price list 2014 sale by empowering staff to make key decisions face to face with customers. hawco...

68
your comfort. our world. www.hawco.co.uk [email protected] +44 (0) 1483 869070 The Critical Component of your Business’s Success refrigeration air conditioning heating electrical control Price List 2014

Upload: trandieu

Post on 18-Mar-2018

222 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

your comfort. our world.

[email protected]

+44 (0) 1483 869070The Critical Component of your Business’s Success

refrigeration • air conditioning • heating • electrical • control

Price List 2014

Page 2: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Head OfficeHawcoThe WharfAbbey Mill Business ParkLower EashingGodalmingSurrey GU7 2QNUK

01483 869070 [email protected]

Distribution CentreHawco8 Cranfield RoadLostock Industrial EstateLostockBolton BL6 4SB

Hawco was established in 1973 and for the past 40 years has been one of the UK’s leading suppliers of equipment, components, spares and accessories to the Refrigeration, Air Conditioning, Heating, Electrical and Control industries. Working alongside some of the world’s leading brands, Hawco has sculpted a reputation for excellence as a full-service provider, delivering industry leading customer service and technical support as well as concept, product development and design.

Hawco’s head office is based in Godalming, Surrey. We have a single Distribution Centre in Bolton that caters to the entire UK and all International customers. Complimenting operations, we have a dedicated technical solutions department and a team of knowledgeable internal and field sales engineers. By adapting a structured business model, we can offer solutions at the point of sale by empowering staff to make key decisions face to face with customers.

Hawco

Conditions

Capacity conditionsUnit cooling and heating capacities shown within this price list are based on the following conditions:

Nominal cooling Ambient = 35°CInternal = 27°C db 19°C wb

Nominal heating Ambient = 7°C db 6°C wbInternal = 20°C db

UK cooling Ambient = 30°CInternal = 22°C db 16°C wb

Seasonal efficiencySystems of up to 12kW must now show Seasonal Efficiency Ratings instead of Nominal Efficiency Ratings. These ratings (SEER for cooling, SCOP for heating) represent how effective a system is throughout the year, and are in accordance with EN14825. For more information on Seasonal Efficiency, visit www.daikin.co.uk/seasonal-efficiency

For Daikin UK, this means all our Split and Sky Air products up to 12kW display SEER and SCOP data along with Energy Label information and Annual Energy Consumption of the system. The AEC is based upon 500 hours use per year.

Nominal efficiency This measure of efficiency is calculated by dividing the capacity output of a unit by the power required to deliver it. For cooling, this is expressed as EER, for heating as COP.

Nominal efficiencies are used for systems above 12kW. It is not possible to compare nominal and Seasonal Efficiency ratings.

Cooling mode

Unless otherwise indicated, all units within this price list are air-cooled.

UK. prefix accessories All accessory items shown in this price list with the prefix ‘UK.’ are not manufactured by Daikin.

Page 3: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

ContentsSplit, Sky Air Heat Pumps 3

VRV 43

Ventilation 45

Applied 47

Miscellaneous 59

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Price List 2014 1

VRV

VEN

TILA

TIO

NA

PPLI

EDM

ISCE

LLA

NEO

US

Page 4: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

The Gym, Broad Street Mall, Reading

Page 5: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Split, Sky Air Heat PumpsEnergy Related Products Directive Update 4

Enhanced Capital Allowance (ECA) Scheme 4

Introduction 5

Pair Applications 7

Wall Mounted Split Systems 7

Floor Standing Split Systems 12

Flexi Type Split Systems 16

Ceiling Mounted Split Systems 17

Cassette Split Systems 21

Under Ceiling Cassette Split Systems 28

Ducted Split Systems 29

Multi Applications 34

Multi Split Systems 34

Twin, Triple, Double Twin Systems 36

Price List 2014 3

Page 6: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial4

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Energy efficiency class SEER SCOP

SEER ≥ 8.50 SCOP ≥ 5.10

6.10 ≤ SEER < 8.50 4.60 ≤ SCOOP < 5.10

5.60 ≤ SEER < 6.10 4.00 ≤ SCOOP < 4.60

5.10 ≤ SEER < 5.60 3.40 ≤ SCOOP < 4.00

4.60 ≤ SEER < 5.10 3.10 ≤ SCOOP < 3.40

4.10 ≤ SEER < 4.60 2.80 ≤ SCOOP < 3.10

3.60 ≤ SEER < 4.10 2.50 ≤ SCOOP < 2.80

Enhanced Capital Allowance (ECA) scheme

The ErP Directive has been updated as of January 1st 2014 to ensure products up-to 12kW are even more efficient.

Energy Related Products directive update

The ErP originally came into force January 1st 2013 and implemented minimum energy efficiency standards for products up to 12kW, which covers most of Daikin’s split & sky air ranges.

The original and the new minimum standards can be seen in the table. These standards are for cooling (SEER) and heating (SCOP) and are based on Seasonal Efficiency rather than nominal efficiency. This is a more accurate way of looking at efficiency as it takes into account seasonal temperature variations, part load performance and power consumed on stand-by.

The minimum standards are enforced through Energy Labelling – with the label clearly displaying the SEER and SCOP along with relevant Energy Label.

All Daikin split and Sky products clearly list the SEER, SCOP and Energy Label data. Many of these products achieve A++ or A+++ Energy Labels, making them some of the most efficient available.

Multi split and twin, triple systems up to 12kW must also have energy labels. It is possible to obtain Energy Label data for multi, twin and triple systems up to 12kW at www.daikineurope.com/energylabel

2013 2014

SEER < 6kW3.6

4.6

SEER ≥ 6kW 4.3

SCOP 3.4 3.8

Daikin energy-efficient technology has achieved further recognition. You’ll now find more of our air conditioning units on the Energy Technology List (ETL) – the definitive list of products that qualify for Enhanced Capital Allowance (ECA).

Our products have now been confirmed as among the most efficient in the market.

You can now be confident of offering your customers Daikin equipment that is ECA-qualified. This will enable you to compete for jobs wherever this is a specific requirement of the end-user.

How to check eligibility for ECA tax relief:

The ECA scheme is open to all businesses that pay Corporation Tax or Income Tax.

Confirming ECA product eligibility is easy. The Carbon Trust publishes the ETL on behalf of the Government. You or your customers can find this at www.etl.decc.gov.uk/etl/site.html

What’s changed – and why?Technological progress and changes to legislation have recently led to efficiency performance thresholds being raised.

As a result, older products from a number of manufacturers became ineligible for ECA and have now been removed from the ETL.

However, the Daikin additions to the list now mean we currently offer a wider choice of ECA-eligible air conditioning products than any other manufacturer. And even more of our units are expected to appear on the ETL early in 2014.

OLD THRESHOLDS NEW THRESHOLDS Change

EER COP SEER SCOP

<12kW Split 3.21 3.61 6.10 4.00 Move to seasonal

>12kW Split 3.21 3.61 3.21 3.71 +0.1 (COP)

>12kW VRV 3.30 3.70 3.40 3.80 +0.1 (COP & EER)

Minimum requirements

Page 7: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 5

SPLI

T, S

KY

AIR

HEA

T PU

MPS

The three SkyAir ranges from Daikin now ensure you can satisfy the needs of every customer – and help you WIN more projects. Whether your customers want to maximise energy-efficiency, optimise their running costs, or simply keep the up-front cost to a minimum, you will always have the right answer ready for them with SkyAir.

Sky Air – The range that has all the right answers

Add-on options extra efficiency for your customers

Make sure you offer your customers the benefits of Daikin add-on options – especially with Seasonal Smart. These can

help cut future operating costs even further. Options include:

Self-Cleaning Cassette Cassette Presence Sensor

RTDs To see how extra energy-saving options can

deliver significant savings for your customers, try the SkyAir Selection tool.

Visit: daikin.co.uk/win

Compare the three ranges and get to know the choices:SkyAir gives you three reasons to win with Daikin

SiestaThe ECONOMY option• Low purchase price for reduced upfront cost

• Compatible with Daikin Siesta SkyAir cassette, ceiling-suspended and ducted indoor units

• Allows pipe runs up to 50m

• Ideal for new installations

• Good operating range for most UK climate conditions

• EU energy ratings: Up to B for cooling and A for heating

Seasonal ClassicThe all-rounder STANDARD option• Suitable for triple and twin applications

• Connection to up to four indoor units

• Compatible with existing R22 system pipework

• Compatible with most Daikin SkyAir indoor units including wall, floor and large-ducted options

• Allows pipe runs up to 50m

• Good operating range for most UK climate conditions

• EU energy ratings: Up to A++ for cooling and A+ for heating

Seasonal SmartThe top-of-range PREMIUM optionOffering all the same features as Seasonal Classic, plus…

• Industry-leading energy efficiency

• Longer pipe runs – up to 75m

• EDP setting for comms rooms

• Wide operating range able to cope efficiently with unusual temperature extremes

• Optional slim under-ceiling cassette: for comfortable all-round airflow in buildings with solid ceilings or limited-depth ceiling voids

• EU energy ratings: Up to A++ for both heating and cooling modes

• Listed on the Energy Technology List (ETL)

Page 8: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Residential, Commercial and Industrial6

Page 9: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 7

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Wall Mounted – InverterEmura

Indoor Units Matt Crystal White SilverFTXG20LW FTXG25LW FTXG35LW FTXG50LW FTXG20LS FTXG25LS FTXG35LS FTXG50LS

Capacity UK Total Cooling kW 2.25 2.35 3.42 4.69 2.25 2.35 3.42 4.69UK Sensible Cooling kW 1.84 1.88 2.51 3.09 1.84 1.88 2.51 3.09Nominal Cooling kW 2.00 2.50 3.50 5.00 2.00 2.50 3.50 5.00Nominal Heating kW 2.50 3.40 4.00 5.80 2.50 3.40 4.00 5.80

Seasonal Efficiency (EN14825) COOLING

Energy Label A+++ A+++ A++ A++ A+++ A+++ A++ A++Pdesign kW 2.30 2.40 3.50 4.80 2.30 2.40 3.50 4.80SEER 8.52 8.50 7.00 6.70 8.52 8.50 7.00 6.70Annual Energy Consumption kWh 94 99 175 251 94 99 175 251

Seasonal Efficiency (EN14825) HEATING

Energy Label A++ A++ A++ A+ A++ A++ A++ A+Pdesign kW 2.10 2.70 3.00 4.60 2.10 2.70 3.00 4.60SCOP 4.60 4.60 4.60 4.24 4.60 4.60 4.60 4.24Annual Energy Consumption kWh 639 821 913 1519 639 821 913 1519

Nominal Efficiency EER / COP 4.59 / 5 4.59 / 4.42 3.97 / 4.06 3.53 / 3.65 4.59 / 5 4.59 / 4.42 3.97 / 4.06 3.53 / 3.65Energy Label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 250 261 441 680 250 261 441 680

Air Flow Rate High / Low m3/min 8.8 / 4.4 8.8 / 4.4 11 / 4.8 11.3 / 6.8 8.8 / 4.4 8.8 / 4.4 11 / 4.8 11.3 / 6.8Dimensions Height mm 303 303

Width mm 998 998Depth mm 212 212

Weight kg 12 12 12 12 12 12 12 12Sound Pressure High / Low dBA 38 / 25 38 / 25 45 / 26 45 / 35 38 / 25 38 / 25 45 / 26 45 / 35Sound Power dBA 54 54 59 60 54 54 59 60

Outdoor Units RXG20L RXG25L RXG35L RXG50L RXG20L RXG25L RXG35L RXG50LDimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 550 x 765 x 285 735 x 825 x 300Weight kg 35 48 35 48Electrical Details Power Supply 1ph 1ph

Running Current A 2.70 2.80 4.80 6.20 2.70 2.80 4.80 6.20Starting Current A 2.8 4.4 5.5 7.4 2.8 4.4 5.5 7.4Max Fuse Size A 16 16 16 20 16 16 16 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5 3+E / 1.5 3+E / 2.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2Pipework Maximum Length m 20 20 20 30 20 20 20 30

Maximum Vertical Rise m 15 15 15 20 15 15 15 20Precharged to m 10 10 10 10 10 10 10 10Additional Charge g/m 20 20Holding Charge kg 1.05 1.05 1.05 1.6 1.05 1.05 1.05 1.6

Sound Pressure High dBA 46 46 48 48 46 46 48 48Sound Power dBA 61 61 63 63 61 61 63 63

Trade Fan Coil Price £262.00 £276.00 £310.00 £473.00 £313.00 £329.00 £369.00 £565.00Trade Condensing Unit Price £478.00 £504.00 £585.00 £936.00 £478.00 £504.00 £585.00 £936.00Total System Price £740.00 £780.00 £895.00 £1,409.00 £791.00 £833.00 £954.00 £1,501.00

Features:• Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round • It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling • Stylish, low-profile design • Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming.

Up to 4 actions per day possible • Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops • Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room • 2-area intelligent eye: air flow is sent to a zone other than where the occupants are located at that moment • Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins • Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting • Fan speed: 5 fan speeds can be selected, high to super low • Suitable for multi model applications • Re-use of existing R22 and R407C piping possible

Accessory Ref Description Trade PriceBRC944 Optional Wired Remote controller £64.00 BRCW901A03 3m connection cable for BRC944 £17.00 BRCW901A08 8m connection cable for BRC944 £22.00 BRP069A41 Adaptor for connection to on-line controller £40.00KRP413A1S Adaptor PCB for remote on/off control - constant/pulse contact £75.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £132.00 KLIC-DD KNX interface for Split type systems £164.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £151.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Accessories: Notes:i) All fan coil units standard with auto restart

after power failure

ii) All fan coils supplied as standard with infrared remote controller

iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined

iv) Minimum ambient operating temperatures:

Cooling HeatingRXG -10°C -15°C

WI-FI

CONTROL

VIA APP

Page 10: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial8

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Wall Mounted – InverterFTXS-K/G

Indoor Units FTXS20K FTXS25K FTXS35K FTXS42K FTXS50K FTXS60G FTXS71GCapacity UK Total Cooling kW 1.95 2.44 3.42 4.11 4.56 5.86 6.94

UK Sensible Cooling kW 1.65 1.82 2.56 2.85 3.14 3.87 4.65Nominal Cooling kW 2.00 2.50 3.50 4.20 5.00 6.00 7.10Nominal Heating kW 2.50 3.40 4.00 5.40 5.80 7.00 8.20

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A++ A++ A++ A APdesign kW 2.00 2.50 3.50 4.20 5.00 6.00 7.10SEER 7.40 7.90 7.47 6.80 6.80 5.58 5.23Annual Energy Consumption kWh 95 111 164 216 257 376 475

Seasonal Efficiency (EN14825) HEATING

Energy Label A++ A++ A++ A+ A+ A APdesign kW 2.30 2.50 3.60 4.00 4.60 4.80 6.50SCOP 4.77 4.78 4.85 4.20 4.20 3.89 3.50Annual Energy Consumption kWh 675 732 1039 1334 1535 1728 2593

Nominal Efficiency EER / COP 4.65 / 4.72 4.39 / 4.67 4.07 / 4.76 3.56 / 4.12 3.55 / 4 3.02 / 3.43 3.02 / 3.22Energy Label A / A A / A A / A A / A A / A B / B B / CAnnual Energy Consumption kWh 215 285 430 590 705 995 1175

Air Flow Rate High / Low m3/min 8.8 / 4.7 9.1 / 5 11.2 / 5.8 11.2 / 7 11.9 / 7.4 16 / 11.3 17.2 / 11.5Dimensions Height mm 289 289 298 298 298 290 290

Width mm 780 780 900 900 900 1050 1050Depth mm 215 215 215 215 215 250 250

Weight kg 8 8 11 11 11 12 12Sound Pressure High / Low dBA 40 / 24 41 / 25 45 / 29 45 / 33 46 / 34 45 / 36 46 / 37Sound Power dBA 58 58 59 59 60 61 62

Outdoor Units RXS20L RXS25L RXS35L RXS42L RXS50L RXS60L RXS71F8Dimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 770 x 900 x 320Weight kg 34 34 34 39 47 48 71Electrical Details Power Supply 1ph 1ph

Running Current A 2.30 3.10 4.10 5.70 6.30 8.80 10.49Starting Current A 2.8 3.3 4.3 6.6 6.8 9.4 11.7Max Fuse Size A 10 10 10 20 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 1/4 / 5/8Pipework Maximum Length m 20 20 20 20 30 30 30

Maximum Vertical Rise m 15 15 15 15 20 20 20Precharged to m 10 10 10 10 10 10 10Additional Charge g/m 20 20Holding Charge kg 1.0 1.0 1.2 1.3 1.7 1.5 2.3

Sound Pressure High dBA 46 46 48 48 48 49 52Sound Power dBA 59 59 61 61 62 62 65

Trade Fan Coil Price £154.00 £165.00 £189.00 £212.00 £294.00 £300.00 £400.00Trade Condensing Unit Price £436.00 £476.00 £552.00 £623.00 £694.00 £740.00 £1,013.00Total System Price £590.00 £641.00 £741.00 £835.00 £988.00 £1,040.00 £1,413.00

Features:• Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible• Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops• Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room• 2-area intelligent eye: (35~50 K class) air flow is sent to a zone other than where the occupants are located at that moment• Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins• Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting• Fan speed: 5 fan speeds can be selected, high to super low• Suitable for multi model applications• Re-use of existing R22 and R407C piping possible

Accessory Ref Description Trade PriceKRP980A1 Adaptor for FTXS20K & 25K for ALL control options £68.00 BRC944 Optional Wired Remote controller £64.00 BRCW901A03 3m connection cable for BRC944 £17.00 BRCW901A08 8m connection cable for BRC944 £22.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £132.00 KLIC-DD KNX interface for Split type systems £164.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £151.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Accessories: Notes:i) All fan coil units standard with auto restart

after power failure

ii) All fan coils supplied as standard with infrared remote controller

iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined

iv) FTXS-K and FTXS-G have different style casing

v) Minimum ambient operating temperatures:

Cooling HeatingRXS -10°C -15°C

FTXS-G seriesFTXS-K series

Page 11: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 9

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Wall Mounted – Low InverterFTX-J/G

Indoor Units FTX20JV FTX25JV FTX35JV FTX50GV FTX60GV FTX71GVCapacity UK Total Cooling kW 1.95 2.44 3.07 4.89 5.86 6.94

UK Sensible Cooling kW 1.60 1.78 2.11 3.32 3.88 4.46Nominal Cooling kW 2.00 2.50 3.30 5.00 6.00 7.10Nominal Heating kW 2.50 2.80 3.50 5.80 7.00 8.20

Seasonal Efficiency (EN14825) COOLING

Energy Label A+ A+ A+ A+ A BPdesign kW 2.00 2.50 3.30 5.00 6.00 7.10SEER 5.63 5.63 5.66 5.63 5.37 4.97Annual Energy Consumption kWh 124 155 204 311 391 500

Seasonal Efficiency (EN14825) HEATING

Energy Label A++ A+ A+ A+ A APdesign kW 2.20 2.40 2.80 4.60 4.80 6.20SCOP 4.67 4.50 4.14 4.08 3.88 3.81Annual Energy Consumption kWh 660 747 945 1578 1730 2276

Nominal Efficiency EER / COP 3.64 / 4.24 3.42 / 4.06 3.37 / 3.76 3.23 / 3.63 3.02 / 3.43 3.02 / 3.22Energy Label A / A A / A A / A A / A B / B B / CAnnual Energy Consumption kWh 275 365 490 775 995 1175

Air Flow Rate High / Low m3/min 9.1 / 5.9 9.2 / 6 9.3 / 6.1 14.7 / 10.3 16.2 / 11.4 17.4 / 11.6Dimensions Height mm 283 283 283 290 290 290

Width mm 770 770 770 1050 1050 1050Depth mm 198 198 198 238 238 238

Weight kg 7 7 7 12 12 12Sound Pressure High / Low dBA 39 / 25 40 / 26 41 / 27 43 / 34 45 / 36 46 / 37Sound Power dBA 55 55 58 59 60 63

Outdoor Units RX20JV RX25JV RX35JV RX50GV RX60GVB RX71GVBDimensions Height x Width x Depth mm 550 x 658 x 275 735 x 825 x 300 770 x 900 x 320Weight kg 28 28 30 48 47 71Electrical Details Power Supply 1ph 1ph

Running Current A 2.49 3.49 4.99 6.75 8.62 10.40Starting Current A 2.7 3.7 5.0 7.4 9.4 11.7Max Fuse Size A 16 16 16 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 1/4 / 5/8Pipework Maximum Length m 15 15 15 30 30 30

Maximum Vertical Rise m 12 12 12 20 20 20Precharged to m 10 10 10 10 10 10Additional Charge g/m 20.0 20.0Holding Charge kg 0.7 0.7 1.0 1.5 1.5 2.3

Sound Pressure High dBA 46 46 48 47 49 52Sound Power dBA 60 60 62 61 63 65

Trade Fan Coil Price £123.00 £136.00 £154.00 £250.00 £255.00 £341.00Trade Condensing Unit Price £364.00 £389.00 £453.00 £590.00 £629.00 £904.00Total System Price £487.00 £525.00 £607.00 £840.00 £884.00 £1,245.00

Features:• Wireless remote controller with daily timer• Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops• Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room• Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting• Fan speed: 5 fan speeds can be selected, high to super low• Suitable for multi model applications• Re-use of existing R22 and R407C piping possible

Accessory Ref Description Trade PriceUK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Accessories: Notes:i) All fan coils supplied as standard with

infrared remote controller

ii) All fan coil units standard with auto restart after power failure

iii) Minimum ambient operating temperatures:

Cooling HeatingRX-JV +10°C -15°CRX-GVB -10°C -15°C

Page 12: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial10

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Wall Mounted – Seasonal Smart Inverter FAQ-C / RZQG

Indoor Units Single Phase 3 Phase FAQ71C FAQ100C FAQ71C FAQ100C

Capacity UK Total Cooling kW 7.76 10.80 7.76 10.80UK Sensible Cooling kW 5.32 7.44 5.32 7.44Nominal Cooling kW 6.80 9.50 6.80 9.50Nominal Heating kW 7.50 10.80 7.50 10.80

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A++ A++Pdesign kW 6.80 9.50 6.80 9.50SEER 6.51 6.11 6.51 6.11Annual Energy Consumption kWh 365 544 365 544

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A+ A+ A+Pdesign kW 6.33 10.20 6.33 10.20SCOP 4.02 4.01 4.02 4.01Annual Energy Consumption kWh 2204 3561 2204 3561

Nominal Efficiency EER / COP 3.4 / 3.7 3.62 / 3.61 3.4 / 3.7 3.62 / 3.61Energy Label A / A A / A A / A A / AAnnual Energy Consumption kWh 1000 1315 1000 1315

Air Flow Rate High / Low m3/min 18 / 14 26 / 19 18 / 14 26 / 19Dimensions Height mm 290 340 290 340

Width mm 1050 1200 1050 1200Depth mm 238 240 238 240

Weight kg 13 17 13 17Sound Pressure High / Low dBA 45 / 40 49 / 41 45 / 40 49 / 41Sound Power dBA 58 62 58 62

Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG71L8Y1 RZQG100L8Y1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.17 10.75 3.07 4.04Starting Current A 4 4 4 4Max Fuse Size A 20 32 16 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 75 50 75

Maximum Vertical Rise m 30 30 30 30Precharged to m 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.9 4.0 2.9 4.0

Sound Pressure High dBA 48 50 48 50Sound Power dBA 64 66 64 66

Trade Fan Coil Price £799.00 £863.00 £799.00 £863.00Trade Condensing Unit Price £1,191.00 £1,514.00 £1,227.00 £1,584.00Total System Price £1,990.00 £2,377.00 £2,026.00 £2,447.00

Features:• Fan speed: 3 fan speeds available on all capacities• Automatic airflow volume control sets fan speed based on difference between set and room temperatures• Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature• Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)• Selectable evaporating & condensing temperature for greater operating efficiency and application flexibility (Seasonal Smart)• DIII net compatibility as standard• Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology • Re-use of existing R22 and R407C piping possible. (See R22 Replacement leaflet)• Suitable for Twin, Triple and Double Twin applications

Accessory Ref Description Trade PriceBRC7EB518 Wireless remote controller £152.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00 KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 KRCS01-4 Remote room mounted temperature sensor £47.00 K.RSS Wireless room mounted temperature sensor and receiver £89.00 RS-SE Service and Configuration Tool for K.RSS £93.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

ii) BRC7EB518 Trade price will be reduced by £76.00 if ordered instead of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) Minimum ambient operating temperatures:

Cooling HeatingRZQG -15°C -20°CRZQSG -15°C -15°C

Page 13: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 11

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Wall Mounted – Seasonal Classic Inverter FAQ-C / RZQSG

Indoor Units Single Phase 3 PhaseFAQ71C FAQ100C FAQ100C

Capacity UK Total Cooling kW 7.28 10.80 10.80UK Sensible Cooling kW 4.99 7.44 7.44Nominal Cooling kW 6.80 9.50 9.50Nominal Heating kW 7.50 10.80 10.80

Seasonal Efficiency (EN14825) COOLING

Energy Label A+ A+ A+ Pdesign kW 6.80 9.50 9.50SEER 6.05 5.61 5.61Annual Energy Consumption kWh 393 592 592

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A+ A+Pdesign kW 6.00 6.81 6.81SCOP 3.90 4.01 4.01Annual Energy Consumption kWh 2155 2377 2377

Nominal Efficiency EER / COP 3.21 / 3.61 3.01 / 3.41 3.01 / 3.41Energy Label A / A B / B B / BAnnual Energy Consumption kWh 1059 1580 1580

Air Flow Rate High / Low m3/min 18 / 14 26 / 19 26 / 19Dimensions Height mm 290 340 340

Width mm 1050 1200 1200Depth mm 238 240 240

Weight kg 13 17 17Sound Pressure High / Low dBA 45 / 40 49 / 41 49 / 41Sound Power dBA 58 62 62

Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG100L8Y1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 990 x 940 x 320Weight kg 67 81 82Electrical Details Power Supply 1ph 3ph

Running Current A 8.66 12.91 4.86Starting Current A 4 4 4Max Fuse Size A 20 32 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 50 50

Maximum Vertical Rise m 30 30 30Precharged to m 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.75 2.9 2.9

Sound Pressure High dBA 49 53 53Sound Power dBA 65 69 69

Trade Fan Coil Price £799.00 £863.00 £863.00Trade Condensing Unit Price £881.00 £1,220.00 £1,257.00Total System Price £1,680.00 £2,083.00 £2,120.00

Page 14: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial12

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Floor Mounted – InverterNexura

Indoor Units FVXG25K FVXG35K FVXG50KCapacity UK Total Cooling kW 2.44 3.42 4.81

UK Sensible Cooling kW 1.93 2.37 3.17Nominal Cooling kW 2.50 3.50 5.00Nominal Heating kW 3.40 4.50 5.80

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A+Pdesign kW 2.50 3.50 5.00SEER 6.53 6.48 5.41Annual Energy Consumption kWh 134 189 324

Seasonal Efficiency (EN14825) HEATING

Energy Label A++ A+ A+Pdesign kW 2.80 3.10 4.60SCOP 4.65 4.00 4.18Annual Energy Consumption kWh 842 1087 1543

Nominal Efficiency EER / COP TBC / TBC TBC / TBC TBC / TBCEnergy Label TBC / TBC TBC / TBC TBC / TBCAnnual Energy Consumption kWh TBC TBC TBC

Air Flow Rate High / Low m3/min 8.9 / 5.3 9.1 / 5.3 10.6 / 7.3Dimensions Height mm 600 600 600

Width mm 950 950 950Depth mm 215 215 215

Weight kg 22 22 22Sound Pressure High / Low dBA 38 / 26 39 / 27 44 / 36Sound Power dBA 52 52 58

Outdoor Units RXG25L RXG35L RXG50LDimensions Height x Width x Depth mm 550 x 765 x 300 735 x 825 x 315Weight kg 34 34 48Electrical Details Power Supply 1ph

Running Current A 2.9* 4.6* 6.7*Starting Current A 4.4 5.5 7.4Max Fuse Size A 10 10 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2Pipework Maximum Length m 20 20 30

Maximum Vertical Rise m 15 15 20Precharged to m 10 10 10Additional Charge g/m 20Holding Charge kg 1.05 1.05 1.60

Sound Pressure High dBA 46 48 48Sound Power dBA 61 63 63

Trade Fan Coil Price £631.00 £679.00 £744.00Trade Condensing Unit Price £504.00 £585.00 £936.00Total System Price £1,135.00 £1,264.00 £1,680.00

Features:• Radiant Heat panel provides radiator-like warming at the touch of a button• Energy efficient units: full range A class energy labels• Wireless remote controller provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 4 actions per day• Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room• Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting• Extremely quiet in operation: down to 19dBA sound pressure level• Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops,

so you can sleep more comfortably• Vertical auto swing system automatically makes the louvers move up and down, creating an even distribution of air through the room to

ensure a harmonized temperature• Flexible installation: Can be installed against a wall, recessed or standing on the floor (installation leg required, see accessories list).

Ideal for installation beneath a window• Suitable for multi model applications• Re-use of existing R22 and R407 piping possible

Accessory Ref Description Trade PriceBRC944 Optional Wired Remote controller £64.00 BRCW901A03 3m connection cable for BRC944 £17.00 BRCW901A08 8m connection cable for BRC944 £22.00 KRP413A1S Adaptor PCB for remote on/off control - constant/pulse contact £75.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £132.00 KLIC-DD KNX interface for Split type systems £164.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £151.00 BKS028 Leg for floor-standing installation £393.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Accessories: Notes:i) Data marked * is provisional

ii) All fan coils supplied as standard with infrared remote controller

iii) All fan coil units standard with auto restart after power failure

iv) Wired controller, KLIC-DI and RTD-RA options cannot be combined

v) Minimum ambient operating temperatures:

Cooling HeatingRXG -10°C -15°C

Page 15: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 13

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Floor Mounted – InverterFVXS

Indoor Units FVXS25F FVXS35F FVXS50FCapacity UK Total Cooling kW 2.44 3.42 4.89

UK Sensible Cooling kW 1.87 2.34 3.21Nominal Cooling kW 2.50 3.50 5.00Nominal Heating kW 3.40 4.50 5.80

Seasonal Efficiency (EN14825) COOLING

Energy Label A+ A+ A+Pdesign kW 2.50 3.50 5.00SEER 5.74 5.60 5.89Annual Energy Consumption kWh 152 219 297

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A APdesign kW 2.60 2.90 4.20SCOP 4.56 3.93 3.80Annual Energy Consumption kWh 798 1033 1546

Nominal Efficiency EER / COP 4.39 / 4.42 3.43 / 3.78 3.23 / 3.63Energy Label A / A A / A A / AAnnual Energy Consumption kWh 285 510 775

Air Flow Rate High / Low m3/min 8.2 / 4.8 8.5 / 4.9 10.7 / 7.8Dimensions Height mm 600 600 600

Width mm 700 700 700Depth mm 210 210 210

Weight kg 14 14 14Sound Pressure High / Low dBA 38 / 26 39 / 27 44 / 36Sound Power High dBA 52 52 60

Outdoor Units RXS25L RXS35L RXS50LDimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300Weight kg 34 34 47Electrical Details Power Supply 1ph

Running Current A 3.30 4.70 6.80Starting Current A 3.3 4.3 6.8Max Fuse Size A 10 10 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2Pipework Maximum Length m 20 20 30

Maximum Vertical Rise m 15 15 20Precharged to m 10 10 10Additional Charge g/m 20Holding Charge kg 1.0 1.2 1.7

Sound Pressure High dBA 46 48 48Sound Power High dBA 59 61 62

Trade Fan Coil Price £523.00 £564.00 £616.00Trade Condensing Unit Price £476.00 £552.00 £694.00Total System Price £999.00 £1,116.00 £1,310.00

Features:• Extremely quiet, energy efficient and can be installed against the wall or recessed• Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible• Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops• Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting• Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room• Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature• Suitable for multi model applications• Re-use of existing R22 and R407C piping possible

Accessory Ref Description Trade PriceKRP413A1S Adaptor PCB for remote on/off control - constant/pulse contact £75.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £132.00 KLIC-DD KNX interface for Split type systems £164.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £151.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Accessories: Notes:i) All fan coils supplied as standard with

infrared remote controller

ii) All fan coil units standard with auto restart after power failure

iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined

iv) Minimum ambient operating temperatures:

Cooling HeatingRXS -10°C -15°C

Page 16: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial14

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Floor Mounted – Seasonal Smart InverterFVQ-C / RZQG

Indoor Units Single Phase 3 Phase FVQ71C FVQ100C FVQ125C FVQ140C FVQ71C FVQ100C FVQ125C FVQ140C

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A+ A+ - A++ A+ A+ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 6.31 5.61 5.61 - 6.31 5.61 5.61 -Annual Energy Consumption kWh 377 592 748 - 377 592 748 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A+ A - A+ A+ A -Pdesign kW 6.33 11.30 11.30 - 6.33 11.30 11.30 -SCOP 4.05 4.20 3.87 - 4.05 4.20 3.87 -Annual Energy Consumption kWh 2188 3766 4087 - 2188 3766 4087 -

Nominal Efficiency EER / COP 3.37 / 3.64 3.81 / 4.14 3.21 / 3.7 3.21 / 3.61 3.37 / 3.64 3.81 / 4.14 3.21 / 3.7 3.21 / 3.61Energy Label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 1010 1245 1870 2085 1010 1245 1870 2085

Air Flow Rate High / Low m3/min 18 / 14 28 / 22 28 / 24 30 / 26 18 / 14 28 / 22 28 / 24 30 / 26Dimensions Height mm 1850 1850 1850 1850 1850 1850 1850 1850

Width mm 600 600 600 600 600 600 600 600Depth mm 270 350 350 350 270 350 350 350

Weight kg 39 47 47 47 39 47 47 47Sound Pressure High / Low dBA 43 / 38 50 / 44 51 / 46 53 / 48 43 / 38 50 / 44 51 / 46 53 / 48Sound Power dBA 55 62 63 65 55 62 63 65

Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940

x 3201430 x 940

x 3201430 x 940

x 3201430 x 940

x 320990 x 940

x 3201430 x 940

x 3201430 x 940

x 3201430 x 940

x 320Weight kg 78 102 102 102 80 101 101 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.26 10.18 15.29 17.04 3.11 3.83 5.75 6.41Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 64 66 67 69 64 66 67 69

Trade Fan Coil Price £1,068.00 £1,174.00 £1,296.00 £1,394.00 £1,068.00 £1,174.00 £1,296.00 £1,394.00Trade Condensing Unit Price £1,191.00 £1,514.00 £1,666.00 £1,901.00 £1,227.00 £1,584.00 £1,743.00 £2,002.00Total System Price £2,259.00 £2,688.00 £2,962.00 £3,295.00 £2,295.00 £2,758.00 £3,039.00 £3,396.00

Features:• Seasonally Efficient Inverter Technology gives up to 25% better efficiency than Inverter Technology• Vertical air flow pattern can be adjusted manually to match requirements in different sized interiors or irregularly shaped rooms• A wired BRC1E52A remote controller is mounted on the front of the unit (standard)• Controllable horizontal air-blow patterns, via remote control• Very efficient for use in rooms with high ceilings• Fan speed: 2 fan speeds can be selected, high or low• Re-use of existing R22 and R407C piping possible• Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)• Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)• DIII net compatibility as standard

Accessory Ref Description Trade PriceKRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00 KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

ii) All fan coil units standard with auto restart after power failure

iii) Minimum ambient operating temperatures:

Cooling HeatingRZQG -15°C -20°CRZQSG -15°C -15°C

Page 17: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 15

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Floor Mounted – Seasonal Classic InverterFVQ-C / RZQSG

Indoor Units Single Phase 3 PhaseFVQ71C FVQ100C FVQ125C FVQ140C FVQ100C FVQ125C FVQ140C

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A A A - A A -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 5.50 5.50 5.50 - 5.50 5.50 -Annual Energy Consumption kWh 433 604 763 - 377 604 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A A+ A - A+ A -Pdesign kW 6.33 7.60 7.60 - 7.60 7.60 -SCOP 3.86 4.01 3.85 - 4.01 3.85 -Annual Energy Consumption kWh 2296 2653 2763 - 2653 2763 -

Nominal Efficiency EER / COP 3.21 / 3.61 3.21 / 3.61 2.81 / 3.41 3.01 / 3.41 3.21 / 3.61 2.81 / 3.41 3.01 / 3.41Energy Label A / A A / A C / B B / B A / A C / B B / BAnnual Energy Consumption kWh 1059 1480 2135 2225 1480 2135 2225

Air Flow Rate High / Low m3/min 18 / 14 28 / 22 28 / 24 30 / 26 28 / 22 28 / 24 30 / 26Dimensions Height mm 1850 1850 1850 1850 1850 1850 1850

Width mm 600 600 600 600 600 600 600Depth mm 270 350 350 350 350 350 350

Weight kg 39 47 47 47 47 47 47Sound Pressure High / Low dBA 43 / 38 50 / 44 51 / 46 53 / 48 50 / 44 51 / 46 53 / 48Sound Power dBA 53 59 60 63 59 60 63

Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.66 12.10 17.45 18.19 4.55 6.56 6.84Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 50 50 50 50 50 50

Maximum Vertical Rise m 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 65 69 70 69 69 70 69

Trade Fan Coil Price £1,068.00 £1,174.00 £1,296.00 £1,394.00 £1,174.00 £1,296.00 £1,394.00Trade Condensing Unit Price £881.00 £1,220.00 £1,338.00 £1,490.00 £1,257.00 £1,378.00 £1,535.00Total System Price £1,949.00 £2,394.00 £2,634.00 £2,884.00 £2,431.00 £2,674.00 £2,929.00

Page 18: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial16

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Floor or Ceiling Mounted – Inverter FLXS

Indoor Units FLXS25B FLXS35B9 FLXS50BCapacity UK Total Cooling kW 2.44 3.34 4.82

UK Sensible Cooling kW 1.65 2.14 3.16Nominal Cooling kW 2.50 3.50 4.90Nominal Heating kW 3.40 4.00 6.10

Seasonal Efficiency (EN14825) COOLING

Energy Label A B APdesign kW 2.50 3.50 4.90SEER 5.19 4.87 5.25Annual Energy Consumption kWh 169 252 326

Seasonal Efficiency (EN14825) HEATING

Energy Label A A APdesign kW 2.50 2.90 4.20SCOP 3.80 3.80 3.80Annual Energy Consumption kWh 921 1068 1546

Nominal Efficiency EER / COP 3.85 / 3.54 3.1 / 3.57 2.85 / 3.35Energy Label A / B B / B C / CAnnual Energy Consumption kWh 325 565 860

Air Flow Rate High / Low m3/min 7.6 / 6 8.6 / 6.6 11.4 / 8.5Dimensions Height mm 490 490 490

Width mm 1050 1050 1050Depth mm 200 200 200

Weight kg 16 16 17Sound Pressure High / Low dBA 37 / 31 38 / 32 47 / 39Sound Power dBA 51 53 60

Outdoor Units RXS25L RXS35L RXS50LDimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300Weight kg 34 34 47Electrical Details Power Supply 1ph

Running Current A 3.60 5.10 7.60Starting Current A 3.3 4.3 6.8Max Fuse Size A 10 10 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2Pipework Maximum Length m 20 20 30

Maximum Vertical Rise m 15 15 20Precharged to m 10 10 10Additional Charge g/m 20Holding Charge kg 1.0 1.2 1.7

Sound Pressure High dBA 46 48 48Sound Power dBA 59 61 62

Trade Fan Coil Price £376.00 £423.00 £459.00Trade Condensing Unit Price £476.00 £552.00 £694.00Total System Price £852.00 £975.00 £1,153.00

Features:• Can be installed EITHER as ceiling mounted OR wall unit• Vertical auto swing: flaps automatically swing up and down to ensure efficient air and temperature distribution in both floor level and ceiling

suspended installation• Home Leave setting maintains pre-set temperature during periods of extended absence• Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops• Fan speed: 5 fan speeds can be selected, high to super low• Suitable for multi model applications• Re-use of existing R22 and R407C piping possible

Accessory Ref Description Trade PriceKRP413A1S Adaptor PCB for remote on/off control - constant/pulse contact £75.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £132.00 KLIC-DD KNX interface for Split type systems £164.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £151.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Accessories: Notes:i) All fan coils supplied as standard with

infrared remote controller

ii) Wired controller, KLIC-DI and RTD-RA options cannot be combined

iii) All fan coil units standard with auto restart after power failure

iv) Minimum ambient operating temperatures:

Cooling HeatingRXS -10°C -15°C

Page 19: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 17

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Accessory Ref Description Trade PriceBRC7G53 Wireless remote controller £152.00 EKRORO4 Remote on/off control interface kit £29.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock. £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV. POA KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 KRCS01-4 Remote room mounted temperature sensor £47.00 K.RSS Wireless room mounted temperature sensor and receiver £89.00 RS-SE Service and Configuration Tool for K.RSS £93.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 KDDQ50A140 Fresh air intake kit for up to 20% fresh air £158.00

Ceiling Suspended – InverterFHQ-C

Indoor Units FHQ35C FHQ50C FHQ60CCapacity UK Total Cooling kW 3.32 4.92 5.57

UK Sensible Cooling kW 2.58 3.52 3.93Nominal Cooling kW 3.40 5.00 5.70Nominal Heating kW 4.00 6.00 7.20

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A+ A+Pdesign kW 3.40 5.00 5.70SEER 6.18 5.87 6.02Annual Energy Consumption kWh 193 298 332

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A APdesign kW 3.10 4.35 4.71SCOP 4.43 3.86 3.87Annual Energy Consumption kWh 981 1578 1705

Nominal Efficiency EER / COP 3.58 / 4.08 3.18 / 3.35 3.26 / 3.32Energy Label A / A B / C A / CAnnual Energy Consumption kWh 475 785 875

Air Flow Rate High / Low m3/min 14 / 10 15 / 10 19.5 / 15Dimensions Height mm 235 235 235

Width mm 960 960 1270Depth mm 690 690 690

Weight kg 24 25 31Sound Pressure High / Low dBA 36 / 31 37 / 32 37 / 33Sound Power dBA 53 54 54

Outdoor Units RXS35L RXS50L RXS60LDimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300Weight kg 34 47 48Electrical Details Power Supply 1ph

Running Current A 4.1 7.3 7.8Starting Current A 4.3 6.8 9.4Max Fuse Size A 10 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2Pipework Maximum Length m 20 30 30

Maximum Vertical Rise m 15 20 20Precharged to m 10 10 10Additional Charge g/m 20.0Holding Charge kg 1.2 1.7 1.5

Sound Pressure High dBA 48 48 49Sound Power dBA 61 62 62

Trade Fan Coil Price £710.00 £770.00 £845.00Trade Condensing Unit Price £552.00 £694.00 £740.00Total System Price £1,262.00 £1,464.00 £1,585.00

Features:• Suitable for ceiling heights of up to 3.8m without loss of capacity• Vertical auto-swing function of flaps ensures efficient air and temperature distribution• Forced off: The optional forced off feature enables the unit to switch off automatically, for example when a window is opened• Re-use of existing R22 and R407C piping possible• Suitable for Twin, Triple and Double Twin applications

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

ii) BRC7GA53 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) Minimum ambient operating temperatures:

Cooling HeatingRXS -10°C -15°C

Page 20: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial18

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Ceiling Suspended – Seasonal Smart InverterFHQ-C Seasonal Smart

Indoor Units Single Phase 3 Phase FHQ71C FHQ100C FHQ125C FHQ140C FHQ71C FHQ100C FHQ125C FHQ140C

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A+ - A++ A++ A+ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 6.95 6.11 6.01 - 6.95 6.11 6.01 -Annual Energy Consumption kWh 342 544 698 - 342 544 698 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A++ A+ - A+ A++ A+ -Pdesign kW 7.60 11.30 14.13 - 7.60 11.30 14.13 -SCOP 4.32 4.61 4.23 - 4.32 4.61 4.23 -Annual Energy Consumption kWh 2462 3431 4676 - 2462 3431 4676 -

Nominal Efficiency EER / COP 3.82 / 4.13 4.13 / 4.42 3.52 / 3.89 3.31 / 3.63 3.82 / 4.13 4.13 / 4.42 3.52 / 3.89 3.31 / 3.63Energy Label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 890 1245 1790 2025 890 1245 1790 2025

Air Flow Rate High / Low m3/min 20.5 / 14 28 / 20 31 / 23 34 / 24 20.5 / 14 28 / 20 31 / 23 34 / 24Dimensions Height mm 235 235 235 235 235 235 235 235

Width mm 1270 1590 1590 1590 1270 1590 1590 1590Depth mm 690 690 690 690 690 690 690 690

Weight kg 32 38 38 38 32 38 38 38Sound Pressure High / Low dBA 38 / 34 42 / 34 44 / 37 46 / 38 38 / 34 42 / 34 44 / 37 46 / 38Sound Power dBA 53 56 59 60 53 56 59 60

Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 7.27 10.18 14.63 16.55 2.74 3.83 5.50 6.23Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 64 66 67 69 64 66 67 69

Trade Fan Coil Price £989.00 £1,051.00 £1,315.00 £1,563.00 £989.00 £1,051.00 £1,315.00 £1,563.00Trade Condensing Unit Price £1,191.00 £1,514.00 £1,666.00 £1,901.00 £1,227.00 £1,584.00 £1,743.00 £2,002.00Total System Price £2,180.00 £2,565.00 £2,981.00 £3,464.00 £2,216.00 £2,635.00 £3,058.00 £3,565.00

Features:• Suitable for ceiling heights of up to 3.8m without loss of capacity• Seasonally Efficient Inverter Technology gives up to 25% better efficiency

than inverter technology• Forced off: The optional forced off enables the unit to switch off

automatically, for example when a window is opened• Re-use of existing R22 and R407C piping possible

• Suitable for Twin, Triple and Double Twin applications• Comms, computer and server room cooling possible with

EDP setting (Seasonal Smart)• Selectable evaporating & condensing temperature for greater

operating efficiency (Seasonal Smart)• DIII net compatibility as standard

Accessory Ref Description Trade PriceBRC7G53 Wireless remote controller £152.00 EKRORO4 Remote on/off control interface kit £29.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00 KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 KRCS01-4 Remote room mounted temperature sensor £47.00 K.RSS Wireless room mounted temperature sensor and receiver £89.00 RS-SE Service and Configuration Tool for K.RSS £93.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00 KDDQ50A140 Fresh air intake kit for up to 20% fresh air £158.00

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

ii) BRC7GA53 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) Minimum ambient operating temperatures:

Cooling HeatingRZQG -15°C -20°CRZQSG -15°C -15°C

Page 21: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 19

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Ceiling Suspended – Seasonal Classic InverterFHQ-C Seasonal Classic

Indoor Units Single Phase 3 PhaseFHQ71C FHQ100C FHQ125C FHQ140C FHQ100C FHQ125C FHQ140C

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A+ A+ A+ - A+ A+ -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 5.61 5.61 5.61 - 5.61 5.61 -Annual Energy Consumption kWh 424 592 748 - 592 748 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A A A+ - A A+ -Pdesign kW 7.60 7.60 7.60 - 7.60 7.60 -SCOP 3.90 3.91 4.01 - 3.91 4.01 -Annual Energy Consumption kWh 2727 2721 2653 - 2721 2653 -

Nominal Efficiency EER / COP 3.46 / 4 3.21 / 3.61 2.89 / 3.62 3.01 / 3.41 3.21 / 3.61 2.89 / 3.62 3.01 / 3.41Energy Label A / A A / A C / A B / B A / A C / A B / BAnnual Energy Consumption kWh 983 1480 2075 2225 1480 2075 2225

Air Flow Rate High / Low m3/min 20.5 / 14 28 / 20 31 / 23 34 / 24 28 / 20 31 / 23 34 / 24Dimensions Height mm 235 235 235 235 235 235 235

Width mm 1270 1590 1590 1590 1590 1590 1590Depth mm 690 690 690 690 690 690 690

Weight kg 32 38 38 38 38 38 38Sound Pressure High / Low dBA 38 / 34 42 / 34 44 / 37 46 / 38 42 / 34 44 / 37 46 / 38Sound Power dBA 53 56 59 60 56 59 60

Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.05 12.10 16.96 18.19 4.52 6.34 6.80Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 50 50 50 50 50 50

Maximum Vertical Rise m 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 65 69 70 69 69 70 69

Trade Fan Coil Price £989.00 £1,051.00 £1,315.00 £1,563.00 £1,051.00 £1,315.00 £1,563.00Trade Condensing Unit Price £881.00 £1,220.00 £1,338.00 £1,490.00 £1,257.00 £1,378.00 £1,535.00Total System Price £1,870.00 £2,271.00 £2,653.00 £3,053.00 £2,308.00 £2,693.00 £3,098.00

Page 22: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial20

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Indoor Units Single Phase 3 PhaseAHQ71C AHQ100C AHQ125C AHQ140C AHQ100C AHQ125C AHQ140C

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.10 13.00 9.50 12.10 13.00Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label B B - - B - -Pdesign kW 6.80 9.50 - - 9.50 - -SEER 4.65 4.60 - - 4.60 - -Annual Energy Consumption kWh 511 723 - - 723 - -

Seasonal Efficiency (EN14825) HEATING

Energy Label A A - - A - -Pdesign kW 6.33 7.60 - - 7.60 - -SCOP 3.80 3.80 - - 3.80 - -Annual Energy Consumption kWh 2332 2800 - - 2800 - -

Nominal Efficiency EER / COP 3.03 / 3.05 2.62 / 3.41 2.63 / 3.61 3.01 / 3.41 2.62 / 3.41 2.63 / 3.61 3.01 / 3.41Energy Label B / D D / B D / A B / B D / B D / A B / BAnnual Energy Consumption kWh 1120 1810 2300 2159 1810 2300 2159

Air Flow Rate High / Low m3/min 23.8 / 18.9 31.1 / 24.8 34.4 / 27.2 43.9 / 28.3 31.1 / 24.8 34.4 / 27.2 43.9 / 28.3Dimensions Height mm 260 260 260 285 260 260 285

Width mm 1320 1538 1786 1902 1538 1786 1902Depth mm 634 634 634 680 634 634 680

Weight kg 38 45 54 70 45 54 70Sound Pressure High / Low dBA 49 / 46 51 / 45 52 / 47 53 / 47 51 / 45 52 / 47 53 / 47Sound Power dBA 52 73 73 75 73 73 75

Outdoor Units AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 AZQS100BY1 AZQS125BY1 AZQS140BY1Dimensions Height x Width x Depth mm 770x900x320 990x940x320 1430x940x320 990x940x320 1430x940x320Weight kg 67 81 102 81 101Electrical Details Power Supply 1~ 3~

Running Current A 9.11 14.79 18.80 17.66 4.92 6.25 5.87Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 30 50 50 50 50 50 50

Maximum Vertical Rise m 15 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m data-book data-bookHolding Charge kg data-book data-book data-book data-book data-book data-book data-book

Sound Pressure High dBA 48 53 54 53 53 54 53Sound Power dBA 64 70 71 70 70 71 70

Trade Fan Coil Price £665.00 £756.00 £950.00 £1,098.00 £756.00 £950.00 £1,098.00Trade Condensing Unit Price £857.00 £1,019.00 £1,122.00 £1,280.00 £1,067.00 £1,174.00 £1,347.00Total System Price £1,522.00 £1,775.00 £2,072.00 £2,378.00 £1,823.00 £2,124.00 £2,445.00

Ceiling Suspended – InverterAHQ-C / AZQS

Features:• Hard wired remote ARCWB as standard• Long airflow • 3 step fan speed and auto mode• Turbo mode to quickly heat / cool room• Ideal for rooms with solid or high ceilings

Accessory Ref Description Trade PriceR04084124324 PCB Adaptor for group control (1 per fan-coil) £82.00UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories: Notes:i) Fan-coils supplied with both ARCWB hard

wired remote & infra-red remote

ii) Replacement Technology not applicable to AZQS

iii) All fan coil units standard with auto restart after power failure

iv) Minimum ambient operating temperature:

Cooling HeatingAZQS -5°C -15°C

Page 23: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 21

SPLI

T, S

KY

AIR

HEA

T PU

MPS

600x600 Fully Flat CassetteFFQ

Features:• Installed into suspended ceiling grids without cutting surrounding tiles• Home Leave setting maintains pre-set temperature during periods of extended absence• Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature• Vertical auto-swing function: flaps automatically swing up and down to ensure efficient air and temperature distribution which also prevents ceiling soiling• 3 fan speeds can be selected: high, medium and low• Suitable for Twin, Triple and Double Twin applications. Also suitable for multi model applications• Re-use of existing R22 and R407C piping possible

Accessory Ref Description Trade PriceBYFQ60CW Fully Flat Cassette Decoration Panel - White £198.00 BYFQ60CS Fully Flat Cassette Decoration Panel - Sliver £198.00 BYFQ60B3 Fully Flat Cassette Decoration Panel - Old Style (FFQ-B9V looks) £170.00BRYQ60AW Integral PIR Sensor for Fully Flat cassette White decoration panel. Enables Energy Saving functions £99.00 BRYQ60AS Integral PIR Sensor for Fully Flat Cassette Silver decoration panel. Enables Energy Saving functions £99.00 BRC7F530W Wireless remote controller for White Ceiling Decoration Panel £152.00 BRC7F530S Wireless remote controller for Silver Ceiling Decoration Panel £152.00 BRC7EB530W Wireless remote for Fully Flat Cassette Old Style Decoration Panel £152.00 BDBHQ44C60 Sealing member for decoration panel-FFQ,FXZQ £91.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 KRP1B57/UK.FB2 Adaptor PCB for Interlock to fresh air fan £100.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00 KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 KRCS01-4 Remote room mounted temperature sensor £47.00 K.RSS Wireless room mounted temperature sensor and receiver £89.00 RS-SE Service and Configuration Tool for K.RSS £93.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

i) Infrared remote Trade price will be reduced by £76.00 if ordered instead of BRC1E52A

ii) All fan coil units standard with auto restart after power failure

iv) All fan coils suppled as standard with BYFQ60CW White fully flat decoration panel

v) Minimum ambient operating temperatures:

Cooling HeatingRXS -10°C -15°C

Indoor Units FFQ25C FFQ35C FFQ50C FFQ60CCapacity UK Total Cooling kW 2.44 3.32 4.62 5.72

UK Sensible Cooling kW 1.81 2.28 3.40 4.20Nominal Cooling kW 2.50 3.40 4.70 5.80Nominal Heating kW 3.20 4.00 5.50 7.00

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A+ A+Pdesign kW 2.50 3.40 5.00 5.80SEER 6.11 6.32 5.93 5.71Annual Energy Consumption kWh 143 188 295 349

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A+ A A+Pdesign kW 2.31 3.10 3.84 3.96SCOP 4.24 4.10 3.90 4.04Annual Energy Consumption kWh 763 1059 1378 1373

Nominal Efficiency EER / COP 4.46 / 3.9 3.7 / 3.5 3.21 / 3.49 3.02 / 3.41Energy Label A / A A / B A / B B / BAnnual Energy Consumption kWh 280 460 780 945

Air Flow Rate High / Low m3/min 9 / 6.5 10 / 6.5 12 / 7.5 14.5 / 9.5Dimensions (with Decoration Panel)

Height mm 260 (306) 260 (306) 260 (306) 260 (306)Width mm 575 (620) 575 (620) 575 (620) 575 (620)Depth mm 575 (620) 575 (620) 575 (620) 575 (620)

Weight (with Decoration Panel) kg 17.5 (20.2) 17.5 (20.2) 17.5 (20.2) 17.5 (20.2)Sound Pressure High / Low dBA 31 / 25 34 / 25 39 / 27 43 / 32Sound Power dBA 48 51 56 60

Outdoor Units RXS25L RXS35L RXS50L RXS60LDimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300Weight kg 34 34 47 48Electrical Details Power Supply 1ph

Running Current A 4.00 4.00 6.90 8.30Starting Current A 3.3 4.3 6.8 9.4Max Fuse Size A 10 10 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2Pipework Maximum Length m 20 20 30 30

Maximum Vertical Rise m 15 15 20 20Precharged to m 10 10 10 10Additional Charge g/m 20Holding Charge kg 1.0 1.2 1.7 1.5

Sound Pressure High dBA 46 48 48 49Sound Power dBA 61 61 62 62

Trade Fan Coil Price £663.00 £727.00 £802.00 £849.00Trade Condensing Unit Price £476.00 £552.00 £694.00 £740.00Total System Price £1,139.00 £1,279.00 £1,496.00 £1,589.00

Page 24: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial22

SPLI

T, S

KY

AIR

HEA

T PU

MPS

High COP Roundflow Cassette – Seasonal Smart Inverter FCQHG / RZQG

Indoor Units Single Phase 3 Phase FCQHG71F FCQHG100F FCQHG125F FCQHG140F FCQHG71F FCQHG100F FCQHG125F FCQHG140F

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A++ - A++ A++ A++ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 7.00 7.00 6.61 - 7.00 7.00 6.61 -Annual Energy Consumption kWh 340 475 635 - 340 475 635 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A++ A++ - A+ A++ A++ -Pdesign kW 7.60 11.30 12.66 - 7.60 11.30 12.66 -SCOP 4.54 4.80 4.63 - 4.54 4.80 4.63 -Annual Energy Consumption kWh 2343 3295 3829 - 2343 3295 3829 -

Nominal Efficiency EER / COP 4.09 / 4.8 4.42 / 4.99 4 / 4.4 3.35 / 4.12 4.09 / 4.8 4.42 / 4.99 4 / 4.4 3.35 / 4.14Energy Label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 830 1075 1500 2000 830 1075 1500 2000

Air Flow Rate High / Low m3/min 21.2 / 12.2 32.3 / 19 33.5 / 19.9 33.5 / 21.1 21.2 / 12.2 32.3 / 19 33.5 / 19.9 33.5 / 21.1Dimensions (with Decoration Panel)

Height mm 288(348) 288 (348) 288 (348) 288 (348) 288(348) 288 (348) 288 (348) 288 (348)Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 25 (30.4) 26 (31.4) 26 (31.4) 26 (31.4) 25 (30.4) 26 (31.4) 26 (31.4) 26 (31.4)Sound Pressure High / Low dBA 36 / 29 44 / 33 45 / 35 45 / 37 36 / 29 44 / 33 45 / 35 45 / 37Sound Power dBA 53 61 61 61 53 61 61 61

Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 6.78 8.79 12.26 16.35 2.55 3.31 4.61 6.15Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 64 66 67 69 64 66 67 69

Trade Fan Coil Price £829.00 £940.00 £1,028.00 £1,239.00 £829.00 £940.00 £1,028.00 £1,239.00Trade Condensing Unit Price £1,191.00 £1,514.00 £1,666.00 £1,901.00 £1,227.00 £1,584.00 £1,743.00 £2,002.00Total System Price £2,020.00 £2,454.00 £2,694.00 £3,140.00 £2,056.00 £2,524.00 £2,771.00 £3,241.00

Features:• The FCQHG model is designed for 2014 ErP regulations and has one of the highest COP values on the market• The unique 360° radial air pattern ensures uniform air flow and temperature distribution• Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller• Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels• Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost• Optional Fresh Air intake (up to 20%) possible• Suitable for Twin, Triple and Double Twin applications• Re-use of existing R22 and R407C piping possible• Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)• Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)• DIII net compatibility as standard

Accessory Ref Description Trade PriceBRC7FA532F Wireless remote controller £152.00 BYCQ140DG Roundflow cassette decoration panel with self cleaning filter £310.00 BYCQ140DW Roundflow cassette decoration panel - white with white louvres £160.00 BRYQ140A Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions £99.00 KDBHQ55B140 Sealing member for air discharge outlet £90.00 KDDQ55B140 1&2 Fresh air intake kit for up to 20% fresh air - 2 part kit £249.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00 KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 KRCS01-4 Remote room mounted temperature sensor £47.00 K.RSS Wireless room mounted temperature sensor and receiver £89.00 RS-SE Service and Configuration Tool for K.RSS £93.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

ii) BRC7FA532F Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) All fan coils suppled as standard with BYCQ140D Decoration panel

v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £142.00 if ordered in place of standard decoration panel

vi) Minimum ambient operating temperatures:

Cooling HeatingRZQG -15°C -20°CRZQSG -15°C -15°C

Page 25: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 23

SPLI

T, S

KY

AIR

HEA

T PU

MPS

High COP Roundflow Cassette – Seasonal Classic Inverter FCQHG / RZQSG

Indoor Units Single Phase 3 PhaseFCQHG71F FCQHG100F FCQHG125F FCQHG140F FCQHG100F FCQHG125F FCQHG140F

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A - A++ A -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 6.50 6.70 5.40 - 6.70 5.40 -Annual Energy Consumption kWh 366 496 777 - 496 777 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A+ A+ - A+ A+ -Pdesign kW 7.60 8.03 8.03 - 8.03 8.03 -SCOP 4.15 4.30 4.10 - 4.30 4.10 -Annual Energy Consumption kWh 2563 2614 2741 - 2614 2741 -

Nominal Efficiency EER / COP 3.5 / 4.1 3.7 / 4.3 3.23 / 3.75 3.21 / 3.61 3.7 / 4.3 3.23 / 3.75 3.21 / 3.61Energy Label A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 1059 1285 1855 2085 1285 1855 2085

Air Flow Rate High / Low m3/min 21.2 / 12.2 32.3 / 19 33.5 / 19.9 33.5 / 21.1 32.3 / 19 33.5 / 19.9 33.5 / 21.1Dimensions (with Decoration Panel)

Height mm 288(348) 288 (348) 288 (348) 288 (348) 288 (348) 288 (348) 288 (348)Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 25 (30.4) 26 (31.4) 26 (31.4) 26 (31.4) 26 (31.4) 26 (31.4) 26 (31.4)Sound Pressure High / Low dBA 36 / 29 44 / 33 45 / 35 45 / 37 44 / 33 45 / 35 45 / 37Sound Power dBA 53 61 61 61 61 61 61

Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 7.93 10.50 15.16 17.04 3.93 5.67 6.37Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 50 50 50 50 50 50

Maximum Vertical Rise m 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 65 69 70 69 69 70 69

Trade Fan Coil Price £829.00 £940.00 £1,028.00 £1,239.00 £940.00 £1,028.00 £1,239.00Trade Condensing Unit Price £881.00 £1,220.00 £1,338.00 £1,490.00 £1,257.00 £1,378.00 £1,535.00Total System Price £1,710.00 £2,160.00 £2,366.00 £2,729.00 £2,197.00 £2,406.00 £2,774.00

Self Cleaning PanelDaikin’s Roundflow Cassette can be equipped with a special filter that cleans itself once a day, ensuring consistent, optimum performance.

Result? Efficiency gains up to 50% compared to standard panels.*

The dust collected during daily auto-cleaning is stored in a dust box that can hold up to 12 months of dust, with an indicator light showing when to clean the dust box. Under normal circumstances, annual or bi-annual cleaning by in-house maintenance personnel using an ordinary vacuum cleaner is all that is needed: no ladders, no need to touch the cassette panel or come in contact with the dust.

* Reference: Coral, Wolverhampton case study.

Page 26: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial24

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Compact Roundflow Cassette – Seasonal Smart Inverter FCQG / RZQG

Indoor Units Single Phase 3 Phase FCQG71F FCQG100F FCQG125F FCQG140F FCQG71F FCQG100F FCQG125F FCQG140F

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A+ - A++ A++ A+ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 6.80 6.80 6.00 - 6.80 6.80 6.00 -Annual Energy Consumption kWh 350 488 700 - 350 488 700 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A++ A+ - A+ A++ A+ -Pdesign kW 6.33 11.30 12.66 - 6.33 11.30 12.66 -SCOP 4.20 4.61 4.10 - 4.20 4.61 4.10 -Annual Energy Consumption kWh 2110 3431 4322 - 2110 3431 4322 -

Nominal Efficiency EER / COP 3.39 / 3.97 3.87 / 4.15 3.73 / 3.63 3.21 / 3.61 3.39 / 3.97 3.87 / 4.15 3.73 / 3.63 3.21 / 3.61Energy Label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 1005 1225 1610 2085 1005 1225 1610 2085

Air Flow Rate High / Low m3/min 15 / 9.1 22.8 / 12.4 26 / 12.4 26 / 12.4 15 / 9.1 22.8 / 12.4 26 / 12.4 26 / 12.4Dimensions (with Decoration Panel)

Height mm 204 (264) 246 (306) 246 (306) 246 (306) 204 (264) 246 (306) 246 (306) 246 (306)Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4) 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4)Sound Pressure High / Low dBA 33 / 28 37 / 29 41 / 29 41 / 29 33 / 28 37 / 29 41 / 29 41 / 29Sound Power dBA 51 54 58 58 51 54 58 58

Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.21 10.01 13.16 17.04 3.09 3.77 4.95 6.41Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 64 66 67 69 64 66 67 69

Trade Fan Coil Price £829.00 £940.00 £1,028.00 £1,239.00 £829.00 £940.00 £1,028.00 £1,239.00Trade Condensing Unit Price £1,191.00 £1,514.00 £1,666.00 £1,901.00 £1,227.00 £1,584.00 £1,743.00 £2,002.00Total System Price £2,020.00 £2,454.00 £2,694.00 £3,140.00 £2,056.00 £2,524.00 £2,771.00 £3,241.00

Features:• FCQG is a compact cassette designed to suit installation in narrower ceiling voids• The unique 360° radial air pattern ensures uniform air flow and temperature distribution• Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller• Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels• Optional Self Cleaning Filter: The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost• Optional Fresh Air intake (up to 20%) possible• Re-use of existing R22 and R407C piping possible• Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)• Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)• DIII net compatibility as standard

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

ii) BRC7FA532F Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) All fan coils suppled as standard with BYCQ140D Decoration panel

v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £142.00 if ordered in place of standard decoration panel

vi) Minimum ambient operating temperatures:

Cooling HeatingRZQG -15°C -20°CRZQSG -15°C -15°C

Accessory Ref Description Trade PriceBRC7FA532F Wireless remote controller £152.00 BYCQ140DG Roundflow cassette decoration panel with self cleaning filter £310.00 BYCQ140DW Roundflow cassette decoration panel - white with white louvres £160.00 BRYQ140A Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions £99.00 KDBHQ55B140 Sealing member for air discharge outlet £90.00 KDDQ55B140 1&2 Fresh air intake kit for up to 20% fresh air - 2 part kit £249.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 KRCS01-4 Remote room mounted temperature sensor £47.00 K.RSS Wireless room mounted temperature sensor and receiver £89.00 RS-SE Service and Configuration Tool for K.RSS £93.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Page 27: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 25

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Compact Roundflow Cassette – Seasonal Classic Inverter FCQG / RZQSG

Indoor Units Single Phase 3 PhaseFCQG71F FCQG100F FCQG125F FCQG140F FCQG100F FCQG125F FCQG140F

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A - A++ A -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 6.10 6.50 5.30 - 6.50 5.30 -Annual Energy Consumption kWh 390 511 792 - 511 792 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A+ A+ - A+ A+ -Pdesign kW 6.33 7.60 8.03 - 7.60 8.03 -SCOP 4.10 4.10 4.01 - 4.10 4.01 -Annual Energy Consumption kWh 2162 2595 2803 - 2595 2803 -

Nominal Efficiency EER / COP 3.21 / 3.61 3.3 / 3.54 3.21 / 3.41 3.01 / 3.41 3.3 / 3.54 3.21 / 3.41 3.01 / 3.41Energy Label A / A A / B A / B B / B A / B A / B B / BAnnual Energy Consumption kWh 971 1440 1870 2225 1440 1870 2225

Air Flow Rate High / Low m3/min 15 / 9.1 22.8 / 12.4 26 / 12.4 26 / 12.4 22.8 / 12.4 26 / 12.4 26 / 12.4Dimensions (with Decoration Panel)

Height mm 204 (264) 246 (306) 246 (306) 246 (306) 246 (306) 246 (306) 246 (306)Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4)Sound Pressure High / Low dBA 33 / 28 37 / 29 41 / 29 41 / 29 37 / 29 41 / 29 41 / 29Sound Power dBA 51 54 58 58 54 58 58

Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.66 11.77 15.29 18.19 4.40 5.72 6.80Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 50 50 50 50 50 50

Maximum Vertical Rise m 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 65 69 70 69 69 70 69

Trade Fan Coil Price £829.00 £940.00 £1,028.00 £1,239.00 £940.00 £1,028.00 £1,239.00Trade Condensing Unit Price £881.00 £1,220.00 £1,338.00 £1,490.00 £1,257.00 £1,378.00 £1,535.00Total System Price £1,710.00 £2,160.00 £2,366.00 £2,729.00 £2,197.00 £2,406.00 £2,774.00

Page 28: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial26

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Compact Roundflow Cassette – Inverter FCQG / RXS

Indoor Units FCQG35F FCQG50F FCQG60FCapacity UK Total Cooling kW 3.32 4.89 5.57

UK Sensible Cooling kW 2.29 3.26 3.67Nominal Cooling kW 3.40 5.00 5.70Nominal Heating kW 4.20 6.00 7.00

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A++Pdesign kW 3.50 5.00 5.70SEER 6.35 6.48 6.22Annual Energy Consumption kWh 193 270 321

Seasonal Efficiency (EN14825) HEATING

Energy Label A++ A++ A+Pdesign kW 3.32 4.36 4.71SCOP 4.90 4.29 4.00Annual Energy Consumption kWh 949 1426 1646

Nominal Efficiency EER / COP 3.58 / 3.5 3.55 / 3.7 3.48 / 3.52Energy Label A / B A / A A / BAnnual Energy Consumption kWh 475 705 820

Air Flow Rate High / Low m3/min 12.5 / 8.7 12.6 / 8.7 13.6 / 8.7Dimensions (with Decoration Panel)

Height mm 204 (264) 204 (264) 204 (264)Width mm 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 18 (23.4) 19 (24.4) 19 (24.4)Sound Pressure High / Low dBA 31 / 27 31 / 27 33 / 28Sound Power dBA 49 49 51

Outdoor Units RXS35L RXS50L RXS60LDimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300Weight kg 34 47 48Electrical Details Power Supply 1ph

Running Current A 4.00 6.30 7.40Starting Current A 4.30 6.80 9.40Max Fuse Size A 10 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2Pipework Maximum Length m 20 30 30

Maximum Vertical Rise m 15 20 20Precharged to m 10 10 10Additional Charge g/m 20 20 20Holding Charge kg 1.2 1.7 1.5

Sound Pressure High dBA 48 48 49Sound Power dBA 61 62 62

Trade Fan Coil Price £718.00 £735.00 £782.00Trade Condensing Unit Price £552.00 £694.00 £740.00Total System Price £1,270.00 £1,429.00 £1,522.00

Features:• FCQG is a compact cassette designed to suit installation in narrower ceiling voids• The unique 360° radial air pattern ensures uniform air flow and temperature distribution• Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller• Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels• Optional Self Cleaning Filter: The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost• Suitable for Twin, Triple and Double Twin applications• Re-use of existing R22 and R407C piping possible• DIII net compatibility as standard

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

ii) BRC7FA532F Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) All fan coils suppled as standard with BYCQ140D Decoration panel

v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £142.00 if ordered in place of standard decoration panel

vi) Minimum ambient operating temperatures:

Cooling HeatingRXS -10°C -15°C

Accessory Ref Description Trade PriceBRC7FA532F Wireless remote controller £152.00 BYCQ140DG Roundflow cassette decoration panel with self cleaning filter £310.00 BYCQ140DW Roundflow cassette decoration panel - white with white louvres £160.00 BRYQ140A Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions £99.00 KDBHQ55B140 Sealing member for air discharge outlet £90.00 KDDQ55B140 1&2 Fresh air intake kit for up to 20% fresh air - 2 part kit £249.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00 KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 KRCS01-4 Remote room mounted temperature sensor £47.00 K.RSS Wireless room mounted temperature sensor and receiver £89.00 RS-SE Service and Configuration Tool for K.RSS £93.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Page 29: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 27

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Indoor Units Single Phase 3 PhaseACQ71C ACQ100C ACQ125C ACQ100C ACQ125C

Capacity UK Total Cooling kW 7.28 10.80 13.60 10.80 13.60UK Sensible Cooling kW 4.99 7.44 9.30 7.44 9.30Nominal Cooling kW 6.80 9.50 12.10 9.50 12.10Nominal Heating kW 7.50 10.80 13.50 10.80 13.50

Seasonal Efficiency (EN14825) COOLING

Energy Label B B - B -Pdesign kW 6.33 9.50 - 9.50 -SEER 4.65 4.65 - 4.65 -Annual Energy Consumption kWh 476 716 - 716 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A A - A -Pdesign kW 6.33 7.60 - 7.60 -SCOP 3.80 3.80 - 3.80 -Annual Energy Consumption kWh 2332 2800 - 2800.00 -

Nominal Efficiency EER / COP 3.31/3.61 3.21/3.61 3.01/3.41 3.21/3.61 3.01/3.41Energy Label A/A A/A - A/A -Annual Energy Consumption kWh 1027 1480 2010 1480.00 2010.00

Air Flow Rate High / Low m3/min 24.4 / 17.6 29.2 / 21.0 34.0 / 26.3 29.2 / 21.0 34.0 / 26.3Dimensions (with Decoration Panel)

Height mm 265 (347) 300 (382) 300 (382) 300 (382) 300 (382)Width mm 820 (990) 820 (990) 820 (990) 820 (990) 820 (990)Depth mm 820 (990) 820 (990) 820 (990) 820 (990) 820 (990)

Weight (with Decoration Panel) kg 31 (35) 39 (43) 39 (43) 39 (43) 39 (43)Sound Pressure High / Low dBA 41 / 35 44 / 38 47 / 43 44 / 38 47 / 43Sound Power dBA 50 54 56 54.00 56.00

Outdoor Units AZQS71BV1 AZQS100BV1 AZQS120BV1 AZQS100BY1 AZQS125BY1Dimensions Height x Width x Depth mm 770X900X320 990X940X320 990X940X320Weight kg 67 81 82Electrical Details Power Supply 1~ 3~

Running Current A 8.38 12.10 16.43 4.02 5.46Starting Current A 4 4 4 4 4Max Fuse Size A 20 32 32 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 30 50 50 50 50

Maximum Vertical Rise m 15 15 15 15 15Precharged to m 30 30 30 30 30Additional Charge g/m Databook DatabookHolding Charge kg Databook Databook

Sound Pressure High dBA 48 53 54 53 54Sound Power dBA 64 70 71 70 71

Trade Fan Coil Price £644.00 £749.00 £836.00 £749.00 £836.00Trade Condensing Unit Price £857.00 £1,019.00 £1,122.00 £1,067.00 £1,174.00Total System Price £1,501.00 £1,768.00 £1,958.00 £1,816.00 £2,010.00

4-Way Blow Cassette – InverterACQ-B/AZQS

Features:• 4-way blow cassette• Hard wired remote ARCWB as standard• 7 day timer• Knock out for connection to branch duct• Auto swing mode for better air distribution• Suitable for rooms with suspended ceilings

Accessory Ref Description Trade PriceR04084124324 PCB Adaptor for group control (1 per fan-coil) £82.00UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories: Notes:i) Fan-coils supplied with both ARCWB hard

wired remote & infra-red remote

ii) Replacement Technology not applicable to AZQS

iii) All fan coils suppled as standard with ADP125A Decoration panel

iv) All fan coil units standard with auto restart after power failure

v) Minimum ambient operating temperature:

Cooling HeatingAZQS -5°C -15°C

Page 30: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial28

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Under Ceiling Cassette – Seasonal Smart Inverter FUQ-C / RZQG

Indoor Units Single Phase 3 Phase FUQ71C FUQ100C FUQ125C FUQ71C FUQ100C FUQ125C

Capacity UK Total Cooling kW 7.76 10.80 13.60 7.76 10.80 13.60UK Sensible Cooling kW 5.32 7.44 9.30 5.32 7.44 9.30Nominal Cooling kW 6.80 9.50 12.00 6.80 9.50 12.00Nominal Heating kW 7.50 10.80 13.50 7.50 10.80 13.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A++ A+ A++ A++ A+ Pdesign kW 6.80 9.50 12.00 6.80 9.50 12.00SEER 6.50 6.11 5.61 6.50 6.11 5.61Annual Energy Consumption kWh 366 544 748 366 544 748

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A+ A+ A+ A+ A+Pdesign kW 7.60 11.30 14.13 7.60 11.30 14.13SCOP 4.20 4.50 4.44 4.20 4.50 4.44Annual Energy Consumption kWh 2533 3517 4456 2533 3515 4456

Nominal Efficiency EER / COP 4.07 / 4.47 4.08 / 4.04 3.4 / 4.04 4.07 / 4.47 4.08 / 4.04 3.4 / 4.04Energy Label A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 840 1230 1770 840 1230 1770

Air Flow Rate High / Low m3/min 23 / 16 31 / 20 32.5 / 20.5 23 / 16 31 / 20 32.5 / 20.5Dimensions Height mm 198 198 198 198 198 198

Width mm 950 950 950 950 950 950Depth mm 950 950 950 950 950 950

Weight kg 25 26 26 25 26 26Sound Pressure High / Low dBA 41 / 35 46 / 39 47 / 40 41 / 35 46 / 39 47 / 40Sound Power dBA 59 64 65 59 64 65

Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 6.83 9.52 14.06 2.57 3.58 5.29Starting Current A 4 4 4 4 4 4Max Fuse Size A 20 32 32 16 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 75 75 50 75 75

Maximum Vertical Rise m 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.9 4.0 4.0 2.9 4.0 4.0

Sound Pressure High dBA 48 50 51 48 50 51Sound Power dBA 64 66 67 64 66 67

Trade Fan Coil Price £915.00 £1,004.00 £1,109.00 £915.00 £1,004.00 £1,109.00Trade Condensing Unit Price £1,191.00 £1,514.00 £1,666.00 £1,227.00 £1,584.00 £1,743.00Total System Price £2,106.00 £2,518.00 £2,775.00 £2,142.00 £2,588.00 £2,852.00

Features:• The 4-way blow under ceiling cassettes are the ideal solution for rooms, shops or offices without false ceilings• Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology• Air flow flexibility: air can be discharged in any of 4 directions. Possibility to shut off 1 or 2 flaps enabling the unit

to be installed in a corner or small room• 3 step fan-speed• Suitable for Twin, Triple and Double Twin applications• Re-use of existing R22 and R407C piping possible• Comms, computer and server room cooling possible with EDP setting• Selectable evaporating & condensing temperature for greater operating efficiency

Accessory Ref Description Trade PriceBRC7C58 Wireless remote controller £152.00 EKRORO5 Remote on/off control interface kit £29.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00 KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 KRCS01-4 Remote room mounted temperature sensor £47.00 K.RSS Wireless room mounted temperature sensor and receiver £89.00 RS-SE Service and Configuration Tool for K.RSS £93.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

ii) BRC7C58 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) Minimum ambient operating temperatures:

Cooling HeatingRZQG -15°C -20°C

Page 31: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 29

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Built in DC Ducted & Slim Ducted – Inverter FBQ & FDXS-F / RXS

Indoor Units DC Ducted Slim DuctedFBQ35C8 FBQ50C8 FBQ60C8 FDXS25F FDXS35F FDXS50F9 FDXS60F

Capacity UK Total Cooling kW 3.32 4.89 5.57 2.35 3.32 4.81 5.86UK Sensible Cooling kW 2.93 3.60 4.10 1.81 2.26 3.08 3.97Nominal Cooling kW 3.50 5.90 5.70 2.40 3.40 5.00 6.00Nominal Heating kW 4.00 5.50 7.00 3.20 4.00 5.80 7.00

Seasonal Efficiency (EN14825) COOLING

Energy Label A+ A+ A+ A+ A A+ APdesign kW 3.50 4.90 5.70 2.40 3.40 5.00 6.00SEER 5.97 5.85 5.72 5.63 5.21 5.72 5.51Annual Energy Consumption kWh 205 293 349 149 228 306 381

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A A A+ A A APdesign kW 2.90 4.35 4.60 2.60 2.90 4.00 4.60SCOP 3.93 3.85 3.80 4.24 3.88 3.93 3.80Annual Energy Consumption kWh 1033 1584 1693 858 1047 1425 1693

Nominal Efficiency EER / COP 3.21 / 3.6 3.03 / 3.42 3.26 / 3.41 3.69 / 4 3.21 / 3.48 3.03 / 3.1 2.91 / 3.21Energy Label A / A B / B A / B A / A A / B B / D C / CAnnual Energy Consumption kWh 530 825 875 325 530 825 1030

Air Flow Rate High / Low m3/min 16 / 11 16 / 11 18 / 15 8.7 / 7.3 8.7 / 7.3 12 / 10 16 / 13.5Dimensions Height mm 300 300 300 200 200 200 200

Width mm 700 700 1000 700 700 1150 1100Depth mm 700 700 700 620 620 620 620

Weight kg 25 25 34 21 21 30 30Sound Pressure High / Low dBA 32 / 27 37 / 29 37 / 30 35 / 31 35 / 31 37 / 33 38 / 34Sound Power dBA 50 55 55 53 53 55 56

Outdoor Units RXS35L RXS50L RXS60L RXS25L RXS35L RXS50L RXS60LDimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300Weight kg 34 47 48 34 34 47 48Electrical Details Power Supply 1ph - see notes 1ph 1ph

Running Current A 4.6* 7.2* 9.2* 3.90 4.90 7.10 9.20Starting Current A 4.3 6.8 9.4 3.3 4.3 6.8 9.4Max Fuse Size A 10 20 20 10 10 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5 3+E / 1.5 3+E / 2.5Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2Pipework Maximum Length m 20 30 30 20 20 30 30

Maximum Vertical Rise m 15 20 20 15 15 20 20Precharged to m 10 10 10 10 10 10 10Additional Charge g/m 20 20Holding Charge kg 1.2 1.7 1.5 1.0 1.2 1.7 1.5

Sound Pressure High dBA 48 48 49 46 48 48 49Sound Power dBA 61 62 62 59 61 62 62

Trade Fan Coil Price £547.00 £575.00 £639.00 £394.00 £441.00 £477.00 £524.00Trade Condensing Unit Price £552.00 £694.00 £740.00 £476.00 £552.00 £694.00 £740.00Total System Price £1,099.00 £1,269.00 £1,379.00 £870.00 £993.00 £1,171.00 £1,264.00

Accessory Ref Description Applicable Units Trade PriceBRC4C65 Wireless remote controller FBQ / FDXS £152.00 BRC2C51 Wired Simplified remote controller (without auto swing) FBQ / FDXS £90.00 EKRORO3 Remote on/off control interface kit FBQ £29.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting FBQ / FDXS £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV FBQ / FDXS £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock FBQ / FDXS £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV FBQ / FDXS £251.00KLIC-DI KNX Interface for Sky Air and VRV systems FBQ / FDXS £185.00 KRCS01-4 Remote room mounted temperature sensor FBQ / FDXS £47.00 K.RSS Wireless room mounted temperature sensor and receiver FBQ / FDXS £89.00 RS-SE Service and Configuration Tool for K.RSS FBQ / FDXS £93.00 BYBS45D Return air suction grille FBQ35~50 £121.00 BYBS71D Return air suction grille FBQ60 £159.00 UK.RAC2 Return Air Chamber, 2 x 200mm dia FBQ35~50 £79.00 UK.RAC3 Return Air Chamber, 2 x 200mm dia FBQ60 £86.00 UK.RAC3A Return Air Chamber, 3 x 200mm dia FBQ60 £93.00 UK.RAC5 Return Air Chamber, 2 x 150mm dia FDXS25~35 £76.00 UK.RAC6 Return Air Chamber, 3 x 150mm dia FDXS50 £83.00 UK.RAC7 Return Air Chamber, 4 x 150mm dia FDXS60~71 £97.00 UK.SAF2 Supply Air Flange 2 x 200mm dia FBQ35~50 £72.00 UK.SAF3 Supply Air Flange 2 x 200mm dia FBQ60 £79.00 UK.SAF3A Supply Air Flange 3 x 200mm dia FBQ60 £84.00 UK.SAF5 Supply Air Flange 2 x 150mm dia FDXS25~35 £67.00 UK.SAF6 Supply Air Flange 3 x 150mm dia FDXS50 £73.00 UK.SAF7 Supply Air Flange 4 x 150mm dia FDXS60~71 £85.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGS Condensing Unit Guard size 20-35 £214.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Accessories: Notes:i) FBQ & FDXS fan coils supplied as standard

with BRC1E52A wired remote controller with 7-day time clock

ii) BRC4C65 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) All fan coils supplied as standard with air filter

v) Minimum ambient operating temperatures:

vi) FBQ35C8 Fan Coil unit requires a separate 1ph 5 amp power supply

Cooling HeatingRXS -10°C -15°C

Features:• Fan speed: 5 fan speeds can be selected, high to super low • Connection to multi outdoor possible • Re-use of existing R22 and R407C piping possible

Page 32: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial30

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Built in DC Ducted – Seasonal Smart Inverter FBQ / RZQG

Indoor Units Single Phase 3 Phase FBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8 FBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A++ A+ A+ - A++ A+ A+ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 6.11 5.80 5.81 - 6.11 5.80 5.81 -Annual Energy Consumption kWh 389 573 722 - 389 573 722 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A++ A+ - A+ A++ A+ -Pdesign kW 6.00 11.30 12.71 - 6.00 11.30 12.71 -SCOP 4.01 4.61 4.21 - 4.01 4.61 4.21 -Annual Energy Consumption kWh 2094 3431 4226 - 2094 3431 4226 -

Nominal Efficiency EER / COP 3.5 / 3.65 3.89 / 4.21 3.81 / 3.83 3.33 / 3.61 3.5 / 3.65 3.89 / 4.21 3.81 / 3.83 3.33 / 3.61Energy Label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 970 1220 1575 2010 970 1220 1575 2010

Air Flow Rate High / Low m3/min 18 / 15 32 / 23 39 / 28 39 / 28 18 / 15 32 / 23 39 / 28 39 / 28Dimensions Height mm 300 300 300 300 300 300 300 300

Width mm 1000 1400 1400 1400 1000 1400 1400 1400Depth mm 700 700 700 700 700 700 700 700

Weight kg 34 45 45 45 34 45 45 45Sound Pressure High / Low dBA 37 / 29 38 / 32 40 / 33 40 / 33 37 / 29 38 / 32 40 / 33 40 / 33Sound Power dBA 57 61 66 66 57 61 66 66

Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 7.93 9.97 12.87 16.43 2.98 3.75 4.84 6.18Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 64 66 67 69 64 66 67 69

Trade Fan Coil Price £918.00 £960.00 £1,137.00 £1,318.00 £918.00 £960.00 £1,137.00 £1,318.00Trade Condensing Unit Price £1,191.00 £1,514.00 £1,666.00 £1,901.00 £1,227.00 £1,584.00 £1,743.00 £2,002.00Total System Price £2,109.00 £2,474.00 £2,803.00 £3,219.00 £2,145.00 £2,544.00 £2,880.00 £3,320.00

Features:• The new inverter fan ducted units, provides both drastic energy savings and simplifies installation• Automatically adjusts air volume against ESP at commissioning• Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology• Comms, computer and server room cooling possible with EDP setting• Selectable evaporating & condensing temperature for greater operating efficiency

Accessory Ref Description Applicable Units Trade PriceBRC4C65 Wireless remote controller £152.00 EKRORO3 Remote on/off control interface kit £29.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock. £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV. £251.00 KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 KRCS01-4 Remote room mounted temperature sensor £47.00 K.RSS Wireless room mounted temperature sensor and receiver £89.00 RS-SE Service and Configuration Tool for K.RSS £93.00 BYBS71D Return air suction grille FBQ71 £159.00 BYBS125D Return air suction grille FBQ100~140 £198.00 EKBYBSD Mounting Kit for Decoration Panel (when installed directly onto the unit body) £28.00 UK.RAC3 Return Air Chamber, 2 x 200mm dia FBQ71 £86.00 UK.RAC3A Return Air Chamber, 3 x 200mm dia FBQ71 £93.00 UK.RAC4 Return Air Chamber, 4 x 200mm dia FBQ100~140 £116.00 UK.SAF3 Supply Air Flange 2 x 200mm dia FBQ71 £79.00 UK.SAF3A Supply Air Flange 3 x 200mm dia FBQ71 £84.00 UK.SAF4 Supply Air Flange 4 x 200mm dia FBQ100~140 £104.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories: Notes:i) All fan coils supplied as standard with

BRC1E52A wired remote controller with 7-day time clock

ii) BRC4C65 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) All fan coils supplied as standard with air filter

v) Minimum ambient operating temperatures:

Cooling HeatingRZQG -15°C -20°CRZQSG -15°C -15°C

• Fan speed: 2 fan speeds can be selected, high or low• Suitable for Twin, Triple and Double Twin applications• Re-use of existing R22 and R407C piping possible• DIII net compatibility as standard

Page 33: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 31

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Built in DC Ducted – Seasonal Classic Inverter FBQ / RZQSG

Indoor Units Single Phase 3 PhaseFBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8 FBQ100C8 FBQ125C8 FBQ140C8

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label A+ A A - A A -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 5.81 5.50 5.20 - 5.50 5.20 -Annual Energy Consumption kWh 410 604 807 - 604 807 -

Seasonal Efficiency (EN14825) HEATING

Energy Label A A+ A - A+ A -Pdesign kW 6.00 7.60 7.60 - 7.60 7.60 -SCOP 3.88 4.01 3.90 - 4.01 3.90 -Annual Energy Consumption kWh 2166 2653 2728 - 2653 2728 -

Nominal Efficiency EER / COP 3.28 / 3.61 3.31 / 3.65 3.21 / 3.51 3.02 / 3.41 3.31 / 3.65 3.21 / 3.51 3.02 / 3.41Energy Label A / A A / A A / B B / B A / A A / B B / BAnnual Energy Consumption kWh 1037 1435 1870 2220 1435 1870 2220

Air Flow Rate High / Low m3/min 18 / 15 32 / 23 39 / 28 39 / 28 32 / 23 39 / 28 39 / 28Dimensions Height mm 300 300 300 300 300 300 300

Width mm 1000 1400 1400 1400 1400 1400 1400Depth mm 700 700 700 700 700 700 700

Weight kg 34 45 45 45 45 45 45Sound Pressure High / Low dBA 37 / 29 38 / 32 40 / 33 41 / 34 38 / 32 40 / 33 41 / 34Sound Power dBA 57 61 66 66 61 66 66

Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.46 11.73 15.29 18.15 4.39 5.72 6.79Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 50 50 50 50 50 50

Maximum Vertical Rise m 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 65 69 70 69 69 70 69

Trade Fan Coil Price £918.00 £960.00 £1,137.00 £1,318.00 £960.00 £1,137.00 £1,318.00Trade Condensing Unit Price £881.00 £1,220.00 £1,338.00 £1,490.00 £1,257.00 £1,378.00 £1,535.00Total System Price £1,799.00 £2,180.00 £2,475.00 £2,808.00 £2,217.00 £2,515.00 £2,853.00

Page 34: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial32

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Concealed Ceiling UnitABQ-B/A / AZQS

Indoor Units Single Phase 3 PhaseABQ71B ABQ100A ABQ125A ABQ140A ABQ100A ABQ125A ABQ140A

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.10 13.00 9.50 12.10 13.00Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) COOLING

Energy Label B - - - - - -Pdesign kW 6.80 - - - - - -SEER 4.65 - - - - - -Annual Energy Consumption kWh 512 - - - - - -

Seasonal Efficiency (EN14825) HEATING

Energy Label A - - - - - -Pdesign kW 6.33 - - - - - -SCOP 3.41 - - - - - -Annual Energy Consumption kWh 2599 - - - - - -

Nominal Efficiency EER / COP 3.01 / 3.61 3.05 / 3.55 2.91 / 3.41 3.01 / 3.41 3.05 / 3.55 2.91 / 3.41 3.01 / 3.41Energy Label B / A B / B C / B B / B B / B C / B B / BAnnual Energy Consumption kWh 1130 tbc 2079 2159 tbc 2079.00 2159.00

Air Flow Rate High / Low m3/min 18.3 / 15.6 tbc TBC TBC tbc TBC TBCDimensions Height mm 285 305 378 378 305.00 378.00 378.00

Width mm 1007 1325 1388 1388 1325.00 1388.00 1388.00Depth mm 600 638 541 541 638.00 541.00 541.00

Weight kg 35 47 50 56 47.00 50.00 56.00Sound Pressure High / Low dBA TBC 51 / 45 52 / 47 53 / 47 51 / 45 52 / 47 53 / 47Sound Power dBA 59 73 73 75 73.00 73.00 75.00

Outdoor Units AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 AZQS100BY1 AZQS125BY1 AZQS140BY1Dimensions Height x Width x Depth mm 770x900x320 990x940x320 1430x940x320 990x940x320 1430x940x320Weight kg 67 81 102 81 101Electrical Details Power Supply 1~ 3~

Running Current A 9.24 tbc 17.00 17.66 tbc 4.16 4.32Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 30 50 50 50 50 50 50

Maximum Vertical Rise m 15 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m data-book data-bookHolding Charge kg data-book data-book data-book data-book data-book data-book data-book

Sound Pressure High dBA 48 53 54 53 53 54 53Sound Power dBA 64 70 71 70 70 71 70

Trade Fan Coil Price £632.00 £812.00 £926.00 £969.00 £812.00 £926.00 £969.00Trade Condensing Unit Price £857.00 £1,019.00 £1,122.00 £1,280.00 £1,067.00 £1,174.00 £1,347.00Total System Price £1,480.00 £1,831.00 £2,048.00 £2,249.00 £1,879.00 £2,100.00 £2,316.00

Features:• 7 day timer as standard• Hard wired remote ARCWA as standard• Ideal for shops / restaurants with ceiling voids• High external static pressures for long duct runs

Accessory Ref Description Trade PriceR04084124324 PCB Adaptor for group control (1 per fan-coil) £82.00UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories: Notes:i) Fan-coils supplied with ARCWA hard

wired remote

ii Replacement Technology not applicable to AZQS

iii) All fan coil units standard with auto restart after power failure

iv) Fan-coils supplied as standard with air filter

v) Minimum ambient operating temperature:

Cooling HeatingAZQS -5°C -15°C

Page 35: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 33

SPLI

T, S

KY

AIR

HEA

T PU

MPS

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

ii) BRC4C65 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A

iii) Replacement technology not applicable to RZQ200 and RZQ250

iv) All fan coil units standard with auto restart after power failure

v) All fan coils supplied as standard with air filter

vi) Minimum ambient operating temperatures:

vii) FDQ Fan Coil unit requires a separate 15 amp power supply

High Static Ducted – Seasonal Smart, Classic & Super Inverter FDQ

Indoor Units Single Phase 3 Phase Single Phase 3 Phase Super Inverter (3 phase)FDQ125C FDQ125C FDQ125C FDQ125C FDQ200B FDQ250B

Capacity UK Total Cooling kW 13.60 13.60 13.60 13.60 19.40 23.50UK Sensible Cooling kW 9.30 9.30 9.30 9.30 16.30 20.70Nominal Cooling kW 12.00 12.00 12.00 12.00 20.00 25.00Nominal Heating kW 13.50 13.50 13.50 13.50 23.00 27.00

Seasonal Efficiency (EN14825) COOLING

Energy Label A+ A+ A A - -Pdesign kW 12.00 12.00 12.00 12.00 - -SEER 5.81 5.81 5.20 5.20 - -Annual Energy Consumption kWh 722 722 807 807 - -

Seasonal Efficiency (EN14825) HEATING

Energy Label A+ A+ A A - -Pdesign kW 12.71 12.71 7.60 7.60 - -SCOP 4.21 4.21 3.90 3.90 - -Annual Energy Consumption kWh 4226 4226 2728 2728 - -

Nominal Efficiency EER / COP 3.75 / 3.83 3.75 / 3.83 3.21 / 3.51 3.21 / 3.51 3.21 / 3.41 2.81 / 3.21Energy Label A / A A / A A / B A / B A / B C / CAnnual Energy Consumption kWh 1600 1600 1870 1600 3115 4290

Air Flow Rate High / Low m3/min 39 / 28 39 / 28 39 / 28 39 / 28 69 / 69 89 / 89Dimensions Height mm 300 300 300 300 450 450

Width mm 1400 1400 1400 1400 1400 1400Depth mm 700 700 700 700 900 900

Weight kg 45 45 45 45 89 94Sound Pressure High / Low dBA 40 / 33 40 / 33 40 / 33 40 / 33 45 / 45 47 / 47Sound Power dBA 66 66 66 66 81 82

Outdoor Units RZQG125L8V1 RZQG125L8Y1 RZQSG125L8V1 RZQSG125L8Y1 RZQ200C RZQ250CDimensions Height x Width x Depth mm 1430 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 990 x 940 x 320 1680 x 930 x 765 1680 x 930 x 765Weight kg 102 101 81 82 183 184Electrical Details Power Supply 1ph - see notes 3ph - see notes 1ph - see notes 3ph - see notes 3ph - see notes

Running Current A 14.80 4.89 17.30 5.72 4.61 6.35Starting Current A 4 4 4 4 4 4Max Fuse Size A 32 20 32 20 25 25

Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 7/8 1/2 / 7/8Pipework Maximum Length m 75 75 50 50 100 100

Maximum Vertical Rise m 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30Additional Charge g/m Refer to Installation Manual Refer to Installation ManualHolding Charge kg 4.0 4.0 2.9 2.9 8.3 9.3

Sound Pressure High dBA 51 51 54 54 57 57Sound Power dBA 67 67 70 70 78 78

Trade Fan Coil Price £1,244.00 £1,244.00 £1,244.00 £1,244.00 £1,561.00 £1,912.00Trade Condensing Unit Price £1,666.00 £1,743.00 £1,338.00 £1,378.00 £2,576.00 £2,698.00Total System Price £2,910.00 £2,987.00 £2,582.00 £2,622.00 £4,137.00 £4,610.00

Features:• High static units for longer ducted runs• Up to 200Pa External Static Pressure • Auto balancing air flow / ESP on commissioning• Comms, computer and server room cooling possible (Seasonal Smart only)• Super inverter technology: reduces power consumption by up to 70% compared to non inverter units• Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart only)

Accessory Ref Description Trade PriceBRC4C65 Wireless remote controller £152.00 EKRORO3 Remote on/off control interface kit £29.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £92.00 RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock £235.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00KRCS01-4 Remote room mounted temperature sensor £47.00 KLIC-DI KNX Interface for Sky Air and VRV systems £185.00 DTA112B51 Adaptor PCB for interface to Daikin centralised control systems £89.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories:

Cooling HeatingRZQG -15°C -20°CRZQSG -15°C -15°CRZQ -5°C -15°C

Notes:

Page 36: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial34

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Multi Series Inverters offer the ability to connect up to 5 fan coils to one outdoor unit. With the MXS range it is possible to install indoor units throughout a house or small commercial premises and only use 1 outdoor unit. Each indoor unit will have it’s own controller and will be able to operate in heating or cooling.

Multi Series

Heating & coolingConnectable Indoor Units

Wall mounted Floor standing Flexi type Round flow cassette

Fully flat cassette

Concealed ceiling Ceiling suspended

FTXG-L CTXS-K FTXS-K FTXS-G FTX-JV FVXG-K FVXS-F FLXS-B(9) FCQG-F FFQ-C FDXS-F(9) FDBQ-B/FBQ-C8 FHQ-C

20 25 35 50 15 35 20 25 35 42 50 60 71 20 25 35 25 35 50 25 35 50 25 35 50 60 35 50 60 25 35 50 60 25 35 50 60 25 35 50 60 35 50 60

2MXS40H ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

2MXS50H ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

3MXS40K ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

3MXS52E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

3MXS68G ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4MXS68F ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4MXS80E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

5MXS90E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Outdoor Unit Indoor Unit Cooling Mode Heating Mode

SEER Energy efficiency

class

Annual energy consumption

kWh/a

Design load PDesign kW

SCOP Energy efficiency

class

Annual electricity

consumption kWh/a

Design load PDesign at -10°C kW

Declared heating capacity at -10°C

Back up heating capacity

2MXS40H3V1B 2 x FTXS20K2V1B 6.61 A++ 212 4.0 4.12 A+ 1029 3.1 2.5 0.62MXS50H3V1B 2 x FTXS25K2V1B 6.61 A++ 265 5.0 4.00 A+ 1466 4.2 3.4 0.83MXS40K3V1B 2 x FTXS20K2V1B 6.9 A++ 203 4.0 4.05 A+ 1641 4.8 3.9 0.93MXS52E4V1B 2 x CTXS15K2V1B,

1 x FTXS20K2V1B7.15 A++ 245 5.0 4.31 A+ 1605 5.0 4.0 1.0

3MXS68G3V1B 1 x CTXS15K2V1B, 2 x FTXS20K2V1B

5.34 A 446 6.8 4.00 A+ 1868 5.4 4.4 1.0

4MXS68F3V1B 2 x CTXS15K2V1B, 2 x FTXS20K2V1B

5.68 A+ 420 6.8 4.15 A+ 1953 5.8 4.7 1.1

4MXS80E3V3B 3 x CTXS15K2V1B, 1 x FTXS35K2V1B

6.16 A++ 416 7.4 4.00 A+ 2194 6.3 5.1 1.2

5MXS90E3V3B 2 x CTXS15K2V1B, 3 x FTXS20K2V1B

6.42 A++ 424 7.8 4.19 A+ 2161 6.5 5.3 1.2

For seasonal data in combination with other indoor units, please consult www.daikineurope.com/energylabel

Emura Wall Mounted Fan Coil Units FTXG20LW FTXG25LW FTXG35LW FTXG50LW FTXG20LS FTXG25LS FTXG35LS FTXG50LSTrade Fan Coil Unit Price £262.00 £276.00 £310.00 £473.00 £313.00 £329.00 £369.00 £565.00

Wall Mounted Fan Coil Units CTXS15K FTXS20K FTXS25K FTXS35K FTXS42K FTXS50K FTXS60G FTXS71GTrade Fan Coil Unit Price £146.00 £154.00 £165.00 £189.00 £212.00 £294.00 £300.00 £400.00

Wall Mounted Low Inverter Fan Coil Units FTX20JV FTX25JV FTX35JVTrade Fan Coil Unit Price £123.00 £136.00 £154.00

Flexi Fan Coil Units FLXS25B FLXS35B9 FLXS50BTrade Fan Coil Unit Price £376.00 £423.00 £459.00

Nexura Floor Standing Fan Coil Units FVXG25K FVXG35K FVXG50KTrade Fan Coil Unit Price £631.00 £679.00 £744.00

Floor Standing Fan Coil Units FVXS25F FVXS35F FVXS50FTrade Fan Coil Unit Price £523.00 £564.00 £616.00

Compact Roundflow Cassette Fan Coil Units FCQG35F FCQG50F FCQG60FTrade Fan Coil Unit Price £718.00 £735.00 £782.00

600 Sq 600 Sq 4-way blow Cassette Fan Coil Units FFQ25C FFQ35C FFQ50C FFQ60CTrade Fan Coil Unit Price £663.00 £727.00 £802.00 £849.00

Ceiling Suspended Fan Coil Units FHQ35C FHQ50C FHQ60CTrade Fan Coil Unit Price £710.00 £770.00 £845.00

Ducted Fan Coil Units FDBQ25B FBQ35C8 FBQ50C8 FBQ60C8Trade Fan Coil Unit Price £424.00 £547.00 £575.00 £639.00

Slim Ducted Fan Coil Units FDXS25F FDXS35F FDXS50F9 FDXS60FTrade Fan Coil Unit Price £394.00 £441.00 £477.00 £524.00

Multi Split & Mini VRV Fan Coils

Notes: i) Accessories for fan coils - refer to pair

system pages

ii) All fan coil units standard with auto restart after power failure

iii) All fan coil units supplied as standard with remote controller

iv) FDXS fan coil units supplied as standard with air filter

v) 2MXS40-50H can only be used with FTXG, FTXS, FTX, FDXS, FVXG, FVXS, FLXS fan coil units

Page 37: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 35

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Multi Series InvertersMXS-E/F/G/H/K

Outdoor Units 2MXS40H 2MXS50H 3MXS40K 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90ECapacity Nominal Cooling kW 4.00 5.00 4.00 5.20 6.80 6.80 8.00 9.00

Nominal Heating kW 4.40 5.70 4.60 6.80 8.60 8.60 9.60 10.40Dimensions Height mm 550 550 735 735 735 735 770 770

Width mm 765 765 936 936 936 936 900 900Depth mm 285 285 300 300 300 300 320 320

Weight kg 38 42 49 49 58 58 72 73Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps Refer to Multi Combination TablesStarting Current amps 4 4 4 4 4 4 4 4Fuse Rating amps 16 16 16 20 20 20 20 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 1.2 1.6 2.0 2.0 2.6 2.6 3.0 3.0

Sound Pressure High dBA 47 48 46 46 48 48 48 52Sound Power 62 63 59 59 61 61 62 66Piping Limits Maximum Length m 30 30 50 50 60 60 70 75

Maximum Vertical Rise m 15 15 15 15 15 15 15 15Piping Connections Liquid inches 2x 1/4 2x 1/4 3x 1/4 3x 1/4 3x 1/4 4x 1/4 4x 1/4 5x 1/4

Gas inches 2x 3/8 3/8 1/2 2x3/8 1/2 2x3/8 1/2 3/8 2x1/2 2x3/8 2x1/2 3/8 1/2 2x5/8 2x3/8 1/2 2x5/8Number of Connected Indoor Units 2 2 3 3 3 4 4 5

Trade Condensing Unit Price £998.00 £1,104.00 £1,040.00 £1,156.00 £1,637.00 £1,766.00 £1,989.00 £2,141.00

Notes:i) Minimum ambient operating temperatures:

Cooling Heating2MXS40, 50 10°C -15°C3MXS40, 52, 68 -10°C -15°C4MXS68, 80 -10°C -15°C5MXS90 -10°C -15°C

Accessory Ref Description Trade PriceUK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.CGM Condensing Unit Guard size 42-71 £296.00

Accessories:

Mini VRV for Residential ApplicationsRXYSQ-P8

Outdoor Units RXYSQ4P8V1 RXYSQ5P8V1 RXYSQ6P8V1Capacity Nominal Cooling kW 12.60 14.00 15.50

Nominal Heating kW 14.20 16.00 18.00Dimensions Height mm 1345 1345 1345

Width mm 900 900 900Depth mm 320 320 320

Weight kg 120 120 120Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps Refer to Multi Combination TablesStarting Current amps 4 4 4Fuse Rating amps 32 32 32

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 4.0 4.0 4.0

Sound Pressure High dBA 50 51 53Sound Power High dBA 66 67 69Piping Limits Maximum Length m 115 135 145

Maximum Vertical Rise m data book data book data bookPiping Connections Liquid inches 3/8 3/8 3/8

Gas inches 5/8 5/8 3/4Capacity Index Limit 50~130 62.5~162.5 70~182Number of Connected Indoor Units 8 10 13

Trade Condensing Unit Price £2,735.00 £3,074.00 £3,431.00

Notes:i) Minimum ambient operating temperatures:

Cooling HeatingRXYSQ-P8 -5°C -20°C

Please note: RXYSQ units are subject to VRV discount level

Accessory Ref Description Trade PriceBPMKS967A2 Branch Provider Kit - 2 fan coil units £356.00 BPMKS967A3 Branch Provider Kit - 3 fan coil units £380.00 KHRQ22M20T R410a 2 Pipe Refnet Joint £29.00

Accessories:

Page 38: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial36

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Wall Mounted Fan Coil Units FAQ71C FAQ100CTrade Fan Coil Unit Price £799.00 £863.00

Ceiling Suspended Fan Coil Units FHQ35C FHQ50C FHQ60C FHQ71C FHQ100C FHQ125CTrade Fan Coil Unit Price £710.00 £770.00 £845.00 £989.00 £1,051.00 £1,315.00

Compact Roundflow Cassette Fan Coil Units FCQG35F FCQG50F FCQG60F FCQG71F FCQG100F FCQG125FTrade Fan Coil Unit Price £718.00 £735.00 £782.00 £829.00 £940.00 £1,028.00

High COP Roundflow Cassette Fan Coil Units FCQHG71F FCQHG100F FCQHG125FTrade Fan Coil Unit Price £829.00 £940.00 £1,028.00

600 Sq 4-way Blow Cassette Fan Coil Units FFQ35C FFQ50C FFQ60CTrade Fan Coil Unit Price £727.00 £802.00 £849.00

Under Ceiling 4-way Blow Cassette Fan Coil Units FUQ71C FUQ100C FUQ125CTrade Fan Coil Unit Price £915.00 £1,004.00 £1,109.00

DC Ducted Fan Coil Units FBQ35C8 FBQ50C8 FBQ60C8 FBQ71C8 FBQ100C8 FBQ125C8Trade Fan Coil Unit Price £547.00 £575.00 £639.00 £918.00 £960.00 £1,137.00

Slim Ducted Fan Coil Units FDXS25F FDXS35F FDXS50F9 FDXS60FTrade Fan Coil Unit Price £394.00 £441.00 £477.00 £524.00

High Static Ducted Fan Coil Units FDQ125CTrade Fan Coil Unit Price £1,244.00

Twin, Triple and Double Twin Outdoor UnitsPossible Combinations

Outdoor Units Nominal Cooling kW Nominal Heating kW Possible Combinations Model TypesRZQG71L8V1 / Y1 6.80 7.50 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQSG71L3V1 / Y1 6.80 7.50 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQG100L8V1 / Y1 9.50 10.80 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQG100L8V1 / Y1 9.50 10.80 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQSG100L8V1 / Y1 9.50 10.80 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQSG100L8V1 / Y1 9.50 10.80 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQG125L8V1 / Y1 12.00 13.50 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQRZQG125L8V1 / Y1 12.00 13.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQG125L8V1 / Y1 12.00 13.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQSG125L8V1 / Y1 12.00 13.50 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQRZQSG125L8V1 / Y1 12.00 13.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQSG125L8V1 / Y1 12.00 13.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQG140L7V1 / LY1 13.40 15.50 71 + 71 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQRZQG140L7V1 / LY1 13.40 15.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQG140L7V1 / LY1 13.40 15.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQSG140LV1 / LY1 13.40 15.50 71 + 71 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQRZQSG140LV1 / LY1 13.40 15.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQSG140LV1 / LY1 13.40 15.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQ200 19.50 23.40 100 + 100 FCQG, FCQHG, FBQ, FHQG, FUQ, FAQRZQ200 19.50 23.40 60 + 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQRZQ200 19.50 23.40 71 + 71 + 71 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQRZQ200 19.50 23.40 50 + 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQ250 25.00 27.00 125 + 125 FCQG, FCQHG, FBQ, FHQ, FUQ, FDQRZQ250 25.00 27.00 60 + 60 + 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQ

Notes:These systems allow a mixture of fan coil types and sizes on the same condensing unit. Each system is operated on the Master and Slave principle from one remote controller.

As the number of possible combinations is so great, we are unable to show each system as separate prices within the price list.

To calculate a system price please refer to the next pages for individual fan coil and condensing unit prices and remember to add the pipework joints listed as accessory items on the following pages.

Each fan coil unit includes within its price for a remote controller. As a complete system requires only one controller, you will need to subtract the controller cost from all but one fan coil on each system.

EXAMPLE: TRADE EACH TRADE TOTALHeat pump triple system using the following: 3 No FCQG71-F Fan coil units £829.00 £2,487.001 No RZQ200C Condensing unit £2,578.00 £2,578.001 No KHRQ250H7 Pipework branch kit £81.00 £81.002 No BRC1E52A Remote controller (Credit) -£76.00 -£152.00 TOTAL £4,994.00

Twin, Triple and Double Twin Outdoor UnitsFan Coils

Notes:i) Each of the fan coil units includes one remote controller BRC1E52A

ii) FBQ50C to 71C fan coil units require a separate 1 ph power supply when connected to RZQ200 and 250C

iii) Self cleaning deco-panel BYCQ140DG is compatible on cassettes used in twin, triple and double twin applications

iv) For seasonal data on Twin, Triple and Double Twin applications please consult www.daikineurope.com/energylabel

v) Accessories for fan coils and condensing units - refer to pair system pages

Page 39: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 37

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Seasonal Smart InverterRZQG

Outdoor Units Seasonal Smart Inverter Seasonal Smart Inverter Super InverterSingle Phase 3 Phase

RZQG 71L8V1

RZQG 100L8V1

RZQG 125L8V1

RZQG 140L7V1

RZQG-71L8Y1

RZQG-100L8Y1

RZQG-125L8Y1

RZQG-140LY1

RZQ200C RZQ250C

Dimensions Height mm 990 1430 1430 1430 990 1430 1430 1430 1680 1680Width mm 940 940 940 940 940 940 940 940 930 930Depth mm 320 320 320 320 320 320 320 320 765 765

Weight kg 78 102 102 102 80 101 101 101 183 184Electrical Details Power Supply 1ph 3ph 3ph

Running Current A data book data book data bookStarting Current A 4 4 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20 25 25

Interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 7/8 1/2 / 7/8Pipework Maximum Length m 50 75 75 75 50 75 75 75 100 100

Maximum Vertical Rise m 30Precharged to m 30Additional Charge g/m Refer to Installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0 8.3 9.3

Sound Pressure High dBA 48 50 51 52 48 50 51 52 57 57Sound Power 64 66 67 69 64 66 67 69 78 78

Trade Condensing Unit Price £1,191.00 £1,514.00 £1,666.00 £1,901.00 £1,227.00 £1,584.00 £1,743.00 £2,002.00 £2,576.00 £2,698.00

Accessory Ref Description Trade PriceKHRQ22M20T R410a 2 Pipe Refnet Joint £29.00 KHRQ127H Triple Refnet Joint - RZQS71~140,RZQ100~140 £65.00 KHRQ250H7 Triple Refnet Joint - RZQ200~250 £81.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Accessories: Notes:i) Accessories for fan coils and condensing

units - refer to pair system pages

Seasonal Classic InverterRZQSG

Outdoor Units Seasonal Classic Inverter Seasonal Classic InverterSingle Phase 3 Phase

RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1Dimensions Height mm 770 990 990 1430 990 990 1430

Width mm 900 940 940 940 940 940 940Depth mm 320 320 320 320 320 320 320

Weight kg 67 81 81 102 82 82 101Electrical Details Power Supply 1ph 3ph

Running Current A data book data bookStarting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

Interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum Length m 50 50 50 50 50 50 50

Maximum Vertical Rise m 30Precharged to m 30Additional Charge g/m Refer to Installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power 65 69 70 69 69 70 69

Trade Condensing Unit Price £881.00 £1,220.00 £1,338.00 £1,490.00 £1,257.00 £1,378.00 £1,535.00

Accessories:Accessory Ref Description Trade PriceKHRQ22M20T R410a 2 Pipe Refnet Joint £29.00 KHRQ127H Triple Refnet Joint - RZQS71~140,RZQ100~140 £65.00 KHRQ250H7 Triple Refnet Joint - RZQ200~250 £81.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £37.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £46.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £56.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £59.00 UK.CGM Condensing Unit Guard size 42-71 £296.00 UK.CGL Condensing Unit Guard size 100-140 including RXYSQ £354.00

Notes:i) Accessories for fan coils and condensing

units - refer to pair system pages

Page 40: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial38

SPLI

T, S

KY

AIR

HEA

T PU

MPS

ENERGY

SAVINGS UP TO

72%

AIR

SEPARATION

EFFICIENCY

UP TO

85%PAYBACK TIME

LESS THAN

1.5YEARS

Air curtains for light commercial applicationsBiddle Standard air curtains are the ideal solution for retailers and consultants to combat the issue of climate separation across their outlet or office doorway.

Using a combination of rectifier technology, optimised air velocity and temperature control they deliver greater comfort to staff and customers alike, all year round, in all weathers.

In conjunction with Biddle, Daikin now offer the best air curtain to the market, coupling the benefits of the Biddle air curtain technology with the benefits of the Daikin heat pump inverter technology.

Biddle Standard air curtains are connected to selected Daikin ERQ heat pump inverter condensing units offering:

• Wide capacity range for maximum application potential plus flexible control options

• R-410A refrigerant, single and 3 phase

• Wide operation range: -5~46°C in cooling and -20~15.5°C in heating

Air Curtains

Small Air Curtains: Free Hanging, Cassette and Recessed

F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet

Accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £76.00 KRCS01-1 Remote room mounted temperature sensor £46.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00

Matching Air Cooled Condensing Units

Single Phase Three PhaseERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1

Trade Unit Price £1,533.00 £1,709.00 £2,049.00 £1,743.00 £3,271.00 £3,408.00CYQS150DK80*BN •CYQS200DK100*BN • •CYQS250DK140*BN • • • •

Accessories: Notes:i) Please refer to page 40 for ERQ features

and specifications

ii) To calculate the price for a complete system, add together the prices of the Air Curtain, ERQ condensing unit and remote controller as below example:

1 No CYQS150DK80FBN £3,635.00

1 No ERQ100AV1 £1,533.00 1 No BRC1E52A £76.00

TOTAL £5,244.00

BIDDLE STANDARD AIR CURTAIN - SMALL CYQS150DK80*BN CYQS200DK100*BN CYQS250DK140*BN* = F * = C * = R * = F * = C * = R * = F * = C * = R

Heating Capacity speed 3 kW 9.00 11.60 16.20Delta T Inlet = room temperature speed 3 k 15 15 16Power Input (50Hz) Fan only / Heating kW 0.35 / 0.35 0.46 / 0.46 0.58 / 0.58Maximum Door Width m 1.50 2.00 2.50Mounting Height *2 Max / Min m 2.3/2.0 2.3/2.0 2.3/2.0Dimensions Height mm 270 270 270 270 270 270 270 270 270

Width mm 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 590 821 561 590 821 561 590 821 561

Weight kg 66 83 88 83 102 108 107 129 137Casing Colour white RAL9010 white RAL9010 white RAL9010Minimum requiring ceiling void mm 420 420 420Fan - Air Flow Rate Heating speed 3 m3/sec 0.485 0.647 0.808Sound Pressure Heating speed 3 dBA 49 50 51Refrigerant Type R-410A R-410A R-410APiping Connections Liquid (OD) / Gas mm 9.52/16.0 9.52/16.0 9.52/19.0Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50

Trade Unit Price £3,635.00 £3,635.00 £3,831.00 £4,422.00 £4,422.00 £4,795.00 £4,964.00 £4,964.00 £5,373.00

Page 41: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 39

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Medium Air Curtains: Free Hanging, Cassette and Recessed

F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet

Accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £76.00 KRCS01-1 Remote room mounted temperature sensor £46.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV £251.00

Single Phase Three PhaseERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1

Trade Unit Price £1,533.00 £1,709.00 £2,049.00 £1,743.00 £3,271.00 £3,408.00CYQM100DK80*BN •CYQM150DK80*BN • •CYQM200DK100*BN • • •CYQM250DK140*BN • •

Accessories: Notes:i) Please refer to page 40 for ERQ features

and specifications

ii) To calculate the price for a complete system, add together the prices of the Air Curtain, ERQ condensing unit and remote controller as below example:

1 No CYQM150DK80FBN £4,199.00

1 No ERQ125AV1 £1,709.00 1 No BRC1E52A £76.00

TOTAL £5,984.00

BIDDLE STANDARD AIR CURTAIN - MEDIUM CYQM100DK80*BN CYQM150DK80*BN CYQM200DK100*BN CYQM250DK140*BN* = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = R

Heating Capacity speed 3 kW 9.20 11.00 13.40 19.90Delta T Inlet = room temperature speed 3 k 17 14 13 15Power Input (50Hz) Fan only / Heating kW 0.37 / 0.37 0.56 / 0.56 0.75 / 0.75 0.94 / 0.94Maximum Door Width m 1.00 1.50 2.00 2.50Mounting Height *2 Max / Min m 2.5/2.3 2.5/2.3 2.5/2.3 2.5/2.3Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 590 821 561 590 821 561 590 821 561 590 821 561

Weight kg 57 68 66 73 88 93 94 111 117 108 136 144Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010Minimum requiring ceiling void mm 420 420 420 420Fan - Air Flow Rate Heating speed 3 m3/sec 0.446 0.669 0.892 1.115Sound Pressure Heating speed 3 dBA 50 51 53 54Refrigerant Type R-410A R-410A R-410A R-410APiping Connections Liquid (OD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

Trade Unit Price £3,524.00 £3,524.00 £3,637.00 £4,199.00 £4,199.00 £4,393.00 £5,258.00 £5,258.00 £5,630.00 £6,020.00 £6,020.00 £6,421.00

Large Air Curtains: Free Hanging, Cassette and Recessed

F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet

Accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £76.00 KRCS01-1 Remote room mounted temperature sensor £46.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV. £251.00

Single Phase Three PhaseERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1

Trade Unit Price £1,533.00 £1,709.00 £2,049.00 £1,743.00 £3,271.00 £3,408.00CYQL100DK125*BN • • • •CYQL150DK200*BN • •CYQL200DK250*BN •CYQL250DK250*BN •

Accessories: Notes:i) Please refer to page 40 for ERQ features

and specifications

ii) To calculate the price for a complete system, add together the prices of the Air Curtain, ERQ condensing unit and remote controller as below example:

1 No CYQL100DK125FBN £4,021.00

1 No ERQ125AV1 £1,709.00 1 No BRC1E52A £76.00

TOTAL £5,806.00

BIDDLE STANDARD AIR CURTAIN - LARGE CYQL100DK125*BN CYQL150DK200*BN CYQL200DK250*BN CYQL250DK250*BN* = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = R

Heating Capacity speed 3 kW 15.60 23.30 29.40 31.10Delta T Inlet = room temperature speed 3 k 15 15 14 12Power Input (50Hz) Fan only / Heating kW 0.75 / 0.75 1.13 / 1.13 1.50 / 1.50 1.88 / 1.88Maximum Door Width m 1.00 1.50 2.00 2.50Mounting Height *2 Max / Min m 3.0/2.5 3.0/2.5 3.0/2.5 3.0/2.5Dimensions Height mm 370 370 370 370 370 370 370 370 370 370 370 370

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 774 1105 745 774 1105 745 774 1105 745 774 1105 745

Weight kg 76 81 83 100 118 141 126 151 155 157 190 196Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010Minimum requiring ceiling void mm 520 520 520 520Fan - Air Flow Rate Heating speed 3 m3/sec 0.861 1.292 1.722 2.153Sound Pressure Heating speed 3 dBA 53 54 56 57Refrigerant Type R-410A R-410A R-410A R-410APiping Connections Liquid (OD) / Gas mm 9.52/16.0 9.52/19.0 9.52/22.0 9.52/22.0Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

Trade Unit Price £4,021.00 £4,021.00 £4,032.00 £5,736.00 £5,736.00 £5,921.00 £7,121.00 £7,121.00 £7,491.00 £8,311.00 £8,311.00 £8,769.00

Page 42: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial40

SPLI

T, S

KY

AIR

HEA

T PU

MPS

For central ducted distribution systems Daikin has the solution for providing cooling and heating of the air, enabling optimal comfort and efficiency.

Even without the benefit of individual room control, the system can provide a flexible energy saving answer over traditional methods through the incorporation of inverter control and heat pump technology.

The following pages include Packaged Heat Pump Rooftop systems, with optional economisers, to heat pump condensing units and connection kits for use with other manufacturers heating and cooling coils.

Central Ducted Solutions

Outdoor unit Trade Unit Price Control box Expansion Valve Kitcontrol z control y control xl class 63 class 80 class 100 class 125 class 140 class 200 class 250EKEQDCB EKEQFCB EKEQDCB/RTD EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250

Coil Volume dm3 min 1.66 2.09 2.65 3.31 4.13 4.63 6.61 max 2.08 2.64 3.30 4.12 4.62 6.60 8.25

1ph ERQ100AV1 £1,503.00 P P P P P P P - - -ERQ125AV1 £1,675.00 P P P P P P P P - -ERQ140AV1 £2,009.00 P P P - P P P P - -

3ph ERQ125AW1 £1,709.00 P P P P P P P P - -ERQ200AW1 £3,207.00 P P P - - P P P P PERQ250AW1 £3,341.00 P P P - - - P P P P

Trade Acc. Price £342.00 £365.00 £568.00 £97.00 £104.00 £78.00 £90.00 £101.00 £120.00 £132.00

Air Cooled Heat Pump InverterCondensing Unit Kit for DX Coil

P: Pair Combination depending on air handling units coils volume X: Possibility to connect Control xl includes RTD-20

A new range of R410a inverter condensing units for pair application with air handling units:• Inverter controlled heat pump units

• Large capacity range (from 63 to 250 class)

• Ventilation and air conditioning in 1 solution

• EKEXV-kit & control boxes are designed for outdoor installation and can be wall mounted

• Per EKEXV-kit/control box, only 1 air handling unit coil can be connected

• Outdoor unit operation range: -5°CDB ~ 43°CDB

Flexible control possibilities:Control xl:Full external control from 3rd party temperature controller with volt free remote enable contact and linear variable capacity control output

Control y:External control from 3rd party temperature controller with volt free remote enable contact. Fixed evaporating temperature selection, range: +3°C to +10°C

Control z (BRC1D52 required):Control via Daikin BRC1D52 remote controller and return air or remote sensor (KRCS01-1 optional). A volt free remote enable contact is required to confirm fan operation status. For re-circ applications only

Liquid pipe

Gas pipe

Liquid pipe

Gas pipe

EV kit

Air handling unit

Field supply

Control boxF1,F2 communication

DDC control (control x)

Page 43: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 41

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Rooftop Packaged Unit – Heat Pump UATYQ

Notes:i) Minimum Ambient operating conditions ii) Supplied with remote controller as standard

iii) Economiser option is supplied as a kit for site assembly

iv) Low ambient kit for models UATYPC available on request

v) Please check stock & delivery period for all model sizes

vi) Standard delivery for all units does not include off-loading to kerbside

vii) UATYQ250/350 can be off-loaded by fork-lift if there is one on site

viii) All other units require crane or HIAB. Prices for HIAB available on request

Cooling HeatingUATYQ250~700 0°C -15°CUATYPC10~12 20°C -15°C

UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1 UATYPC10AY1 UATYPC12AY1Capacity Nominal Cooling kW 27.34 35.58 44.72 55.69 66.82 72.60 101.10 109.60

Nominal Heating kW 24.91 34.79 41.79 53.93 61.69 69.61 102.30 126.30Dimensions Height mm 1150 1028 1130 1048 1302 1302 1974 1974

Width mm 1638 2209 2209 2209 2209 2209 2252 2252Depth mm 2063 2113 2113 2670 2670 2670 3180 3180

Weight kg 490 660 690 780 830 970 1510 1600Air Flow Rate Indoor m3/min 93 122 160 190 205 233 312 354External Static Indoor Pa 147 147 147 206 206 206Air Flow Rate Outdoor m3/min 0 0 0 0 0 0 0 0Refrigerant R410a R407CSound Power Level Outdoor dBA 82 83 83 87 90 90 80 80Drain size mm 25.4 (OD)Electrical Details Power Supply V 400

Hz 50Phase 3ph

Running Current A 20.5 26.4 33.1 39.4 41.6 46.5 74.2 82.9Starting Current A 118 93 123 137 144 148 175 , 215 215x2Max Fuse Size A 32 40 40 50 50 50 125 125

Trade Unit Price £5,027.00 £5,234.00 £8,612.00 £9,476.00 £10,190.00 £10,904.00 £14,559.00 £15,816.00

Economiser ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1Trade Unit Price £886.00 £931.00 £976.00 £1,024.00 £1,076.00 £1,129.00

Page 44: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

SPLI

T, S

KY

AIR

HEA

T PU

MPS

Page 45: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

VRV

VRVThe VRV Total Solution 44

Heat Pump VRV IV 44

Price List 2014 43

Page 46: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial44

VRV

The VRV total solutionAir conditioning, refrigeration and cooling IT servers can generate masses of waste heat that can be reused to heat and ventilate other areas of the building or to provide hot water for wash rooms, at a much reduced cost.

By understanding the whole building’s heating and cooling needs at the outset, an integrated climate control solution can be delivered that offers much higher energy efficiency levels, thus reducing the carbon impact of a building. This means that all internal and external conditions must be taken into account in the design of the climate control system.

The VRV Total Solution

Many buildings today typically operate quite separate systems for heating, cooling, refrigeration and hot water. As a result, a huge amount of energy is wasted. To provide a much more efficient alternative, VRV technology has been developed into a total solution for heating, cooling, refrigeration and ventilation.

Heat Pump VRV IVRYYQ-TReplaces RXYQ-P9 / RXYHQ-P9 / RXYRQ-P9 / RXHQ-P

3 revolutionary features:

Variable refrigerant temperature Customise your VRV for best Seasonal Efficiency and comfort:

• Revolutionary variable refrigerant temperature control automatically adapts the system to individual building and climate requirements for greater efficiency and comfort

• Continuously adjusts refrigerant temperature to the actual temperature and capacity required

• Default mode optimised by Daikin for UK conditions with maximum efficiency and comfort

• Delivers annual cost savings of up to 28%

Continuous heating during defrost The new standard in heating comfort:

• Unique continuous heating technology makes VRV IV Heat Pump the best alternative to traditional heating systems

• Delivers uninterrupted heat, even during the defrost cycle

• Maintains comfortable indoor climate at all times

VRV configuratorAdvanced software for simplified commissioning, servicing, configuration and customisation:

• Simplified commissioning: graphical interface to configure, commission and upload system settings

• Simplified servicing: additional 7-segment indicator for easy and quick access to basic functions and error read out

• Manage systems over multiple sites

Page 47: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

VEN

TILA

TIO

N

VentilationVAM / VKM 46

Price List 2014 45

Page 48: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial46

VEN

TILA

TIO

N

With the advent of new building regulations, greater awareness of increasing energy costs and a responsibility towards environmental issues, modern commercial spaces are insulated better than ever.

Ventilation

Double glazing, thicker insulation and draught exclusion of course, help considerably towards reducing heating/cooling demand and burdens on the environment.

The down-side however, is that these same commercial spaces have now become, in effect, sealed boxes with little or no replenishment of the air.

Notes:i) Please contact your local sales office

for required options when combined operation with an air conditioning system is required

ii) Optional silencers, high efficiency filters etc are available. Prices and details on request

iii) VKM models must be connected as the slave indoor unit of a standard VRV indoor unit and share the same BRC1D52 remote controller and BSVQ unit ( If connected to Heat Recovery)

iv) UK.VH-CK VAM EHBX24 conversion kit cable included

Total Heat ExchangerVAM / VKM

VAM150FA VAM250FA VAM350FB VAM500FB VAM650FB VAM800FB VAM1000FB VAM1500FB VAM2000FB VKM50G VKM80G VKM100GDimensions Height mm 285 301 364 726 387

Width mm 776 828 1004 1514 1764Depth mm 525 816 868 1156 868 1156 832 1214

Weight kg 24 33 52 64 131 152 96 109 114Duct Connections mm 100Ø 150Ø 150Ø 200Ø 200Ø 250Ø 250Ø 350Ø 350Ø 200Ø 250Ø 250ØAir Flow Rate Ultra-High m3/hr 150 250 350 500 650 800 1000 1500 2000 500 750 950

High m3/hr 150 250 350 500 650 800 1000 1500 2000 500 750 950Low m3/hr 110 155 230 350 500 670 870 1200 1400 440 640 820

External Static Pressure

Ultra-High Pa 69 64 98 98 93 137 157 137 137 180 170 150High Pa 39 39 - - - - - - - 150 120 100Low Pa 20 20 - - - - - - - 110 80 70

Sound Pressure Level (Heat Exchange Mode)

Ultra-High dBA 28.5 29.0 32.0 33.0 34.5 36.0 36.0 39.5 40.0 39.0 41.5 41.0High dBA 27.5 27.0 31.5 31.5 33.0 34.5 35.0 38.0 38.0 37.0 39.0 39.0Low dBA 21.5 22.0 23.5 24.5 27.0 31.0 31.0 34.0 35.0 35.5 37.0 36.5

Electrical Details Power Supply V 230Hz 50Phase 1

Running Current A 0.9 0.9 0.9 1.3 1.6 2.5 3.0 5.0 5.0 3.8 3.8 3.8Max Fuse Size A 15 15 15 15 15 15 15 15 15 15 15 15

Trade Unit Price £430.00 £514.00 £681.00 £872.00 £1,067.00 £1,257.00 £1,441.00 £2,201.00 £2,871.00 £2,089.00 £2,536.00 £3,016.00

Optional Accessory Compatibility VAM150FA VAM250FA VAM350FB VAM500FB VAM650FB VAM800FB VAM1000FB VAM1500FB VAM2000FB VKM50G VKM80G VKM100GInlet Heater Battery+ VH1B VH2B VH3B VH4B or VH4/AB VH5B - - -Air Filter - - EKAFV50F* EKAFV80F* EKAFV100F* 2 x EKAFV100F* - - -

Optional Inlet Heater Battery VH1B VH2B VH3B VH4B VH4/AB VH5BCapacity kW 1.0 1.0 1.0 1.5 2.5 2.5Duct Diamater mm 100 150 200 250 300 350

Trade Unit Price £590.00 £596.00 £600.00 £650.00 £644.00 £650.00

+ Heater battery does NOT require PCB adaptor to connect to VAM* available in Medium M6, Fine F7 and Fine F8. Only one filter is required to cover the whole of one side of the heat exchanger, even if the heat exchanger has two sections.

Accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £76.00 KRP2A52/UK.FB2 System adaptor PCB for remote on/off, status indication and temperature setting £202.00 RTD-Net/UK.FB2 Modbus Interface PCB for Sky Air and VRV £190.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV. POA BRP4A50 PCB Adaptor for VAM-A series connection to 3rd party heater £94.00 KRP50-2 PCB Adaptor for VAM-A series connection to humidifier £107.00 BRP4A50A PCB Adaptor for VAM-B Series connection to 3rd party heater or humidifier £118.00 EKAFV50F6 Air filter for VAM350 / 500FB : Medium M6 £51.00 EKAFV50F7 Air filter for VAM350 / 500FB : Fine F7 £57.00 EKAFV50F8 Air filter for VAM350 / 500FB : Fine F8 £62.00 EKAFV80F6 Air filter for VAM650 / 800FB : Medium M6 £57.00 EKAFV80F7 Air filter for VAM650 / 800FB : Fine F8 £62.00 EKAFV80F8 Air filter for VAM650 / 800FB : Fine F7 £68.00 EKAFV100F6 Air filter for VAM1000 / 2000FB : Medium M6 £87.00 EKAFV100F7 Air filter for VAM1000 / 2000FB : Fine F7 £93.00 EKAFV100F8 Air filter for VAM1000 / 2000FB : Fine F8 £98.00

Accessories:

Daikin offers a variety of solutions for the provision of fresh air ventilation to offices, hotels, stores and other commercial outlets.

Heat Reclaim VentilationProper ventilation is a key component of climate control in buildings, offices and shops. In its basic function, it ensures a flow of incoming fresh air and outgoing stale air. Our HRV (heat reclaim ventilation) solution can do much more. It can recover heat and OPTIMISE THE BALANCE BETWEEN INDOOR AND OUTDOOR TEMPERATURE AND HUMIDITY, thus reducing the load on the system and increasing efficiency.

Page 49: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

APP

LIED

AppliedWater Chillers 48

Chilled Water Fan Coils 51

Price List 2014 47

Page 50: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial48

APP

LIED

Air Cooled Water Chillers

ModelNo

Nominal CoolingkW

NominalHeatingkW

PowerSupply

TradePrice

Air Cooled Inverter Packaged Swing / Scroll Compressor – R410a

EWAQ005ADVP 5.20 - 1-phase £2,061.00EWAQ006ADVP 6.00 - 1-phase £2,259.00EWAQ007ADVP 7.10 - 1-phase £2,503.00EWAQ009ACV3P 8.60 - 1-phase £2,856.00EWAQ010ACV3P 9.60 - 1-phase £3,023.00EWAQ011ACV3P 11.10 - 1-phase £3,249.00EWAQ009ACW1P 9.10 - 3-phase £2,980.00EWAQ011ACW1P 11.10 - 3-phase £3,276.00EWAQ013ACW1P 13.30 - 3-phase £3,471.00

Air Cooled Inverter Packaged Scroll Compressor – R410a

EWAQ016BAWN 17.4 - 3 - phase £4,714.00EWAQ021BAWN 21.7 - 3 - phase £5,550.00EWAQ025BAWN 25.8 - 3 - phase £6,260.00EWAQ032BAWN 32.3 - 3 - phase £7,223.00EWAQ040BAWN 43.4 - 3 - phase £9,552.00EWAQ050BAWN 51.8 - 3 - phase £10,643.00EWAQ064BAWN 64.5 - 3 - phase £12,290.00

Air cooled packaged scroll compressor – R407c

EUWAN5KBZW 11.30 - 3-phase £2,425.00EUWAN8KBZW 17.90 - 3-phase £3,598.00EUWAN10KBZW 22.50 - 3-phase £4,069.00EUWAN12KBZW 26.50 - 3-phase £4,278.00EUWAN16KBZW 34.60 - 3-phase £5,695.00EUWAN20KBZW 46.60 - 3-phase £7,200.00EUWAN24KBZW 55.30 - 3-phase £8,017.00

Cooling Capacity:

Notes:i) Please contact your local sales office for further information on

these products

ii) Nominal cooling capacities are based on 35°C ambient, chilled water @ 12/7°C

iii) EWAQ -A series only operates in cooling down to ambients of +10°C

iv) The EWAQ064BA delivery does not include offloading to kerbside. Additional costs for delivery with a Hi-ab are available on request

Air Cooled Packaged Scroll Compressor – R407c c/w hydraulic pump and expansion vessel

EUWAP5KBZW 11.30 - 3-phase £2,795.00EUWAP8KBZW 17.90 - 3-phase £4,060.00EUWAP10KBZW 22.50 - 3-phase £4,563.00EUWAP12KBZW 26.50 - 3-phase £4,777.00EUWAP16KBZW 34.60 - 3-phase £6,112.00EUWAP20KBZW 46.60 - 3-phase £7,691.00EUWAP24KBZW 55.30 - 3-phase £8,532.00

Air Cooled Packaged Scroll Compressor – R407c c/w hydraulic pump, expansion vessel and buffer tank

EUWAB5KBZW 11.30 - 3-phase £3,054.00EUWAB8KBZW 17.90 - 3-phase £4,378.00EUWAB10KBZW 22.50 - 3-phase £4,904.00EUWAB12KBZW 26.50 - 3-phase £5,126.00EUWAB16KBZW 34.60 - 3-phase £6,392.00EUWAB20KBZW 46.60 - 3-phase £8,018.00EUWAB24KBZW 55.30 - 3-phase £8,876.00

To Fit Model EWAQ-A EWAQ-ADVP EWAQ-ACV3P EWAQ-ACW1PPart No Description 005 006 007 009 010 011 009 011 013OP10 Evaporator Heater Tape £276 £276 £276 £304 £304 £304 £304 £304 £304

To Fit Model EWAQ-BAPart No Description 016 021 025 032 040 050 064UK57-BA Evaporator Heater Tape £394 £394 £394 £394 £496 £496 £496UK08B-BA Chilled Water Down to -10 £292 £292 £292 £292 £394 £394 £394UK78-BA Low Lift Pump £438 £438 £438 £584 £584 £584 £584UK79-BA High Lift Pump £642 £642 £642 £642 £875 £875 £875

To Fit Model EUWAN-KBZWPart No Description 5 8 10 12 16 20 24OP10 Evaporator Heater Tape £112 £112 £112 £112 £112 £112 £112OPHF High Static Fan £17 £40 £40 £40 £82 £82 £82OPZH Chilled Water Down to -5 £167 £167 £167 £167 £167 £167 £167OPZL Chilled Water Down to -10 £167 £167 £167 £167 £167 £167 £167

To Fit Model EUWAP-KBZWPart No Description 5 8 10 12 16 20 24OP10 Evaporator Heater Tape £225 £225 £225 £225 £225 £225 £225OPHP High Static Pump £69 £69 £69 £69 £262 £262 £262OPHF High Static Fan £17 £40 £40 £40 £82 £82 £82OPZH Chilled Water Down to -5 £167 £167 £167 £167 £167 £167 £167OPZL Chilled Water Down to -10 £167 £167 £167 £167 £167 £167 £167

To Fit Model EUWAB-KBZWPart No Description 5 8 10 12 16 20 24OP10 Evaporator Heater Tape £276 £276 £276 £276 £276 £276 £276OPHP High Static Pump £69 £69 £69 £69 £262 £262 £262OPHF High Static Fan £17 £40 £40 £40 £82 £82 £82OPZH Chilled Water Down to -5 £167 £167 £167 £167 £167 £167 £167OPZL Chilled Water Down to -10 £167 £167 £167 £167 £167 £167 £167

Fitted Options:

Page 51: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 49

APP

LIED

Air Cooled Heat Pump Water Chillers

Air Cooled Heat Pump Inverter Packaged Swing / Scroll Compressor – R410a

EWYQ005ADVP 5.20 5.65 1-phase £2,380.00EWYQ006ADVP 6.00 6.35 1-phase £2,571.00EWYQ007ADVP 7.10 7.75 1-phase £2,845.00EWYQ009ACV3P 8.60 9.90 1-phase £3,288.00EWYQ010ACV3P 9.60 11.40 1-phase £3,415.00EWYQ011ACV3P 11.10 12.90 1-phase £3,460.00EWYQ009ACW1P 9.10 10.90 3-phase £3,415.00EWYQ011ACW1P 11.10 12.40 3-phase £3,706.00EWYQ013ACW1P 13.30 13.90 3-phase £3,917.00

Air Cooled Heat Pump Inverter Packaged Scroll Compressor – R410a

EWYQ016BAWN 17.4 16.2 3-phase £5,421.00EWYQ021BAWN 21.7 20.3 3-phase £6,385.00EWYQ025BAWN 25.8 24.6 3-phase £7,202.00EWYQ032BAWN 32.3 30.7 3-phase £8,305.00EWYQ040BAWN 43.4 40.6 3-phase £10,985.00EWYQ050BAWN 51.8 49.0 3-phase £12,237.00EWYQ064BAWN 64.5 61.5 3-phase £14,135.00

Air Cooled Heat Pump Packaged Scroll Compressor – R407c

EUWYN5KBZW 9.10 11.90 3-phase £2,717.00EUWYN8KBZW 17.10 18.50 3-phase £4,181.00EUWYN10KBZW 21.00 24.00 3-phase £4,584.00EUWYN12KBZW 25.00 27.00 3-phase £4,860.00EUWYN16KBZW 34.20 37.00 3-phase £6,569.00EUWYN20KBZW 40.00 46.00 3-phase £7,966.00EUWYN24KBZW 50.00 54.00 3-phase £8,778.00

Cooling Capacity:ModelNo

Nominal CoolingkW

NominalHeatingkW

PowerSupply

TradePrice

Notes:i) Please contact your local sales office for further information on

these products

ii) Nominal cooling capacities are based on 35°C ambient, chilled water @ 12/7°C

iii) Nominal heating capacities are based on 7°C db / 6°C wb ambient, water @ 45 / 50°C

iv) EWYQ -A series only operates in cooling down to ambients of +10°C

v) The EWYQ064BA delivery does not include offloading to kerbside. Additional costs for delivery with a Hi-ab are available on request

Air Cooled Heat Pump Packaged Scroll Compressor – R407c c/w hydraulic pump and expansion vessel

EUWYP5KBZW 9.10 11.90 3-phase £3,094.00EUWYP8KBZW 17.10 18.50 3-phase £4,671.00EUWYP10KBZW 21.00 24.00 3-phase £5,089.00EUWYP12KBZW 25.00 27.00 3-phase £5,379.00EUWYP16KBZW 34.20 37.00 3-phase £7,005.00EUWYP20KBZW 40.00 46.00 3-phase £8,466.00EUWYP24KBZW 50.00 54.00 3-phase £9,291.00

Air Cooled Heat Pump Packaged Scroll Compressor – R407c c/w hydraulic pump, expansion vessel and buffer tank

EUWYB5KBZW 9.10 11.90 3-phase £3,354.00EUWYB8KBZW 17.10 18.50 3-phase £4,809.00EUWYB10KBZW 21.00 24.00 3-phase £5,382.00EUWYB12KBZW 25.00 27.00 3-phase £5,625.00EUWYB16KBZW 34.20 37.00 3-phase £7,021.00EUWYB20KBZW 40.00 46.00 3-phase £8,802.00EUWYB24KBZW 50.00 54.00 3-phase £9,748.00

To Fit Model EWYQ-A EWYQ-ADVP EWYQ-ACV3P EWYQ-ACW1PPart No Description 005 006 007 009 010 011 009 011 013OP10 Evaporator Heater Tape £276 £276 £276 £304 £304 £304 £304 £304 £304

To Fit Model EWYQ-BAPart No Description 016 021 025 032 040 050 064UK57-BA Evaporator Heater Tape £394 £394 £394 £394 £496 £496 £496UK08B-BA Chilled Water Down to -10 £292 £292 £292 £292 £394 £394 £394UK78-BA Low Lift Pump £438 £438 £438 £584 £584 £584 £584UK79-BA High Lift Pump £642 £642 £642 £642 £875 £875 £875

To Fit Model EUWYN-KBZWPart No Description 5 8 10 12 16 20 24OP10 Evaporator Heater Tape £112 £112 £112 £112 £112 £112 £112OPHF High Static Fan £17 £40 £40 £40 £82 £82 £82OPZH Chilled Water Down to -5 £167 £167 £167 £167 £167 £167 £167OPZL Chilled Water Down to -10 £167 £167 £167 £167 £167 £167 £167

To Fit Model EUWYP-KBZWPart No Description 5 8 10 12 16 20 24OP10 Evaporator Heater Tape £225 £225 £225 £225 £225 £225 £225OPHP High Static Pump £69 £69 £69 £69 £262 £262 £262OPHF High Static Fan £17 £40 £40 £40 £82 £82 £82OPZH Chilled Water Down to -5 £167 £167 £167 £167 £167 £167 £167OPZL Chilled Water Down to -10 £167 £167 £167 £167 £167 £167 £167

To Fit Model EUWYB-KBZWPart No Description 5 8 10 12 16 20 24OP10 Evaporator Heater Tape £276 £276 £276 £276 £276 £276 £276OPHP High Static Pump £69 £69 £69 £69 £262 £262 £262OPHF High Static Fan £17 £40 £40 £40 £82 £82 £82OPZH Chilled Water Down to -5 £167 £167 £167 £167 £167 £167 £167OPZL Chilled Water Down to -10 £167 £167 £167 £167 £167 £167 £167

Fitted Options:

Page 52: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial50

APP

LIED

Water Cooled Chillers

Water Cooled Packaged Scroll Compressor – R407C

EWWP014KBW1N 12.90 - 3-phase £2,909.00EWWP022KBW1N 21.40 - 3-phase £3,439.00EWWP028KBW1N 27.80 - 3-phase £3,951.00EWWP035KBW1N 32.30 - 3-phase £4,598.00EWWP045KBW1N 42.80 - 3-phase £5,664.00EWWP055KBW1N 55.70 - 3-phase £6,326.00EWWP065KBW1N 64.70 - 3-phase £7,065.00

Notes:i) Please contact your local sales office for further information on

these products

ii) Nominal cooling capacities are based on chilled water @ 12/7°C, condenser water @ 30/35°C

To Fit Model EWWP-KAW1NPart No Description 014 022 028 035 045 055 065OPZH Chilled Water Down to -5 £167 £167 £167 £167 £167 £167 £167OPZL Chilled Water Down to -10 £167 £167 £167 £167 £167 £167 £167

Fitted Options:

Cooling Capacity:ModelNo

Nominal CoolingkW

NominalHeatingkW

PowerSupply

TradePrice

Applied Systems Kit Options

Model Description Trade PriceBHGP26A1 Digital Pressure gauges - EWAQ/EWYQ-BA £268.00DTA104A62 External control adaptor Low noise & demand limit - EWAQ/EWYQ-BA £221.00EHMC10A10 HYDRAULIC MODULE -Normal static + anti-freeze protection - EWWP014~022/EWLP012~020 £1,668.00EHMC10A80 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP014~022/EWLP012~020 £1,775.00EHMC15A10 HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP028~035/EWLP026~030 £1,775.00EHMC15A80 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP028~035/EWLP026~030 £1,848.00EHMC30A10 HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP045~065/EWLP040~065 £1,991.00EHMC30A80 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP045~065/EWLP040~065 £1,991.00EKAC10C Address card for connection to BMS - EUWA/Y(N,P,B)5-24KBZW,EWWP,EWLP (note not available on the modular EWWP) £86.00EKRUMCA Remote Control- EUWA/Y(N,P,B)5-24KBZW,EWWP,EWLP (needs EKAC10C) £163.00EKBT Buffertank 200I - EUWA/Y5-24KBZW £1,097.00EKGAU10/12KA Gauges kit 10/12Hp-units - EUWA/Y10-12KBZW £167.00EKGAU16KA Gauges kit 16Hp-units - EUWA/Y16 KBZW £268.00EKGAU20/24KA Gauges kit 20/24Hp-units - EUWA/Y20-24KBZW £268.00EKGAU5/8KA Gauges kit 5/8Hp-units - EUWA/Y5-8KBZW £167.00EKLS1 Low noise operation EWLP012~EWWP14 £155.00EKLS2 Low noise operation EWLP02~030, EWWP22-35 £155.00EKLS2 X 2 Low noise operation EWLP040~065, EWWP45-65 £310.00EKRP1HBA Digital I/O PCB - EWAQ / EWYQ - AC £104.00EKRP1AHT Demand PCB / Inputs - EWAQ/EWYQ-BA (2 x on size 40/50/64) £107.00EKRUAHTB Remote user interface (in parallel) - EWAQ/EWYQ-BA £161.00RTD-W MODBUS Interface - EWAQ/EWYQ-BA £205.00

Loose Accessory Options:

Page 53: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 51

APP

LIED

Capacity conditionsEUROVENT conditionsCooling27°C db / 19°C wb - Entering water 7°C - Leaving water 12°C

Heating 4 Pipe20°C db - Entering water 70°C - Leaving water 60°C

Heating 2 Pipe 20°C db - Entering water 50°C - Flow rate as in cooling mode

TYPICAL UK cooling conditions22°C db / 16.0°C wb - Entering water 7°C - Leaving water 12°C0 Pa External Static Pressure0% Glycol

FWP & FWD Ducted FCU - Above capacities are based on 30 Pa External Static Pressure

FWS Uncased - Based on 20 pa external static

Fan Coil UnitsDaikin’s fan coil range are manufactured in Europe to the same high standard, high quality and reliability as their DX counterparts.

An extensive range of control and valve options are available to complement these quiet and fashionable units.

Page 54: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial52

APP

LIED

Cased Low Wall Mount Type 2-pipe FWZ02AT FWZ03AT FWZ06AT FWZ08ATCapacity UK Total Cooling kW 1.39 2.57 3.23 5.11

Nominal Cooling kW 2.64 4.96 6.32 10.08Nominal Heating kW 3.47 6.4 7.51 11.18

Dimensions Height mm 226 226 226 251Width mm 774 987 1194 1404Depth mm 564 564 564 564

Weight kg 20 25 31 41Sound Power High/Low dBA 62/28 70/28 64/28 71/28Sound Pressure High/Low dBA 54/20 62/20 56/20 63/20Air Flow Rate High m3/min 9.33 15 20 27.66Water Connections inch 1/2 1/2 1/2 3/4Electrical Data Power Supply 1ph

Trade Fan Coil Price £267.00 £283.00 £327.00 £407.00

Cased Low Wall Mount Type 4-pipe FWZ02AF FWZ03AF FWZ06AF FWZ08AFCapacity UK Total Cooling kW 1.39 2.57 3.23 5.11

Nominal Cooling kW 2.64 4.96 6.32 10.08Nominal Heating kW 2.46 4.19 6.45 10.06

Dimensions Height mm 226 226 226 251Width mm 774 987 1194 1404Depth mm 564 564 564 564

Weight kg 21 26 33 44Sound Power High/Low dBA 62/28 70/28 64/28 71/28Sound Pressure High/Low dBA 54/20 62/20 56/20 63/20Air Flow Rate High m3/min 9.33 15 20 27.66Water Connections inch 1/2 1/2 1/2 3/4Electrical Data Power Supply 1ph

Trade Fan Coil Price £291.00 £303.00 £366.00 £442.00

New BLDC (Brushless Direct Current) Inverter Driven Floor Standing Fan Coil Units

Cased Flexi Type 2-pipe FWR02AT FWR03AT FWR06AT FWR08ATCapacity UK Total Cooling kW 1.39 2.57 3.23 5.11

Nominal Cooling kW 2.64 4.96 6.32 10.08Nominal Heating kW 3.47 6.4 7.51 11.18

Dimensions Height mm 226 226 226 251Width mm 774 987 1194 1404Depth mm 564 564 564 564

Weight kg 21 27 33 44Sound Power High/Low dBA 62/28 70/28 64/28 71/28Sound Pressure High/Low dBA 54/20 62/20 56/20 63/20Air Flow Rate High m3/min 9.33 15 20 27.66Water Connections inch 1/2 1/2 1/2 3/4Electrical Data Power Supply 1ph

Trade Fan Coil Price £280.00 £301.00 £349.00 £445.00

Cased Flexi Type 4-pipe FWR02AF FWR03AF FWR06AF FWR08AFCapacity UK Total Cooling kW 1.39 2.57 3.23 5.11

Nominal Cooling kW 2.64 4.96 6.32 10.08Nominal Heating kW 2.46 4.19 6.45 10.06

Dimensions Height mm 226 226 226 251Width mm 774 987 1194 1404Depth mm 564 564 564 564

Weight kg 22 28 35 46Sound Power High/Low dBA 62/28 70/28 64/28 71/28Sound Pressure High/Low dBA 54/20 62/20 56/20 63/20Air Flow Rate High m3/min 9.33 15 20 27.66Water Connections inch 1/2 1/2 1/2 3/4Electrical Data Power Supply 1ph

Trade Fan Coil Price £305.00 £329.00 £388.00 £492.00

New BLDC (Brushless Direct Current) Inverter Driven Flexi Fan Coil Units

Page 55: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 53

APP

LIED

Concealed Flexi Type 2-pipe FWS02AT FWS03AT FWS06AT FWS08ATCapacity UK Total Cooling kW 1.08 2.02 2.52 3.99

Nominal Cooling kW 2.64 4.96 6.32 10.08Nominal Heating kW 3.47 6.4 7.51 11.18

Dimensions Height mm 224 224 224 249Width mm 584 794 1004 1214Depth mm 535 535 535 535

Weight kg 15 19 23 32Sound Power High/Low dBA 62/28 70/28 64/28 71/28Sound Pressure High/Low dBA 54/20 62/20 56/20 63/20Air Flow Rate High m3/min 9.33 15 20 27.66Water Connections inch 1/2 1/2 1/2 3/4Electrical Data Power Supply 1ph

Trade Fan Coil Price £239.00 £257.00 £293.00 £366.00

Concealed Flexi Type 4-pipe FWS02AF FWS03AF FWS06AF FWS08AFCapacity UK Total Cooling kW 1.08 2.02 2.52 3.99

Nominal Cooling kW 2.64 4.96 6.32 10.08Nominal Heating kW 2.46 4.19 6.45 10.06

Dimensions Height mm 224 224 224 249Width mm 584 794 1004 1214Depth mm 535 535 535 535

Weight kg 16 20 25 34Sound Power High/Low dBA 62/28 70/28 64/28 71/28Sound Pressure High/Low dBA 54/20 62/20 56/20 63/20Air Flow Rate High m3/min 9.33 15 20 27.66Water Connections inch 1/2 1/2 1/2 3/4Electrical Data Power Supply 1ph

Trade Fan Coil Price £265.00 £287.00 £329.00 £412.00

FWZ,FWR,FWS 02-03 06 082-pipe 3-way valve kits c/w lockshields E2MV03A6 E2MV06A6 E2MV10A6

£121.00 £121.00 £128.004-pipe 3-way valve kits c/w lockshields E4MV03A6 E4MV06A6 E4MV10A6

£217.00 £217.00 £227.00Vertical drainpan EDPVB6

£3.00Horizontal drainpan EDPHB6

£3.00Advanced Plus Electronic Controller FWEC3A

£114.00On board installation kit (FWZ & FWR - Low Wall Mounted Only)

FWECKA£11.00

Reurn Air Sensor FWTSKA£8.00

Loose Accessory Options: Notes:FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required)

Please note thati) Each controller version includes the

water probe

ii) The on board installation kit includes a remote air probe (If installed the internal fan coil robe is disabled)

iii) The FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required).

Floor Standing and Flexi Fan Coil Unit Accessories

New BLDC (Brushless Direct Current) Inverter Driven Low Static Concealed Flexi Fan Coil Units

Page 56: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial54

APP

LIED

Concealed Ducted Type 2-pipe FWP02-AT FWP03-AT FWP04-AT FWP05-AT FWP06-AT FWP07-ATCapacity UK Total Cooling kW 1.34 1.67 2.03 2.5 2.77 3.47

Nominal Cooling kW 2.61 3.14 3.49 5.08 5.45 6.47Nominal Heating kW 5.47 6.01 6.47 10.31 11.39 12.28

Dimensions Height mm 239 239 239 239 239 239Width mm 1039 1039 1039 1389 1389 1389Depth mm 609 609 609 609 609 609

Weight kg 24 26 28 33 35 38Sound Power High/Low dBA 56/40 56/40 56/40 61/39 61/39 61/39Sound Pressure High/Low dBA 44/24 44/24 44/24 50/27 50/27 50/27Air Flow Rate High m3/min 6.66 6.66 6.66 13.33 13.33 13.33Water Connections inch 3/4 3/4 3/4 3/4 3/4 3/4Electrical Data Power Supply 1ph

Trade Fan Coil Price - Naked - No Valve FWP02-ATN FWP03-ATN FWP04-ATN FWP05-ATN FWP06-ATN FWP07-ATN£344.00 £359.00 £373.00 £438.00 £443.00 £472.00

Trade Fan Coil Price- Complet with 3 - way valve fitted FWP02-ATV FWP03-ATV FWP04-ATV FWP05-ATV FWP06-ATV FWP07-ATV£422.00 £436.00 £450.00 £514.00 £519.00 £549.00

Please note if you require a 4 pipe fan coil please purchase additional heat exhanger as shown below

New BLDC (Brushless Direct Current) Inverter Driven Medium Static Ducted Fan Coil Units

FWP 02 - 04 05 - 07Additional Heat exchanger (4 Pipe) nominal heating cap 3.2kW

EAH04A6 -£89.00 -

Additional Heat exchanger (4 Pipe) nominal heating cap 6.1kW

- EAH07A6- £104.00

2-way valve cooling coil E2MV207A6£51.00

3-way valve add.h/e E2MV307A6£91.00

2-way valve add.h/e E2MV207A6£51.00

Advanced Plus Electronic Controller FWEC3A£114.00

Reurn Air Sensor FWTSKA£8.00

Loose Accessory Options: Notes: FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required)

Please note that:i) Each controller version includes the

water probe

ii) The FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required).

Page 57: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 55

APP

LIED

Concealed Ducted Type 2-pipe FWD04AT FWD06AT FWD08AT FWD10AT FWD12AT FWD16AT FWD18ATCapacity UK Total Cooling kW 2.15 3.48 4.44 4.92 7.21 8.96 9.91

Nominal Cooling kW 3.9 6.2 7.8 8.82 11.9 16.4 18.3Nominal Heating kW 4.05 7.71 9.43 10.79 14.45 19.81 21.92

Dimensions Height mm 280 280 280 280 352 352 352Width mm 754 964 1174 1174 1174 1384 1384Depth mm 559 559 559 559 718 718 718

Weight kg 33 41 47 49 65 77 80Sound Power High / Low dBA 66/54 69/59 72/62 72/62 74/60 78/69 78/69Sound Pressure High / Low dBA 56/46 61/51 64/54 64/54 66/52 70/61 70/61Air Flow Rate High m3/min 13.33 20.83 26.67 26.67 36.67 50 50Water Connections inch 3/4 3/4 3/4 3/4 1 1 1 Electrical Data Power Supply 1ph

Trade Fan Coil Price £270.00 £355.00 £415.00 £462.00 £574.00 £735.00 £808.00

Concealed Ducted Type 4-pipe FWD04AF FWD06AF FWD08AF FWD10AF FWD12AF FWD16AF FWD18AFCapacity UK Total Cooling kW 2.15 3.48 4.44 4.92 7.21 8.96 9.91

Nominal Cooling kW 3.9 6.2 7.8 8.82 11.9 16.4 18.3Nominal Heating kW 4.05 7.71 9.43 10.79 14.45 19.81 21.92

Dimensions Height mm 280 280 280 280 352 352 352Width mm 754 964 1174 1174 1174 1384 1384Depth mm 559 559 559 559 718 718 718

Weight kg 35 43 50 52 71 83 86Sound Power High / Low dBA 66/54 69/59 72/62 72/62 74/60 78/69 78/69Sound Pressure High / Low dBA 56/46 61/51 64/54 64/54 66/52 70/61 70/61Air Flow Rate High m3/min 13.33 20.83 26.67 26.67 36.67 50 50Water Connections inch 3/4 3/4 3/4 3/4 1 1 1 Electrical Data Power Supply 1ph

Trade Fan Coil Price £316.00 £413.00 £482.00 £545.00 £672.00 £853.00 £935.00

High Static Ducted Fan Coil Units

FWD 4 6 8 -10 12 16 -182-pipe 3-way valve ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6

£128.00 £128.00 £128.00 £133.004-pipe 3-way valve ED4MV04A6 ED4MV10A6 2x ED2MV12A6 2 x ED2MV18A6

£244.00 £244.00 £256.00 £266.00Vertical Drain pan EDDPV10A6 EDDPV18A6

£11.00 £11.00Horizontal Drain Pan EDDPH10A6 EDDPH18A6

£13.00 £13.00Master slave interface EPIMSA6 -

£84.00 -Power interface (S) EPIB6

£84.00Standard Electronic Controller FWEC1A

£65.00Advanced Electronic Controller FWEC2A

£82.00Advanced Plus Electronic Controller FWEC3A

£114.00Return Air Sensor FWTSKA

£8.00

Loose Accessory Options: Notes: FWEC1A is designed as an individual unit controller. Power interface EPIB6 is required for unit size 16 and 18 can operate up to 4 fan coils by adding a EPIMSA6.

If using this controller to operate up to 4 fan coil units by adding a EPIMSA6 you will require a EPIB6 power interface for unit size 12,16,18.

FWEC2A can operate up to 247 fan coils as master slave control ( 1 per fan coil required). Power interface EPIB6 is required for each unit size 16 and 18.

FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control (by others) and 2 digital outputs ( 1 per fan coil required).

Please note that:i) Each controller version includes the

water probe.

Page 58: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial56

APP

LIED

600sq Cassette Type 2-pipe c/w Decoration Panel BYFQ60B FWF02BT FWF03BT FWF04BT FWF05BTCapacity UK Total Cooling kW 1.20 1.9 2.5 3.1

Nominal Cooling kW 2 3.2 4.2 5.2Nominal Heating kW 2.9 4 5.4 6.7

Dimensions Height mm 260 260 260 260Width mm 575 575 575 575Depth mm 575 575 575 575

Weight kg 19 19 19 19Sound Power High / Low dBA 44/36 44/36 50/36 55/42Sound Pressure High / Low dBA 31/26 31/26 40/26 45/30Air Flow Rate High m3/min 7.9 7.9 11.2 14.9Water Connections inch 3/4 “ BSP FemaleElectrical Data Power Supply 1 ph

Trade Fan Coil Price £509.00 £535.00 £565.00 £603.00

600sq Cassette Type 4-pipe c/w Decoration Panel BYFQ60B FWF02BF FWF03BF FWF04BF FWF05BFCapacity UK Total Cooling kW 1.10 1.6 2 2.5

Nominal Cooling kW 2 2.7 3.5 4.5Nominal Heating kW 3.9 3.8 4.9 6.1

Dimensions Height mm 260 260 260 260Width mm 575 575 575 575Depth mm 575 575 575 575

Weight kg 19 20 20 20Sound Power High / Low dBA 44/36 44/36 50/36 55/42Sound Pressure High / Low dBA 31/26 31/26 40/26 45/30Air Flow Rate High m3/min 7.9 7.2 10.4 13.9Water Connections inch 3/4 “ BSP FemaleElectrical Data Power Supply 1 ph

Trade Fan Coil Price £541.00 £565.00 £603.00 £637.00

600 Sq Cassette Fan Coil Units

Cassette Type 2-pipe c/w Decoration Panel BYCQ140C FWC06BT FWC07BT FWC08BT FWC09BTCapacity UK Total Cooling kW 3.30 4.1 4.3 4.8

Nominal Cooling kW 5.8 6.8 7.7 8.7Nominal Heating kW 8 8.9 10.6 12.1

Dimensions Height mm 288 288 288 288Width mm 840 840 840 840Depth mm 840 840 840 840

Weight kg 26 26 26 26Sound Power High / Low dBA 43/31 47/33 53/36 57/40Sound Pressure High / Low dBA 29/21 33/22 39/24 43/28Air Flow Rate High m3/min 17.7 20.6 25.4 30.8Water Connections inch 3/4 “ BSP FemaleElectrical Data Power Supply 1 ph

Trade Fan Coil Price £621.00 £637.00 £653.00 £681.00

Cassette Type 4-pipe c/w Decoration Panel BYCQ140C FWC06BF FWC07BF FWC08BF FWC09BFCapacity UK Total Cooling kW 3.30 4 4.3 4.8

Nominal Cooling kW 5.8 6.6 7.6 8.7Nominal Heating kW 7.5 8.4 9.7 11

Dimensions Height mm 288 288 288 288Width mm 840 840 840 840Depth mm 840 840 840 840

Weight kg 29 29 29 29Sound Power High / Low dBA 43/31 47/33 53/36 57/40Sound Pressure High / Low dBA 29/21 33/22 39/24 43/28Air Flow Rate High m3/min 17.1 19.9 24.6 29Water Connections inch 3/4 “ BSP FemaleElectrical Data Power Supply 1 ph

Trade Fan Coil Price £649.00 £673.00 £691.00 £708.00

Cassette Fan Coil Units

Page 59: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 57

APP

LIED

FWF/FWC FWF/FWCRemote wired controller (requires KJB212A) BRC315D

£67.00Intelligent touch controller DCS601C51

£1,641.00Unit/Group adapter pcb KRP4A53

£67.00Unit/Group adapter pcb complete with installation box

KRP4A53/UK.FB2£92.00

System adaptor pcb KRP2A52£177.00

System adaptor pcb complete with installation box

KRP2A52/UK.FB2£202.00

Optional pcb for connection to ModBus EKFCMBCB£55.00

2-Way on / off valve kit EKMV2C09B£58.00

3-Way on / off valve kit EKMV3C09B£64.00

Valve control PCB EKRP1C11£100.00

FWC only FWC onlyWireless remote control heat pump BRC7FA532F

£152.00Wireless remote control cooling only BRC7F533F

£152.00Remote air sensor KRCS01-4

£47.00Installation box for an EKRP1C11 valve PCB KRP1H98

£37.00

FWF only FWF onlyWireless remote control heat pump BRC7E530

£121.00Wireless remote control cooling only BRC7E531

£121.00System adaptor pcb KRCS01-1

£46.00Remote on/off control interface kit EKRORO

£16.00Installation box for an EKRP1C11 valve PCB KRP1BA101

£43.00

Loose Accessory Options: Notes:i) FWF and FWC Cassette Fan Coil prices

include decoration panel

ii) It is not possible to use Intelligent Touch control for combination with both VRV and water based fan coils

FWF-Valve control requirements 2 pipe unit: 1 x valve kit + 1 x installation

box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11

4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11

FWC-Valve control requirements 2 pipe unit: 1 x valve kit + 1 x installation

box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11

4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11

Cassette Accessories

Cased High Wall Mount Type 2-pipe FWT02CT FWT03CT FWT04CT FWT05CT FWT06CTCapacity UK Total Cooling kW 1.59 1.67 2.1 2.9 3.41

Nominal Cooling kW 2.43 2.7 3.31 4.54 5.28Nominal Heating kW 3.22 3.52 4.4 6.01 5.26

Dimensions Height mm 288 288 288 310 310Width mm 800 800 800 1065 1065Depth mm 206 206 206 224 224

Weight kg 10 10 10 15 15Sound Power High / Low dBA 45/36 48/39 55/45 55/47 59/51Sound Pressure High / Low dBA 34/25 35/25 42/32 42/34 42/39Air Flow Rate High m3/min 7.36 7.93 10.48 14.43 17.55Water Connections inch 1/2 1/2 1/2 1/2 1/2Electrical Data Power Supply 1ph

Trade Fan Coil Price £196.00 £204.00 £234.00 £283.00 £301.00

Wall Mounted Fan Coil Units

FWT FWTStandard wired remote controller MERCA

£76.00Simplified wired remote controller SRC-HPA

£39.00Wireless controller for heat pump WRC-HPB

£15.00

Loose Accessory Options: Notes:i) FWT fan coils are optimised for valveless

control in cooling. We would recommend that a valve is fitted if being used for heating only and for more precise control in cooling.

ii) We would recommend the field supply of a 240V - 4 port 3 way valve complete with 240V actuator.

Page 60: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

APP

LIED

Page 61: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

MIS

CELL

AN

EOU

S

MiscellaneousSchematics 60

Malfunction Codes 61

Terms & Conditions 62

Price List 2014 59

Page 62: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial60

MIS

CELL

AN

EOU

S

Wiring DiagramSplit & Sky Air Interconnecting Wiring

Wiring Adaptor for External ControlKRP4A51-52-53-54

* Except RX50-71, RXS42-71 & RXG50 which require 2.5mm 4 core interconnecting wiring

*

Page 63: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 61

MIS

CELL

AN

EOU

S

Wiring Adaptor for External ControlKRP4A51-52-53-54

Overall Malfunction Display on Daikin LCD Controller2nd

1st 0 1 2 3 4 5 6 7 8 9 A C E F H J

Indo

or

AProtection

Device Activated (General)

Faulty Indoor PCB Abnormal Drain H2O Level

Abnormal Heat Exchanger 1 Temperature

Abnormal Heat Exchanger 2 Temperature

Fan Motor Overload & Over

Current Lock

Air Swing Motor Lock

AC Input Over Current

Faulty Electronic Expansion Valve

Backup Heater Thermal Protector

Activated

Booster Heater Thermal Protector

Insufficient Water Supply Faulty Humidifier Faulty Or Dirty

Dust Collector

Faulty Capacity Setting Plug

(Indoor)

C Flow Switch Abnormality

Failure of Transmission

Between Indoor Unit & Sub PCB’s

Faulty Drain H2O Level Sensor

System

Malfunction of Liquid Pipe Thermisor for

Heat Exchanger

Malfunction of Gas Pipe

Thermisor for Heat Exchanger

Fan Motor OL/OC, Lock Sensor Incorrect

combination Fandrive/Set

Air Swing Motor Lock Faulty Sensor

System

Faulty AC Input Current Sensor

System.

Malfunction of Suction Air

Thermisor

Malfunction of Discharge Air

Thermistor

Malfunction of Humidity Sensor

System

Malfunction of Switch Box

Thermistor

Faulty High Pressure Switch

Malfunction of Thermistor

in Remote Controller

Out

door

ESafety Device

Activation (General)

Faulty Outdoor PCB

Activation of High Pressure Switch

(HPS)

Activation of Low Pressure Switch

(LPS)

Activation of Inverter Compressor

Motor Overload

Compressor Over Current Lock

Fan Motor OL.OC. Lock

OC of Inverter Compressor

Faulty Electronic Expansion Valve

Malfunction of 4-Way Valve Cool/

Heat Switching

Abnormal Water Temperature

Faulty Drain H2O Level System

Faulty Heat Storage Unit Pump OC. Lock

Activation Of Local Safety

Device

FActivation Safety

Device (Syst.No.1)

Activation Safety Device (Syst.

No.2)

Faulty Discharge Pipe Temperature

Malfunction of Suction Pipe Thermistor

Abnormal High Pressure or Refrigerant

Overcharge

Expansion Valve faulty In BSVQ-P

Abnormal discharge pressure

Abnormal suction pressure

Abnormal Oil Pressure

Abnormal Oil Surface Level

Abnormal High Oil Temperature

H Voltage & Current Sensor Failure

Faulty Air Temperature

Sensor System Damper Fail

Faulty Power Supply Sensor

System

Faulty High Pressure Switch

(HPS)

Faulty Low Pressure Switch

(LPS)

Compressor Motor Faulty OL. Sensor

System

Compressor Motor OC. Lock Faulty Sensor System

Fan Motor OL OC, Faulty Lock Sensor

System

Faulty AC Input Power Sensor

System

Malfunction of Outdoor Air

Thermistor

Malfunction of Discharge Air

Thermistor

Malfunction of Domestic Hot

Water Tank Thermistor

Faulty drain H2O level Sensor

System

Heat Storage Unit Alarm

Float switch (local supply) Open (if

Mode 2-26)

JFaulty Refrigerant

Temperature Sensor System

Malfunction of Pressure Sensor

Faulty Current Sensor System

Malfunction of Discharge Pipe

Thermistor

Faulty LP Equiv. Sat. Temperature

Sensor System

Malfunction of Suction Pipe Thermistor

Faulty Heat Exchanger 1 Temperature

Sensor System

Faulty Heat Exchanger 2 Temperature

Sensor System

Faulty Liquid Pipe Temperature

Sensor System

Faulty Gas Pipe Temperature

Sensor System

Faulty Discharge Pressure Sensor

System

Faulty Suction Pressure Sensor

System

Faulty Oil Pressure Sensor System

Malfunction of Oil Level Sensor

or Heating HeatX thermistor

Faulty Oil Temperature

Sensor System

L Faulty Inverter System

Malfunction of Inverter PCB

Abnormal Temperature Rise

In Switch Box

Abnormal Temperature Rise

Radiation Fin Thermistor

Inverter Instantaneous OC

(DC output)

Inverter Instantaneous OC

(AC output)

Inverter Compressor OC

Detection

Compressor Stall Prevention

Faulty power transistor

Malfunction of Transmission

Between Control & Inverter PCB

P Gas Short. ice thermal stor. Eqp.

Missing Phase. Unbalanced

Power Supply

Auto charge Stopped At Step 5 BS4 Not Pushed

Malfunction of Thermistor in

Switch Box

Faulty Radiant Fin Temperature Sensor System

Faulty DC Current Sensor System

Faulty AC or DC Output Current Sensor System

Malfunction of Total Input

Current Sensor

Autocharge Should Be Restarted

Autocharge Judgement: Finished OK

Replace Charge Cylinder “Master”

Replace Charge Cylinder “Slave 2”

Auto charge Almost finished

Leak Test not poss w/o input add

charge

Replace Charge Cylinder “Slave 1”

Faulty Capacity Setting Plug

(Outdoor)

Syst

em

U Shortage of Refrigerant

Reversed or Open Phase Connected

Faulty Power Supply Voltage

System

Faulty Transmission

or Test Run Not Executed

Faulty Transmission

Indoor ↔ Outdoor Units

Faulty Transmission.

Indoor Unit ↔ Remote Control

Faulty Transmission Indoor Units (Master ↔

Slave)

Malfunction of Transmission

between Outdoor Units

Faulty Transmission

between Remote Controllers

Malfunction of Transmission

between Indoor/Outdoor Unit in Same System

Faulty On Site Setting

Address Duplication or

Incorrect Setting

Faulty Transmission Indoor Unit

↔ Centralised Control

Incorrect Wiring/Piping (Wiring/

Piping Connection Error)

Indoor/Outdoor unit address not

entered

Fault communication

to/from peripheral equipment

MMalfunction

of Centralised Remote Controller

PCB

Malfunction of Transmission ↔

Optional Controller for Centralised

Control

Improper Comb. of Optional

Controllers for Centralised

Control

Address Duplication /

Improper Setting

Oth

er

6HRV External

Protection Device Activated

Faulty PCB Abnormal Ozone Concentration Faulty dirt sensor

Malfucntion of Thermistor for Indoor Air HRV

Malfunction of Thermistor for

Outdoor Air HRV

Malfunction of Damper System

HRV

Humidifier Element

Replacement

Replace the Deodorising

Catalyst

Simplified Remote Control

Malfunction HRV

Door Switch Open HRV

Replace High-Efficiency Filter

7System no. 2 Compressor

Overheat

System no. 2 Compressor Over

Current

System no.2 Fan Motor Over

Current

System no. 2 Activation of HP

Switch

System no. 2 Activation of LP

Switch

System no. 2 Malfunction of LP

sensor

System no. 2 Malfunction of HP

sensor

System no. 1 Malfunction of Fan Interlock (defect of

relay contact)

System no. 2 Malfunction of Fan Interlock (defect of

relay contact)

System no. 2 Malfunction

of Compressor Current Sensor

Malfunction of Pump Interlock

Flow Failure Insufficient Water

Flow

8Inlet Water

Temperature Thermistor

Outlet Water Temperature Thermistor

System no. 1 Malfunction

of Refrigerant Thermistor

System no. 2 Malfunction

of Refrigerant Thermistor

System no. 1 Malfunction of Heat Exchange

Thermistor

System no. 2 Malfunction of Heat Exchange

Thermistor

System no. 1 Malfunction of Discharge Pipe

Thermistor

System no. 2 Malfunction of Discharge Pipe

Thermistor

Heat Exchanger Freeze Up

Malfunction of Leaving Water Temperature Thermistor

System no. 1 Malfunction of Suction Pipe Thermistor 1 for

Heating

System no. 1 Malfunction of Suction Pipe Thermistor 2 for

Heating

Outlet Water Temperature Thermistor

9 Low Water Volume Detection

System no. 2 Defect of EEV Coil

System no. 2 Defect of Suction Pipe Thermistor

Malfunction of Transmission

HRV ↔ Indoor Fan Units

System no. 1 Malfunction

of Fan Inverter System

System no. 2 Malfunction

of Fan Inverter System

Defect of Thermal Storage Unit

Thermal Storage Unit Brine Pump O/C

Thermal Storage Brine Tank Low

Water Level

System no. 2 Malfunction of Suction Pipe Thermistor 1 for

Heating

System no. 2 Malfunction of Suction Pipe Thermistor 2 for

Heating

Caution: Some displayed malfunction codes may have another meaning. Consult the relevant service manual for details.

Page 64: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial62

MIS

CELL

AN

EOU

S

HAWCO – Terms and Conditions of Sale to Business Customers

1. INTERPRETATION

In these conditions the following words have the following meanings:

You or Your: the person(s), firm or company who purchases the Goods from Us or to whom We supply Services;

We, Us, Our or Ourselves: Hawco Limited registered under company number 01537960 whose registered office is at The Wharf Abbey Mill Business Park Lower Eashing Godalming Guildford Surrey GU7 2QN, trading as HAWCO;

Contract: any contract between Us and You for the sale and purchase of the Goods or for the supply of Services by Us to You, incorporating these Conditions

Goods: any goods agreed in the Contract to be supplied to You by Us (including any part or parts of them);

Services: any services agreed in the Contract to be supplied to You by Us and any other advice given by Us to You.

2. APPLICATION OF TERMS

2.1 Subject to any variation under condition 2.4 the Contract will be on these conditions to the exclusion of all other terms and conditions (including any terms or conditions which You purport to apply under any purchase order, confirmation of order, specification or other document).

2.2 No terms or conditions endorsed upon, delivered with or contained in Your purchase order, confirmation of order, specification or other document will form part of the Contract simply as a result of such document being referred to in the Contract.

2.3 The Contract constitutes the entire agreement between the parties. You acknowledge that You have not relied on any statement, promise or representation made or given by or on Our behalf which is not set out in the Contract. All drawings, descriptive matter, specifications and advertising issued by Us and any descriptions or illustrations contained in Our catalogues or brochures are issued or published for the sole purpose of giving an approximate idea of the Goods and Services described in them. They will not form part of this Contract or any other contract between us.

2.4 These conditions apply to all Our sales and any variation to these conditions and any representations about the Goods or Services shall have no effect unless expressly agreed in writing and signed by one of Our directors.

2.5 Each order for Goods or Services by You from Us shall be deemed to be an offer by You to purchase Goods or Services subject to these conditions.

2.6 No order placed by You shall be deemed to be accepted by Us until:

(a) a written acknowledgement of order is issued by Us; or

(b) in the case of orders placed online, We telephone You to confirm acceptance of Your Order; or

(c) (if earlier) We deliver the Goods to You or supply the Services to You.

2.7 You must ensure that the terms of Your order and any applicable specification are complete and accurate.

2.8 Any quotation for the Goods and Services shall not constitute an offer. Any quotation is valid for a period of 30 days only from its date, provided that We have not previously withdrawn it.

2.9 Any samples submitted by Us must be returned to Us, carriage paid, within one month of the date of despatch by Us, or paid for.

2.10 No order which has been accepted by Us may be cancelled by You except with Our agreement in writing and on terms that You shall indemnify Us in full against all loss (including loss of profits), costs (including cost of all labour and materials used), damages, charges and expenses incurred by Us as a result of cancellations.

2.11 Any order valued below £50.00 (ex VAT) will have a standard £15.00 minimum order surcharge applied to each delivery, covering delivery by next day carrier, packing, insurance and administration.

3. DESCRIPTION

3.1 The description of the Goods or Services shall be as set out in Our quotation.

3.2 We reserve the right to make changes in the specification of the Goods or Services which are required to conform with any applicable safety or other statutory requirements or, where the Goods or Services are to be supplied to Your specification, which do not materially affect their quality or performance.

3.3 If Goods are altered, assembled or adapted to Your design or specification or any processes are to be applied to the Goods by Us in accordance with a design or specification submitted by You, You represent and warrant that You have all necessary rights to instruct Us to do so and shall indemnify Us against all loss, damages, costs and expenses awarded against or incurred by Us in connection with or paid or agreed to be paid by Us in settlement of any claim for infringement of any patent, copyright, design, trademark or other industrial or intellectual property rights of any other person which results from Our use of Your design or specification.

3.4 Any specification supplied by Us to You in connection with the Contract, together with the copyright, design rights or any other intellectual property rights in the specification shall be Our exclusive property. You shall not disclose to any third party or use any such specification except to the extent that it becomes public knowledge through no fault of Yours, or as required for the purpose of the Contract.

4. DESPATCH AND DELIVERY

4.1 Unless otherwise agreed, delivery of the Goods shall take place at Your place of business.

4.2 While every reasonable effort will be made to fulfil delivery dates, any dates quoted for delivery of the Goods are approximate only and We shall not be liable for any delay in delivery of the Goods however caused but the following provisions shall have effect:

(a) time for delivery shall not be of the essence of the Contract;

(b) in the event that the delay exceeds 180 days after the agreed delivery date, the parties shall meet to discuss a revised date for delivery. In absence of any agreement, You shall be entitled to terminate or rescind the Contract in so far as it relates to the delivery consignment in question;

(c) the foregoing provisions shall be Your exclusive remedy in respect of such delay in delivery.

4.3 Scheduled deliveries can only be agreed during a period commencing no sooner than one month and terminating no later than 12 months from the date of the order. At least 30 days written notice is required of any modification or suspension of scheduled deliveries. Any suspension will be limited to a maximum period of 3 months after which deliveries may be resumed at the former rate.

4.4 If You fail to take delivery of the Goods or fail to give Us adequate delivery instructions at the time stated for delivery (otherwise than by reason of any cause beyond Your reasonable control or by reason of our fault) then without prejudice to any right or remedy available to Us, We may:

(a) store the Goods until actual delivery and charge You for the reasonable costs (including insurance) of storage, and charge You also interest as provided in clause 10.6 on the delayed payment until such payment in full is made (a part of a month being treated as a full month for the purpose of calculating interest); or

(b) sell the Goods at the best price readily obtainable and (after deducting all reasonable storage and selling expenses) account to You for the excess over the price under the Contract or charge You for any shortfall below the price under the Contract.

4.5 Once delivered no Goods may be returned to Us without Our prior written consent.

4.6 Subject at all times to clause 4.2, any order delivered by pallet carrier, will be sent on a 3 day service (delivery within 3 days). A next day service can be requested when an order is placed and You will be charged at the appropriate requested service rate. Smaller orders sent on free delivery basis will be sent via a parcel carrier on a next day before 5.00 p.m. service. You may request an enhanced delivery service when You place an order and if We in Our absolute discretion accept Your request We will confirm the estimated time for delivery and You will be charged at the appropriate requested service rate.

4.7 You shall not be entitled to reject the Goods if We deliver up to and including 5% more or less than the quantity of Goods ordered, but a pro rata adjustment shall be made to Order invoice on receipt of notice from You that the wrong quantity of Goods was delivered.

4.8 We may deliver the Goods by instalments, which shall be invoiced and paid for separately. Each instalment shall constitute a separate Contract. Any delay in delivery or defect in an instalment shall not entitle the Customer to cancel any other instalment.

4.9 Where necessary You shall inform the Us at a reasonable time before delivery abroad, of any documents which it is necessary for Us to provide in order to allow export or import of Goods in compliance with the laws of any relevant jurisdiction.

5. NON-DELIVERY

5.1 The quantity of any consignment of Goods as recorded by Us upon despatch from Our works shall be conclusive evidence of the quantity received by You on delivery unless You can provide conclusive evidence proving the contrary. In any event shortage claims will only be considered if the carrier and Ourselves receive written notice of such shortage within three days of delivery.

5.2 We shall not be liable for any non-delivery of Goods unless written notice is given to Us within 3 days of the date when the Goods would in the ordinary course of events have been received.

5.3 Our liability for non-delivery of the Goods shall be limited to replacing the Goods within a reasonable time or issuing a credit note at the pro rata Contract rate against any invoice raised for such Goods.

Page 65: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Price List 2014 63

MIS

CELL

AN

EOU

S

6. TESTS

Subject at all times to clause 3.4, We will carry out tests on the Goods at Our works before despatch if We agree to provide any Services to alter or apply processes to the Goods and the manufacturer recommends that we carry out such tests. If such tests are required, these will be carried out solely in accordance with the manufacturer’s instructions and unless otherwise agreed, must be made at Our works and will be charged for in addition to the Contract price, and in the event of any delay on Your part in attending such tests after seven days notice that We are ready, the tests will proceed in Your absence, and shall be deemed to have been made in Your presence. We are not liable under the warranties in condition 11.2 for defects in samples of Goods made available for testing.

7. RISK/TITLE

7.1 The Goods are at the risk of the Buyer from the time of delivery.

7.2 Ownership of the Goods shall not pass to You until we have received in full (in cash or cleared funds) all sums due to Us in respect of:

(a) the Goods; and

(b) all other sums which are or which become due to Us from You on any account.

7.3 Until ownership of the Goods has passed to You, You must:

(a) hold the Goods on a fiduciary basis as Our bailee;

(b) not incorporate the Goods into or amalgamate the Goods with any other product;

(c) store the Goods (at no cost to Us) separately from all Your other goods or those of any third party in such a way that they remain readily identifiable as Our property;

(d) not destroy, deface or obscure any identifying mark or packaging on or relating to the Goods; and

(e) maintain the Goods in a satisfactory condition and keep them insured on Our behalf for their full price against all risks to Our reasonable satisfaction. On request You shall produce the policy of insurance to Us; and

(f ) hold the proceeds of the insurance referred to in condition 7.3(e) on trust for Us and not mix them with any other money, nor pay the proceeds into an overdrawn bank account.

7.4 You may resell the Goods before ownership has passed to You solely on the following conditions:

(a) any sale shall be effected in the ordinary course of Your business at full market value; and

(b) any such sale shall be a sale of Our property on Your own behalf and You shall deal as principal when making such a sale.

7.5 We shall be entitled to recover payment for the Goods notwithstanding that ownership of any of the Goods has not passed from Us.

7.6 You grant Us, Our agents and employees an irrevocable licence at any time to enter any premises where the Goods are or may be stored in order to inspect them, or, if before title to the Goods passes to You and You become subject to any of the events listed in clause 8.2 or We reasonably believe that any such event is about to happen and notify You accordingly, then, provided the Goods have not been resold, and without limiting any other right or remedy We may have We or Our agents and employees may at any time require You to delivery up the Goods and, if you fail to do so, enter any of Your premises or premises of any third party where the Goods are stored in order to recover them.

8. CUSTOMER’S INSOLVENCY OR INCAPACITY

8.1 If You become subject to any of the events listed in clause 8.2, or We reasonably believe that You are about to become subject to any of them and notify You accordingly, then, without limiting any other right or remedy available to Us, We may cancel or suspend all further deliveries under the Contract or under any other contract between us without incurring any liability to You, and all outstanding sums in respect of Goods delivered to the Customer shall become immediately due.

8.2 For the purposes of clause 8.1, the relevant events are:

(a) Your suspension, or threatened suspension, of payment of Your debts or are unable to pay Your debts as they fall due or You admit inability to pay Your debts or (being a company) You are deemed unable to pay Your debts within the meaning of section 123 of the Insolvency Act 1986, or (being an individual) You are deemed either unable to pay Your debts or have no reasonable prospect of so doing, in either case, within the meaning of section 268 of the Insolvency Act 1986; or

(b) You commence negotiations with all or any class of Your creditors with a view to rescheduling any of Your debts, or make a proposal for or enter into any compromise or arrangement with Your creditors other than (where You are a company) these events take place for the sole purpose of a scheme for Your solvent amalgamation with one or more other companies or Your solvent reconstruction; or

(c) (being an individual) You are the subject of a bankruptcy petition or order; or

(d) any of Your creditors or encumbrancers attaches or takes possession of, or a distress, execution, sequestration or other such process is levied or enforced on or sued against, the whole or any part of Your assets and such attachment or process is not discharged within 14 days; or

(e) (being a company) an application is made to court, or an order is made, for the appointment of an administrator or if a notice of intention to appoint an administrator is given or if an administrator is appointed over You; or

(f ) (being a company) a floating charge holder over Your assets becomes entitled to appoint or has appointed an administrative receiver; or

(g) a person becomes entitled to appoint a receiver over Your assets or a receiver is appointed over Your assets; or

(h) any event occurs, or proceeding is taken, in relation to You in any jurisdiction that has an effect equivalent or similar to any of the events mentioned in clause 8.2(a) to clause 8.2(g) (inclusive); or

(i) You suspend, threaten to suspend, cease or threaten to cease to carry on all or substantially the whole of Your business; or

(j) (being an individual) You die or, by reason of illness or incapacity (whether mental or physical), are incapable of managing Your own affairs or You become a patient under any mental health legislation.

9. PRICE

9.1 The price for the Goods or Services shall be the price set out in the order, or if no price is quoted, the price for the Goods and Services shall be the price set out in Our price list published on the date of delivery or deemed delivery.

9.2 The price for the Goods and Services shall be exclusive of any value added tax and all costs or charges in relation to packing, loading, unloading, carriage, import or export duties, and insurance all of which amounts You will pay in addition when You are due to pay for the Goods.

9.3 We may, by giving You notice at any time before delivery, increase the price of the Goods to reflect any increase in the cost of the Goods that is due to:

(a) any factor beyond Our control (including foreign exchange fluctuations, increases in taxes and duties, and increases in labour, materials and other manufacturing costs);

(b) any request by You to change the delivery date(s), quantities or types of Goods ordered, or the where relevant, the specification; or

(c) any delay caused by Your instructions or failure to give Us adequate or accurate information or instructions.

9.4 We may invoice You for the Goods or Services on or at anytime after the Goods are delivered or deemed to be delivered or the Services are supplied.

10. PAYMENT

10.1 Unless otherwise agreed in writing, payment of the price for the Goods and Services is due in pounds sterling on the earlier of 30 days from the date of Our invoice or on the last working day of the month following the month in which the Goods are delivered or deemed to be delivered or the Services are supplied.

10.2 Time for payment shall be of the essence.

10.3 No payment shall be deemed to have been received until We have received cleared funds.

10.4 All payments payable to Us under the Contract shall become due immediately upon termination of this Contract despite any other provision.

10.5 You will make all payments due under the Contract in full without any deduction whether by way of set-off, counterclaim, discount, abatement or otherwise unless You have a valid court order requiring an amount equal to such deduction to be paid by Us to You. We may at any time, without limiting any other right or remedies We may have, set off any amount owed to You against any amount payable by You.

10.6 If you fail to pay Us any sum due pursuant to the Contract You will be liable to pay interest to Us on such sum from the due date for payment at the annual rate of 4% above the base lending rate from time to time of Barclays Bank plc, accruing on a daily basis until payment is made, whether before or after any judgment. You will pay interest together with the overdue amount.

10.7 We may invoice You for the Goods on or at ant time after the completion of delivery.

11. QUALITY

11.1 We are not the manufacturer of the Goods, but will endeavour to transfer to You the benefit of any warranty or guarantee given to Us by the manufacturer and to the extent that this is not possible or if We alter the Goods in accordance with Your specification We will provide You with the warranty in clause 11.2. For the avoidance of doubt, the warranty in clause 11.2 will not apply if We transfer the benefit of the manufacturer’s guarantee to You.

11.2 No liability can be accepted for any failure of the Goods to perform according to any performance figures given. Subject thereto, and to clauses 11.1, 11.7, 11.8, and 11.9. We warrant that (subject to the other provisions of these conditions) upon delivery and for a period of 6 months from the date of delivery, the Goods will:

(a) be of satisfactory quality within the meaning of the Sale of Goods Act 1979;

(b) be free from material defects in design, material and workmanship;

(c) confirm in all material respective with their description.

Page 66: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Residential, Commercial and Industrial64

MIS

CELL

AN

EOU

S

(d) subject at all times to clause 11.5, be reasonably fit for any particular purpose for which the Goods are being bought if you had made known that purpose to us in writing and we have confirmed in writing that it is reasonable for you to rely on our skill and judgement.

11.3 We will not be liable for a breach of the warranties in condition 11.2 unless:

(a) You give Us written notice of the defect, and (if the defect is as a result of damage in transit) to the carrier, within 7 days of the time when You discover or ought to have discovered the defect; and

(b) We are given a reasonable opportunity after receiving the notice of examining such Goods and You (if asked to do so by Us) return such Goods to Our works at Our cost for the examination to take place there.

11.4 We will not be liable for a breach of the warranties in condition 11.2 if:

(a) You make any further use of such Goods after giving such notice; or

(b) any fault is due to:

(I) any specification or any materials You supply to Us; or

(II) Your instructions in relation to the processes to be applied to the Goods;

(III) your choice of components for the Goods.

(c) any damage or fault due to Your assembly or incorporation of the Goods any other products or is as a result of your choice of components for the Goods.

(d) the defect arises because You failed to follow Our oral or written instructions as to the storage, installation, commissioning, use or maintenance of the Goods or (if there are none) good trade practice; or

(e) You alter or repair such Goods without Our written consent.

11.5 Subject to conditions 11.1, 11.3 and 11.4, if any of the Goods do not conform with the warranties in condition 11.2 we will at Our option repair or replace such Goods (or the defective part) or refund the price of such Goods at the pro rata Contract rate provided that, if we so request, You will, at Our expense, return the Goods or the part of such Goods which is defective to Us.

11.6 If We comply with condition 11.5 We shall have no further liability for a breach of the warranties in condition 11.2 in respect of such Goods.

11.7 We warrant that any Services We provide will be provided using reasonable skill and care and, subject to clause 3.4, shall be in accordance with the specification You provide in all material respects.

11.8 We shall be under no liability in respect of any defect in the Goods arising from any drawing, design or specification supplied by You.

11.9 We shall be under no liability under the warranties in condition 11.2 (or any other warranty, condition or guarantee) if the total price for the Goods has not been paid by the due date for payment.

11.10 Any claim under the warranties in condition 11.2 must be made in writing and the Goods in question must be returned to Us within 6 months of the date of delivery, suitably packaged, carriage paid and accompanied by proof of purchase and details of the nature of the alleged defect. We shall be under no liability under the warranties in condition 11.2 if these conditions are not complied with.

12. LIMITATION OF LIABILITY

12.1 Subject to condition 12.3, the following provisions set out Our entire financial liability (including any liability for the acts or omissions of Our employees, agents and sub-contractors) to You in respect of:

(a) any breach of these conditions;

(b) any representation, statement or tortious act or omission including negligence arising under or in connection with the Contract.

12.2 All warranties, conditions and other terms implied by statute or common law (save for the conditions implied by section 12 of the Sale of Goods Act 1979) are, to the fullest extent permitted by law, excluded from the Contract.

12.3 Nothing in these conditions excludes or limits Our liability for death or personal injury caused by Our negligence, fraud or fraudulent misrepresentation or any other matter for which it would be unlawful for Us to exclude or restrict liability.

12.4 You are responsible for carrying out such tests and examinations as are sufficiently prudent and effective to determine that the other product sold in conjunction with or incorporating any Goods are safe and free from defects. We shall not be liable for any death, injury, loss or damage to property or any other damage, charges and/or expenses (“Loss”) arising as a result of Your sale or supply or the sale or supply by any third party of any product in conjunction with or incorporating any Goods, except to the extent that such Loss arises as a result of Our negligence or breach of its statutory obligations.

12.5 No liability can be accepted for any advice given by or for the quality of Services rendered by any of Our sub-contractors unless We have Ourselves confirmed that advice on the quality of those Services in writing.

12.6 Subject to conditions 12.2 and 12.3:

(a) Our total liability in contract, tort (including negligence or breach of statutory duty), misrepresentation, restitution or otherwise, arising in connection with the performance or contemplated performance of this Contract and in the supply of Services to You shall be limited to [the lower of £100,000 or 100% of the price of the Goods or Services]; and

(b) We shall not be liable to You, whether in contract, tort (including negligence) breach of statutory duty or otherwise, for any pure economic loss of profit, loss of business, depletion of goodwill or any indirect or consequential loss, or any claims for consequential compensation whatsoever (howsoever caused) which arise out of or in connection with the Contract.

13. FORCE MAJEURE

We reserve the right to defer the date of delivery or to cancel the Contract or reduce the volume of the Goods ordered by You (without liability to You) if We are prevented from or delayed in the carrying on of Our business due to circumstances beyond Our reasonable control of including, without limitation, acts of God, governmental actions, war or national emergency, acts of terrorism, protests, riot, civil commotion, fire, explosion, flood, epidemic, lock-outs, strikes or other labour disputes (whether or not relating to either party’s workforce), or restraints or delays affecting carriers or inability or delay in obtaining supplies of adequate or suitable materials.

14. GENERAL

14.1 Each right or remedy of Ours under the Contract is without prejudice to any other right or remedy of Ours whether under the Contract or not.

14.2 If any provision of the Contract is found by any court, tribunal or administrative body of competent jurisdiction to be wholly or partly illegal, invalid, void, voidable, unenforceable or unreasonable it shall to the extent of such illegality, invalidity, voidness, voidability, unenforceability or unreasonableness be deemed severable and the remaining provisions of the Contract and the remainder of such provision shall continue in full force and effect.

14.3 If any If any invalid, unenforceable or illegal provision of the Contract would be valid, enforceable and legal if some part of it were deleted, the provision shall apply with the minimum modification necessary to make it legal, valid and enforceable.

14.4 Failure or delay by Us in enforcing or partially enforcing any provision of the Contract will not be construed as a waiver of any of Our rights under the Contract.

14.5 A waiver of any right or remedy under the Contract is only effective if in writing and shall not be deemed to be a waiver of any subsequent breach or default. Any waiver by Us of any breach of, or any default under, any provision of the Contract by You will not be deemed a waiver of any subsequent breach or default and will in no way affect the other terms of the Contract.

14.6 The parties to this Contract do not intend that any term of this Contract will be enforceable by virtue of the Contracts (Rights of Third Parties) Act 1999 by any person that is not a party to it.

14.7 The formation, existence, construction, performance, validity and all aspects of the Contract shall be governed by English law and the parties submit to the exclusive jurisdiction of the English courts.

14.8 We may at any time assign, transfer, charge, subcontract or deal in any other manner with all or any of its rights or obligations under the Contract. You may not assign, transfer, charge, subcontract or deal in any other manner with all or any of Your rights or obligations under the Contract without Our prior written consent.

15. COMMUNICATIONS

15.1 All communications between the parties about this Contract must be in writing and delivered by hand or sent by pre-paid first class post or sent by facsimile transmission:

(a) (in case of communications to Us) to our registered office or such changed address as shall be notified to You by Us; or

(b) (in the case of the communications to You) to Your registered office (if a company) or (in any other case) to Your address set out in any document which forms part of this Contract or such other address as shall be notified to Us by You.

15.2 Communications shall be deemed to have been received:

(a) if sent by pre-paid first class post, 2 days (excluding Saturdays, Sundays and bank and public holidays) after posting (exclusive of the day of posting);

(b) if delivered by hand, on the day of delivery;

(c) if sent by facsimile transmission on a working day prior to 4.00 pm, at the time of transmission and otherwise on the next working day.

15.3 Communications addressed to Us shall be marked for the attention of the Managing Director.

15.4 The provisions of this clause shall not apply to the service of any proceedings or other documents in any legal action.

Page 67: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Statement of QUALITY ASSURANCE

Hawco Ltd operates a Quality System which has been certified by BSI Quality Assurance to BS EN ISO 9001:2008

Packing, Postage/Delivery charges and VAT where applicable are extra. Our standard terms and conditions of sale/purchase apply. TERMS: Payment to be made within (30) days of the date of the invoice. Claims in respect of this invoice or the goods enumerated thereon must be made within 2 working days of receipt. Claims for damage must be made within 24hrs of receipt. No goods may be returned without prior consent in writing. A Returns Number will be issued from the despatch address highlighted at the bottom of our despatch note.

Goods remain the property of Hawco Ltd until full payment is received.

Page 68: Price List 2014 sale by empowering staff to make key decisions face to face with customers. Hawco Conditions Capacity conditions Unit cooling and heating capacities shown within this

Field Sales ContactsHead of Contractor Sales 07919 414182

North07774 688528

Midlands07831 318430

South07831 612777

[email protected] www.hawco.co.uk