preventa safety modules - rs components
TRANSCRIPT
1/0 Te
1
Preventa safety modulesSelection guide
Applications
Modules
Conforming tostandards
Machineassemblies
Principlesfor design
Number of circuitsSafety
Signalling
DisplaySupply voltage
Synchronisation timebetween inputs
Input channel voltage24 V/48 V version
115 V/230 V version
References
Module type
For Emergency stop and limit switch monitoring
IEC 204-1, EN 292, EN 418, IEC 204-1, EN 292, EN 418,EN 60204-1 EN 60204-1
EN 954-1 - category 3 EN 954-1 - category 4EN 1088 (instantaneous contacts)
EN 954-1 - category 3(time delay contacts)EN 1088
2 N/O 3 N/O 3 N/O instantaneous contacts+ 2 N/O time delay contacts
– 1 N/C 1 N/C
2 LEDs 2 LEDs 4 LEDsc and a 24 V c and a 24 V c and a 24 Vc 115 V c 115 Vc 230 V c 230 V
– – 75 ms (automatic starting)
c and a 24 V/– c and a 24 V/– a 24 V/–
c 115 V/230 V – a 48 V/48 V
XPS-AL5110 c and a 24 V XPS-AX5120 c and a 24 V XPS-AT5110 c and a 24 VXPS-AL3410 c 115 V XPS-AT3410 c 115 VXPS-AL3710 c 230 V XPS-AT3710 c 230 V
XPS-AL - page 1/14 XPS-AX - page 1/14 XPS-AT - page 1/14
t
1/1Te
1
For Emergency stop, limit switch and two-hand control monitoring
IEC 204-1, EN 292, EN 418,EN 60204-1
EN 954-1 - category 4EN 1088EN 574111A
2 N/O 3 N/O 6 N/O
– 1 N/C 1 N/C
4 LEDs 4 LEDs 4 LEDsc and a 24 V c and a 24 V c and a 24 Vc and a 48 V c and a 48 V c and a 48 Vc 115 V c 115 V c 115 Vc 230 V c 230 V c 230 V
300 ms (automatic starting)
a 24 V/48 V
a 48 V/48 V
XPS-AS5140 c and a 24 V XPS-AM5140 c and a 24 V XPS-AP5140 c and a 24 VXPS-AS5340 c and a 48 V XPS-AM5340 c and a 48 V XPS-AP5340 c and a 48 VXPS-AS3440 c 115 V XPS-AM3440 c 115 V XPS-AP3440 c 115 VXPS-AS3740 c 230 V XPS-AM3740 c 230 V XPS-AP3740 c 230 V
XPS-AS - page 1/19 XPS-AM - page 1/19 XPS-AP - page 1/19
1/2 Te
1
Preventa safety modulesSelection guide (continued)
Applications
Modules
Conforming tostandards
Machineassemblies
Principlesfor design
Number of circuitsSafety
Signalling
DisplaySupply voltage
Synchronisation timebetween inputs
Input channel voltage24 V/48 V version
115 V/230 V version
References
Module type
For Emergency stop, limit switch, two-hand control, safety mat and edge monitoring
IEC 204-1, EN 292, EN 418,EN 60204-1
EN 954-1 - category 4EN 1088EN 574 type III A
2 N/O 3 N/O
2 solid state for signalling to PLC 1 N/C + 2 solid state for signalling to PLC
4 LEDs 4 LEDsc and a 24 V c and a 24 Vc and a 48 V c and a 48 Vc 115 V c 115 Vc 230 V c 230 V
300 ms (automatic starting) 300 ms (automatic starting)
a 24 V/48 V a 24 V/48 V
a 48 V/48 V a 48 V/48 V
XPS-ASF5142 c and a 24 V XPS-AMF5142 c and a 24 VXPS-ASF5342 c and a 48 V XPS-AMF5342 c and a 48 VXPS-ASF3442 c 115 V XPS-AMF3442 c 115 VXPS-ASF3742 c 230 V XPS-AMF3742 c 230 V
XPS-ASF - page 1/25 XPS-AMF - page 1/25
1/3Te
1
For Emergency stop, limit switch, two-hand For increasing the number of safety contactscontrol, safety mat and edge monitoring
IEC 204-1, EN 292, EN 418, IEC 204-1, EN 292, EN 418,EN 60204-1, EN 1760 EN 60204-1
EN 954-1 - category 4 EN 954-1 - category 4EN 1088EN 574111A
6 N/O 4 N/O 8 N/O
1 N/C + 2 solid state for signalling to PLC 1 N/C + 1 solid state for signalling to PLC 1 N/C + 1 solid state for signalling to PLC
4 LEDs 3 LEDs 3 LEDsc and a 24 V c and a 24 V c and a 24 Vc and a 48 V c 115 V c 115 Vc 115 V c 230 V c 230 Vc 230 V
300 ms (automatic starting) – –
a 24 V/48 V a 24 V a 24 V
a 48 V/48 V a 24 V/24 V a 24 V/24 V
XPS-APF5142 c and a 24 V XPS-ECM5131 c and a 24 V XPS-ECP5131 c and a 24 VXPS-APF5342 c and a 48 V XPS-ECM3431 c 115 V XPS-ECP3431 c 115 VXPS-APF3442 c 115 V XPS-ECM3731 c 230 V XPS-ECP3731 c 230 VXPS-APF3742 c 230 V
XPS-APF - page 1/25 XPS-ECM - page 1/33 XPS-ECP - page 1/33
1/4 Te
1
Preventa safety modulesSelection guide (continued)
For electrical monitoring of limit switches For electrical monitoring of two-handcombined in pairs control stations
IEC 204-1, EN 292, IEC 204-1, EN 292,EN 60204-1 EN 60204-1
EN 954-1 - category 4 DIN 24980, NF E 09-034 and 035EN 1088 EN 954-1 - category 4
EN 574 type III C
3 N/O 2 N/O
1 N/C + 2 solid state for signalling to PLC 1 N/C
3 LEDs 3 LEDsc and a 24 V a 24 Vc and a 48 V c 24 Vc 115 V c 115 Vc 230 V c 230 V
1.5 s 500 ms
a 24 V/48 V a 24 V (a 24 V), a 48 V (c 24 V)
a 48 V/48 V a 48 V/48 V
XPS-FB5111 c and a 24 V XPS-BC1110 a 24 VXPS-FB5311 c and a 48 V XPS-BC3110 c 24 VXPS-FB3411 c 115 V XPS-BC3410 c 115 VXPS-FB3711 c 230 V XPS-BC3710 c 230 V
XPS-FB- page 1/38 XPS-BC - page 1/41
Applications
Modules
Conforming tostandards
Machineassemblies
Principlesfor design
Number of circuitsSafety
Signalling
DisplaySupply voltage
Synchronisation timebetween inputs
Input channel voltage24 V/48 V version
115 V/230 V version
References
Module type
1/5Te
1
For cyclic monitoring of 1 to 4 For zero speed detection of a.c. or For monitoring overtravel on linearsingle beam, infra-red, security light d.c. motors pressesbarrier detectors type XU2-S, withtest input
Guarding access points to Detecting stop condition of motor Automatically monitors the slowpotentially hazardous zones by measuring the remanent voltage down distance of linear presses(association of safety module + in the stator windings (compatible (for example : hydraulic, pneumatic1 to 4 single beam, infra-red, with electronic motor control or screw presses)security light barrier detectors devices such as variable speedtype XU2-S) drives, d.c. injection brakes, etc.)
IEC 204-1, EN 292, IEC 204-1, EN 292, EN 692, IEC 204-1, EN 292, EN 693,EN 60204-1 EN 60204-1 EN 60204-1
EN 61496-1 - type 2 EN 954-1 - category 3 EN 954-1 - category 4Certification only valid when used EN 1088with XU2-S safety light barrierdetectors
2 N/O 1 N/O + 1 N/C 3 N/O
1 solid state output 2 solid state outputsfor signalling to PLC for signalling to PLC 1 N/C
4 LEDs 2 LEDs 8 LEDsc and a 24 V a 24 V c and a 24 V
c 115 V c 120 Vc 230 V c 230 V
PNP version : XPS-VN1142 a 24 V GNK-L24VACDC c and a 24 VXPS-CEP5141 c and a 24 V XPS-VN3442 c 115 V GNK-L120VAC c 120 VNPN version : XPS-VN3742 c 230 V GNK-L230VAC c 230 VXPS-CEN5141 c and a 24 V
XPS-CE - page 1/46 XPS-VN - page 1/53 GNK-L - page 1/60
Applications
Modules
Functions
Conforming tostandards
Machineassemblies
Principlesfor design
Number of circuitsSafety
Signalling
DisplaySupply voltage
References
Module type
0
Available October '98
1/6 Te
1
Preventa safety modulesSelection guide (continued)
Applications
Modules
Functions
Conforming tostandards
Machineassemblies
Principlesfor design
Number of circuitsSafety
Signalling
DisplaySupply voltage
References
Module type
For dynamic monitoring of solenoid valveson linear hydraulic presses
Dynamic monitoring of the position of the gate valvepistons in a hydraulic safety circuit on linear presses.Dangerous movements of the machine are allowed whenthe correct change of signal occurs
IEC 204-1, EN 292, EN 693,EN 60204-1
EN 954-1 - category 4
2 N/O + 1 N/C
–
8 LEDsa 24 V
XPS-PVT1180 a 24 V
XPS-PVT - page 1/63
For dynamic monitoring of double-bodiedsolenoid valves
Dynamic monitoring of double-bodied safety solenoidvalves on eccentric presses. The device prevents en-gagement of the clutch and engages the brake if a faultoccurs in the solenoid
IEC 204-1, EN 292, EN 692,EN 60204-1
EN 954-1 - category 4
1 N/O + 1 N/C
4 solid state outputs for signalling to PLC
8 LEDsa 24 Vc 120 Vc 230 V
XPS-PVK1184 a 24 VXPS-PVK3484 c 115 VXPS-PVK3784 c 230 V
XPS-PVK - page 1/67
1/7Te
1
For safety stop with automatic overtravel monitoring and control of eccentricpresses
Automatically monitors the stopping distance for each cycle + maintain openfunction, for eccentric presses
IEC 204-1, EN 292, EN 692,EN 60204-1
EN 954-1 - category 4
3 N/O
4 solid state for signalling to PLC
4 LEDs–c 120 Vc 230 V
XPS-OT3444 c 115 VXPS-OT3744 c 230 V
XPS-OT - page 1/72
For applications with safety amplifier relay used in conjunction with one or twoproximity sensors or limit switches
Error-free detection and amplification of limit switch signals, signals from PNPor NPN type proximity sensors (a 24 V), or a 2-wire type connection with“-” and “+” switching. Conversion to contact signals for self-monitoring safetymodules
IEC 204-1, EN 292,EN 60204-1
Can be used in systems up to category 4(EN 954-1)
2 N/O + 2 N/C
1 N/C
4 LEDs–c 120 Vc 230 V
XPS-NS3440 c 115 VXPS-NS3740 c 230 V
XPS-NS - page 1/75