procedure of connecting coil unit in series with capacitor

4
Procedure of Connecting Coil Unit In series with Capacitor 10 April 14 Product: Fully Automatic Washing Machine

Upload: senona

Post on 14-Jan-2016

25 views

Category:

Documents


1 download

DESCRIPTION

Product: Fully Automatic Washing Machine. 10 April 14. Procedure of Connecting Coil Unit In series with Capacitor. Procedure of Connecting Coil Unit In series with Capacitor. 10 April 14. Procedure : - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Procedure of Connecting  Coil Unit In series  with Capacitor

Procedure of Connecting Coil Unit In series

with Capacitor

10 April 14Product: Fully Automatic Washing Machine

Page 2: Procedure of Connecting  Coil Unit In series  with Capacitor

Procedure :

1. Remove the wire connector of Joint between

Capacitor Red Wire , Motor Red Wire & Harness Red

Wire .

2. Pick up the New Coil Unit . Do not Disassemble or

change the shape of Coil unit .

3. Connect the one end of Coil unit to Capacitor Red

Wire .

4. Crimp the wire connectors on wire joint between Coil

wire & Capacitor Red wire.

5. Connect another end of Coil unit to joint between

Red wire from Motor & Red wire from Harness .

6. Crimp the wire connectors on wire joint between Coil

wire , Red wire from Motor & Red wire from Harness .

7. After connecting Coil You have two separate joints of

Red coloured wires .before it was Single joint of red

wires as shown in photos.

Continue on next Page …

Procedure of Connecting Coil Unit In series with Capacitor

Applicable Models :

10 April 14

Joint 2 : Between Coil one end & Capacitor Red Wire

Joint 1 : Between Coil one end & Motor Red Wire & Harness Red wire

Present condition of machine : Single Joint between Capacitor Red Wire , Motor Red Wire , Harness Red Wire

After Coil Connect

VT 60H12VT 65H12VT 65E12VT 60A12VT 65G11VT 65B11KT6521

Page 3: Procedure of Connecting  Coil Unit In series  with Capacitor

Procedure :

8. Above Capacitor screwing hole there is a extra hole on cabinet

as marked in photo.

9. On Coil Unit there is a push mount present as marked in photo .

10. Fix this Push mount cable tie in holes present above the

Capacitor screwing hole .

Procedure of Connecting Coil Unit In series with Capacitor 10 April 14

Precautions :

1. Do not Disassemble or change the shape of Coil unit .

2. After attaching the coil please do proper harnessing of

all connectors.

Hole in to which Coil to be fixed from inner side of Cabinet with Push mount cable tie

Push Mount cable tie present on Coil Unit

Attached coil unit with cabinet with the help of push mount cable tie

After fixing Coil from inner side of cabinet

Page 4: Procedure of Connecting  Coil Unit In series  with Capacitor

Procedure of Connecting Coil Unit In series with Capacitor

FAWM Wiring Diagram for connections