview
• Applicationlicensewiththenumberofobjectinstanceslimitedto500
• 1 x Operation Server (one local control client embedded)
• PossibilitytorunsevenControlClients/View-OnlyClientsconnectedtotheOperationServerwithaccessto the runtime navigation services from 1 client
• Runtimeservices(supervision)arelimitedtoeightcontinuoushours;andarere-launchable
• Permanent license
Licensetobeordered:EUSSSVZZSPEZZ SW PE SALES LICENSE (single user)
3.1.7 Licensing Windows embedded in the virtual machines
3.1.7 .1 Installation rules for the virtual machines in a Process Expert System configuration
Each PESconfigurationembedsatleastonevirtualmachine,whichrunsthesoftwareparticipantsrequiredtodesignthecontrolsystem.Duringoperation,itenablesadvanceddiagnosticsthroughtheruntimenavigationservices.Thevariousconfigurationsthatarepossibleforadistributedsystemleadtorequireoneormorevirtualmachines:
• All-inoneconfigurationrequiresonlyonevirtualmachine.
• Distributedconfigurationsacrossseveralmachinesrequirethenumberofvirtualmachinesaccordingtothe followingrules: >EachEngineeringClientneedsavirtualmachinerunningontheworkstation >NeitherOperationServer,norOperationClientrequiresanyvirtualmachineonitsworkstation >WhenaworkstationembedsanEngineeringClientplusanOperationClient,onevirtualmachinemustbe installedontheworkstation.Thisvirtualmachineisusedforengineeringandruntimenavigationservicesfrom the local Operation Client > The runtime navigation services issued from one Operation Client uses an instance of a virtual machine whentheuserwantstoaccesstothecontrollerprogramcontextuallyon-line.ExceptforOperationClients runningonthesamemachineasanEngineeringclient,thesystemserverrequiresavirtualmachine.Only one virtual machine is installed on the system server with several instances of the virtual machine that can run in parallel. ThevirtualmachineembedsaMicrosoftWindowsoperatingsystem.Eachoperationclientthatusesthe service of an instance of the virtual machine requires a license. The number of licenses required for the virtual machine depends on the number of simultaneous access to the virtual machine from the operation clientsrunningonoperationworkstations,meaningthatseveralinstancesarerunningatthesametime.To getthesimultaneousaccessfromalltheoperationclientsatthesametime,alicensefortheVMisrequired foralltheoperationclients.Intheory,alloperationclientsmayneedanaccesstothevirtualmachineto accesstothecontrollerprogramon-line.However,onlyoneaccessfor4operationclientswillbesufficientin most applications.
The drawings in this document show the difference between the virtual machine (only one per machine) and the number of licences required to run the advanced diagnostics.
Show the virtual machine installed on the computer
Identifies a license to enable Windows operating system in the virtual machine
Architectures Overview
Figure 10 showsanexampleofthelocationofthevirtualmachinesinaPESconfiguration,accordingtotherulesdefinedabove.
Inthisexample,threeworkstationsareembeddedwithanEngineeringClient,soavirtualmachinehastobe installed on all of them and must be licensed. The system server requires a virtual machine to launch the advanced diagnostics through the runtime navigation services from the Operation Clients. One license is required as a minimum on the server to enable the navigation within the controller program from one operation client.Inthecaseofmultipleclientsaccessingacontroller,additionallicensesaccordingtothenumberofsimultaneousaccessmustbeadded(maximumsixinthatcase,consideringthateachOperationServerisembedded with an Operation Client and the Operation Client installed on the same machine as the Engineering Clientusesthelocalvirtualmachine).Inanominalusageofthisconfiguration,twolicensesforthevirtualmachinewillbesufficientforthesixoperationclients.
Figure 10: Installation of virtual machines in PES infrastructure
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
INTRODUCTION
Architectures Overview
3.1.7 .2 Licensing Windows in the virtual machines
EachvirtualmachineisembeddedwithMicrosoftWindows7Proastheoperatingsystem.Eachvirtualmachinerequires a license. A trial period without a license is available. Tocoverthelicensingofvirtualmachine,Microsoftrecommendssubscribingthe“SoftwareAssurance”,withWindowsProassoftwareincludedinthecontract.Theuserhastoorderthenumberof“CALVDA”thatisrequiredforhisconfiguration.SoftwareAssuranceincludesthemaintenanceservice.Thissolutiongenerallysuitsmedium/largecompaniesthathavealreadycontractedwithMicrosoftforvarioussoftwareandthelicensesrequiredfortheVMscanbeaddedintheirvolumecontract.
MicrosoftproposesanalternativetosubscribetoacontractcalledMPSA(MicrosoftProductsandServicesAgreement),whichenablessubscriptiontoforasetof“CALVDA”forWindowsPro.
Process Expert System Configuration: Examples
Throughfourexamples,thischapterprovidestheinformationtodefineaPESconfigurationintermsoftopologyandliststherequiredpartnumbersthatneedtobeordered.Foreachconfiguration,thelocationofthevirtualmachines is described. Also the associated number of Windows licences for the virtual machines is mentioned.Note:Foroneexample,manyotherconfigurationsarepossibletolocatethesoftwarepiecesandthesoftwarelicenses.Thelocationoflicensesisguidedbythreemainrules:
1. All software licenses related to engineering are stored on the system server
2.Toavoidasinglepointoffailure,softwarelicensesforoperation(serverandclients)arelocatedononeoperationserver,whichisonanothermachinethanthesystemserver.
3.Incaseofredundantconfigurationforsupervision,thelicensesaredistributedinordertoensuretheavailability of the primary or secondary server(s) and client(s) at any time.
4.1 Example 1
4.1.1 Configuration without redundancy of Operation Servers
This example is an automation system with
• 400objectinstances
• Adedicatedstationforthesystemserverandaremoteengineeringclientonanotherworkstation
• TwoworkstationssetupasOperationClientstomonitortheprocess
• Oneservertocollectprocessdata;withthesamemachineusedasanOperationClient
• No supervision redundancy
Fourworkstationsareusedinthisconfiguration
• Workstation1–dedicatedforthePESSystemServer
• Workstation2–dedicatedforoperationsandembedstheserverandoneOperationClient
• Workstation3–dedicatedasanoperatorworkstationasitembedsoneOperationClient
• Workstation4–dedicatedasanoperatorworkstationasitembedsoneOperationClient
• Workstation5–dedicatedasanEngineeringClientthatwillbeusedformaintenanceoftheautomationsystem
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
Process Expert System Configuration: Examples
Figure 11: Example 1 - PES configuration without redundancy of Operation Servers
Licenses installedontheworkstations• Workstation11 x EUSBEUCZZSPEZZ SW PE ENG SINGLE LIC1 x EUSAPPCZTSPEZZ SWPEAPPLLICEXTRASMALL(500objectinstances)
• Workstation21 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (embeds one client)2 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation3Nolicenseinstalled;theOperationClientgetsitslicensefromtheOperationServer
• Workstation4Nolicenseinstalled;theOperationClientgetsitslicensefromtheOperationServer
• Workstation5 Nolicenseinstalled;theEngineeringClientgetsitslicensefromtheSystemServer
Note:iftheOperationClientmustbelocatedonanothermachinethanthemachinehostingtheOperationServer,anotherOperationClientlicensemustbeorderedandinthiscasethisadditionallicenseshouldbeinstalledonWorkstation2.
Process Expert System Configuration: Examples
4.1.2 Configuration with redundancy of Operation Servers
This example is an automation system with
• 400objectinstances
• Adedicatedstationforthesystemserverandaremoteengineeringclientonanotherworkstation
• TwoworkstationssetupasOperationClientstomonitortheprocess
• Oneserverwithredundancytocollectprocessdata;withthesamemachineusedasanOperationClient
Fiveworkstationsareusedinthisconfiguration
• Workstation1–dedicatedforthePESSystemServer
• Workstation2–dedicatedforoperationsasitembedstheprimaryserverandoneOperationClient
• Workstation3–dedicatedforoperationsasitembedsthesecondaryserverandoneOperationClient
• Workstation4–dedicatedasanoperatorworkstationasitembedsoneOperationClient
• Workstation5–dedicatedasanoperatorworkstationasitembedsoneOperationClient
• Workstation6–dedicatedasanEngineeringClientthatwillbeusedformaintenanceoftheautomationsystem
Figure 12: Example 1 - PES configuration with redundancy of Operation Servers
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
Process Expert System Configuration: Examples
Licensesinstalledontheworkstations
• Workstation11 x EUSBEUCZZSPEZZ SW PE ENG SINGLE LIC1 x EUSAPPCZTSPEZZ SWPEAPPLLICEXTRASMALL(500objectinstances)
• Workstation2:1 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (primary server with client)2 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation31 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (secondary server with client)2 x EUSLRCCZZSPEZZ SW PE REDUNDANT CTRL CLIENT LIC
• Workstation4Nolicenseinstalled;theOperationClientgetsitslicensefromtheOperationServersonworkstations2or3(Primary or Secondary)
• Workstation5Nolicenseinstalled;theOperationClientgetsitslicensefromtheOperationServersonworkstations2or3(Primary or Secondary)
• Workstation6Nolicenseinstalled;theEngineeringClientgetsitslicensefromtheSystemServer
Note:iftheconfigurationrequiresOperationClientsinsteadoftheOperationClientsontheOperationServer,then four additional Operation Client licenses must be ordered. They must be distributed on the primary and the secondaryOperationServers:2 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC2 x EUSLRCCZZSPEZZ SW PE REDUNDANT CTRL CLIENT LIC
2 x EUSLCCCZZSPEZZmustbeinstalledonWorkstation2and2xEUSLRCCZZSPEZZmustbeinstalledonWorkstation3.
4.1.3 Installation and licensing the virtual machines
Asvirtualmachinesarenotinstalledeitheronoperationserversoroperationclients,thelocationofthevirtualmachines is the same in both cases. Twovirtualmachinesarerequiredforthisconfiguration:• x1ontheworkstationembeddingtheEngineeringClient• x1 on the System Server Minimumtwolicenses(CALVDA)arerequiredtoenableWindowstobeembeddedinthevirtualmachines,which can be extended with two other rights for the system server that will enable 3 concurrent accesses to the virtual machine for runtime navigation services.
Process Expert System Configuration: Examples
Figure 13: Example 1 - Location of the virtual machines in PES configuration
4.2 Example 2
4.2.1 Configuration without redundancy of Operation Servers
This example is an automation system with
• 1000objectinstances
• Two distributed areas with access for two operators only in each area
• Eacharearequiresalocalengineeringclienttomaintaintheprocess.Oneworkstationineachareaisshared for engineering and operation.
• Monitoringfromfourlocations
• TwoworkstationssetupasOperationClientstomonitortheprocess
• Twoserverstocollectprocessdata;witheachmachineusedasanOperationClient
• No supervision redundancy
Fiveworkstationsareusedinthisconfiguration
• Workstation1–dedicatedasaPESSystemServer
• Workstation2–dedicatedforoperationsasitembedsServer_1andoneOperationClient
• Workstation3–dedicatedforoperationsasitembedsServer_2andoneOperationClient
• Workstation4–dedicatedasanengineeringandoperatorworkstationasitembedsoneEngineeringClient and one Operation Client
• Workstation5–dedicatedasanengineeringandoperatorworkstationasitembedsoneEngineeringClient and one Operation Client
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
Process Expert System Configuration: Examples
Licensesinstalledontheworkstations• Workstation11 x EUSBEUCZZSPEZZ SW PE ENG SINGLE LIC1 x EUSAPPCZSSPEZZ SWPEAPPLLICSMALL(1250objectinstances)1 x EUSCLTCZZSPEZZ SW PE ENG CLIENT SINGLE LIC
• Workstation21 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (each embeds one client)1 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation31 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (each embeds one client)
1 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation4NolicenseinstalledastheEngineeringclientgetitslicensefromthesystemserveronWorkstation1andtheOperationClientgetsitslicensefromtheOperationServeronworkstation2
• Workstation5NolicenseinstalledastheEngineeringclientgetitslicensefromthesystemserveronWorkstation1andtheOperationClientgetsitslicensefromtheOperationServeronworkstation3.
Note:iftheconfigurationrequiresremoteOperationClientsinsteadofthelocalOperationClientsontheOperationServers,twootherOperationClientlicensesmustbeorderedandinthiscasethisadditionallicenseshouldbeinstalledonWorkstation2andWorkstation3.
Figure 14: Example 2 - PES configuration without redundancy of Operation Servers
Process Expert System Configuration: Examples
4.2.2 Configuration with redundancy of Operation Servers
Thisexampleisanautomationsystemwith:
• 1000objectinstances
• Two distributed areas with access for two operators only in each area
• Eacharearequiresalocalengineeringclienttomaintaintheprocess.Oneworkstationineachareaisshared for engineering and operation.
• Monitoringfromfourlocations
• TwoworkstationssetupasOperationClientstomonitortheprocess
• Redundancy of the supervision
• Tworedundantserverstocollectprocessdata;eachusedasanOperationClient
Sevenworkstationsareusedinthisconfiguration
• Workstation1–dedicatedforthePESSystemServer
• Workstation2–dedicatedforoperationsasitembedsPrimaryServer_1andoneOperationClient
• Workstation3–dedicatedforoperationsasitembedsPrimaryServer_2andoneOperationClient
• Workstation4–dedicatedforoperationsasitembedsSecondaryServer_1andoneclient
• Workstation5–dedicatedforoperationsasitembedsSecondaryServer_2andoneclient
• Workstation6–dedicatedasengineeringandanoperatorworkstationasitembedsoneEngineeringClient and one Operation Client
• Workstation7–dedicatedasengineeringandanoperatorworkstationasitembedsoneEngineeringClient and one Operation Client
Figure 15: Example 2 - PES configuration with redundancy of Operation Servers
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
Process Expert System Configuration: Examples
Licensesinstalledontheworkstations
• Workstation11 x EUSBEUCZZSPEZZ SW PE ENG SINGLE LIC1 x EUSAPPCZSSPEZZSWPEAPPLLICSMALL(1250objectinstances)1x EUSCLTCZZSPEZZ SW PE ENG CLIENT SINGLE LIC
• Workstation21 x EUSOPECZZSPEZZSWPEOPERSERVERLIC(primaryserver_1withclient)1 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation31 x EUSOPECZZSPEZZSWPEOPERSERVERLIC(primaryserver_2withclient)1 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation41 x EUSOPECZZSPEZZ SWPEOPERSERVERLIC(secondaryserver_1withclient)1 x EUSLRCCZZSPEZZ SW PE REDUNDANT CTRL CLIENT LIC
• Workstation51 x EUSOPECZZSPEZZSWPEOPERSERVERLIC(secondaryserver_2withclient)1 x EUSLRCCZZSPEZZ SW PE REDUNDANT CTRL CLIENT LIC
• Workstation6NolicenseinstalledastheEngineeringclientgetitslicensefromthesystemserveronWorkstation1andtheOperationClientgetsitslicensefromtheOperationServersonworkstations2or4.
• Workstation7NolicenseinstalledastheEngineeringclientgetitslicensefromthesystemserveronWorkstation1andtheOperationClientgetsitslicensefromtheOperationServersonworkstations3or5.
Note:iftheconfigurationrequiresremoteOperationClientsinsteadofthelocalOperationClientsontheOperationservers,thenfouradditionalOperationClientlicensesmustbeordered.TheymustbeinstalledontheprimaryserversonWorkstations2&3andtheredundantlicensesonWorkstations4&5.2 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC2 x EUSLRCCZZSPEZZ SW PE REDUNDANT CTRL CLIENT LIC
4.2.3 Installation and licensing the virtual machines
AsvirtualmachinesarenotinstalledeitheronOperationServersoronOperationClients,thelocationofthevirtual machines is the same in both cases. Threevirtualmachinesarerequiredforthisconfiguration:• x2ontheworkstationembeddinganEngineeringClient+anOperationClient• x1 on the System ServerMinimumthreelicenses(CALVDA)arerequiredtoenableWindowstobeembeddedinthevirtualmachines,which can be extended with another right for the System Server to enable up to open 4 concurrent access to the virtualmachine(WhenanOperationClientisinstalledwithanEngineeringclient,thelocalVMisusedfortheruntime navigation services).
Process Expert System Configuration: Examples
Figure 16: Example 2 - Location of the virtual machines in PES configuration
4.3 Example 3
4.3.1 Large configuration with many servers and clients
This example is an automation system distributed in 3 areas with
• 4000objectinstances
• Maintenanceoftheautomationsystemispossiblefromthe3areas.Tooptimizethenumberofworkstations, two Engineering clients are grouped with two Operation Clients and the last one is located on the system server.
• Monitoringoftheprocessfrom11workstationsdistributedinthe3areas
• FiveworkstationssetupasOperationClientstomonitortheprocessinthecontrolroom;twoofthemarealso embedded with an Engineering client.
• TwoadditionalworkstationswhichareremoteandusedasWebClients,withViewOnlyfeatures
• Fourserverstocollectprocessdata;witheachmachineusedasanOperationClient
• No redundancy of the Operation Servers
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
Process Expert System Configuration: Examples
Twelveworkstationsareusedinthisconfiguration
• Workstation1–dedicatedasthePESSystemServerandEngineeringclientandwillbeusedfor maintenance of the automation system
• Workstation2–dedicatedforoperationsasitisembeddedwithServer_1andoneclient
• Workstation3–dedicatedforoperationsasitisembeddedwithServer_2andoneclient
• Workstation4–dedicatedforoperationsasitisembeddedwithServer_3andoneclient
• Workstation5–dedicatedforoperationsasitisembeddedwithServer_4andoneclient
• Workstation6–dedicatedasanoperatorworkstationinarea1asitisembeddedwithoneOperationClient
• Workstation7–dedicatedasanoperatorworkstationinarea1asitisembeddedwithoneOperationClient
• Workstation8–dedicatedasanoperatorworkstationinarea2asitisembeddedwithoneOperationClient
• Workstation9–dedicatedasanengineeringandoperatorworkstationinarea2asitisembeddedwithone Engineering Client and one Operation Client
• Workstation10–dedicatedasanengineeringandoperatorworkstationinarea3asitisembeddedwithone Engineering Client and one Operation Client
• Workstation11–dedicatedasaremoteoperatorworkstationasitisembeddedwithoneOperationClient (View Only)
• Workstation12–dedicatedasaremoteoperatorworkstationasitisembeddedwithoneOperationClient (View Only)
Figure 17: Example 3 - PES large configuration with many servers and clients
Process Expert System Configuration: Examples
Licensesinstalledontheworkstations
• Workstation11 x EUSBEUCZZSPEZZ SW PE ENG SINGLE LIC1 x EUSAPPCZLSPEZZ SWPEAPPLLICLARGE(7500objectinstances)2 x EUSCLTCZZSPEZZ SW PE ENG CLIENT SINGLE LIC
• Workstation21 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (embeds one client)2 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation31 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (embeds one client)1 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation41 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (embeds one client)1 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation51 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (embeds one client)1 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation6Nolicenseinstalled;theOperationClientgetsitslicensefromtheOperationServeronworkstation2
• Workstation7Nolicenseinstalled;theOperationClientgetsitslicensefromtheOperationServeronworkstation2
• Workstation8Nolicenseinstalled;theOperationClientgetsitslicensefromtheOperationServeronworkstation3
• Workstation9Nolicenseinstalled;theEngineeringclientgetitslicensefromthesystemserveronWorkstation1andtheOperationClientgetsitslicensefromtheOperationServeronworkstation4
• Workstation10Nolicenseinstalled;theEngineeringclientgetitslicensefromthesystemserveronWorkstation1andtheOperationClientgetsitslicensefromtheOperationServeronworkstation5
• Workstation111 x EUSVCCCZZSPEZZ SW PE VIEW CLIENT LIC
• Workstation121 x EUSVCCCZZSPEZZ SW PE VIEW CLIENT LIC
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
Process Expert System Configuration: Examples
Figure 18: Example 3 - Location of the virtual machines in PES configuration
4.3.2 Installation and licensing the virtual machines
Threevirtualmachinesarerequiredforthisconfiguration:• x1onthesystemserver,tobeusedfromthelocalengineeringClient• x2ontheworkstationembeddinganEngineeringClient+anOperationClient
Minimumthreelicenses(CALVDA)arerequiredtoenableWindowstobeembeddedinthevirtualmachines,whichcanbeextendedwithfiveotherrightsfortheSystemServertoenableuptoopen4concurrentaccesstothevirtualmachine(whenanOperationclientisinstalledwithanEngineeringclient,thelocalVMisusedfortheruntime navigation services).
Process Expert System Configuration: Examples
Figure 19: Example 4 - PES before extension
4.4 Example 4
4.4.1 Extension of an existing application
In thisexampleaPESconfigurationhasalreadybeendeployedonsite.Theparametersofthisexampleautomationsystemare:
• 1000objectinstances
• One area with access for two operators only in this area
• Thearearequiresalocalengineeringclienttomaintaintheprocess.Oneworkstationissharedfor engineering and operation
• OneworkstationinstalledasanOperationServertocollectprocessdata;andalsousedasanOperation Client
The following list of licenses has been deployed on site• Workstation11 x EUSBEUCZZSPEZZ SW PE ENG SINGLE LIC1 x EUSAPPCZSSPEZZ SWPEAPPLLICSMALL(1250objectinstances)1 x EUSCLTCZZSPEZZ SW PE ENG CLIENT SINGLE LIC
• Workstation21 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (embeds one client)1 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation3Nolicenseinstalled;theEngineeringClientgetitslicensefromthesystemserveronWorkstation1andtheOperationClientgetsitslicensefromtheOperationServeronworkstation2
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
Process Expert System Configuration: Examples
ThePlantManagernowneedstoextendtheautomationsystemintoanotherarea,whichleadstotheadditionofmanyobjectinstancesandalsoanOperationClientinthecontrolroomtocontrolthisnewarea.Inaddition,it must be possible to maintain the automation system through an engineering client from this area. The number ofobjectinstancesisnow1500.
Toachievethisupgradetherearethreeadditionallicensesneeded:1 x EUSAPPGZESPEZZSWPEUPGSTOMAPPLIC(toupgradefrom1250to3000objectinstances)1 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC1 x EUSCLTCZZSPEZZ SW PE ENG CLIENT SINGLE LIC
Note:UpgradingtheapplicationlicensewillmeanthisexamplenowhastheequivalentoftheMediumApplication license. To enable this upgrade the user has to return the Small Application license and upgrade it to theMediumApplicationlicenseusingtheSoftwareLicensingWebPortal.
These licenses are deployed on site as follows
• Workstation1
1 x EUSBEUCZZSPEZZ SW PE ENG SINGLE LIC1 x EUSAPPCZSMPEZZ SWPEAPPLLICMEDIUM(3000objectinstances)1 x EUSCLTCZZSPEZZ SW PE ENG CLIENT SINGLE LIC• Workstation21 x EUSOPECZZSPEZZ SW PE OPER SERVER LIC (embeds one client)2 x EUSLCCCZZSPEZZ SW PE CTRL CLIENT LIC
• Workstation3Nolicenseinstalled;theEngineeringClientgetitslicensefromthesystemserveronWorkstation1andtheOperationClientgetsitslicensefromtheOperationServeronworkstation2
• Workstation4Nolicenseinstalled;theEngineeringClientgetitslicensefromthesystemserveronWorkstation1andtheOperationClientgetsitslicensefromtheOperationServeronworkstation2
Figure 20: Example 4 - PES after extension
Process Expert System Configuration: Examples
4.4.2 Installation and licensing the virtual machines
Beforetheextension,twovirtualmachineswererequiredforthisconfiguration:• x1ontheSystemServer,tobeusedfromthelocalEngineeringClient• x1ontheworkstation3embeddinganEngineeringClient+anOperationClientTwo licenses (CAL VDA) are required to enable Windows to be embedded in the virtual machines.
Aftertheextension,threevirtualmachinesarerequiredforthisconfiguration.Tobeadded:• x1ontheworkstation4embeddingtheadditionalEngineeringClient+anOperationClientThree licenses (CAL VDA) in total are required to enable Windows to be embedded in the virtual machines.
Figure 21: Example 4 - Location of the virtual machines in PES configuration
INTRODUCTION
ARCHITECTURESOVERVIEW
TABLE OF CONTENTS
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
Updating PES from V4.2 to V4.3
5.1 Overview
PES version V4.3 requires an update of the licenses that are installed on site to run this new version. Two possibilitiesareofferedtogetthelicenseupdates:1.TheCustomerhascontractedaservice,whichincludessoftwareupdate(GoldorGoldPlusservice).Inthatcase,hecanupdatethelicensesthatareattachedtothisservicecontractwithoutadditionalfee.Hecanproceed through the license generator that is hosted in the PES Support Web portal. Refer to the corresponding chapter for details about the service offer. 2.TheCustomerhasnotcontractedaservicethatincludesupdates(Silverservice),orhedidn’tcontractanyservice. A set of part numbers enables him to update each license installed on site. All licenses must be updated onaPESconfiguration.
5.2 How to select the update part numbers?
Thetablebelowgivesthecorrespondencebetweenthepartforlicensesandthepartfortheupdates:
License V4.2 Update to V4.3 to be ordered
EUSMINCZTSPEZZ
EUSMINCZTSPEZZ +
EUSMINGZASPEZZ
EUSBEUCZZSPEZZ
EUSCLTCZZSPEZZ
EUSCLTCZZGPEZZ
EUSCLTCZZTPEZZ
EUSAPPCZTSPEZZ
EUSAPPCZSSPEZZ
EUSAPPCZMSPEZZ
EUSAPPCZLSPEZZ
EUSAPPCZXSPEZZ
EUSOPECZZSPEZZ
EUSLCCCZZSPEZZ
EUSLRCCZZSPEZZ
EUSVCCCZZSPEZZ
EUSVRCCZZSPEZZ
EUSSISCZZSPEZZ
EUSSISCZZGPEZZ
EUSSISCZZTPEZZ
EUSMINDZTSPEZZ
EUSMINDZSSPEZZ
EUSBEUDZZSPEZZ
EUSCLTDZZSPEZZ
EUSCLTDZZGPEZZ
EUSCLTDZZTPEZZ
EUSAPPDZTSPEZZ
EUSAPPDZSSPEZZ
EUSAPPDZMSPEZZ
EUSAPPDZLSPEZZ
EUSAPPDZXSPEZZ
EUSOPEDZZSPEZZ
EUSLCCDZZSPEZZ
EUSLRCDZZSPEZZ
EUSVCCDZZSPEZZ
EUSVRCDZZSPEZZ
EUSSISDZZSPEZZ
EUSSISDZZGPEZZ
EUSSISDZZTPEZZ
Inthespecificcaseoforderinganupdateoranupgrade,itisnecessarytoprovidetheactivation ID of the license that needs to be updated.Withthisinformation,anewcodewillbe sent that will enable the user to update the existinglicense:Step1:thecustomerprovidestheactivationIDof the license he wants to update. The license activationIDmustbefilled-inwhenplacingtheorder.Step2:AnewactivationIDissenttothecustomer (email) when the order is processed. Step3:throughthelicensemanagerinstalledonthecomputer,thecustomeropenstheupdatemenu.HewillbeaskedtoentertheactivationID he received by email. The licensing system updates the original license for V4.3.
Update orders cannot be grouped and must be managed as individual orders. It is imperative to not mix activation IDs in the same order.
Note:thisorderingprocessisusedalsotoorder upgrade licenses. Ordering updates and upgradesfollowsthesameworkflowasnewlicenses.Refertothechapter“OrderingPES”.
List of References
6.1 List of References
ProcessExpertSystemMINI
EUSMINZTSPEZZ SWPEMINICONFWITH200OBJINSTLIC
EUSMINGZASPEZZ SWPEUPGMINITO500OBJINSTLIC
Process Expert System for End Users
EUSBEUCZZSPEZZ SWPEENGSINGLELIC
EUSCLTCZZSPEZZ SWPEENGCLIENTSINGLELIC
EUSCLTCZZGPEZZ SWPEENGCLIENTGROUPLIC
EUSCLTCZZTPEZZ SWPEENGCLIENTTEAMLIC
EUSAPPCZTSPEZZ SWPEAPPLLICEXTRASMALL
EUSAPPCZSSPEZZ SWPEAPPLLICSMALL
EUSAPPCZMSPEZZ SWPEAPPLLICMEDIUM
EUSAPPCZLSPEZZ SWPEAPPLLICLARGE
EUSAPPCZXSPEZZ SWPEAPPLLICEXTRALARGE
EUSOPECZZSPEZZ SWPEOPERSERVERLIC
EUSLCCCZZSPEZZ SWPECTRLCLIENTLIC
EUSVCCCZZSPEZZ SWPEVIEWCLIENTLIC
EUSLRCCZZSPEZZ SWPEREDUNDANTCTRLCLIENTLIC
EUSVRCCZZSPEZZ SWPEREDUNDANTVIEWCLIENTLIC
EUSAPPGZASPEZZ SWPEUPGXSTOSAPPLIC
EUSAPPGZESPEZZ SWPEUPGSTOMAPPLIC
EUSAPPGZHSPEZZ SWPEUPGMTOLAPPLIC
EUSAPPGZKSPEZZ SWPEUPGLTOXLAPPLIC
Upgrading a license leads to a delivery for the same version as the original one.
Process Expert System Engineering for ASC
EUSBASCZZSPEZZ SWPEENGASCSINGLELIC
EUSBASCZZGPEZZ SWPEENGASCGROUPLIC
EUSBASCZZTPEZZ SWPEENGASCTEAMLIC
Process Expert System Engineering for System Integrators
EUSSISCZZSPEZZ SWPEENGSYSINTSINGLELIC(1user)
EUSSISCZZGPEZZ SWPEENGSYSINTGROUPLIC(3users)
EUSSISCZZTPEZZ SWPEENGSYSINTTEAMLIC(10users)
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT
SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
List of References
Process Expert System Engineering for Alliance Partners
(asanoptionforSIswhojoinedtheSchneiderElectricAlliancePartnerProgram)
EUSBALCZZGXEZZ SWPEENGALLGROUPLIC
Process Expert System for Educational entities
EUSBASEZMSPEZZ SWPEEDUCENGSINGLELIC
Process Expert System for demonstration (Sales)
EUSSSVZZSPEZZ SWPESALESLICENSE
License updates from former version to V4.3
EUSMINDZTSPEZZ UPDATESWPEMINI200OBJLIC
EUSMINDZSSPEZZ UPDATESWPEMINI500OBJLIC
EUSBEUDZZSPEZZ UPDATESWPEENGSINGLELIC
EUSCLTDZZSPEZZ UPDATESWPEENGCLIENTSINGLELIC
EUSCLTDZZGPEZZ UPDATESWPEENGCLIENTGROUPLIC
EUSCLTDZZTPEZZ UPDATESWPEENGCLIENTTEAMLIC
EUSAPPDZTSPEZZ UPDATESWPEAPPLLICEXTRASMALL
EUSAPPDZSSPEZZ UPDATESWPEAPPLLICSMALL
EUSAPPDZMSPEZZ UPDATESWPEAPPLLICMEDIUM
EUSAPPDZLSPEZZ UPDATESWPEAPPLLICLARGE
EUSAPPDZXSPEZZ UPDATESWPEAPPLLICEXTRALARGE
EUSOPEDZZSPEZZ UPDATESWPEOPERSERVERLIC
EUSLCCDZZSPEZZ UPDATESWPECTRLCLIENTLIC
EUSLRCDZZSPEZZ UPDATESWPEREDUNDANTCTRLCLIENTLIC
EUSVCCDZZSPEZZ UPDATESWPEVIEWCLIENTLIC
EUSVRCDZZSPEZZ UPDATESWPEREDUNDANTVIEWCLIENTLIC
EUSSISDZZSPEZZ UPDATESWPEENGSYSINTSINGLELIC
EUSSISDZZGPEZZ UPDATESWPEENGSYSINTGROUPLIC
EUSSISDZZTPEZZ UPDATESWPEENGSYSINTTEAMLIC
The software is downloadable from the Schneider Electric portal (no hardware media supplied). Registration is required to access to the website (www.pes.schneider-electric.com).
Process Expert System Libraries
7.1 Introduction
ProcessExpertSystemprovidesresources:• Thathavebeenpre-configuredandtestedbySchneiderElectric.• Thatwerespecificallydesignedforautomatingalargevarietyofprocesses.The control resources for the Control and monitoring resources for Operator Interface provide the commonly required functions to facilitate the development of the DCS application.
StruxureWarePEincludesglobaltemplatesorganizedthroughtheFoundationandGeneralPurposelibraries.OptionallibrariestoaddressspecificneedsinmarketsandapplicationscanbeinstalledasoptionsontopofStruxureWare PE.Figure 22showsanoverviewoftheGeneralPurposeandoptionallibrariesavailablewithPESV4.3:
ThesystemprovidesControlfunctionblocks(DFB)atthecontrollevel,anddynamicrepresentations(Genies)atthesupervisionlevel.Inaddition,readyto-usefaceplates(implementedthroughwindowswithSuperGenies syntax) enable the users to get the status and interact with the process at the monitoring level.Toautomateandsimplifytheimplementationofautomationsystems,projectdesignerscanusetheseresourcestogetherformassivecodegenerationandforthesynchronizationofcontrolandsupervision.
Figure 22: PES General Purpose and Market/Application Libraries
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
Process Expert System Libraries
7.2 Global templates libraries
Globaltemplatesincludetwolibraries:• Foundationlibrary,whichincludeselementaryobjecttemplates.Generally,thesetemplatesarenotusedas singletemplates,butcombinedwithothersascompositeswithmorevalue-addedfeatures.Thislibraryis requiredtodesignhome-madetemplates.
• GeneralPurposelibrary(GPL),whichembedscompositetemplatescorrespondingtoaprocessfeature,asa controlmodule.AutomationsystemsaredesignedwithobjecttemplatesfromtheGPL,andobjectsmayalsobe usedfromtheoptionallibrariesandhome-madetemplates
TheGeneralPurposeLibraryisorganizedincategoriesaccordingtotheirpurpose.
7.2.1 Four main categories of templates1. Process templates• Signal conditioning and processing• On/off device control• Analog device control• Process control• Sequential control• Auxiliary functions
2. Devices• Circuitbreakers• Digital protective relays• Motorcontrolandstarters• Power monitoring devices• Progressive starters• Variable speed drives
3. Communication• EthernetModbusTCP• Modbusserial
4. Diagnostics• ModiconM340CPU• ModiconQuantumCPU• ModiconM580CPU
Figure 23givesanoverviewoftheseobjecttemplates.MostofthemembedgraphicalrepresentationsastherecouldbemanyrepresentationsofthesameobjectthatcanbeusedintheOperatorInterface.Someexamplesaregiven as follows.
Process Expert System Libraries
Figure 23: GPL Library: signal processing / calculation
Figure 24: GPL Library: process control
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
Process Expert System Libraries
Figure 25: GPL Library: device control management / controller diagnostics
Figure 26: GPL Library: automation and generic devices
Process Expert System Libraries
Figure 27: GPL Library: power and misc. devices
7.2.2 Configuration to edit and create instances of templatesEvenifitisrecommendedtominimizethedevelopmenttimetousepre-definedtemplate,anyconfigurationofPESforengineeringenablesthedesignoftemplates.Thisdesigncanbedonefromscratch,orfollowingacopyofanexistingtemplateoftheGPLlibraryanditscustomizationtofulfilltheprojectrequirements.Refertotheparagraph“Engineering”todiscoverthesoftwarelicensesenablingtheengineering.
7.3 Advanced Process Control Library
7.3.1 Presentation
AdvancedProcessControlLibraryconsistsof18functionsblocksformonitoringandcontrollingcomplexprocesses in the plant.
TheAPCLibraryforthePESofferincludes:• APC Standard Library• PCR Library• IMCLibrary
The APC Standard Library includes the following functions:
PID Block-StandardPIDfunctionwiththeabilitymanagethecompleteloopfromasingleplace.Datafromtransmitterandpositioner(value,statusandmode)areseamlessintheloopandusedforcalculations.Upstreamobjectinformationtransferstothedownstreamobjects.
Enhanced PID Block-ThisisanenhancedandcompletedPIDblockwithfeedforwardgainfordisturbancecompensation and override function by copying the actuator current status (RCPY). Auto tuning functionality is embeddedinthisblock.
Analog Acquisition Block-Analoginputwithsignalfiltering,squarerootextractionandprocessanalyst.
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
Process Expert System Libraries
Analog Positioner Block-Analogoutputwithabilitytoloopbacktheoutputdata(value,statusandmode)withupstreamobjecttodownstreamobjectsinformationtransferfeature.
De-multiplexer Block-Auxiliaryblock;transferssinglecontroloutputto4positioners.Upstreamobjecttodownstreamobjectsinformationtransferfeature.
Choice Block-Auxiliaryblock;select1of4inputsignalsbyPLClogicandmanual.Selectionisbump-less.Priority management is also possible.
Set Point Block-Auxiliaryblock,usedtocreateafilteredsetpointwithupstreamobjecttodownstreamobjectsinformationtransferfeature.
Ratio Block-Auxiliaryblock;ratiocontrolfunctionwithfiltering,trackingmodeandalarmdetection.Generallyusedincascademode,itsupportsaloopbackfromtheconnectedactuators.Errormodeormanualmodeoperationofactuatorsisusedinratiocontrol&PIDcalculationstopreventsaturation.
Split Block-Auxiliaryblock;splitrangefunctionwithtransformsananaloginputvalueinto2analogoutputsusingthecoordinatevalues,andchecksforthresholdoverruns.Thevaluesandstatusofthedownstreamactuatorsareusedtoinitializetheloopandtopreventintegralsaturation.
Selection Block-Auxiliaryblock;thisblockisusedtoselectoneof3transmittersignalsbasedonlogicaldecisions,wherestatusoftheanalogoutputisloopedbackandmanagesdifferentmodes.Itchecksforthreshold overruns.
Vote Block-Auxiliaryblock;thisobjectisusedtocalculateameanvalueof3processvariables.Adeviationalarm occurs if the deviation between 1 input and the 2 others is greater than the set limit.
Wrapper Block–Auxiliaryblock;thisblockisusedforusing/linkingtheanalogactuatorsofotherlibraries(e.g.GeneralPurposeLibrary,WaterLibraryetc.)withAPClibraryblockswithoutlosingtheAPClibrary’skeyfeatureofupstreamobjectstatustransfertothedownstreamobject(i.e.back-in/back-outfeature).
The model based predictive control library includes the following functions:
AP_PSF1 Block-Predictivecontrollerfor1stordersimpleprocess.(Model:Km,Tm&Dm):simple,andconvenient for long time delays.
AP_PIF1 Block-Predictivecontrollerfor1storderintegrativeprocess.
AP_PZTR Block-Zonecontrolwithnon-lineartimeresponse.Thisblockisusedforautomaticallychangingtheclosed-looptime-responsewhentheprocessvariable(PV)isinsideoroutsideazone.
The internal model based control library includes the following functions:
AP_MSF1 Block-Internalmodelbasedcontrollerfor1stordersimpleprocesses.Itidentifiesafirstordersystem with pure delay (the transfer function of the process and the transfer function of closed loop (controller + process)).ThecontrollerAP_MSF1allowsastaticgainunitandaccelerationofthetimeconstantbyafactor'n’,where n is the gain speed.
AP_MIF1 Block-Internalmodelbasedcontrollerfor1storderintegrativeprocess.
AP_MRAMP Block-Anintelligentrampmanagementblock.ItisusedwithIMCcontrollersandallowsboththeAP_MSF1blockandAPMIF1blocktofollowaparallelpathtorampthesetpointandtojoinandfollowitprecisely.Trackingareferencetrajectory,andinparticularasetpointrampisnecessaryinmanyapplications.
Process Expert System Libraries
7.3.2 Reference
License tobeordered:EUSAPCCZMSPEZZSWPEAPCLibrary-Std+Model
Note:themaximumnumberofobjectinstancesallowedwiththeapplicationlicenseofaPESsystemconfigurationincludesthenumberofinstancescreatedwithlibrary.OnlyoneAdvancedProcessControlLibrarylicenseisrequiredforthePESprojectdeployedonsite.
7.4 Energy Management Library
7.4.1 Presentation
The EnergyManagementLibraryoffersmonitoringandmeasurementofelectricalandnon–electricalprocessobjects.IttakesintoaccountWAGES(Water,Air,Gas,ElectricityandSteam)inputs.Theseblocksarecapableofprovidingaggregatedenergyateachlevel,bygivinginformationtousersabouttheenergyconsumptiondata.TheEnergyMeasurementLibraryofferslibraryblockswhichconvertprocessmeasurementvalues(flows,temperature,pressure,current,voltage)intoenergymeasurementvalues(kW/kWh).ThesevaluesareformattedtocomplywiththeODVAenergyobjectstandards.Theenergymeasurementlibraryalsoallowstheseblockstobeaddedandsubtracted,providinganapproximateenergymeasurementforhigherlevelswithintheprocess hierarchy. This enables the energy consumption and the process to be compared to alarm conditions and for energy to be monitored constantly but only alarmed when issues occur. The energy measurement libraries act as enablers for both the energy performance architectures used by Schneider Electric to perform overall energy management and also the energy performance services which provide Schneider Electric’s expertise to customers as a service.
Figure 28: APC Library: example of use in a glass furnace
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
Process Expert System Libraries
The Energy Management library contains following functions:
Aggregator-itaggregatestheenergyvaluesfromtheenergyobjectsconnectedtothisobject.Itprovidestheinstantaneous energy and the total energy in local units.
Gas–itcalculatestheenergyproduced/consumedbygasfuel.
Electric–itcalculatestheenergyproduced/consumedbyanelectricalcircuit.Itisabletocalculateenergyforsinglephaseandthree-phasecircuits.
Boiler–itcalculatestheamountofenergythatisconsumedtoproducesuperheatedsteamfromwater.
Aircomp-itcalculatestheratiosofpressureandvolumeflowratetoenergyconsumption.Thesevaluesarekeyperformanceindicators(KPIs)oftheaircompressorandgiveanindicationofitsefficiency.
Liquid-itcalculatestheenergyproduced/consumedbyliquidfuel.
CO2-itcalculatestheCO2equivalentinkgforanamountofenergy.
ProcessEnergy-itcomparestheactualenergywiththemodelledprocessenergytemplateforaparticularproduction period. This function can determine if the plant/area/section is consuming more or less energy than planned.
ProcessEnergyAdv–itcomparestheactualenergywiththemodelledprocessenergyadvancedtemplatefor a particular production period. This function can determine if the plant/area/section is consuming more or less energy than planned during this period.
Solid–itcalculatestheenergyproduced/consumedbysolidfuel.
Process Expert System Libraries
The Energy Management library includes the following services:
A standard way of communicating energy data• Energylibraryiscapableofprovidingenergydatainstandardizedform(kwh)whichcanbeaccessedacross the platform from device level. It is capable of providing energy equivalent information even in local units to users.
The energy consumption information at each level• Thecalculatedenergyvaluescanbeaggregatedatupperlevels,bygivinguserinformationabouttotal energyconsumptionatvariouslevelsinaplant.Withthisvalueinformation,userswouldabletotake appropriate action based on the total consumed energy.
Theenergydataforelectricalandnonelectricalenergyobjects• Thelibrarysupportsmeasurementofenergyconsumptionforelectricalenergy,gasconsumptionandvirtual measurement of energy. This can help the user in implementing a measurement solution for both electrical and non electrical plant components.
Energy monitoring• Dataobtainedfromtheenergylibraryhelpsuserstoknowthetotalenergyconsumptionoftheplantand thereforeanalyseandmonitorthekeyareas.
A data representation aligned to ODVA standards• Energy information displayed by the library is in line with ODVA data format.
Asetofenergyblocksforparametermeasurement• Energylibraryhasalsonon-energyrelatedblocksformeasurementofCO2emissions,pressure,andvolume flowconsumption.
7.4.2 Reference
Licensetobeordered:EUSEMLCZSSPEZZ SWPE Energy library Note:themaximumnumberofobjectinstancesallowedwiththeapplicationlicenseofaPESsystemconfigurationincludesthenumberofinstancescreatedwithlibrary.OnlyoneEnergyManagementLibrarylicenseisrequiredforthePESprojectdeployedonsite.
7.5 Mining, Metals and Minerals Library
7.5.1 Presentation
TheMiningMetals&MineralslibraryoffersallthecommonfunctionsrequiredbymostoftheMMMsegmentindustries.
ThislibrarycanbeenhancedwiththeCementandMiningLibraries,whichofferadditionalobjectsspecifictothissegment’s applications.
The MMM library includes the following services:
GroupManagement• A set of functions used in a process circuit are combined to form a group. The various functions or Control modules(motors,actuators,etc…)inagroupareadministeredandcontrolledgloballyasasingleentity(the group).Forexample,thetransportationofmaterialfrompiletohopperisdonebyusingmanyconveyorsand itinvolvesmanyactuators,motors,sensors.
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
Process Expert System Libraries
• Ability to group equipment• Managestart,stopofagroup,withasinglemanagementofinterlocks• Alarmmanagementofagroup:firstdevicefailurealarming,alarminhibitionandalarmandwarningmasking
RouteManagement• Differentsetsofdevicesthatbelongtosameoperationalgroup,performingsimilarfunctionalityandthat aremutuallyexclusivearecalled“routes”.Forexample,thetransportationofdifferentgradeofcementtosilos involving different sets of equipment (motors/actuators) • Managementoftherouting:selectionbetweenroutesandtocontrolthestartandstopofdevicesona selected route• Possibilitytomanage5routeswithaninstanceoftheobjectinthelibrary• Duringinitialization,thepre-defineddefaultrouteisselected.Later,theroutecanbeselectedbytheoperator fromHMIpopuporbyprocesslogicinthecontrollers.
Bagfilter• Bagfilterisacustombuiltsequencerblockforsupervisionandcontrolofthebagfilterpurgingoperation.This blocksupports18bags(18outputstosolenoidvalves).Thisblocksupportstheautomodeofoperation.
Beltconveyor• Thebeltconveyorobjectisthecustomizedmanagementofamotorwith1direction1speed,specificallyused forconveyorbeltsthatincludeinoperableconditionslikebeltswayandpullchord.Inaddition,italsochecks theprocessfeedback,suchaszerospeedswitches,beltrunningempty.Thisblocksupports3modesof operation:Auto,Manual,andLocal.
Inadditiontotheseprocessobjects,thelibraryincludes:• Asetofobjectsforequipmentcontrol:digital/analogsensorsandactuators,andseveralkindsofmotors.• Genericobjectswhichareusefulinprocessapplications:Totaliser,RatioControl,PID,andSchedulerfor energy
Figure 29: MM Library: route management
Process Expert System Libraries
7.5.2 Reference
License to be ordered:EUSMMMCZMSPEZZMMMLibraryforPESNote:themaximumnumberofobjectinstancesallowedwiththeapplicationlicenseofaPESsystemconfigurationincludesthenumberofinstancescreatedwithlibrary.OnlyoneMMMLibrarylicenseisrequiredforthePESprojectdeployedonsite.
7.6 Cement Library
7.6.1 Presentation
TheCementlibraryoffersspecificfunctionsthatarecommonlyrequiredincementplants.Cementworksareprocess applications that require a huge amount of energy and produce combustion gas from burners. In addition,equipmentisrunninginadustyenvironmentandsoitneedstobemonitoredcarefullytoensureitsavailability.TheCementlibrarycontributestobetterefficiencyoftheseprocessesthanksto:• Theenergyefficiencybymanagingmultifuelcontrol• Supervisionandcontrolofthegaswithagasanalyzeroperation• Girthgearlubricationcontrolwithmonitoringandwarningofthelubricationoiltanklevels
The Cement Library includes the following services:MultiFuelController• Control the ratio of ingredients of a continuous process• Designedtoincreasetheenergyefficiencybyincreasingthesecondaryfuelthroughput• Possibilitytocontrolupto6fuels:6setpointsaremanagedforindividualactuatorsandtomaintainaratio between6differentfuels.• SinglesetpointentrybyoperatorinGJ/htoincreasetheeaseofoperation• Monitoringoftheprocessfeedbackvaluecontinuously• Bump-lesstransferandunaffectedbyOnlinestart/stopofactuatorsThemainapplicationistomanageaKilnBurnerFuelRatio.
GasAnalyzer• Supervision and control of the gas analyser• Supports8analysertypes• Supports4gasparameters(O2,CO,NOx,SOx)• Processes the input parameters and holds the value during PurgingMainapplications:KilninletGas,PreHeaterOutletGas…
Girth Gear Lubrication control• Lubrication Valve status monitoring• Lubricationnozzlepositionstatus• Monitoringandwarningsforlubricatoroillevelintank,AirPressure,GreaseFlow,LinedifferentialPressure
TheMiningMetals&Minerals(MMM)libraryisalsodeliveredwiththeCementlibrary.TheMMMLibraryprovidesthreecategoriesoffunctionalservices:• Equipment Control• Asetofobjectsforequipmentcontrol• Genericobjectswhichareusefulinprocessapplications
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
Process Expert System Libraries
7.6.2 Reference
Licensetobeordered:EUSCEMCZMSPEZZ Cement Library for PES Note:themaximumnumberofobjectinstancesallowedwiththeapplicationlicenseofaPESsystemconfigurationincludesthenumberofinstancescreatedwithlibrary.OnlyoneCementLibrarylicenseisrequiredforthePESprojectdeployedonsite.
7.7 Mining Library
7.7.1 Presentation
TheMininglibraryoffersspecificfunctionsthatarecommonlyrequiredinminingplants.Itreducesengineering&deploymenttimewithtestedandvalidatedfunctionsfororerouting,separation,grindinganddryingprocesses.TheMininglibraryleveragestheoperationalefficiencywithfunctionsdesignedtoefficientlyoperateconveyors,hydrocyclones,thickeners,grindingmillsanddryers.Itprovidesoperationalanddiagnosticdatawithadvancedalarm monitoring to better manage the process.
The Mining library includes the following services:
Belt Conveyor–Thisfunctionblockisusedtocontrolthesolidfeedflowontheconveyorbeltbymaintainingthespeedofthebeltconveyormotor.Itmonitorsthespeed,thetotalmassflow,thematerialheightandmaterialweightonthebelt.Ittotalizesthematerialflowonthebelt.
Wet Grinding Mill–Thisfunctionblockisusedtocontrolthewetgrindingprocessusingatubulartypemill(Ballmill,AGmill,andSAGmill).TheaimoftheWetGrindingMillblockistomaximizethegrindingtoaspecifiedproductsize.
HydroCyclone-Thisfunctionblockisusedtocontroltheprocessofclassificationorseparationofcoarseandfineparticles.Itcanbeusedforasinglehydrocyclonetocontroltheseparationprocessorforahydrocyclonebanktocontroltheseparationinaseriesofcyclones.Itmonitorsthemassbalance.
Thickener-Thisfunctionblockisusedtocontrolsedimentationseparationofsolidandliquidmixtureinminingindustry.Thecontrolobjectiveistomaintaintheoverflowclarity(lowsolidcontentisrequired)andtheunderflowconcentration(highsolidcontentisrequired)atpredefinedsetpoints.
Rotary Dryer-Thisfunctionblockisusedtocontrolthedryingprocessusingarotarydryer.Rotarydrumdryersareused,notonlyinmining,butalsoinavastrangeofdryingapplicationsacrossanumberofindustries.Theblockcontrolsthemoisturecontentinapre-determineddesiredrangeandmaximizesthroughput.Also,thetemperature of the exhaust gas is controlled when it is used as a feed in another process.
Spiral -Thisfunctionblockisusedtocontroltheprocessofclassificationorseparationofcoarseandfineparticles in a vertical spiral concentrator. It monitors the input and output densities. It calculates the differential massflow,theinputmassflowandtheoutputmassflow
PID Advanced Block–Thisfunctionblockisusedtohaveaproportional,integral,andderivativecontrolover an actuator to maintain a process value close to a given target.
Two Loop PID Control Block–Thisfunctionblockisagenericcontrolblock.ItcanbeusedwhentwoPIDsarerequired,eitherinindividualcontrolorincascadedcontrol.
Four Loop PID Control Block–Thisfunctionblockisagenericcontrolblock.ItcanbeusedwhenfourPIDsarerequired,eitherinindividualcontrolorintwocascadedcontrolloops.
Process Expert System Libraries
TheMiningMetals&Minerals(MMM)libraryisalsodeliveredwiththeMininglibrary.TheMMMLibraryprovidesthreecategoriesoffunctionalservices:
• Equipment Control
• Asetofobjectsforequipmentcontrol
• Genericobjectswhichare useful in process applications
7.7.2 Reference
Licensetobeordered:EUSMNGCZMSPEZZMiningLibraryforPESNote:themaximumnumberofobjectinstancesallowedwiththeapplicationlicenseofaPESsystemconfigurationincludesthenumberofinstancescreatedwiththelibrary.OnlyoneMiningLibrarylicenseisrequiredforthePESprojectdeployedonsite
7.8 Liquid Food Library
7.8.1 Presentation
TheLiquidFoodLibrary(LFL)providesasetofobjects,whicharedesignedtoperformdevicefunctionsonspecializeddevicesusedintheFoodandBeverageindustryandprocessfunctionstooperatetheprocessoperationsintheplant.TheseobjectshelptodesignautomationsystemstocomplywiththeISAS88batchprocessengineeringmodel.LiquidFoodLibraryobjectscanbecombinedwiththeGeneralPurposeLibrarytodesignaliquidfoodapplicationsolution.Thisassociationprovidesacosteffectiveandhighvalue-addprocessautomation solution for liquid food producers. Thelibraryincludestwosetsofobjects:thedeviceobjectsandtheprocessmonitoring/controlobjects
Figure 30: Mining Library: example of wet grinding mill
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
Process Expert System Libraries
The liquid food library contains following device objects:
VLVCTL-2-way,3-way,4-wayOn-OffValvePneumaticLoadManager.
PLGCTL-LeakageChamberSeatLiftingActuator
VLV1PLGCTL-3-waymixproofvalvewithoneleakagechamber
VLV2PLGCTL-4-wayMixproofvalvewithone/twoleakagechambers
MOTORCYC-CyclicMotoroperation
ENODE4T, ENODE4T_LIGHT-WeighingModule-Scaimeweightmodules
The liquid food library contains the following process monitoring and control objects:
EQUIP-Providesthesupervisionandthestatusinformationoftheequipment.
SELPRESEL-isusedforselectionorpre-selectionoftheprocessequipmenttocarryoutoperationsonit
SEQCTL2 -Theblockimplementsthesequencestatusmanagementandprocessesthecommandsreceivedfrom the monitoring subsystem or by other control sequences in program mode.
SEQFCT-ThefunctionblockexecutesasequencefunctionforaprocessoperationaspertheguidelinesfollowedinSEQCTL2.TheSEQFCTsupportstheprocessfunctionssuchastransferofthematerialfromoneitemofequipmenttoanother,agitation,andothers.
SEQFCTRECIPELINE-isbasedonSEQCTL2functionblock,withenhancedfeatures,toexecuteasequenceoffunctionsbasedonapredefinedrecipe.
SEQCTL3_PLI -thecontrolobjectimplementsthesequencestatusmanagementandprocessesthecommandsreceivedfromthebatchcontrolsubsystem(thesubsystemsendsthecommandsandchecksthestatusofthesequencetodeterminewhatactionhastobetaken).Thisblockimplementsthephaselogicinterface (PLI) to interface with the batch control system software.
SEQCTL3FCTBATCH-combinedwiththeSEQCTL3_PLIcontrolobject,itcanmanage30initialconditions,30failureconditions,16processinputparametersand16processoutputparameters
CIP Recipe Management -CIPRecipeManagementisanassemblyfunctionusedforconfiguringCIPrecipes and corresponding recipe parameters to clean equipment or a process line.
Parameter Management -TheParameterManagementfunctionisnormallyusedtotransferasingleorsetof parameters from SCADA to PLC or vice versa.
Figure 31: LFL Library: example of use (transfer in tanks)
Process Expert System Libraries
7.8.2 Reference
Licensetobeordered:EUSLFLCZSSPEZZ LFLLibraryforPESNote:themaximumnumberofobjectinstancesallowedwiththeapplicationlicenseofaPESsystemconfigurationincludesthenumberofinstancescreatedwithlibrary.OnlyoneLiquidFoodLibrarylicenseisrequiredforthePESprojectdeployedonsite.
7.9 Water and Waste Water Library
7.9.1 Presentation
TheWater&WasteWaterlibraryprovidesasetofgenericfunctionsthatarecommonlyusedinwaterandwastewaterapplications.Thelibraryhelpsinthemanagementofmultiplepumpsandtime-basedschedulingof operations on equipment and devices to simplify remote operations. Local mode operation of equipment on remotepumpingstationsispossible.Objectsinthewaterlibraryprovidethecapabilitytomanageenergybyload shedding.
The water library contains following device objects:
WPENSTOCK (Penstock Valve Control)-TheWPENSTOCKfunctionblockisusedtomanagetheoperationandcontrolofamotoroperatedpenstockvalve/gateinanOpen-Stop-Closeoperation.
WPUMPSEL1 (Pump Selection)-TheWPUMPSEL1blockisusedforcheckingstatusandforcontrollingoperationsofamaximumfivepumpsondemandbasis.
WDFMCTL (Dual Media Filter Control)-ThefunctionblockrepresentsindividualDMFfiltersandselectsvariousoperationsperformedbythefilter
WFLOWCALC (Flow Calculation)-Thisfunctionwillcalculatethedischargeflowintheopenchannelforvariousconstructionslikeweirs,flumes,notches
WFLOWCTL (Flow Control) -Thisblockistoallowchemicalfeedcontrolbasedonflow,butallowfinetuningbasedonStreamingCurrent.Theflowbasedportionoftheformulawillbebasedonaratiothatcompares the maximum the pump can produce to a desired concentration.
WAERACTL (Aeration Control)-TheWAERACTLfunctionblockisusedtomanagetheoperationandcontrol of an aeration control valve. It gives a command to the valve which controls the amount of oxygen supplied to an aeration control basin.
WPUMPSEL (Pump Selection)-Itchecksthestatusandcontrolstheoperationsofamaximumof5pumps.Itcalculatesthenumberofoperationalhoursforeachpump.Aftercompletionofamaximumofoperationalhours,theobjectswitchesoperationtoanotherpumpinstandby.Itchecksthehealthofeachpumpand to ignore it when it is not ready for operation. It is possible to switch between pumps by using the buttons in the faceplate when in manual mode.
WSCHEDULER (Scheduler) –Itallowsthemodeofoperationofequipmenttobescheduled.TheoutputcanbeusedtosetaPIDvalue,acontrolvalveoutputorthespeedofamotor.Thescheduleriscapableofholding information for up to 10 events.
WMOTOR-Tocontrolamotorwith1directionand1speed.
WMOT1D2S-Tocontrolamotorwith1directionand2speeds.
WMOT2D1S–Tocontrolamotorwith2directionsand1speed.
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
Process Expert System Libraries
WMOTORVS-Tocontrolamotorwithavariablespeeddrive,whetherthespeeddriverisswitchedthroughcommunications,I/Owiring,oramixtureofboth.
WVALVE–Tocontrolanon-offadeviceasanon-offvalvewith2limitswitches(e.g.electro-pneumaticvalve).
WMVALVE-Tocontrolamotorizedvalvewithapositioner.
WMVALVED-Tocontrolanon-offmotorizedvalveasagatewith2limitswitches.
The water library includes the following functions:
• Managementofmultiplepumps(upto5pumps)
• Time-basedschedulingofoperationsonequipmentanddevicestosimplifyremoteoperations
• AlarmsandinterlockmessagescanbesentviaSMSthrougha3rdpartysystem
• LocalModeoperationofequipmentinremotepumpingstations
• EnergyManagementbyloadsheddingfunctionalitiesembeddedinobjects
7.9.2 Reference
Licensetobeordered:EUSWWWCZSSPEZZ WWW Library for PES Note:themaximumnumberofobjectinstancesallowedwiththeapplicationlicenseofaPESsystemconfigurationincludesthenumberofinstancescreatedwithlibrary.OnlyoneWaterLibrarylicenseisrequiredforthePESprojectdeployedonsite.
Figure 32: Water Library: example of use (pumping station)
Managing Licenses
This chapteraddressesthemanagementoflicenses,coveringthefollowingareas:
• Activation of a license
• Managementoflicenses;useoftheSoftwareLicensingPortal
• Policy applicable for the licenses
8.1 Activation of a license
Ordering a PES license provides an entitlement containing one or several activation IDs corresponding to the software licenses ordered. This entitlement is sent to the user through an email (refer to the ordering chapter for more information).ThelicensemustbeactivatedontheSchneiderElectricSoftwareLicensingservertobeoperational.Takenote that it is not possible to use PES without having activated the licenses (no trial period is allowed). Three methodsareavailabletoactivatethelicenses.ThisisdonethroughthefloatinglicensemanagerthatisinstalledonthecomputerwithPES:
1.ThroughWeb.ItrequiresanInternetconnectionontheworkstation.Thisistheeasiestwayanditisimmediate.
2.ThroughtheSoftwareLicensingPortal.ThismethodallowslicensestobeactivatedonaworkstationthatisnotconnectedtotheInternet.Activationtakesafewminutes.Thefollowingstepsarerequired: •Fromtheworkstationthatembedsthelicenses,invoketheregistrationvia“WebPortal”.Itleadstocreating afilethatneedstobestoredonaremovablemedia,asaUSBkey. •FromanothercomputerthathasaccesstotheInternet;gototheSoftwareLicensingPortal.Thelicensing serviceintheportalallowsthefiletobetransferredfromtheoriginalworkstationandthecreationofanew filethatwillberestoredontheworkstation. •Completetheactivationofthelicensewiththisnewfileontheworkstationthroughthefloatinglicense manager.
3.ThroughEmail.Thismethodrequires1or2daystoactivatethelicense.Activationisdoneintwosteps: •Fromtheworkstationthatembedsthelicenses,invoketheregistrationvia“Email”.Itleadstocreateafile that has to be sent by email from this machine or another one to a Software Registration Center. •ThefilereceivedasresponsetotheemailfromtheSoftwareRegistrationCentermustbecopiedonthe workstationpriortoactivatethelicensewiththisfilethroughthefloatinglicensemanager.
8.2 Management of licenses with the Software Licensing Portal
The Software Licensing Portal enables the users to administer their licenses. Any customer can create his own privateworkingspacefollowingtheregistrationtotheSoftwareLicensingPortal(www.schneider-electric.com/tab:Support/menu:SoftwareLicensing).Fromhisspace,theusercangainaccesstothelistofhislicensesandgetthestatusforeachofthem.Withoutanylogin,itisalsopossibletogetthestatusofonelicense,simplyentertheactivationIDtogettheinformation.The Software Licensing Portal is also the place to activate a license through the Web Portal.
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
Managing Licenses
8.3 Policy applicable for the licenses
Followingtheactivationofalicense,thestatusofthislicensecanbecheckedontheSoftwareLicensingPortal.Theusermayhavetodothefollowingactivitiesforalicense:
•“Rehost”:ReturnthelicensebackfromtheworkstationtotheSoftwareLicensingPortal.Thelicenseisno longer active on the computer. It can be activated on another computer. This is the usual way to move a license from one machine to another one.
•“Repair”:Followingthecrashoftheworkstation,itallowsthelicensetoberecoveredonthesamemachine. Inthatspecificcase,PESisre-installedonthesamemachine.Throughthe“Repair”service inthelicensemanager,itenablesthelicensetoberecoveredonthemachine,afterenteringthe activation ID. This activity doesn’t need any external support.
•“Reinstall”:Followingthecrashoftheworkstation,itallowsthelicensetoberecoveredonanothermachine afterre-installationofPES.Whenthemachinehaschanged,thelicensingsystemcannot relyonmachineinformationtoactivatethelicense,becausethemachinehaschanged.Reinstallationof the license requires the assistance of the Software Registration Center.
Figure 34belowgivesthepolicyapplicableforeachtypeofactivity.Thenumberofactionsisdefinedperyearand it depends on the number of seats that are attached to this license.
Figure 33: Software Licensing Portal on schneider-electric.com
Figure 34: Policy applicable to the software licenses
Hardware requirements to run Process Expert System
DuetovariouscriteriatoknowtheCPUperformance,therequiredprocessorisdefinedaccordingtoanaverageCPUmarkgivenbyPassMark(R)Software.
TocheckaCPUperformance,forexampleforaCorei3CPU,type“passmarkCorei3”inthesearchengineofyourInternetnavigatortogetthelistofknownprocessorsandgettheaverageCPUmarkforaselectedone.
Workstation embedded with the System Server
System:processorwithaverageCPUMark:5000minimum
RAMmemory:8GBminimum,16GBrecommended
Harddisk:250GB/Fastdisk7200rpm;format:NTFSfilesystemandnotFAT32
40GBoffreememoryspaceontheharddiskisrequiredtoinstallandrunthesoftware
Recommendeddisplay:SVGA(1024-768ormore)withhighcolor24bits
Pointingdevice:mouseorcompatibledevice
Operating system on the physical machine
• Windows server 2012 R2 (recommended)
•Windows10Pro,Windows7ProorWindows8.1Pro64-bit
Workstation embedded with an Operation Server
System:processorwithaverageCPUMark:3000minimum
RAMmemory:4GBminimum,8GBrecommended
Harddisk:80GB(SSDrecommended)/Fastdisk7200rpm
Operating system on the physical machine
• Windows server 2012 R2
•Windows10Pro,Windows7ProorWindows8.1Pro64-bit
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
Hardware requirements to run Process Expert System
Workstation embedded with the System Server
System:processorwithaverageCPUMark:5000minimum
RAMmemory:8GBminimum,16GBrecommended
Harddisk:250GB/Fastdisk7200rpm;format:NTFSfilesystemandnotFAT32
40GBoffreememoryspaceontheharddiskisrequiredtoinstallandrunthesoftware
Recommendeddisplay:SVGA(1024-768ormore)withhighcolor24bits
Pointingdevice:mouseorcompatibledevice
Operating system on the physical machine
• Windows server 2012 R2 (recommended)
•Windows10Pro,Windows7ProorWindows8.1Pro64-bit
Workstation embedded with an Operation Server
System:processorwithaverageCPUMark:3000minimum
RAMmemory:4GBminimum,8GBrecommended
Harddisk:80GB(SSDrecommended)/Fastdisk7200rpm
Operating system on the physical machine
• Windows server 2012 R2
•Windows10Pro,Windows7ProorWindows8.1Pro64-bit
Workstation embedded with an Engineering Client
System:processorwithaverageCPUMark:3000minimum
RAMmemory:8GBminimum
Harddisk:250GB/Fastdisk7200rpm;format:NTFSfilesystem
Operating system on the physical machine
•Windows10Pro,Windows7ProorWindows8.1Pro64-bit
Workstation embedded with an Engineering & Operation Client
System:processorwithaverageCPUMark:3000minimum
RAMmemory:8GBminimum
Harddisk:250GB/Fastdisk7200rpm;format:NTFSfilesystem
Amouseandakeyboard
Operating system on the physical machine
•Windows10Pro,Windows7ProorWindows8.1Pro64-bit
Workstation embedded with an Operation Client
System:processorwithaverageCPUMark:2000minimum
RAMmemory:3GBminimum
Harddisk:250GB/Fastdisk7200rpm
Amouseandakeyboard
Operating system on the physical machine
•Windows10Pro,Windows7ProorWindows8.1Pro64-bit
Service Support associated with Process Expert System
10.1 Introduction
SellingservicesassociatedwithPEScombinesbenefitseitherforCustomersandSchneiderElectricfordifferentreasonsthatareexplainedbelow:
Benefitsforthecustomer:• Majorcostsavings• Improved production performance • Expertandprofessionalsupport-receivefastandaccurateanswers• Access to version upgrades (1+ release per year)• Protect their automation investment
BenefitsforSchneiderElectric:• Increased revenue • Customer contact opportunities • Increased customer satisfaction • Moresupportsalestoolsthaneverbefore
The Service Support is part of an overall set of services that are deployed progressively for Process Expert System.
Figure 35: Maintenance and Support Services overview
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
Service Support associated with Process Expert System
10.2 Service Support definition
Three levels of support are available as options to the software offer. There are presented from the highest value,combiningsupportandsoftwareupgrades,tothelowestincludingonlysupport.InthespecificcaseofPES,itismandatorytocombinethesellingoflicenseswithasupportservice.SilverSupport is the minimum required.
GoldPlus Support
• Level3Support–24x7access
• On line technical information
• Version upgrades
• Priced approximately as 20% of the total amount of the software list price. This premium support offer is attractive to customers with high availability systems in which downtime is expensive.Itcoversthesupporttoa24x7.
Gold Support
• Level3Support-LocalBusinessHours(MON-FRI)
• On line technical information
• Version upgrades
• Pricedapproximatelyas15%ofthetotalamountofthesoftwarelistprice. Thisisthestandardserviceoffer,whichcombinessoftwareupgradesandsupportduringbusinesshours.Thisisthe common choice that should be proposed to customers by default.
Silver Support
• Level3Support-LocalBusinessHours(MON-FRI)
• On line technical information
• Priced approximately as 10% of the total amount of the software list price. This is a light support offer aimed at customers who want to be able to receive assistance for their installed applications but do not intend to upgrade. This is the minimum support to be combined with PES licenses.
Support to Process Expert System is managed via our central call centers and is only available in certain languages.
Service Support associated with Process Expert System
10.3 Contents of the Support Services
Silver,GoldandGoldPlussupportsincludethefollowingservices:
1. Direct Access Support
Theserviceprovidesaccesstotechnicalassistanceviatelephone,livechat,andemail.Thecustomergetsfast access to experienced Support Engineers based in dedicated labs where they can replicate the customer configurationandreproduceissuesexperiencedonsite.ThesupportserviceisnotexpectedtoengineeraCustomer’sprojectorresolveissuesspecifictotheCustomer’sapplicationimplementation.
2. Online Support Tools
UseofadedicatedPESGlobalSupportportal(www.pes.schneider-electric.com)toaccessarangeofsupporttools including live chat and case manager for easy online case monitoring.
3. Emergency Support
Customerobtainsemergencysoftwarehotfixesviaanintensifiedescalationprocessinsituationswherecriticalissues are impacting upon business operations.
4.CustomerServiceRequest(CSR)ResolutionWorkflow
Arigidframeworkofissueprioritizationandseverityensuresthatanappropriatemanagementprocessisappliedtoallthecustomerissuesuntilresolution.TheprioritizationdependsonthelevelofSupportservicetheCustomer has contracted. Silver and Gold Support services are managed with the same priorities. The technical resolutionworkflowisdescribedinFigure 36:
Figure 36: Escalation process to manage customer requests
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
Service Support associated with Process Expert System
5. Online Knowledge Base
Access theknowledgebaseanytimeforexpertknow-howandinformationthatsustaintheCustomer’sreturn on investment.
6. Real-Time News
TheCustomerstaysinformedaboutthelatestnewsandreceivessupportupdates,producttips,andotherinformation through the PES Global Support portal.
Accessing Remote technical support
ASupportServicescertificatewillbeawardedonpurchaseofSupport.Thiscertificateprovidesinformationthatwill be required when the customer wants to raise a Customer Service Request (CSR) or wishes to log onto in-supportCustomersdedicatedareasofthePESGlobalSupportwebsite.
10.4 Support fees calculation
Thecalculationofsupportisapplicabletoacustomersite.Thedefinitionofasiteisimportanttoensuresupportcanbecorrectlycalculated.AsitecontainsalltheSystemServer,Engineeringclients,OperationServersandOperation Clients which communicate together to access the application database which is located on the SystemServer.SoastandalonemachineincludingtheSystemServer,anOperationServerandanOperationClient can be considered as a site. Thedefinitionofasiteisregardlesshowthesoftwarepiecesaredistributedinoneorseverallocations,forexample in control rooms.
Inordertotakeinaccountthecomplexityandvariouspossibilitiesinconfigurationswhilehavingaslidingfeethatdependsonthesite,thecalculationisbasedonthepricingofthesoftwarepiecesthatarerunningandaprice depending on the value of the service.
Figure 37: Access and services from the Support Portal
Service Support associated with Process Expert System
TodothisthecostofsupportisbrokenupintoindividualSupportUnits.EachsoftwarelicensehasavalueintermofSupportUnits.TheUnitPricedependsonthelevelofsupportpurchased(GoldPlus,Gold,Silver). Itisappliedthefollowingcalculationruleforsoftwareservice:
Support Fee (for 12 months) = Unit Price x Quantity
Where:
Unit Price = Unit Price of the Support Level purchased
Quantity = Total Support Units of the software licenses
Important note: takingordersformixedlevelsofservicesisnotallowedforasite.Incaseofamixoflevelsinasite,theminimumlevelofsupportwillbeprovided.Torenewsupportonasite,thesupportpriceiscalculatedbasedonthelevelofsupportpurchased(GoldPlus,Gold,Silver)andthesoftwarelicensesonthecustomersite.
10.4.1 Table of units (quantity) for each license (part number)
The table below lists the software license part numbers and gives the equivalent in quantities of units to calculate the support.
PES system
Part numberEUSMINCZTSPEZZ
EUSMINGZASPEZZ
EUSBEUCZZSPEZZ
EUSCLTCZZSPEZZ
EUSCLTCZZGPEZZ
EUSCLTCZZTPEZZ
EUSAPPCZTSPEZZ
EUSAPPCZSSPEZZ
EUSAPPCZMSPEZZ
EUSAPPCZLSPEZZ
EUSAPPCZXSPEZZ
EUSOPECZZSPEZZ
EUSLCCCZZSPEZZ
EUSLRCCZZSPEZZ
EUSVCCCZZSPEZZ
EUSVRCCZZSPEZZ
EUSBASCZZSPEZZ
EUSBASCZZGPEZZ
EUSSBASCZZTPEZZ
EUSSISCZZSPEZZ
EUSSISCZZGPEZZ
EUSSISCZZTPEZZ
EUSBASEZMSPEZZ
Software License
DescriptionSW PE MINI CONF WITH 200 OBJ INST LIC
SW PE UPG MINI TO 500 OBJ INST LIC
SW PE ENG SINGLE LIC
SW PE ENG CLIENT SINGLE LIC
SW PE ENG CLIENT GROUP LIC
SW PE ENG CLIENT TEAM LIC
SW PE APPL LIC EXTRA SMALL
SW PE APPL LIC SMALL
SW PE APPL LIC MEDIUM
SW PE APPL LIC LARGE
SW PE APPL LIC EXTRA LARGE
SW PE OPER SERVER LIC
SW PE CTRL CLIENT LIC
SW PE REDUNDANT CTRL CLIENT LIC
SW PE VIEW CLIENT LIC
SW PE REDUNDANT VIEW CLIENT LIC
SW PE ENG ASC SINGLE LIC
SW PE ENG ASC GROUP LIC
SW PE ENG ASC TEAM LIC
SW PE ENG SYS INT SINGLE LIC
SW PE ENG SYS INT GROUP LIC
SW PE ENG SYS INT TEAM LIC
SW PE EDUC ENG SINGLE LIC
Quantity(Units)
91
47
117
31
63
94
47
94
188
313
469
63
55
0
19
0
7
14
33
47
94
188
31
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
Service Support associated with Process Expert System
Market/Applicationlibrariesfor PES
10.4.2 List of references for Support Service
EUSPES001 Silver support (Unit Price)
EUSPES011 Gold support (Unit Price)
EUSPES012 Gold Plus support (Unit Price)
10.4.3 Quote the Support fees - example
APESconfigurationonacustomersiterequiresthefollowinglicenses:• Anengineeringconfiguration+anadditionalengineeringclient• AnApplicationlicenseallowingaprojecttoberunwith3000objectinstancesmaximum(Mediumlicense)• One Operation Server plus 3 remote Control ClientsNote:AlocalclientisembeddedintheOperationServer
BillofmaterialandcalculationofUnitsforservicefees:
Thesalesrepresentativewouldquotetheservicesupportforthisconfiguration(Silverservice). TheUnitPriceforSilversupport(EUSPES001)is7€.Support Fee (for 12 months) = Unit Price x QuantitySupport fee (Silver) : 7x 595 = 4165 €
Part numberEUSAPCCZMSPEZZ
EUSWWWCZSSPEZZ
EUSMMMCZMSPEZZ
EUSCEMCZMSPEZZ
EUSMNGCZMSPEZZ
EUSLFLCZSSPEZZ
EUSEMLCZSSPEZZ
Software License
DescriptionSWPE APC Library - Std + Model
WWW Library for PES
MMM Library for PES
Cement Library for PES
SWPE MINING LIBRARY
LFL Library for PES
SWPE ENERGY LIBRARY
Quantity(Units)
47
31
47
55
64
16
16
Part number
EUSBEUCZZSPEZZ
EUSCLTCZZSPEZZ
EUSAPPCZMSPEZZ
EUSOPECZZSPEZZ
EUSLCCCZZSPEZZ
Description
SW PE ENG SINGLE LIC
SW PE ENG CLIENT SINGLE LIC
SW PE APPL LIC MEDIUM
SW PE OPER SERVER LIC
SW PE CTRL CLIENT LIC
QTY PN
1
1
1
1
3
Unit value QTY Units117
31
188
63
55
117
31
188
63
165
595Total number of units
Ordering Process Expert System
PESofferincludesthreekindsofpartnumbers:• Software licenses• Physicalproducts(packWindows,MagelisRackPCs,hardwareascontrollers,...)• Support services
Each type of offer needs to be handled differently. This paragraph describes the ordering procedure for each kindofpartnumbers
11.1 Software licenses
AllordersconcerningthelicensesforPESmustbeplacedtothelocalcountryorderingsystemwithMROCarrosasasupplier.Inaddition,theCountrymustfill-inadditionalinformationconcerningthelicenseitselfintheLicenseOrderingPortal(LOP).Oneimportantpointistoprovidethemailaddress(WUM@),whichwillbeused to automatically send the entitlement concerning the licenses to this address. Figure 38belowshowsthemainstepsofthisworkflow:
Figure 38: Ordering process for the PES licenses
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
INDUSTRIAL PC FOR
PROCESS EXPERT SYSTEM
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
Ordering Process Expert System
11.2 Ordering physical products
It is applicable to any physical product. This is the standard procedure applicable for any standard product. Theorderswillbeplacedinthelocalcountryorderingsystem(Bridge)
11.3 Ordering the Support for PES
SupportservicemustbeorderedthroughtheSalesOrderConfigurationtool(SOC).ToaccesstheSalesOrderConfiguratorsimplygotowww.soc.schneider-electric.com
SOCincludesanassistantthatenablestheservicestobequotedcorrespondingtoaPESconfiguration.ItcalculatesthenumberofunitsofaPESconfigurationenteredinSOCanditcreatesaquoteforthelicenses and the associated services. The quote can be transformed into a purchase order for the service only. The PurchaseOrderdoesn’tcoverthelicenses,whichmustbeorderedseparatelythrougheMRO.
Importantnote:Software licenses must be ordered prior to the Support Service through eMRO.Lateron,whentheSupportServiceassociatedwiththelicensesisordered,itisnecessarytomentiontheeMROpurchaseorderinthe“specialinstructionfield”oftheorderdetailsinSOC.
Industrial PC for Process Expert System
12.1 Introduction
MagelisHMIRackPCoffersone-stopshoppingforacompleteplantsolutionthathasbeentestedandvalidatedbySchneiderElectric,alongwithPlantStruxuresoftwareVijeoCitectandPESEngineering.MagelisHMIRackPCscanbeeasilyinstalledin19"enclosuresandconnectedtoMagelisiDisplayfordisplayscreen.TheMagelisRackPCparticularlyaddressescustomerneedsincontrolroomswherethereplacementcostsandenvironmentconstraints(Temperature,dust,EMC…)arelimited.
TheofferRackPC+PESdeliverthefollowinguniquevaluepropositions:ConsistentMagelisrange,tooperatethedifferentneedsofEcoStruxurearchitectures:
• Highperformancemodelforengineering(PESSystemServer)
• IntermediateperformancemodelforSCADAservers,withahighdutyharddrive.
Easeofintegrationincontrolroomwith19”rackformat
• Readytoincluderackinastandardcabinetincontrolrooms
Figure 39: The rack PC is located in the plant control room
ORDERING PROCESS EXPERT
SYSTEM
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
AUTOMATION PLATFORMS
SELECTION GUIDE
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
Industrial PC for Process Expert System
12.2 Offer description
12.2.1 Selection guide of Magelis Rack PC
HMIRSPHXA67P1andHMIRSPSXR6T01arespecificallyaddressingtherequirementsforPES system server. HMIRSUS3A3701,HMIRSPFXA6701&HMIRSPFXR6702arespecificallyaddressingtherequirementsforthesupervision (operation server and operation clients)
Automation Platforms selection guide
13.1 Overview
ThissectiongivesanoverviewoftheautomationplatformsthataresupportedinPES:ModiconM580,Quantum,andM340.Thisisasummaryofthekeyfeatures,basedonapresentationoftheplatformandmodules’ description from selection guides.
Elements of the automation platform architectures that are common to all platforms are described after the platforms.
Formoredetailsabouttheautomationplatforms,pleaserefertothefollowingcatalogs:• ModiconM580AutomationPlatform• ModiconQuantumAutomationPlatform• ModiconM340AutomationPlatform• ModiconX80I/OPlatform
Somearchitectures,hardwaremodules,orfeaturesembeddedinanautomationplatformarenotsupportedincontrolsystemsdesignedwithPES.Theselimitationsareidentifiedinthisdocumentwithan“(*)”inthemodule’sdescription,withanexplanatorynoteatthebottomofthemoduledescriptiontables.
Inaddition,thelastsectionofthischapterprovidesasummaryofallunsupportedmodulesforeachautomationplatform.
13.2 Modicon M580 automation platform
Limitations in the support of architectures or hardware modules in the scope of application designed for Process ExpertSystemarchitecturesareidentifiedinthisdocumentwithan“(*)”inthemodule’sdescription,withanoteat the bottom of the module description tables.
The last section of chapter section provides a summary of all unsupported modules for the automation platform.
13.2.1 General presentation
TheModiconM580ePAC(ProgrammableAutomationController)features openness,flexibility,robustness,andsustainability.TheM580isdesigned withanEthernetbackbonetooptimizeconnectivityandcommunications. ItsupportsX80I/Omoduleswhichcanbeeasilyintegratedintoits architecture. The powerful processors offer high levels of computation for complexnetworkedcommunication,display,andcontrolapplications.
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
ePAC concept• Top-to-bottomstandardEthernetnetwork
• OpenarchitecturewithdirectEthernetconnectiononthebackplane
Cybersecurity readyCybersecurityready,withAchillesLevel2certificationandadvanced, built-incybersecurityfeatures
• EmbeddedsecurityfeaturesasdefinedbystandardIEC62443
Automation Platforms selection guide
Advanced technologies• Basedonhigh-speeddual-coreprocessor(ARM®type)
• High-speedcommunication,application,andexecution
• InnovativemechanicalandelectronicdesignforhighEMCimmunityand ruggedness that is superior to the required IEC standards
• Supports extendedtemperaturerangefrom−25°Cto+70°C/-13°Fto+158°F
(continued)
High precision• Abilitytodeliver1msI/Oresolutionthroughnativetime-stampingat thesource,withspecifictime-stampingmodulesviaOPCserver
• Applicationsincludefunctionssuchas:
• Sequence of Events recording (SER)
• Utility substation automation
• Protective relay trip history
• Alarm / event logs
• Time-stampingofpowermonitoringdatalogs
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Flexibility in design• Flexibletopologyallowssimpleintegrationofdevices
• Ability tomixremoteequipment,distributedequipment,andotherdevicesonthe sameEthernetfieldnetworkwithcompletesoftwareintegration
• Transparent access to datathroughEthernetbackbone
• SimpleHMIintegrationviathirdportonremoteI/Ohead
• Interfacetootherpopularfieldbusanddevicenetworks,includingAS-Interface (*),Modbus,Profibus,andHART(*)
(*)ManagementofAS-InterfaceandHARTinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjectsinstantiation.
Automation Platforms selection guide
Optimized architecture• Simple daisy chain loop
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Helping to protect investments• StandardizeontheModiconfamilywithcommonX80modulesand reduce training and maintenance costs
• KeepyourexistingQuantumI/Oandwiring
• Smoothmigrationpathsforbothhardware(quickwiringadapter)and software (SW converters).
Automation Platforms selection guide
13.2.2 Architectures
13.2.2.1 Overview
Different architecturesTheModiconM580ePACoffersdifferentembeddednetworkstomeetvariousarchitectureneeds:• StandardEthernetDIOportsonBMEP58xx20processorsforlocalI/Oarchitecture,integratedfieldbus architecture,anddistributedI/O
• DualEthernetRIOportsonBMEP58xx40forremoteI/Oarchitecture
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
13.2.2.2 Examples of architectures
ThishardwarearchitectureisbasedonM380withX80dropsembeddingtheI/Os,combinedwithremotedevices on Ethernet.
InstrumentsareconnectedonHartI/OmodulesinaremoterackorthroughaProfibusDPremotemaster.
ManagementofHARTinPESapplicationsrequiresprogramminginadditiontothehardwareconfiguration andobjectsinstantiation
Automation Platforms selection guide
ThishardwarearchitecturetargetsawidecontrolsystemwithX80remoteracksconnectedthroughopticalrepeaterstoanM380mainrack.Inaddition,therearedistributedequipmentonEthernet,combinedwithinstrumentsonProfibusconnectedthrougharemotemaster.
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Redundant architecturesWithBEMH58xx40processorsdedicatedtotheredundantsystem,redundantarchitecturesareusedformoredemandingapplications:
• Remote I/O
• Distributed I/O
• MixedRIO/DIO
Automation Platforms selection guide
13.2.2.3 I/O architectures
The following two pages give an overview of I/O architectures. The list of modules that can be installed in a ModiconX80rackisprovidedinadedicatedsectionlaterinthisdocument.
(*)PTO,SSIencodersmodulesarenotsupportedinPESarchitectures(**)ManagementofHARTandAS-InterfaceinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjects Instantiation(1)BMEP58xx40CPUsarenotmandatory(2)BMXCRA31210modulesarealsocompatible
**
*
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.2.3 Modicon M580 processors
The following two pages give an overview of I/O architectures. The list of modules that can be installed in a ModiconX80rackisprovidedinadedicatedsectionlaterinthisdocument
(1)ThemaximumvaluesforthenumberofI/O,application-specificchannels,andthenumberofnetworksarenotcumulative(theyarelimitedbythe maximumnumberofslotsintheconfiguration,1rack:11,2racks:23,3racks:35,and4racks:47).(2)Dataandprogramshareamaximumof64MBmemorycapacity.4MBconfigurableretaineddatacanbesaveduponpowercycle.(*)Motioncontrol(PTO),SSIencoders,arenotsupportedinPESarchitectures(**)ManagementofHARTandAS-InterfaceinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjects Instantiation(***)controllerprogramwithLL984isnotsupportedinPESapplications
*
**
*
*
***
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.2.4 Communication, integrated ports and modules
(1)Fiberrequiresuseofotherproducts(forexample,anEthernetswitchortheBMXNRP020pmodule)toconvertfromthetwistedpairconnectors (RJ45)thattheseproductshave(2)ForBMx584040/5040/6040processors,RackViewerisnowavailable(*)UseonlyModbus/TCPforimplicitandexplicitmessaginginPESarchitectures
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(3)Including3connectionsreservedforPeer-to-Peercommunications(“localslaves”function)(*)UseonlyModbus/TCPforimplicitandexplicitmessaginginPESarchitectures(**)ManagementofcommunicationwiththeRTUmodulerequiresprogramminginrefinement
**
*
Automation Platforms selection guide
(4)Including16connectionsreservedforPeer-to-Peercommunications(“localslaves”function).(5)CANopencanbeused,butitisnecessarytouseModiconSTBI/O.Pleaseconsultthe“IP20distributedinputs/outputs–Modicon STB”catalogavailableonourwebsitewww.schneider-electric.com(*)ManagementofAS-InterfaceinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjects instantiation
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
13.3 Modicon Quantum automation platform
Limitations in support of architectures or hardware modules in the scope of application designed for Process ExpertSystemarchitecturesareidentifiedinthisdocumentwithan“(*)”inthemoduledescription,withanoteatthe bottom of the module description tables.
The last chapter of this section gives a summary of all unsupported modules for the automation platform.
13.3.1 Architectures
Different architecturesbasedontheQuantumautomationplatformarepossible,suchas:
• S908busforQuantumdrops
• EthernetRIOdropsandX80I/Oarchitectures,withorwithoutConneXiummanagedswitches
• Architectures with separate or combined Ethernet RIO and Ethernet DIO devices on the same physical medium
• HotStandby(HSBY)architectures
Automation Platforms selection guide
I/O ArchitecturesThe following two pages give an overview of I/O architectures. The list of modules that can be installed in a ModiconX80rackisprovidedinadedicatedsectionlaterinthisdocument.
(1) The maximum values for the number of discrete I/O and analog I/O are not cumulative(2)“Solutionmode”allowstimeanddate-stampedeventstobeformattedintheOPCFactoryserverwithouthavingtoprogramthecontroller(3)Updatedcertificationsshownonourwebsite:www.schneider-electric.com(4)Pleaserefertothespecificuserguidesuppliedwitheachproduct(5)ThemaximumnumberofNOMseriallinkmodulesislimitedto4perproject
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.3.2 Modicon Quantum processors
1) The maximum values for the number of discrete I/O and analog I/O are not cumulative(2)ProfibusDPmodulebyourTechnologyPartner,Prosoft(CollaborativeAutomationPartnerProgram)(3)ModbusPlusmodules:Onlythefirst2ofthe6modulesfeaturethefullrangeoffunctions(4)Max.distancebetweenthe2HotStandbyCPUs:upto4k(*)SingleslotCPUsshouldbeexceptionallyconsideredforPESapplicationsduetotheirlimitedcapabilities(**)Sercos,SymaxEthernet,andModbusPlusarenotsupportedinPESarchitectures(***)ManagementofAS-InterfaceinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjectsinstantiation(****)ProfibusmodulefromProsoftisnotknowninPES,butcanbeusedinprojectswithcomplementarydesigns
* *
****
******
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.3.3 Power supply modules
(1)OnlyConformalCoatingversions,dependingonthemodel,areATEXZone2/22certified
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.3.4 Discrete I/O modules: DC inputs
(1)Foronlinemodificationofconfiguration,refertothecatalog(2)ConnectionrequirestheModiconTelefastABE7pre-wiredsystem
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(3)OnlyConformalCoatingversions,dependingonthemodel,areATEXZone2/22certified
Automation Platforms selection guide
13.3.5 Discrete I/O modules: AC inputs
(1)Foronlinemodificationofconfiguration,refertothecatalog(2)OnlyConformalCoatingversions,dependingonthemodel,areATEXZone2/22certified
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.3.6 Discrete I/O modules: DC and relay outputs
(1)Foronlinemodificationofconfiguration,refertothecatalog(2)140DDO35300module:1.75+(0.4xtotalmoduleloadcurrent)inW140DDO35301module:5W,withalloutputsatstate1(3)Onlymodule140DDO35300isnon-interfering
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(4)ConnectionrequirestheModiconTelefastABE7pre-wiredsystem(5)OnlyConformalCoatingversions,dependingonthemodel,areATEXZone2/22certified
Automation Platforms selection guide
13.3.7 Discrete I/O modules: AC outputs
(1)Foronlinemodificationofconfiguration,refertothecatalog
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
(1)Foronlinemodificationofconfiguration,refertothecatalog
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(2)OnlyConformalCoatingversions,dependingonthemodel,areATEXZone2/22certified
Automation Platforms selection guide
13.3.8 Analog I/O modules: Current/voltage, temperature probe, thermocouple inputs
(1)Foronlinemodificationofconfiguration,refertothecatalog(2)Externalfusestobeusedonthe“MasterOverride”signalwhenitisconnectedtoanexternalsource
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(3)OnlyConformalCoatingversions,dependingonthemodel,areATEXZone2/22certified
Automation Platforms selection guide
13.3.9 Analog I/O modules: Current/voltage outputs, mixed I/O
(1)Foronlinemodificationofconfiguration,refertothecatalog(2)OnlyConformalCoatingversions,dependingonthemodel,areATEXZone2/22certified
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.3.10 Counter and special-purpose modules
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(*):140HLI34000moduleisnotsupportedinPESarchitecture
*
Automation Platforms selection guide
13.3.11 Networks and buses
(1) Only one Ethernet port can be used at a time(2)AutomaticassignmentofIPaddressandnetworkparameters(*):Ethernet/IPisnotsupportedinPESarchitectures(**)140NOC77101moduleisnotsupportedinPESarchitecture
**
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(*):140NWM10000moduleisnotsupportedinPESarchitecture
*
Automation Platforms selection guide
(*):140NOM2xx00and140EIA92100arenotsupportedinPESarchitecture
* *
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(*):140ESI06210isnotsupportedinPESarchitecture
*
Automation Platforms selection guide
13.3.12 EtherNet/IP and Modbus/TCP: Module communication capability and performance
Note:Theperformancecapacitylistedhereisaffectedbycertaintestconditionsincludinginput/outputsize,RPI(RequestPacketInterval),CPUscantimeCustomers may experience different results under different conditions(*)140NOC77101isnotsupportedinPESarchitecture(*)EtherNet/IP(CIPexplicitmessaging)isnotsupportedinPESarchitecture
*
*
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.4 Modicon M340 automation platform
Limitations in support of architectures or hardware modules in the scope of application designed for Process ExpertSystemarchitecturesareidentifiedinthisdocumentwithan“(*)”inthemoduledescription,withanoteatthe bottom of the module description tables.
The last section of this chapter provides a summary of all unsupported modules for the automation platform.
13.4.1 Architectures
DifferentarchitecturesbasedontheM340automationplatformarepossible,suchas:
• Multi-rackconfigurations
• EthernetX80I/Odrops
• Distributed I/Os
• Architectures with separate or combined Ethernet RIO and Ethernet DIO devices on the same physical medium
The following two pages give an overview of I/O architectures. The list of modules that can be installed in a ModiconX80rackisprovidedinadedicatedsectionlaterinthisdocument.
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(*):ThesemodulesarenotsupportedinPESarchitecture(**)ManagementofAS-InterfaceinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjectsinstantiation(***)Wi-FimoduleissupportedinPESarchitectures,butitisnotconfiguredinthePEStopology
*
*
**
***
*
Automation Platforms selection guide
13.4.2 Modicon M340 processors
(1)ThemaximumvaluesforthenumberofdiscreteI/O,analogI/O,counter/motioncontrol/seriallinkchannelsandthenumberofnetworksarenotcumulative(theyarelimitedbythemaximumnumberofslotsintheconfiguration,1rack:11;2racks:23;3racks:35;4racks:47(2)UserwebpageswithBMXNOE0110EthernetFactoryCastmodule(12MBavailable)(3)BMXP3420102/20102CL/20302/20302CLprocessorscanbeusedtocustomizeconfigurationofthedeviceBootUpprocedurecompatiblewithallCANopenthird-partyproducts(*)BMXMSP0200,BMXNOC0401arenotsupportedinPESarchitecture(*)CANopenbusisnotsupportedinPESarchitecture(**)BMXEIA0100(AS-Interface)issupported;managementofAS-InterfaceinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjectsinstantiation
*
*
*
**
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.4.3 Communication, integrated ports and modules
(*)CANopenbusisnotsupportedinPESarchitecture
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(*:)BMXNOC0401moduleisnotsupportedinPESarchitecture
*
Automation Platforms selection guide
(*)CANopenbusisnotsupportedinPESarchitecture(**)BMXEIA0100(AS-Interface)issupported,managementofAS-InterfaceinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjectsinstantiation
***
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.5 Modicon X80 I/O platform
13.5.1 Overview
The ModiconX80I/Oplatformservesasthecommonbaseforautomationplatformsbysimplyaddingadedicatedprocessor.Itmayalso:
• FormpartofaQuantumandModiconM580EthernetI/OarchitectureasanEthernetRIO(EIO)dropwitha CRA bus terminal module
• FormanEthernetModbus/TCPDIOdropwithaPRAmodule
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
13.5.2 Power supply modules
BMXCPSxxxxpowersupplymodulesprovidethepowersupplyforeachBMEXBPxx00orBMXXBPxx00ModiconX80I/Orackandthemodulesinstalledonit.
TheModiconX80I/Opowersupplymoduleoffercomprises:
• ThreepowersupplymodulesforDClinesupplies: >24Vcisolatedpowersupplymodule,BMXCPS2010 >24...48Vcisolatedpowersupplymodule,BMXCPS3020 >125Vcpowersupplymodule,BMXCPS3540T(extendedoperatingtemperature-25to+70°C/-13to +158°F)
• ThreepowersupplymodulesforAClinesupplies: >100...240Va,20Wpowersupplymodule,BMXCPS2000 >100...240Va,36Wpowersupplymodule,BMXCPS3500 >100...240Va,36Wredundantpowersupplymodule,BMXCPS4002
TheredundantACpowersupplycouldbeusedaloneinsinglepowersupplyrackordualpowersupplyrackasapair.Forhighavailableapplications,twoindependentredundantpowersuppliescouldbeusedtoincreasethesecurityofpowersupply.Incasethemasterpowersupplyfailstoprovidethewholecurrent,theslavepowersupply will change to master mode and continue to function.
Automation Platforms selection guide
13.5.3 Product compatibility according to the network architecture
(*)ManagementofHARTinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjectsinstantiation
**
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
(*)SSIencoder,PTO,weighing,EthernetBMXNOC,arenotsupportedinPESarchitecture(**)ManagementofAS-InterfaceinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjectsinstantiation(***)WirelessmodulecanbeusedinPESarchitectures,butthismoduleisnotconfiguredinthePES
**
*
**
***
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.5.4 Discrete I/O modules: Input modules
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.5.5 Discrete I/O modules: Input modules and mixed I/O modules
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.5.6 Discrete I/O modules: Output modules
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.5.7 Analog I/O modules: Input modules
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.5.8 Analog I/O modules: Output modules and mixed I/O modules
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.5.9 HART analog I/O modules
(*)ManagementofHARTinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjectsinstantiation
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.5.10 Communication, integrated ports and modules
(*)ManagementofcommunicationwiththeRTUmodulerequiresprogrammingrefinement
*
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
(*)ManagementofAS-InterfaceinPESapplicationsrequiresprogramminginadditiontothehardwareconfigurationandobjectsinstantiation
*
Automation Platforms selection guide
13.6 Modicon STB distributed I/O solution
TheModiconSTBdistributedI/Osolutionisanopen,modularinput/outputsystemthatmakesitpossibletodesignautomationislandsmanagedbyamastercontrollerviaabusorcommunicationnetwork.
Theseislandscanbeusedtoconnect:
• TeSys U or TeSys T starter-controllers
• Altivar variable speed drives
InadditiontodiscreteandanalogI/Os,applicationspecificI/OHARTchannelsareavailableintheislandwiththeHARTmultiplexermodule.
PESarchitecturessupportsModiconSTBdistributedI/OconnectedtoacontrollerthroughEthernetModBus/TCP.
OnlyAltivar31/61/71variablespeeddrivesandmotorcontroller/startersTeSysT/TeSysUcanbeconnectedthrough the local bus CANopen.
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
13.7 Profibus Remote Master
TheProfibusRemoteMaster(PRM)moduleisconnectedtotheEthernetModbusTCP/IPnetworkviaitsintegrated2-portswitch,ascloseaspossibletotheprocessandtheinstrumentation.ThePRMmodulecanbeusedtoconnectModiconQuantum,M580,andM340PLCstoProfibusDPV1viatheI/Oscannerfunction.IrrespectiveofthetypeofPLC,onlyoneproductreferenceisrequiredandthesetupisidentical.
Automation Platforms selection guide
13.8 Connection Interfaces
13.8.1 Modicon Telefast ABE7 pre-wired system discrete input and/or output sub-bases
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.8.2 Modicon Telefast ABE7 pre-wired system discrete input and output sub-bases
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.8.3 Modicon Telefast ABE7 pre-wired system analog and application-specific sub-bases
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Automation Platforms selection guide
13.9 List of unsupported modules in PES architectures
Thissectionsummarizesthelistofhardwaremodulesthatarenotsupportedorhavelimitedfunctionalitiesinthe context of applications designed with Process Expert System (PES).
13.9.1 M580 automation platform
AllmodulescompatiblewiththeM580automationplatform,includinginX80I/Oplatform,aresupportedexceptforthefollowingmodules:
Communicationmodules:• PMXNOW0300(Wi-Fiaccesspoint)–Itisignoredinthecontrollerconfiguration,butcanbeusedinPES architectures
Othermodulenotsupportedandnotmentionedinthisdocument:• BMXNOC0402(EthernetMB/TCP&IP)
Applicationspecificmodules:• BMXMSP0200(pulsetrainoutputs)• BMXEAE0300(SSIencoder)• PMESWT0100(Scaimepartnerweighingmodule)• BMXEIA0100(AS-IV3master)–CanbeconfiguredthroughPES,butmanagementofAS-Idevicesmust bedonebyprojectrefinement(noready-to-configureservicestomanagedevices)• BMEAHI0812&BMEAHO0412(HARTmodules)–TheyareconfiguredthroughPES,butrequireprogram refinementinadditiontothehardwareconfigurationandobjectsinstantiationtouseotherdatathanthe processvalue.RefertotheProcessExpertFoundationApplicationTemplatesUserGuide,chapter:"Using HartAnalogI/OSignalstoconfigurethemoduleswithfullfeatures".
13.9.2 Quantum automation platform
AllmodulesonQuantumEthernetRIOdroporQuantumS908RIOdroparecompatiblewiththeQuantumautomationplatform,exceptthefollowingmodules:
Communicationmodules:• 140NOC77101(EthernetIP)• 140NOM2xx00(ModbusPlus)• 140NWM10000(WebserverFactoryCast)• 140ESI06210(Asciiserialline)• 140EIA92100(AS-Imaster)
Othermodulesnotsupportedandnotdiscussedinthisdocument:• 140PTQPDPMV1(ProfibusmasterDPV1)–CanbeusedinaPESapplicationwithacomplementary designinsidethecontrolproject• 140NPP95400(fiberopticalrepeater)
INTRODUCTION
ARCHITECTURESOVERVIEW
UPDATING PES FROM V4.2 TO V4.3
TABLE OF CONTENTS
PROCESS EXPERT SYSTEM
KEY FEATURES
PROCESS EXPERT SYSTEM
CONFIGURATION: EXAMPLES
LIST OF REFERENCES
PROCESS EXPERT SYSTEM LIBRARIES
MANAGING LICENSES
HARDWARE REQUIREMENTS
TO RUN PROCESS EXPERT SYSTEM
SERVICE SUPPPORT ASSOCIATED WITH PROCESS EXPERT
SYSTEM
ORDERING PROCESS EXPERT
SYSTEM
INDUSTRIAL PC FOR PROCESS EXPERT SYSTEM
Automation Platforms selection guide
Applicationspecificmodules:• 140HLI34000(Highspeedinputs)
Othermodulesnotsupportedandnotdiscussedinthisdocument:• 140MSB10100(monoaxiswithencoder)• 140MSC10100(monoaxiswithresolver)• 140MMS42501(Sercos66Mhz)• 140MMS53502(Sercos133Mhz)
AllmodulescompatiblewiththeX80I/OplatformonQuantumaresupportedexceptthefollowingmodules:
Communicationmodules:• PMXNOW0300(Wi-Fiaccesspoint)–Itisignoredinthecontrollerconfiguration,butcanbeusedinPES architectures
Othermodulenotsupportedandnotdiscussedinthisdocument:• BMXNOC0402(EthernetMB/TCP&IP)
Applicationspecificmodules:• BMEAHI0812&BMEAHO0412(HARTmodules)–TheyareconfiguredthroughPES,butrequireprogram refinementinadditiontothehardwareconfigurationandobjectsinstantiationtouseotherdatathanthe processvalue.RefertotheProcessExpertFoundationApplicationTemplatesUserGuide,chapter:"Using HartAnalogI/OSignalstoconfigurethemoduleswithfullfeatures".
13.9.3 M340 automation platform
AllmodulescompatiblewiththeM340automationplatform,includinginanX80I/Oplatform,aresupportedexceptthefollowingmodules:
Communicationmodules:• BMXNOC0401/0401.2(EthernetMB/TCP&IP)• PMXNOW0300(Wi-Fiaccesspoint)–Itisignoredinthecontrollerconfiguration,butcanbeusedinPES architectures
Applicationspecificmodules:• BMXMSP0200(pulsetrainoutputs)• BMXEAE0300(SSIencoder)• BMXEIA0100(AS-IV3master)–CanbeconfiguredthroughPES,butmanagementofAS-Idevicesmust bedonebyprojectrefinement(noready-to-configureservicestomanagedevices)