preventive maintenance manualagilfence.com/uploads/resources/563896997.pdf · 15/03/13/rev1/...
TRANSCRIPT
15/03/13/Rev1/ Preventive Maintenance Manual 1
Preventive Maintenance Manual
15/03/13/Rev1/ Preventive Maintenance Manual 2
The information contained herein contains proprietary information of ST Electronics
(Satcom & Sensor Systems) Pte Ltd and may not be copied, used or disclosed in whole
or in part to any third party except with written approval of ST Electronics (Satcom &
Sensor Systems) or if it has been authorised under a contract.
15/03/13/Rev1/ Preventive Maintenance Manual 3
1 Introduction 4
2 Quarterly 5
2.1 Task & Procedure 6
3 Biannually 7
4 Annually 8
4.1 Task & Procedure 9
5 Biennially 10
5.1 Task & Procedure 11
6 Triennially 12
6.1 Task & Procedure 13
7 As Needed 14
7.1 Task & Procedure 15
15/03/13/Rev1/ Preventive Maintenance Manual 4
The program presented in this manual represents the minimum requirements for AgilFence PIDS and its peripheral devices. However, more frequent service may be warranted in specific sites which require more care. The purpose of this maintenance program is to promote repair consistency and cost efficiency, and assure that the system is in good operating condition. ST Electronics (Satcom & Sensor Systems) is the manufacturer of AgilFence PIDS, the PIDS system described in this manual and as such is responsible for the system safety, reliability and performance only if:
1. installation 2. calibration & recalibration 3. changes and repair
have been carried out by authorised personnel and if the system equipment is used according to the instructions provided and operation is only entrusted to qualified, trained personnel. ST Electronics (Satcom & Sensor Systems) is not liable to any damages derived from the non-compliance with the aforementioned recommendations. This document provides a recommended schedule of preventive maintenance categorised according to their frequency:
- Quarterly - Biannually - Annually - Biennially - Triennially - As needed
1 . INTRODUCTION
15/03/13/Rev1/ Preventive Maintenance Manual 5
Task Description Note
PTZ Camera Cleaning the outer body of the camera.
Clearing of lizard/bird waste.
Clean the internal of the cover.
Clear all the waste and dirt.
.
Refer to 2.1 for task and procedure.
Outdoor UPS System Cleaning the outer body of the enclosure.
Clear all the waste and dirt inside the compartment.
Measure the voltage of the backup battery.
Check all the connectors are attached to the device.
Check for loose mounting.
Check all devices are working and
powered up.
Fixed Camera Housing Cleaning of Camera Housing.
Clear lizard eggs/shit of the internal
Refer to 2.1 for
2. Quarterly
15/03/13/Rev1/ Preventive Maintenance Manual 6
Task Description Note
housing if any. task and procedure.
Thermal Camera Cleaning the body of the camera.
Cleaning the lens of the camera.
Refer to 2.1 for
task and procedure.
15/03/13/Rev1/ Preventive Maintenance Manual 7
Task Description Note
Cleaning PTZ Camera Inform OCC on which camera we are doing the servicing.
Lower the PTZ camera.
Clear all the waste and dirt.
Clean the internal of the perspex cover.
Fix back the cover. Ensure they are tightened properly.
Clean the outer of the cover.
After finish servicing, inform OCC.
Lower the camera pole, gently.
When cleaning the perspex cover, use a clean cloth.
Secure the collapsible pole tightly.
Cleaning Fixed Camera Housing
Inform OCC on which camera we are doing the servicing.
Lower the camera.
Clear all the waste and dirt inside the housing.
Clean up the glass panel of the camera housing.
After finish servicing, inform OCC.
Lower the camera pole, gently.
Secure the collapsible pole tightly after servicing.
Thermal Camera Inform OCC before doing the servicing.
Lower the camera
2 1 Task & Procedure
15/03/13/Rev1/ Preventive Maintenance Manual 8
Task Description Note
Lower the camera.
Clean the body of the camera
Cleaning the lens of the camera
After finish servicing, inform OCC
pole, gently.
Secure the collapsible pole tightly after servicing.
15/03/13/Rev1/ Preventive Maintenance Manual 9
Task Description Note
Server Rack in AOC Room
Clean and dust inside and outside of the rack.
Check the KVM is working.
Check PIDs server is working.
Check the UPS system is working
The replace battery LED is not lighted up.
Replace the back battery if indicator light up.
Check there is not beeping at the UPS.
Beeping indicate Low Battery Warning Level.
Ensure all connectors are secure.
Check the status of each PIDs sensor through AgilFence Signal Processing Unit software, if pre-tension value is below threshold, perform pre-tension activity.
Refer to 7.1 for task and procedure.
Refer to 4.1. for task and procedure.
NVR System Clean and dust inside and outside of the rack.
Check all the equipment in the rack are working.
3. Biannually
15/03/13/Rev1/ Preventive Maintenance Manual 10
Task Description Note
Check all the connectors are connected.
Check all the used ports of the network switches communicating LED lights are blinking.
Check all the CCTV images.
Test out the Pan/Tilt/Zoom of all the PTZ cameras.
Check the recording of the NVR.
Record the earliest recording date.
15/03/13/Rev1/ Preventive Maintenance Manual 11
Task Description Note
Fibre Optic Sensor Cable and GI conduit at Fencing
Check the sensor cable is attached with cable ties.
Replace new cable ties if there is breakage.
Outer jacket of the sensor is not injured.
Replace new sensor cable if the outer jacket is damaged.
Metal Containment GI conduit pipe, coupling (socket) and space bar saddle is not rust.
Paint it if they are rusty.
The conduit pipe is fastening with space bar saddle, and the leave of the saddle is not loose.
Tighten the screw if loose.
Replace new screws if missing.
Splicing Enclosure Box Enclosure box is not loose and shaky.
Tighten the box if it is loose.
The box cover is not damaged.
Replace a new cover if it is damaged.
Internal of the box are clean. Does
4. Annually
15/03/13/Rev1/ Preventive Maintenance Manual 12
Task Description Note
not have any ants or lizard eggs/shits
Clean or brush away all the wastes.
15/03/13/Rev1/ Preventive Maintenance Manual 13
Task Description Note
Pre-Tensioning of sensor cable
Inform OCC on which cluster, channel and sensor that is working on.
Pre-tensioning is perform using bragg meter.
Inform OCC on completion.
At AOC, check the status through AgilFence Signal Processing Unit to confirm the affected sensor cable is back to it threshold value.
4 1 Task & Procedure
15/03/13/Rev1/ Preventive Maintenance Manual 14
Task Description Note
Outdoor UPS Replace of backup battery
Refer to 5.1 for task and procedure.
5. Biennially
15/03/13/Rev1/ Preventive Maintenance Manual 15
Task Description Note
Replace backup battery at Outdoor UPS
Inform OCC on replacing which UPS battery.
Switch off the circuit breaker.
Replace new backup battery.
Write a label over the new battery on date of replacement.
Inform OCC on completion of the replacement.
Do not allow the battery terminal in contact with metal body.
Secure the terminal tightly.
5 1 Task & Procedure
15/03/13/Rev1/ Preventive Maintenance Manual 16
Task Description Note
Solar Obstruction Light Replace of internal battery
Refer to 6a. for task and procedure.
6. Triennially
15/03/13/Rev1/ Preventive Maintenance Manual 17
Task Description Note
Replace Solar Obstruction light internal battery
Inform OCC before replacing the internal battery.
Lower the collapsible pole.
Dismantle the Solar light.
Replace the new battery.
Re-install Solar light.
After finish servicing, inform OCC.
Lower the camera pole, gently.
Secure the collapsible pole tightly after servicing.
6 1 Task & Procedure
15/03/13/Rev1/ Preventive Maintenance Manual 18
Task Description Note
Outdoor UPS Replace faulty UPS System
Refer to 7.1. for Task And Procedure.
UPS/ back battery in Server Rack.
Replace faulty UPS System
Refer to 7.1 for Task and Procedure.
Equipment at Server Rack
Replace faulty equipment in the rack
Refer to 7.1 for Task And Procedure.
Solar Obstruction Light Replace faulty set
Refer to 7.1 for Task and Procedure.
7. As Needed
15/03/13/Rev1/ Preventive Maintenance Manual 19
Task Description Note
Outdoor UPS Inform OCC before replacing the faulty UPS system.
Switch off the circuit breaker.
Replace the new UPS System.
Switch on the circuit breaker.
Inform OCC on completion of the replacement.
UPS/backup battery in Server Rack
Inform OCC before replacing the UPS System.
Shut down and switch off all the server and equipment that is using the UPS system.
Replace the new UPS System.
Plug back all equipment that is using the UPS System.
Power up the UPS system.
Power up all the equipment/ server.
Inform OCC on completion.
Equipment at Server Rack
Inform OCC before replacing the faulty equipment.
Switch off the faulty equipment.
7 1 Task & Procedure
15/03/13/Rev1/ Preventive Maintenance Manual 20
Task Description Note
Replace with a new one.
Inform OC on completion.
Solar Obstruction Light Inform OCC before replacing the faulty set.
Lower the collapsible pole.
Dismantle the faulty set.
Replace and install the new one.
Inform OCC on completion of the replacement.
Lower the camera pole, gently.
Secure the collapsible pole tightly after servicing.
15/03/13/Rev1/ Preventive Maintenance Manual 21
ST Electronics ( Satcom & Sensor Systems ) Pte Ltd 1 Ang Mo Kio Electronics Park Road, #06‐02, ST Engineering Hub, Singapore 567710 T: (65) 6521 7888 F: 6521 7801 www.agilfence.com Regn.: 199103901W