prestige - pex universe · 2018-06-04 · prestige performance specifications boiler model fuel...
TRANSCRIPT
Featuring ACVMax Control with:
l 439StainlessSteelFireTubeHeatExchangerl ASMEStampedHeatExchangerl 95%AFUEl Turndownratiosupto5.5:1l LowPressureDropwithProvenPerformancel 2”to4”Ventingl MultipleVentingTerminationOptionsl LowNOx-2012SCAQMDCertifiedl 7Modelsfrom80to399MBHl 2YearControl&BlowerWarrantyl 10YearLimitedHeatExchangerWarrantyl 5&10YearExtendedWarrantyOptions
High Efficiency Condensing Gas Boilers
l 60SecondSet-upBasedonFormerTriMaxPlatforml IntegratedCascadeFunctionforupto6Boilersl TwoResetCurves/SetPointsl MultipleZoneControll MultipleCirculatorControl
Prestige
Prestige - Leader in Ser viceabi l i ty
ACV-Max Control
60 Second Set-Up• Choosefrom6standardheatingapplicationsto setuptheboilerin60secondsorless. •FinnedTubeBaseboard •HighMassRadiant •CastIronBaseboard •LowMassRadiant •Radiators •Fancoil• Preconfiguredforindirecthotwaterapplications
Integrated CascadeJoinsupto6boilers:Masterboilerautomaticallyrecognizeslinkedboilers:MeetssimultaneousDHW&SpaceHeatingcalls:FullParallelModulation:AutomaticDutyCycling.
Multiple Zone Control• Accepts2spaceheatingcallswithindependentoutdoorresetcurves• Simultaneouslyheatdualtemperatureheatingsystemswithbuilt-inmixingvalvecontrol• Manageupto2spaceheatingzonesand1DHWzonewithoutanexternalzonecontrolpanel
Multiple Circulator Control• Presetsallowquickconfigurationof4circulatoroutputsfortheapplication• Eachcirculatoroutputisfullyconfigurableforcustomapplications
Intelligent TroubleshootingDescribeslockoutsinplainenglishandsuggestssolutions:Storeslast8errors.Recordssensorreadingsfor24hours.
Next Generation Fire Tube Heat ExchangerHigh Water Content •Providesstabletemperaturecontrol •Lowsensitivitytowaterflow •Reducesshortcycling •Adaptstolargeorsmallheatingloads
Unique Geometry •Designedformaximumreliabilitywithlowthermalstress •Improvedwaterflowformaximumheattransfer •439StainlessSteelwithtitaniumforcorrosionresistance •Polypropylenecondensatepanandflueresistscorrosion
Reliable Low Maintenance Design •Selfcleaningdesignwashesawaycombustiondebris •12yearhistoryofreliableperformance •Highperformanceburnerdesign •Lowpressuredropallowspipingdirectlytothesystem •ASMEStamped
Prestige - Leader in Contractor Fr iendly Features
Prestige Solo
Polypropylene Flue and Condensate PanEliminates corrosion from condensate
Test Ports in both Flue and Air Connections
Integrated Check Valve - To eliminateflue gas blow back in negative pressure locations
Offset Blower with quickconnect to minimize heatload and ease maintenance
Sound AttentuatedAir Inlet
ACVMax Display Module
Industry LeadingFire tube heatexchanger
Cast Aluminum burner plate withintegrated angled sight glass
Single piece gasket and insulation to reduceparts & ease maintenance
Swing Out Electrical Panel Permits quick access to boiler internals
The Widest Range of Venting and Termination Options
Venting-2”,3”,and4”diametersdependingonmodel-PVC,CPVC,SSandPolypropylenematerials-FlexiblePolypropyleneforchimneychases
-Concentric(399only)ortwinpipe-Extendedventlengthsupto100feet
-CommonVentformultipleboilers(399only)
Terminations-TraditionalPVC/CPVC/PP/SSpipingelbows
-Flush-mountPVCfortwinpipes-Flush-mountStainlessSteelfortwinpipes
-SingleholeConcentricTerminationfortwinpipes-HorizontalConcentricTermination(399only)
-HorizontalandVerticalCommonVentTerminations(399only)
p f
Blackwood NJ 08012One Triangle LaneTriangle Tube www.triangletube.com
856.228.3584856.228.8881
PrestigePerformance Specifications
Boiler Model Fuel
Input Modulation
MBHAFUE
DOEHeating Capacity
MBH
TurndownRatio
Net AHRIRating MBH
Water Volume
Gal.
Boiler Model
Supply/ReturnConnections
GasConnections
Vent/AirDiameter
DimensionsD x W x H
WeightLbs
95.1%* 7.4Solo 399 NaturalPropane
72.5 to 399 379,000 330,0005.5 : 1
4.5
Solo 299 NaturalPropane
72.5 to 299 272,000 237,00095% 7.4
Solo 250 NaturalPropane
43.6 to 240 218,000 190,00095% 5.5 : 1
4.1 : 1
4
Solo 175 NaturalPropane
30.9 to 170 154,000 134,00095% 5.3
Solo 155 NaturalPropane
27.8 to 153 138,000 120,00095% 5.5 : 1
5.5 : 1
2.1
Solo 110 NaturalPropane
20 to 110 99,000 86,00095% 2.1
Solo 80 NaturalPropane
16 to 80 72,000 63,00095% 5.0 : 1
5.5 : 1
103
Solo 110 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16" 103
Solo 80 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16"
118
Solo 175 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16" 128
Solo 155 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"
140
Solo 299 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8" 210
Solo 250 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"
216Solo 399 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8"
Connections/Dimensions/DataBoiler Model Fuel
Input Modulation
MBHAFUE
DOEHeating Capacity
MBH
TurndownRatio
Net AHRIRating MBH
Water Volume
Gal.
Boiler Model
Supply/ReturnConnections
GasConnections
Vent/AirDiameter
DimensionsD x W x H
WeightLbs
95.1%* 7.4Solo 399 NaturalPropane
72.5 to 399 379,000 330,0005.5 : 1
4.5
Solo 299 NaturalPropane
72.5 to 299 272,000 237,00095% 7.4
Solo 250 NaturalPropane
43.6 to 240 218,000 190,00095% 5.5 : 1
4.1 : 1
4
Solo 175 NaturalPropane
30.9 to 170 154,000 134,00095% 5.3
Solo 155 NaturalPropane
27.8 to 153 138,000 120,00095% 5.5 : 1
5.5 : 1
2.1
Solo 110 NaturalPropane
20 to 110 99,000 86,00095% 2.1
Solo 80 NaturalPropane
16 to 80 72,000 63,00095% 5.0 : 1
5.5 : 1
103
Solo 110 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16" 103
Solo 80 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16"
118
Solo 175 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16" 128
Solo 155 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"
140
Solo 299 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8" 210
Solo 250 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"
216Solo 399 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8"
Couple to Industry Leading Indirect Water Heater FamilyTank in Tank Design (No Coils – Maintenance Free)
l Unparalleledperformanceallows25-50%smallersizethancompetitorsl Fastestrecovery-recoveryin30%-40%lesstimethancompetitorsl StainlessSteelconstructionl ResidentialSmarttankshavelimitedlifetimewarrantyl ComfortTankshave10yearlimitedwarrantyl 7sizesinSmartfamilyl 2sizesinComfortfamily
Triangle Tube reserves the right to make product changes or improvements at any time without notice.
*Thermal Efficiency
2015
-15
Pre
stig
e S
olo
AC
VM
ax L
itera
ture
- 1
2/15
/15