problem ho palsu

Upload: drio-rio

Post on 02-Jun-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/11/2019 Problem Ho Palsu

    1/3

    Wire Free Alliance > Discussions for Wireless Network > Live Optimization > Original Problem in HandoverPDAView Full Version : Original Problem in Handover

    haq_enam2011-04-13, 04:12 PMWe recently swap ericsson to Huawei and have not fimillier with parameters... One of the building we have done DT and found that outdoor(Serving) rxlevel is -95dBm and indoor(neigbor) is -65dBm but it should have oppsite. As indoor site inhigher priority that outdoor and clean frequency is used....

    I dont no any parameters that will help to solve the problems....It ishappeningonly dedicated mode but idel mode it is okey... Pls provide solution if u have..

    .DL PC is offRF engineer2011-04-13, 05:03 PMWe recently swap ericsson to Huawei and have not fimillier with parameters... One of the building we have done DT and found that outdoor(Serving) rxlevel is -95dBm and indoor(neigbor) is -65dBm but it should have oppsite. As indoor site inhigher priority that outdoor and clean frequency is used....

    I dont no any parameters that will help to solve the problems....It ishappeningonly dedicated mode but idel mode it is okey... Pls provide solution if u have...

    DL PC is off

    Dear

    In huawei the 1800 have higher priority ( layer 2) and 900 have (layer 3).What you have to check in system parameter called Cell layer if the are not as above changed , then you have another parameter to control HO between two band called inter-layer HO threshold if this parameter is put high value let say 45 it is better to change to 35 or less if you see still have good RF condition.

    BRhaq_enam2011-04-13, 06:07 PMDear

    In huawei the 1800 have higher priority ( layer 2) and 900 have (layer 3).What you have to check in system parameter called Cell layer if the are not as above changed , then you have another parameter to control HO between two band called inter-layer HO threshold if this parameter is put high value let say 45 it is better to change to 35 or less if you see still have good RF condition.

    BR

    Thanks for reply..

    Site is already layer 2 and inter-layer HO threshold is 25.

  • 8/11/2019 Problem Ho Palsu

    2/3

    Any other parameters to change or modifyRF engineer2011-04-13, 10:59 PMThanks for reply..

    Site is already layer 2 and inter-layer HO threshold is 25.

    Any other parameters to change or modify

    is it defined as neighbor.

    [email protected], 11:00 PMLayer Settings are correct and based on algorithm call should not be camped on outdoor 900 cell. Even if HO triggered due to Quality it should be on 2nd best cell. Can you check before HO trigger, what was the quality of connection and Check in L3 signalling msgs that prior HO in MR that MS sent to network what was the

    ranking of nbr cellsProbability of following parameter to be wrong is least but do check them

    1. Inter Layer HO Hysterysis should be around 42. BQ Margin set on relationship level default is 64 ( means 0 )normal range is68 ( 68- 4= 4 dB margin) setting high values of BQ margin on a specific relation makes it more favourable candidate in case of quality HO triggeredriyantoyadi2011-04-13, 11:07 PMwhat's BQ Margin set? please describre [email protected], 11:11 PM

    HW Parameter to Control the selection of candidate cell in case of urgency quality reason HO Triggeredriyantoyadi2011-04-13, 11:26 PMplease share to us any related document about this. We will very appreciatedhaq_enam2011-04-15, 12:26 AMis it defined as neighbor.

    BR

    Neighbor is defined.....it is not happening in all floorsriyantoyadi2011-04-15, 12:29 AMplease check this

    1. Power Control setting2. try to turn off PC on indoor buildingRF engineer2011-04-15, 02:16 PMNeighbor is defined.....it is not happening in all floors

    Dear

    The two snap is different in the first one the call in 900 and second one is on

    1800 so handover happen in the same floor? and the source cell and Neighbour are on the same BSC if not check External HO relation defined.

  • 8/11/2019 Problem Ho Palsu

    3/3

    What about the PBGT HO threshold and inter-cell HO hystersis and try to delete the neighbour and redefined again .

    BRhaq_enam2011-04-16, 12:48 PMplease check this

    1. Power Control setting2. try to turn off PC on indoor building

    U r asking dor both PC off...WE did UL PC ...haq_enam2011-04-16, 12:52 PMDear

    The two snap is different in the first one the call in 900 and second one is on1800 so handover happen in the same floor? and the source cell and Neighbour are

    on the same BSC if not check External HO relation defined.What about the PBGT HO threshold and inter-cell HO hystersis and try to delete the neighbour and redefined again .

    BR

    Both are in 4dB...HO between 900 and 1800....

    vBulletin v4.1.12, Copyright 2000-2014, Jelsoft Enterprises Ltd.