presentation metal detector

27
102 Tramp Metal Detector – Oretronic III Theory Of Operation

Upload: fernando-garcia-gonzalez

Post on 15-Nov-2015

316 views

Category:

Documents


16 download

DESCRIPTION

Presentación metal detector

TRANSCRIPT

  • 102

    Tramp Metal Detector Oretronic III

    Theory Of Operation

  • 103

    Detector de Metal

    El Detector de Metal Activa un Rele de alarma ,el cual tipicamente es usado para detener la Correa y remover el Contaminante

    Se usa antes de un proceso de Clasificacin con Arneros, Chancado o cualquier otro lugar donde un contaminante Metalico, puede producir un Dao

  • 104

    Principio: El campo

    electromagnetico estcontinuamenteoscilando.Cuando un contaminanteconductivo pasa sobrela Bobina ,la oscilacin cambia esta es detectada porrla electrnica y unaalarma es activada.

    Sistema Tipo Inductancia

  • 105

    Sistema Tipo Inductancia

    Ventajas:

    1. El sistema Inductivo es mas sensible que el Sistema Eddy Current.

    Desventajas:

    1. El Contaminante debe ser mas conductivo que el Material Transportdo.

    2. Si el material es conductivo ,produce falsas paradas.

    3. El Agua es un conductor y produce falsas paradas.

    4. La sensibilidad variar de acuerdo a la separacin de las Bobinas

    5. Minerales no conductivos como el manganeso no serandetectados.

  • 106

    Sistema Tipo Eddy Current

    Principio:La Bobina Transmisora ,enva un pulso de energia.Esta energia es absorbida por el Material.

    Despues que el pulso para, el material iradia la energiaabsorvida como una corriente Eddy.

    El volumen de energia y su razon de decrecimiento es la firma de el material , su huella digital, siendo estemineral o contaminante. La electronica puede dicernirentre Mineral y Contaminante..

  • 107

    Campo Eddy Current

  • 108

    Campo primario

  • 109

    Campo Secundario

  • 110

    Field Decay Characteristics

  • 111

    Eddy Current Type System

    Advantages: Completely ignores water. Can find non-ferrous metals such as manganese. Dual coil arrangement is not sensitive to the tramp metal

    location in the material burden.

  • 112

    Eddy Current Type System

    Disadvantages:

    Dual coil arrangement is subject to material hitting the upper coil on high tonnage applications.

  • 113

    Ramsey Oretronic III

    The frame assembly is constructed of fiberglass and plastic to eliminate problems associated with wood

    The swing arm is cantilevered to better assist the transmitter coil to swing out of the way

    Spring loaded shock absorbers provide a positive cushion against shock

  • 114

    Shock Absorber and High Pile Detector

  • 115

    Ramsey Oretronic III

    The coil assemblies are constructed of PVC plastic and use a potting compound to eliminate moisture problems

    The single coil unit has both the transmitter and receiver coils contained in one coil assembly

  • 116

    Ramsey Oretronic IIISingle Coil Unit

  • 117

    Ramsey Oretronic IIISingle Coil Unit

  • 118

    Dual Coil Unit Prior to Potting

  • 119

    Single Coil Unit Prior to Potting

  • 120

    Ramsey Oretronic III

    The control enclosure is standard as NEMA 4X The keyboard is external to the enclosure and can be password protected The keypad is capacitive touch and resistant to all environments The control is at UL for listing

  • 121

    Ramsey Oretronic IIIFeatures and Benefits

    Ramsey Oretronic III is available in both a single and dual coil configuration. New and improved frame assembly and coil bonding procedure greatly reduce

    moisture problems. Cantilevered swing arm allows easy swing-out. The Oretronic control unit has been upgraded from an 8 bit to a 16 bit

    processor for greater sensitivity. All adjustments and calibration are performed from the front panel, allowing the

    enclosure to remain closed. Password protection prevents unwanted entry. Adjustable frequency allows you to select an operating frequency that is not

    affected by RF noise. Two or more units can be synchronized to eliminate crosstalk. RS-485 is standard with each unit. This allows Modbus communications with a

    remote front panel terminal that is located outside a hazardous area.

  • 122

    Ramsey Oretronic IIIFeatures and Benefits

    Speed pick-up input is available. This will allow the display to show the distance to the tramp in tenths of feet.

    A light stack is available which has red, green and amber lights stacked one on top of another to indicate control status.

    All other options previously available are still offered. Clip Detector High Pile Detector Custom Contoured Coils Spray Marker System Mechanical Flag Drop Alarm Horn Rotating Beacon Light Stack (New)

  • 123

    Ramsey Oretronic IIIFront Panel Display

  • 124

    Magnet

    Control

    Coils

  • 125

    Class II TMD

    Coal

  • 126

    TMD Control

  • 127

    Ramsey Oretronic IIISingle Coil System

  • 128

    Under Belt TMD