presentation on applications of network management using uhf - microwave links. paper presented by:...
TRANSCRIPT
Presentation on Presentation on Applications of Network Applications of Network
ManagementManagementUsing UHF - Microwave Using UHF - Microwave
Links.Links.
Paper Presented By:Paper Presented By:
Sunil V.VyasSunil V.VyasDigital Integrator Pvt. Ltd., India.Digital Integrator Pvt. Ltd., India.
[email protected] & [email protected]@sancharnet.in & [email protected]
Application of Network Application of Network Management Management
We are managing a Network of Indian We are managing a Network of Indian Railways ( Microwave Repeater Railways ( Microwave Repeater Station ) which is a main source of Station ) which is a main source of Communication media for Indian Communication media for Indian Railways.Railways.
What We have a Number of Divisions What We have a Number of Divisions in the Regional Railways e.g.. Western in the Regional Railways e.g.. Western Railways, and these Divisions are Railways, and these Divisions are having divisional HQ. having divisional HQ.
Cont.….Cont.….
NMSNMS
These divisional Head These divisional Head Quarters are looking after the Quarters are looking after the
administration of Railways administration of Railways Traffic in the division. All Traffic in the division. All
divisions are almost having divisions are almost having Railway Track of almost 200 Railway Track of almost 200
to 250 kms. Consisting 5 to 7 to 250 kms. Consisting 5 to 7 Repeaters of Microwave Repeaters of Microwave Network in the division.Network in the division.The mainpurpose of These The mainpurpose of These
repeater is to boost the signal and repeater is to boost the signal and continue the communication link continue the communication link
for smooth working in the division.for smooth working in the division.
NMS by DIPl, Indore IndiaNMS by DIPl, Indore India
Every Repeater Station is isolated by almost 55 Every Repeater Station is isolated by almost 55 to 60 kms. Distance ,this depends upon the to 60 kms. Distance ,this depends upon the terrain of the region.terrain of the region.
There are many equipment housed at these There are many equipment housed at these stations in order to make communication stations in order to make communication workable, like Transmitters (2 nos.) , workable, like Transmitters (2 nos.) , Receivers( 02), +24 V Power Supply , stand by Receivers( 02), +24 V Power Supply , stand by supply (secondary) using Battery Bank, Stand supply (secondary) using Battery Bank, Stand by Battery Bank, D/ Generator set, Battery by Battery Bank, D/ Generator set, Battery Charger, Float, SPV Supply , Air conditioner Set Charger, Float, SPV Supply , Air conditioner Set etc.etc.
NMS by DIPL, Indore.NMS by DIPL, Indore. India.India.
These Transmitters and Receivers are having many important Analog and Digital These Transmitters and Receivers are having many important Analog and Digital signals. These Signals are presently monitored Manually , i.e.. 24 hrs . Man Power is signals. These Signals are presently monitored Manually , i.e.. 24 hrs . Man Power is provided at all these locations. But efficiency and duty attendance is poor. In order to provided at all these locations. But efficiency and duty attendance is poor. In order to get better efficiency ;we have devised a system called NMS for MW . get better efficiency ;we have devised a system called NMS for MW .
Almost 100 + Analog and 56 + Digital Important Signals are required to be monitored Almost 100 + Analog and 56 + Digital Important Signals are required to be monitored and some to the extent of 16 Digital Out Signals for controlling devices like and some to the extent of 16 Digital Out Signals for controlling devices like
Switching of Transmitter, Switching of Transmitter, Switching of Receivers,Switching of Receivers, Switching of Battery Bank from Load to Charger and Charger to Switching of Battery Bank from Load to Charger and Charger to
Load in secured way . Load in secured way . Switching On/ off Diesel Generator Set Switching On/ off Diesel Generator Set Switching On/ Off SPV supply .Switching On/ Off SPV supply . Monitoring of Room Temp & Switching Air conditioner.Monitoring of Room Temp & Switching Air conditioner. And On top of this all Remotely sitting at the Divisional Railways And On top of this all Remotely sitting at the Divisional Railways
HQ. HQ.
NMS by DIPL, Indore. IndiaNMS by DIPL, Indore. India
One can do it using system developed by us.One can do it using system developed by us. We have Developed following components We have Developed following components Data Loggers stationed at all the stations for Data Data Loggers stationed at all the stations for Data
acquisition of the signals of local station.Compatible acquisition of the signals of local station.Compatible to requirement of nos. of Analog and Digital Signals.to requirement of nos. of Analog and Digital Signals.
These Data Loggers are connected to each other in These Data Loggers are connected to each other in daisy chaining /Multi drop Network topology and daisy chaining /Multi drop Network topology and finally to FEP Front End Processor and then To FAS finally to FEP Front End Processor and then To FAS Front Analyzer System through Memory Buffer. Front Analyzer System through Memory Buffer. Application software and Truth / Lookup tables are Application software and Truth / Lookup tables are residing in FIFO memory Buffer.residing in FIFO memory Buffer.
NMS by DIPL, Indore INDIANMS by DIPL, Indore INDIA
#1 Rep. Stn #2 stn
NMS by DIPL, Indore. IndiaNMS by DIPL, Indore. India
Data Logger Data Logger
LDC Display 16 X 2
NMS, by DIPL, Indore. IndiaNMS, by DIPL, Indore. India
Strategy of connectivity of NetworkStrategy of connectivity of Network
FEP
FAS
Mem.BufMem.Buf
#1Dl #2Dl #nDl
NMS by DIPL, Indore. IndiaNMS by DIPL, Indore. India
Connectivity of NetworkConnectivity of Network All the Data Loggers are connected to Radio All the Data Loggers are connected to Radio
link of Microwave through Modem which is link of Microwave through Modem which is addressable.addressable.
FEP is connected to Memory Buffer and keep FEP is connected to Memory Buffer and keep acquiring data from Buffer.acquiring data from Buffer.
Memory Buffer is in continuos poling mode and Memory Buffer is in continuos poling mode and keep acquiring data from all the data loggers .keep acquiring data from all the data loggers .
FAS is connected to FEP and can remotely FAS is connected to FEP and can remotely access and control the activity of the system.access and control the activity of the system.
NMS by DIPL, Indore. IndiaNMS by DIPL, Indore. India
Thanks to ICTP and Mr.. S.M. Radicilla, Thanks to ICTP and Mr.. S.M. Radicilla, Mr. R. Struzack for giving me this Mr. R. Struzack for giving me this opportunity.opportunity.
Thank to Viewers for patient listeningThank to Viewers for patient listening Thanks to Mr. Carlo Fonda for all his Thanks to Mr. Carlo Fonda for all his
support.support. Sunil Vyas. Sunil Vyas.
[email protected]@hotmail.com [email protected]@sancharnet.in