Problem Report & Resolution Summary VEP, v1.1.7 Device = ADIS16228 PROBLEM The Alarm Status Form does not appear to detect Alarm conditions properly See Following slides for summary of observation RESOLUTION The process of observation omitted one critical step: enable alarms See pages 7 – 9 for stepbystep instructions on enabling the alarms. See page 13 for demonstration of expected results

Upload: others

Post on 15-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Problem Report & ResolutionSummary

• VEP, v1.1.7• Device = ADIS16228• PROBLEM

– The Alarm Status Form does not appear to detect Alarm conditions properly

– See Following slides for summary of observation• RESOLUTION

– The process of observation omitted one critical step: enable alarms

– See pages 7 – 9 for step‐by‐step instructions on enabling the alarms.

– See page 13 for demonstration of expected results  

Page 2: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #1 – Start the software

Page 3: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #2 – Press Start to run a Manual FFT capture, analysis and waveform update

Page 4: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #3 – Press Alarms > Alarm Settings to access the window to set the alarm levels

Page 5: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #4 – Press Read Default Values

Page 6: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #5 – Press Write to DUT, then exit Alarm Settings

Page 7: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #6 – Press Register Access from the Main Screen

Page 8: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #7 – Scroll down and find ALM_CTRL

Page 9: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #8 – Set ALM_CTRL[2:0] = 111Set New Hex Value to 87, then press Write

Page 10: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #9 – Exit Register AccessWindow, then Press Alarms > Alarm Status Form

Page 11: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #10 – Press > Start to run a Manual FFT

Page 12: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #11 – Change vertical scale in Waveform displays

Page 13: Problem Report Resolution Summary · 2013. 12. 16. · Problem Report & Resolution Summary • VEP, v1.1.7 • Device = ADIS16228 • PROBLEM – The Alarm Status Form does not appear

Step #12 – While shaking device, press > Start to run another Manual FFT