PRIMERGY TX150 S6 Server Options Guide Edition June 2009

Upload: others

Post on 11-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

PRIMERGY TX150 S6 Server Options Guide

Edition June 2009

Page 2: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to [email protected].

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2009 Fujitsu Technology Solutions GmbH.

All rights reserved.

Delivery subject to availability. The right to technical modification is reserved.

All hardware and software names used are trade names and/or trademarks of their respective manufacturers.

Page 3: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide

Contents

1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Concept and target groups . . . . . . . . . . . . . . . . . . . 7

1.2 Documentation overview . . . . . . . . . . . . . . . . . . . . 7

1.3 Expansions and conversions . . . . . . . . . . . . . . . . . . 9

1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 11

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 15

4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

4.1 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 214.1.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 214.1.2 Removing the front cover . . . . . . . . . . . . . . . . . . . . 224.1.3 Removing the hard disk cover . . . . . . . . . . . . . . . . . . 24

4.2 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 254.2.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 254.2.2 Removing the rack front cover . . . . . . . . . . . . . . . . . . 28

5 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 29

5.1 Equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . 29

5.2 Expanding/replacing the main memory . . . . . . . . . . . . 30

6 Accessible drives . . . . . . . . . . . . . . . . . . . . . . . 33

6.1 Installing an accessible 5.25-inch drive . . . . . . . . . . . . 34

6.2 Installing a 3.5-inch floppy disk drive . . . . . . . . . . . . . 37

6.3 Installing a hard disks extension box . . . . . . . . . . . . . 39

Page 4: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

Options Guide TX150 S6

Contents

6.4 Installing the multibay . . . . . . . . . . . . . . . . . . . . . . 46

7 ServerView Local Service Panel . . . . . . . . . . . . . . . . 49

7.1 Installing a LSP . . . . . . . . . . . . . . . . . . . . . . . . . 49

8 Expansion cards in the PCI slots . . . . . . . . . . . . . . . . 57

8.1 Installing an expansion card . . . . . . . . . . . . . . . . . . 58

8.2 PCI slot assembly . . . . . . . . . . . . . . . . . . . . . . . . 60

8.3 Installing a BBU . . . . . . . . . . . . . . . . . . . . . . . . . 61

9 SATA SW RAID . . . . . . . . . . . . . . . . . . . . . . . . . . 63

9.1 Inserting the RAID key . . . . . . . . . . . . . . . . . . . . . 63

10 External interfaces . . . . . . . . . . . . . . . . . . . . . . . 65

10.1 Installing the COM2 interface . . . . . . . . . . . . . . . . . . 65

10.2 Installing a parallel interface . . . . . . . . . . . . . . . . . . 66

11 Conversion standard PS to hot-plug PS . . . . . . . . . . . . 69

12 Conversion from a floorstand model to a rack model . . . . . 79

13 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

13.1 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 8513.1.1 Attaching the hard disk cover . . . . . . . . . . . . . . . . . . . 8513.1.2 Attaching the front cover . . . . . . . . . . . . . . . . . . . . . 8613.1.3 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . . 87

13.2 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 8813.2.1 Attaching the rack front cover . . . . . . . . . . . . . . . . . . . 8813.2.2 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . . 89

Page 5: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide

Contents

14 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

14.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

Page 6: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small
Page 7: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 7

1 PrefaceThe PRIMERGY TX150 S6 server is an Intel-based server for small and mid-size networks. The server is suitable for use as a file server and also as an appli-cation, information or Internet server. It is available as a floorstand or rack model. The floorstand model can be converted to a rack model using an optional conversion kit.

1.1 Concept and target groups

This Options Guide shows you how to extend and upgrade your server.

V CAUTION!

The activities described in this manual may only be performed by technical specialists.

I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server.

1.2 Documentation overview

More information on your PRIMERGY TX150 S6 can be found in the following documents:

– “Quick Start Hardware - PRIMERGY TX150 S6” leaflet (only included as a printed copy)

– “Quick Start Software - Quick Installation Guide” leaflet (only included as a printed copy)

– “Safety notes and other important information” manual

– “Warranty” manual

– “Customer Self Service (CSS)” manual

– “Ergonomics” manual

– “Returning used devices” manual

– “Helpdesk” leaflet

– Technical manual for the system board D2559

Page 8: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

8 Options Guide TX150 S6

Documentation overview Preface

– “PRIMERGY TX150 S6 Server Operating Manual”

– “PRIMERGY TX150 S6 Server Options Guide”

– “BIOS Setup V4.06 / FirstBIOS Desktop Pro V5.0 /TrustedCoreTM V6.0” manual

– “SAS/SATA Controller MegaRAID 1064 / 1068 / 1078 Installation Guide”

– “LSI SATA Software RAID User’s Guide”

– “LSI Logic MegaRAID SAS Software User’s Guide”

– “LSI Logic MegaRAID SAS Device Driver Installation” manual

– “Integrated RAID for SAS User’s Guide”

– “Embedded SATA Software RAID for ICH7R User’s Guide”

– “ServerView RAID User's Guide”

– “Integrated Mirroring User’s Guide”

I PRIMERGY manuals are available in PDF format on the ServerBooks DVD. The ServerBooks DVD is part of the ServerStart Suite supplied with every server.

The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL: http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option.

Further sources of information:

– Manual for the monitor– Documentation for boards and drives– Documentation for your operating system– Information files on your operating system

Page 9: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 9

Preface Expansions and conversions

1.3 Expansions and conversions

Main memory expansion

The system board supports up to 16 Gbyte main memory. 4 slots (2 memory banks with 2 slots each) are provided for the main memory. Each memory bank can be populated with 512 Mbyte, 1 Gbyte, 2 Gbyte or 4 Gbyte unbuffered DDR2 memory modules.

Accessible drives

Three 5.25-inch bays are available for accessible drives. In these bays you can install a DVD/DVD-RW drives, magnetic tape drives, a multibay (slimline DVD and FDD/ServerView Local Service Panel) or a hard disks extension box (only SAS base units). Below the 5.25-inch bays for accessible drives you will find also a bay for a 3.5-inch floppy disk drive.

Hard disks extension box

In the SAS base units two 5.25-inch bays for accessible drives can be used to install a hard disks extension box.

Two variants of the hard disks extension box are available:

– Variant 1:

one bay for a ServerView Local Service Panel, one bay for a slimline DVD drive and two bays for 3.5“ hard disks

– Variant 2 (special release required):

eight bays for 2.5“ hard disks

ServerView Local Service Panel

The system board supports the CSS (Customer Self Service) functionality (description see the operating manual). You can install a ServerView Local Service Panel for an easier identification of the defective components.

Page 10: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

10 Options Guide TX150 S6

Expansions and conversions Preface

Additional expansion cards in the PCI slots

The system board offers six PCI slots:

– 3 x PCI (32 Bit / 33 MHz)– 2 x PCI Express x8– 1 x PCI Express x4

SATA Software RAID

Only possible in SATA base units: the SATA SW RAID 5 functionality will be activated by installing a license key (RAID key).

COM2 interface

As an option, a second serial interface (COM2) can be provided.

Parallel interface for printers

As an option, a parallel interface can be provided for printers.

Conversion standard power supply to hot-plug power supply

The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of two power supply modules. The conversion kit contains only one power supply module, you have to order the second power supply separately.

If one power supply module fails, the other power supply module guarantees the unrestricted operation and the defective power supply module can be replaced be replaced while the system is operating (hot-plug).

Conversion from a floorstand model to a rack model

The floorstand model can be optionally converted to allow the server to be installed into any typical rack systems.

Page 11: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 11

Preface Notational conventions

1.4 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands or menu items.

“Quotation marks” indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Page 12: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small
Page 13: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 13

2 ProcedureV CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter-ference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Ê First of all, carefully read the safety instructions in the chapter “Safety instructions” on page 15 et seq..

Ê Make sure that all necessary manuals (see the section “Documentation overview” on page 7) are available; print the PDF files if required. Most importantly, you will need the operating manual for the server and the technical manual for the system board.

Ê Shut the server down correctly, switch it off, disconnect the power plugs and open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Carry out the expansion or upgrade of your server as described in the pertinent chapter.

I Installation and removal of the hot-plug components are described in the operating manual.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Ê Start the operating system and make the appropriate configuration if necessary (see the operating manual).

Page 14: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small
Page 15: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 15

3 Safety instructionsI The following safety instructions are also provided in the manual “Safety

notes and other important information”.

This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team.

V CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter-ference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Page 16: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

16 Options Guide TX150 S6

Safety instructions

Before starting up

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device.

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

Installation and operation

V CAUTION!

● This unit should not be operated in ambient temperatures above 35 °C.

● If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for type A connectors.

● The unit automatically adjusts itself to a mains voltage in a range of 100 V -240 V. Ensure that the local mains voltage lies within these limits.

● This device must only be connected to properly grounded shock-proof sockets or insulated sockets of the rack's internal power supply with tested and approved power cables.

● Ensure that the device is connected to a grounded shockproof socket close to the device.

Page 17: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 17

Safety instructions

V CAUTION!

● Ensure that the power sockets on the device and the grounded shock-proof sockets are freely accessible.

● The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the grounded shockproof sockets.

● Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage.

● Data cables must be adequately shielded.

● The EN 50173 and EN 50174-1/2 standards apply for LAN cabling. The minimum requirement is the use of a category 5 screened LAN cable for 10/100 Mbps Ethernet, or a category 5e cable for Gigabit Ethernet. The requirements from the ISO/IEC 11801 specification must also be met.

● Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual.

● Never connect or disconnect data transmission lines during a storm (risk of lightning strike).

● Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit).

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team.

Page 18: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

18 Options Guide TX150 S6

Safety instructions

V CAUTION!

● Proper operation of the system (in accordance with

IEC 60950-1/EN 60950-1) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expan-sions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet.

● The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: hot-plug power supply units/CCS components can be replaced.

● The warranty is void if the server is damaged during installation or replacement of system expansions.

● Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center.

Batteries

V CAUTION!

● Incorrect replacement of batteries may result in a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board).

● Replace the lithium-battery on the system board in accordance with the instructions in the technical manual for the system board.

Page 19: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 19

Safety instructions

Working with CDs/DVDs and CD/DVD drives

When working with devices with CD/DVD drives, these instructions must be followed.

V CAUTION!

● Only use CDs/DVDs that are in perfect condition in your server's CD/DVD drive, in order to prevent data loss, equipment damage and injury.

● Check each CD/DVD for damage, cracks, breakages etc. before inserting it in the drive.

Note that any additional labels applied may change the mechanical properties of a CD/DVD and cause imbalance.

Damaged and imbalanced CDs/DVDs can break at high drive speeds (data loss).

Under certain circumstances, sharp CD/DVD fragments can pierce the cover of the CD/DVD drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck).

I You can prevent mechanical damage and damage to the CD/DVD drive, as well as premature CD/DVD wear, by observing the following sugges-tions:

– Only insert CDs/DVDs in the drive when needed and remove them after use.

– Store the CDs/DVDs in suitable sleeves.– Protect the CDs/DVDs from exposure to heat and direct sunlight.

Laser information

The CD/DVD drive complies with IEC 60825-1 laser class 1.

V CAUTION!

The CD/DVD drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.

Never remove parts of the CD/DVD drive casing!

Page 20: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

20 Options Guide TX150 S6

Safety instructions

Modules with electrostatic-sensitive devices

Modules with electrostatic-sensitive devices are identified by the following sticker:

Figure 1: ESD label

When you handle components fitted with ESDs, you must always observe the following points:

● Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs.

● You must always discharge static build-up (e.g. by touching a grounded object) before working with such components.

● Any devices or tools that are used must be free of electrostatic charge.

● Wear a suitable grounding cable that connects you to the external chassis of the system unit.

● Always hold components with ESDs at the edges or at the points marked green (touch points).

● Do not touch any connectors or conduction paths on an ESD.

● Place all the components on a pad which is free of electrostatic charge.

I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

Page 21: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 21

4 PreparationV CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

4.1 Floorstand model

4.1.1 Opening the server

Ê Exit all applications and shut down the server properly.

Ê Press the On/Off button if the server has not been switched off by the operating system.

Ê Pull all power connectors out of the power outlets.

Ê If required, remove the lock on the side cover.

Figure 2: Removing the left-hand side cover

Ê Unlock the server (1).

Ê Loosen the two knurled screws at the rear side (2).

Ê Push back the left-hand side cover approxiate 2 cm (3).

Ê Remove the left-hand side cover (4).

1

3

2

4

Page 22: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

22 Options Guide TX150 S6

Floorstand model Preparation

4.1.2 Removing the front cover

Remove the front cover when making the following extensions and upgrades:

– Installation of further accessible drives– Conversion from a floorstand model to a rack model

Ê Remove the hard disk cover as shown in figure 6 on page 24.

Figure 3: Removing the front cover

Ê Disengage the three tabs (1-3) on the left side one after the other and rotate the front cover outward (4) about 2 cm.

Figure 4: Loosening the upper hook

Ê Push the drive cover downward (1).

Ê Press the touch point of the upper hook (2) inward.

1

4

2

3

1

2

Page 23: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 23

Preparation Floorstand model

Figure 5: Loosening the lower hooks

Ê Push the drive cover upward (1).

Ê Press the two touch points of the lower hooks (2+3) inward and pull out the front cover sideward (4).

2

3

41

Page 24: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

24 Options Guide TX150 S6

Floorstand model Preparation

4.1.3 Removing the hard disk cover

The hard disk cover has to be removed before installing further hard disk drives:

Ê Exit all applications and shut down the server properly.

Ê Press the On/Off button if the server has not been switched off by the operating system.

Figure 6: Removing the hard disk cover

Ê Unlock the server (1) and remove the key.

Ê Push the drive cover up as far as possible (2).

Ê Remove the hard disk cover (3 + 4).

1

2

3

4

Page 25: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 25

Preparation Rack model

4.2 Rack model

Ê Exit all applications and shut down the server properly.

Ê Press the On/Off button if the server has not been switched off by the operating system.

Ê Pull all power connectors out of the power outlets.

4.2.1 Opening the server

Figure 7: Loosening the knurled screws

Ê Loosen the four knurled screws (1) and pull the server as far as possible out of the rack (2).

1

2

Page 26: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

26 Options Guide TX150 S6

Rack model Preparation

Figure 8: Removing the server from the rack cabinet

Ê Disconnect all cables on the rear of the server.

Ê On the telescopic rails remove one screw on either side of the server (1).

Ê Release the locking mechanism (2a + 2b) of both rails and carefully pull the server out of the rack (3) as far as it will go.

Ê Pull the server a little in the direction marked (4a) until the noses (4b) disen-ngage.

V CAUTION!

At least two people are needed to lift the server out of the rack cabinet.

Ê Lift the server out of the rails (5) and place it on a table, for example.

1

2a

2b

4b

4a

3

5

Page 27: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 27

Preparation Rack model

Figure 9: Removing the top cover

Ê Unlock the top cover by removing the two screws on the server rear (1).

Ê Push the top cover to the rear approxiate 2 cm (2).

Ê Lift off the top cover upwards (3).

2

3

21

Page 28: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

28 Options Guide TX150 S6

Rack model Preparation

4.2.2 Removing the rack front cover

The rack front cover has to be removed before installing further accessible drives.

Figure 10: Removing the rack front cover

Ê Remove two knurled screws on either side (1).

Ê Remove the rack front cover to the front (2).

Figure 11: Removing the plastic front cover

Ê Disengage the three latches (1-3) on the top side one after the other and pull out the plastic front cover approxiate 2 cm (4).

Ê Press the three hooks (5-7) on the bottom side, carefully pull out on the plastic front cover and remove it to the front (8).

1

1

2

1

5

4

8

23

6

7

Page 29: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 29

5 Main memoryV CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

The system board supports up to 16 Gbyte main memory. 4 slots (2 memory banks with 2 slots each) are provided for the main memory. Each memory bank can be populated with 512 Mbyte, 1 Gbyte, 2 Gbyte or 4 Gbyte unbuffered DDR2 memory modules.

5.1 Equipping rules

Figure 12: Configuration of the main memory in memory banks and memory modules

– If the memory modules are installed in pairs, they must be identical (2-way interleaved mode).

– The memory module capacity can differ for the various memory banks: e.g. memory bank 2A/2B can be equipped with two 512 Mbyte memory modules, and memory bank 1A/1B with two 1 Gbyte memory modules.

DIMM 1A

DIMM 2A

DIMM 1B

DIMM 2B

Page 30: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

30 Options Guide TX150 S6

Expanding/replacing the main memory Main memory

The following table shows the prescribed equipping order:

I In case of dual channel configuration with four memory modules: all four memory slots must be equipped with identical memory modules.

5.2 Expanding/replacing the main memory

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Figure 13: Removing a memory module

Ê Fold the assembly brackets outwards on both sides of the corresponding slot (1).

Ê If the slot was equipped: pull the memory module out of the slot (2).

DIMM 1A DIMM 2A DIMM 1B DIMM 2B

single channel equipped empty empty empty

single/dual channel1

1 The dual-channel mode is only activated, if the size of the used memory modules in socket DIMM 2A is equal to the summary of memory modules in sockets DIMM 1A and DIMM 1B (e.g. DIMM 1A = 512 MB, DIMM 1 B= 512 MB, DIMM 2A = 1 GB).

equipped equipped equipped empty

dual channel equipped empty equipped empty

equipped equipped equipped equipped

1

1

2

Page 31: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 31

Main memory Expanding/replacing the main memory

Figure 14: Installing a memory module

Ê Fold the assembly brackets outwards on both sides of the corresponding slot.

Ê Carefully press the memory module into the slot (1) until the fastening tabs on both sides of it engage (2).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

2

2

1

Page 32: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small
Page 33: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 33

6 Accessible drivesV CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

Three 5.25-inch bays are available for accessible drives. In these bays you can install a DVD/DVD-RW drives, magnetic tape drives, a multibay (slimline DVD and FDD/ServerView Local Service Panel) or a hard disks extension box (only SAS base units). Below the 5.25-inch bays for accessible drives you will find also a bay for a 3.5-inch floppy disk drive.

Recommended equipping of the bays:

Figure 15: Recommended equipping of the bays

Page 34: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

34 Options Guide TX150 S6

Installing an accessible 5.25-inch drive Accessible drives

6.1 Installing an accessible 5.25-inch drive

Ê Open the server and remove the front cover or the rack front cover as described in the chapter “Preparation” on page 21 et seq..

I New 5.25-inch drives are supplied without EasyClick rails. Before installing a new drive you must therefore remove the EasyClick rails from the dummy cover and mount the EasyClick rails on the new drive.

Figure 16: Removing the dummy cover

Ê Press inward on the two metal tongues of the EasyClick rails (1) until the locking mechanism disengages.

Ê Remove the dummy cover from the mounting bay (2).

Figure 17: UNC and M3 screws

Ê Detach the EasyClick rails from the dummy cover by removing the four screws on each side.

I Note that there are two M3 screws and two UNC screws on each side.

1

1

2

M3 screw

(small screw head)

UNC screw

(large screw head)

Page 35: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 35

Accessible drives Installing an accessible 5.25-inch drive

V CAUTION!

Keep the dummy cover in a safe place. If you remove the accessible drive again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling require-ments and fire protection measures.

Figure 18: Attaching the EasyClick rails - DVD drive

Ê Screw the EasyClick rails onto either side of the new 5.25-inch drive using two M3x4.5mm screws (1).

Use the first hole in each upper row of holes as shown in the figure.

I Keep the remaining screws for future use. The different drives are fastened using different screws. Starting on the next page, you will find figures which show the attaching of the EasyClick rails for magnetic tape drives.

Ê Push the new drive about halfway into the bay.

Ê Connect the data cable to the accessible drive (see the cabling plans in the Appendix).

Ê Connect the power cable to the accessible drive (see the cabling plans in the Appendix).

Ê Push the drive fully into the bay until the EasyClick rails lock in place.

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

1

1

Page 36: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

36 Options Guide TX150 S6

Installing an accessible 5.25-inch drive Accessible drives

You will find in the following figures which holes and screws should be used for the magnetic tape dives.

Figure 19: Attaching the EasyClick rails - tape drives LTO Ultrium 2HH / 3FH

Figure 20: Attaching the EasyClick rails - tape drives VXA-2 and DDS Gen5

Page 37: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 37

Accessible drives Installing a 3.5-inch floppy disk drive

6.2 Installing a 3.5-inch floppy disk drive

The 3.5-inch bay for the optional floppy disk drive is positioned between the hard disks cage and the 5.25-inch bays for accessible drives.

Ê Open the server and remove the front cover or the rack front cover as described in the chapter “Preparation” on page 21 et seq..

Ê From the inside press out the 3.5-inch dummy cover on the front cover.

V CAUTION!

Keep the dummy cover in a safe place. If you remove the accessible drive again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling require-ments and fire protection measures.

Figure 21: Removing the floppy disk drive holder

Ê Remove the two screws (1) that attach the drive holder to the housing front.

Ê Pull on the drive holder and completely remove it from the server (2).

1

2

Page 38: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

38 Options Guide TX150 S6

Installing a 3.5-inch floppy disk drive Accessible drives

Figure 22: Installing the floppy disk drive in the drive holder

Ê Position the new floppy disk drive in the drive holder (1) and fasten it with two screws on each side (2).

Figure 23: Mounting the floppy disk drive holder

Ê Push the drive holder and floppy disk drive fully into the mounting bay (1).

Ê Fasten the drive holder to the housing with two screws (2).

Ê Connect the data cable to the floppy disk drive (see the cabling plans in the Appendix).

Ê Connect the power cable to the floppy disk drive (see the cabling plans in the Appendix).

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

2

2

1

1

2

Page 39: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 39

Accessible drives Installing a hard disks extension box

6.3 Installing a hard disks extension box

In the SAS base units two 5.25-inch bays for accessible drives can be used to install a hard disks extension box.

Two variants of the hard disks extension box are available:– Variant 1:

one bay for a ServerView Local Service Panel, one bay for a slimline DVD drive and two bays for 3.5“ hard disks

– Variant 2 (special release required):eight bays for 2.5“ hard disks

If the server has a RAID controller and a corresponding RAID configuration, defective HDD modules can also be exchanged during operation (hot-plug).

Ê Open the server and remove the front cover or the rack front cover as described in the chapter “Preparation” on page 21 et seq..

I The hard disks extension box is supplied without EasyClick rails. You need 4 M3 screws. Before installing a new hard disks extension box you must therefore remove the EasyClick rails from one dummy cover and mount two EasyClick rails on the hard disks extension box.

Ê Remove the dummy covers from the two lower 5.25-inch bays for accessible drives:

Ê Press inward on the two metal tongues of the EasyClick rails until the locking mechanism disengages.

Ê Remove the dummy cover from the bay.

Ê Remove the EasyClick rails from the two dummy covers by removing the four screws on each side.

I Note that there are two M3 screws and two UNC screws on each side.

V CAUTION!

Keep the dummy covers for future use. If you remove the hard disks extension box again and do not replace it with new drives, the dummy covers must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 40: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

40 Options Guide TX150 S6

Installing a hard disks extension box Accessible drives

Variant 1

Figure 24: Variant 1 - Attaching the EasyClick rails

Ê Screw the EasyClick rails onto either side of the hard disks extension box using two M3 screws for each rail. Use the holes marked above (see the circles) for this purpose.

Install possibly a slimline DVD drive:

Ê Release the DVD dummy by pressing the touch point upward (see arrow in figure 24).

Ê Push the DVD dummy out of the bay in direction of the front side.

Page 41: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 41

Accessible drives Installing a hard disks extension box

Figure 25: Taking out the dummy

Ê Take the dummy out of the frame by extracting sideward the frame until the four noses of the frame disengage.

V CAUTION!

Keep the dummy for future use. If you remove the slimline drive again and do not replace it with a new one, the dummy must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Figure 26: Inserting the slimline DVD in the frame

Ê Insert the slimline DVD drive in the frame. The four noses will fasten the frame.

Page 42: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

42 Options Guide TX150 S6

Installing a hard disks extension box Accessible drives

Figure 27: Slimline DVD with cables

Ê Connect the SATA cable and the PS adapter cable to the rear side of the slimline DVD drive (see the cabling plans in the Appendix).

Ê Slide the slimline DVD drive into the bay in the hard disks extension box until it latches in place. Take care that the cables do not clamp.

Ê Push the hard disks extension box fully into the bay until the EasyClick rails lock in place.

Ê Connect the power cable plug P4 to the PS adapter cable of the slimline DVD drive (see the cabling plans in the Appendix).

Ê Route the SATA cable of the slimline DVD drive and connect it to the SATA connector SATA5 on the system board (see Technical Manual for the system board D2559).

Page 43: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 43

Accessible drives Installing a hard disks extension box

Figure 28: Variant 1 - Connectors of the HDD backplane

Ê Connect the power cable plug P2 to the power connector of the HDD backplane on the rear side of the hard disks extension box.

Ê Connect the SAS cable included in the conversion kit to the SAS connector on the HDD backplane.

Ê Connect the I2C cable with the I2C bus connector on the HDD backplane (see the cabling plans in the Appendix).

Ê Secure the I2C cable with a green clamp.

Ê Route the SAS cable and connect it to the connector of an additional SATA RAID controller (see the cabling plans in the Appendix).

Ê Install the 3.5“ hard disks (description see the Operating Manual).

Ê Possibly install a ServerView Local Service Panel (description see chapter “ServerView Local Service Panel” on page 49).

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Power/

Strom

SASI2C

Page 44: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

44 Options Guide TX150 S6

Installing a hard disks extension box Accessible drives

Variant 2

Figure 29: Variant 2 - Attaching the EasyClick rails

Ê Screw the EasyClick rails onto either side of the hard disks extension box using three M3 screws for each rail. Use the holes marked above for this purpose.

Ê Push the hard disks extension box fully into the bay until the EasyClick rails lock in place.

Page 45: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 45

Accessible drives Installing a hard disks extension box

Figure 30: Variant 2 - Connectors of the HDD backplane

Ê Connect the PS adapter cable to the power connectors of the HDD backplanes on the rear side of the hard disks extension box.

Ê Connect the power cable plug P2 to the PS adapter cable.

Ê Connect the SAS cables included in the conversion kit to the SAS connectors on the HDD backplanes.

Ê Route the SAS cables and connect them to the connectors of an additional SATA RAID controller (see the cabling plans in the Appendix).

Ê Install the 2.5“ hard disks (description see the Operating Manual).

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

power

SAS

Page 46: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

46 Options Guide TX150 S6

Installing the multibay Accessible drives

6.4 Installing the multibay

Ê Open the server and remove the front cover or the rack front cover as described in the chapter “Preparation” on page 21 et seq..

Ê Remove the dummy cover from one 5.25-inch bay for accessible drives:

Ê Press inward on the two metal tongues of the EasyClick rails until the locking mechanism disengages.

Ê Remove the dummy cover from the bay.

Figure 31: Removing the DVD dummy from the multibay

Ê Release the DVD dummy by pressing the touch point upward (see arrow in figure 31).

Ê Push the DVD dummy out of the bay in direction of the front side.

Ê Take the dummy out of the frame by extracting sideward the frame until the four noses of the frame disengage (see figure 25 on page 41).

Page 47: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 47

Accessible drives Installing the multibay

V CAUTION!

Keep the dummy for future use. If you remove the slimline drive again and do not replace it with a new one, the dummy must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Ê Insert the slimline DVD drive in the frame. The four noses will fasten the frame (see figure 26 on page 41).

Figure 32: Inserting slimline DVD drive in multibay

Ê Push the slimline DVD drive into the multibay until it latches in place.

Ê Connect the SATA cable and the PS adapter cable to the rear side of the slimline DVD drive (see figure 27 on page 42 and the cabling plans in the Appendix).

Ê Push the multibay fully into the bay until the EasyClick rails lock in place. Take care that the cables do not clamp.

Ê Connect the power cable plug P4 to the PS adapter cable of the slimline DVD drive (see the cabling plans in the Appendix).

Ê Route the SATA cable of the slimline DVD drive and connect it to the SATA connector SATA5 on the system board (see Technical Manual for the system board D2559).

Page 48: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

48 Options Guide TX150 S6

Installing the multibay Accessible drives

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 49: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 49

7 ServerView Local Service PanelV CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

It is possible to install a ServerView Local Service Panel (LSP) in the bay at the top of the hard disks extension box for 3.5“ hard disks or in the lower bay of the multibay.

7.1 Installing a LSP

Installing in a hard disks extension box

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Disconnect all cables at the rear side of the hard disks extension box. Notice the cabling.

Ê Press inward on the two metal tongues of the EasyClick rails until the locking mechanism disengages.

Ê Remove the hard disks extension box from the bay.

Page 50: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

50 Options Guide TX150 S6

Installing a LSP ServerView Local Service Panel

Figure 33: Removing the dummy cover

Ê Press the locking bar of the dummy cover inward and push the dummy cover out of the bay frontward.

V CAUTION!

Keep the dummy cover in a safe place. If you remove the ServerView Local Service Panel again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 51: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 51

ServerView Local Service Panel Installing a LSP

Figure 34: Installing the ServerView Local Service Panel

Ê Push the ServerView Local Service Panel from the front side into the bay.

Ê Push the hard disks extension box fully into the bay until the EasyClick rails lock in place.

Ê Connect all cables to the rear side of the hard disks extension box (see the cabling plans in the Appendix).

Ê Connect the data cable with the ServerView Local Service Panel and the connector X3 in the operating panel module (see the cabling plans in the Appendix).

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 52: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

52 Options Guide TX150 S6

Installing a LSP ServerView Local Service Panel

Installing in multibay

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Disconnect all cables at the rear side of the multibay. Notice the cabling.

Ê Press inward on the two metal tongues of the EasyClick rails until the locking mechanism disengages.

Ê Remove the multibay from the bay.

Figure 35: Removing the dummy cover

Ê Push the dummy cover from the inside out of the bay frontward.

V CAUTION!

Keep the dummy cover in a safe place. If you remove the ServerView Local Service Panel again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 53: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 53

ServerView Local Service Panel Installing a LSP

Figure 36: ServerView Local Service Panel frame

Figure 37: Inserting the ServerView Local Service Panel in the frame

Ê Push the ServerView Local Service Panel from the front side into the frame.

Ê Detach the EasyClick rails from the multibay by removing the two screws on each side.

Page 54: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

54 Options Guide TX150 S6

Installing a LSP ServerView Local Service Panel

Figure 38: Inserting the ServerView Local Service Panel in the multibay

Ê Push the ServerView Local Service Panel from the rear side into the multibay.

Ê Fasten the ServerView Local Service Panel with two screws on each side to the multibay.

Figure 39: ServerView Local Service Panel in Multibay

Ê Screw the EasyClick rails onto either side of the multibay using two screws

Ê Push the multibay fully into the bay until the EasyClick rails lock in place.

Page 55: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 55

ServerView Local Service Panel Installing a LSP

Ê Connect all cables to the rear side of the multibay (see the cabling plans in the Appendix).

Ê Connect the data cable with the ServerView Local Service Panel and the connector X3 in the operating panel module (see the cabling plans in the Appendix).

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 56: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small
Page 57: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 57

8 Expansion cards in the PCI slotsV CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

The system board offers six PCI slots:

Figure 40: Numbering of the PCI slots

I For more information see the Technical Manual of the system board D2559.

PCI slot 64Bit/32Bit

Frequency in MHz

Voltage Description

1 32 Bit 33 5 32-Bit PCI bus slot

2 32 Bit 33 5 32-Bit PCI bus slot

3 32 Bit 33 5 32-Bit PCI bus slot

4 PCIe x4 bus slot

5 PCIe x8 bus slot

6 PCIe x8 bus slot

1

2

3

4

5

Slot 3

Slot 2

Slot 1

Slot 4

Slot 5

Slot 6

PCIe x8

PCI 32 Bit / 33 MHz

PCIe x8 6

PCI 32 Bit / 33 MHz

PCI 32 Bit / 33 MHz

PCIe x4

Page 58: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

58 Options Guide TX150 S6

Installing an expansion card Expansion cards in the PCI slots

8.1 Installing an expansion card

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Figure 41: Removing the rear cover

Ê Swing the locking swivel in the direction of the arrow (1).

Ê Press onto the clip (2) and remove it.

Ê Remove the PCI slot cover (3).

V CAUTION!

Keep the rear cover of the PCI slot for future use. If you remove the expansion card again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

1

2

3

Page 59: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 59

Expansion cards in the PCI slots Installing an expansion card

Figure 42: Installing an expansion card

Ê Install the expansion card in the PCI slot and press it carefully into the associated plug-in location on the system board (1) until it engages properly.

Ê Place the clip on the slot cover in such a way that the pin (a) fits into the hole of the slot cover (2), and press the clip in the direction of the arrow (3) until it engages.

Ê Swing the lever (4) in its locking position.

Ê If necessary, connect the cables to the expansion card and the other compo-nents.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

1

2

34

a

Page 60: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

60 Options Guide TX150 S6

PCI slot assembly Expansion cards in the PCI slots

8.2 PCI slot assembly

Slot 5 (PCIe) is the default slot for the boot controller. If the boot controller should be operated in an other PCIe slot, it is necessary to set the PCI scan for this slot to "enabled" and the PCI scan for slot 5 to "disabled" in the BIOS.

The controllers LSI MegaRAID SAS 8308ELP and LSI MegaRAID SAS 8344ELP are released only for slot 6.

Otherwise install PCI cards in the PCI slots 1-3 and PCIe cards in the PCIe slots 4-6.

Page 61: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 61

Expansion cards in the PCI slots Installing a BBU

8.3 Installing a BBU

You can install up to two Battery Backup Units (BBU).

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Figure 43: Connecting the cable to the BBU

Ê Connect the cable to the BBU.

V CAUTION!

Make sure that the connector side with two pin rows is on the top. Otherwise you risk short-circuits.

Side with one pin row: Side with two pin rows:

Page 62: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

62 Options Guide TX150 S6

Installing a BBU Expansion cards in the PCI slots

Figure 44: Position screws

Ê Lay the server on the side.

Ê Position the BBU on the inner side of the housing bottom (the first BBU in the front range, a second BBU in the middle range).

Ê Fasten the BBU with three screws at the outer side.

Figure 45: Installed BBU

Ê Connect the cable to the expansion card.

V CAUTION!

Make sure that the connector side with two pin rows is on the top. Otherwise you risk short-circuits.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

BBU 1BBU 2

Page 63: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 63

9 SATA SW RAIDV CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

The SATA SW RAID 5 functionality will be activated by installing a license key (RAID key).

9.1 Inserting the RAID key

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Figure 46: Inserting the RAID key

Ê Insert the RAID key in the round socket on the system board (see Technical Manual for the system board D2559).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 64: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small
Page 65: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 65

10 External interfacesV CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

10.1 Installing the COM2 interface

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Figure 47: COM2 interface

Ê Remove the rear cover of PCI slot 7 and insert the slot cover of the COM2 interface in this slot as described in section “Installing an expansion card” on page 58.

Ê Attach the connector Serial2 on the system board with the COM2 interface connector.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 66: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

66 Options Guide TX150 S6

Installing a parallel interface External interfaces

10.2 Installing a parallel interface

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Figure 48: Removing the system fan holder

Ê Disconnect the system fan cable from the connector FAN1 SYS on the system board (see circle).

Ê Press on the green lock bar of the system fan holder in direction of the arrow and remove the holder.

Page 67: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 67

External interfaces Installing a parallel interface

Figure 49: Breaking off the interface plate

Ê Break off the interface plate using a screwdriver.

Figure 50: Fastening the plug connector at the rear of the housing

Ê Feed the plug connector through the notch at the rear of the housing.

Ê Fasten the plug connector to the rear of the housing using the threaded bolts supplied (see arrows).

Page 68: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

68 Options Guide TX150 S6

Installing a parallel interface External interfaces

Figure 51: Routing the cable

Ê Route the cable as shown in the photo.

Ê Connect the cable’s connector to the parallel port connector on the system board.

Ê Reinstall the system fan holder. The proper holder position can best be judged from the outside at the rear side of the server. When doing so, make sure the holder lock bar engages properly.

Ê Connect the fan cable to the connector FAN1 SYS on the system board.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 69: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 69

11 Conversion standard PS to hot-plug PS

V CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of up to two power supply modules. The upgrade kit contains only one power supply module (for power supply redundancy the second power supply module must be additionally ordered).

The upgrade kit for the hot-plug power supply consists of the following parts:

– PS cage with Power backplane (incl.power cables)

– locking rail

– one power supply unit

– dummy cover (if only one power supply module is installed, you have to install the dummy cover in the second bay)

– several screws

– anti-tilt bracket

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Disconnect all power cables from the system board and the drives (see the cabling plans in the Appendix).

Page 70: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

70 Options Guide TX150 S6

Conversion standard PS to hot-plug PS

Figure 52: Loosening the screws

Ê Remove the five screws (1) which attach the adapter plate of the standard power supply to the housing.

Figure 53: Taking out the standard power supply

Ê Slide the standard power supply somewhat toward the inside (1) to detach it from the brackets in the side cover and take it out toward the side (2).

11

2

1

Page 71: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 71

Conversion standard PS to hot-plug PS

Figure 54: Installing the Power backplane in the PS cage

Ê Insert the Power backplane in the PS cage.

Ê Push the Power backplane in direction of the arrows until the three bolts of the PS cage engage.

Ê Fasten the Power backplane with one knurled screw (see the circle).

Page 72: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

72 Options Guide TX150 S6

Conversion standard PS to hot-plug PS

Figure 55: Installing the PS cage

Ê Push the PS cage from inside into the bay. In the floorstand model the Power backplane is positioned under the top cover, and in the rack model at the right-hand side cover (seen from front side).

V CAUTION!

Make sure that the two noses of the PS cage (see the arrows) engage in the housing. Ensure that no damage is caused to the cables.

Page 73: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 73

Conversion standard PS to hot-plug PS

Figure 56: Fastening the PS cage in the housing

Ê Fasten the PS cage in the housing with one screw M3x4.5 mm (see the circle).

Figure 57: Fastening the PS cage at the rear side

Ê Fix the locking rail with four screws (see the arrows) on the rear side of the server.

Ê Fasten the PS cage with three screws M3x4.5 mm (see the circles) at the rear side.

Ê Disconnect all power cables from the system board and the drives (see the cabling plans in the Appendix).

Page 74: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

74 Options Guide TX150 S6

Conversion standard PS to hot-plug PS

Figure 58: Inserting the power supply module

Ê Push the power supply module in the left side (floorstand model) or bottom side (rack model) bay.

Ê Lift the green handle somewhat upwards so that the forked levers (see the arrows) can fit to the locking rail.

Page 75: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 75

Conversion standard PS to hot-plug PS

Figure 59: Locking the power supply module

Ê Push the green handle downward until the locking slide (see the arrow) engages.

Ê Plug the power cord to the connector of the power supply module.

Ê If you want to install a second power supply module, proceed in the same way.

Page 76: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

76 Options Guide TX150 S6

Conversion standard PS to hot-plug PS

Figure 60: Installing the dummy cover

Ê If you have not ordered a second power supply module, install the dummy cover in the second bay:

Hook the top side of the dummy cover into the chassis, after this swivel the dummy cover down and fasten it with one screw (see the arrow) to the housing.

V CAUTION!

For floorstand models with hot-plug power supply the supplied anti-tilt bracket must be fitted at the rear of the server.

Page 77: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 77

Conversion standard PS to hot-plug PS

Mounting the anti-tilt bracket (only floorstand model)

Ê Attach the left-hand side cover as described in section “Closing the server” on page 87.

Figure 61: Mounting the anti-tilt bracket

Ê Position the server on the anti-tilt bracket in the way that the rubber feet of the server fit into the openings of the bracket (1).

1

1

Page 78: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

78 Options Guide TX150 S6

Conversion standard PS to hot-plug PS

Figure 62: Fastening the anti-tilt bracket

Ê Fasten the anti-tilt bracket using the two knurled screws (1).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

V CAUTION!

After installing the hot-plug power supply a fan calibration must be started. You will find the description for this procedure in the manual “ServerStart“.

I You will find the description of the indicators of the power supply module in the Operating Manual.

1

1

Page 79: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 79

12 Conversion from a floorstand model to a rack model

V CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

Ê Open the server and remove the front cover as described in the chapter “Preparation” on page 21et seq..

I The front cover is no longer required.

Figure 63: Removing the stabilizer

Ê If your server is equipped with an anti-tilt bracket, remove it:

Ê Remove the two knurled screws (1) and lift the server out of the anti-tilt bracket.

The right-hand side cover and the top cover build one part.

1

1

Page 80: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

80 Options Guide TX150 S6

Conversion from a floorstand model to a rack model

Figure 64: Removing the screws

Ê Remove the two screws at the rear side.

Figure 65: Removing the right-hand side cover

Ê Lift the hook up slightly using a screwdriver.

Ê Push the right-hand side cover in the direction of the arrow.

Ê Lift off the right-hand side cover.

I The right-hand side cover is no longer required.

Page 81: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 81

Conversion from a floorstand model to a rack model

Ê Lay the server on its right-hand side.

V CAUTION!

Get a second person to help you do this. The server can weigh up to 40 kg.

Figure 66: Removing the rubber feet

Ê Remove the three screws (see the circles) and take out the rail with the two lower rubber feet.

I The rubber feet and the rail are no longer required.

Page 82: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

82 Options Guide TX150 S6

Conversion from a floorstand model to a rack model

The drive cage for the accessible drives is constructed in such a way that the accessible drives and the operating panel module can be taken out simply, turned through 90° to the left, and then be reinstalled.

Ê Remove the dummy covers from the drive cage (figure 16 on page 34).

Ê Unplug the cables from the system board or the accessible drives and remove the drives from the drive cage.

Ê Pull the operating panel module forward out of its mounting location until you can pull the ribbon cable and the USB cable out of the operating panel module. Remove the two cables.

Ê Remove the operating panel module.

Ê Turn the operating panel module through 90° to the left.

Figure 67: Installing the operating panel module

Ê Push the operating panel module halfway into the upper bay of the drive cage.

Ê Connect the ribbon cable and the USB cable to the operating panel module.

Ê Now push the operating panel module fully into the upper bay of the drive cage.

Ê Turn the drives removed beforehand through 90° to the left.

Ê Turn the dummy covers removed beforehand through 90° to the left.

Ê Install the drives and empty covers in the drive cage.

Ê Reestablish all connections to the drives.

Page 83: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 83

Conversion from a floorstand model to a rack model

Ê Attach the rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85et seq..

To enable the rack model to be presented correctly in ServerView, proceed as follows:

Ê Place the ServerStart CD-ROM CD1 in the drive.

Ê Select “Tools - System Configuration Utilities - SCU Chassis Model Conversion“ and convert the server type to rack mounted.

Page 84: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small
Page 85: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 85

13 CompletionV CAUTION!

Follow the safety instructions in the chapter “Safety instructions” on page 15 et seq..

13.1 Floorstand model

13.1.1 Attaching the hard disk cover

After you have installed further hard disk drives, reattach the hard disk cover.

Figure 68: Attaching the hard disk cover

Ê Push the drive cover up as far as possible (1).

Ê Reinsert the hard disk cover (2 + 3).

Ê Insert the key.

Ê Lock the server.

Ê Press the on/off key to start up the server.

12

3

Page 86: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

86 Options Guide TX150 S6

Floorstand model Completion

13.1.2 Attaching the front cover

After you have installed further accessible drives, reattach the front cover.

Figure 69: Attaching the front cover

Ê Press the three hooks (1) on the right side in the recesses of the housing.

Ê Press the front cover onto the housing (2) until the three tabs on the left side engage (3).

Ê Attach the hard disk cover as shown in figure 68 on page 85.

1

3

2

Page 87: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 87

Completion Floorstand model

13.1.3 Closing the server

Figure 70: Attaching the left-hand side cover

Ê Position the left-hand side cover in such a way that it protrudes approxiate 2 cm at the rear (1). Shut the left-hand side cover.

Ê Push the left-hand side cover all the way forward (2).

Figure 71: Fastening the left-hand side cover

Ê Fasten the left-hand side cover with two screws (1).

Ê Insert the key.

Ê Lock the server.

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

12

1

Page 88: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

88 Options Guide TX150 S6

Rack model Completion

13.2 Rack model

13.2.1 Attaching the rack front cover

Reattach the rack front cover after implementing the following extensions:

– Installation of further accessible drives

– Conversion from a floorstand model to a rack model

Figure 72: Attaching the plastic front cover

Ê Press the three hooks (1) on the bottom side in the recesses of the housing.

Ê Press the plastic front cover onto the housing (2) until the three tabs on the top side engage (3).

3

1

2

Page 89: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 89

Completion Rack model

Figure 73: Attaching the rack front cover

Ê Attach the rack front cover from the front (1).

Ê Attach the rack front cover using two screws on each side (2).

13.2.2 Closing the server

Figure 74: Mounting the top cover

Ê Position the top cover in such a way that it protrudes approxiate 2 cm at the rear (1).

2

2

1

3

2

1

Page 90: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

90 Options Guide TX150 S6

Rack model Completion

Ê Push the top cover all the way forward (2).

Ê Fasten the top cover with two screws (3).

If you have not removed the server from the rack cabinet, please skip this page.

V CAUTION!

At least two people are required to install the server in the rack cabinet.

Do not use the handles on the rack front cover to lift the server into the rack.

Ê Pull the mounted telescopic rails completely out toward the front. They must click into place so that you can no longer push them back.

Figure 75: Installing the server in a rack cabinet

Ê Lift the server onto the two projecting telescopic rails (1).

V CAUTION!

Never lift or transport the server using the handles on the front panel.

Ê Slide the server a little in the direction marked (2a) until the noses (2b) engage. When doing this, ensure that the telescopic rails are kept in a locked position.

3

4a

4b

2b

2a

5

1

Page 91: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 91

Completion Rack model

Ê Secure the server to the telescopic rails using two M3x6 screws for each side one (3).

The following steps can then be carried out by one person only.

Ê Release the locking mechanism of both rails (4a + 4b) and insert the server completely into the rack (5).

Figure 76: Fastening the server in the rack cabinet

Ê Place the cage nuts for fastening the front panel in the corresponding holes of the front support uprights and fasten the server using four knurled screws.

Ê Route the cables with the inserted server as described in the Technical Manual of the corresponding rack.

Page 92: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small
Page 93: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 93

14 Appendix

14.1 Cabling

Figure 77: Cabling - standard PS, 3.5“ hard disks

Ca

ble

pre

fix: T

26

13

9-

Pow

er

SA

TA

IDE

/FD

ATA

10

0

Le

ge

nd

:

Da

ta

I²C

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

LA

N

Super

I/O

MC

H

RA

ID

ke

y

Slo

t 2

Slo

t 1

CS

S

button

Ad

ap

ter

SA

S

US

B

<-

P9

Flo

ppy

(optional)

Optical drive

(top)

Tape

(mid

dle

)

Tape

(bottom

)

PS

U

E520-V

70

<-

P1

<-

P8

P5

->

P4

->

P2

->

P3

->

P1

0 -

>

P6

->

HD

1-4

SA

S/S

ATA

Bpl

3.5

A3C

40070504

X9

X1

X11

Page 94: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

94 Options Guide TX150 S6

Cabling Appendix

Figure 78: Cabling - standard PS, 3.5“ hard disks, 3.5“ hard disks extension box

Cable

pre

fix: T

26139-

Pow

er

SA

TA

IDE

/FD

ATA

100

Legend:

Data

I²C

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

LA

N

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

US

B

<-

P9

Flo

ppy

(optional)

Optical drive

(top)

PS

U

E5

20

-V7

0

<-

P1

<-

P8

P5 -

>

P4 -

>

P2 -

>

P3 -

>

P10 -

>

P6 -

>H

D 1

-4

SA

S/S

ATA

Bpl

3.5

A3C

40070504

X9

X1

X11

HD

5-6

SA

S/S

ATA

Bpl

3.5

A3C

40069429

X5

X1

X7

HD

exte

nsio

n

box

Page 95: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 95

Appendix Cabling

Figure 79: Cabling - standard PS, 2.5“ hard disks

Cable

pre

fix: T

26139-

Pow

er

SA

TA

IDE

/FD

ATA

100

Legend:

Data

I²C

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

LA

N

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

US

B

<-

P9

Flo

ppy

(optional)

Optical drive

(top)

Tape

(mid

dle

)

Tape

(bottom

)

PS

U

E5

20

-V7

0

<-

P1

<-

P8

P5 -

>

P4 -

>

P2 -

>

P3 -

>

P10 -

>

P6 -

>H

D 1

-4

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

HD

5-6

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

Page 96: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

96 Options Guide TX150 S6

Cabling Appendix

Figure 80: Cabling- hot-plug PS, 3.5“ hard disks

Cable

pre

fix: T

26139-

Pow

er

SA

TA

IDE

/FD

ATA

100

Legend:

Data

I²C

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

LA

N

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

US

B

<-

P9

Flo

ppy

(optional)

Optical drive

(top)

Tape

(mid

dle

)

Tape

(bottom

)

PS

U

E4

83

-V5

0

<-

P1

<-

P8

P5 -

>

P4 -

>

P2 -

>

P3 -

>

P6 -

>H

D 1

-4

SA

S/S

ATA

Bpl

3.5

A3C

40070504

X9

X1

X11

Y3930-V

101

Page 97: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 97

Appendix Cabling

Figure 81: Cabling- hot-plug PS, 3.5“ hard disks, slimline optical drive

Cable

pre

fix: T

26139-

Pow

er

SA

TA

IDE

/FD

ATA

100

Legend:

Data

I²C

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

LA

N

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

US

B

<-

P9

Flo

ppy

(optional)

Slim

line

optical drive (

top)

Tape

(mid

dle

)

Tape

(bottom

)

PS

U

E4

83

-V5

0

<-

P1

<-

P8

P5 -

>

P4 -

>

P2 -

>

P3 -

>

P6 -

>H

D 1

-4

SA

S/S

ATA

Bpl

3.5

A3C

40070504

X9

X1

X11

Y3990-V

1

Page 98: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

98 Options Guide TX150 S6

Cabling Appendix

Figure 82: Cabling- standard PS, 3.5“ hard disks, slimline optical drive

Cable

pre

fix: T

26139-

Pow

er

SA

TA

IDE

/FD

ATA

100

Legend:

Data

I²C

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

LA

N

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

US

B

<-

P9

Flo

ppy

(optional)

Slim

line

optical drive (

top)

Tape

(mid

dle

)

Tape

(bottom

)

<-

P1

<-

P8

P5 -

>

P4 -

>

P2 -

>

P3 -

>

P6 -

>H

D 1

-4

SA

S/S

ATA

Bpl

3.5

A3C

40070504

X9

X1

X11

Y3990-V

201

PS

U

E5

20

-V7

0

P10 -

>

Page 99: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 99

Appendix Cabling

Figure 83: Cabling - hot-plug PS, 3.5“ hard disks, 3.5“ hard disks extension box

Cable

pre

fix: T

26139-

Pow

er

SA

TA

IDE

/FD

ATA

100

Legend:

Data

I²C

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

LA

N

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

US

B

<-

P9

Flo

ppy

(optional)

Optical drive

(top)

PS

U

E4

83

-V5

0

<-

P1

<-

P8

P5 -

>

P4 -

>

P6 -

>H

D 1

-4

SA

S/S

ATA

Bpl

3.5

A3C

40070504

X9

X1

X11

Y3930-V

101

P2 -

>

P3 -

>H

D 5

-6

SA

S/S

ATA

Bpl

3.5

A3C

40069429

X5

X1

X7

HD

exte

nsio

n

box

Page 100: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

100 Options Guide TX150 S6

Cabling Appendix

Figure 84: Cabling - hot-plug PS, 2.5“ hard disks

Cable

pre

fix: T

26139-

Pow

er

SA

TA

IDE

/FD

ATA

100

Legend:

Data

I²C

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

LA

N

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

US

B

<-

P9

Tape

(mid

dle

)

Tape

(bottom

)

PS

U

E4

83

-V5

0

<-

P1

<-

P8

P2 -

>

P3 -

>

P6 -

>

HD

1-4

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

HD

5-6

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1F

loppy

(optional)

Optical drive

(top)

P5 -

>

P4 -

>

Y3930-V

101

Y2193-V

211

Page 101: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 101

Appendix Cabling

Figure 85: Cabling - hot-plug PS, 2.5“ hard disks, 2.5“ hard disks extension box

Cable

pre

fix: T

26139-

Pow

er

SA

TA

IDE

/FD

ATA

100

Legend:

Data

I²C

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

LA

N

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

US

B

<-

P9

PS

U

E4

83

-V5

0

<-

P1

<-

P8

P2 -

>

P3 -

>

P6 -

>

HD

1-4

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

HD

5-6

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

Flo

ppy

(optional)

Optical drive

(top)

P5 -

>

P4 -

>

Y3930-V

101

Y2193-V

211

HD

1-4

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

HD

5-6

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

Y2193-V

211

HD

exte

nsio

n

box

Page 102: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

102 Options Guide TX150 S6

Cabling Appendix

Figure 86: Cabling- data, USB, I2C, 1x 2.5“ hard disks

Cable

pre

fix: T

26139-

Pow

er

SA

TA

ATA

100

Legend:S

lot

3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

IDE

/FD

Data

I²C

US

B

Flo

ppy

(optional)

Optical drive

(top)

US

B tape

(mid

dle

)

SA

S tape

(bottom

)

HD

1-4

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

Opera

ting p

anel

A3C

40038243

IDTem

p C

om

bo

A3C

40078709

Intr

usio

n s

w.

Intr

usio

n s

w.

Syste

m

fan

Y3736-V

1

Y3718-V

5

Y3963-V

101

Y3969-V

102

Y3958-V

203

Y1248-V

8

Y3904-V

101

Y2603-V

7

US

B-B

to U

SB

tape

CH

0

SA

S c

ontr

oller

1-c

hannel

Page 103: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 103

Appendix Cabling

Figure 87: Cabling- data, USB, I2C, 2x 2.5“ hard disks

Cable

pre

fix: T

26139-

Pow

er

SA

TA

ATA

100

Legend:S

lot

3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

IDE

/FD

Data

I²C

US

B

Flo

ppy

(optional)

Optical drive

(top)

US

B tape

(mid

dle

)

SA

S tape

(bottom

)

HD

1-4

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

IDTem

p C

om

bo

A3C

40078709

Intr

usio

n s

w.

Intr

usio

n s

w.

Syste

m

fan

Y3736-V

1

Y3718-V

5Y

3963-V

101

Y3969-V

102

Y3958-V

203

Y1248-V

8

Y3904-V

101

Y2603-V

7

US

B-B

to U

SB

tape

CH

0S

AS

contr

oller

1-c

hannel

SA

TA

RA

ID c

ontr

oller

2-c

hannel

HD

5-8

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

CH

0

CH

1

Y3963-V

101

Opera

ting p

anel

A3C

40038243

Page 104: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

104 Options Guide TX150 S6

Cabling Appendix

Figure 88: Cabling- data, USB, I2C, 2x 2.5“ hard disks

Cable

pre

fix: T

26139-

Pow

er

SA

TA

ATA

100

Legend:S

lot

3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

IDE

/FD

Data

I²C

US

B

Flo

ppy

(optional)

Optical drive

(top)

US

B tape

(mid

dle

)

SA

S tape

(bottom

)

HD

1-4

SA

S/S

ATA

Bpl

3.5

A3C

40070504

X9

X1

IDTem

p C

om

bo

A3C

40078709

Intr

usio

n s

w.

Intr

usio

n s

w.

Syste

m

fan

Y3736-V

1

Y3718-V

508

Y3963-V

101

Y3969-V

102

Y3958-V

203

Y1248-V

8

Y3904-V

101

Y2603-V

7

US

B-B

to U

SB

tape

CH

0

SA

S c

ontr

oller

1-c

hannel

X11

Opera

ting p

anel

A3C

40038243

Page 105: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 105

Appendix Cabling

Figure 89: Cabling- data, USB, I2C, 3.5“ hard disks, 3.5“ hard disks extension box

Cable

pre

fix: T

26139-

Pow

er

SA

TA

ATA

100

Legend:S

lot

3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

IDE

/FD

Data

I²C

US

B

Flo

ppy

(optional)

Optical drive

(top)

IDTem

p C

om

bo

A3C

40078709

Intr

usio

n s

w.

Intr

usio

n s

w.

Syste

m

fan

Y3736-V

1

Y3718-V

508

Y3963-V

1

Y3958-V

203

Y1248-V

8

Y3904-V

101

Y2603-V

7

SA

TA

RA

ID c

ontr

oller

2-c

hannel

CH

0

CH

1

Y3963-V

201

HD

1-4

SA

S/S

ATA

Bpl

3.5

A3C

40070504

X9

X1

X11

HD

5-6

SA

S/S

ATA

Bpl

3.5

A3C

40069429

X5

X1

X7

HD

exte

nsio

n

box

Opera

ting p

anel

A3C

40038243

Page 106: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

106 Options Guide TX150 S6

Cabling Appendix

Figure 90: Cabling- data, USB, I2C, 2.5“ hard disks, 2.5“ hard disks extension box

Cable

pre

fix: T

26139-

Pow

er

SA

TA

ATA

100

Legend:S

lot

3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

IDE

/FD

Data

I²C

US

B

Flo

ppy

(optional)

Optical drive

(top)

HD

1-4

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

IDTem

p C

om

bo

A3C

40078709

Intr

usio

n s

w.

Intr

usio

n s

w.

Syste

m

fan

Y3736-V

1

Y3718-V

5

Y3963-V

101

Y3963-V

103

Y3958-V

203

Y1248-V

8

Y3904-V

101

Y2603-V

7

SA

S R

AID

contr

oller

2-c

hannel

HD

5-8

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

CH

0

CH

1

Y3963-V

101

HD

1-4

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

HD

5-6

SA

S/S

ATA

Bpl

2.5

A3C

40086493

X6

X1

HD

exte

nsio

n

box

SA

S R

AID

contr

oller

2-c

hannel

CH

0

CH

1

Y3963-V

103

Opera

ting p

anel

A3C

40038243

Page 107: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 107

Appendix Cabling

Figure 91: Cabling - 2x SATA optical drives

Cable

pre

fix: T

26139-

Pow

er

SA

TA

ATA

100

Legend:S

lot

3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

IDE

/FD

Data

I²C

US

B

1st optical drive

(top)

Y3958-V

203

CH

0

2nd o

ptical drive

(mid

dle

)Y

3958-V

203

Page 108: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

108 Options Guide TX150 S6

Cabling Appendix

Figure 92: Cabling - ServerView Local Service Panel

Cable

pre

fix: T

26139-

Pow

er

SA

TA

ATA

100

Legend:S

lot

3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

IDE

/FD

Data

I²C

US

B

Y3718-V

5

CH

0

Serv

erV

iew

Local S

erv

ice P

anel

X3

Opera

ting p

anel

A3C

40038243

Page 109: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 109

Appendix Cabling

Figure 93: Cabling - 2x SCSI tape

Cable

pre

fix: T

26139-

Pow

er

SA

TA

ATA

100

Legend:S

lot

3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

IDE

/FD

Data

I²C

US

B

SC

SI ta

pe

(top)

Y3980-V

11

CH

0

SC

SI ta

pe

(mid

dle

)

SC

SI contr

oller

Page 110: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

110 Options Guide TX150 S6

Cabling Appendix

Figure 94: Cabling - external interfaces

Cable

pre

fix: T

26139-

Pow

er

SA

TA

ATA

100

Legend:

Slo

t 3

CP

U

iRM

C

Battery

Slo

t 4

Slo

t 5

Slo

t 6

Super

I/O

MC

H

RA

ID

key

Slo

t 2

Slo

t 1

CS

S

button

Adapte

r

SA

S

IDE

/FD

Data

I²C

US

B

CH

0

Y3910-V

1

Slo

t 7

Y5389-V

405

Page 111: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 111

AbbreviationsAC

Alternating Current

ANSIAmerican National Standards Institute

ASR&RAutomatic Server Reconfiguration and Restart

BIOSBasic Input-Output System

CCCache Coherency

CDCompact Disk

CD-ROMCompact Disk-Read Only Memory

CHSCylinder Head Sector

CMOSComplementary Metal Oxide Semiconductor

COMCommunication

CPUCentral Processing Unit

DCDirect Current

DIMMDual Inline Memory Module

Page 112: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

112 Options Guide TX150 S6

Abbreviations

DIPDual Inline Package

DMADirect Memory Access

DMIDesktop Management Interface

ECCError Checking and Correcting

ECPExtended Capabilities Port

EEPROMElectrically Erasable Programmable Read-Only Memory

EGBElektrostatisch Gefährdete Bauteile (components in danger of electro-static discharge)

EMPEmergency Management Port

EPPEnhanced Parallel Port

EMVElektromagnetische Verträglichkeit (electromagnetic compatibility)

ESDElectrostatic Discharge

FPCFront Panel Controller

FRUField Replaceable Unit

FSBFront Side Bus

Page 113: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 113

Abbreviations

GAMGlobal Array Manager

GUIGraphical User Interface

HDDHard Disk Drive

HSCHot-Swap Controller

I²CInter-Integrated Circuit

I/OInput/Output

ICMIntelligent Chassis Management

IDIdentification

IDEIntegrated Drive Electronics

IOOPIntelligent Organization of PCI

iRMCintegrated Remote Management Controller

IRQInterrupt Request Line

LANLocal Area Network

LBALogical Block Address

Page 114: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

114 Options Guide TX150 S6

Abbreviations

LCDLiquid Crystal Display

LUNLogical Unit Number

LVDLow-Voltage Differential SCSI

LWLOptical Waveguide

MMFMulti Mode Faser

MRLManual Retention Latch

NMINon Maskable Interrupt

NVRAMNon Volatile Random Access Memory

OSOperating System

PCIPeripheral Component Interconnect

PDAPrefailure Detection and Analyzing

POSTPower ON Self Test

RAIDRedundant Arrays of Independent Disks

RAMRandom Access Memory

Page 115: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 115

Abbreviations

ROMRead-Only Memory

RSBRemote Service Board

RTCReal Time Clock

RTDSRemote Test and Diagnosis System

SAF-TESCSI Accessed Fault-Tolerance Enclosures

SASSerial Attached SCSI

SATASerial ATA

SBESingle Bit Error

SCASingle Connector Attachment

SCSISmall Computer System Interface

SDRSensor Data Record

SDRAMSynchronous Dynamic Random Access Memory

SELSystem Event Log

SMISystem Management Interrupt

Page 116: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

116 Options Guide TX150 S6

Abbreviations

SSUSystem Setup Utility

SVGASuper Video Graphics Adapter

USBUniversal Serial Bus

VGAVideo Graphics Adapter

ZCRZero Channel RAID

Page 117: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small

TX150 S6 Options Guide 117

IndexAaccessible drives 9, 33

BBBU 61

CCOM2 interface 10, 65conversion of floorstand model to rack

model 10, 79conversion standard PS to hot-plug

PS 10, 69

DDVD drive 35

Eelectrostatic-sensitive devices

(ESD) 20ESD (electrostatic-sensitive

devices) 20expansion cards 10, 58external interfaces 65

Ffloppy disk drive 37floppy disk drive holder 37front cover 22, 86

Hhard disk drive cover 24, 85hard disks extension box 9, 39

Iinformation material, additional 8

Llaser information 19light emitting diode (LED) 19lithium battery 18

Mmain memory 9, 29meaning of the symbols 11

Nnotational conventions 11

Pparallel interface 10, 66PCI slots 57

Rrack front cover 28, 88RAID key 63

SServerView Local Service Panel 9,

49

Ttarget group 7

Page 118: PRIMERGY TX150 S6 Server - Fujitsumanuals.ts.fujitsu.com/file/4122/tx150s6-og-en.pdfTX150 S6 Options Guide 7 1 Preface The PRIMERGY TX150 S6 server is an Intel-based server for small